Reducing Network Documentation Effort by Visio Automation. David Cuthbertson



Similar documents
Applying Visio Automation Techniques to Network and Infrastructure Documentation. David Cuthbertson

Visio Automation For Data Centres and Network Infrastructure. David Cuthbertson Square Mile Systems / AssetGen

Diagramming ITS Infrastructure and ITIL Services with Visio

Change, Configuration and Release Management Techniques for Data Centers

Infrastructure Configuration Management Techniques. Neal R. Firth VIZIM Worldwide, Inc.

Managing Change in Critical IT Infrastructure

Data Center Visualization Using Visio

CMDB Visualization Using Visio

Square Mile Systems Ltd.

Advanced planning / change impact features

Visualizing Data Center Capacity with Visio

Documenting and Managing Infrastructure Connectivity

Product Comparison List

Microsoft Visio 2010 Top 10 Benefits

DATA CENTER INFRASTRUCTURE MANAGEMENT

Model Driven Business Architecture. Pete Rivett CTO, Adaptive

Product Comparison List

Model Manage Monitor Maximize your Data Center

Data Center Infrastructure Management (DCIM) Demystified

Quareo ICM Server Software

Monitoring Inventory. Inventory Management. This chapter includes the following sections:

White Paper on netterrain, An Automated, Graphical IT Documentation System Published by Graphical Networks

Developing the Corporate Security Architecture. Alex Woda July 22, 2009

Working with the New Visio Methodology

DATA CENTER INFRASTRUCTURE MANAGEMENT

T-BOXN12R. First steps with T-BOXN12R. You can make it wireless. Date: Version 1.0

Ultra Thin Client TC-401 TC-402. Users s Guide

Visio 2010 Tips and Techniques

ALTIRIS TOPOLOGY VIEWER 6.0 PRODUCT GUIDE

Attix5 Pro Server Edition

Chapter 4 Control Center

integrated lights-out in the ProLiant BL p-class system

Document Management User Guide

NMS300 Network Management System

13 Managing Devices. Your computer is an assembly of many components from different manufacturers. LESSON OBJECTIVES

Microsoft Visio 2010 Business Intelligence

Software for Agilent Technologies Vector Series Network Analyzers

DUKANE Intelligent Assembly Solutions

Optimally Manage the Data Center Using Systems Management Tools from Cisco and Microsoft

14.1. bs^ir^qfkd=obcib`qflk= Ñçê=emI=rkfuI=~åÇ=léÉåsjp=eçëíë

ACME Enterprises IT Infrastructure Assessment

Dell UPS Local Node Manager USER'S GUIDE EXTENSION FOR MICROSOFT VIRTUAL ARCHITECTURES Dellups.com

WhatsUpGold. v3.0. WhatsConnected User Guide

HP Client Automation Standard Fast Track guide

Lab Diagramming Intranet Traffic Flows

Information in this document, including URL and other Internet Web site references, is subject to change without notice. Unless otherwise noted, the

Working with Visio Connectors

Cisco ROSA Video Service Manager (VSM) Version 05.03

Multi-Profile CMOS Infrared Network Camera

The role of Access and Control in DCIM

Network Manager 6.1. Network operations management software. NEC Corporation


Emerson Smart Firewall

smart-house Web-Server Manual smart-house Web-Server Manual Version 1.03

Creating Basic Custom Monitoring Dashboards Antonio Mangiacotti, Stefania Oliverio & Randy Allen

Internet User Guide. For the ZTE H298N routers. LAN4 LAN3 LAN2 LAN1 WAN Phone USB2 USB2 WAN WLAN WLAN WLAN

6.0. Getting Started Guide

EasyMP Multi PC Projection Operation Guide

THE. solution. STORe it. SHARE it.

Table of Contents. Chapter1. Introduction Before Installation System Requirements... 1

Datacenter Infrastructure Management (DCIM) Solution

THE MOLEX REAL TIME PATCHING SYSTEM. The only connectivity management solution you can trust for the long term.

SIP Proxy Server. Administrator Installation and Configuration Guide. V2.31b. 09SIPXM.SY2.31b.EN3

HP Server Management Packs for Microsoft System Center Essentials User Guide

Quick Installation Guide

Cisco 831 Router and Cisco SOHO 91 Router Cabling and Setup Quick Start Guide

Additional Requirements for ARES-G2 / RSA-G2. One Ethernet 10 Base T/100 Base TX network card required for communication with the instrument.

