Loop-V4300 MINI DACS E1/ T1 CONVERTER



Similar documents
Loop-IP6700 TDMoEthernet

Loop-IP6700 TDMoEthernet

TDMoEthernet. Description

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

Loop-IP6510 Multiple WAN Router/Bridge

Loop-IP6702 TDMoEthernet

DataSMART 554 & 558 T1/FT1 Plug-in DSU/CSUs Page 1 of 8. T1/FT1 Single-port Plug-in DSU/CSUs

VCL-MX Version 6 DXC 80 T1, 120Mbps Digital Access Cross Connect Switch. System Guide. VCL-MX Version 6 - T1 120Mbps Voice & Data Multiplexer

Optical Product Families

T1/E1 High-Speed WAN Interface Card for Cisco 1861 Router

DXC Family. Multiservice Access Node FEATURES

LOOP-H 3300 MULTI RATE G.SHDSL DATA TRANSPORT USER'S MANUAL (Stand Alone - E1/ T1)

WEB RANger-II Internet Access Router

F2400 FOM II Series Fiber Optic Modem Technical Manual

Chapter 4 T1 Interface Card

RICi-E1, RICi-T1 Fast Ethernet over E1/T1 Intelligent Converters

AM3440-A/B/C Access Mux. Description. Features

FCD-E1LC, FCD-T1LC Managed E1/T1 or Fractional E1/T1 Access Units

Cisco 4-Port Clear Channel T1/E1 High-Speed WAN Interface Card

SOLUTIONS FOR AN EVOLVING WORLD. T1/E1 and C Fiber Service Units

Cisco 4-Port Clear Channel T1/E1 High-Speed WAN Interface Card for Cisco 2821, 2851, and 3800 Series Integrated Services Routers

Cisco Channelized T1/E1 and ISDN PRI Modules for the Integrated Services Routers

DataSMART 681, 696 and 698

Cisco Channelized T1/E1 and ISDN PRI Modules

ORION TELECOM NETWORKS INC. T1

Cisco Channelized T1/E1 and ISDN PRI Modules for the Integrated Services Routers

FOMi-E3, FOMi-T3 E3, T3, and HSSI Manageable Fiber Optic Modems

FCD-IP E1/T1 or Fractional E1/T1 Access Unit with Integrated Router

BLACK BOX. T1/E1 Link Extenders OCTOBER 2007 MT195A-T1 MT196A-E1

Configuring E1 and T1 Interfaces

IPmux-1E TDM Pseudowire Access Gateway

Optimux-134, Optimux-125

Megaplex-2100/2104 Modules ML-1/2E1/T1, MLF-1/2E1/T1

Configuring E1 and T1 Interfaces

Where to buy > See the product page > Data Sheet. E1/T1 or Fractional E1/T1 Modular Access Device with Integrated Router

Optimux-45, Optimux-45L Multiplexers for 21E1/28T1 over Fiber or T3

VALIANT COMMUNICATIONS LIMITED

DXC-8R/10A/30 Multiservice Access Nodes

SOLUTIONS FOR AN EVOLVING WORLD IMUX 2000 T1/E1 MDACS. Cross-Connect Switch IMUX 2000 T1/E1 1

Optimux-134, Optimux-125

High-density rack with SNMP management provides E1/T1 and Ethernet services over copper and fiber. Data Sheet

T1 Backhaul Connectivity Solution All Products :: Application Note

How To Connect A G.711 To A G711 Network With A Gbnet (G.723) (Gbnet) (Geo) (Ipnet) And Gb Net (G723.1)

CAMPUS-RS CSU/DS-1 INTERFACE CARDS

24-Port Channelized E1/T1 Line Card Overview

SOLUTIONS FOR AN EVOLVING WORLD IMUX T1/E1 Multiplexer. with common logic redundancy IMUX 2000 T1/E1 1

2-Pair. Managed SHDSL Ethernet Extender. User s Manual

Optimux-34, Optimux-25

FCD-E1E Managed E1 and Fractional E1 Access Device

Cisco 8-Port Channelized T1/E1 Shared Port Adapter

T3 Module USER MANUAL. Part Number L1 / L1

Cable Specifications. T3 Trunk Cabling APPENDIX

Long Range Ethernet Extender

Product Overview. Features CHAPTER

VCL-PRI ISDN VALIANT COMMUNICATIONS LIMITED. Primary Rate (Euro-ISDN) Multiplexer. Product Brochure & Data Sheet

FCD-IP E1/T1 or Fractional E1/T1 Access Unit with Integrated Router

Loop-IP6416 IP-IMUX. Description

Loop Telecom. Total Access Solutions for Enterprise Network, Cellular & Gateway Operator.

