Any potential user should ensure in consultation with the manufacturer that this AMS is suitable for the installation on which it will be installed.



Similar documents
Any potential user should ensure in consultation with the manufacturer that this AMS is suitable for the installation on which it will be installed.

Certificate: / 20 August 2013

Certificate: _01 / 29 April 2014

Certificate: / 20 August 2013

Certificate: / 29 April 2014

Certificate: / 29 April 2014

Certificate: _01 / 9 September 2014

CERTIFICATE. on Product Conformity (QAL 1) Number of Certificate: GM32 ln-situ-gasanalysator model Cross Duct for NO and S02

CERTIFICATE. about Product Conformity (QAL 1) Number of Certificate: _01. TÜV Rheinland Energie und Umwelt GmbH

Approved application The certified AMS is suitable for continuous ambient air monitoring of O 3 (stationary operation).

Certificate: / 9 September 2014

Certificate: / 29 April 2014

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE. on Product Conformity (QAL 1) Number of Certificate: DURAG data systems GmbH Kollaustr Harnburg Germany

CERTIFICATE. on Product Conformity (QAL 1) Number of Certificate: Gaschromategraph GC 5000 BTX Type FID for Benzene

CERTIFICATE. on Product Conformity (QAL 1) Number of Certificate: NIS Ingenieurgesellschaft mbh lndustriestr Alzenau Germany

EN Type Approval & Certification of AMS (QAL1)

Guido Baum Phone: +49(0) Mail:

Performance Standards and Test Procedures for Automated Dust Arrestment-Plant Monitors

Performance Standards and Test Procedures for Continuous Emission Monitoring Systems

EN A new unified testing and approval scheme for automated measuring systems

TÜV RHEINLAND ENERGIE UND UMWELT GMBH

M20. Technical Guidance Note (Monitoring) Quality assurance of continuous emission monitoring systems - application of EN and BS EN

TÜV RHEINLAND IMMISSIONSSCHUTZ UND ENERGIESYSTEME GMBH

DUST EMISSION MONITORING SYSTEM

It s time for H.E.R.O. Energy Saving Strategy for. Tunnel & Shuttle Kilns

Emission Monitoring and Reporting (EMR) Guidelines for Continuous Emissions Measurements in Holcim Cement Plants

S300 Series Dust Monitors


Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

PRODUCT CONFORMITY CERTIFICATE

TransCity Legacy Way Air Monitoring Network

Testing of particulate emissions from positive ignition vehicles with direct fuel injection system. Technical Report

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

SO 3 -Monitoring in Flue Gas of a Power Plant Application & Results

INDUSTRIAL SERVICES PRESSURE EQUIPMENT CERTIFICATION (PED) Pressure equipment certification. Your key to market access in Europe.

Why use Tigerloop in fuel heating systems?

FÉDÉRATION EUROPÉENNE DE LA MANUTENTION Section Industrial Trucks. Information of the application of the EC Regulation on the noise of forklifts

PV module safety qualification according to IEC 61730:2004 EN 61730:2007

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date:

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Overview of Standards for CO Detection Products

Monitoring Air Emissions on Ships. Restricted Siemens AG 2014 All rights reserved.

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

SEISMIC VELOCITY TRANSDUCER T1-40

(a) Method 1 Sample and Velocity Traverses for Stationary Sources.

Holcim Emission and Monitoring (EMR) Manual for United States of America

Online Infrared Flue Gas Analyzer Gasboard 3000

Type testing

PROCEDURE 1. QUALITY ASSURANCE REQUIREMENTS FOR GAS CONTINUOUS EMISSION MONITORING SYSTEMS USED FOR COMPLIANCE DETERMINATION

State of New Jersey. General Permit. For. Boilers and Heaters [Individually Less Than 10 MMBTU/HR]

WELMEC European cooperation in legal metrology

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

Demystifying the European Machinery Directive and SEMI Requirements for the Industrial Automation and Semiconductor Markets

Environmental Automated Measuring Systems for Flue Gas

Application Note 12: TrendView Recorders Continuous Emissions Monitoring

BRANCH SOLUTION. Automatic fire extinguishing systems for paint spraying plants. Safe for certain.

