Current opportunities of sprayed waterproofing membrane. Frank Clement Technical Manager Sprayable Membranes MEYCO Global Underground Construction



Similar documents
Solutions for tunneling and mining. Waterproofing. Expanding Horizons Underground. Expanding horizons underground

World Tunnel Congress Underground Facilities for Better Environment and Safety - India

The detailed layout of the system, its technical properties and possible areas of cost-effective use are presented.

constructive solutions Fosroc total waterproofing protection of below-ground structures

ITAtech Activity Group Lining and Waterproofing

SikaProof A Technology

Waterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries

Hanson Building Products. precast basement solutions

Membrane for tunnels and underground construction

WATERPROOFING SikaProof -A TECHNOLOGY

Construction. SikaProof A-08 Edge, A-12 Edge. Fully bonded FPO sheet membrane in L-shape for the SikaProof A waterproofing system. Product Description

Always. Reliable. Tight. Wall sleeves Versatile solutions for building entries. cablepipebuildingentry+

PIPE REHABILITATION. Industrial Wastewater Municipal Wastewater Drinking Water Pressure Pipes

Waterproofing below-ground with Proofex Engage. constructive solutions

Site Inspection Report

HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS

REVIEW OF TRENCHLESS TECHNIQUES FOR THE REHABILITATION OF SEWERS. Gerhard (Gerry) P. Muenchmeyer, P.E. Muenchmeyer Associates, LLC

WATERPROOFING OF WET ROOMS

SIKABIT W-15 WET-BONDED WATERPROOFING MEMBRANE

Specification for tunnelling third edition. The British Tunnelling Society and The Institution of Civil Engineers

After reading this lesson you will be able to: 12.3 IMPORTANCE OF ROOF 12.4 TYPES OF ROOF IN A HOUSE

ARCHITECTURAL TECHNOLGY 4 ADVANCED CONSTRUCTION TECHNOLOGY BASEMENT CONSTRUCTION YEAR 3 SEMESTER 1 AIDAN WALSH R Lecturer: Jim Cahill

WATERPROOFING SikaFuko INJECTION HOSE SYSTEMS UNIQUE WATERPROOFING SOLUTIONS FOR CONSTRUCTION JOINTS

The AQUAFIN Approach to Concrete Repair

Integrated Manhole Ladder System

LAYING BLOCK AND BRICK

WATERPROOFING BASEMENTS

Wecryl Waterproofing System under surfacing supplied by others

WATERPROOFING SIKAPLAN MEMBRANE SYSTEMS FOR BASEMENTS TECHNOLOGY & CONCEPTS

THORO. Waterproofing Systems

Concrete Waterproofing Systems. Integral Protection.

Issue of the Guidelines on Prevention of Water Seepage in New Buildings

Product Systems AQUAFIN-IC CEMENTITIOUS CRYSTALLINE PENETRATING WATERPROOFING. Waterproofing Specification

INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength.

WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12

Waterproofing construction Joints

BLACK JACK ALL WEATHER ROOF COATING

Chapter. Restoration of Damaged Structures

Waterproofing below-ground with Proofex Engage

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

Oil and Gas Pipeline Design, Maintenance and Repair

Sources A recent survey of leaking basements showed water comes from a variety of sources, but walls are the usual culprit: Occurrence of moisture

Fame Design Ltd (10295) Plot # A-115/116,BSCIC Hosiery I/A, Narayangonj, Bangladesh ( , ) 18.June.2014

SECTION STORM DRAINAGE SYSTEM

Building Owners Guide to a Duro-Last System!

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.

Simplifying design and construction. Alan Tovey, Director The Basement Information Centre

SECTION 55 PIPE FOR STORM DRAINS AND CULVERTS (FAA D-701)

A Guide to Structural Waterproofing

Introduction to Pressure Pipe Rehabilitation with CIPP

Remedial Waterproofing of Basement

Highlights. Grace Around the World

ALKALI-RESISTANT WATERPROOFING AND DECOUPLING MEMBRANE UNDER CERAMIC TILES AND NATURAL STONE

SikaBond Adhesive Systems for Floor Coverings. Innovation & Consistency. since 1910

MAPEI s Resfoam polyurethane products

Improving the flood resistance of your home. Advice sheet 6: Flood-resilient floors

