10Gbps XFP Bi-Directional Transceiver, 10km Reach 1270/1330nm TX / 1330/1270 nm RX

LONGLINE 2km XFP Optical Transceiver

Product Specification. RoHS-6 Compliant 10Gb/s 850nm Multimode Datacom XFP Optical Transceiver FTLX8512D3BCL

LONGLINE 40km XFP Optical Transceiver

How To Connect A 10Gbps Sfp+ Bi-Directional Transceiver To A Single Mode Fiber With A Single Power Cell (Sfp+) To A Power Cell With A Power Source (Sf) (Sfl) (

8.5Gb/s SFP+ Fibre Channel Optical Transceiver

Product Specification. OC-12 LR-1/STM L-4.1 RoHS Compliant Pluggable SFP Transceiver. FTLF1422P1xTL

2.488Gbps Compact Bi-Di SFP Transceiver, 20km Reach 1490nm TX / 1310 nm RX

SFP+ LR 10G Ethernet 10km SFP+ Transceiver 10GBASE-LR / 10BBASE-LW

10GBASE-LR XFP Optical Transceiver AXM752

LONGLINE 10Gbps 10km SFP+ Optical Transceiver

10GBASE-SR XFP Optical Transceiver AXM751

155Mbps/1250Mbps SFP Bi-Directional Transceiver, 40km Reach 1310nm TX / 1550 nm RX

DTSB35(53)12L-CD20 RoHS Compliant 1.25G 1310/1550nm(1550/1310nm) 20KM Transceiver

1.25Gbps GBIC Optical Transceiver, 20km Reach

4.25Gbps SFP Optical Transceiver, 30km Reach

PART NUMBER INPUT/OUTPUT SIGNAL DETECT VOLTAGE TEMPERATURE

LONGLINE QSFP+ SR4. Features. Applications. Description. Page 1 of 13

Modultech MT-XDFx-xx192-08(04)CD 80 (40) km DWDM XFP module with built-in FEC wrapper Description

155Mbps DFB SFP Optical Transceiver, 120km Reach

Product Specification ps/nm (~200km) DWDM XFP Optical Transceiver FTLX4213x3xxxx

SFP-SX with DOM 1.25Gb/s Multi-Mode SFP Transceiver 1000BASE-SX Gb/s Fiber Channel

10Gb/s SFP+ LRM 1310nm FP with PIN Receiver 220meters transmission distance

Product Specification 10Gb/s BIDI SFP+ Transceiver

Produto: 1.25Gbps SFP Bi-Directional Transceiver, 10km Reach (1310nm TX/1550nm RX) Modelo: V7-WDM-0210AD Documentação: Técnica/Datasheet

1000BASE-T and 10/100/1000BASE-T Copper SFP Transceiver

Methode Electronics. DM-317-XXXX 40 Gbps QSFP+ Passive Cable RoHS COMPLIANT.

X2 LR Optical Transponder, 10Km Reach

SFP+ DWDM Dual LC 10G SMF 40km Transceiver. Features. Applications APPLIED OPTOELECTRONICS, INC. A7ELXDxxEDMA0609

DWDM SFP Series. Power budget* (note2) Laser

DWDM SFP Series. Power budget* (note2) Laser

10GBASE -LRM, 220m Reach GX LRMC

Dual Fiber SFP Series

GPON OLT Optical Transceiver SFP Module RTXM Features

Product Specification. 1000BASE-T RoHS Compliant Copper SFP Transceiver FCLF8520P2BTL / FCLF8521P2BTL / FCLF8522P2BTL

SFP-TX 1000BASE-T SFP Transceiver 10/100/1000M SFP Transceiver

10/100/1000BASE-T SFP Transceiver

SO-QSFP28-LR4. QSFP, 100GBASE-LR, SM, DDM, 10km, LC SO-QSFP28-LR4 OVERVIEW PRODUCT FEATURES APPLICATIONS ORDERING INFORMATION DATASHEET 4.

