Element D Services Plumbing



Similar documents
Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

Element D Services Plumbing

77 ILLINOIS ADMINISTRATIVE CODE, PART 890 (NEW) ILLINOIS PLUMBING CODE (02/04) SUBPART I: WATER SUPPLY AND DISTRIBUTION

One of the fundamental design elements that every

Arapahoe County Residential Water Heater Installation and Inspection Guide

Plumbing Installations. A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

Plumbing Code Sections For Commercial Food Facilities

Plumbing Installations A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

What to Expect From the Examination. How to Study the Plumbing Codes

2010 Residential Water Heater Replacement Check List

Plumbing Code in Commercial Kitchens

PLUMBING & CROSS-CONNECTION CONTROL

PLAN REVIEW SERVICES CONSTRUCTION DOCUMENTS NECESSARY FOR A THOROUGH PLAN REVIEW

LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459

Backflow Bulletin #1

DESIGN CHECKLIST PROJECT NAME DISCIPLINE DATE TYPE REVIEW REVIEWER DRAWINGS REVIEWED

DIVISION 22 PLUMBING PLUMBING EQUIPMENT Domestic Water Heaters

Fire Pump Plan Review March 2010

PLAN REVIEW AND APPROVAL FOR FOOD ESTABLISHMENTS PLUMBING REQUIREMENTS FOR FOOD ESTABLISHMENT PREMISES

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PLUMBING SPECIALTIES

Residential Plumbing BCN 1058

15430 SAFETY SHOWERS AND EYEWASHES

(a) Purpose. The purpose is to safeguard potable water supplies by preventing backflow into public water systems.

Plumbing Code in Commercial Kitchens. NH BOA May 9, 2012

ARTICLE 1141 Cross Connection Control Program

WELCOME INTERNATIONAL RESIDENTIAL CODE 2009 EDITION PLUMBING SECTION

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

Amendments to the 2012 International Plumbing Code

When Should Examination Preparation Begin?

FIRING RANGE PHASE 1 DESIGN

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL Purpose:

2012 BIM Guidelines and Standards (Rev. 00) University at Albany

Revised April (May) 2015

WHITE PLAINS PLUMBING CODE PART 1. GENERAL REQUIREMENTS

PLUMBING ROUGH IN INSPECTION

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

SAM HOUSTON STATE UNIVERSITY

PLAN CHECK CORRECTION SHEET FOR PLUMBING SYSTEMS 2014 LAPC

A. Accessible Fixture: Emergency plumbing fixture that can be approached, entered, and used by people with disabilities.

WESTFIELD WATER RESOURCES DEPARTMENT

Building Permit Application

DIVISION 22 PLUMBING PLUMBING EQUIPMENT Domestic Water Heaters

City of Oviedo Commercial Shell Building Permit Application Guidelines

Oil and Coolant Circulating Heating System. Model - OCSM

FAQ and Device/Usage Chart. What Is a Cross-Connection? What Is Backflow Prevention? What Is Backflow?

TANKLESS WATER HEATER INSTALLATION DIAGRAMS

REGISTRATION EXAMINATION, JUNE 2009 PLUMBING QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Land Use and Environmental Service Agency (Code Enforcement) NC Plumbing Code. Table of Contents

Top 10+ Mistakes of DWV plumbing design

CITY of LOS ANGELES DEPARTMENT of BUILDING and SAFETY

Refrigeration Installation 101

STANDARD PLUMBING AND DRAINAGE REGULATION 2003

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

PIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT

CHAPTER 26 PLUMBING CODE

Plumbing Apprenticeship Program Curriculum

CyberFortress Data Center at Innovation Park Infrastructure and Topology Guide. Innovation Park Charlotte. NC DRAFT V0.

8 plumbing. plumbing PulteGroup, Inc. All Rights Reserved.

Element D Services Heating, Ventilating, and Air Conditioning

SECTION 5 - COMMERCIAL CONSTRUCTION MECHANICAL, ELECTRICAL, PLUMBING AND SOLAR OTHER TECHNICAL CODES

Mechanical, Plumbing, and Fire Protection Conditions

INSTALLATION, OPERATING AND SERVICE INSTRUCTIONS

Winnipeg Fire Department Fire Prevention Branch

Brian Coppock, Regional Compliance Officer. Office of Statewide Health Planning and Development Facilities Development Division

SECTION COMMERCIAL PLUMBING FIXTURES

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

EFFECTIVE FEBRUARY note: drainage permit required to call for a dampproof inspection

NYC Department of Education Building Condition Assessment Survey BROADWAY EDUCATION CAMPUS - MANHATTAN, 26 BROADWAY, MANHATTAN, NY, 10004

