FREQUENCY RESPONSE ANALYZERS



Similar documents
MATRIX TECHNICAL NOTES

MODEL 1211 CURRENT PREAMPLEFIER

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies

SIGNAL GENERATORS and OSCILLOSCOPE CALIBRATION

Contents. Safety Warnings... 1

VME IF PHASE MODULATOR UNIT. mod

Impedance 50 (75 connectors via adapters)

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

SL Series AC and DC Electronic Loads

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT BIT DIFFERENTIAL ADC WITH I2C LTC2485 DESCRIPTION

PCM Encoding and Decoding:

RF Measurements Using a Modular Digitizer

APSYN420A/B Specification GHz Low Phase Noise Synthesizer

INTRODUCTION. Please read this manual carefully for a through explanation of the Decimator ProRackG and its functions.

User's Guide. Integrating Sound Level Datalogger. Model Introduction

EXPERIMENT NUMBER 5 BASIC OSCILLOSCOPE OPERATIONS

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

i410/i1010 AC/DC Current Clamp

Active Vibration Isolation of an Unbalanced Machine Spindle

Reading: HH Sections , (pgs , )

Power Amplifier Gain Compression Measurements

AFG-100/200 series USB Modular Arbitrary Function Generator. Date: Oct, 2014

Performing Amplifier Measurements with the Vector Network Analyzer ZVB

Agilent AN 1316 Optimizing Spectrum Analyzer Amplitude Accuracy

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

Jeff Thomas Tom Holmes Terri Hightower. Learn RF Spectrum Analysis Basics

RF Network Analyzer Basics

OPERATIONAL AMPLIFIERS. o/p

Lab 1: The Digital Oscilloscope

FFT Spectrum Analyzers

Load Cell Amplifier Module. Instruction Manual LCA

MICROPHONE SPECIFICATIONS EXPLAINED

PagePac PAGEPAL V

MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card

Prepared by: Paul Lee ON Semiconductor

LABORATORY 2 THE DIFFERENTIAL AMPLIFIER

User s Guide DDS-3X25 USB ARBITRARY FUNCTION GENERATOR

Department of Electrical and Computer Engineering Ben-Gurion University of the Negev. LAB 1 - Introduction to USRP

CS4525 Power Calculator

Timing Errors and Jitter

LogicLab s.r.l Via della valle Carate Brianza (MI) Tel Fax

Analogue/Digital Analogue and Differential Oscilloscopes

User Manual. CFG253 3 MHz Function Generator

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

VCO Phase noise. Characterizing Phase Noise

PIN CONFIGURATION FEATURES ORDERING INFORMATION ABSOLUTE MAXIMUM RATINGS. D, F, N Packages

PERF10 Rubidium Atomic Clock

LM 358 Op Amp. If you have small signals and need a more useful reading we could amplify it using the op amp, this is commonly used in sensors.

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

[F/T] [5] [KHz] [AMP] [3] [V] 4 ) To set DC offset to -2.5V press the following keys [OFS] [+/-] [2] [.] [5] [V]

ECONseries Low Cost USB DAQ

Designing the Solution for Electrochemistry Potentiostat/Galvanostat І Battery Cycler І Fuel Cell Test Station І

Model DB 750 Tube Bass Head

Agilent 8904A Multifunction Synthesizer dc to 600 khz

Physical Specifications (Custom design available.)

Section 3. Sensor to ADC Design Example

Building a Simulink model for real-time analysis V Copyright g.tec medical engineering GmbH

Electrical Resonance

Current Probes. User Manual

ANALYZER BASICS WHAT IS AN FFT SPECTRUM ANALYZER? 2-1

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

Outer Diameter 23 φ mm Face side Dimension 20.1 φ mm. Baffle Opening. Normal 0.5 Watts Maximum 1.0 Watts Sine Wave.

