Aerona Air Source Heat Pumps



Similar documents
Installation & User Instructions

SWIMMING POOL HEAT PUMP Owners Manual

HP switch LP switch Discharge thermo Comp. Surface thermo

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions

User Manual THR840DUK Digital Thermostat

PANASONIC TROUBLE SHOOTING GUIDE

Air Source Heat Pump Installation and Maintenance Manual Combi Hybrid

ELECTRIC CENTRAL HEATING FLOW BOILER

DC1100 & 1400 Energy Controllers. Satchwell DC1100 & DC1400 for energy-efficient temperature control in smaller buildings.

Drayton Digistat +2RF/+3RF

Vertical Display and Storage B SKOPE Gen2: Three Door Chiller

Failure code manual. content

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

CM702 PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

INSTRUCTION MANUAL CIRRO MK 3/TYPE 2 MIST GENERATOR

SERVICE MANUAL REFRIGERATION

Operating ambient temperature range: 5ºC to 50ºC Storage temperature range: -30ºC to 70ºC

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

Technical data. Danfoss DHP-A

A Class Air Source Heat Pump User Guide

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

Air Source Heat Pump Installation and Maintenance Manual

Model: AC-S13CG x 2. Model No: AC-S13CGx2.doc Version 1.0

ECOCIAT. Domestic hot water heat recovery unit

, User s Manual

Heating Controller. Building Technologies HVAC Products

SWIMMING POOL HEAT PUMP (THP 55, THP 100, THP 120, THP 170) INSTALLATION AND USER GUIDE

ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL

sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved

For installation guide see reverse of book

USERS GUIDE. LOGIC Combi 24, 30, 35. For installation guide see reverse of book

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

AIR CONDITIONING SYSTEM 1. FFH SPECIFICATION AIR CONDITIONING SYSTEM RODIUS

Installation and maintenance instructions. Danfoss Vent

The NEW Greenstar i. intuitive. innovative. improved performance. installation ease

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

SERVICE MANUAL. Room Air Conditioner Multi Split type Outdoor unit /R410A DC Inverter/

Electrical Systems - IQAN Digital Control System. IQAN Control System Components

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

ELECTRIC POSITION for electric heat, then confirm with Fan Test below.

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

User manual. 086U6297 Rev. 9 EN

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

PRODUCT: WASHER / WASHER-DRYER COMBO MODEL: AW 120 / AW 122 / AW 125 AWD 120 / AWD 121 / AWD 129

Single Channel Loop Detector

RVR Hybrid System Installer Instructions RVR Hybrid System Controller Installation Instructions

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

GUIDE TO AIR SOURCE HEAT PUMPS. Consumer, Specifier, Installer and Merchant guide to Air to water heat pump technology

COMPUTHERM Q7 Programmable, digital room thermostat. Operating Instructions

V94 BULK TAPE DEGAUSSER

DERON Air/Water Swimming pool Heat Pump. CY/DY series for Heating/Cooling. Description

your comfort. our world. User Guide Altherma HT For your new Daikin Altherma high temperature heat pump

User's Instructions. Alpha HE CB25/33 and HE SY25

Is an air source heat pump the right choice for my home? Important information and key things to consider before installing an air source heat pump

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

HERZ-Thermal Actuators

CGC s Hybrid System Loop Control

Application Engineering

Hot Water. Heat pump water heaters. Residential and Commercial R410a

Split Controller. User Manual SM-SS-F 2009/01/04

Operating Instructions DT, PRT, PRT/HW PRT-R, PRT-R2

TSB #: 74 Date: 9/7/2013 HOLDEN VE/WM HVAC & A/C DIAGNOSTIC HINTS

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

Installation Questions

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

USERS GUIDE. LOGIC Heat 12, 15, 18, 24, 30. For installation guide see reverse of book

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

Electric Flow Boiler

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...

