BP WIND ENERGY POLICIES AND PROCEDURES



Similar documents
Flammable and Combustible Liquids. Slide 1 (of 23)

OSHA Office of Training and Education 1

Notes. Material 1. Appropriate Flammable Liquids

Sample Written Program. For. Flammable Liquids

ADMINISTRATIVE SERVICES MANUAL

FLAMMABLE AND COMBUSTIBLE LIQUIDS. n OSHA Changes

Flammable Liquids 29 CFR

Queen's University Environmental Health and Safety

Waste Oil Collection / Storage

HealthandSafetyOntario.ca. Introduction. Storage Containers. Storing Flammable Liquids

Static Spark Ignites Flammable Liquid during Portable Tank Filling Operation

Static Electricity. A Health and Safety Guideline for Your Workplace. What Are Some Sources of Static Electricity? What is Static Electricity?

Model Safety Program

Flammable Liquids Storage

Flammable Liquids Storage

Container Management for Hazardous Waste Generators Technical Guidance Document HW-2005-G1

MOTOR FUEL DISPENSING SAFETY

Section III Hazardous Materials Management

STORAGE AND HANDLING OF FLAMMABLE AND COMBUSTIBLE LIQUIDS

Compressed Gases The Dangers

LCT 1025 (08/08) Copyright 2008 Harleysville Mutual Insurance Company Page 1 of 5 All rights reserved

Ethanol Vehicle and Infrastructure Codes and Standards Citations

Standard Operating Procedure: Flammable Liquids

How To Safely Handle A Spill

Wilkins Safety Group

APPENDIX G Materials Storage and Handling Guidelines

Good Housekeeping Practices for DPW/Fleet Maintenance Facilities

Flammable liquid classes: Combustible Liquid Classes. Class IC. Class II. Class IB F.P. below 22.8 C (73 F), boiling point at or above 37.

527 CMR: BOARD OF FIRE PREVENTION REGULATIONS 527 CMR 14.00: FLAMMABLE AND COMBUSTIBLE LIQUIDS, FLAMMABLE SOLIDS OR FLAMMABLE GASES

Hazardous Waste Determination and Management Plan

OREGON FIRE CODE Interpretations and Technical Advisories

TYPICAL FIRE SAFETY INSPECTION VIOLATIONS

Presented by: Rich Perry Marsh Risk Consulting

ACTIVITY NAME. Training Requirements for Spill Prevention Control and Countermeasures (SPCC) 40 CFR Part 112 Naval Air Station Corpus Christi Texas

Civil Engineering Sector Labour-Management Health and Safety Committee

SELF-INSPECTION PROGRAM FOR FIRE PROTECTION EQUIPMENT

Regulated Waste Storage

FLAMMABLE AND COMBUSTIBLE LIQUIDS

All You Ever Wanted to Know About Fire Extinguishers...

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

The following definitions apply with regard to requirements specified in this document:

Standard Operating Procedure

FLAMMABLE LIQUIDS COMPLIANCE NOTE

In accordance with NFPA 30, these containers are not to store Class I flammable liquids.

Flammable Storage in a Biotech Facility

ABC CIRCUITS 10 Circuit Drive Circuit Town, IN SLUG CONTROL PLAN

Compressed Gas Cylinder Storage and Handling Guide

Mechanical Systems Competency 1.20

FACILITY ENVIRONMENTAL COMPLIANCE

The following definitions apply with regard to requirements specified in this document:

STORE HAZARDOUS SUBSTANCES SAFELY. incompatibles gas cylinders

OSHA Tank Venting DEFINITIONS

CITY OF WASHINGTON SPILL PREVENTION, CONTROL AND COUNTERMEASURE PLAN

APPENDIX O. Spill Prevention and Emergency Response Plan. G3 Terminal Vancouver Port Metro Vancouver Project Permit Application APPENDIX O

MAINE DEPARTMENT OF ENVIRONMENTAL PROTECTION

SMDC/ARSTRAT ENVIRONMENTAL COMPLIANCE TRAINING

HAZARDOUS WASTE SATELLITE ACCUMULATION MANAGER RESPONSIBILITIES

Code Compliance Guideline: Swimming Pool Chemicals

FDNY C14 Certificate of Fitness Quiz

Dip Tanks. RS 1030 (9/13) 2013 Nationwide Mutual Insurance Company Page 1 of 9 All Rights Reserved


