Code Compliance Guideline: Swimming Pool Chemicals



Similar documents
General Fire Code Requirements Within Commercial Tenant Spaces

OREGON FIRE CODE Interpretations and Technical Advisories

Section III Hazardous Materials Management

Dennis Fire Department Fire Prevention Mark Dellner Fire Chief

FLAMMABLE AND COMBUSTIBLE LIQUIDS. n OSHA Changes

SPILL PREVENTION AND RESPONSE PLAN TEMPLATE FOR BUSINESSES IN DAYTON S SOURCE WATER PROTECTION AREA

FDNY C14 Certificate of Fitness Quiz

Requirements for Hydrogen Storage and Use

All You Ever Wanted to Know About Fire Extinguishers...

FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS

1. Site plans assist the Fire Department to determine where a potential spill can be contained. The detailed site plan shall include the following:

Town of Bellingham Fire Department

Hazardous Waste Determination and Management Plan

FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS November 2011

A Code Review for Emergency Generators and Indoor Use of Portable Generators

Waste Oil Collection / Storage

The following definitions apply with regard to requirements specified in this document:

CANTON FIRE DEPARTMENT

Notes. Material 1. Appropriate Flammable Liquids

LABORATORY SAFETY INSPECTION CHECKLIST

Civil Engineering Sector Labour-Management Health and Safety Committee

ALLEGANY WIND POWER PROJECT CONSTRUCTION SPILL PREVENTION PLAN

EMERGENCY ACTION, EVACUATION AND FIRE PREVENTION SAFETY PROGRAM

TYPICAL FIRE SAFETY INSPECTION VIOLATIONS

HealthandSafetyOntario.ca. Introduction. Storage Containers. Storing Flammable Liquids

Guide on the Segregation, Packaging, Labelling and Storage of Laboratory Chemical Wastes for Schools

Flammable Liquids 29 CFR

BP WIND ENERGY POLICIES AND PROCEDURES

CAL FIRE/San Luis Obispo County Fire Fire Prevention Bureau

Sample Written Program. For. Flammable Liquids

UCL FIRE RISK ASSESSMENT POLICY& ARRANGEMENTS

Exit Routes, Emergency Action Plans, Fire Prevention Plans, and Fire Protection. OSHA Office of Training and Education 1

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

c. As mandated by law, facilities must obtain and maintain valid zoning permits as well as permits for intended use.

General Safety & Health Standards Published by the Division of Building Safety In Cooperation with the Idaho Industrial Commission

Laboratory Safety and Environmental Health Assessment Program

Minnesota State Department of Public Safety

Flammable and Combustible Liquids. Slide 1 (of 23)

OCFRD TENT STANDARD This Standard operates under the authority of Orange County, Florida Ordinance and State Statutes.

SILICON VALLEY CLEAN WATER. May 2015

A. Fire Protection Plan. B. Access and Parking

FACILITY FIRE PREVENTION AND EMERGENCY PREPAREDNESS INSPECTION CHECKLIST

HOT WORK PERMIT PROCEDURES

Spray Booth Guideline

Emergency Evacuation Plan: 232 King St.

ABC CIRCUITS 10 Circuit Drive Circuit Town, IN SLUG CONTROL PLAN

ALVERNIA UNIVERSITY OSHA REGULATION: 29 CFR WELDING, CUTTING, AND BRAZING ( HOT WORK ) SECTION: 3600

Flammable Liquids Storage

MONARCH FIRE PROTECTION DISTRICT

FIRE AND SAFETY REGULATIONS

Regulated Waste Storage

HERNANDO COUNTY FIRE ALARM GUIDELINES

Bold items are particular to the City of Euless

SECTION THREE CONSTRUCTION CODES

ACTIVITY NAME. Training Requirements for Spill Prevention Control and Countermeasures (SPCC) 40 CFR Part 112 Naval Air Station Corpus Christi Texas

Emergency Procedures IF YOU DISCOVER A FIRE. Upon discovering a fire: the following steps are to be taken:

BUILDING INSPECTORS INSPECTION FORM FOR CHILD CARE CENTERS

ENVIRONMENTAL HEALTH AND SAFETY HAZARDOUS MATERIALS MANAGEMENT PLAN

Name Of Occupancy Date. Yes No Describe

ADMINISTRATIVE SERVICES MANUAL

Pollution Prevention And Best Management Practices For Dry Cleaners Operating In Broward County

CONSTRUCTION FIRE SAFETY PLANNING GUIDELINES

Rancho Cucamonga Fire Protection District Prevention Bureau Standard

FIRE SAFETY SELF-INSPECTION FORM FOR CULTURAL INSTITUTIONS. 1. All Floors (inspect from top floor to basement): Yes No

Improper storage of fuel on construction sites will increase the risk of water pollution that may occur as a result of leaks or spills.

