ACOUSTIC ISOLATION DETAILS



Similar documents
ACOUSTIC ISOLATION DETAILS

Acoustical Design Guidelines for HVAC Systems in Schools

Case Studies Illustrating Acoustic Design Guidelines for HVAC Systems in Schools

Excerpts from the Canadian National Building Code (NBC)

All substantial design decisions and budget confirmation shall be resolved for the College to approve the Design Development Submittal.

LIFE SAFETY UPDATE. FULL SPRINKLERING OF ALL NURSING FACILITIES ADDITIONAL CLARIFICATIONS Prepared by Eric Rosenbaum, P.E. Hughes Associates, Inc.

SECTION TABLE OF CONTENTS. H Proposed Material, Product or Equipment Substitution Request

DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS

SPACE TYPE: LABORATORY (WET) FOR CHEMISTRY AND BIOLOGY

OPEN ITEMS LIST - CONSTRUCTION Project Name: East Central Middle School - Jackson County CLA#: 11003

CONSOLIDATED EDISON CO. OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY DISTRIBUTION ENGINEERING DEPARTMENT SUBSTATION & EQUIPMENT SECTION

Cooktop Low-Profile Ventilation Hoods

All work shall comply with applicable codes and ordinances. Work shall comply with the BOCA National Plumbing Code, latest edition.

SECTION GENERAL PROVISIONS FOR HVAC WORK

Gramercy Place Condo Association, Inc.

SPACE TYPE: AUTOMATED DATA PROCESSING CENTER (ADP) (MAINFRAME)

Facility Summary. Facility Condition Summary. Seattle School District David T. Denny International Infrastructure. Facility Components

HVAC INSTALLATION. Success with 2015 IECC Northeast & Mid-Atlantic. Checklist for Builders & Trades

Occupancy: Assembly (A-3) and Business -Includes offices, seminar rooms, classrooms, and café facility. Duke University Medical School

INSTALLING SEISMIC RESTRAINTS FOR MECHANICAL EQUIPMENT

RFQ # PR Replace Kitchen Equipment in the CGR

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

HVAC INSTALLATION SUCCESS WITH 2012 IECC DELAWARE. for Builders & Trades. Recommended Practices for Optimized Energy Savings

LITITZ MUTUAL INSURANCE COMPANY 2 North Broad Street Lititz, Pennsylvania - MAIN OFFICE -

Mark Cramer Inspection Services, Inc.

Electrical. This section applies to the design and installation of building power distribution systems.

Hamilton-Wentworth Catholic District School Board Event Listing By Ascending Event Year

FSD35, FSD36 AND FSD37 COMBINATION FIRE and SMOKE DAMPERS

MTA UNIVERSAL STATION PEDESTRIAN BRIDGE Los Angeles, CA. Project Manual and Specification 100% PE SUBMITTAL TABLE OF CONTENTS

DESIGN AND INSTALLATION OF RESIDENTIAL FLEXIBLE DUCTWORK SYSTEMS

MONTHLY PROJECT CONSTRUCTION PROGRESS REPORT #5

800 Communications Circuits

SECTION COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

City of Oviedo Commercial Shell Building Permit Application Guidelines

foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs.

FINAL December 2012 SECTION DUCTWORK

BUILDING ASSESSMENT QUESTIONNAIRE. B. TENANTS Is there more than one tenant in the building? YES

REVEWED BY: Ross Rogien B.O/P.R. ADDITIONAL REVIEW(S) REQ.-FIRE DEPT Y/N

Type 1 dryers: Domestic dryers to be used primarily in a family living environment. Residences Individual apartments or condominiums

ASX7-4-IOM-7 J

COMMERCIAL PLAN SUBMISSION FOR NEW CONSTRUCTION AND/OR RENOVATIONS

HV AC CODE CHECKLISTS

4 Installation Requirements

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit

Required Certification Documentation. Contractor's installation certification for range hood fire suppression systems.