ALLEGANY WIND POWER PROJECT CONSTRUCTION SPILL PREVENTION PLAN

ALVERNIA UNIVERSITY OSHA REGULATION: 29 CFR WELDING, CUTTING, AND BRAZING ( HOT WORK ) SECTION: 3600

IAC 7/2/08 Agriculture and Land Stewardship[21] Ch 44, p.1

Standards for Material Handling, Storage, and Disposal

Safety Manual Title: Spill Prevention & Response Review Date: 6/1/2014

Technical Requirements for Aboveground Storage Tanks (ASTs) Storing Class IIIB Liquids (other than used oil)

Budget Basins Modular Spill Platform Spill Containment Pallets Spill Containment Platforms

FUELING AND FUEL STORAGE

Morrison Bros. Co. General Product Specifications

HOT WORK PERMIT PROCEDURES

Pollution Prevention And Best Management Practices For Dry Cleaners Operating In Broward County

DIRECTIVE 055: STORAGE REQUIREMENTS FOR THE UPSTREAM PETROLEUM INDUSTRY

Lids, Leaks, Labels and Location All About Satellite Accumulation Martin E. Sánchez Principal Environmental Specialist

Spill Control Prevention Plan (SCPP)

Propane Fuel. Material Safety Data Sheet

SPILL PREVENTION, CONTROL AND COUNTERMEASURE PLAN

Site and Storage Conditions for Class 3.1 Flammable Liquids

COMPRESSED GASES. 1.2 The contents of each cylinder and container must be clearly identified (by tag or stamp) on the cylinder.

The potential to adversely affect human

Enviro Safety Products Resource Center. OSHA Checklist for General Industry

Here are some hazardous wastes commonly generated by the marina industry:

OPERATIONS & MAINTENANCE (O&M) FOR PROPANE STORAGE FACILITIES

SPILL PREVENTION AND RESPONSE PLAN TEMPLATE FOR BUSINESSES IN DAYTON S SOURCE WATER PROTECTION AREA

GUIDELINE FOR SAFETY IN THE HANDLING OF FLAMMABLE LIQUIDS

exit routes and fire protection

Dry Chemical Systems TWIN AGENT CAPABILITY

Appendix VIII: Spill Prevention, Control and Countermeasure (SPCC) Plans

New York State Department of Environmental Conservation 625 Broadway, Albany, NY Environmental Self Audit For Small Businesses

UDOT SPILL PREVENTION and RESPONSE PLAN for CONSTRUCTION SITES

Storing, Using and Handling Compressed Gases

Spill Prevention, Control and Countermeasure (SPCC) Training

Used Oil Guidance. Tank and Secondary Containment Requirements For Used Oil Processors

CITY AND COUNTY OF DENVER POLICY DENVER FIRE DEPARTMENT

Portable petrol storage containers

A GROUNDWATER PROTECTION PLAN FOR HOME HEATING OIL TANKS

SUBJECT: Effective Date: Procedure Number: Contractor Environmental Management. 09/03/13 emp11 Procedures

Transcription:

BP WIND ENERGY POLICIES AND PROCEDURES Document Control Details

1.0 Purpose/Scope 1.1 This procedure provides the minimum requirements to be followed for the storage of flammable or combustible materials in the workplace. 1.2 It applies to all employees and on-site contractors engaged in operations covered by BPWE HSSE procedures. 2.0 Reference 2.1 BPWE HazCom Procedure, HSSE 50.10.01 2.2 OSHA 29 CFR 1910.106, Flammable and Combustible Liquids 2.3 OSHA 29 CFR 1926.152, Flammable and Combustible Liquids 2.4 National Fire Protection Association NFPA 30 - Flammable and Combustible Liquids Code 2.5 National Fire Protection Association; NFPA 58 LP Gas Code 3.0 Responsibilities 3.1 All Users Before storing and/or handling flammable or combustible liquids: A. Be familiar with and adhere to all requirements contained in this procedure, B. Review Material Safety Data Sheet (MSDS) to identify all hazards. 3.2 Facility/Project Managers A. Verify all requirements of this procedure are implemented and enforced. B. Ensure that flammable or combustible liquids are stored in a safe manner and in accordance with this procedure. C. Confirm that all personnel are properly trained before being allowed to load or unload flammable or combustible products, and verify that all training has been documented. 4.0 Acronyms and Definitions Acronym DOT MSDS NFPA OSHA psia Acronyms Table Definition US Department of Transportation Material Safety Data Sheet National Fire Protection Association Occupational Safety and Health Administration Pounds per square inch absolute

