Integrated Security Technology primion security solutions
Contents Modern security management 3 Comprehensive security to meet individual demands 4 High flexibility through customising 6 The features of psm2200 8 The benefits of psm2200 11 Hardware to control your security system 12 Ordering Information 15
Modern security management We focus our attention on the special requirements of your company Every individual s need is important Modern security management is a task that is equal both in complexity and responsibility, which leaves nothing to chance. A perfect interaction of different functions and competencies. From a technical standpoint, modern security management unifies the widest imaginable range of sub-systems into one powerful, multifunctional system. Establishing such a total system can be done modularly, in single steps, or holistically as one single, comprehensive project. What is critical, is to work, right from the start, with open and therefore expandable security systems, which offer controls that are as easy to use as they are comprehensive. For this reason, primion offers single-source, holistic security solutions, consisting of» Hazard detection systems» Security command centre solutions» Access control systems» Time and attendance systems» Video technology 3
Comprehensive security to meet individual demands psm2200 - The central solution for your hazard management Have you got your security under control? Different hardware, different manufacturers but still a system: psm2200 gives you the choice to select from any system suppliers and nonetheless gives you uniform operation of all hazard management systems. psm2200 gives you an overview over all your systems. Any not just that. With psm220, you can initiate a limitless number of different types of measures for all connected systems, individually, automatically and exactly as you need them for every single case. The security in your company and the corresponding buildings is significantly increased through the centralised control and complete overview. Simple: Operate and identify alarm signals You don't need any special previous knowledge of the connected devices to be able to operate the system. You just operate them through psm2200. Comprehensive and flexible customising options enable an optimum adaptation to your requirements and your experience. You can identify each alarm message from each system, with its exact location through your floor plans, together with all the individual, detailed information your require. Tailored to your needs, you initiate corresponding measures automatically, whether this is making a call to the nearest police station or closing a door. All measures are possible. The system doesn't just produce individual messages. Further logs about how the messages are processed are also created. 4
Keeping things under control You control interactive event sequences in line with your requirements. With your own Groovy scripts and individually configurable Workflows, you trigger all imaginable processes, decisionbased and automated. You configure texts, graphics with text, tables and/or mixed views on a need-to-have basis, which give you the control you need later. Using psm2200, you integrate and control functions such as primion access control, intrusion and fire detection systems, digital, analogue and IP video systems, emergency evacuation route equipment, further customer-specific interfaces and at a glance, you can see the current state of all connected systems. All incoming messages, all actions executed by the system and all user interactions are saved and logged. The correct operation of your system is ensured through the assignment of different user rights. When used as a Client/Server system you can send alarms or messages to a large number of computers/clients. When used as a Gateway, e.g. BACnet or OPC, rules can be employed to convert, filter and prepare data for third-party systems. 5
High flexibility through customising Individuality and flexibility An unlimited number of users and an individual GUI design make it possible to create completely personalised views. Create your own individual authorisations structure; assign multiple-roles to each user from 64 different roles for control functions. psm2200 can work with all systems and if that is not yet the case with your system, ask us. Essentially however, psm2200 Security Command Centre is hardware-independent and open to all commonly used systems. With 20 different drivers per server and the administration of multiple devices per driver, the Security Command Centre from primion is a very high-quality and powerful system. Plug & play makes configuration easier when changes have to be made in the data structure. psm2200 automatically handles changes in a running system on-the fly, so to speak. System configuration Centralised overview You can monitor what is going on in your company on up to 9 monitors (max. 4 physical and 5 virtual) with up to 16 windows on each of those monitors. Take your pick: psm2200 can show you everything at a glance, as graphics, tables, Web or video views. Hardware configuration Security through informative transparency If there is an emergency, you can display special features such as emergency exit routes and all fire and access detectors, for example. You will miss nothing, because of the countless options for displaying graphics, websites, plugins, scripts (e.g. Groovy) and icons. Of course, psm2200 supports a wide range of formats such as.bmp,.jpg,.tif,.svg and.wmf as well as.pdf and.dwf. Basic layout definition 6