OPTIMUS WORK CLASSIFICATION LIST ENTER ALL THAT APPLY

MRI RF SHIELDING DESIGN

EAST LYME HIGH SCHOOL

Pre-Drywall Inspection Report

SAMPLE SCHEDULE OF VALUES APPLICATION & CERTIFICATE FOR PAYMENT

SECTION MORTUARY REFRIGERATORS

Element D Services Heating, Ventilating, and Air Conditioning

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

State of Connecticut Department of Public Health RADON PROGRAM

Certification: Building Plans Examiner. Exam ID: B3

How To Repair A Boat Landing Deck With A Boat Bed

SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

Standards. 5 ANSI/TIA/EIA-569-A (CSA T530)

CITY OF FAIRFAX CODE ADMINISTRATION / FAX

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

Services Enclosures and Protected Shafts - Maintaining Compartmentation

HVAC Air Duct Leakage. Eli P. Howard, III Group Director Technical Resources SMACNA

ADDENDUM NO. 2 TO PROJECT NO

ENHANCED LABORATORY HVAC SYSTEM

VOLUME I PROCUREMENT AND CONTRACTING DOCUMENTS GROUP

TD AMERITRADE Park Omaha

Crawford Inspection Services C.C.B. #

PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS

Table of Contents. Division 2 Site Work Site Preparation Site Demolition Tree Protection Excavation, Trenching, and Backfilling for Utilities

Lightweight Partition Design for Residential and Commercial Buildings

Noise in the Classroom

Acoustic Design Guide. NR and NC Curves CIBSE Noise Ratings Environmental Noise Control Maximum Air Velocities in Ducts Privacy in Cellular Offices

SIMULATION PRE-INSTALLATION GUIDELINES CONTRACTOR REQUIREMENTS FOR ROOM PREPARATION

March 19, Ms. Jean McDonald CAP Management th Street, Suite 1010 Denver, Colorado 80202

Residential Deck Safety, Construction, and Repair

TIA 569 Standards Update Pathways & Spaces. Ignacio Diaz, RCDD April 25, 2012

Installation Instructions

SECTION A. Horsepower: Do not increase or decrease fan motor horsepower without written approval from Engineer.

Sub-Bid Contractor Update Statement. Tab A - Invitation for Bids. Tab B - Instructions to Bidders

Buildings Construction Procurement Strategy

TCTC Cabling Specifications

Pro-Lift Steel Pile Foundation Repair

Think Of Us First! When It s Time to Distribute Your Plans

Whitepaper. Modular Substation Cable Termination Design. Author: Allan Bozek P.Eng, MBA, EngWorks Inc, Calgary, Canada

IECC Compliance Guide for Homes in Virginia

KIEWIT CM/GC Enabling/Utilities

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL (352) ; FAX: (352)

UNIFIED FACILITIES GUIDE SPECIFICATIONS

2014 British Columbia Building Code Changes

HEANEY General Contracting, Inc.

BUILDING SAFETY UNIT

ESTIMATING PLUMBING, HEATING, VENTILATING, AND AIR CONDITIONING (HVAC), AND ELECTRICAL WORK

EASY$ TIP SHEETS. Energy Advice Saving Yukoners Money

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, Underground branch circuit feeding a detached garage:

Australian/New Zealand Standard

CIFECENTER FOR INTEGRATED FACILITY ENGINEERING

SECTION PIPE HANGERS AND SUPPORTS

Transcription:

ACOUSTIC ISOLATION DETAILS Icelandic National Concert and Conference Center Reykjavík, Iceland January 5, 2007 Artec Report No. 7742 Artec Project No. 3760 Distribution: Stefán Hermannsson East Harbour Project Stefán Þórarinsson, Helgi Gunnarsson Portus Group Klavs Holm Madsen, Osbjørn Jacobsen HLT Geert Stryg Rambøll Gunnlaugur Kristjánsson, Sigurður Ragnarsson, Páll Pálsson IAV

Icelandic National Concert and Conference Center Acoustic Isolation Details 1. Introduction The purpose of this report is to provide the Architect and the Engineers with acoustic isolation details. The details should be incorporated into the Detailed Design, or modified to suit a particular situation, including building practices in Iceland. Artec will review modifications or alternatives proposed by the team. We will all save time and energy if changes or alternatives are proposed for discussion before being committed to the document. Consider these details to be advice, and incorporate them into the various disciplines documents as appropriate. Artec will work with the design team to create specific details where less typical conditions occur. We have divided this report into several sections corresponding to: Structural Details Mechanical Details Electrical Details Window Details Miscellaneous Details Report no. 7742 Artec Consultants Inc Page 1