LM1036 Dual DC Operated Tone/Volume/Balance Circuit

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Use and Application of Output Limiting Amplifiers (HFA1115, HFA1130, HFA1135)

One Port Network Analyzer

Op Amp Circuit Collection

PicoScope 6000A/B Series

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

HOW TO GET 23 BITS OF EFFECTIVE RESOLUTION FROM YOUR 24-BIT CONVERTER

Unattended Answering Device Instruction Manual

Innkeeper PBX. Desktop Digital Hybrid. User Guide. JK Audio

khz to 2.7 GHz Spectrum Analyzer

Understanding Dynamic Range in Acceleration Measurement Systems. February 2013 By: Bruce Lent

POCKET SCOPE 2. The idea 2. Design criteria 3

************* OWNER'S MANUAL BAMF800/2 BAMF1250/2 BAMF1800/2 BAMF2200/2 BAMF2600/2 BAMF1200/4 BAMF1600/4 BAMF2000/1D BAMF4000/1D BAMF5500/1D

Voltage. Oscillator. Voltage. Oscillator

Programmable Single-/Dual-/Triple- Tone Gong SAE 800

DEVELOPMENT OF DEVICES AND METHODS FOR PHASE AND AC LINEARITY MEASUREMENTS IN DIGITIZERS

A Guide to Calibrating Your Spectrum Analyzer

EDD-600 FLOW TOTALIZER RATE INDICATOR OPERATION MANUAL. P.O. Box Odessa, Texas USA.

AC Measurements Using the Oscilloscope and Multimeter by Mr. David Fritz

Lab #9: AC Steady State Analysis

How To Use A Sound Card With A Subsonic Sound Card

Turbo X channel UHF true diversity

EECC694 - Shaaban. Transmission Channel

Jeff Thomas Tom Holmes Terri Hightower. Learn RF Spectrum Analysis Basics

CBS RECORDS PROFESSIONAL SERIES CBS RECORDS CD-1 STANDARD TEST DISC

CQM1-SF200/CS1W-SF200

1.44 kw Programmable DC Power Supplies XLN Series

UNINTERRUPTIBLE POWER SUPPLIES >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES

INSTRUCTION MANUAL MODEL PCD-88

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

MODEL 2202IQ (1991-MSRP $549.00)

OMNIYIG. .5 TO 2 GHz, 1 TO 4 GHz, 6 to 18 GHz Thin Film YIG-TUNED OSCILLATORS OUTLINE DIMESIONS MOUNTING SURFACE GND +15V + TUNE - HTR HTR

Ordering Part Numbers: Universal Signal Converter: USC-CVB Universal Signal Converter with a 4-20mA input and +/- 10V output: USC-CVB225-B10V

Dayton Audio is proud to introduce DATS V2, the best tool ever for accurately measuring loudspeaker driver parameters in seconds.

Features, Benefits, and Operation

Transcription:

FREQUENCY RESPONSE ANALYZERS Dynamic Response Analyzers Servo analyzers When you need to stabilize feedback loops to measure hardware characteristics to measure system response BAFCO, INC. 717 Mearns Road P.O. Box 2428 Warminster, Pennsylvania 18974 Tel. No. 215-674-1700 Fax No. 215-675-1571 e-mail bafco@bafcoinc.com

SPECIFICATIONS & FEATURES GENERAL All Bafco analyzers furnish you the measurements for defining the dynamic response and stability of feedback control systems. They operate with optimum speed and with automatic noise and harmonic rejection by Fourier analysis. Test signals have low distortion and are without discontinuities. We offer several models, which are different in the range of frequency thru which they operate; in their measurement to one point of the system or across any block or blocks of the system; and whether they are to be used manually for point by point measurements or automatically for plotting. Here is a guide to these models. ANALYZER TYPES FREQ. RANGE OPTIONS APPLICATIONS SINGLE CHANNEL: MANUAL OPERATION, POINT-BY-POINT 911A2D Universal F.R.A.: very fast operation. Includes carrier and outputs of square and triangle waveforms. Dual digital readout of amplitude ratio (db) and phase. 0.01 to 10,000 Hz DC ~ Log Freq. DC ~ Amp Ratio (db ± 60). Universal: all feedback control systems (DC and carrier) for very rapid results. TWO CHANNEL: MANUAL OPERATION, SWEEP FREQUENCY 916A 916AXH Display & plots amplitude in db of each channel, amplitude ratio and phase shift. Recorder calibrate and pen lift signals supplied. 0.005 to 10 KHz 0.10 to 100 KHz Carrier 50 to 10 KHz Universal: all dynamic response measurements for direct plotting of results TWO CHANNEL: PROGRAMMABLE 920B Programmable Two Channel Frequency Response Analyzer IEEE-488 Bus Compatible 0.005 to 10KHz Carrier 50 to 10 KHz As 916A, except 12 bit word programmable with multiplexed digital data lines and analog outputs. I.E.E.E. 488 Bus Compatible Frequency Accuracy: ±1% of value db Accuracy: ±0.15 Output Signal: Sine, Square, triangle, D.C. & Suppressed Carrier Modulation when ordered. Amplitude: 10 V.F.S., current to ±30 M.A., 1% accuracy D.C. Offset: up to ±10 V. Distortion: 1% RMS at F.S., 2% RMS at 10% of F.S. Amplitude Accuracy: ±1% F.S. Phase Accuracy: ±1 Source Impedance: 5 Ohms COMPUTER PERIPHERALS: Magtape drives, disc memory head position systems. D.C. POWER SUPPLIES: Stability of switching regulator high efficiency power supplies. SIMULATORS: Matching of response of multi-channel actuator systems. AIRCRAFT: Autopilot, electrohydraulic valve controls, guidance systems. ENGINES: Engine response characteristics speed, fuel flow and inlet configuration control systems. Wherever the dynamic characteristics of hardware, structures or systems are needed, either for component or process improvement or for design of controls and networks for stability.