Up to date at a glance With one or more building floor plans in the system, it is very easy to be completely up to date at all times about what is going on throughout your company s premises, in individual parts of buildings or on specific floors. You are informed continuously about any problems, each alarm, all open doors and much more. At the same time, you can see at a glance the corresponding history about previous incidents. With a theoretically unlimited number of datapoints displaying such information to you on your floor plans, you can monitor several hundred datapoints at the same time, depending on the computer performance, each producing a range of messages. Icons for interactive control With 6 different functions per icon, efficient communication and control is ensured whether you are controlling command calls, displaying popups as a user interface, calling programs, displaying menus or swapping graphics. Floor plan editing psm2200 live psm2200 shows you the most important details of your security system in a clear form and initiates the required actions. The different alarms are displayed as icons. As soon as an alarm is received, the appearance of the icon changes automatically. You have the option of responding interactively. Alarm processing is logged so that at all times you can trace who dealt with which alarm and how quickly. Freedom through Groovy The option of integrating Groovy scripts gives you a previously unknown freedom to design required actions and checks and balances, through simple scripts. You can define alarm processing and actions such as displaying error messages while at the same time closing doors in various parts of the building, to name but a few options. Live operation 7
The features of psm2200» Open security management system, focussed on security applications and requirements, with the visualisation and processing of messages» Modular construction with open system architecture» Graphical and text-based representation of all connected system states» Independent driver concept (-> third-party)» Client-data enabled» Powerful script engine» Configuration options for user interface and workflows» Fast, individually configurable program interfaces with overviews, multiple graphics, active icons and quick workflow rules» Uniform operation of different hardware from different manufacturers» State-of-the-art user interface» Multi-monitor operation» Numerous graphic formats» Scalable all the way from embedded touch screens right up to a client-enabled, redundant Client / Server solution» Server-based activation of devices» Redundancy options» SQL database basis» Operating system independence through the use of Java technology» Workstation and / or WebViewer client» Support for Web solutions» Multi processing, multi-threaded architecture» Support for multi-processor systems» In-memory database structure for the rapid processing of large amounts of information psm2200 Access control Building management / Fault reporting Video systems Fire detection Time & attendance Intrusion detection Emergency evacuation route control Further interfaces to:» Hospital solutions» Telephony systems» Audible alarm notifi cation systems» BACnet / - OPC client 8
9
10
The benefits of psm2200» Independence from system suppliers» State-of-the-art, Java-based system architecture» Reduced integration costs» Automatic configuration changes in a running system» Powerful script languages (HTML, Java, Groovy and internal commands)» Universal table model with individual configuration options (column selection and layout, filters, templates)» Up to 4 physical monitors and 5 virtual monitors per client (or 1 physical + 8 virtual monitors is also possible)» Scalable all the way from the operator unit right up to a complex, major system» Identical user interface for Web client and desktop client» In-memory database enables the display of many datapoints at the same time and reduces processing time» Access to primeweb data, e.g. routes, reader groupings» Integrated application of third-party data structures and graphics» Unification of different sub-systems into one primary system» Simplification of the operation and monitoring and multiple / individual components» Operation without any specialist knowledge of the application» Centralised operation, monitoring of control of all connected components» Display of individually definable alarms and messages, depending on user requirements» Supports the operators with configurable Workflows» Bundling of all necessary information for easy processing» Optimised data gathering» Reliable data forwarding 11
