PXM20-E. Operator unit DESIGO PX



Similar documents
Digital input modules

TX OPEN RS232/485 module

Automation stations modular model

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

PCS0100en Persy Control Services B.V. Netherlands

RRV934. Multi-controller. Synco living

DESIGO PX PXM10 operator unit User's guide Version 2.3. Siemens Building Technologies Building Automation

HCR3.2/.. Chipcard reader HOTEL SOLUTION

For UK only RXL39.1 and the applications package SP-03 are sold in the United Kingdom only.

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

IntesisBox KNX LG Air Conditioning

IntesisBox Modbus Server SAMSUNG Air Conditioners

KNX Panasonic Air Conditioners

Energy Communication Unit (ECU)

IFS SP-PoE Splitter User Manual

Energy Communication Unit (ECU)

Automation stations modular series

ISIO 200. Binary Input/Output (I/O) Terminal with IEC Interface

VFS24/32HDIP. Public Display IP Monitor User Manual

OZW V2.0. Web server. Synco TM, Synco TM living

AXIS T81B22 DC 30W Midspan

IntesisBox KNX Mitsubishi Heavy Industries AC

Modbus Server SAMSUNG Air Conditioners

OZS Web server. For LPB/BSB plants

VTO6xxx. IP door stations. User manual

I STAR COMPUTER CO., LTD

HWg-STE HWg-STE PoE MANUAL

How To Use An Ip Phone With A Sim Sim Sims 2 (Iphone) Or Ip Phone (Ip Phone) With A Microsoft Ip Phone 2 (Ipphone) With An Ipro (Ipro) Or Sims 1 (Ip

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Quick Connect. quick - simple - efficient.

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

1 Serial RS232 to Ethernet Adapter Installation Guide

IntesisBox KNX Modbus TCP master

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

USER MANUAL. PingBrother EPIW104 managed passive poe switch & IP watchdog

Product and functional description

Indoor / Outdoor Antenna

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Product Information Sheet UH36 Hi Pot Tester

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

Peak Atlas IT. RJ45 Network Cable Analyser Model UTP05. Designed and manufactured with pride in the UK. User Guide

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

Setup guide. point to point wall plate extenders

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

BACnet router for BACnet/IP BACnet/LonTalk BACnet MS/TP

MultiViu Flex 7 Data Sheet

IntesisBox. KNX SAMSUNG Air Conditioning. Gateway for integration of Samsung air conditioners into KNX control systems. RS485.

Heating Controller. Building Technologies HVAC Products

Connect to a remote PC via Ethernet with a monitor, keyboard, and mouse. This network monitor offers both long distance and wireless transmission.

Air damper actuators

HMI display Installation Guide

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

OPTICAL HEADEND PLATFORM OTOHP-NMS NETWORK MONITORING MODULE INSTRUCTION MANUAL

SPL 2-00/-01 OPERATION INSTRUCTIONS

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Cisco Unified IP Conference Phone 8831 Installation

User Manual. EtherUSB

Cisco Unified IP Phone Power Injector

II Intelligent PC/CAN Interface. Manual

Index. ROPIX P18 Hardware ROPIX P18 Software ROPIX P18

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

GSM HOME SECURITY SYSTEM

Electronic Control Devices The European Product Catalogue 2007

UniOP epad33 and epad33t

Foxboro Evo Process Automation System

Uninterruptible Power Supply

Users manual. TCW181B-CM_R1 Page 1

HERZ-Thermal Actuators

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address

DTS/DRS-1000RV. Owner s Manual. DTS-1000RV: DVI/HDMI or VGA, Audio, RS-232C Transmitter Extender

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

Drayton Digistat +2RF/+3RF

FIREDEX Conventional Fire Panels

Product Manual. ABB i-bus KNX IP Interface IPS/S 2.1. Intelligent Installation Systems ABB

