INSTRUCTION MANUAL DATA EXTRACTION PROCEDURE MODEL VR-3000/VR-3000S DO NOT OPEN. Important material for the exclusive use by Investigating Authorities



Similar documents
Additional Requirements for ARES-G2 / RSA-G2. One Ethernet 10 Base T/100 Base TX network card required for communication with the instrument.

BASLER ACE QUICK INSTALLATION GUIDE

Ultra Thin Client TC-401 TC-402. Users s Guide

SOFTWARE INSTALLATION AND USB/i.LINK CONNECTION GUIDE

JKW-IP. IP Video Entry System. QuikStart Guide

3.5 EXTERNAL NETWORK HDD. User s Manual

EasyMP Multi PC Projection Operation Guide

Preparing the Windows version of the software for use

Receptionist-Small Business Administrator guide

SATO Network Interface Card Configuration Instructions

Single-bay NAS Server

Creating client-server setup with multiple clients

Wrist Audio Player Link Soft for Macintosh. User s Guide

64-Bit Compatibility with Micromeritics Applications

Central Management System

MC Remote Control Software MCTerminal Operation Manual

VISION DX 600 Series

AW-HE60 Firmware Upgrade Procedure

CX Series. Video Recording Server. Quick Start Guide CX784 / CX788 / CX7816. Version

SOP085 - HELLER OVEN SOFTWARE INSTALLATION PROCEDURE. For version 6.2.x.x

Internet Guide. Prepared for 55 John Street

Taurus Super-S3 LCM. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.2

Quick Start Guide GigE Vision Single-Head Controller

USB-MIDI Setup Guide. Operating requirements

Upgrading from Call Center Reporting to Reporting for Call Center

Movie Cube. User s Guide to Wireless Function

Iridium Extreme TM Satellite Phone. Data Services Manual

4 Networking Generators

Taurus - RAID. Dual-Bay Storage Enclosure for 3.5 Serial ATA Hard Drives. User Manual

1. Hardware Installation

SQL Server 2008 R2 Express Installation for Windows 7 Professional, Vista Business Edition and XP Professional.

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

Multi-Profile CMOS Infrared Network Camera

Caplio Utility for Windows

V.I.P. Kit. Video Insight Pilot Kit. (Video Insight Pilot Kit).

Figure 1 Sample WiseLink screens, showing MP3 music files (left) and photos (right) available as shared files from your networked PC or media server

E-Mon Communication Gateway Utility Instructions for BACnet/mstp

Juniper NetScreen IPSec Dial Client. Installation Guide for Windows 2000 Windows XP Windows Vista

Internet for Everyone In-Room Instructions January 2011 Version 1.3

INSTALLATION GUIDE. AXIS Camera Station

OPERATION MANUAL. ValueJet Print Server. Read This Manual Before Using The Application VPSE-C-01. 管 理 No.

3M Occupational Health and Environmental Safety 3M E-A-Rfit Validation System. Version 4.2 Software Installation Guide (Upgrade) 1 P age

DATA PROJECTOR XJ-A146/XJ-A246/XJ-A256

Special Note Ethernet Connection Problems and Handling Methods (CS203 / CS468 / CS469)

Preface Version 1.0 (1808. rev. 2)

DATA PROJECTOR XJ-A135/XJ-A145/XJ-A235/ XJ-A245

Hydra Super-S Combo. 4-Bay RAID Storage Enclosure (3.5 SATA HDD) User Manual July 29, v1.3

DRO-210i LOAD BALANCING ROUTER. Review Package Contents

Operating Instructions

Application Note: Connecting to a 2500 Series Processor using PLC Workshop

COBRA 18R2 Wired Reprogramming Instructions

LPT1 Printer Connector. External Power Supply Connector Power Indicator

Acer LCD Monitor Driver Installation Guide

Recommended Network Setup

EasyMP Network Projection Operation Guide

SOFTWARE INSTALLATION AND USB CONNECTION GUIDE

Topaz Installation Sheet

Interfacing Basler GigE Cameras With Cognex VisionPro 7.2

USB Driver Installation Manual [Windows Vista/Windows 7]

