The MEDOS VAD System



Similar documents
Berlin Heart EXCOR Ventricular Assist Device

Section III. Heart Mate II (2 nd Generation) III.41.1 EMT-BASIC EMT-INTERMEDIATE EMT-PARAMEDIC

CALIFORNIA EMERGENCY MEDICAL SERVICES (EMS) MECHANICAL CIRCULATORY SUPPORT (MCS) DEVICES BEST PRACTICES GUIDELINE

Single-Needle Cross-Over System. Brief description

Section Two: Arterial Pressure Monitoring

Children's Medical Services (CMS) Regional Perinatal Intensive Care Center (RPICC) Neonatal Extracorporeal Life Support (ECLS) Centers Questionnaire

Anatomi & Fysiologi The cardiovascular system (chapter 20) The circulation system transports; What the heart can do;

Centro-Matic Automatic Lubrication Systems System Controls

ECMO AND LIFE SUPPORT SYSTEMS QUADROX PLS AND ROTAFLOW HARDWARE AND ACCESSORIES

Waveforms. INTRODUCTION TO THE HEARTWARE WAVEFORM ipad APP

TruPower-Portable-500W. Solar Starter kit

The Hemodialysis Machine Case Study

LC/LCD ranges level controllers

DC Motor control Reversing

IMPORTANT SAFETY INSTRUCTIONS

DCDC-USB. 6-34V 10A, Intelligent DC-DC converter with USB interface. Quick Installation Guide Version 1.0c P/N DCDC-USB

CARDIOHELP INTERFACE PRESENTER (CIP) USER GUIDE GENERAL INFORMATION ABOUT THE CIP:

BLOOD COLLECTION MIXER

HEART MONITOR TREADMILL 12 LEAD EKG

Series 1400 Pulsatile Blood Pumps User's Manual

Milwaukee School of Engineering Case Study: Factors that Affect Blood Pressure Instructor Version

It is recommended that the reader review each medical directive presented in this presentation along with the actual PCP Core medical directive.

Note: The left and right sides of the heart must pump exactly the same volume of blood when averaged over a period of time

Portable Air Conditioner

Design of an Insulin Pump. Purpose of an Insulin Pump:

Stove Guard Kit User Manual

LCD Drawer User Manual

OPL BASIC. Dosing System for Professional Laundry machines. Contents

Ultrafiltration Devices

Model 5511 Filler Controller User s Manual Version 1.1 October 2011

E&I MAINTENANCE ENTRY TEST ENABLING OBJECTIVES. DESCRIBE hazards and precautions taken to avoid injury in the workplace.

Acute heart failure may be de novo or it may be a decompensation of chronic heart failure.

Diagram of components 2. Reducer..3

CARDIOHELP BASIC TRAINING

Suction assembly for l IBC and 205 l drums mm suction tube Suction assembly for tanks mm suction tube.

Heart Failure EXERCISES. Ⅰ. True or false questions (mark for true question, mark for false question. If it is false, correct it.

INTRODUCTION TO EECP THERAPY

How to design an insulin pump

MTS Power Products MIAMI FL ATS-22AG. Automatic Transfer Switch And Control PLC Operator s Manual

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

MEDUMAT Easy CPR The Guiding Emergency Ventilator

Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3A30NA MXZ-4A36NA ATTENTION. English. Français. Español

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

The EasySense unit can detect that the Smart Q Heart Rate Sensor is connected and the range it is set to.

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

User s Manual Before using the inverter, you need to read and save the safety instructions.

ECOCIAT. Domestic hot water heat recovery unit

Dash 18X / Dash 18 Data Acquisition Recorder

OEM MAXNIBP Frequently Asked Questions

Plank 1 Tool: Hypertension Medical Assistant Training (Providence Medical Group)

...een product van BEKA

Elevated heart rate at twelve months after heart transplantation is an independent predictor of long term mortality

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

USB 3.0 Cables. Color. Black Black Black Black Black Black Black Black Black Black

What Are Arrhythmias?