E1/T1 or Fractional E1/T1 Access Unit with Integrated Router

TrueAlarm Fire Alarm Systems

T1 Networking Made Easy

Adit 600 Product Guide

T3 Mux M13 Multiplexer

Setting Up and Testing the MAX Hardware

CTC Union Technologies Co.,Ltd. Far Eastern Vienna Technology Center (Neihu Technology Park) 8F, No. 60 Zhouzi St., Neihu, Taipei 114, Taiwan

Dialogic DSI Signaling Web Services Based on Dialogic DSI SS7G41 Signaling Servers

Updated March 2013 UCC Ensuring the Reliability of the Electric Power Grid. T1/E1 Multiplexer with Common Logic Redundancy

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

G.703 Fractional T1 Access Unit. User Guide

SHDSL LAN EXTENDER H301A. User Manual

Product Specifications

Cisco Packet-over-T3/E3 Service Module

ENGINEERING SPECIFICATIONS SENSAPHONE IMS-4000

ZC-24DO CANopen I/O Module: 24 Digital Outputs

T200, PTP/IEEE 1588 Grandmaster Clock and

VALIANT COMMUNICATIONS

Optimux-1551 Fiber Multiplexer for 63E1/84T1 over STM-1/OC-3

Cisco Model EPC2100 EuroDOCSIS 2.0 Cable Modem

Office of Integrated Security Systems Longwood University Camera System Standards

BROADCAST Trasmettitori / Transmitters DBH3 GAP FILLER

Appendix A QUICK Specifications

Total Access SHDSL T1/E1 Line Terminating Unit Installation and Maintenance Practice

Dialogic DSI SS7LDH4 Network Interface Board

Uninterruptible Power Supply

TrueAlarm Fire Alarm Systems

DATA SHEET TESirAFOrTÉ Ai TESirAFOrTÉ AVB Ai

T-BERD 107A. T-Carrier Analyzer

Unidirectional Transmitter/ Receiver Units Introduction

FlexPoint T1/E1 Copper to Fiber Line Driver

Optimux-1553 Fiber Multiplexers for 3 E3/T3 over STM-1/OC-3

Environmental data Temperature: -20 C to +55 C (Operating) -55 C to +85 C (Storage) Humidity: 0 95%

Cisco Model DPC3010 DOCSIS 3.0 8x4 Cable Modem

Loop-V4300 Mini DACS E1/T1 Converter USER'S MANUAL

RC001-4/RC002-4 (REV.B) 4-slot rack mounted chassis User manual

Transcription:

MINI DACS Loop-V4300 MINI DACS / CONVERTER Description Loop-V4300 Mini DACS / converter provides both DS0 and n x 64 Kbps cross-connect between any and ports and to format conversion functions. to conversion include line format, A law toμlaw conversion, and signaling bits association. Loop-V4300 also supports a port operating from 56 Kbps to 1984 Kbps, This unit is suitable for applications involving 2 or 4 ports. Loop-V4300 also supports inband Management, where management data is carried in a DS0 time slot, the same way as user data, traversing national networks. Features : 2, 3, or 4 ports,,, or (2 Max.) For /, each DS0 time slot from any port can be assigned to any DS0 time slot of any other port For /, each DS0 can be designated as a 64 Kbps clear channel, or as a voice channel. Full translation of digitized voice between and, including A law to μ law and signaling bits association. 2-line by 16-character LCD for maintenance, performance monitoring, and administration Ethernet port for the connection to SNMP and to Telnet Inband Subnet Management facility for remote management through national networks. Multicolor LED indicators for each of 4 line interfaces CERTIFIED ISO-9001

Ordering Information To order specify: Note: RoHS compliant units are identified by the letter G appearing immediately at the end of ordering code. Model (non RoHS compliant) Model (RoHS compliant) Description Loop-V4300-AA-BB-CC-DD- SNMP-pp Accessories Loop-V4300-AA-BB-CC-DD- SNMP-pp-G User s Manual (All User s Manuals are RoHS compliant) V4300-UM Power Cord (All power cords are RoHS compliant) Loop-ACC-PC-USA Loop-ACC-PC-EU Loop-ACC-PC-UK Loop-ACC-PC-AUS Loop-ACC-PC-CH Where each AA, BB = E75 for 75 ohm BNC interface port 20 for 120 ohm Twisted Pair RJ48C interface port for interface port Where CC and DD are optional = E75 for 75 ohm BNC interface port 20 for 120 ohm Twisted Pair RJ48C interface port for interface port for V.35 interface port SNMP = pp = User s Manual (paper, hard copy-optional). A CD version of the manual is already included as standard equipment. AC power cord for Taiwan/USA AC power cord for Europe AC power cord for the UK AC power cord for Australia AC power cord for China Ethernet port for SNMP and Telnet connection DC for 20-72 Vdc power source AC 100-240 Vac power source (Please specify which type of power cord you need.) Example: Loop-V4300 --V.35-V.35-SNMP-AC is a unit with one port, one port, two V.35 ports, SNMP, and 100-240 Vac power.