USB DRIVER INSTALLATION GUIDE

c. Securely insert the Ethernet cable from your cable or DSL modem into the Internet port (B) on the WGT634U. Broadband modem

Migrating MSDE to Microsoft SQL 2008 R2 Express

e-dpp May 2013 Quick Installation Guide Microsoft Windows 2003 Server, XP, Vista, 7 Access Database

AXIS Camera Station Quick Installation Guide

Operating Instructions

Back Office Recorder Dig04 Installation Guide

Phone: Fax: Web: info@ctiautomation.net

EasyMP Network Projection Operation Guide

Installation Guide. N5101A Baseband Studio PCI Card. Overview

Enterprise Manager. Version 6.2. Installation Guide

Digital Photo Bank / Portable HDD Pan Ocean E350 User Manual

DSL Self-install Kit Instructions. SpeedStream 4100

WD Sentinel DX4000. Small Office Storage Server. Administrator s Quick Install Guide

NTL Studio SQL Database Installation & Configuration

USB DRIVER INSTALLATION GUIDE

Windows Vista /Windows 7 Installation Guide

LPR for Windows 95/98/Me/2000/XP TCP/IP Printing User s Guide. Rev. 03 (November, 2001)

USB 2.0 VGA ADAPTER USER MANUAL

Guide to Installing BBL Crystal MIND on Windows 7

Server Application. ACTi NVR v2.2. Quick Installation Guide

Configuring the WT-4 for ftp (Ad-hoc Mode)

Chapter 1 Downloading Images to Your Computer (Windows)

Allworx OfficeSafe Operations Guide Release 6.0

1. Central Monitoring System Software

USB DRIVER INSTALLATION GUIDE

OfficeServ Link. User Guide. Version 2.1 June 2005

TDP43ME NetPS. Network Printer Server. Control Center. for Ethernet Module

Backup/Restore application

Magaya Software Installation Guide

FortiVoice. Version 7.00 Start Guide

Preface. System configuration diagram

Installing USB Drivers With Microsoft Windows XP

The Evolved Office APPLICATION PLATFORM REQUIREMENTS. Release: 16.0

Point of Sale 2015 Enterprise. Installation Guide

XTreme Files OS & Data Backup/Restore User Manual Please read the Instruction manual before using the XTreme Files (F Series) 1.

Network Setup Guide. Introduction. Setting up for use over LAN

RSM Web Gateway RSM Web Client INSTALLATION AND ADMINISTRATION GUIDE

1. Central Monitoring System Software

Quick Start Guide. GV-Redundant Server GV-Failover Server. 1 Introduction. Packing List

PU-USBX. USB over Ethernet Extender OPERATION MANUAL

Transcription:

INSTRUCTION MANUAL DATA EXTRACTION PROCEDURE MODEL VR-3000/VR-3000S DO NOT OPEN Important material for the exclusive use by Investigating Authorities All brand and product names are trademarks, registered trademarks or service marks of their respective holders. www.furuno.com