Transmitter Actuator 230V wave UP 560. Operation

Process Alarm Solutions

PCS300 Universal IP Reporting Module V1.0

Operating Instructions. Sophos Access Points

Setting Up the Cisco Unified IP Phone

VAV compact controller KNX / PL-Link

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Power Meter Series 700

Duct Humidity Transmitter

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

OZW30. Central Unit SYNERGYR

IntesisBox KNX Modbus RTU master

Operating instructions. AS-i Profibus gateway AC1411 / AC /00 04/2014

R60 USB to CAN interface Manual (1.5 EN)

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

3.5 EXTERNAL NETWORK HDD. User s Manual

TrueAlarm Fire Alarm Systems

AC-115 Compact Networked Single Door Controller. Installation and User Manual

VAV compact controller KNX / PL-Link

Multifunction devices

Transcription:

9 234 DESIGO PX Operator unit PXM20-E Network-compatible operator unit for viewing and operating one or more DESIGO PX automation stations. High-grade display with adjustable contrast Simple key operation with direct access to the required plant information Generic operation and display of plant functions (alarm handling, time schedulers, calendars, setpoint adjustments, display of current values, etc.) Integrated acoustic and/or visual collective alarm Graphic online-trend function Support of integrated access protection in the overall DESIGO system Facility to add or delete new users Automatic logout Heating curve graphics System date and time setting Wiring test for IOs Context-sensitive help function Installation in modular automation station PXC..-U or remote 10/100 Mbps RJ45 Ethernet connection with built-in autosensing Supports POE (Power Over Ethernet) operating voltage to IEE 802.3af CM1N9234en_02 18 May 2009 Building Technologies

Application The PXM20-E operator unit ensures the convenient display and operation of DESIGO PX automation stations via BACnet network communication. The graphics-based display with clear text and direct access via the keyboard ensure a most user-friendly operation. Functions All values visible in the system can be displayed in accordance with the defined operator profile. Typical displays: Display of current values Setpoint and parameter settings Maintenance and error messages Alarm lists and single alarm messages with acknowledgement option and/or reset Time schedulers (7-day schedules and exception programs) Plant switching Login and password inputs An integrated collective alarm message system with acoustic and visual indication is provided. Operating concept User's guide As the PXM20-E operator unit is designed for end-user operation the operating concept concentrates on the simplest and clearest possible display following intuitive operating principles rather then displaying as many values as possible. Any text is displayed as clear text in the chosen language. To ensure a clear orientation for any operator the two top display lines (header lines) always show which building services system or which function is currently in operation. The basic concept of the operation ensures that it is always possible to select direct, with the click of a button on the keyboard, the plant information shown on the relevant line (direct access keys). Any settings or modifications (for example in graphics) can be followed direct on the display (e.g. graphics display for scheduler). The basic concept also ensures that all information and help functions can be called up any time (info key). The functions of the PXM20-E are described in detail in the User's guide, DESIGO V2.35, PXM20/PXM20-E operator unit, document CM110754. Indicators and operator controls 1 2 00262 3 4 OK ESC? + PXM20 7 5 6 2/8

1. Display 2. Navigation keys (direct access keys and PageUp/PageDown keys): The direct access keys allow direct access to the relevant line. Possible functions: Select value and start the value adjustment Confirm new value Start function Open item 3. Alarm LED: The alarm LED lights up or flashes if an alarm is present in the system. 4. The PageUp and PageDown keys are provided for page scrolling if a page contains more values than can be shown on the display at the same time. 5. Edit keys: These keys allow the selected values to be modified (<+> and < >) and confirmed (< >). 6. ESC key (Undo and GoUp): When editing a value the editing process can be cancelled by using the Undo key (previous value will be displayed again). Otherwise the GoUp key selects the hierarchically higher object. This key is placed between the two blocks containing the navigation and editing keys because, according to its function, it belongs to both. 7. <?> Info key: This key selects the information mode for the next keyboard click. Generic operation and display Depending on to the application program each menu tree is different. Navigation through the menu tree is based on the "ClickDown" procedure using the navigation keys. Alarms and events If the PXM20-E receives an alarm or an event appears on the display a pop-op window appears with the relevant information. Visual and acoustic alarm When an alarm is present the alarm LED flashes and changes to steady light when all alarms have been acknowledged. The acoustic alarm is provided as an option and can be activated optionally when an alarm is triggered. Alarm Viewer Alarms are written into the Alarm Viewer with a symbol, a description and a time/date stamp in chronological order. An acknowledgement mask to acknowledge alarms can be called up in the Alarm Viewer. After acknowledgement the alarm entry disappears from the Alarm Viewer ; however, it will continue to be saved in the history list. Further details can be viewed in the alarm history (e.g. out of service, overridden, dead band, present value, etc.) The PXM20-E history can contain max. 50 entries; the older ones are deleted. Scheduler The Scheduler allows the user a time-dependent switch on/off and the programming of time-dependent setpoint adjustments. The Scheduler consists of a 7-day schedule and an exception program. 7-day schedule With the help of the navigation and editing keys it is very simple to create, modify, delete or copy a 7-day schedule in this mask. For each day an individual "road map" is programmed. Exception programs If the field EXCEPTION OVERVIEW is clicked in the 7-day schedule (see above) the current monthly overview appears and shows as inverted all the days which are affected by an exception. All other months can be called up as overview by using the top direct access key. 3/8