BUILDING SAFETY UNIT

SINKS / DISHMACHINES. Food Preparation Sink

Codes and High Performance Hot Water Systems. Gary Klein Affiliated International Management, LLC

A. Accessible Fixture: Emergency plumbing fixture that can be approached, entered, and used by people with disabilities.

ALBERTA FIRE CODE SAFETY EQUIPMENT MAINTENANCE REQUIREMENTS

ONE AND TWO FAMILY DWELLINGS Plumbing July, 2007

DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS

2006 Codes. Please verify the following before calling for inspection

INDIRECT WATER HEATER. Installation and Operating Instruction Manual

Montgomery County Health Department Mobile Food Guidelines. Definitions

New or Remodeled Food Service Establishment Checklist**

Chapter 7 Plumbing Connections

Does Wall Township require an inspection by the building department on resale of a home?

How To Make A House Safe

FILLING AND PURGING THE SYSTEM

12. Design of plumbing systems for single dwellings

2. What building projects are exempted? (permit not required)

Plumbing. Helpful Hints Residential Construction. Lincoln County. Bert Polk Plumbing Inspector

City of Elk River BASEMENT Office Use Only

FOOD ESTABLISHMENT GUIDE FOR DESIGN, INSTALLATION, AND CONSTRUCTION RECOMMENDATIONS

GOLD Plus 30/40/60/80

Fats, Oil and Grease. Best Management Practices Manual. Information, Pollution Prevention, and Compliance Information For Food Service Facilities

TARRANT COUNTY PUBLIC HEALTH DEPARTMENT fax FOOD ESTABLISHMENT REVIEW APPLICATION

FACILITY POTABLE WATER STORAGE TANKS

General Information on Starting a Restaurant Business in Alabama

Job Ready Assessment Blueprint. Plumbing. Test Code: 3061 / Version: 01

Maintaining Fire Protection Systems

SECTION MORTUARY REFRIGERATORS

CHAPTER 5 WATER HEATERS

SECTION TESTING, ADJUSTING, AND BALANCING FOR HVAC INTRODUCTORY INFORMATION

Transcription:

PART 1 - GENERAL 1.01 OVERVIEW A. This section addresses domestic cold, hot and hot water return distribution systems within and to five feet beyond building perimeter. PART 2 - DESIGN CRITERIA 2.01 GENERAL A. Domestic water shall be provided for all plumbing fixtures, food service fixtures and equipment, and all other systems, equipment, and devices that require domestic water supply. B. Building domestic water distribution systems shall be metered and isolated from the municipal water supply in accordance with the municipality s requirements. C. The design of building supply and distribution systems shall provide a volume of water at the required flows, pressures and temperatures to ensure safe, efficient and code compliant operation during periods of peak demand. Piping shall be sized at a velocity not exceeding six feet per second (fps) for cold and hot water and four fps for hot water return. D. Main distribution piping risers shall utilize chases within the building footprint for vertical routing to multiple floor levels where possible. Accessible shut-off valves shall be provided at the base of each riser and at each branch connection to risers. E. Do not locate water piping within stairways, electrical or telecommunications rooms. F. Interior cold water piping shall be insulated to prevent condensation. Interior hot water piping shall be insulated as required by code and per latest ASHRAE Standard A90.1 Table 7.2.3. G. Provide water softener systems to reduce hardness as required to supply food service equipment, water heating equipment, pure water production equipment, and other systems, fixtures and equipment which hard water may adversely affect operation or longevity. Water with a hardness of more than two grains per gallon shall not be delivered to equipment requiring softened water. H. Provide freeze-proof wall hydrants on exterior walls a maximum of 150 feet apart, at loading docks, near building entrances, at mechanical yard and within 50 feet of exterior grease interceptors. Hydrants should be located at approximately 18 inches above finished grade. Coordinate the location of all wall hydrants with the architectural features of the building and obtain approval of locations from the Project Architect. I. Provide freeze-proof wall hydrant on at least one exterior wall of the roof penthouse for maintenance use. ODG030210 1 OF 6