Icelandic National Concert and Conference Center Acoustic Isolation Details 2. Structural Details SD1230 SD1240 SD1250 SD1260 SD1310 SD1320 SD1340 SD1350 SD1410 SD1440 SD2110 SD2120 SD2130 SD2140 SD2150 SD2160 SD2170 SD2210 SD2220 SD2320 SD2330 SD2350 Perimeter Isolation of Non-Grade Slab - Section Acoustical Joint - Concrete on Metal Deck Construction Acoustic Joint in Suspended Concrete Slab with Proprietary Joint Cover Acoustic Joint Between Stage and Loading Area Acoustic Joint Plan Section Acoustic Joint Plan Section Acoustical Joint at Metal Decking Wall/Beam Intersection with Metal Decking Noise Critical Walls Seal at Head of Masonry Noise Critical Walls Seal at Rigid Joint (Not Acoustical Joint) Duct Penetration Through Single Sound Isolating Wall (Concrete Wall) Duct Penetration Through Single Sound Isolating Wall (Block Wall) Duct Penetration at Underside of Slab Duct Penetration Through Double Masonry Sound Isolating Walls Duct Penetration Through Double Sound Isolating Walls (Masonry + GWB) Duct Penetration Through Single/Double Sound Isolating Walls (GWB) Penetration at Bottom of Duct Shaft Wall Penetration for Pipe or Single Conduit Pipe/Conduit Penetration Through Single/Double Sound Isolation Walls Wireway Penetrations through Sound Isolation Walls for Conduits Wireway Penetrations through Sound Isolating Walls for Conduits Wall Penetration for Pipe Report no. 7742 Artec Consultants Inc Page 2

Icelandic National Concert and Conference Center Acoustic Isolation Details 3. Mechanical Details SD3120 SD3160 SD3170 SD3210 SD3220 SD3230 SD3250 SD3310 SD3320 SD3340 SD3350 SD3410 Fan Isolation (Suspended) Submersible Pump Isolation Water Closet Isolation Gypsum Board Lagging of Ducts Gypsum Board Lagging of Ducts Full Perimeter Air Diffusing Plates Elbow, Smooth Radius with Splitter Vanes Rectangular Duct Fire Damper Single Isolating Wall Fire Damper Double Isolating Wall Smoke Exhaust System Sound Isolating Smoke Vent (after BILCO ACDSH-4890) Acoustic Isolation Lagging of Pipes Report no. 7742 Artec Consultants Inc Page 3

Icelandic National Concert and Conference Center Acoustic Isolation Details 4. Electrical Details SD4110 SD4120 SD4130 SD4140 SD4150 SD4210 SD4310 SD4320 Transformer Isolation (on Grade Slab) Transformer Internal Spring Isolator Transformer on Inertia Base Isolation of Suspended Transformer Step Light Transformer Isolation Dimmer Rack Isolation Acoustically Sealed Pull Box Acoustically Sealed Pull Box Report no. 7742 Artec Consultants Inc Page 4

Icelandic National Concert and Conference Center Acoustic Isolation Details 5. Isolator Details SD5110 SD5210 SD5310 SD5410 SD5510 SD5610 SD5710 SD5720 SD5810 SD5820 SD5910 SD5920 SD5930 Constrained Spring & Neoprene Mounts Type CSNM Double Deflection Neoprene & Spring Isolation Hanger Type SPNH Spring & Neoprene Mount (SPNM) Neoprene Mounting with Captive Steel Inserts Type RBA Double Deflection Neoprene Isolation Hanger Type DDNH Double Deflection Neoprene Mounts (DDNM) Waffle Pad (WP) Metal & Waffle Pad (MWP) Concrete Inertia Base Steel Inertia Base Resilient Hold-down Assembly Hydraulic Pipe Isolation Assembly Pipe Flexible Connectors Report no. 7742 Artec Consultants Inc Page 5