SFP-GIG-SX 1000BASE-SX, Jusqu à 550 mètres de distance opérationnelle, Longueur d onde Laser 850nm, Fibre Multimode (MMF), SFP Optique Insérable

10/100BASE-T Copper Transceiver Small Form Pluggable (SFP), 3.3V 100 Mbps Fast Ethernet. Features. Application

RoHS Compliant Copper Small Form Factor Pluggable (SFP) Transceiver for Gigabit Ethernet

Fast Ethernet 100BASE-LX10 SFP Single Mode Transceivers with Digital Diagnostics

Intel Ethernet SFP+ Optics

Methode Electronics. DM-338-GG-XXXX Up to 120 Gbps CXP Passive Cable Assembly.

EPON ONU Optical Transceiver SFF Module

1000BASE-BX-OLT Transceiver

155Mbps ATM-Single Mode Transceiver

GBIC CWDM 40km Part no:

SO-CFP-ER-DWDM. CFP, 103/112 Gbps, DWDM tunable, SM, DDM, 20km SO-CFP-ER4-DWDM OVERVIEW PRODUCT FEATURES APPLICATIONS ORDERING INFORMATION

1250Mbps Gigabit Interface Converters (GBIC) Transceiver Module for Gigabit Ethernet

Enabling the Business Continuity & Change the way business communicates

NTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter

Prisma IP 10 GbE VOD Line Card

WaveReady CFM. Optical Link Monitoring System: Continuous Fiber Monitor

RoHS compliant 1310 nm multi-mode Transceiver (2 km) 1x9, ST Duplex Plastic Connector, 3.3 V 155 Mbps ATM/ Fast Ethernet

VITESSE SEMICONDUCTOR CORPORATION. 16:1 Multiplexer. Timing Generator. CMU x16

Part No. Data Rate Wavelength Interface Temp. DDMI

Cisco SFP Optics for Gigabit Ethernet Applications

155 Mb/s Fiber Optic Light to Logic Receivers for OC3/STM1

DATA SHEET. TDA1518BQ 24 W BTL or 2 x 12 watt stereo car radio power amplifier INTEGRATED CIRCUITS

Accurate Loss-of-Signal Detection in 10Gbps Optical Receivers using the MAX3991

Data Sheet. HFBR-0600Z Series SERCOS Fiber Optic Transmitters and Receivers

Your Network. Our Connection. 10 Gigabit Ethernet

1-Port R422/485 Serial PCIe Card

SFP Copper Transceiver 10/100/1000Base-T

Cisco Small Form-Factor Pluggable Modules for Gigabit Ethernet Applications

DS1307ZN. 64 x 8 Serial Real-Time Clock

Fiber Optics. Integrated Photo Detector Receiver for Plastic Fiber Plastic Connector Housing SFH551/1-1 SFH551/1-1V

it4036f 120-ps Wideband Phase Delay Description Features Device Diagram Timing Diagram

Wideband Driver Amplifiers

CISCO DWDM XENPAK. Main features of the Cisco DWDM XENPAK include:

RS - SPM. Serial parallel translator module

DS1621 Digital Thermometer and Thermostat

HDO700 P FIBRE OPTIC TRANSMITTER

DS1621 Digital Thermometer and Thermostat

Cisco MFE and MGE SFP Transceivers Cisco Small Business Network Accessories

Trends In Data Rate And Link Length In Evolving Optical Standards

HDMM01 V1.0. Dual-axis Magnetic Sensor Module With I 2 C Interface FEATURES. Signal Path X

Rack mounted telephone- and leased line modem for industrial applications

Features. Dimensions

Exceeds all SONET/SDH jitter specifications. Loss-of-lock indicator

28V, 2A Buck Constant Current Switching Regulator for White LED

Dispersion penalty test 1550 Serial

Features. Dimensions

VS-500 Voltage Controlled SAW Oscillator

Direct Attach Cable with Micro Coaxial Wire for Data Center

Features. Dimensions

FEATURES DESCRIPTION APPLICATIONS BLOCK DIAGRAM. PT2248 Infrared Remote Control Transmitter

Signal Types and Terminations

DRM compatible RF Tuner Unit DRT1

ULC Technology: High-performance gate array package using multiple metal layer CMOS technology featuring sub-micron channel lengths (0.