Sage Intelligence Financial Reporting for Sage ERP X3 Version 6.5 Installation Guide

Virtual Data Centre. User Guide

How To Use An Easymp Network Projector On A Computer Or Network Projection On A Network Or Network On A Pc Or Mac Or Ipnet On A Laptop Or Ipro Or Ipo On A Powerbook On A Microsoft Computer On A Mini

Virtual CD v10. Network Management Server Manual. H+H Software GmbH

Getting Started Guide SAGE ACCPAC INTELLIGENCE

EasyMP Monitor Operation Guide Ver.4.53

Package Contents. D-Link DSN-3200/3400 Installation Guide. DSN-3200/3400 xstack Storage Area Network (SAN) Array. CD-ROM with User Guide.

Ovation Operator Workstation for Microsoft Windows Operating System Data Sheet

Configuration Management: Best Practices White Paper

ION Tips and Tricks. Q&A Session PowerLogic ION Users Conference 2009

Lenovo Partner Pack for System Center Operations Manager

EasyMP Network Projection Operation Guide

IOmark- VDI. HP HP ConvergedSystem 242- HC StoreVirtual Test Report: VDI- HC b Test Report Date: 27, April

InfoView User s Guide. BusinessObjects Enterprise XI Release 2

Easy Data Centralization with Webster. User Guide

Web site:

How To Use The Numara Track-It! Help Desk And Asset Management Solution

Configuring and Managing Token Ring Switches Using Cisco s Network Management Products

Communication and connectivity the ideal solution for integrated system management and data integrity

Package Contents. D-Link DSN-3200/3400 Installation Guide. DSN-3200/3400 xstack Storage Area Network (SAN) Array. CD-ROM with User Guide.

Required Virtual Interface Maps to... mgmt0. virtual network = mgmt0 wan0. virtual network = wan0 mgmt1. network adapter not connected lan0

Kevin Kochirka, ABB Turbine Automation, June 29, Flexible turbine control retrofits Webinar

Student Halls Network. Connection Guide

QuickSpecs. Overview. Compaq Remote Insight Lights-Out Edition

BI solutions with Visio Graphical visualizations with Visio, SharePoint and Visio Services

Digital Advisory Services Professional Service Description Network Assessment

How To Compare Two Servers For A Test On A Poweredge R710 And Poweredge G5P (Poweredge) (Power Edge) (Dell) Poweredge Poweredge And Powerpowerpoweredge (Powerpower) G5I (

Management of VMware ESXi. on HP ProLiant Servers

Transcription:

Reducing Network Documentation Effort by Visio Automation David Cuthbertson

Diagrams Are Very Useful!

But Not all Diagrams Help! 3

If A Picture Paints a Thousand Words How do we paint a thousand pictures? Easily?

Reducing Your Workload Architecture Overviews LAN/WAN/SAN Diagrams Inventory / Connection Lists Automation Current Method Floor & Rack Diagrams 0% 20% 40% 60% 80% 100%

Visio Automation Agenda 1. Understand Visio out of the box 2. Diagramming techniques - Making it simpler for all 3. Linking Visio to data sources - Reduce cut/paste, diagram refresh, consistency 4. Automation for larger infrastructures - Automated creation and updating

A Few Questions Who has used Visio for more than 2 years? Which is easier and faster to complete? a. Drawing a Visio diagram at a planning stage b. Drawing a Visio diagram of an existing network Is it possible to get different engineers to draw the same Visio diagrams?

Visio history 1. Visio Basics 1992 First released, 2000 acquired by Microsoft Last non-ms versions had auto-discovery, equipment templates all removed with Visio 2003 Versions Visio 2007/10/13 Standard Visio 2007/10/13 Professional Visio 2010/13 Premium Visio 2007/10/13 Viewer (runs in IE browser) 8

Visio Version Comparison 9

Visio Features 10

Data Features 11

Visio Resources And Help Microsoft web site Books LinkedIn group Visio Enthusiasts Equipment manufacturer web sites Cisco, Commscope, Siemon HP, Dell, IBM, others www.visiocafe.com 3rd Party stencils netzoom, others www.altimatech.com Visioguy www.visguy.com

Templates, Stencils, Shapes Categories Templates Stencils 42 U 8 U 2 U 2 U 3 U 1 U 4 U 1 U 2 U 8 U 2 U 2 U Shape