Beräkningar enligt EN 14211, EN 14212, EN och EN

R&S ZNC Vector Network Analyzer Specifications

STATE OF COLORADO PORTABLE ANALYZER MONITORING PROTOCOL

Digital inductive conductivity transmitter

CONTOIL DFM 8EDM. Table of contents. Mounting and operating instructions

Half the cost Half the carbon

Evaluation of mobile storage systems for heat transport. G. Storch, A. Hauer, A. Krönauer ZAE Bayern, Walther-Meißner-Str. 6, Garching, Germany

Technique of Monitoring Dioxins in Flue Gas from MSW Incinerators using Dioxin Precursor Analyzer

Sewage sludge treatment with oxygen enrichement and oxyfuel combustion in CFBC - new pilot plant results

Troubleshooting HVAC/R systems using refrigerant superheat and subcooling

Manual stack emission monitoring Performance standard for organisations. Environment Agency November 2011 Version 7.2

EcoDesign & Labelling Directive (ErP)

Analysis instrumentation EI&C engineering and automation Technical diagnostics. Services FROM THE professionals

Hand-held thermometer Model CTH7000

KNX TH65-AP. Thermo-Hygrometer. Technical specifications and installation instructions Item number 70184

AC Service Equipment ACE 21 EXPERT. Fully automatic service station. R-1234yf refrigerant. Made in Germany

Dewchecker 2.0. Operating instructions. messen steuern automatisieren - messen steuern automatisieren - messen steuern - automatisieren

Feasibility Study for Mobile Sorption Storage in Industrial Applications

R&S ZNBT8 Vector Network Analyzer Specifications

Extract of the White paper Reduce energy costs in compressed air systems by up to 60%

Environmental Equipment, Inc. IMR 5000 Continuous Flue Gas Monitoring System IMR 5000

CHAPTER 3 EXPERIMENTAL SET UP

(Adopted December 1, 1978)(Amended July 8, 1983)(Amended November 6, 2009) (Amended September 5, 2014)

Original instructions Tina 3A/Aps Adaptor unit

2nd IEA Oxyfuel Combustion Conference

AS-i 3.0 Gateways, PROFIsafe via PROFINET or PROFIBUS

I STAR COMPUTER CO., LTD

Rule EMISSIONS OF OXIDES OF NITROGEN FROM LARGE WATER HEATERS AND SMALL BOILERS

J TB/TW Temperature limiter, temperature monitor

Scheme rules for thermal insulation products for building equipment and industrial installations - VDI certification scheme

Certification of the generation of electricity from renewable sources (abbreviated as: Generation EE)

New technical solutions for energy efficient buildings

Control Device Requirements Charts For Oil and Gas Handling and Production Facilities

T7560A,B,C Digital Wall Module

Zero Emission Engine. An Economic and Environmental Benefit

(a) Method 1 Sample and Velocity Traverses for Stationary Sources.

Highly efficient flue gas analyzer

ASME QRO Certification Program

Examination syllabuses for Manual Stack emissions monitoring. Environment Agency Version 9 January 2015

Technical Guidance Note (Monitoring)

TCR easy Plus Alarm. Operating Instructions

IMR 6000/10../20../30

Transcription:

Test report: 936/21206693/B of 28 March 2011 First certification: 29 July 2011 Run of validity until: 28 July 2016 Publication BAnz. 29 July 2011, No 113, page 2725, chapter I, No 4.2 Authorised application The tested AMS is suitable for the use at combustion plants according to EC directive 2001-80-EC, at waste incinerations plants according to EC directive 2000-76-EC and other plants requiring official permission. The tested measurement ranges were selected in order to secure an application range for the AMS as wide as possible. The suitability of the AMS for this application was assessed on the basis of a laboratory test and a three month field test at a municipal waste incinerator. The AMS is authorised for the ambient temperature range from +5 C to +40 C. Any potential user should ensure in consultation with the manufacturer that this AMS is suitable for the installation on which it will be installed. Basis of the certification This certification is based on: test report 936/21206693/B of 28 March 2011 of TÜV Rheinland Energie und Umwelt GmbH suitability announced by the German Environmental Agency (UBA) as relevant body the ongoing surveillance of the product and the manufacturing process publication in the German Federal Gazette (BAnz. 29 July 2011, No 113, p. 2725, chapter I, No 4.2: Announcement by UBA from 15 July 2011) AMS name: PG 250 SRM for CO, NO x and O 2 Manufacturer: Horiba Europe GmbH, Leichlingen Suitability: For measurements at plants requiring official permission (i. e. 2000-76-EC, waste incineration directive and 2001-80-EC, large combustion plants directive). Measuring ranges during the suitability test: Component Certification ranges Supplementary measurement ranges Unit CO 0 75 0 625 mg/m³ NO X as NO 0 134 0 670 mg/m³ NO X as NO 2 0 205 0 1025 mg/m³ O 2 0 25 - Vol.-% Software version: P 1000500001 C Restrictions: None qal1.de info@qal1.de page 2 of 8