Term Boiling Point Bonding Closed Container Combustible Liquids Definition Definitions Table The temperature at which a liquid boils, given in either F or C, at a pressure of 14.7 pounds per square inch absolute (psia). The process of establishing electrical continuity between two or more conductive surfaces. A container sealed by means of a lid or other device that will not allow liquid or vapor passage at ordinary temperatures. Liquids that have a flashpoint at or above 100 F (37.8 C). Combustible liquids are subdivided as follows: Class II liquids have flashpoints at or above 100 F (37.8 C) and below 140 F (60 C). Class IIIA liquids have flashpoints at or above 140 F (60 C) and below 200 F (93.3 C). Class IIIB liquids have flashpoints at or above 200 F (93.3 C). Container Flammable Liquids Any can, barrel or drum that conforms to OSHA and/or DOT requirements. Liquids that have a flashpoint below 100 F (37.8 C) and have a vapor pressure not exceeding 40 psia at 100 F(37.8 C). Flammable liquids are known as Class I liquids and are subdivided as follows: Class IA liquids have a flashpoint below 73 F (22.8 C) and a boiling point below 100 F (37.8 C). Class IB liquids have a flashpoint below 73 F (22.8 C) and a boiling point at or above 100 F (37.8 C). Class IC liquids having a flashpoint at or above 73 F (22.8 C) and below 100 F (37.8 C). Flashpoint Grounded Portable Tank Safety Can NOTE: The Department of Transportation (DOT) definition of flammable liquid is slightly different. Refer to DOT shipping regulations for clarification. Department of Transportation; 49 CFR 174.67, 49 CFR 177.837 The lowest temperature at which a liquid will give off vapors in a sufficient concentration to form an ignitable mixture with air near the surface of the liquid. Electrically connected to the earth or some other conducting body that serves in place of the earth. A closed container with a liquid capacity of more than 60 U.S. gallons and not intended for fixed installations. A container of not more than five gallons capacity, having a spring loaded lid and spout cover, and so designed that it will safely relieve internal pressure when subjected to fire exposure.

5.0 Procedure 5.1 Bonding and Grounding Dispensers A. Flammable and combustible liquids can present a static electricity hazard, depending on their ability to generate static electricity, how well they conduct electricity (conductivity), and their flash point. Solvents and fuels produced from petroleum, e.g., benzene, toluene, mineral spirits, gasoline, can build up a charge when they are poured or flow through hoses. B. To prevent static electricity build-up and to prevent sparks from causing a fire, it is important to bond and ground metal dispensing and receiving containers together before pouring. 1. One way to bond containers is to securely attach a special metal bonding strap or wire to both containers. 2. Some liquid transfer pumps have self-bonding hoses. 3. Keeping contact between the metal container and a conducting nozzle can prevent sparking but this method is unreliable because it can be hard to make and maintain good electrical contact for the entire transfer. C. In addition to bonding, the dispensing container must be grounded so that the static charge can drain off to ground. 1. Grounding methods include connection to a buried metal plate, a metallic underground water pipe (never gas), and metal building framework. 2. Specially designed and approved bonding and grounding wire assemblies are available from safety equipment retailers. D. For medium-sized containers (5 60 US gallons), it is advisable to ground the metal container and fill the container from the bottom through a long, grounded metal pipe or grounded conductive hose. E. When filling non-conducting portable containers, the NFPA recommends that a grounded dip pipe or grounded wire be in the liquid in the container while it is being filled. The filling rate should be minimized, especially if there is a filter in the line. F. Plastic containers will not be used to collect, store or transfer flammable liquids, unless liquids are incompatible with a metal container and an acceptable alternative is secured. 5.2 Flammable Materials Storage Cabinet A. Flammable liquids will be stored in a UL listed/fm approved metal flammable materials cabinet that: 1. Has a label that states FLAMMABLE KEEP FIRE AWAY, 2. Is in an area with no more than three flammable storage cabinets, 3. Contains not more than 60 gallons of flammable or 120 gallons of combustible liquid in a single cabinet.