STERILIZERS, LABORATORY DRYING OVENS

Sump Systems for Basements

Chapter 20: The Cardiovascular System: The Heart

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Orientation Guide a product by JOLIFE RevB JOLIFE 2012

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

Dash 8Xe / Dash 8X Data Acquisition Recorder

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

6AV3617-1JC30-0AX1. Type of voltage. UPS connectable (serial) Backup battery. minimum backup duration Memory. Flash / RAM.

Factors Affecting Blood Pressure. Vessel Elasticity Blood Volume Cardiac Output

REMOTE MONITORING AND CONTROL OF THE KAKKONDA GEOTHERMAL POWER PLANTS

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

INTRODUCTORY GUIDE TO IDENTIFYING ECG IRREGULARITIES

Ventricular Assist Device Program. Patient Education Brochure

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

Titan Makina Ltd. Şti Sok. No: 9 Ostim Ankara Tel: Fax: Web:

10000HXL31/15000HXL31/20000HXL31

FEATURES. ! Sealing to IP68 (fully waterproof) Infra-red optical navigation technology

Medical Direction and Practices Board WHITE PAPER

CONTOIL DFM 8EDM. Table of contents. Mounting and operating instructions

Combi switchbox with integrated 3/2 way pilot valve

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Responses to Static (Isometric) Exercise

Freezers - Ultrafreezers. Platilab & Irilab Series

HEAVY WATER LEAK DETECTOR

SMS Alarm. User Manual

Upper Arm Blood Pressure Monitor SC Instructions for use

MODELS 7007 Gorilla Cycle Alarm 7017 Gorilla Cycle Alarm with 2-way pager system way pager system

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

SERVICE MANUAL. Room Air Conditioner Multi Split type Outdoor unit /R410A DC Inverter/

data sheet DONATELLO Rev. I emiss - 25/10/ PRO03 code Automatic tissue processor DONATELLO

Automatic AES Change-Over

PORTABLE AIR CONDITIONER

Series 1400 Pulsatile Blood Pumps User's Manual

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

CG PTFE Diaphragm Liquid Transfer Pump

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

Mureva Assembly surface mounted wiring devices

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

HYDRUS ULTRASONIC METER

Digital I/O: OUTPUT: Basic, Count, Count+, Smart+

HLS Set Advanced Integration meets innovation

Transcription:

The MEDOS VAD System On the market since 1994 more than 500 operations in about 80 heart centres short and medium therm use one of the leading systems in Europe Application field not as a matter of routine, therefore simplicity and efficiency is of particular importance Katrin Rohde, MEDOS Medizintechnik AG

Indications Short to midterm circulation assistance for patients whith myocardiac failure of circulation and failure in conventional therapy postcardiotomy Cardiogenic shock DCM myocarditis Myocardial infarct Acute rejection after TX Acute left and right heart failure

Components MEDOS-VAD cannulae MEDOS-VAD ventricles MEDOS-VAD driving

The ventricle family LVAD 10 ml RVAD 9 ml LVAD 25 ml RVAD 22,5 ml LVAD 60 ml RVAD 54 ml LVAD 80 ml RVAD 72 ml

Describtion of the MEDOS-VAD ventricles sterile disposable pneumatic bloodpump in the following sizes adults children infants RVAD (72 ml; 1/2 ) LVAD (80 ml; 1/2 ) RVAD (54 ml; 1/2 ) LVAD (60 ml; 1/2 ) RVAD (22,5 ml; 3/8 ) LVAD (25 ml; 3/8 ) RVAD (9 ml; 1/4 ) LVAD (10 ml; 1/4 ) RVAD (72 ml; 19/32 ) LVAD (80 ml; 19/32 )

Essential characteristics of the pump I Displacemement pump - extracorporeal - pulsatile Volume flow via enlargement resp. Reduction of the workspace volume the bloodflow is straightened by using a three leaflet bulb valve for inlet and outlet

