Trapped Key Interlocks for. Switchgear. Applications Guide. www.castell.com



Similar documents
Trapped Key Interlocks

Heavy Duty Solenoid Controlled Access Lock. User Manual - Original Language Version

The following components are common to most cubicles; this example is an ABB HK cubicle.

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

How To Choose A Transformer

Advantages of Fixed Circuit Breaker Switchgear

Low Voltage Switchgear

Cam switches. Page. Overview 4-2. ON-OFF switches, main switches, maintenance switches 4-3. Changeover switches, reversing switches 4-5

Eaton Safety & Reliability Solutions in the Oil & Gas Industry Electrical

Ralf Christian, CEO Low and Medium Voltage. Making Things Right with Totally Integrated Power (TIP)

What will MV switchgear look like in the future? by Jean-Marc Biasse

e 2 ALPHA Medium Voltage Switchgear Data Sheet K EN

MEDIUM VOLTAGE SUBSTATION PRACTICES Medium Voltage (MV) is defined as: 1000V< MV 44kV

Chapter 1. Network Structures

Emirates Aluminium starts up World s first fully integrated power distribution system from ABB

Product brochure Multi Functional Switchgear PASS M kv Flexible and compact switchgear solutions for windfarms

ELECTRICAL INSULATION TESTING OF HV EQUIPMENT UP TO 33kV

High Voltage (HV) Electricity System Safety Rules and Associated Safety Guidance

For a phase-to-phase voltage between 100 V and 1000 V. The standard ratings are: 400 V V V (at 50 Hz)

GE Power Controls. MiniFORM Switchboards

NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements

Secondary Unit Substations

The complete guide to Low Voltage switchgear

Power products and systems. Intelligent solutions for power distribution Zone concept

Arc Flash Mitigation. Remote Racking and Switching for Arc Flash danger mitigation in distribution class switchgear.

Bypass transfer switch mechanisms

The Intelligent AX1 Switchgear for Medium Voltage

Electrical Distribution Services for Mining and Metals Industries

Circuit Breakers and Switchgear. Thomas Greer Director of Engineering TLG Services

SENTRON Switching and Protection Devices Air Circuit Breakers

Low Voltage Switchboards The Best Technical Solution for Your Ship

Paralleling Switchgear

The Application of Circuit Breakers to Reduce Downtime in Datacentres

Electrical Shore Connections / Cold Ironing

MV vacuum circuit breaker Evolis. When trust guides your steps

Nothing s BetterThan the Original MODAN Power Distribution Systems

Earth Fault Detection Basics in Theory

Suitable for Emergency, Peak and Prime Power System Applications. Low Voltage Automatic Transfer Switch Systems

21 st Century Facilities

Understanding Arc Flash

INTERNATIONAL POWER DISTRIBUTION CONGRESS CIDEL ARGENTINA 2002

New standardized approach to arc flash protection

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

Which switchboards equip your building facilities for the future?

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE

Modular Systems, PPMV, 2014 UniPack-G Glass Fiber Reinforced Polyester Compact Secondary Substation

Product overview brochure. ABB Medium Voltage Products Our one-stop approach for every medium voltage application

MV, HV AND EHV SWITCHGEAR TESTING & COMMISSIONING

SURGELOGIC TVSS Surge Protective Devices Enhance System Protection and Reduce Equipment Damage

Products and solutions for pumping, irrigation and piping

Utility generation line card

Intertek Cleeve Road, Leatherhead, Surrey KT22 7SB UK

ANCILLARY EQUIPMENT AND ELECTRICAL EQUIPMENT Power Supply Systems and Electrical Equipment for Desalination Plants - Y.M. Hamud and A.H.

Part 1 System Modeling & Studies for Existing Systems

OPTIMIZING POWER SYSTEM PROTECTION FOR MODERN DATA CENTERS

MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS

How To Understand The Electrical Power Supply Of A Power Supply System

High-Voltage GIS yesterday - today - tomorrow

Type-Tested Power Distribution Board 8PT with Rear Busbars. sivacon

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

WD-AMX Water Detection Controllers

Permissible ambient temperature Operation Storage, transport

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

Data Center Uninterrupted efficiency, guaranteed reliability and continuous modularity. ABB solutions always work.