Icelandic National Concert and Conference Center Acoustic Isolation Details 6. Window Detail SD7310 Acoustically Sealed Glazing Detail Report no. 7742 Artec Consultants Inc Page 6

Icelandic National Concert and Conference Center Acoustic Isolation Details 7. Miscellaneous Details SD8210 SD8220 SD8230 SD8240 Rigging Cable Pass-through for Noise Critical Wall Capped Slab Penetration for Broadcast Cables Double Door Closure for Broadcast Cable Rolite Route Acoustic Caps for Canopy Lift Line Sleeved Holes Report no. 7742 Artec Consultants Inc Page 7

Acoustic Isolation Details Index The following acoustic isolation details have been adopted for the East Harbour CCC project in Reykjavik, Iceland. These details are separated below into each discipline that relates to their execution. However, all contractors and subcontractors are responsible to follow all the acoustic isolation details as they pertain their work, even if not explicitly included in their section below. All installations in these details must be approved by the project engineers and coordinated with their engineering work. Bold items indicate details that have been issued as addenda following the original Artec report, Acoustic Isolation Details, dated January 5, 2007. Ventilation SD2110 Duct Penetration Through Single Sound Isolating Wall (Concrete Wall) SD2120 Duct Penetration Through Single Sound Isolating Wall (Block Wall) SD2130 Duct Penetration at Underside of Slab SD2140 Duct Penetration Through Double Masonry Sound Isolating Walls SD2150 Duct Penetration Through Double Sound Isolating Walls (Masonry + GWB) SD2160 Duct Penetration Through Single/Double Sound Isolating Walls (GWB) SD2170 Penetration at Bottom of Duct Shaft SD2210 Wall Penetration for Pipe or Single Conduit SD3120 Fan Isolation (Suspended) SD3180 Fan Coil or Downflow Units SD3210 Gypsum Board Lagging of Ducts SD3220 Gypsum Board Lagging of Ducts Full Perimeter SD3250 Elbow, Smooth Radius with Splitter Vanes Rectangular Duct SD3310 Fire Damper Single Isolating Wall SD3320 Fire Damper Double Isolating Wall SD3340 Smoke Exhaust System SD3350 Sound Isolating Smoke Vent (after BILCO ACDSH-4890) SD5110 Constrained Spring & Neoprene Mounts Type CSNM SD5210 Double Deflection Neoprene & Spring Isolation Hanger Type SPNH SD5310 Spring & Neoprene Mount (SPNM) SD5410 Neoprene Mounting with Captive Steel Inserts Type RBA SD5510 Double Deflection Neoprene Isolation Hanger Type DDNH SD5610 Double Deflection Neoprene Mounts (DDNM) SD5710 Waffle Pad (WP) SD5720 Metal & Waffle Pad (MWP) SD5810 Concrete Inertia Base SD5820 Steel Inertia Base SD5910 Resilient Hold-down Assembly Air Handling Units SD5110 Constrained Spring & Neoprene Mounts Type CSNM SD5210 Double Deflection Neoprene & Spring Isolation Hanger Type SPNH SD5310 Spring & Neoprene Mount (SPNM) SD5410 Neoprene Mounting with Captive Steel Inserts Type RBA SD5510 Double Deflection Neoprene Isolation Hanger Type DDNH SD5610 Double Deflection Neoprene Mounts (DDNM) SD5710 Waffle Pad (WP) Acoustic Isolation Details Index 1