Record of Pub Rev., Prog. No. Revision No., Program No.(software) Reason for revision Date of Revision A, Apr. 19, 2006 VR-3000 SYSTEM 2450031-01, RAP 2450026-01 1 st production printing. B, July 17, 2008 VR-3000 SYSTEM 2450031-02, RAP 2450026-01 For new standard. C, Dec. 19, 2008 Same as above Added section 6 & 7. D, June 29, 2010 Same as above Changed procedure on pages 4, 5 E, Apr. 30, 2011 Same as above Added descriptions for Windows 7 Parts and equipment needed PC (OS: Windows XP SP2/Vista (32 bit version)/7 (32 bit version), I/F: IEEE1394 x1, Ethernet x1, Memory: minimum 512 MB recommended 1GB for XP or minimum 1 GB for Vista, HDD: minimum 10GB, Software: Internet Explorer 6.0 or higher, DirectX 9.0c or higher, JAVA VM1.6 or higher (VM6.21 for Windows 7) IEEE 1394 cable (4P-6P) Mandatory for connecting PC directly to DRU and HDD. Ethernet cross cable 1. How to Set the PC Set the IP address and subnet mask on the PC as below. The IP address of VR-3000 is 10.0.0.100. Windows XP 1. Click Start, Settings, Control Panel and Network and Dial-up Connections. 2. Click Local Area Network, General, Properties and Internet Protocol (TCP/IP). 3. Click the Properties button. 4. Select "Use the following address". 5. Enter IP address and subnet mask: IP address: 10.0.0.102 or 10.0.0.99 (other than 10.0.0.100) Subnet mask: 255.0.0Ck.0 6. Click the OK button and then click it again on the next screen. 7. Restart the PC. Windows Vista 1. Click Start, Control Panel, Network and Internet, Network and Sharing Center. 2. Click View status to show the Local Area Connection Status dialog box. 3. Click the Properties button. 4. Click the Continue button. 5. Select Internet Protocol Version 4 (TCP/IP v4). 6. Click the Properties button. 7. Select "Use the following IP address". 8. Enter IP address and subnet mask: IP address: 10.0.0.102 or 10.0.0.99 (other than 10.0.0.100) Subnet mask: 255.0.0.0 9. Click the OK button and then click it again on the next screen. 10. Restart the PC. 2

Windows 7 1. Click Start, Control Panel, Network and Internet, Network and Sharing Center. 2. Click the Properties button on the Local Area Connection Status dialog box. 3. Select Internet Protocol Version 4 (TCP/IP v4) then click the Properties button. 4. Click the Use the following IP address button. 5. Enter IP address and subnet mask: IP address: 10.0.0.102 or 10.0.0.99 (other than 10.0.0.100) Subnet mask: 255.0.0.0 6. Click the OK button and then click the Close button. 7. Restart the PC. 2. How to Download the Live Player Software If the OS of your PC is Windows 7, first temporarily deactivate the firewall by following the procedure below. Otherwise, go to "How to download the Live Player software". Deactivate firewall (Windows 7) Temporarily deactivate the Windows firewall as follows to download the Live Player software. 1. Click the Start button then open the Control Panel. 2. Select Network and Internet. 3. Select Network and Sharing Center. 4. Select Windows Firewall from the left window. 5. Select Turn Windows Firewall on or off from the left window. 6. At Public network location settings, select Turn off Windows Firewall (not recommended) then click the OK button. If you try to install the Live Player with the firewall active, the following occurs: VDR settings cannot be downloaded with "live" Live Player connection. Block data cannot be obtained via FTP (to replay data) when the Backup HDD is connected to LAN. Data extraction and analysis also are not possible. How to download the Live Player software 1. Connect a PC to DCU (Data Collecting Unit) as shown below. 2. Open Internet Explorer. 3. Enter ftp://10.0.0.100/pub/ in the address box. 4. Click the View.exe file on the PC then click the Save button. 5. Select the directory to save the software then click the Save button. DCU PC J14 (DATA) LAN cable Figure 1 3