SELF-INSPECTION PROGRAM FOR FIRE PROTECTION EQUIPMENT

Suffolk County Department of Health Services. Division of Environmental Quality

SPILL CONTAINMENT AND CONTROL PLAN

CITY OF WASHINGTON SPILL PREVENTION, CONTROL AND COUNTERMEASURE PLAN

INTERNATIONAL FIRE CODE SECTION 3103 TEMPORARY TENTS AND MEMBRANE STRUCTURES

527 CMR: BOARD OF FIRE PREVENTION REGULATIONS 527 CMR 14.00: FLAMMABLE AND COMBUSTIBLE LIQUIDS, FLAMMABLE SOLIDS OR FLAMMABLE GASES

The Fire Safety Manager at (FAX ) can answer any questions or provide a set of fire code information.

UDOT SPILL PREVENTION and RESPONSE PLAN for CONSTRUCTION SITES

MAGB HEALTH, SAFETY AND ENVIRONMENT GROUP POLLUTION INCIDENT RESPONSE PLAN

Mechanical Systems Competency 1.20

THE CORPORATION OF THE CITY OF COURTENAY BYLAW NO A bylaw to amend Storm Sewer Bylaw No. 1402, 1986

Special events and tents Fire and life safety requirements

PLAN APPLICATION HAZARDOUS MATERIALS USE AND SPILL PREVENTION CONTROL (HMPC) PLAN

Flammable Liquids Storage

9/15/2011. Presented by: Jason Reason, CIH, CSP, CHMM Senior Industrial Hygienist Indiana Occupational Safety and Health Administration

DRAFT Guidelines for Manually Diverting Outdoor Wastewater to the Sanitary Sewer

Texas Department of Insurance. Fire Safety. Provided by. Workers Health & Safety. Pub. No. HS01-028D (7-08)

Ethanol Vehicle and Infrastructure Codes and Standards Citations

Portable Fire Extinguisher Presentation

FIRE SAFETY SELF-INSPECTION FORM FOR CULTURAL INSTITUTIONS

Model Safety Program

The following definitions apply with regard to requirements specified in this document:

Fire Extinguishers. A Health and Safety Guideline for Your Workplace. Fire Extinguishing Methods. Introduction. Types of Extinguishers

Safety Inspections and Sample Safety Inspection Checklists

LOS ANGELES CITY FIRE DEPARTMENT

Inspection, Testing and Maintenance

How To Safely Handle A Spill

COMPRESSED GASES. 1.2 The contents of each cylinder and container must be clearly identified (by tag or stamp) on the cylinder.

Restaurant & café guide

Transcription:

A publication of Fairfax County, Virginia CODE COMPLIANCE GUIDELINE SWIMMING POOL CHEMICALS AND FIRE SAFETY REQUIREMENTS RELATED TO POOL OPERATIONS This publication outlines the Fire Prevention Code requirements related to the dispensing, storage, and use of common swimming pool chemicals (e.g., corrosive liquids and oxidizers) at water recreation facilities such as public swimming pools and waterparks located in Fairfax County and the towns of Clifton, Herndon, and Vienna. Fire safety requirements common to water recreation facilities and the roles and responsibilities of pool operators and life guards are also addressed in this publication. Questions regarding the content of this publication should be directed to the Fire Inspections Branch at 703-246-4849 during regular office hours, Monday thru Friday, 8:00 a.m. to 4:30 p.m. HAZARDOUS MATERIALS (Pool Chemicals) Office of the Fire Marshal Fire Inspections Branch 10700 Page Avenue Fairfax, Virginia 22030 Telephone: 703-246-4849 Fax: 703-246-6042 TTY: 711 or 1-800-828-1120 Material Safety Data Sheets (MSDS) Required. MSDS for all hazardous materials shall be readily available on the premises as a paper copy. MSDS should be stored in a non-hazardous area such as an office or life guard room and not in pool chemical dispensing and storage areas. It is suggested that MSDS be kept in a dedicated binder or folder which is clearly marked "MSDS" for easy identification. MSDS can be obtained from the pool chemical supplier. (407.2) Individual Container Identification Required. Individual containers of hazardous materials, cartons or packages shall be clearly marked or labeled in accordance with applicable federal regulations. (407.3) All containers and packages should be properly sealed or closed and safely stored in accordance with the MSDS to prevent leakage, exposure or possible injury. In addition, containers should be safety stored on spill containment decking or pallets. NFPA 704 Hazard Identification Signs Required. NFPA 704 hazard identification signs shall be provided at entrances to locations where pool chemicals are stored, dispensed, used or handled in quantities requiring a permit and at specific entrances and locations designated by the fire code official. (5003.5) NFPA 704 signs shall be numbered and labeled for the hazards associated with the pool chemical(s). Numbering and labeling information is typically found in the MSDS. Where many chemicals are present, a single sign shall summarize the maximum ratings contributed by the material(s) in each category and the special hazard category for the building and/or the area. NFPA 704 signs may be obtained through industrial safety equipment suppliers, sign fabricators, or sign supply companies. (See Example on Page 2) 1 of 5