Safe & Sound Bridge Terminology

Chapter 2 Basis of design and materials

CORROSION ENGINEERING RESIN-BASED POLYMER CONCRETES AND GROUTS

Waterproofing of Tunnels under Water Pressure

VOLUME V GUIDELINES FOR DESIGN CONSULTANT TABLE OF CONTENTS APPENDIX B: MASTER CONSTRUCTION SPECIFICATIONS AND PREPARATION GUIDE, DIVISIONS 0-10

NEGATIVE SIDE WATERPROOFING SYSTEMS FOR MASONRY AND CONCRETE

INTERIM ADVICE NOTE 96 /07 Revision 1 GUIDANCE ON IMPLEMENTING RESULTS OF RESEARCH ON BRIDGE DECK WATERPROOFING

Complete Waterproofing Protection from Rooftop to Basement. Crack Injection, Joint Waterproofing, Waterproofing Membranes

What you need to know about concrete block basement construction.

Sewer Rehabilitation Design Requirements

INCREASE OF DURABILITY AND LIFETIME OF EXISTING BRIDGES. PIARC TC 4.4 EXPERIENCE.

external Basement waterproofing

Non Destructive Waterproofing Remedial Treatment

COPYRIGHT. Dincel Construction System Pty Ltd

Mold Preventing I nterior System

Mineral waterproof coating PCI Dichtschlämme

External Wrapping of Steel Riser Pipe. Case Study HJ3 CS200902

High Performance PSA in Sheet Membrane in Water Protection

8.7 Schluter -KERDI-LINE

Module 3 : Sewer Material. Lecture 3 : Sewer Material

Puddle Flange. FRANK Puddle Flange

THE ULTRASONIC TOMOGRAPHY TESTS OF CONCRETE IN FOUNDATION SLAB

MULTI-TIGHT 2K. The New Generation for Waterproofing Buildings

G. Common Defects in Buildings - Leakage

external Basement waterproofing

ELASTOCEM. Technical features. Applications. Two-component flexible, waterproofing and protective cementitious grout.

STANDARD SPECIFICATIONS SECTION CLEANING AND LINING WATER MAINS

7. Installation. installation CAST-IN WINDOW SYSTEM 7.1. INSTALLATION OF WINDOW MAIN FRAME

Repair and Rehabilitation of Nehru Memorial College of K.V.G. Group of Institutions at Mangalore - A Case Study

FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING

BELOW GROUND TANKING

ExTERNAL BASEMENT WATERPROOFING

T R A N S F E R A B L E F U L LY

Concrete Repair. Applications and Procedures

Tunnels & Arches OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM

Flexible Waterproofing of Basement Structures with Sikaplan Membranes

The existing roof angle change terminations and flashings when sound and intact can be reused.

HYLINER AKS HDPE LINING

REHABILITATION OF CONCRETE BEAM BRIDGES IN CROATIAN STATE ROAD NETWORK

Rehabilitation of an Aging Concrete Reservoir Adit Tower

Transcription:

Current opportunities of sprayed waterproofing membrane Frank Clement Technical Manager Sprayable Membranes MEYCO Global Underground Construction 1

What would we like to achieve? 2

What is desired? 3

and what is not desirable! 4

Current technology: Conventional waterproofing concept with sheets Widely spread and accepted Installation precision is needed Leakage difficult to repair need for compartments Precise welding Complex geometries are difficult 1st Stage: Sheet Formation 2nd Stage: Application 5 5

Current technology: Conventional waterproofing concept with sheets Installation of traditional waterproofing sheets is a real challenge! 6

Current technology: Conventional waterproofing concept with sheets Temporary sprayed concrete lining Geotextile fleece Waterproofing sheet membrane Permanent cast in situ concrete lining Water ingress through crack in the concrete Unlimited water circulation through fleece behind sheet membrane Possible defects on sheet membrane allow unlimited water circulation behind concrete lining Folding and overstraining of the sheet membrane are possible! Water finds its way into the tunnel 7

Innovative Waterproofing Concept with MASTERSEAL 345 Waterproofing membrane Easy to apply No problem with complex geometry High application rates Easy to repair in case of water ingress. One Stage: Sheet Formation & Application 8 8

Innovative Waterproofing Concept Main Features (1) With MASTERSEAL 345 a waterproof, permanent CSL (Composite Shell Lining)is feasible Higher serviceability: Permanent waterproofing Improved safety and functionality Advantageous especially in complex sections, e.g. crossways Applicable for drained and undrained systems 9

Innovative Waterproofing Concept Main Features (2) MASTERSEAL 345 is compatible with other waterproofing systems, e.g. interfaces with conventional sheet membranes 10