PCI Express: The Evolution to 8.0 GT/s. Navraj Nandra, Director of Marketing Mixed-Signal and Analog IP, Synopsys

Memory Module Specifications KVR667D2D4F5/4G. 4GB 512M x 72-Bit PC CL5 ECC 240-Pin FBDIMM DESCRIPTION SPECIFICATIONS

NS-205-IP67 5-Port Industrial 10/100 Mbps Ethernet Switch with IP67 Casing

11. High-Speed Differential Interfaces in Cyclone II Devices

EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014

DVI Extender via 4 fiber channel LC Duplex Connector Extends DVI connection up to 500 meters

ADQYF1A08. DDR2-1066G(CL6) 240-Pin O.C. U-DIMM 1GB (128M x 64-bits)

Transcription:

Features Supports 9.95Gb/s to 11.1Gb/s bit rates Hot-pluggable XFP footprint Maximum link length of 80km with SMF APD ROSA receiver XFP MSA package with duplex LC connector No reference clock required Compatible with RoHS +3.3V power supply Power dissipation <1.5W Built-in digital diagnostic functions Temperature range 0 C to 70 C XFP Optical Receiver, 80km Reach Applications SDH STM I-64.1 at 9.953Gbps 10GBASE-ZR/ZW 10G Ethernet 10G Fibre Channel 10GE over G.709 at 11.09Gbps OC192 over FEC at 10.709Gbps Other optical links, up to 11.1Gbps Description Gigalight GX-R192-ZRC is compliant with the 10G Small Form-Factor Pluggable (XFP) Multi-Source Agreement (MSA), supporting data-rate of 10.3125Gbps(10GBASE-ZR) or 9.953Gbps 10GBASE-ZW), and transmission distance up to 80km on SMF. The receiver module only use a APD photodiode. Work temperature range of 0 to +70 and offers optimum heat dissipation and excellent electromagnetic shielding thus enabling high port densities for 10 GbE systems. Page 1 of 8

Absolute Maximum Ratings Parameter Symbol Min Max Unit Ref. Storage Ambient Temperature Range -40 +85 Powered case Temperature Range 0 +75 Operating Relative Humidity RH 80 % Supply Voltage Range @ 3.3V Vcc3-0.5 4.0 V Any stress beyond the maximum ratings can result in permanent damage. The device specifications are guaranteed only under the recommended operating conditions. Electrical Characteristics Parameter Symbol Min Typ Max Unit Note Operating Case Temperature Range Tc 0 +70 Power Supply Voltage @ 3.3V Vcc3 3.13 3.3 3.47 V Module total power P 1.5 W Receiver Differential data output swing Vout,pp 500 850 mv Data output rise time t r 38 ps 2 Data output fall time t f 38 ps 2 LOS Fault V LOS fault Vcc - 0.5 Vcc HOST V 3 LOS Normal V LOS norm +0.5 V 3 Power Supply Rejection PSR See Note 3 below 4 Notes: 1. After internal AC coupling. 2. 20 80 % 3. Loss Of Signal is open collector to be pulled up with a 4.7k 10kohm resistor to 3.15 3.6V. Logic 0 indicates normal operation; logic 1 indicates no signal detected. 4. Per Section 2.7.1. in the XFP MSA Specification. Page 2 of 8