NFPA 704 Sign Maintenance & Visibility. NFPA 704 signs and markings shall not be obscured or removed, shall be in English as a primary language or in symbols permitted by the Fire Prevention Code, shall be durable, and the size, color and lettering shall be approved. (5003.6) NFPA 704 Hazard Identification Sign and Markings TOP OF SIGN RED BLUE YELLOW WHITE Separation of Incompatible Materials Required. Incompatible materials are materials that, when mixed, have the potential to react in a manner which generates heat, fumes, gases or byproducts which are hazardous to life or property. Material incompatibility information is typically found in the MSDS. All materials in storage and storage of materials that are incompatible with materials in use shall be separated when the stored materials are in containers having a capacity of more than 5 pounds or 1/2 gallon. Separation of incompatible materials shall be accomplished by any of the following: (5003.9.8) 1. Segregating incompatible materials in storage by a distance of not less than 20 feet. 2. Isolating incompatible materials in storage by a noncombustible partition extending not less than 18 inches above and to the sides of the stored material. 3. Storing liquid and solid materials in approved hazardous material storage cabinets. 2 of 5

Security of Hazardous Materials Required. Storage, dispensing, use and handling areas shall be secured against unauthorized entry and safeguarded in an approved manner. (5003.9.2) Secondary Containment Required for Corrosive Liquids. Secondary containment is a level of containment that is external to and separate from primary containment. Buildings, rooms, or indoor areas with a total quantity of corrosive liquids (e.g., Sodium Hypochlorite, Muriatic Acid) dispensed or used in open systems exceeding 100 gallons shall be provided with secondary containment when the capacity of an individual vessel or system is greater than 1.3 gallons or the capacity of multiple vessels or systems is greater than 5.3 gallons. (5005.2.1.4) Storage of Class 2 Oxidizers. Storage of Class 2 oxidizers such as Calcium Hypochlorite (50% or less by weight) and Bromine shall be limited to no more than 250 pounds in any control area within a building not protected with an automatic sprinkler system. This may be increased to no more than 500 pounds where an automatic sprinkler system is provided. (5003.1.1) Release of Hazardous Materials Prohibited. Hazardous materials in any quantity shall not be released into a sewer, storm drain, ditch, drainage canal, creek, stream, river, lake or tidal waterway or on the ground, sidewalk, street, highway or into the atmosphere. (5003.3) POOL OPERATORS & LIFE GUARDS Hazardous Materials Familiarization & Training Requirements. Persons responsible for the operation of areas in which hazardous materials are stored, dispensed, handled or used shall: 1. Be familiar with the chemical nature of the materials and the appropriate mitigating actions necessary in the event of a fire, leak or spill. (407.4, 5003.9.1) 2. Be trained to liaison with the fire department which includes preplanning emergency responses and identification of the locations of hazardous materials. (407.4, 5003.9.1.1) 3. Have access to Material Safety Data Sheets (MSDS). (407.4, 5003.4) 4. Be knowledgeable in the on-site emergency response procedures. (407.4, 5003.9.1.1) Notification of Emergency Responders (Call 911). In accordance with sections 401.3 and 5003.3.1 of the Fire Prevention Code, notification of emergency responders shall be as follows: 1. Fire Events & Alarm Activations. In the event an unwanted fire occurs on a property or upon activation of a fire alarm signal, pool operators and/or life guards shall immediately notify the fire department by calling 911. 2. Hazardous Materials Release. Any person who witnesses, discovers, or otherwise has knowledge of a spill, leak or other release of a hazardous material or other material that may negatively impact the environment, regardless of quantity, shall immediately report such spill, leak or release to the Department of Public Safety Communications (Call 911) and to the Office of the Fire Marshal by calling 703-246-4386 (Leave a Message). To learn more about hazardous materials discharge/spill notification procedures, visit the Fairfax Joint Local Emergency Planning Committee (FJLEPC) online at: www.lepcfairfax.org Emergency Procedures. Pool operators and life guards shall be able to reasonably articulate the following procedures related to the release or spill of hazardous pool chemicals: 1. Evacuate the pool, pool deck, and pool house. Direct persons to a safe area. 2. Immediately Call 911 to notify emergency responders of the situation. 3 of 5