HYDRO-ELECTRIC POWER PLANTS

Unified requirements for systems with voltages above 1 kv up to 15 kv

SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS. Presented by SAI Advanced Power Solutions

Modular Systems wind portfolio overview Power Collection and Grid Connection products

Arc Flash Mitigation & Selective Co-ordination

DF-DT (G) MEDIUM VOLTAGE SWITCHGEAR THE MODULAR CONCEPT. User Manual. SGC - SwitchGear Company nv - Moorstraat 24 - B-9850 Nevele - Belgium

ESP 120 M1, ESP 208 M1, ESP 240 M1, ESP 415 M1, ESP 277 M1, ESP 480 M1 and M1R variants. Installation instructions ESP M1/M1R mains protectors

Medium voltage products UniSec for Smart Grid Air-insulated medium-voltage secondary distribution switchgear

Tour of new eircom Data Centre Blanchardstown by Dervan Engineering Consultants 11 th March 2015

Low voltage systems for all applications

Phase Attribute Identification using GPS Technology

Circuit Electrical Testing

Emergency Power System Services Industrial UPS, Batteries, Chargers, Inverters and Static Switches

Houston Service Center Medium Voltage Service and Aftermarket Solutions

Medium Voltage (MV) & High Voltage (HV) Training Module 6. Date of the presentation

UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution

CURRENT TRANSFORMERS INSTALLATION GUIDE

Requirements for Offshore Grid Connections. in the. Grid of TenneT TSO GmbH

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...

Extend the Life of Existing Switchgear

Products and solutions for lifting systems

GROUP OF SPANISH ELECTRICITY COMPANIES FOR STUDIES ON IEC 61850

CAPACITOR BANK TESTING SWP

ABB Inc. April 19, 2011 Slide 1

Low and Medium Voltage Division Erlangen, February 18, New MCCBs for Increased Line Protection and Availability

SELECTION OF FINAL CIRCUIT PROTECTION

Technical information. Typical Automatic Transfer Switch diagrams

Fusible Disconnect Switch

2008 Eaton Corporation. All rights reserved.

Electrical Engineering

Paper on Basbar Trunking System for Electrical Supply to Industrial & commercial Installation

Medium Voltage Distribution FLUVAC. Vacuum Circuit Breaker Up to 24 kv 630 A 21 ka. Operation Maintenance Instructions.

ABB s Disconnecting Circuit Breakers Higher substation availability and lower environmental impact

PRE COMMISSIONING TESTS ON EQUIPMENT AT 33/11 KV SUB STATIONS

Transcription:

Trapped Key Interlocks for Switchgear pplications Guide www.castell.com

London Chicago Cologne Shanghai Castell Offices Castell Installations We Keep You Safe at Work Worldwide

Switchgear pplications Guide Contents Why Choose Castell Interlocking Switchgear How to Design an Interlock System Incomer Interlocking Incomer and Busbar Interlocking Incomer, Generator and Busbar Interlocking Transformer Interlocking Power Factor Correction Equipment/Capacitor Bank Interlocking Wind Farm UPS (Uninterruptable Power Supply) Electrostatic Precipitators (ESP) OEM Equipment Switchgear Symbols Products Overview 4 5 6 7 9 10 10 11 12 12 13 14 17 18 While every effort has been made to ensure the accuracy of the information provided, no liability can be taken for any errors or omission. Castell Safety International Limited reserves the right to alter specifications and introduce improvements without prior notice. www.castell.com