Visio Concepts and terms Template Stencil Shape Shape properties Connector Background Layer RTR-BHAM-01 SW-BHAM-01 Properties Cisco 2950 10.6.2.32 Live Data Centre Comms Room

Visio Basics -1 Creating new diagram from a template Manipulating shapes on a page Aligning and Distributing Shapes Copy, Paste and Duplicate Shapes Grouping and ungrouping shapes Foreground and Background options Zooming in and Out of the Page Using the Drawing Toolbar to create basic shapes 15

Visio Basics - 2 Connectors Static and dynamic glue Adding, deleting and moving connector points Using different stencils Stencil search Shape behaviour -1d, 2d, drill down Working with text Object text Freeform text Text block tool 16

Static glue Static glue is to a particular connection point The connection points used don t move even if the shapes are moved 17

Dynamic glue Drag connector onto shape and wait until shape is highlighted in red If you move the shapes relative to each other the connection moves appropriately 18

Using Different Stencils (and searching) Use Shapes tab Select via menus Use Search options External stencil sets Suppliers, 3 rd party 19

Using External /3 rd Party Stencils There are lots to choose from Free www.visiocafe.com many suppliers sets Manufacturers Cisco, etc. 3 rd Party custom sets Purchase NetZoom Other products with embedded stencils / graphics

Danger! - Visio File Sizes Two files Diagram 1 Diagram 2 1995kB 12kB Diagram 1 is 166 times the size of Diagram 2! Some tips to reduce file sizes 21

2. Diagramming Techniques Good diagramming practice 1. The detail that you see - What is seen visually / printed 2. Additional data / information within diagram - Additional action by viewer display, click, show layer, etc. 3. How you get to other information? - Drill down, open files, launch remote session 22

The Process of Creating a Diagram 1. Purpose 2. 3. 4. 5. 6. 7. 8. Gather data Define shapes Transfer data to diagram Layout Add extra detail Save Send / publish diagram 1. Which takes the most time? 2. Where can errors creep in?

Diagram Process Examples Switches / Router in Orlando WS-X6K-SUP1A-2GE 1 ACTIVE STATUS Select Rack R01 Inventory SYSTEM Gather data PWR MGMT 2. Network Diagram Orlando LAN RESET Rack Diagram R01 DTE/DCE 1. Purpose SW-BHAM-CORE1.Card1 PORT 1 100% 1% SWITCH LOAD CONSOLE SUPERVISOR 1 PCMCIA PORT 2 LINK EJECT LINK FAN STATUS 2 WS-X6716-10T 3 STATUS PORT 1 PORT 2 PORT 3 PORT 4 SW-BHAM-CORE1.Card3 PORT 5 PORT 6 PORT 7 PORT 8 PORT 9 PORT 10 PORT 11 PORT 12 PORT 13 PORT 14 PORT 15 PORT 16 16 PORT 10 GbE MODULE WS-X6748-GE-TX 1 11 2 1314 23 24 12 25 35 26 3738 47 36 48 SW-BHAM-CORE1.Card4 4 10/100/1000 GE MOD 48 PORT STATUS WS-X6748-GE-TX 1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12 1 11 2 13 14 15 13 14 15 16 17 18 19 20 21 22 23 24 1314 23 24 12 25 26 27 28 29 30 31 32 33 34 35 36 33 34 35 36 25 FABRIC ENABLED RJ45 35 26 37 38 39 40 41 42 43 44 45 46 47 48 37 38 39 40 41 42 43 44 45 46 47 48 3738 47 36 48 SW-BHAM-CORE1.Card5 5 10/100/1000 GE MOD 48 PORT STATUS 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 FABRIC ENABLED RJ45 6 3. Define shapes Match to Physical Shapes Match to Logical Shapes 7 8 WS-X6716-10T 9 STATUS C6509-E-FAN PORT 1 PORT 2 PORT 3 PORT 4 PORT 5 SW-BHAM-CORE1.Card9 PORT 6 PORT 7 PORT 8 PORT 9 PORT 10 PORT 11 PORT 12 PORT 13 PORT 14 PORT 15 PORT 16 16 PORT 10 GbE MODULE WS-C6509-E INPUT 1 100-240V ~ 16A 60/50 Hz INPUT 1 100-240V ~ 16A 60/50 Hz INPUT 2 100-240V ~ 16A 60/50 Hz INPUT 2 100-240V ~ 16A 60/50 Hz RUN LL INSTA RUN LL INSTA INPUT OK 1 CISCO SYSTEMS, INC. FAN OK 2 OUTPUT FAIL SW-BHAM-CORE1 SWITCH MUST BE IN OFF O POSITION TO INSTALL/ REMOVE POWER SUPPLY. FASTENER MUST BE FULLY ENGAGED PRIOR TO OPERATING POWER SUPPLY. CISCO SYSTEMS, INC. INPUT OK 1 FAN OK OUTPUT FAIL 2 SWITCH MUST BE IN OFF O POSITION TO INSTALL/ REMOVE POWER SUPPLY. FASTENER MUST BE FULLY ENGAGED PRIOR TO OPERATING POWER SUPPLY. 440 mic r os y s tems CRITICAL MAJOR MINOR I USER 4. Transfer data to diagram Create Shapes Create Shapes and connections 5. Layout Place/size to position in rack Move/size for readability 6. Add extra detail Notes, etc. Notes, etc. 7. Save Save as Rack R01 Save as Orlando LAN 8. Send / publish diagram Store on server Intranet/SharePoint Store on server Intranet/SharePoint CO MPACT SW-BHAM-Trade01