911A2D SINGLE CHANNEL POINT-BY-POINT ANALYZERS WITH DUAL READOUTS FREQUENCY RANGE 0.01 TO 10,000 Hz MEASURES & DISPLAYS: Dual 3 ½ Digit Readouts of: Phase of the fundamental component of the Return Signal with respect to the Test Signal in degrees to the nearest 0.1 over ±180 DB Amplitude Ratio in db of the fundamental component of the return Signal to the amplitude of the Test Signal. ±66 db to nearest 0.1 db. Amplitude of fundamental component of the Return Signal as a percent of full scale sensitivity (volts peak). 0 to 150 % to nearest 0.1%. AUTOMATICALLY REJECTS: Harmonics (Distortion) & Noise on the Return Signal using Fourier Integral Analysis. FAST OPERATION: A new result every 1½ cycles of test frequency to 1.0 hz. Maximum 2.5 sec/reading above 1.0 hz. REPEAT MODE OF OPERATION: Automatic restart of Analysis Cycle. Bounce in results shows uncertainty due to noise. SMALL SIZE: 5¼ High, 14¾ Wide, 13 Deep TEST SIGNAL: Low Distortion, High Current, Precise Amplitude Setting, D.C. Offset, Run-Reset switch for Fast Test. Wave shape SIN, Triangle & Square Wave. RETURN SIGNAL: Balanced, High Input Impedance, Manual Adjust of D.C. Offset, Full Scale Ranges from 25 volts to 100 mv. ACCURATE: ±1, ±1% CARRIER OPERATION COMPLETE OPTIONS: Log Frequency; DB Ratio of Return Signal/Test Signal.

916A AND 916AXH UNIVERSAL TWO CHANNEL, SWEEP OPERATION FOR PLOTTING 916A Frequency Range: 0.005 to 10 KHz 916AXH Frequency Range: 0.1 to 100 KHz WITH AUTOMATIC SIGNAL AMPLITUDE CONTROL DESCRIPTION: The Automatic Signal Amplitude Control has three modes of operation: when selected, it holds the Amplitude of Channel 1 or 2 constant over the entire frequency range, or it holds the lower of the two amplitudes constant. (Especially useful in Power Supply Switching Regulator Circuit Analysis.) When these functions are not required, the Analyzer operates in normal mode. The Amplitude Servo keeps tests within the linear range of operation and reduces operator intervention in achieving accurate results. FEATURES: Holds the selected channel amplitude constant within ±0.1 db over the entire frequency range Completely automatic. Uniformly effective and stable, even with high noise levels present Continuous sweep over any portion of 6 decades Displays and plots amplitude ratio (db) Phase shift vs. log frequency Provides plotter calibrate and penlift signals Open loop results from closed loop test Automatic Gain Control 80 db Dynamic range in each channel, with 72 db range in amplitude servo operation Direct operator control of all functions sweep speed, sweep sense, integrate time High noise Harmonic rejection Fourier integral analysis Plug in carrier operation option Low distortion, high current test signal with DC Offset, sine, triangle, or square wave. MEASURES & DISPLAYS: Amplitude Ratio Ch #2/Ch #1 in db Phase Shift /Ch #2 - /Ch #1 in degrees Amplitude Ch #1 in db Amplitude Ch #2 in db AUTOMATICALLY REJECTS: Harmonics (Distortion) & Noise on the Return Signals using Fourier integral Analysis. Operator selects Integration Time (2 Ranges) AUTOMATIC GAIN CONTROL SYSTEM: With 80 db Dynamic range in each Channel. Operates with noise as bad as eight times signal amplitude. SWEEPS & PLOTS: Amplitude Ratio (db) and Phase Shift vs. Log Frequency. Continuous Log Sweep from Start to Stop Frequency over any frequency span up to the entire 6 decade frequency range. Sweep Speed Control from 2 sec. /decade to 10,000 sec. /decade. Change as required during a run. Sweep Down to retrace portion of sweep. DIGITAL METER READING: of all outputs, of DC Offset on Test signal, and of Frequency. CALIBRATE LEVELS: Phase, Amp. Ratio for X-Y 1 Y2 plotter (momentary switches) ON-OFF SWITCH OF TEST SIGNAL: for short test run, and for fast shutoff. A.C. COUPLING: of Return Signals to reject ±100 volts DC on return signal. SMALL SIZE: 5 ¼ high, Lightweight, Low Power Consumption. ACCURATE: ±1, ±.15 db OPTIONS: Carrier.

