MisMatched Unions have caused fatal accidents! Do you know :



Similar documents
Upstream Operations: Fatalities Related to Confined Vapors and Gases. Susan Monroe, M.S., CIH US DOL/OSHA

BOP PRESSURE TESTING PROCEDURE

Application Data Important Safety Information

Emergency Plan. This emergency plan provides a format of data essential in an emergency situation.

HAMMER UNIONS HAMMER UNIONS. Figure 100 TxT Figure 200 & 206 TxT Figure 602 TxT. Figure 1002 TxT Figure 1002 BW Figure 1502 TxT Figure 1502 BW

These features have made Lo Torc valves the choice of high pressure plug value users, worldwide:

Universal Installation and Maintenance Instructions Double Wall Spill Containment Bucket (5 and 15 gal)

Submersion/Insertion Toroidal Sensor

HAND PUMP OPERATION, SERVICE AND PARTS INSTRUCTION MANUAL

880 HYDRAULIC BENDER

Power Cube Open Source Ecology Page 1. Power Cube. Version 4

INSTRUCTION MANUAL IM042. Slide Rail Systems - Series A10 INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Repair of Hyd-ro-ac Actuators

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

1.8 CRANKSHAFT OIL SEALS

Specification for Rotary Drill Stem Elements

Aker Drilling Riser Brazil

Working Pressure - Hose Ends

GAS DISTRIBUTION PRODUCTS STEEL SERVICE TEES

Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING

How To Launch A Rocket From A Formica

Easy Tool Retracting System CMC-SR2159ER36

H41 Electrical Stage Aft Air Conditioner Unit Installation

TYPE E Main Valve Sizes 3 /8 through 12



NITROUS TRANSFER PUMP INSTRUCTIONS

Red Alert Program In Drilling Rigs:

For exploded diagram and part number information, refer to the Spare Parts Catalog available on our website at

Module No. # 02. Impact of oil and gas industry on marine environment

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

Fatality Assessment and Control Evaluation Project

Drilling for Deepwater Data: A Forensic Analysis of the Gulf of Mexico Deepwater Horizon Disaster

Installation and Commissioning Manual Solar Stations FlowCon Max Evolution II

Occupational Disease Fatalities Accepted by the Workers Compensation Board

Mueller B-101 and A-3 Drilling and Tapping Machines

Operating Instructions Drill rig DRU160

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

Bimetal thermometer Model 52, industrial series

ROUGHNECK II Pumpless Drain

Deepwater Horizon Summary of Critical Events, Human Factors Issues and Implications

Citation 1 Item 1a. #22: Struck by Inspection #

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

Hose and Tube Fittings Series 1-3

Oil and Gas Pipeline Design, Maintenance and Repair

Process Safety Management of Highly Hazardous & Explosive Chemicals. Management of Change

SAFETY BULLETIN. Human interaction with backhoes and excavators

Earthquake Shake Table Original Design by Casey Hagbo Geophysics Major, Class of 2001

PRIVATE EQUITY INSIGHTS

NEW SIX-SEALS CUTTING RING. INTERNATIONAL INDUSTRIAL PATENT Nr of the 10/03/99 FLANKS AND DOES NOT REPLACE THE STANDARD RING CURRENTLY IN USE

Fire Hydrant Troubleshooting

Ve-Lock manufactures Needle Valves from Solid bar stock Materials & all parts details are as below:

Adjusted net profit, stripping out fluctuations in the value of inventories, plunged by almost 50 percent to $11.99 billion.

EXPERT WITNESS AND DISPUTE SUPPORT Property Damage and Business Interruption Insurance Claims

MAGB HEALTH, SAFETY AND ENVIRONMENT GROUP POLLUTION INCIDENT RESPONSE PLAN

This leaflet provides information on

Guidelines for Earthquake Bracing of Residential Water Heaters

Take care with oxygen Fire and explosion hazards in the use of oxygen

Rental Services Temporary Cooling - Flexible Water Hose

Large Personal Injury Claims by Accident Type (Number)

A 53-Year-Old Male Iron Foreman Dies After Fall From Steel Decking

For over 65 years OTECO, Inc. has been providing high quality oilfield equipment to the worldwide oil and gas markets.