Is This A Good Diagram? Contoso, Inc. IT Purchase Request Sales team proposed expansion Windows Server 2003, Datacenter Edition CPU (MHz) 3 Memory (MB) 2048 Windows Storage Server 2003 CPU (MHz) 1.4 IP Address 10.0.1.51 sql-sales-01 Memory (MB) 1024 IP Address 10.0.1.5 filestore-sales-01 Windows Server 2003, Datacenter Edition CPU (MHz) 3.2 web-sales-02 Administrator Don Hall Memory (MB) 2560 Windows Storage Server 2003 CPU (MHz) 1.26 IP Address 10.0.1.52 sql-sales-02 Memory (MB) 768 IP Address 10.0.1.6 filestore-sales-02 Windows Server 2003, Datacenter Edition CPU (MHz) 3 web-sales-03 Administrator Don Hall Windows Server 2003, Standard Edition CPU (MHz) 2 Memory (MB) 2048 IP Address 10.0.1.53 sql-sales-03 Memory (MB) 1536 IP Address 10.0.1.14 ftp-sales-01 25

Does It Have These Characteristics? 1. Title 2. Purpose Contoso, Inc. IT Purchase Request Sales team proposed expansion 3. Author Windows Server 2003, Datacenter Edition CPU (MHz) 3 4. Version Windows Storage Server 2003 CPU (MHz) 1.4 Memory (MB) 2048 IP Address 10.0.1.51 sql-sales-01 5. Date 6. Instructions 7. Symbols 8. Attributes 9. Connections Memory (MB) 1024 IP Address 10.0.1.5 Windows Storage Server 2003 CPU (MHz) 1.26 Memory (MB) 768 IP Address 10.0.1.6 Windows Server 2003, Standard Edition CPU (MHz) 2 filestore-sales-01 filestore-sales-02 Windows Server 2003, Datacenter Edition CPU (MHz) 3.2 Memory (MB) 2560 IP Address 10.0.1.52 Windows Server 2003, Datacenter Edition CPU (MHz) 3 Memory (MB) 2048 IP Address 10.0.1.53 sql-sales-02 sql-sales-03 web-sales-02 Administrator Don Hall web-sales-03 Administrator Don Hall 10. Grouping Memory (MB) 1536 IP Address 10.0.1.14 ftp-sales-01 11. Background / layers 26