SD5720 Metal & Waffle Pad (MWP) SD5810 Concrete Inertia Base SD5820 Steel Inertia Base SD5910 Resilient Hold-down Assembly Piping SD2210 Wall Penetration for Pipe or Single Conduit SD2310 Multiple Conduit/Piping penetration SD2350 Wall Penetration for Pipe SD3160 Submersible Pump Isolation SD3170 Water Closet Isolation SD3171 Water Closet Isolation Geberit SD3172 Front Elevation Detail Geberit SD3180 Fan Coil or Downflow Units SD3210 Gypsum Board Lagging of Ducts SD3220 Gypsum Board Lagging of Ducts Full Perimeter SD3410 Acoustic Isolation Lagging of Pipes SD5110 Constrained Spring & Neoprene Mounts Type CSNM SD5210 Double Deflection Neoprene & Spring Isolation Hanger Type SPNH SD5310 Spring & Neoprene Mount (SPNM) SD5320 Vertical pipe guides SD5410 Neoprene Mounting with Captive Steel Inserts Type RBA SD5510 Double Deflection Neoprene Isolation Hanger Type DDNH SD5610 Double Deflection Neoprene Mounts (DDNM) SD5710 Waffle Pad (WP) SD5720 Metal & Waffle Pad (MWP) SD5810 Concrete Inertia Base SD5820 Steel Inertia Base SD5910 Resilient Hold-down Assembly SD5911 Floor Mount Detail Geberit SD5912 Side Mount Detail - Geberit SD5920 Hydraulic Pipe Isolation Assembly SD5930 Pipe Flexible Connectors SD5940 Multiple pipe Isolation Assembly Electrical SD2210 Wall Penetration for Pipe or Single Conduit SD2220 Pipe/Conduit Penetration Through Single/Double Sound Isolation Walls SD2310 Multiple Conduit/Piping penetration SD2320 Wireway Penetrations through Sound Isolation Walls for Conduits SD2330 Wireway Penetrations through Sound Isolating Walls for Conduits SD4110 Transformer Isolation (on Grade Slab) SD4120 Transformer Internal Spring Isolator SD4130 Transformer on Inertia Base SD4140 Isolation of Suspended Transformer SD4150 Step Light Transformer Isolation SD4210 Dimmer Rack Isolation SD4310 Acoustically Sealed Pull Box SD4320 Acoustically Sealed Pull Box SD5110 Constrained Spring & Neoprene Mounts Type CSNM SD5210 Double Deflection Neoprene & Spring Isolation Hanger Type SPNH SD5310 Spring & Neoprene Mount (SPNM) SD5320 Vertical pipe guides Acoustic Isolation Details Index 2

SD5410 Neoprene Mounting with Captive Steel Inserts Type RBA SD5510 Double Deflection Neoprene Isolation Hanger Type DDNH SD5610 Double Deflection Neoprene Mounts (DDNM) SD5710 Waffle Pad (WP) SD5720 Metal & Waffle Pad (MWP) SD5810 Concrete Inertia Base SD5820 Steel Inertia Base SD5910 Resilient Hold-down Assembly Box-in-box and Acoustic Joints and Noise-Critical Structures SD1230 Perimeter Isolation of Non-Grade Slab - Section SD1240 Acoustical Joint - Concrete on Metal Deck Construction SD1250 Acoustic Joint in Suspended Concrete Slab with Proprietary Joint Cover SD1260 Acoustic Joint Between Stage and Loading Area SD1310 Acoustic Joint Plan Section SD1320 Acoustic Joint Plan Section SD1340 Acoustical Joint at Metal Decking SD1350 Wall/Beam Intersection with Metal Decking Noise Critical Walls SD1410 Seal at Head of Masonry Noise Critical Walls SD1440 Seal at Rigid Joint (Not Acoustical Joint) SD5110 Constrained Spring & Neoprene Mounts Type CSNM SD5210 Double Deflection Neoprene & Spring Isolation Hanger Type SPNH SD5310 Spring & Neoprene Mount (SPNM) SD5410 Neoprene Mounting with Captive Steel Inserts Type RBA SD5510 Double Deflection Neoprene Isolation Hanger Type DDNH SD5610 Double Deflection Neoprene Mounts (DDNM) SD5710 Waffle Pad (WP) SD5720 Metal & Waffle Pad (MWP) SD5810 Concrete Inertia Base SD5820 Steel Inertia Base SD5910 Resilient Hold-down Assembly SD5920 Hydraulic Pipe Isolation Assembly SD5930 Pipe Flexible Connectors SD7310 Acoustically Sealed Glazing Detail SD8210 Rigging Cable Pass-through for Noise Critical Wall SD8220 Capped Slab Penetration for Broadcast Cables SD8230 Double Door Closure for Broadcast Cable Rolite Route SD8240 Acoustic Caps for Canopy Lift Line Sleeved Holes END OF DOCUMENT Acoustic Isolation Details Index 3