MACBlower Model Number: MAC40R MAC60R MAC80R MAC100R. MAC120R MAC150R MAC 200R Serial #

BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS

Open Channel Diffusers

The Steelworker Perspective on Behavioral Safety

HSE and Quality Assurance System

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

SOCALGAS APROACH TO PIPELINE INTEGRITY

Your safety and the safety of others are very important.

with installation dynafact boost GAUGE this manual is for use with systems

Porter Instrument Division

Rail Vehicle Systems IP-241. Rev 07 3/9/ en. Installation and Maintenance Guide. Slack Adjuster Model KRD-482-E and KRD-482-R P/N ,

Optimizing Tank Cleaning Operations

SAMPLE TEST QUESTIONS STEAMFITTER/PIPEFITTER - ITA WEBSITE

EUSNCO309 (SQA Unit Code - FA9F 04) Monitor the installation process for Network Construction Operations

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

Embedded Parts Introduction - Anchors

Installing a Probe. Typical Installation

APPENDIX O. Spill Prevention and Emergency Response Plan. G3 Terminal Vancouver Port Metro Vancouver Project Permit Application APPENDIX O

ALIGNMENT. Pump and Driver Alignment

Steam System Best Practices Condensate System Piping

SUNNDA CORPORATION. Mud Pump Parts & Expendables. Boost Your Bottom Line! Sunnda Corporation

WARNING WARNING TABLE 1.

HELI-DECKS & HELI-PORTS

Passive Anti -Theft System (PATS) Diagnostic Flowcharts. Issue: This bulletin provides diagnostic information for the Passive Anti-Theft System.

OHIO MEDICAL CORPORATION. Medical Gas Outlets. Installation and Maintenance Manual

Workplace Incident Fatalities Accepted by the Workers Compensation Board in 2014

EMERGENCY PREPAREDNESS & RESPONSE PROCEDURE

TBA 100 A Performance Study of the New Generation 100-ton Advanced Technology Rig. Maximilian Trombitas, Product Manager Bauer Deep Drilling GmbH

Diesel Fuel Systems. Injection Nozzles

V47 Series Temperature Actuated Modulating Water Valves

CHIPPING HAMMERS Tabor Place, Santa Fe Springs, California, CA 90670, U.S.A.

Drinking Water Sector - Damage Assessment Report

CASE STUDY HOT WORK CONTROL AND SAFE WORK PRACTICES AT OIL AND GAS PRODUCTION WELLS PARTRIDGE-RALEIGH SMITH COUNTY OILFIELD KEY ISSUES:

StackFlowMaster FPD580 TORBAR probe Stack gas metering systems. Measurement made easy. Introduction. For more information

DRILLING & FOUNDATION EQUIPMENT SAFETY INSTITUTION OF ENGINEERS AUSTRALIA MECHANICAL

Hydraulic control unit series

Series Hose Reels

Root Causes/Failures That Caused the Macondo Well Explosion (BP Oil )

Transcription:

MisMatched Unions have caused fatal accidents! Do you know : what are Weco Unions and who makes them? what are the Dowell Standards? of the potentially fatal hazards? how to eliminate the hazards?

what are they? who makes them? connectors for temporary pipe and flow lines installations. FMC acquired the original Weco company, in the 1950s. The design is old, and manufactured many companies. used in steel and chemical plants, on marine dredging vessels, in strip mines, and in the oil industry. more than a dozen design variations; designated by the nominal pipe diameter and a Fig number i.e. 2 1502.