Enterprise Architecture Zackman Framework perspectives abstractions DATA What FUNCTION How NETWORK Where PEOPLE Who MOTIVATION Why SCOPE Planner List of Things - Important to the Business List of Processes - the Business Performs List of Locations - in which the Business Operates List of Organizations - Important to the Business List of Events - Significant to the Business List of Business Goals and Strategies contextual Entity = Class of Business Thing Function = Class of Business Process Node = Major Business Location People = Class of People and Major Organizations Time = Major Business Event Ends/Means=Major Business Goal/Critical Success Factor e.g., Semantic Model e.g., Business Process Model e.g., Logistics Network e.g., Work Flow Model e.g., Master Schedule e.g., Business Plan ENTERPRISE MODEL Owner conceptual Entity = Business Entity Rel. = Business Relationship Process = Business Process I/O = Business Resources Node = Business Location Link = Business Linkage People = Organization Unit Work = Work Product Time = Business Event Cycle = Business Cycle End = Business Objective Means = Business Strategy SYSTEM MODEL Designer e.g., Logical Data Model e.g., Application Architecture e.g., Distributed System Architecture e.g., Human Interface Architecture e.g., Processing Structure e.g., Business Rule Model logical Entity = Data Entity Rel. = Data Relationship Process.= Application Function I/O = User Views Node = IS Function Link = Line Characteristics People = Role Work = Deliverable Time = System Event Cycle = Processing Cycle End = Structural Assertion Means =Action Assertion e.g., Physical Data Model e.g., System Design e.g., Technical Architecture e.g., Presentation Architecture e.g., Control Structure e.g., Rule Design TECHNOLOGY CONSTRAINED MODEL Builder physical Entity = Tables/Segments/etc. Rel. = Key/Pointer/etc. e.g. Data Definition Process= Computer Function I/O =Data Elements/Sets e.g. Program Node = Hardware/System Software Link = Line Specifications e.g. Network Architecture People = User Work = Screen/Device Format e.g. Security Architecture Time = Execute Cycle = Component Cycle e.g. Timing Definition End = Condition Means = Action e.g. Rule Specification DETAILED REPRESEN- TATIONS Subcontractor out-of-context Entity = Field Rel. = Address Process= Language Statement I/O = Control Block Node = Addresses Link = Protocols People = Identity Work = Job Time = Interrupt Cycle = Machine Cycle End = Sub-condition Means = Step FUNCTIONING ENTERPRISE DATA Implementation FUNCTION Implementation NETWORK Implementation ORGANIZATION Implementation SCHEDULE Implementation STRATEGY Implementation

Visio Examples Floor plans Importing CAD / other formats Layers Data center floor plans Backgrounds Hyperlinking

3. Linking Visio To Data Sources Saves typing mistakes Enables refresh of data One diagram can serve multiple purposes Less to maintain Multiple views of one device Less to maintain Enables use Of Data Graphics Feature

Understanding Reality To understand infrastructure and manage change We need multiple views Rack schematics Equipment configuration Physical connectivity Logical end point connectivity End device connectivity

BLAD E -B IR M 01.BLA D E -SW 1 U K _ B IR M 0 1 _ B L A D E -0 1 U K _ B IR M 0 1 _ B L A D E -0 9 U K _ B IR M 0 1 _ B L A D E -0 2 U K _ B IR M 0 1 _ B L A D E -1 0 U K _ B IR M 0 1 _ B L A D E -0 3 B L A D E _ B IR M 01 U K _ B IR M 0 1 _ B L A D E -0 4 U K _ B IR M 0 1 _ B L A D E -1 2 U K _ B IR M 0 1 _ B L A D E -0 5 BLAD E -B IR M 01.BLA D E -SW 2 Multiple Device Instances in Diagrams Claims Processing Accounts Receivable Accounts Payable Payroll NTU-TEST03 Payment Module Accounts Module Sage Payroll RTR-BHAM-01 Rack Position ACCOUNTS PAYROLL NTU-BHAM-01 Floor Plan PP01-02-01 PWR01-02-B PWR01-02-A H/W Build SVRWIN001 Service view UK_BIRMCC_PDU1 SW-BHAM- CORE1 SW-BHAM- CORE2 9 9 9 9 9 PWR01-03-A PWR01-04-A PWR01-05-A PWR01-06- A PWR01-07-A SW-BHAM-01 SW-BHAM-03 SW-BHAM-06 SW-BHAM-05 SW-BHAM-04 SW-BHAM-02 UK_BIRM_UX01 UK_BIRM_UX02 UK_BIRM_UX09 UK_BIRM_UX10 UK_BIRM_UX03 Power Supply UK_BIRM_UX05 UK_BIRM_UX07 UK_BIRM_UX04 UK_BIRM_UX06 UK_BIRM_UX08 PWR01-03-B PWR01-04- B PWR01-05- B PWR01-06- B PWR01-07- B Network Connections UK_BIRM_UX01 UK_BIRM_UX02 UK_BIRM_UX09 UK_BIRM_UX05 UK_BIRM_UX03 UK_BIRM_UX06 UK_BIRM_UX07 UK_BIRM_UX04 UK_BIRM_UX08 UK_BIRM_UX10 9 9 9 UK_BIRMCC_PDU2 9 9 31