Remarks: 1. An eight days period has been specified as maintenance interval. 2. The AMS as well contains measuring channels for CO 2 and SO 2. This system version is not suitability tested for the CO 2 and SO 2 channels. 3. Supplementary test (transfer to the EN 15267, supplementary ranges) to the announcement of the Umweltbundesamt of 12 August 2008 (BAnz. p. 3243, chapter I number 2.4). 4. For the component CO the requirement of the measurement uncertainty according to EN 15267-3 is not fulfilled. Test report: TÜV Rheinland Energie und Umwelt GmbH, Köln Report-No.: 936/21206693/B of 28 March 2011 Certified product This certificate applies to automatic measurement systems confirming to the following description: The measuring system HORIBA PG 250 SRM, tested during the suitability testing, consists of the following main components described as follows: Sampling Probe: M&C type PSP 4000-H, measurement gas filter heated type SP-2K ceramic material fineness 2µm Heated line: M&C type PSP 4M4 / 6 (length during suitability testing approx. 5 m) (120 C) Analyzer Horiba: PG 250 SRM (inclusive Teflon filter type DIF-K-20T and bypassed internal cooler for measuring gas) Gas dryer Horiba permeation dryer type PD-100 with 100 permeation pipes: AGC type: Air Drier SWG-100-06/66 (100 pieces) Software Evaluation-software P 1000500001 C The following additional options are applicable: Permeation pipes of Perma-Pure Inc. PD-100T-24 instead of previously mentioned permeation pipes A M&C condensation dryer type PSS 5 instead of the permeation dryer (the permeation dryer is recommended with NO 2 concentrations > 10 % of total nitrogen oxides) Instead of Teflon filter type DIF-K-20T a combination of Tipp Filter and Mist Catcher MC-050A can be implemented. qal1.de info@qal1.de page 3 of 8

General notes This certificate is based upon the equipment tested. The manufacturer is responsible for ensuring that on-going production complies with the requirements of the EN 15267. The manufacturer is required to maintain an approved quality management system controlling the manufacture of the certified product. Both the product and the quality management systems shall be subject to regular surveillance. If a product of the current production does not conform to the certified product, TÜV Rheinland Energie und Umwelt GmbH must be notified at the given address on page 1. The certification mark with the product specific ID-Number that can be applied to the product or used in publicity material for the certified product is presented on page 1 of this certificate. This document as well as the certification mark remains the property of TÜV Rheinland Energie und Umwelt GmbH. With revocation of the publication the certificate loses its validity. After the expiration of the validity of the certificate and on requests of the TÜV Rheinland Energie und Umwelt GmbH this document shall be returned and the certificate mark must not be employed anymore. The current version of this certificate and its validity is also listed at the Internet Address: qal1.de. qal1.de info@qal1.de page 4 of 8