Why Choose Castell? Founder: James Harry Castell 1880-1953 Castells Expertise in Industrial Safety The original Castell interlock concept dates from 1922 and was developed for the electrical switchgear industry. For over 90 years Castell delivers solutions across the electrical network from power stations to transmission equipment and from sub stations to incomer rooms. The ability to work across HV, MV and LV means that a Castell system can be used as a single solution to provide personnel safety and ensure equipment is used in the correct mode. Working closely with key switchgear manufacturers has enabled Castell to produce interlocks designed specifically for use on the leading manufacturers own breakers, isolators, disconnectors and earth mechanisms. That makes Castell trapped key interlocks be the perfect choice for protecting personnel in the switchgear environment. Castell Offers: Expertise in providing the best possible trapped key solution whatever the industry 90 years of experience protecting people and assets in industry High quality innovative products ISO 9001: 2008 accreditation Global team dedicated to providing technical support and assistance in selecting the correct solution The widest range of rugged and reliable trapped key interlock products globally The ability to produce customised solutions to meet the demands of your specific application Safety solutions that last for decades - 4 - www.castell.com

Interlocking Switchgear Interlocking Switchgear Interlocking switchgear ensures that personnel remain safe and equipment is operated to the correct procedures. Using a well-designed interlocking scheme will ensure that personnel cannot access potentially dangerous areas without the switchgear system being put in a safe state. good interlocking scheme will also ensure that the system operates correctly and there is no chance of, for example, switching two incoming feeds on to a common bus bar. This ensures that the equipment is not damaged and the risk of fire and arc flash are greatly reduced. Processes where interlocking in switchgear are particularly relevant are: Personnel access Earthing systems High, medium and low voltage hazards Switching incomers on to common supply busbars Switching UPS systems and generators on to common supply busbars Controlling the supply from multiple incomers The schemes in this application guide are for reference only and the overall system should be designed and reviewed by a competent electrical engineer. Castell products are used in the following areas: LV Distribution & Busbar Systems HV Transmission & Distribution Sub Stations Transformer Isolation & Earthing Systems Generator Systems Wind Turbine Isolation & Earthing Rail Electrification Systems Electrostatic Precipitators UPS Systems Castell has developed products to suit the following companies equipment: BB I lstom I Terasaki I Schneider Electric I Siemens I Hawker Siddeley I George Ellison I Merlin Gerin - 5 -

Trapped Key Interlocking How to design an interlock system? Through development and experience Castell have a number of methods to isolate switchgear. This can be done mechanically, through control circuitry or through power circuitry. In complex operations a number of isolations may need to occur to ensure the plant is safe to work on. The isolation key(s) are then used to either gain direct access, are transferred to a time delay unit or for multiple entry points access through an exchange box. The three points of trapped key interlocking 1 Isolation 2 Key Exchange 3 ccess Control ccess and Personal Protection ccess to the hazardous area needs to be assessed as either part body (arm only), or full body access. Once this is determined an access lock(s) can be selected. Part Body ccess part body access lock has only one lock and the isolation key is used to open this. Whilst the access lock is open the key can not be removed and therefore the process can not be started. Only once the lock is closed can the isolation key be removed and the process restarted. Full Body ccess Full body access locks have two locking mechanisms; the first step in the process is to insert the isolation key. This will allow the personnel key to be removed and then access can be granted by opening the bolt. The isolation key can only be removed once the personnel key has been inserted. Therefore whilst the personnel key is removed and the lock is open the process can not be started. Only once the lock is closed and the personnel key returned can the isolation key be removed and the process restarted. Coding a System The coding of the system is an important aspect of the design as this ensures the integrity and safety of the interlocking system. Castell s trapped key interlocks allow for in excess of 50,000 combinations. With this level of available codes entire factories and plants can have trapped key systems with out codes being repeated. It is highly recommended that each site keeps a record of the key codes to ensure that codes are not reused in areas of the site. The isolation, access and personnel keys all need to be coded differently so the process of safe access is ensured. For example in a simple system code is used for isolation key, this is then transferred to the exchange box where the code B keys are released for access, C keys are then released from the ccess Locks for personnel keys. Coding in this way ensures the access process can not be short cut and the system has integrity. - 6 -