3. How to Install the Player Software This procedure is applicable to both Windows XP and Windows 7. Necessary software Install the following software if they have not been installed already. Java VM 1.6, update 21 (Windows XP), or Java VM 6.21 (Windows 7). Install only if audio and video cannot be played back properly. Direct X9.0c (or higher) (Direct X comes preinstalled in Windows XP2/Windows Vista/Windows 7. (Version can be checked by running C:\WINDOWS\system32\dxdiag.exe.) Microsoft VC++ runtime. (Microsoft VC++ runtime comes preinstalled in Windows XP2/Windows Vista/Windows 7.) Setup for Windows 7 Run the Live Player 4 as an administrator in order to install the program. 1. Click the Start button, select All Programs and check that VR-3000 appears. 2. Select LivePlayerV4 at VR-3000, right click, then select Properties. 3. Select Compatibility from the Live Player V4 Properties dialog box. 4. At Privilege Level, check Run this program as an administrator. How to install the Live Player software 1. Double click View.exe. 2. The Setup VR-3000 dialog box appears; click the Next button. 3. Confirm that the install location is C:\Program Files then click the Next button. 4. The Folder Exists dialog box appears; click the Yes button. 5. After the Folder Exists dialog box disappears, click the Next and Install buttons. 6. After the installation is completed, check that the message "Yes, restart computer now" is checked then click the Finish button. 4. How to Extract Data Backup HDD LAN connection Data can be extracted from J14 (DATA) port during recording from an area other than a recording area. 1. Connect the PC to the DCU as shown in figure 1. 2. Start the Live Player V4. 3. Open the Tool menu and select Source Select. Select Backup from the pull-down menu. 4. Check LAN then click the Analyze Area button. Check that the IP address is 10.0.0.100. After a while, recording status of four areas is displayed. 5. Select the area to extract then click the Analyze Track button. 6. Click the Connect button. 7. Select Extract from the Tool menu to show the Extraction dialog box. 8. Select the track to extract. 9. Click the Select button and select the location where to save data. 10. Click the Start button. 4

11. After the extraction is completed, click the buttons OK, Close and Close in that order. Disconnect the LAN cable from J14 port. Direct connection Data cannot be extracted during recording. 1. Start the Live Player V4. 2. Open the Tool menu and select Source Select. Select Live from the pull-down menu. 3. Click the Alarm tab and open Alarm History. 4. Set the Playback/CPU slide switch in the DCU to the Playback position. 5. Wait approx 10 minutes and confirm that the Alert 174 occurs on Alarm History of Live Player V4. 6. Connect the PC to the DCU as shown in figure 2. Disconnect J8 from the DCU (cable connector coming from the DRU). 7. Open the Tool menu and select Source Select. Select Backup from the pull-down menu. 8. Check Direct then click the Analyze Area button. 9. Select the area to extract then click the Analyze Track button. 10. Click the Connect button. 11. Select Extract from the Tool menu to show the Extraction dialog box. 12. Select the track to extract. 13. Click the Select button and select the location where to save data. 14. Click the Start button. 15. After the extraction is completed, click OK, Close and Close in that order. Then, do the following. a) Disconnect the cable between the PC and J6 in the DCU. b) Connect cable between J8 in the DCU and the DRU. c) Set the Playback/CPU slide switch in the DCU to the CPU position. DCU Set Playback/CPU slide SW to Playback. Backup HDD* 1 * 1: Disconnect when DRU Connection. J8(DRU)* 2 * 2: Disconnect when Direct Conncton. DRU PC J6(Playback) Figure 2 IEEE1394 cable 5

DRU Refer to the Operator's Manual for the Live Player V4. Data cannot be extracted during recording. 1. Start the Live Player V4. 2. Open the Tool menu and select Source Select. Select Live from the pull-down menu. 3. Click the Alarm tab and open Alarm History. 4. Set the Playback/CPU slide switch in the DCU to the Playback position. 5. Wait approx. 10 minutes and confirm that the Alert 174 occurs on Alarm History of Live Player V4. 6. Connect the PC to the DCU as shown in Figure 2. Disconnect the cable attached to the Backup HDD. 7. Open the Tool menu and select Source Select. Select DRU from the pull-down menu. 8. Click the Analyze Track button. 9. Click the Connect button. 10. Select Extract from the Tool menu to show the Extraction dialog box. 11. Select the track to extract. 12. Click the Select button and select the location where to save data. 13. Click the Start button. 14. After the extraction is completed, click OK, Close and Close in that order. Then, do the following. a) Disconnect the cable between the PC and J6 in the DCU. b) Connect the Backup HDD as original. c) Set the Playback/CPU slide switch in the DCU to the CPU position. 5. How to Play Back Data Refer to Operator s Manual of the Live Player V4. 1. Select Source Select from the Tool menu. 2. Select Extract from the pull-down menu. 3. Click the Select button and select the file to play back. 4. Click the Analyze Track button. 5. Click the Connect button. 6. Click the Start Play button to play back data. 6