LOOP-V4300 MINI DACS / CONVERTER PRODUCT SPECIFICATIONS Network Line Interface () Line Rate 2.048 Mbps ± 50 ppm Line Code AMI / HDB3 Input Signal ITU G.703 Framing ITU G.704 Connector BNC/RJ48C Output Signal ITU G.703 Electrical 75Ω Coax/120Ω twisted pair Network Line Interface () Line Rate 1.544 Mbps ± 32 ppm Line Code AMI / B8ZS Input Signal DS-1 from 0 db to -26 db w/albo Surge Protection FCC Part 68 Sub-Part D Framing D4/ ESF/ ESF&.403/ NONE (Clear Channel) Connector RJ48C Output Signal DSX-1, DS-1 Pulse Template Per AT&T TR 62411 Interface (V.35) Data Rate n x (56 or 64) Kbps (n = 1-31) Connector DB25S for V.35 Performance Monitor Performance Store : Last 24 hours performance in 15 minutes interval register and last 7 days in 24 hours summary : The last 24 hours performance in 15-minute intervals Monitor Registers : Line, user : Line, user Performance Reports : Reports include Date&Time, Error Second, Unavailable Second, Bursty Error Second, Severe Error Second, Degraded Minutes, and Controlled Slip Second. Also available in Statistics (%) : Reports include Date&Time, Error Second, Unavailable Second, Bursty Error Second, Severe Error Second, Controlled Slip Second, and Loss of Frame Count Alarm History Reports include Date&Time, Alarm Type (i.e. Master Clock Loss, Yellow Alarm, AIS, LOS, BPV, ES, CSS), and Location (i.e. line, PORT A, B, C, D ) Alarm Queue Contains 40 alarm records which record the latest alarm type, location, and Date&Time Alarm Relay Alarm Relay Normally closed Fuse alarm and performance alarm Protection 1 for 1 Port B can be configured to protect Port A Port A can be configured to protect Port B

Network Management Console Port Connector DB9 at Front Panel Electrical RS232 interface Protocol Menu driven VT-100 terminal Ethernet Port Connector RJ45 in rear Protocol Telnet (V00) and Embedded SNMP Voice Channel Conversion A-law to μ-law G.711 Signaling bits ABCD are converted using user configurable conversion table Inband Management Any 64 Kbps DS0 can be assigned for management Management Protocols: HDLC Diagnostics Test Loopback Line Loopback, Payload Loopback, Local Loopback, and Loopback Front Panel Keypad LCD LED 4 keys: left arrow, right arrow, ESC, and ENTER 2-line by 16-character 6: Power, Port A, Port B, Port C, Port D, Alarm Physical/Electrical Dimensions Temperature range Power Fuse Humidity Mounting 212.6 x 43.7 x 197 mm (WxHxD) 0 C -50 C 20-72 Vdc / 100-240 Vac, 50/60 Hz, 10 Watts 250V, 800mA 0%-95% RH (non-condensing) Desk-top stackable, 19/23 inch rack mountable, two units side-by-side

Application Illustrations: A: 2 links B: 3 links C: 4 links A1: / converter (24 TS) B1: / converter (31 TS) and DACS C1: Dual / converter and DACS A2: LTU with B2: / converter and DACS C2: / converter and DACS A3: CSU with B3: DACS C3: / converter and DACS CSU A4: ICSU B4: DACS C4: DACS B: 3 links C: 4 links C5: DACS 1 for 1 Protection / / / / / / / / / / / / / / / / LOOP TELECOMMUNICATION INTERNATIONAL, INC. LoopTelecom.com Worldwide Taipei, Taiwan North America Suzhou China Tianjin China 8F, No. 8, Hsin Ann Road, 2F, No. 40, Section 2, 8 Carrick Road Tel:+86-512-6252-0456 Tel:+86-22-8789-2753 Science-Based Industrial Park Tuan-Hwa S. Road, Palm Beach Gardens Fax:+86-512-6252-7641 Fax:+86-22-8789-0344 Hsinchu, Taiwan 300 Taipei, Taiwan 106 Florida 33418, U.S.A. Sales@looptech.com.cn Loop@loop-tj.com Tel:+886-3-578-7696 Tel:+886-2-2784-4000 Tel:+1-561-627-7947 Fax:+886-3-564-6272 Fax:+886-2-2754-2325 Fax:+1-561-627-6615 www.looptelecom.com jimber561@aol.com sales@loop.com.tw 2006 Loop Telecommunication International, Inc. All Rights Reserved Version 21 12 Dec 2006 Subject to change without notice.