Switchgear Interlocking Incomer Interlocking (1) This system will require three locks and two keys. Under normal operation the two keys are trapped with the switches closed so the incomers are supplying. The system will allow an incomer to be opened (disconnected) and the key released. This key is then transferred to the open bus coupler which can then be closed. The system ensures that either only two incomers or only one incomer and the busbar are supplying at any time. The symbols used here are all symbol. * ll locks can be individually fitted to suit the switchgear Incomer Interlocking (2) This system will require three locks and two keys. Under normal operation the two keys are trapped with the switches closed so the incomers are supplying. The system will allow an incomer to be opened (disconnected) and the key released. This key is then transferred to in to the other open incomer which can then be closed. The system ensures that only two incomers are supplying at any time. The symbols used here are all symbol. * ll locks can be individually fitted to suit the switchgear Incomer 1 Incomer 2 Incomer 3-7 -

Switchgear Interlocking Incomer Interlocking (3) This system will require six locks depending on the breakers. One key exchange box and six keys. Breakers and B are closed and the keys are trapped. Keys and B are removed from the breakers when they are opened and inserted into the key exchange box releasing the C keys. The C keys are then inserted in the C locks, closing breakers C. C B B C The symbols used here are, B and C for the incomers. * ll locks can be individually fitted to suit the switchgear B B C C Incomer Interlocking (4) The operation is shown with all incomers closed, the bus coupler open and its key 21 trapped in the W Selector Box. To change to position 1 from normal, incomers with symbols 19 are inserted and trapped in the W Selctor Box. The asterisks denote that incomers three and four remain closed and need not be returned to the box. Key 21 can now be removed to close the bus coupler switch. To change to position 2 from normal, incomers with symbols 20 are opened and their keys are inserted and trapped in the W selector box. The asterisks denote that incomers 1 and 2 remain closed and need not be returned to the box. Key 21 can now be removed to close the bus coupler switch. The symbols used here are 19 and 20 for the circuit breakers and 21 for the bus coupler. * ll locks can be individually fitted to suit the switchgear 21 19 19 20 20 Position Inc 1 19 Inc 2 19 Inc 3 20 Inc 3 20 1 T T F F F Normal F F F F T 2 F F T T F BC 21 * In neighbouring positions only where the key is free in both positions the key does not need to be returned to the key exchange box. - 8 -

Switchgear Interlocking Incomer and Busbar Interlocking (1) This system requires five locks and three keys. In the normal operation the keys are trapped in the incomers in the closed position and both bus couplers are open. The symbol sequence will allow appropriate incomers to be open allowing the key to be released, transferred and inserted and trapped to the associated bus coupler allowing it to be closed. Bus 1 Bus 2 B The symbols used here are, B and BB for the Incomers and _ ( BLNK) and _B (BLNK B) for the bus couplers. * ll locks can be individually fitted to suit the switchgear B BB Incomer 1 Incomer 2 Incomer 3 Incomer and Busbar Interlocking (2) This system will require four locks and two keys. In the situation shown the keys are trapped in incomer one and two with the switches in the closed position. _ Both the bus coupler and incomer three are open. The symbol sequence will only allow incomer 3 or the bus coupler to be closed after the appropriate key has been released, transferred and inserted into the bus coupler or incomer three lock. The system ensures that only two incomers are supplying at any time. B B The symbols used here are and B for the incomers and _ ( BLNK) for the bus coupler. Incomer 1 Incomer 2 Incomer 3 * ll locks can be individually fitted to suit the switchgear - 9 -