Reduce The Workload! Excel Visio Floor box list Cabinet list Patch panel list Inventory Inventory Inventory Floor plan Equipment room floor plan Backbone cabling diagram Network diagram Rack diagram Server connectivity diagram

Using External Data Sources New Updating 1. Purpose 1. Purpose 2. 3. Gather data Define shapes Time saving 2. 3. Gather data Check diagram for match 4. Transfer data to diagram 4. Add / Delete shape Connector, Data 5. Layout 5. Review Layout 6. Add extra detail 6. Add extra detail 7. Save 7. Save 8. Send / publish diagram 8. Send / publish diagram

Visio Data Graphics Standard feature 2007/10/13 Professional Enables use of embedded data Display multiple text fields around a shape Data bars to show capacity Use icons for status differences Change shape colour based on data value 01-03 01-03 01-03 Server 32 20 3330

Limitations Of Visio / Data Source Good for quick diagrams The data transfer and refresh is automated, but the filtering and selection is manual It doesn t connect shapes together Limits value in a network environment New devices are not added to diagrams

First Steps For Multiple Diagrams Control use of shapes / stencils Follow best practices for diagram information Save reference versions in common areas File locations Web site SharePoint Use a common source where possible for shape data Databases preferred to spreadsheets Create views to suit diagram information need 36

4. Automation For Larger Infrastructures Looking beyond a few spreadsheets Minimise manual maintenance effort Scale and separation of roles demands it Improving accuracy and consistency Software driven diagram production Infrastructure document management Shared across teams, controlled access

Extending Visio Automation New Updating 1. Purpose 1. Purpose 2. 3. Gather data Define shapes Time saving 2. 3. Gather data Check diagram for match 4. Transfer data to diagram 4. Add / Delete shape Connector, Data 5. Layout 5. Review Layout 6. Add extra detail 6. Add extra detail 7. Save 7. Save 8. Send / publish diagram 8. Send / publish diagram

Simple Goals Draw 60 rack diagrams and save on a file server by room location Check and update 100 site network diagrams with changes in devices, connections and data Refresh an updated set of build documents covering racks, hardware, cabling, power within a data center transition project When now, tonight, every Friday

Many Infrastructure Information Needs Plan Build Operate Risk Dispose Project and tasks Ease and speed of creation Ease of distribution Flexible to meet task needs Limited training Examples Project documentation Equipment lists Visio/CAD diagrams Test results Operations And Risk Control Ease of use by many Structured for integration & reporting Support for multiple processes Wide scope the big picture! Examples Asset and Inventory management Business / service dependencies Monitoring of performance, status Risk and Recovery 40

Leverage Data Sources Plan Build Operate Risk Dispose Documents Lists Diagrams CMDB NMS IIM CMS SAM DCIM Knowledge Contracts Monitoring Workflow Capacity Data Storage Inventory Networks Cabling Power Excel Visio Dave(s) 41

Maintain - Infrastructure Knowledge Plan Build Operate Risk Dispose Project and tasks Ease and speed of creation Ease of distribution Flexible to meet task needs Limited training Operations And Risk Control Ease of use by many Structured for integration & reporting Support for multiple processes Wide scope the big picture! Record planning decisions in the operational system Produce project docs for/from the operational system 42