Certification of PG 250 SRM for CO, NO x und O 2 is based on the documents listed below and the regular, continuous monitoring of the Quality Management System of the manufacturer: Basic test Test report: 936/21206693/A from 06 March 2008 TÜV Rheinland Immissionsschutz und Energiesysteme GmbH, Köln Publication: BAnz. 03 September 2008, No 133, p. 3243, chapter I No 2.4: UBA announcement from 12 August 2008 Notification Publication: BAnz. 11 March 2009, No 38, p. 899, chapter IV notification 4: UBA announcement from 19 February 2009 (Condensation dryer) Publication: BAnz. 25 August 2009, No 125, p. 2929, chapter III notification 5: UBA announcement from 03. August 2009 (other permeation dryer) Publication: BAnz. 12 February 2010, No 24, p. 552, chapter IV notification 1: UBA announcement from 25. January 2010 (Filter changing) Publication: BAnz. 26 January 2011, No 14, p. 294, chapter IV notification 16: UBA announcement from 10 January 2011 (Dryer) Initial certification according to EN 15267 Certificate No 0000001015 of: 19 August 2011 Validity of the certificate: 28 July 2016 Test report: 936/21206693/B of 28 March 2011 TÜV Rheinland Energie und Umwelt GmbH, Köln Publication: BAnz. 29 July 2011, No 113, p. 2725, chapter I No 4.2: UBA announcement from 15 July 2011. qal1.de info@qal1.de page 5 of 8

Calculation of overall uncertainty according to EN 14181 and EN 15267-3 Measuring system Manufacturer Name of measuring system Serial number of the candidates Measuring principle Test report Test laboratory Date of report Horiba Europe GmbH PG 250 SRM H0002Z8D / G0800X2D / NOC497VF / NJC3FLW9 NDIR 936/21206693/B TÜV Rheinland Energie und Umwelt GmbH 2011-03-28 Measured component CO Certification range 0-75 mg/m³ Evaluation of the cross sensitivity (CS) (system with largest CS) Sum of positive CS at zero point 1.12 mg/m³ Sum of negative CS at zero point 0.00 mg/m³ Sum of postive CS at reference point 0.50 mg/m³ Sum of negative CS at reference point -0.30 mg/m³ Maximum sum of cross sensitivities 1.12 mg/m³ Uncertainty of cross sensitivity 0.645 mg/m³ Calculation of the combined standard uncertainty Tested parameter u u² Standard deviation from paired measurements under field conditions * u D 1.089 mg/m³ 1.186 (mg/m³)² Lack of fit u lof 0.290 mg/m³ 0.084 (mg/m³)² Zero drift from field test u d,z -1.212 mg/m³ 1.469 (mg/m³)² Span drift from field test u d,s -1.299 mg/m³ 1.687 (mg/m³)² Influence of ambient temperature at span u t 0.586 mg/m³ 0.343 (mg/m³)² Influence of supply voltage u v 0.188 mg/m³ 0.035 (mg/m³)² Cross sensitivity (interference) u i 0.645 mg/m³ 0.416 (mg/m³)² Influence of sample gas flow u p -0.027 mg/m³ 0.001 (mg/m³)² Uncertainty of reference material at 70% of certification range u rm 0.606 mg/m³ 0.368 (mg/m³)² * The larger value is used : "Repeatability standard deviation at span" or "Standard deviation from paired measurements under field conditions" ( ) Combined standard uncertainty (u C ) u c = u max, j 2.36 mg/m³ Total expanded uncertainty U = u c * k = u c * 1.96 4.63 mg/m³ 2 Relative total expanded uncertainty U in % of the ELV 50 mg/m³ 9.3 Requirement of 2000/76/EC and 2001/80/EC U in % of the ELV 50 mg/m³ 10.0 Requirement of EN 15267-3 U in % of the ELV 50 mg/m³ 7.5 qal1.de info@qal1.de page 6 of 8