Essential characteristics of the pump II Optimal outwash of the pumping body and the valves only possible via taking the advantage of using the whole discharge volume Therefor the Full-/Empty- Mode has to be controled and eventually set by medical personell

The conventional drive very stable and solid battery supply 45 minutes for BiVAD Use flow measuring for patients monitoring very large and heavy complicated data acquisition small touch screen EKG triggered mode Katrin Rohde, MEDOS Medizintechnik AG

The Driving-System - Programming via Touch Screen Monitor - monitoring of all user instructions on dialogue menue - Use very safe by easy handling of the system

Frontview of the Driving Touch screen monitor display Alarm Display operation Mains operation Pump On/off Battery Operation General failure Failure in pressure Supply Failure in vacuum supply Failure in battery supply external pressure and vacuum supply Internal pressure and vacuum supply

Backview of the Driving ECG connection Optical interface Sign of type and licence plate 9V Lithiumbattery Connection for LVAD ventilator Connection for RVAD Electrical connection for supply Internal pressure connection for supply Internal vacuum connection for Supply

The Supply System - Internal Akku (2 hrs) - Internal Compressor - injection of pressure and vacuum possible - noisless operation

Frontview of the Supply Operating switch Operating indicator Battery full Indicator for mains operating Failure of supply Battery charging Low battery

Backview of the Supply Pressure connector for external supply Vacuum connector for internal supply Button for lamp testing Potential balance jack Power supply Module connector Mains switch Pressure supply extern Vacuum supply extern ventilator

Diplay after starting the System left pump selection Interlock of the system Right pump selection Softwareversion Softwareversion of the safety computing device

The pressure setting - menue Precalculated ideal value for cardiac output of the left pump Pause left pump Bar graph display forcardiac output Display of the choosen pumps Pause right pump Alarm limit of cardiac output left pump Precalculated ideal value for cardiac output of the right pump Cardiac output acutal value (prediction) left Pump Systolic pressure Alarm limit of cardiac output right pump Cardiac output acutal value (prediction) right Pump Diastolic pressure Systolic pressure Diastolic pressure Systolic time in % frequency Return to starting monitor and pump selection Change to monitor for ECG trigger Change to monitor for setting the alarm limit Setting of choosen values

The MEDOS VAD System support mode not specified 13% RVAD 9% BiVAD 42% LVAD 36% Katrin Rohde, MEDOS Medizintechnik AG

Analysis of Data I Indications Patients n=502 321 male 181 female Age average 42,196 yrs (0,01 67 yrs) 250 200 150 100 50 0 cardiogenic shock cardiogenic Shock and postcard. dcm myocarditis other/not specified postcardiotomy Katrin Rohde, MEDOS Medizintechnik AG

Analysis of Data II Patients n=502 Purpose: Transplantation 123 Weaning 230 Not specified 121 Outcome: Death 216 Weaning 150 Transplantation 135 120 100 80 60 40 20 0 brain death MOF sepsis not specified other Katrin Rohde, MEDOS Medizintechnik AG

the new arterial VAD cannulae cannula with eptfe graft cannula with gelatine coated graft Katrin Rohde, MEDOS Medizintechnik AG

Characteristics of the new arterial cannulae material: PVC (Polyvinylchlorid) Graft of high flexibility by expanted PTFE (Polytetraflouräthylene) and ring amplification Different length and diameters Lower end of the cannula closed with lead-through-assistance Dacron tissue in lead through area

clinical experiences already routinely use for dialysis AV shunts artificial substitution of peripheral vessels animal experiments show the following conclusions: the graft has optimal flexibility Optimal density also at stitch ducts by using stitching material recommended by the manufacturer soft material handling very easy Katrin Rohde, MEDOS Medizintechnik AG