Diagram Automation Examples Switches / Router in Orlando WS-X6K-SUP1A-2GE 1 ACTIVE STATUS Select Rack R01 Inventory SYSTEM Gather data PWR MGMT 2. Network Diagram Orlando LAN RESET Rack Diagram R01 DTE/DCE 1. Purpose SW-BHAM-CORE1.Card1 PORT 1 100% 1% SWITCH LOAD CONSOLE SUPERVISOR 1 PCMCIA PORT 2 LINK EJECT LINK FAN STATUS 2 WS-X6716-10T 3 STATUS PORT 1 PORT 2 PORT 3 PORT 4 SW-BHAM-CORE1.Card3 PORT 5 PORT 6 PORT 7 PORT 8 PORT 9 PORT 10 PORT 11 PORT 12 PORT 13 PORT 14 PORT 15 PORT 16 16 PORT 10 GbE MODULE WS-X6748-GE-TX 1 11 2 1314 23 24 12 25 35 26 3738 47 36 48 SW-BHAM-CORE1.Card4 4 10/100/1000 GE MOD 48 PORT STATUS WS-X6748-GE-TX 1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12 1 11 2 13 14 15 13 14 15 16 17 18 19 20 21 22 23 24 1314 23 24 12 25 26 27 28 29 30 31 32 33 34 35 36 33 34 35 36 25 FABRIC ENABLED RJ45 35 26 37 38 39 40 41 42 43 44 45 46 47 48 37 38 39 40 41 42 43 44 45 46 47 48 3738 47 36 48 SW-BHAM-CORE1.Card5 5 10/100/1000 GE MOD 48 PORT STATUS 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 FABRIC ENABLED RJ45 6 3. Define shapes Match to Physical Shapes Match to Logical Shapes 7 8 WS-X6716-10T 9 STATUS C6509-E-FAN PORT 1 PORT 2 PORT 3 PORT 4 PORT 5 SW-BHAM-CORE1.Card9 PORT 6 PORT 7 PORT 8 PORT 9 PORT 10 PORT 11 PORT 12 PORT 13 PORT 14 PORT 15 PORT 16 16 PORT 10 GbE MODULE WS-C6509-E INPUT 1 100-240V ~ 16A 60/50 Hz INPUT 1 100-240V ~ 16A 60/50 Hz INPUT 2 100-240V ~ 16A 60/50 Hz INPUT 2 100-240V ~ 16A 60/50 Hz RUN LL INSTA RUN LL INSTA INPUT OK 1 CISCO SYSTEMS, INC. FAN OK 2 OUTPUT FAIL SW-BHAM-CORE1 SWITCH MUST BE IN OFF O POSITION TO INSTALL/ REMOVE POWER SUPPLY. FASTENER MUST BE FULLY ENGAGED PRIOR TO OPERATING POWER SUPPLY. CISCO SYSTEMS, INC. INPUT OK 1 FAN OK OUTPUT FAIL 2 SWITCH MUST BE IN OFF O POSITION TO INSTALL/ REMOVE POWER SUPPLY. FASTENER MUST BE FULLY ENGAGED PRIOR TO OPERATING POWER SUPPLY. 440 mic r os y s tems CRITICAL MAJOR MINOR I USER 4. Transfer data to diagram Create Shapes Create Shapes and connections 5. Layout Place/size to position in rack Move/size for readability 6. Add extra detail Notes, etc. Notes, etc. 7. Save Save as Rack R01 Save as Orlando LAN 8. Send / publish diagram Store on server Intranet/SharePoint Store on server Intranet/SharePoint CO MPACT SW-BHAM-Trade01

Simplify Infrastructure Data Capture Data capture focusses on delivering database load files Visualization is either created automatically, or by combining data with existing backdrops - floor plans No need to check across multiple diagrams / documents for consistency and format A faster, less complex and less costly audit, which doesn t require high skill levels within the audit team as the software system creates the visualization Excel Building Excel Rack Excel Device Excel Cable

Making Trusted Data A Reality 1. Establish policies, standards and ownership of data and diagrams. Make it simpler and easier for engineers and managers 2. Have project / operations use common terms & formats Supply templates, naming system, labels, etc. 3. Reduce the numbers of documents / files to maintain Consolidate into centralised systems and make them easy to find Link / create / update Visio diagrams, reports, excel from databases 4. Update operational systems as part of planning processes

Review From The Start Architecture Overviews LAN/WAN/SAN Diagrams Inventory / Connection Lists Automation Current Method Floor & Rack Diagrams 0% 20% 40% 60% 80% 100%

Visio Automation Tips and Techniques Lots of productivity features are unknown Save yourself and others a lot of effort! Learn more about Visio Linking to existing data sources has many benefits Less errors, easier to refresh diagrams and update them Use the data graphics feature to reduce diagram numbers For larger environments Assess the value of database driven systems

Additional Material www.microsoft.com http://blogs.office.com/b/visio/ https://www.facebook.com/microsoftvisio www.squaremilesystems.com Free SMS Visio utilities Downloads and videos Webinars/videos Visio automation, documenting cabling, etc. www.assetgen.com Evaluation software Free DCIM/CMS evaluation version Webinars Data center practices, Visio integration