MODEL 920B PROGRAMMABLE TWO CHANNEL FREQUENCY RESPONSE ANALYZER IEEE-488 BUS COMPATIBLE FREQUENCY RANGE 0.005 TO 10,000 Hz THE MODEL 920B FURNISHES A PROG RAMMING CAPABILITY IN A TWO CHANNEL FREQUENCY RESPONSE ANALYZER THAT PROVIDES TOTAL O PERATING CAPABILI TIES. IN PROGRAMMABLE MODE: Choice of IEEE-488 Bus Control or a 12 Bit Parallel Entry Word to program the analyzer by selection of input connector. Multiplexed digital data lines for automatic analysis. Programs with digital printout or plotting. Direct digital readouts of results. Outputs for analog plotters. IN MANUAL MODE: Simple setup and operation from front panel controls. Requires no auxiliary equipment. Direct reading results on digital displays. Analog outputs simultaneously available. PROGRAMMABLE FUNCTIONS: Frequency Amplitude of test signal Signal select-sin, square or triangle DC Offset Integration time X1 or X5 Input filter In, Out Present gain In, Out Unity gain In, Out DC Reject Reset analyzer, test signal or both. Carrier operation optional Channel I DC or Demod. Channel II DC or Demod. A/D convert signal for data readout.

MODEL 920B (CONTINUED) SPECIFICATIONS FREQUENCY RANGE -.005 HZ to 10 KHZ Accuracy is within ±1% of programmed value. TEST SIGNAL AMPLITUDE 10 volt & 1 volt full scale ranges with a part in 1000 resolution. Accuracy is within ±1% of programmed value. SINE WAVE DISTORTION Under 1% total RMS at F.S. AMPLITUDE RATIO Dynamic range - ±80db Accuracy (to S/N = 1/1) Channels I and II inputs (signal) Error 2.5 MV to 10 volts Peak ±.15db (±72db) 1.0 MV to 2.5 MV Peak ±.20db (±80db) PHASE SHIFT Degrees ±180 Meter Direct reading over ±180 to nearest 0.1 DC Voltage ±1.80 Volt. = ±180 Accuracy (to S/N = 1/1) (signal) Error 2.5 MV to 10.0 Volt Peak ±1 1.0 MV to 2.5 MV Volt Peak ±1.5 Worse Case Error - ±2 Usual Errors ±0.75 INCLUDES: High Pass Input Filter for D.C. offset reject. Gain of Input Amplifier 1 V/V to 1024 V/V In X2 steps. 2 nd High Pass Input Filter. Break frequency matched to Frequency Range in use. Increases low frequency noise rejection AUTOMATIC GAIN CONTROL: Maintains each channel s sensitivity to prevent Overload, or Underload. Insures that incorrect results due to noise overload do not reach output. Gives excellent results at S/N as bad as 1/8. Continue to operate at S/N = 1/10. COORDINATE COMPUTER Converts Cartesian Coordinate output of Fourier Integral to Polar Coordinates with Read-Hold on all outputs. Solves for AMP. Ch #1 (db), AMP. Ch #2 (db), AMP. Ratio (db), Phase Shift. SUMMARY: These subsystems combine to provide a complete automatic two channel Frequency Response Analyzer. The Model 920B is further designed to: Completely define sharp resonances in the item under test. Operate accurately under very adverse signal-to-noise ratios. Reject D.C. and low frequency upsets more effectively than Fourier Integral Analysis alone (high pass input filters built in). Clearly show the limits of confidence that can be placed on the results by the variations in the answer from one cycle of analysis to the next.