Fig 100 1000 psi 2 to 8 Fig 211 2000 psi 1 to 4 Fig 602 6000 psi 1 to 4 Fig 1502 15,000 psi 1 to 4 Fig 200 2000 psi 1 to 4 Fig 400 2500 to 4000 psi 2 to 12 Fig 1002 10,000 psi 1 to 6 Fig 2002 20,000 psi 2 or 3 Fig 206 2000 psi 1 to 10 Fig 600 6000 psi 1 to 4 Fig 1003 10,000 psi 2 to 5 Fig 2202 15,000 psi - H 2 S 2 to 3

Dowell Standards Dowell Uses these High Pressure Weco Unions Pressure Rating Standard Service Sour Gas Service. Nominal Pipe Sizes Series Working Test Working Test (dia - inches). 1002 10,000 15,000 7,500 12,000 4, 5 1502 15,000 22,500 10,000 15,000 1, 1½, 2, 3, 2002 20,000 30,000 NA NA 3

The First Hazard A 2 1502 Wing Nut will make up to a 2 602 or 1002 thread half but will fail explosively. 602 1002 Standard Series Working Nominal Pipe Sizes (Figure) Pressure (dia - inches). 100 1,000 2, 2½, 3, 4, 6, 8 200 2,000 1, 1¼, 1½, 2, 2½, 3, 4 206 2,000 1, 1¼, 1½, 2, 2½, 3, 4, 6, 8, 10 207 2,000 3, 4, 6, 8, 10 211 2,000 1, 1¼, 1½, 2, 2½, 3, 4 400 2,500 5, 6, 8, 10, 12 400 4,000 2, 2½, 3, 4 600 6,000 1, 1½, 2, 2½, 3, 4 602 6,000 1, 1¼, 1½, 2, 2½, 3, 4 1002 10,000 1, 1¼, 1½, 2, 2½, 3, 4, 5, 6 1003 10,000 2, 3, 4, 5 1502 15,000 1, 1½, 2, 2½, 3, 4 2002 20,000 2,3 2202 15,000 2, 2½, 3 Potentially Fatal Combinations 1502

The First Hazard A 2 1502 Wing Nut will make up to a 2 602 or 1002 thread half and will hold some pressure! However it will fail explosively. o 4 1/8 Nominal Thread Diameter o 3 Threads per Inch o Standard Acme 2G Thread Form 2 1502 Wing Nut 2 1502 Wing Nut 2 1502 Female Sub 2 602, or 1002 Female Sub o 3 13/16 Nominal Thread Diameter o 3 Threads per Inch o Stub Acme 2G Thread Form

Prevention Destroy 2 602 & 1002 Weco unions or old Guiberson Unions found in your operation. When there is uncertainty (Connecting to other companies equipment) Use the Go No-Go Gage to be sure you have a 1502 Thread Half (Female Sub) Order from Wood Machine - Tulsa Fax : 918-437-0007 Dowell P/N 47990000 No Go Go 2 1502 2 602/1002

Prevention Find the Identification Markings (2 1502) on the Wing Nut Here

Union Gage Ring will go over threads

The Second Hazard Off brand unions may not hold rated pressure. Use only Unions supplied by FMC and in good condition.

The Third Hazard Like 1002 and 602 Unions, a Guiberson thread half will make up to a 1502 wing nut, but will fail explosively. Use only Unions supplied by FMC and in good condition. Guiberson unions have been banned from Dowell operations for more than ten years. Be sure there are none remaining in your operation.

The Fourth Hazard - The FR Male Union Since 1995 FMC offers a Fatigue Resistant Male Union FR Components will fit on Non FR assemblies Mixed assemblies may fail below the rated pressure. Standard Male Union Flat Nut and Segments FR Male Union Tapered Nut and Segments Do not mix FR and Non FR Male Union Parts. See Maintenance Bulletin 957.