3. Retrieve MSDS (safely) and move to a safe area with MSDS in hand. 4. Administer first aid as appropriate. Consult MSDS for chemical-related first aid information. 5. Meet emergency responders with MSDS and explain the nature of the emergency. FIRE SAFETY REQUIREMENTS Emergency Exits & Pool Access Gates. Required exit accesses, exits or exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency when the areas served by such exits are occupied. In addition, gates serving the pool area shall be available for use by pool staff in case of emergency. Pool staff shall be able to unlock all gates in the presence of the fire official. (1030.2, 503.9, 506.1.1) Portable Fire Extinguisher(s). A portable fire extinguisher with a minimum rating of 2-A shall be conspicuously mounted within a travel distance of 75 feet for occupancies that involve primarily Class A fire hazards. Extinguishers with a Class C rating shall be required where energized electrical equipment can be encountered. Only water-type extinguishers shall be installed in areas containing oxidizers such as Calcium Hypochlorite, Trichloroisocyanuric Acid, and Bromine. Multipurpose dry chemical fire extinguishers shall not be installed in areas containing oxidizers. (906.1, 906.3, NFPA 10, 5.5.7) Fire Extinguisher Maintenance. Extinguishers shall be readily accessible and immediately available for use and not obstructed or obscured from view. Extinguishers less than 40 pounds shall be installed so that their tops are not more than 5 feet above the floor. Extinguishers shall be inspected and maintained in accordance with NFPA 10 and have a current inspection tag indicating maintenance within the past 12 months. (906.5, 906.6, 906.9.2, 906.2) Fueled Equipment Storage Prohibited Inside. Fueled equipment including, but not limited to, motorcycles, mopeds, lawn-care equipment, portable generators and portable cooking equipment, shall not be stored, operated or repaired within a building including pool chemical dispensing and storage areas. (313.1.1) Combustible Material Storage in Buildings. Combustible material, including LPG, shall not be stored in boiler rooms, mechanical rooms or electrical equipment rooms. Where permitted, storage of combustible materials in buildings shall be orderly. Storage shall be separated from heaters or heating devices by distance or shielding so that ignition cannot occur. (315.3, 315.3.3) Waste Accumulation Prohibited. Combustible waste material creating a fire hazard shall not be allowed to accumulate in buildings or structures or upon premises. (304.1) Electrical Hazards and Open Circuits/Junctions Prohibited. Identified electrical hazards shall be abated. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes an electrical shock or fire hazard shall not be used. Open junction boxes and open-wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. (605.1, 605.6) Electrical Equipment Areas. A working space of not less than 30 inches in width, 36 inches in depth and 78 inches in height shall be provided in front of electrical service equipment. Where the electrical service equipment is wider than 30 inches, the working space shall not be less than the width of the equipment. No storage of any materials shall be located within the designated working space. Illumination shall be provided for service equipment areas, motor control centers and electrical panelboards (pump rooms). (605.2 & 605.3) 4 of 5

Fairfax County is committed to nondiscrimination on the basis of disability in all county programs, services and activities. Reasonable accommodations will be provided upon request. Materials such as this publication may be available in alternate formats. To request reasonable ADA accommodations or materials in alternative formats, call the Office of the Fire Marshal at 703-246-4803 (TTY: 711 or 1-800-828-1120) or write us at the following address: 10700 Page Avenue, Fairfax, VA 22030 5 of 5