Innovative Waterproofing Concept Main Features (3) Easy and rapid application: 50 100 m 2 /h (2-3 workers) Up to 180 m 2 /h (Robot application) Sheet membranes: approx. 25 m 2 /h Inner lining may also be built with fiber reinforced sprayed concrete Continuous waterproofing: No waterstops required No compartmentalization of sections Application onto bolt heads possible 11

MASTERSEAL 345 chemistry: Polymer Colloid, Emulsion, Dispersion, Latex Small particles from waterinsoluble polymer chains become water-soluble by addition of soap + + + + Polymer Soap Static stabilization occurs: + Polymer + + + 12

Why have we chosen EVA copolymers? EVA is the abbreviation of Ethylene Vinyl Acetate. This film is used in the production of solar panels for the encapsulation of the cells. EVA is hard-wearing, transparent, resistant to corrosion, and flame retardant. 13

Composite Shell Linning: Double bonded concept 1 st layer of permanent sprayed concrete lining Layer of MASTERSEAL membrane 2 nd layer of permanent sprayed or cast concrete lining 14

The fully bonded membrane in a composite SYSTEM Primary Sprayed Concrete Lining Sprayed Membrane Spray-applied membrane 3mm Secondary Insitu or Sprayed Lining MASTERSEAL 345 has same bond on both sides allowing a composite system 15

Innovative Waterproofing Concept CSL and MASTERSEAL 345 Sprayed concrete lining Spray applied membrane MASTERSEAL345 Final concrete lining Due to bonding of the system Water ingress through crack in the concrete no water migration along the interface membrane-concrete Water ingress into the tunnel is usually not possible Eventual local defects can be effectively and quickly repaired, because of easy location of leak! 16

TSCL Cast Insitu TSCL PSCL TSCL Cast Insitu Advances in the design of concrete linings Primary Lining seen as temporary only Primary Lining seen as permanent Benefit from: - Bond - Easy placing of sprayed membrane & sprayed concrete Benefit from: - Bond - Easy placing of sprayed membrane & sprayed concrete - Reduced lining thickness through composite structure Benefit from: Bond and Placing spray. membrane 17

Full advantage of CSL plastic sheet membrane (double welded joints) geotextile fleece temporary sprayed concrete (steel mesh reinforced) permanent support design thickness temporary support design thickness permanent in-situ cast concrete permanent support design thickness primary permanent sprayed concrete (fiber reinforced) secondary permanent sprayed or in-situ cast concrete 18 18

Full advantage of CSL plastic sheet membrane (double welded joints) the saving geotextile fleece temporary sprayed concrete (steel mesh reinforced) permanent support design thickness temporary support design thickness permanent in-situ cast concrete permanent support design thickness primary permanent sprayed concrete (fiber reinforced) secondary permanent sprayed or in-situ cast concrete 19 19

BASF S.E. Asia Private Limited Lausanne M2 Advantage with CSL Original Design Sheet Membrane & 300mm Concrete Contractors Alternative Design Sprayed Membrane & 140+40 mm Sprayed Concrete

Tests to evaluate parameters for CSL 21

Innovative Waterproofing Concept Application Aspects (1) 22

Innovative Waterproofing Concept Application Aspects (2) 23

Innovative Waterproofing Concept Application Aspects (3) Substrate / Concrete surface must be thoroughly cleaned before application of MASTERSEAL 345: Fresh and clean concrete substrate: with water (spraying nozzle) Light dirty concrete substrate / sanding : high pressure cleaning Old, dirty concrete substrate: very high pressure (> 250 bar) Cleaning also with pressurized air and water possible Avoid oil to come in contact with the air flow! Wetting of clean substrate just prior to application good bond 24

Innovative Waterproofing Concept Application Aspects (4) No application on standing water (e.g. tunnel invert)! Pre-treatment of water ingresses before application: Damp spots without visible water ingress: no measures! Running water: temporary stopped (injection) or drained Works must be adapted to local conditions and supervised Drainage measures should be handy and properly fixed on the substrate to avoid vibrations during application 25

Innovative Waterproofing Concept Application Aspects (5) Example of local drainage measures with half-pipe channels fixed on sprayed concrete: 26

Innovative Waterproofing Concept Application Aspects (6) Combination of local pressure relieve measures by means of boreholes (ø 10 mm, L < 1 m) and chemical injection (packers) after curing of MASTERSEAL 345 or application of final lining: 27