Recap Suppliers o There are many suppliers (use only FMC) The Hazards o A 2 1502 Wing Nut will attach to a 2 602 or 1002 Thread Half and hold limited pressure, but will fail explosively. o Off brands may not hold rated pressure (use only FMC). o Beware of old Guiberson connections. o Do not mix FR and non FR Wing Nut (Male Ends) Prevention o Use only 2 1502 unions by FMC, in good condition. o Check before you connect : o Use the Go No-Go Gage to insure a 2 1502 thread half. o Look for 2 1502 on the Wing Nut.

Optional Slides

This 1998 IADC Safety Alert followed a fatal accident on a drilling rig in the USA Gulf of Mexico. Safety Alert ALERT 98-1 High Pressure Lines and Hammer Unions A drill crew was drilling ahead when a third party pressure sensor attached to the stand pipe stopped working. The sensor was made up to the standpipe with a size "602" hammer union rated at 6,000 psi working pressure. The crew removed the faulty sensor and replaced it. The hammer union on the new pressure sensor had a size "1502" wing nut rated to 15,000 psi. The "1502" female threads in the wing nut appeared completely made up to the "602" male threads coming off the standpipe. The mud pumps were engaged and drilling operations resumed. As the mud pump pressure increased, no leaks were detected. Then, at approximately 2,000 psi, the pressure sensor and "1502" wing nut were blown off the standpipe. Fortunately, no one was struck by the projectile or the ensuing stream of drilling fluid. Approximately one barrel of oil-based mud was sprayed on the rig floor before the mud pumps were secured and the standpipe was isolated. The mishap was considered an environmental incident and a significant near miss, which could have resulted in serious injury or death. After investigating the incident, operator offered the following suggestions: 1.Only unions with like threads should be made up. Although mismatched threads may appear made up (as they did in this case), only a portion of the threads are engaged and the union will fail under pressure. 2.Both halves of the union should have the same pressure rating. 3.All pressure lines should be inspected to ensure there are no mismatched unions. This material is presented for information purposes only. Managers & supervisors should evaluate this information to determine if it can be applied to their own situations and practices. From : http://iadc.org/alerts/sa98-1.htm

Weco Unions - Variations Pressure Rating Standard Service Sour Gas Service Series Working Test Working Test Nominal Pipe Sizes 100 1,000 1,500 NA NA 2, 2½, 3, 4, 6, 8 200 2,000 3,000 NA NA 1, 1¼, 1½, 2, 2½, 3, 4 206 2,000 3,000 NA NA 1, 1¼, 1½, 2, 2½, 3, 4, 6, 8, 10 207 2,000 3,000 NA NA 3, 4, 6, 8, 10 211 2,000 3,000 NA NA 1, 1¼, 1½, 2, 2½, 3, 4 400 2,500 3,750 2,500 3,750 5, 6, 8, 10, 12 400 4,000 6,000 4,500 6,000 2, 2½, 3, 4 600 6,000 9,000 NA NA 1, 1½, 2, 2½, 3, 4 602 6,000 9,000 6,000 9,000 1, 1¼, 1½, 2, 2½, 3, 4 1002 10,000 15,000 7,500 12,000 1, 1¼, 1½, 2, 2½, 3, 4, 5, 6 1003 10,000 15,000 7,500 12,000 2, 3, 4, 5 1502 15,000 22,500 10,000 15,000 1, 1½, 2, 2½, 3, 4 2002 20,000 30,000 NA NA 2,3 2202 NA NA 15,000 22,500 2, 2½, 3

Look Alikes - Weco 1502 & 1002 Weco 1502 Hammer Union Assembly Weco 1002 Hammer Union Assembly

Look Alikes - Weco 1502 vs 602 Weco 1502 Hammer Union Assembly Weco 602 Hammer Union Assembly

Look Alikes - Weco 602 & 1002 Weco 602 Hammer Union Assembly Weco 1002 Hammer Union Assembly

Look Alikes - Weco 1502 vs 402 A 2 1502 Wing Nut will, also, attach to a 2 402 Thread Half. Weco 1502 Hammer Union Assembly Weco 400 Hammer Union Assembly