Switchgear Interlocking Incomer, Generator and Busbar Interlocking The normal operation is the 2 incomers are closed with bus coupler and generator are both open. The symbol arrangement using key symbols, B, _ ( Blank) on locks with just keys B will ensure safe switching operation. It will not be possible to have Incomer 2 and Generator closed at the same time to avoid paralleling. The symbols used here are and B for the incomers and _ ( BLNK) for the bus coupler. _ G * ll locks can be individually fitted to suit the switchgear B B Incomer 1 Incomer 2 Incomer 3 Transformer Interlocking (1) Whilst the disconnector is on the key cannot be removed. Switching the disconnector to the off position will allow the key to be removed from the K Lock. This key can then be inserted into the K Lock which will retract the bolt and allow the earthing to be switched on. This will in turn allow the key B to be removed extending the bolt and locking the earthing in to the on position. Off Off On Diconnector Disconnector B B B The B key can now we used to gain access through IE. personnel key will be released to ensure that the operation cannot be reversed whilst personnel are in the transformer housing. The symbols used here are for the disconnector and earthing and B for the earthing and the access lock. On Earthing Off Off * ll locks can be individually fitted to suit the switchgear - 10 -

Switchgear Interlocking Transformer Interlocking (2) HV HV LV The HV and LV Isolators are both closed with their respective keys trapped and the transformer door is closed. Both the HV and LV isolators are opened releasing the keys. These keys can then be used in the IE to give access to the transformer. The symbols used here are HV and LV for both breakers. * ll locks can be individually fitted to suit the switchgear Off Off On On Transformer Door On Off On Off HV HV LV LV IE Door Interlock, Double Key Condition Power Factor Correction Equipment / Capacitor Bank Interlocking HV Circuit Breaker When the HV circuit breaker is closed access can not be gained to the PFC equipment as the key remains trapped. When the HV circuit breaker is open the key can be removed and inserted in to the TDI time delay unit. fter a preprogrammed time the B keys are released and these can be used to gain access to the PFC equipment. TDI Time Delay and Key Exchange Unit The symbols used here are for the circuit breaker and B for the access locks. PFC Equipment * ll locks can be individually fitted to suit the switchgear B B I Door Interlocks - 11 -

Switchgear Interlocking Wind Farm When the wind turbine is running and generating electricity the keys are trapped in the HV and wind turbine circuit breaker and access can not be gained to the transformer housing. When the wind turbine and HV circuit breakers are open the keys can then be inserted in to the exchange bow releasing the transformer housing key. This is then inserted in to the I to gain access to the housing. The symbols used here are and C for the circuit breaker and B for the access lock. HV Circuit Breaker B C Wind Turbine Circuit Breaker and Earth Switch C * ll locks can be individually fitted to suit the switchgear UPS (Uninterruptable Power Supply) While the UPS is running, the key is trapped in the KSUPS Interlock. The key can only be turned and released when the UPS is put into Bypass. This will energise the solenoid via a remote signal from the UPS system. Turning the key changes the condition of the switch and released the key, which can now be transferred to the IE access interlock. This allows access to the UPS for maintenance. The UPS will remain in a safe state until the key is returned from the IE and inserted back into the KSUPS and trapped. This allows the UPS to be returned to service. UPS Bypass Supply UPS Load IE ccess Interlock B * ll locks can be individually fitted to suit the switchgear KSUPS Solenoid Controlled Switch - 12 -

Switchgear Interlocking Electrostatic Precipitators The precipitator environment is a very harsh environment in terms of exposure to the elements and the risk that precipitators present with electrodes carrying in excess of 10,000 volts. The process for isolating precipitators is to firstly isolate the circuit breaker, this will then allow the removal of the circuit breaker key. The circuit breaker key is then used to isolate the transformer, when the transformer is isolated the circuit breaker key remains trapped, therefore preventing the circuit breaker returning to the live state. Locking the circuit breaker key in the transformer allows the removal of the transformer key B. The transformer key B is then used in an exchange box. The exchange box allows multiple keys C to be released so access can be gained to multiple areas. These keys can only be released when the transformer key is locked in position. When access is gained the keys from the exchange box remain trapped in the access locks, this effectively ensures that no power to the electrodes can be turned on whilst access is gained. To turn on the circuit breaker the process is simply reversed. In this example the circuit breaker key is symbol, The transformer is symbol and B and the access keys are all symbol C. Circuit Breaker Transformer B Key Exchange Box B C C C ccess Doors Interlocks C C C * ll locks can be individually fitted to suit the switchgear - 13 -