6. How to Retrieve flash disk assembly from the DRU A) In case of non-fire incident 1. Open the cover of the DRU as follows. a) Stand the DRU so that the acoustic beacon is down. Reflection tape Acoustic beacon (lower part) b) Remove the reflection tape from the upper part of the DRU as shown in the figure below. Cover Socket head screw (8 pcs) c) Remove eight socket head screws by using a hex. wrench (5 mm). d) Remove the cover from the body, by striking the four projections softly and alternately with a plastic-head hammer. e) Cut the cable between the cover and the body. Cut the cable. Cover 7

2. Remove the inner capsule as follows. a) Remove the thermal insulator 1. Thermal insulator 1 b) Cut away the thermal insulator 2 with a box cutter and pull out the inner capsule (enclosed in plaster). Thermal insulator 2 Inner capsule (enclosed in plaster) Thermal insulator 2 Inner capsule (enclosed in plaster) 8

c) Cut the plaster at an angle with a saw as shown in the figure below. d) Break up the plaster with a slotted-head screwdriver as shown in the figure below. 3. Remove the flash disk assembly as follows. a) Use a box cutter to remove the silicone to expose two holes as shown below. Hole Remove silicone with a box cutter to expose two holes. Hole Inner capsule b) Set the pin spanner to the holes and rotate the tool to separate the case of the inner capsule from the flash disk assembly. 9

Pin spanner PW-100 (Produced by Super Tool Co. Ltd., Japan) Case of inner capsule Flash disk assembly c) Detach the connector plug and remove four screws. Remove four screws. Detach connector plug. d) Unfasten four screws to remove the circular printed circuit board. Remove circular pcb. e) Unfasten four screws to remove the plate. 10

Remove this plate. Flash disk assembly B) In case of fire incident 1. Stand the DRU so that the acoustic beacon is down. Connect IEEE cable here at Paragraph 7. Socket head screw (8 pcs) 2. Remove eight socket head screws by using a hex. wrench (5 mm). 3. Remove the top cover from the body, by striking the four projections softly and alternately with a plastic-head hammer. 4. If the cable between the top cover and the body is connected, cut it. 11

Top cover 5. Remove the thermal insulator. Thermal insulator 6. Set the DRU upside down and remove the content (plaster pot with thermal insulator) from the DRU body. 7. Remove the thermal insulator to access the plaster pot. 12

Thermal insulator Plaster pot (thermal insulator removed) 8. Cut the plaster at an angle with a saw as shown in the figure on page 9. 9. Break up the plaster with a slotted-head screwdriver. 10. Remove the flash disk assembly as described in step 3 on page 9. 7. Retrieve data from the flash disk assembly 1. Connect the flash disk assembly and PC as shown in the figure below. Flash disk Assembly IEEE1394 Repeater IEEE1394 cable (6P-6P) AC adaptor 12-30 VDC more than 1.2A IEEE1394 cable (4P-6P) 100-240 VAC 2. Start the Live Player V4 software at the PC. 3. Open the Tool menu and select Source Select. Select Backup from the pull-down menu. 4. Select Direct for IEEE1394 cable connection. 5. Click the Connect button in the Source Select dialog box. After completion of connection with the flash disk assembly, the Source Select dialog box disappears. 6. Click the Start button to display the data recorded in the flash disk. The data appears in the data window. 7. To stop displaying the data, click the Stop button. 13

PUB. NO. C42-00408-F (1111, REFU) VR-3000/3000S