In the exception program, too, the exceptions are created, modified or deleted by using the navigation and editing keys. It is possible to define exception days (e.g. a bank holiday) as well as exception periods (e.g. holiday periods). Click the EXCEPTIONS field to display a list of all programmed exceptions. Online trend The PXM20-E operator unit provides the user with five channels for trend logging, enabling 5 data points to be logged. There are three separate ways of viewing the trend data: Graphical view: In this view all the values of a trend data point stored in PXM20-E will be displayed graphically Online graphical view: In the online view the values will be displayed in a graphical and dynamic manner, i.e. in real time. List: In place of a graphic view, the values can be displayed in list form Info concept Access protection Auto logout and sleep mode Language versions Press the info key to switch to info mode. In this info mode two different kinds of information can be called up: Pressing the info key a second time displays general information for the currently displayed object (e.g. complete path, clear text of object). Pressing a direct access key in info mode displays information for the object or value on the selected line. Exit the info mode by pressing any key. Login by entering password with string editor Display and operation in accordance with user privileges Definition of user privileges during engineering of DESIGO PX configurations Login always referenced to a site Wiring test possible without login Alarms Alarm display depends on user privilege Alarm handling in accordance with user privileges Logout If no operator activities are carried out within a set period the device switches off automatically and the display is turned off. Pressing any key activates the device automatically again and the background lighting of the display is switched on. When the operator unit is delivered the language is set to English. The language setting can be changed internally. 4/8

Ordering 1 PXM20-E operator unit Compatibility Device Type Data sheet Modular automation stations PXC...-U 9221 Compact automation stations PXC...E-D N9215 Modular automation stations PXC...E-D N9222 Accessories Description Connection cable, length 3.0 m (order separately) Adapter cablers232 RJ45 to connect a PXA-C1 to a PC (order separately) Adapter on PXM20-E for firmware download (order separately) Mounting frame for mounting on the wall or on the control panel door (order separately) Type PXA-C1 PXA-C2 PXA-C4 PXA-H1 Design The PXM20-E operator unit is contained in a robust plastic housing, ideally suited for its many different mounting methods. All indicators and controls are mounted on the front cover of the unit (see page 2). The connections for the automation stations are incorporated on the back of the unit (see page 7). Mounting instructions The PXM20-E is suitable for control panel front mounting or vertical panels (e.g. remote operating panels or similar units). The unit is also suitable for DIN rail snap-mounting. In addition, the PXM20-E can be mounted direct on any modular automation station. The required Ethernet network connection is an anti-kink cable which can be introduced through an aperture in the modular automation station. Commissioning Wiring test Switchless commissioning Firmware download When using network-compatible PXM20-E units it is possible to carry out a wiring test of the connected field devices even without a loaded application program. The field devices are shown with the current value and unit. Commissioning before programming: The wiring test supports the reading of all I/Os of compact automation stations, and modular as long as the modules have an address key. In addition the wiring test supports writing to all outputs. This means you can switch on fans, pumps, lamps etc., or drive valves to a defined position. The outputs keep their state as long as the automation station is powered. It is possible to download firmware via FTP. 5/8