Characteristics of the venous cannulae material: PVC (Polyvinylchlorid) Wire reinforced upper third Different length, diameter and angles (Standard 135 ) Upper end with blood taking basket as well as seam elevation for fixation by dubble pursestring suture Lower end of the cannula closed with lead-through-assistance Dacron tissue in lead through area

avaliability arterial cannula with eptfe graft inner diameter [mm] article number connection for VAD ventricle 5,0 ME 656 B0053 1/4 9/10 ml 6,0 ME 656 B0063 1/4 9/10 ml 8,0 ME 656 B0083 1/4 9/10 ml 8,0 ME 656 B0084 3/8 22,5/25 ml 10,0 ME 656 B0104 3/8 22,5/25 ml 10,0 ME 656 B0105 1/2 54/60 ml 72/80 ml 13,0 ME 656 B0135 1/2 54/60 ml 72/80 ml Katrin Rohde, MEDOS Medizintechnik AG

avaliability arterial cannula with gelatine coated graft ínner diameter [mm] article number connection for VAD ventricle 6,0 ME 6560S 0063 1/4 9/10 ml 8,0 ME 6560S 0083 1/4 9/10 ml 8,0 ME 6560S 0084 3/8 22,5/25 ml 10,0 ME 6560S 0104 3/8 22,5/25 ml 12,0 ME 6560S 0125 1/2 54/60 ml 72/80 ml 14,0 ME 6560S 0145 1/2 54/60 ml 72/80 ml Katrin Rohde, MEDOS Medizintechnik AG

Our Future: The MEDOS HD eight Katrin Rohde, MEDOS Medizintechnik AG

specifications of the MEDOS HD eight mobile drive battery supply up to 4 hours plus emergency energy (about 1 hour) automatic mode via flow measurement improved flow measurement size: 340x315x134 (BTH) weight: 9,8 kg easy data acquisition large touch screen 640x480 integrated into the console Katrin Rohde, MEDOS Medizintechnik AG

Conventional drive vs. HD eight Application Operating Mode Biventricular mode Portability Conventional drive - LVAD, RVAD, BiVAD - Ventricle Size 9 ml to 80/72 ml - Fixed-rate mode - EKG mode - push push operation - emergency battery supply up to 45 minutes - size: 1150x700x750 mm - weight: 115 kg HD eight - LVAD, RVAD, BiVAD - Ventricle Size 9 ml to 80/72 ml - Fixed-rate mode - Automatic modus = first fill then empty -> var. rate - push push operation - alternating operation - - battery supplied up to 4 h plus emergency energy >= 1h - size: 340x315x134 (BxTxH) mm - weight: 9,8 kg - environmental fit: explosion proof - waterproof Katrin Rohde, MEDOS Medizintechnik AG

Conventional drive vs. HD eight Securities Technical Data User interface Conventional drive - processor controlled security system with integrated emergency power - optic and acoustic warning signals on fail of functions - beating frequency: 40 to 180 BPM - beating volume: - pressure left/right: 300 mmhg max - vacuum left/right: -99 mmhg max - battery supplied mode: emergency 45 min max - operating voltage: 2 x 12V intern, DC 24V/ 230 V, others avaliable - push push operation HD eight - Integrated autonomous backups Moitoring and alarm possibilities: flow, pressure incl. tube buckling - - minimal false handling because of user guide and integrated ventricle typing - beating frequency: 35 to 130 BPM - beating volume: 160 ml max. - pressure left/right: 400 mmhg max - vacuum left/right: -200 mmhg max - battery supplied mode: 4 h max plus 1h memergency energy - operating voltage: 12V intern, DC 12V / 110-240 VAC extern - push push operation - alternating operation Katrin Rohde, MEDOS Medizintechnik AG

Patient 1: 43 years cardiogenic shock 60 min. reanimation Implantation of LVAD transplantation after 57 days

Patient 2: 15 years DCM Implantation of LVAD (60ml) Transplantation after 14 days