Optical Characteristics Parameter Symbol Min Typ Max Unit Ref. Receiver Receiver Sensitivity RSENS -24 dbm 2 Receiver Sensitivity in OMA RSENS -23 dbm 2 Maximum Input Power PMAX -7 dbm Optical Center Wavelength λc 1528 1564 nm LOS De-Assert LOS D -27 dbm LOS Assert LOS A -34 dbm LOS Hysteresis 0.5 db Notes: 1, PRBS 2 31-1 test pattern @10.3125Gbps. 2, PRBS 2 31-1 test pattern @10.3125Gbps, BER 10-12. Pin Descriptions Pin Logic Symbol Name/Description Ref 1 Module Ground 1 2 VEE5 Optional 5.2 Power Supply Not required 3 LVTTL-I Mod-Desel 4 LVTTL-O Interrupt Module De-select; When held low allows the module to, respond to 2-wire serial interface commands Interrupt (bar); Indicates presence of an important condition which can be read over the serial 2-wire interface 2 5 LVTTL-I TX_DIS Transmitter Disable; Transmitter laser source turned off 6 VCC5 +5 Power Supply Not required 7 Module Ground 1 8 VCC3 +3.3V Power Supply 9 VCC3 +3.3V Power Supply 10 LVTTL-I SCL Serial 2-wire interface clock 2 11 LVTTL- I/O SDA Serial 2-wire interface data line 2 12 LVTTL-O Mod_Abs Module Absent; Indicates module is not present. Grounded in the module. 2 13 LVTTL-O Mod_NR Module Not Ready; 2 14 LVTTL-O RX_LOS Receiver Loss of Signal indicator 2 15 Module Ground 1 16 Module Ground 1 17 CML-O RD- Receiver inverted data output Page 3 of 8

18 CML-O RD+ Receiver non-inverted data output 19 Module Ground 1 20 VCC2 +1.8V Power Supply Not required 21 LVTTL-I P_Down/R ST Power Down; When high, places the module in the low power stand-by mode and on the falling edge of P_Down initiates a module reset Reset; The falling edge initiates a complete reset of the module including the 2-wire serial interface, equivalent to a power cycle. 22 VCC2 +1.8V Power Supply Not required 23 Module Ground 1 24 PECL-I RefCLK+ Reference Clock non-inverted input, AC coupled on the host board Not required 25 PECL-I RefCLK- Reference Clock inverted input, AC coupled on the host board Not required 3 26 Module Ground 1 27 Module Ground 1 28 CML-I TD- Transmitter inverted data input 29 CML-I TD+ Transmitter non-inverted data input 30 Module Ground 1 Notes: 1. Module circuit ground is isolated from module chassis ground within the module. 2. Open collector; should be pulled up with 4.7k 10k ohms on host board to a voltage between 3.15Vand 3.6V. 3. A Reference Clock input is not required. 3 Page 4 of 8

Hostboard Connector Pinout TOWARD ASIC 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 VCC2 P-DOWN VCC2 RD- RD+ REFCLK+ REFCLK- TD- TD+ RX_LOS MOD_NR MOD_ABS SDA SCL VCC3 VCC3 VCC5 TX_DIS INTERRUPT MOD_DESEL VEE5 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 TOWARD BEZEL General Specifications Parameter Symbol Min Typ Max Units Ref. Bit Rate BR 9.95 11.1 Gb/s 1 Bit Error Ratio BER 10-12 2 Max. Supported Link Length L MAX 80 km 1 Notes: 1. SONET OC-192 SR-1,SDH STM I-64.1,10GBASE-LR/LW, 1200-SM-LL-L 2. Tested with a 2 31 1 PRBS Page 5 of 8

Management Interface The transceivers provide serial ID memory contents and diagnostic information about the present operating conditions by the 2-wire serial interface (SCL, SDA). The Module provides diagnostic information about the present operating conditions. The transceiver generates this diagnostic data by digitization of internal analog signals. Alarm/warning threshold data is written during device manufacture. Received power monitoring, transmitted power monitoring, bias current monitoring, supply voltage monitoring and temperature monitoring all are implemented. The digital diagnostic memory map specific data field defines as following. Page 6 of 8

Recommended Host Board Power Supply Circuit Host+5V 4.7µH HOST Board VCC5 0.1µf 22µf 0.1µf Host+3.3V Host+1.8V 4.7µH 0.1µf 22µf 4.7µH 0.1µf 22µf VCC3 VCC2 XFP Connector XFP Module Optional Host -5.2V 4.7µH 4.7µH VEE5 0.1µf 22µf Recommended High-speed Interface Circuit Page 7 of 8

Mechanical Specifications XFP transceivers are compliant with the dimensions defined by the XFP Multi-Sourcing Agreement (MSA). Page 8 of 8