Convection Ovens. BX Classic. Models BX4 / FG 189C, BX / FG 158C, BX10 / FG 180C. Operator's Manual

Install Guide CT100. Caution. Caution ENGLISH. disconnect the power supply before beginning work.

MAKING MODERN LIVING POSSIBLE. Wiring Diagram DHP-R.

SWIMMING POOL HEAT PUMP

Portable Air Conditioner

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL SCHEMATIC DIAGRAM EXPLOSION VIEW 16 6

MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM EXPLOSION VIEW 12 6.

BREEAM CRITERIA WATER LEAK DETECTION SYSTEM Type WG2 - CONTROL PANEL CONNECTIONS

Heat Pump Water Heater IOM Manual

1 General information

To suit Daikin FDY "F" Series and FD "F" Series. (and other models incorporating BRC1B62/52 Remote Controller)

HVAC-32A. Operation Manual. Specifications. Digital Multistage Air Conditioning Controller with inbuilt Outside Air Economy function

ABNORMAL OPERATION Error code Display. Specifics Error Code. Subsection Error Code. Subsection and Specifics Error code target

ES-LCD User Control SD Card Location

REMOTE CONTROL MANUAL

2 Wire Electronic Time Delay Switch. 2 Wire Slave Switch. 3 Wire Electronic Time Delay Switch

WATER SOURCE / GEOTHERMAL COOLING HEAT PUMP

Fused Spur Time Switch

Table of Contents. 1 - Specifications Installation Wiring User controls...7

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date Rev.

Installation Guide for Hive Active Heating

BoilerMate SP. benchmark. user instructions A - C L A S S

Install Guide 3M-50. Caution. Caution

Monitoring Network DMN

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

HP UPS R1500 Generation 3

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss heating

Transcription:

ADDENDUM to INSTALLATION INSTRUCTIONS for Aerona Air Source Heat Pumps DOC.87-05/05 Rev.04 March 2013 ATTENTION INSTALLERS - UPDATED INFORMATION! Your Grant Aerona Air Source Heat Pump has a number of recent changes that differ from the Installation Instructions supplied with the unit. These changes are part of our continued product improvement process. Please read this Addendum and use the information in conjunction with the corresponding sections of the Installation Instructions (as indicated below). After commissioning, please leave both the Installation Instructions and this Addendum sheet with the user for future reference. Page 2 2.1 Specifications Model HPAW65 HPAW85 HPAW110 HPAW130 Heating Capacity kw 6.9 8.4 10.9 12.3 Nominal running current* A 9.1 10.7 14.0 16.1 COP @ air7 C/water 35 C 3.8 3.8 3.91 3.93 Sound press level @ 1metre db(a) 49.2 50.0 49.0 58.5 Please note that model HPAW155 is no longer available *Does not include operation of 3kW back-up immersion heater Page 2 &3 2.2 Dimensions Model HPAW65 HPAW85 HPAW110 HPAW130 Height (includes legs) mm 790 1040 1040 1040 Width mm 1120 1120 1120 1120 Depth (front to back) mm 430 430 430 430 Height of legs mm 125 125 125 125 Please note that model HPAW155 is no longer available Note: The support legs have been shortened reducing the overall height of the unit by 125mm. There is a security eye on the rear right hand leg for extra security if required. Addendum Aerona Install Instructions Doc.87-05/05 Rev04 11/03/13 Page 1 of 8