Hardware to control your security system IDT 32 Controller for access control, intrusion detection and alarm systems The core of the hardware is the intelligent IDT 32 controller. This device has successfully passed the test for recognition in accordance with VdS Class C certification. Up to 7,500 datapoints per IDT 32 can be achieved, thanks to the modular component structure and the support of different Bus systems. This figure reflects the excellent performance of the highly integrated 32 Bit microcontroller system. As well as comprehensive access control functions such as airlock control and freely programmable event controls, the IDT 32 also fulfils all the functionality of an alarm system. Up to 1,024 detectors, such as motion, smoke and glass breakage detectors can be connected. Arming/ disarming is either done manually through operating panels or automatically dependent on different events and states. The integration of access control and alarm technology into one system creates many benefits for the user, such as automatic arming when no one is in the building or the avoidance of false alarms through automatic refusal of access bookings when an area is armed. The IDT 32 is a full-function, fullyfeatured security system. ODU 100 Credential reader for security and intrusion detection systems The ODU 100 Operator and display unit has been developed for applications in the area of integrated security technology. It includes operating functions for an intrusion detection system (IDS). Display panel for your security system The display panel gives an overview of up to 128 alarm and status states. If the panel is deployed in combination with an intrusion detection system, it can inform an employee whether the system is to be armed as they leave the building. Motion detectors for your intrusion detection and alarm system Motion detectors are used to monitor rooms. Through their mirror optics, they detect infrared heat radiation in a wavelength that is emitted by the human body. The motion detectors are available either with bus connections or with conventional connections. 12
psm 2200, Security Command Centre Ethernet TCP/IP CPU MB1M M8O8 RS 485 IDT 32 Compliant with VdS Class C requirements for hazard detection systems Display panel max. 1 km 4-core cable 1 with up to 63 detectors Max. 8 detector groups, each with a maximum 20 detectors / contacts Detector bus 4-core cable 2 with up to a further 63 detectors Roller shutter magnetic contact ODU 100 Infrared motion detector Gas detector prime crystal reader External signalling device Glass breakage sensor prime prox potted with keypad and weather-proof housing Optical smoke detector Water detector Bolt switch contact Mini-module for the connection ofthird party detectors Hold-up detector max. 1 km 13
Transmission devices for your intrusion detection and alarm system The newest transmission devices belong to the next generation of IP transmission equipment. The devices are suitable for deployment in intrusion and fire detection systems. Various connection options are available as transmission routes for the individual devices. In some cases, it is possible to combine them:» Analogue telephone cables» IP transmission, ISDN connections» Ethernet connection» GSM radio frequency External signalling devices for your security in the case of intruders, attacks, fire alarms or technical alarms Various VdS-approved signalling devices are available for serious cases. You can select from acoustic and optical signalling devices those that match your application requirements. There are also signalling devices available that combine acoustic and optical functions. Further security components You can get all the hazard detection system components that are necessary for the operation of a security system from primion Technology AG. This includes the following components with multiple VdS approvals:» Hold-up detectors» Sounders» Gas detectors» Water detectors» Smoke detectors» Blocking elements» One, two or five detector group modules» Detector bus mini-modules» Detector sockets» Flush / surface mounted magnetic contacts» Roller shutter magnetic contacts» Bolt switch contacts» Passive glass breakage sensors» Cable links Power charging units For your security during power outages Our power charging units in tamper-monitored steel housings ensure the equipment emergency power supply in the case of power failures, in accordance with the guidelines of the VdS. 14
Ordering Information psm2200 Security Command Centre S301-000.01 psm2200 Lite - non-expandable - 3 Users, 2 Interfaces, 3,000 datapoints S302-000.01 S302-001.01 S302-001.02 S302-002.01 S302-002.02 S302-002.03 S302-003.01 S302-004.01 S302-004.02 S302-005.01 S302-005.02 S302-006.01 S302-006.02 S302-006.03 S302-006.04 S302-006.05 S302-006.06 S302-006.07 S302-006.08 psm2200 Basic 1 User, 1 System administrator, 1,000 datapoints psm2200, 1-4000 datapoints Expansion by 500 datapoints psm2200, > 4000 datapoints Expansion by 500 datapoints psm2200, 1-4 clients Expansion by one client licence psm2200, 5-99 clients Expansion by one client licence psm2200, > 99 clients Expansion by one client licence psm2200 with redundancy Licence for redundant server psm2200 Multi-Graphic Licence for 3 monitor displays per client psm2200 Multi-Graphic Licence for 4 monitor displays per client psm2200 Multi-User - User User expansion, per user psm2200 Multi-User - Administrator Administration expansion, as additional user psm2200 HDS interface Interface connection licence, per HDS psm2200 primion access control interface primion access control system interface licence psm2200 primion time and attendance interface primion time and attendance system interface licence psm2200 Evacuation route management interface Door connection licence, per door psm2200 Visual surveillance system interface Video management interface licence, per video server psm2200 Individual interface OPC interface licence (server) psm2200 Individual interface OPC interface licence (client) psm2200 Individual interface BACnet interface licence 15
primion Technology AG Steinbeisstr. 2-5 72510 Stetten am kalten Markt, Germany Phone: +49 75 73 / 9 52-0 Fax: +49 75 73 / 9 20 34 info@primion.de www.primion.de P061-050.00