Calculation of overall uncertainty according to EN 14181 and EN 15267-3 Measuring system Manufacturer Name of measuring system Serial number of the candidates Measuring principle Test report Test laboratory Date of report Horiba Europe GmbH PG 250 SRM H0002Z8D / G0800X2D / NOC497VF / NJC3FLW9 CLD 936/21206693/B TÜV Rheinland Energie und Umwelt GmbH 2011-03-28 Measured component NO Certification range 0-134 mg/m³ Evaluation of the cross sensitivity (CS) (system with largest CS) Sum of positive CS at zero point 0.00 mg/m³ Sum of negative CS at zero point 0.00 mg/m³ Sum of postive CS at reference point 1.70 mg/m³ Sum of negative CS at reference point -2.60 mg/m³ Maximum sum of cross sensitivities -2.60 mg/m³ Uncertainty of cross sensitivity -1.501 mg/m³ Calculation of the combined standard uncertainty Tested parameter u u² Standard deviation from paired measurements under field conditions * u D 1.005 mg/m³ 1.010 (mg/m³)² Lack of fit u lof -0.580 mg/m³ 0.336 (mg/m³)² Zero drift from field test u d,z 0.619 mg/m³ 0.383 (mg/m³)² Span drift from field test u d,s 2.321 mg/m³ 5.387 (mg/m³)² Influence of ambient temperature at span u t 3.153 mg/m³ 9.941 (mg/m³)² Influence of supply voltage u v 0.125 mg/m³ 0.016 (mg/m³)² Cross sensitivity (interference) u i -1.501 mg/m³ 2.253 (mg/m³)² Influence of sample gas flow u p -0.081 mg/m³ 0.007 (mg/m³)² Uncertainty of reference material at 70% of certification range u rm 1.083 mg/m³ 1.173 (mg/m³)² Converter efficiency for AMS measuring NOx u ce 3.484 mg/m³ 12.138 (mg/m³)² * The larger value is used : "Repeatability standard deviation at span" or "Standard deviation from paired measurements under field conditions" ( ) Combined standard uncertainty (u C ) u c = u max, j 5.71 mg/m³ Total expanded uncertainty U = u c * k = u c * 1.96 11.20 mg/m³ 2 Relative total expanded uncertainty U in % of the ELV 131 mg/m³ 8.5 Requirement of 2000/76/EC and 2001/80/EC U in % of the ELV 131 mg/m³ 20.0 Requirement of EN 15267-3 U in % of the ELV 131 mg/m³ 15.0 qal1.de info@qal1.de page 7 of 8

Calculation of overall uncertainty according to EN 14181 and EN 15267-3 Measuring system Manufacturer Name of measuring system Serial number of the candidates Measuring principle Test report Test laboratory Date of report Horiba Europe GmbH PG 250 SRM H0002Z8D / G0800X2D / NOC497VF / NJC3FLW9 Paramagnetism 936/21206693/B TÜV Rheinland Energie und Umwelt GmbH 2011-03-28 Measured component O 2 Certification range 0-25 Vol.-% Evaluation of the cross sensitivity (CS) (system with largest CS) Sum of positive CS at zero point 0.00 Vol.-% Sum of negative CS at zero point 0.00 Vol.-% Sum of postive CS at reference point 0.32 Vol.-% Sum of negative CS at reference point 0.00 Vol.-% Maximum sum of cross sensitivities 0.32 Vol.-% Uncertainty of cross sensitivity 0.185 Vol.-% Calculation of the combined standard uncertainty Tested parameter u u² Standard deviation from paired measurements under field conditions * u D 0.053 Vol.-% 0.003 (Vol.-%)² Lack of fit u lof -0.035 Vol.-% 0.001 (Vol.-%)² Zero drift from field test u d,z -0.029 Vol.-% 0.001 (Vol.-%)² Span drift from field test u d,s 0.029 Vol.-% 0.001 (Vol.-%)² Influence of ambient temperature at span u t 0.072 Vol.-% 0.005 (Vol.-%)² Influence of supply voltage u v 0.027 Vol.-% 0.001 (Vol.-%)² Cross sensitivity (interference) u i 0.185 Vol.-% 0.034 (Vol.-%)² Influence of sample gas flow u p -0.006 Vol.-% 0.000 (Vol.-%)² Uncertainty of reference material at 70% of certification range u rm 0.202 Vol.-% 0.041 (Vol.-%)² * The larger value is used : "Repeatability standard deviation at span" or "Standard deviation from paired measurements under field conditions" ( ) Combined standard uncertainty (u C ) u c = u max, j 0.29 Vol.-% Total expanded uncertainty U = u c * k = u c * 1.96 0.58 Vol.-% 2 Relative total expanded uncertainty U in % of the range 25 Vol.-% 2.3 Requirement of 2000/76/EC and 2001/80/EC U in % of the range 25 Vol.-% 10.0 Requirement of EN 15267-3 U in % of the range 25 Vol.-% 7.5 ** For this component no requirements in the EC-directives 2001/80/EG und 2000/76/EG are given. The chosen value is recommended by the certification body. qal1.de info@qal1.de page 8 of 8