5.3 Dispensing and Handling Bulk Flammable Liquids A. Drip Cans A drip-can should be positioned below each drum faucet to catch spills or any leaking from the faucet. A faucet that routinely leaks should be repaired or replaced as soon as practical. One-gallon size drip cans are adequate to provide a safe capacity margin between routine emptying. Disposal of the collected drippings must be in accordance with local, state, and federal law. B. Drum Faucets Safety faucets, of non-sparking material, for drawing off flammable liquids from drums should be self-closing and equipped with drip-proof seals. Faucets should be FM-approved and have provisions to be padlocked to prevent unauthorized withdrawal of drum contents. C. Drum Venting Drums of flammable liquids require an FM approved drum venting device to relieve pressure build-up due to heat and to prevent creation of a vacuum when liquid is being drained off or the drum is subject to sudden cooling. Either pressure or vacuum can cause container failure. If the drum is equipped with an FM-approved transfer pump, no auxiliary venting devices are required because automatic pressure and vacuum relief are incorporated in the pump s design. D. Drum Pumps Pumping of flammable liquids from drums into safety containers is faster and provides fewer opportunities for spills and procedural errors. When pumps are used, no drip cans or separate vents in the drum are required. Always use FM-approved pumps. The pump is installed directly in the two-inch drum bung opening. The drum remains in the vertical position, which reduces handling time and eliminates the need for a drum cradle. Pumps are available with either a fill hose or spout and drip tray. Pump hoses should have integral bonding wires (FM approved). Pumps with drip trays used to fill small containers require a separate bonding wire. 5.4 Fire Extinguisher Rating A. A fire extinguisher with a rating of at least 10A, 60BC, C is required. B. The fire extinguisher must be located no closer than 25 feet and no further than 75 feet away from any flammable liquids storage/dispensing areas outside of an approved storage cabinet.

5.5 Container Labeling A. All containers containing flammable or combustible liquids must be labeled as to their contents in accordance with the BPWE Hazard Communication Procedure. B. This includes but is not limited to fuel cans or safety cans containing gasoline, diesel, or other blended fuel. C. When stored, containers should be positioned so their labels can be viewed. 5.6 Routine Inspection A. Storage areas should be routinely inspected to ensure that drums and containers are kept closed, that their labels are readable and intact, and that all small containers are stored safely inside an approved storage cabinet. B. Metal drums should be held on secondary containment pallets and not be allowed to rest on concrete flooring. C. Dampness from the concrete can result in rusting and failure of the bottom seam. D. If a drum shows signs of weeping or bulging, the contents should be immediately transferred into a new drum or the drum placed inside a containment drum. 5.7 Environmental A. Flammable liquids, such as gasoline, should never be used for general maintenance cleaning. Improper use represents an extreme fire danger and a health risk to the user and to others in the area. The use of flammable liquids for general maintenance cleaning may also violate local air quality control district rules and regulations. B. Always be aware that some combustible liquids can be as dangerous as flammable liquids depending on local conditions such as temperature and altitude. On very hot days or at high altitude, it is more likely that a combustible liquid can emit sufficient vapor to create a hazard. C. Storage containers holding flammable or combustible liquids should not be stored in areas subject to direct sunlight. D. Dispensing drums should be equipped with conservation vents to minimize product loss due to tank breathing. Dispensing drums should be shielded from exposure to direct sunlight, strong drafts, or sudden changes in temperature. E. Storage areas should be bermed and designed to contain storage volumes to prevent spillage from leaving the area. F. Flammable liquids should be purchased according to need since unwanted or unusable liquid waste requires disposal as a hazardous waste under local regulations. Keep all waste products segregated to promote recycling. G. Periodically review the need to use and store flammable and combustible liquids. Assess whether: Vehicles can be fueled at a nearby station. Diesel equipment can be used in place of gasoline or propane equipment (Note: The choice of fuel type equipment to be used may be dictated by permit conditions.). Aqueous cleaners can be used in place of solvents.

6.0 Training H. Waste Disposal: Disposal of empty drums and/or any unused flammable or combustible liquids shall be done by a BPWE approved, licensed hazardous waste disposal contractor. 6.1 All personnel engaged in flammable and combustible liquids storage operations are to be properly trained in accordance with this HSSE procedure. 7.0 Auditing 7.1 The requirements called for in this procedure are subject to periodic inspection by the BP site manager and annually during the BPWE site specific audit. 7.2 This procedure shall be audited (and updated as necessary) every three years.

Attachment A: Guidelines for Flammable Liquid Dispensing

Document Control Details Document Name Scope BP Wind Energy Document # HSSE 28.10.01 Issue Date 9/27/2011 Revision Date Next Review 9/27/2014 Authority Pat West COO BPWE Custodian Dale Smith HSSE Manager Operations Rev# Revision Date Revision Detail Authority Custodian