References New built tunnel using a CSL design Rehabilitation and upgrading existing tunnel 28

Hindhead A3 6.7 km dual carriageway 1.8 km twin bore tunnel Environmentally sensitive area Overall project cost 371 m Completion in 2011

Primary lining layout Primary lining Flat invert (almost) Heading Groundwater drainage Elephants feet Bench

Primary Lining Top heading Bench 200mm sprayed concrete primary, permanent lining For durability, all steel elements designed out: No lattice girders No mesh No rockbolts Steel / structural plastic fibre reinforced

Base concrete and cross passages

Secondary Lining Value Engineering 1 2 3 1 2 3 4 1. SFRS Primary lining 2. PVC sheet membrane 3. Plain cast in-situ concrete Secondary lining 1. SFRS Primary lining 2. Spray applied membrane 3. Sprayed concrete Secondary lining 4. Plain cast in-situ concrete walls

Spray applied waterproofing

Casting sidewalls

Hindhead State-of-the-art SCL design Key benefits: Same team, same equipment as for SCL 1 2 3 Materials and Equipment Cost saving ~ 1.5M Programme saving 3-4 months Increased flexibility 4 1. SFRS Primary lining 2. Spray applied membrane 3. Sprayed concrete lining 4. Plain cast in-situ concrete lining

Rehabilitation of stone masonry lining Railway tunnel Charnadüras, CH 37 Tunnel Charnadüras Inauguration: 1909 Length: 689 meter

Rehabilitation of stone masonry lining Railway tunnel Charnadüras, CH 38 The two main issues for the rehabilitation: Large deformations and structural instability of parts of the walls caused by ice pressure Minor seepage in the tunnel crown and walls, structural stability ok

Rehabilitation of stone masonry lining Railway tunnel Charnadüras, CH 39 Type 1: Surface rehabilitation in crown and walls Type 2: Complete reconstruction in damaged and deformed areas

Rehabilitation of stone masonry lining Railway tunnel Charnadüras, CH 40 Rehabilitation type 1 - surface damage Situation prior to rehabilitation: Water ingress through joints Partially deteriorated joint filling material (mortar) near tunnel surface In some places: formation of ice during winter

Rehabilitation of stone masonry lining Railway tunnel Charnadüras, CH 41 Rehabilitation type 1 - surface damage Rehabilitation efforts: Abrasive trimming of surface Singular seepage points collected in drainage features MASTERSEAL 345 spray applied membrane Steel fibre reinforced spray concrete 7 cm thickness

Rehabilitation of stone masonry lining Railway tunnel Charnadüras, CH 42 Type 1: Section of system with drainage detail Drillhole to collect seeping water Removal of 7 cm of old lining by abrasive trimming Drainage feature with drainage half-pipe placed in a groove

Rehabilitation of stone masonry lining Railway tunnel Charnadüras, CH 43 Rehabilitation type 2 serious damages rehabilitation: Situation prior to Formation of ice caused pressure and strong inwards deformation of the masonry lining Developing situation, immediate intervention was required Complete reconstruction of these sections

Rehabilitation of stone masonry lining Railway tunnel Charnadüras, CH 44 Rehabilitation type 2 serious damages Rehabilitation efforts: Demolition and reconstruction of old lining in shorter sections Spray applied waterproofing in combination with sprayed concrete and mesh reinforcement

Rehabilitation of stone masonry lining Railway tunnel Charnadüras, CH 45 Rehabilitation type 2 serious damages Demolition of old lining in 3 meter sections step by step Rock support with wet mix sprayed concrete

Rehabilitation of stone masonry lining Railway tunnel Charnadüras, CH 46 Rehabilitation type 2 serious damages Reconstruction: Primary support with sprayed concrete, MASTERSEAL 345 sprayapplied waterproofing membrane and inner lining of mesh-reinforced sprayed concrete Formwork for overlapping joints of the next section 3. Rehabilitation of stone masonry lining Railway tunnel Charnadüras, Switzerland

Rehabilitation of stone masonry lining Railway tunnel Charnadüras, CH 47 Rehabilitation type 2 serious damages Final lining with meshreinforced sprayed concrete

Conclusions Conventional water proofing systems is not always the best solution New concept with MASTERSEAL 345 is allowing CSL which can save risks, time and costs in a project New design approach is necessary when using MASTERSEAL 345 in a composite structure MASTERSEAL 345 has several design options Spray applied membrane is fast, easy and flexible MASTERSEAL 345 has shown its performance in numerous projects worldwide 48