OEM Equipment BB E Max PDS01388(S) BB SCE Megamax Range F1-F2 PDS000800 OES/OETL K-FSB-6.4-3 Eaton Eaton OM Breaker Sovereign Range SMM300 MEM 63-200 MEM 315-800 Magnum C-H-OM FS1B-CW-65 FS1S-CW-65 K-FSB-0-1 K-FSB-6.4-4 K-FSB-12.7-1 PDS02499 FS1B-CW-65-9.5-22 GE GE M Pact ir Circuit Breaker FS1B-CW-45-9.5-22 (post 1996) Harvey Hubble Harvey Hubble Isolator Handle K-FSB-6.4-4 - 14 -

OEM Equipment MEM MEM Glasgow Glasgow K-FSB-6.4-4 Mitsubishi Mitsubishi CB Moulded Case CB FS1B-CW-65-9.5-22 CL1157 Moeller Moeller NZM 7/10/12 (H)=K K-FSB-12.7-1 Terasaki Terasaki R8240 XFH34-RO-3D5 XS400NJ MCB (ext Handle) T6-T40 FS2B-CW-90-9.5-22 K-FSB-13.5-3 K-FSB-13.5-3 FS2B-CW-65-STD - 15 -

OEM Equipment Socomec Socomec Fuser Monobloc Fuserbloc Modular 32-400 S3 Mono Bloc 800 Type 3620-3121 K-FSB-6.4-3 K-FSB-6.4-4 K-FSB-6.4-4 FS1B-CW-65-9.5-22 + Locking lever STD-LEV K-FSB-6.4-4 Siemens Siemens 3WT 3WL MCCB - 3VF6 & 3VF8 FS2B-CW-65-9.5-22 (Braised Body) FS2B-CW-65-9.5-8 (Braised body) K-FSB-16-1 Schneider Schneider NT & NW Chasis Withdrawable Compact NS630b-1600 Chasis Locking Withdrawable Masterpact Compact NS630b-1600 Compact NS100-630 Compact NS NW CL1062 CL1019 CL1062 CL1019 CL1019 K-FSB-0-4 K-FSB-0-4 CL1019 CL1019-16 -

Switchgear Interlocking Common Switchgear Symbols G Contacts closed Contacts open Transformer Breaker Generator FS Lock, key free FS Lock, key trapped I ccess Interlock IE ccess Interlock, personnel key trapped K Bolt Interlock KSUPS Solenoid Controlled Switch Key Exchange Box TDI Time Delay Interlock - 17 -

Products Overview Control Switching KS Solenoid Controlled Switching KSUPS + Time Delay Interlocking TDI Mechanical Isolation FS / Q K Key Exchange Boxes X Y Z W Part Body ccess I Full Body ccess IE - 18 -

Notes - 19 -

CSI-CB/SWG-2013-EN Issue 1 Castell Safety International The Castell Building 217 Kingsbury Road London, NW9 9PQ uk Castell Safety International Oskar-Jäger-Straße 137 50825 Köln Germany Castell Interlocks 150 N Michigan venue Suite 800 Chicago IL 60601 US Castell Safety International Building 1, No. 123 Lane 1165 Jindu Rd Shanghai, 201108 China t: +44 (0)20 8200 1200 f: +44 (0)20 8205 0055 t: +49 (0)221 169 47 94 f: +49 (0)221 169 47 95 t: +1 (312) 360 1516 f: +1 (312) 268 5174 t: +86 (0)21 6151 9028 f: +86 (0)21 6151 9030 uksales@castell.com www.castell.com vertrieb@castell.com www.castell.com ussales@castell.com www.castell.com chinasales@castell.com www.castell.com ISO 9001 Q 10297 While every effort has been made to ensure the accuracy of the information provided, no liability can be taken for any errors or omission. Castell Safety International Limited reserves the right to alter specifications and introduce improvements without prior notice.