Page 5 2.6 Heat Pump Operating Sequences The operating sequence has been altered such that the fan does not start immediately when there is a demand for the heat pump to operate. There is a delay of 60 seconds before the fan starts, with a further delay of 15 seconds before the compressors starts, as shown in the sequence diagram below. Page 7 3.1 Position The drip tray, fitted to the underside of the heat pump, can now be extended by up to 185mm at the rear of the unit to ensure that all water falling from the base of the unit drips into the drainage channel and not onto the concrete slab on which the unit is standing. To extend the drip tray: Remove the two screws (at either end of the drip tray), pull out the extension, re-fit and tighten the screws. Ensure the edge of the drip tray extends beyond the concrete slab, i.e. over the drainage channel (refer to Figure 3-1 in the Installation manual). Page 19 Electrical Installation Requirements Nominal MCB Maximum Minimum Model running Earth Loop Cable size Rating (A) Type current (A)* Impedance (Ω) mm² HPAW65 9.1 32 C 0.72 6 HPAW85 10.7 32 C 0.72 6 HPAW110 14.0 32 C 0.72 6 HPAW130 16.1 45 C 0.46 10 *Does not include operation of 3kW back-up immersion heater Addendum Aerona Install Instructions Doc.87-05/05 Rev04 11/03/13 Page 2 of 8

Page 20 Section 8 - Electrical New electrical control panel and connection layout S-Plan control system terminals Commissioning link terminals Power supply terminals Commissioning connection link There is now a Commissioning link connection located in the control panel. When a wire link is connected between these two terminals, the weather compensation function of the BTC is overridden, allowing the unit to be commissioned under all weather conditions. IMPORTANT: After commissioning, REMOVE the link. Failure to remove the link will result in the BTC weather compensation function NOT operating. Commissioning link terminals Addendum Aerona Install Instructions Doc.87-05/05 Rev04 11/03/13 Page 3 of 8

New Control PCB This new PCB operates exactly as the previous version. The main difference is the use of push-on edge connectors, allowing easier removal and replacement of the PCB if required. New PCB with edge connectors shown in place Key to PCB Connections (refer to photograph above) 1. Neutral 18. Return Gas Temperature Sensor 2. Live 19. Coil Temperature Sensor 3. Crank Case Heater 20. Flow Temperature Sensor 4. High Fan 21. Return Temperature Sensor 5. Low Fan 22. Ambient Temperature Sensor 6. 4-way valve solenoid 23. GND 7. Compressor Relay 24. GND 8. Live Feed In 25. Reserved 9. Drip Tray Heater 26. Reserved 10. Link 27. LP switch 11. Immersion Element 28. HP switch 12. Circulation Pump 29. Link 13. Live Feed In 30. Link 14. ATC connection 31. Commissioning Link 15. GND 32. 12V AC connection 16. Reserved 33. 220V AC connection 17. Discharge Gas sensor Addendum 1. Aerona Neutral Install Instructions Doc.87-05/05 18. Return Rev04 Gas 11/03/13 Temp sensor Page 4 of 8 2. Live 19. Coil Temp sensor 3. Crank Case Heater 20. Flow Temp sensor

Page 30 11.2 Setting the ATC Controller The standby setting, and the corresponding symbol, referred to in this section of the Installation Instructions is no longer present on the latest version of the ATC Controller. The control will always be in the AUTOMATIC setting, and the corresponding will be visible at the top of the display, provided that the unit is switched ON. symbol The main purpose of the ATC controller is to give an overall maximum temperature control over the heat pump. In contrast, the BTC controller will give accurate control over both CH and HW temperatures, even if they each have different target temperatures. The ATC controller must be set to either OFF or AUTOMATIC as follows: 1. OFF This is indicated when NO temperature reading is shown in central section of the display. In this setting the heat pump will not operate irrespective of any demand from either the heating system controls or the BTC controller. Note the at the bottom. symbol will still be visible at the top of the display and the time will be shown To switch heat pump ON Press the button. The flow and return water temperature will appear on the display and the heat pump will start. To switch the heat pump OFF Press the button. The Flow and Return water temperature will disappear from the display and the heat pump will stop. Addendum Aerona Install Instructions Doc.87-05/05 Rev04 11/03/13 Page 5 of 8