Disposal The device is classified as waste electronic equipment in terms of the European Directive 2002/96/EC (WEEE) and should not be disposed of as unsorted municipal waste. The relevant national legal rules are to be adhered to. Regarding disposal, use the systems setup for collecting electronic waste. Observe all local and applicable laws. Technical data General device data Operating voltage for 2-pin connector AC 24 V ± 20 % or DC min. 12 V... max. 40 V Operating voltage when plugged into modular automation station AC 24 V ± 20 %, derived automatically from modular automation station Electrical voltage via Ethernet connection Power Over Ethernet (POE) to IEEE 802.3af Safety extra low voltage SELV Protective extra low voltage PELV HD 384 Frequency 50/60 Hz Power consumption AC 24 V max. 9 VA DC 12... 40 V max. 5 W Internal fuse Thermal, self-resetting Operating data Main processor Freescale PowerPC Data backup in case of power failure Applications, parameter (FLASH) > 10 years Keyboard Type Keyboard with plastic membrane and pressure point Key area 7 x 7 mm Switching pressure 2.1 N Travel 0.6... 0.7 mm Operating life > 1 million operations Material, front membrane Polycarbonate Material, contacts Conductive silver, snap-on discs gold-plated Display Mechanical LCD display F-STN, Black & White Display area 123 x 68 mm No. of dots 240 x 128 dots Dot size 0.47 x 0.47 mm Dot area 0.50 x 0.50 mm Optical Contrast ratio 20: 1 Brightness 60.0 cd/m 2 Viewing angle ± 40 Viewing direction 6 o'clock Background lighting CCFL (cold cathode fluorescent lamp) Rise time lamp 5 min = 80 % brightness Life time lamp 20,000 operating hours = 64 % brightness 6/8

Ethernet interface Network 10Base-T/100Base-TX, with built-in auto-sensing Cable Min. Cat 5, shielded if >3m PHY Auto-MDI/MDIX crossover correction Power supply via Ethernet connection Supports POE (Power Over Ethernet) to IEE 802.3af Green LED Ethernet Link OK Orange LED Ethernet Signal TX Protocol BACnet over IP Buzzer Noise level at 10 cm distance Min. 85dBA Frequency 2300 ± 300 Hz Mounting options For control panel mounting, remote operating panels, etc. DIN rail mounting Direct on modular automation stations Connections see page 7 Housing protection standard Protection standard to EN 60529 IP 40 (built-in), else IP 30 Protection class Insulation protection class III Ambient conditions Operation Class 3K5 to IEC 721 Temperature 0... 45 C Humidity < 85 % rh Transport Class 2K3 to IEC 721 Temperature 20... 60 C 1) Humidity < 85 % rh Industry standards Product safety Automatic electronic controls for household and similar use EN 60730-1 Special requirements for energy controllers EN 60730-2-11 Electromagnetic compatibility Interference immunity EN 61000-6-2 industrial Emitted interference EN 61000-6-3 residential Meets requirements for CE marking: Electromagnetic compatibility 2004/108/EC UL-Approbation UL 916: PAZX, PAZX7 Environmental compatibility The product environmental declaration CA1E9234 contains data on environmentally compatible product design and assessments (RoHS compliance, materials composition, packaging, environmental benefit, disposal) ISO 14001 (Environment) ISO 9001 (Quality) SN 36350 (Environmentally compatible products) 2002/95/EC (RoHS) Dimensions 117 x 210 x 37 mm (H x W x D) See Dimensions, page 7 1) Background color changes slightly depending on ambient temperature. This phenomenon is reversible. 7/8

Connections 00264 RJ45 socket for Ethernet connection 1 G0 (GND -) 2 G (Plus +) Pin1 I 2 Plug-in connection for modular automation stations PXC -U Dimensions All dimensions in mm 00342 00343 117 210 37 Drill and cut-out template 5.6 176.8 11.6 00267 47.4 ø 4.8 64.6 8/8 2005-2009 Siemens Switzerland Ltd. Subject to changes