PRICE LIST NEW UNITS FREQUENCY RESPONSE ANALYZERS and ACCESSORIES Effective January 1, 2014 MODEL BASIC SPECIFICATION PRICE 911A2D Single Channel, 0.01 to 10,000 HZ, With dual $17,911.00 digital readout of phase, amplitude and Amp. Ratio (in DB). Includes carrier. 916A Universal Two Channel sweep Frequency $21,916.00 Response Analyzer AGC-80DB. Extended Sweep. 0.005 Hz to 10 KHz 916AXH 920B 0.1 HZ to 100,000 HZ. OPTIONS: For 916A Carrier For 916AXH Carrier Programmable Two Channel Frequency Response Analyzer 0.005 Hz to 10 KHz IEEE-488 Bus Compatible $25,916.00 $2,140.00 $2,140.00 $26,920.00

TERMS & CONDITIONS FREQUENCY RESPONSE ANALYZERS PRICES: ALL PRICES ARE F.O.B. PLANT, WARMINSTER, PENNSYLVANIA, U.S.A. THEY DO NOT INCLUDE ANY FEDERAL, STATE OR LOCAL SALES, USE, EXCISE OR SIMILAR TAXES THAT MAY BE IN EFFECT. ALL PRICES ARE SUBJECT TO CHANGE WITHOUT NOTICE, ALTHOUGH FORMAL PRICE QUOTATIONS ARE PROTECTED FOR A PERIOD OF 45 DAYS. BAFCO CAN SUPPLY A FIRM QUOTATION FOR ANY PERIOD, ON REQUEST. TERMS: NET 30 DAYS UPON APPROVAL. SPECIFICATION CHANGES: BAFCO, INC. RESERVES THE RIGHT TO DISCONTINUE ANY ITEM WITHOUT NOTICE, AND TO CHANGE SPECIFICATIONS OF ANY INSTRUMENT OR ANY PART AT ANY TIME AND WITHOUT INCURRING OBLIGATIONS TO INCORPORATE NEW FEATURES IN INSTRUMENTS OR PARTS PREVIOUSLY SOLD. WARRANTY: WE WARRANT EACH NEW INSTRUMENT MANUFACTURED BY US TO BE FREE FROM DEFECTS IN MATERIAL AND WORKMANSHIP. OUR OBLIGATION UNDER THIS WARRANTY SHALL BE LIMITED TO REPAIRING OR REPLACING AT OUR FACTORY ANY INSTRUMENT OR PART THEREOF WHICH WITHIN ONE YEAR AFTER SHIPMENT TO THE ORIGINAL PURCHASER, IS RETURNED TO US PREPAID AND WHICH OUR EXAMINATION SHALL DISCLOSE TO HAVE BEEN THUS DEFECTIVE. THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER OBLIGATIONS OR LIABILITIES ON OUR PART, CONTRACTUAL OR OTHERWISE, EITHER TO THE ORIGINAL PURCHASER OR NAY OTHER PERSON. WE ASSUME NO LIABILITY FOR CONSEQUENTIAL DAMAGES OF ANY KIND EXCEPT WHERE THIS EXCLUSION IS PROHIBITED. THE PURCHASER, BY PLACING AN ORDER WITH US SHALL BE DEEMED TO ASSUME ALL LIABILITY FOR ANY AND ALL DAMAGES CONSEQUENTIAL UPON THE USE OR MISUSE OF THE EQUIPMENT BY THE PURCHASER, ITS EMPLOYEES OR OTHERS. NO AGENT IS AUTHORIZED TO ASSUME FOR US ANY LIABILITY EXCEPT AS ABOVE SET FORTH. THIS WARRANTY APPLIES TO ALL BAFCO, INC. MANUFACTURED EQUIPMENT. THE WARRANTIES WE RECEIVE FROM THE ORIGINAL MANUFACTURER OF OTHER THAN BAFCO EQUIPMENT WILL BE PASSED ON TO THE PURCHASER.