2. AUTOMATIC This is indicated when the symbol is visible at the top right of the display. In this setting the heat pump is in a fully automatic condition (provided it is switched ON see 1 above). Functions including normal running, defrosting, and frost protection are all operational. Setting the ATC clock function For the heat pump to operate correctly, the clock function of the ATC must be correctly set using the following procedure: 1. Press the SET button. The hour segments will flash. Alter the hour setting using the buttons. 2. Press the SET button again and the minute segments will flash. Alter the minute setting using the buttons. 3. Press the SET button to confirm the time setting. The clock is now set. NOTE - If no button is pressed for a period of 10 seconds, the ATC will automatically revert back to normal operation. Setting the ATC parameters: In order for the heat pump to operate correctly, the ATC operating parameters must be set as indicated in the table on page 31. IMPORTANT Please note that ALL operating parameters MUST be checked during commissioning and, if not correct, set to the value given in the table on page 31.TANT ITANT31. Incorrectly set parameters will adversely affect the operation and efficiency of the heat pump and will invalidate all warranties. To check the parameter settings, press either of the buttons to enter the list of parameters. Then repeatedly press either of the buttons to scroll through the different parameters. Check the setting of each parameter against the correct values listed in the table on page 31 of the Installation instructions supplied with the ASHP. IMPORTANT Only set the parameters as shown in the table on page 31 unless instructed otherwise by Grant UK. To alter the setting of any parameter, press the SET button once, then use the buttons to alter the value of that parameter. Once set correctly, press the SET button to exit back to the parameter list and continue to check settings. To exit the parameter list stop pressing the the normal operation. buttons. The ATC will automatically return to NOTE - If no button is pressed for a period of 10 seconds, the ATC will automatically revert back to normal operation. Addendum Aerona Install Instructions Doc.87-05/05 Rev04 11/03/13 Page 6 of 8

Page 31 11.3 Additional Operating Information about the ATC Fan Motor Operation With Parameter A set to either 0 or 1; the fan operates at a single constant speed, as follows: a) When in heating mode (CH or HW), the fan motor starts after 60 seconds and the compressor then starts 15 seconds later. b) During defrosting, the fan motor does not operate. Circulating Pump Operation In all conditions, the circulating pump will operate when the ambient air temperature falls below 0 C. This is part of the frost protection and cannot be adjusted by the installer or user. Electric Immersion Heater The electric Immersion backup heater will be energised to increase the heat output of the heat pump when: The ATC set to ON and with a demand (for heating or hot water) AND either The ambient temperature is below the Parameter d setting (default setting 3 C) OR The Return water temperature falls to less than Parameter 0 setting (default setting 2 C) The electric Immersion heater will be switched off when the Return water temperature reaches Parameter 1 setting (default setting 47 C). For all Parameter values, refer to Table of ATC Parameters on page 31 of the Installation instructions supplied with the ASHP. Note: The electric immersion element will be energised automatically during the heat pump defrost cycle. Bivalent Systems In a Bivalent system the electric immersion element is disconnected and the switched live for the back-up boiler is taken from the immersion element live terminal refer to Figures 8-7 and 8-11. Thus the back-up boiler will be energised under the same parameters as given above for the electric immersion element. Frost Protection Regardless of whether the ATC is ON or OFF (i.e. when no Temperatures are displayed on the ATC) the Frost protection will operate. When the Return water temperature is equal or less than Parameter 0 (default setting 2 C) AND the ambient air temperature is equal or less than 0 C) the Heat Pump and circulating pump will start. The Heat Pump and circulating pump will remain ON until the Return water temperature is 12 C or greater. NOTE: When the heat pump is operating (as described above) to provide Frost Protection the code PP7 will be displayed on the ATC. This does NOT indicate a fault condition. Trace Heater Operation The trace heater will be switched on when the ambient air temperature falls to 7 C or below. This is automatic and the temperature non adjustable. Addendum Aerona Install Instructions Doc.87-05/05 Rev04 11/03/13 Page 7 of 8

Addendum Aerona Install Instructions Doc.87-05/05 Rev04 11/03/13 Page 8 of 8