J. Provide a hose bibb with backflow preventer and a minimum of one floor drain in each mechanical room. K. Provide manufactured water hammer arrestors in water supply lines in accordance with Standard PDI-WH201. L. Provide accessible check valves in the individual cold and hot water fixture supply lines serving mixing valve type faucets or assemblies having hose connection outlets that are not equipped with integral check stops. M. Provide line shut-off valves at locations required for proper operation, servicing and troubleshooting of the domestic water distribution system and connected components. Locations shall include but not be limited to the following; at each fixture and piece of equipment, at each branch take-off from mains, at the base of each riser, at each battery of fixtures, where recommended by equipment manufacturers and at strategic locations to allow sectional isolation while limiting disruption of services to large portions of the system. N. Accessible capped valves shall be provided where required for future connections. O. All valves shall be accessible for operation and servicing. Provide access panels for all concealed valves. Coordinate the location of access panels with the architectural features of the building and obtain approval of locations from the Project Architect. P. Trap Priming devices that rely upon line pressure differential for activation are not allowed. Each electronic trap primer device shall be provided with a readily serviceable strainer immediately upstream of the device solenoid valve. 2.02 SYSTEM PRESSURES A. Lower building levels may utilize municipal water system to a height allowed by verified available minimum pressure but shall not serve areas exceeding thirty feet above street grade elevation. B. Static pressure shall be limited to 55 psig (preferred), 80 psig (maximum), on each floor level by accessible pressure regulating valves. Pressure regulating valves shall not be required for municipal pressurized system unless necessary for proper operation of individual equipment. C. Pressure reducing valves shall be duplexed full-size where located within domestic water lines serving in-patient areas, critical research areas, and/or any area or equipment where un-interruptible (24 hour) water service is required. D. Provide isolation valve, strainer and pressure gauge immediately upstream of each pressure regulating valve. Provide pressure gauge and isolation valve immediately downstream of each pressure regulating valve. E. Design of pressure regulating assemblies shall incorporate prevention of over pressurization of downstream piping in the event of valve malfunction. Utilize pressure relief valves only where maximum flow discharge can be evacuated without causing water damage. Automatic solenoid shut-off valves may be provided in lieu of relief valves where approved by Owner. ODG030210 2 OF 6

Automatic shut-off valves shall be connected to the building automation system to annunciate activation. 2.03 PRESSURE BOOSTING SYSTEMS A. Where municipal system pressure is inadequate, a packaged domestic water booster pump system shall elevate the incoming water pressure as required to serve fixtures and equipment. Selection of pumping system type shall be based upon flow and pressure demand, efficiency of operation, life expectancy and maintenance requirements of the equipment. B. Specify variable frequency drives for booster pump systems requiring five horsepower and greater motors and when considered applicable by the A/E and approved by Owner. C. Specify constant speed pressure regulated type booster systems when required pump motors are less than five horsepower and when considered applicable by the A/E and approved by Owner. D. Booster pump systems shall be designed to deliver calculated peak flow at required pressure with one pump out of service. E. Connect booster pump system to emergency power source. 1. Exceptions: Office buildings or where the Owner does not consider this a requirement. F. Booster pumps installed within the City of Houston shall draw water from a domestic break tank provided in accordance with City of Houston requirements. Domestic tank may be combined with fire pump water storage if deemed practical. The domestic surge tank coating shall be NSF approved for potable water and sized based upon available incoming water flow rate and pump demand. Domestic water storage shall not be less than twelve hundred gallons and divided into two compartments to prevent disruption of service during maintenance on fill valves, tank coatings, etc. Provide block valves on tank fill lines when tank overflows cannot discharge by gravity onto grade through an exterior wall. Block valves should be normally open and close when energized by tank high water level switch. Electrical power serving tank level control and monitoring shall be from emergency source. 2.04 DOMESTIC HOT WATER SYSTEMS A. Domestic hot water systems shall be designed to reasonably assure an expeditious flow of hot water at all outlets within 10 seconds. Provide pumped circulating systems where required. Electric heat maintenance cable may be utilized only when considered applicable by the A/E and approved by Owner. B. Size hot water return lines by the heat loss method as outlined in the ASHRAE Guide and Data Book, not to exceed 10 degrees F. heat loss. Developed length of branch piping from fixture outlet to circulated mains shall not exceed 20 feet. C. Water heaters installed and utilized for food service areas shall comply with National Sanitation Foundation (NSF) Standard Number 5 and be separate from water heating ODG030210 3 OF 6

equipment and piping serving other areas of the building. Hot water serving food service commercial dishwasher and pot sink shall be 140 degrees F. All other hot water shall be 110 degrees F maximum at outlets. D. Hot water heating equipment serving areas other than food service may be generated by centralized heaters or point-of-use heaters as determined by economics, space requirements and good engineering practices. All hot water shall be 110 degrees F maximum at outlets. E. Where centralized heaters are provided, utilize semi-instantaneous type with steam to hot water or hot water to hot water double wall heat exchangers. Natural gas fired heaters may be provided where natural gas service is readily available and when considered applicable by the A/E and approved by Owner. F. Water heating equipment shall meet latest ASHRAE standard A90.1 Table 7.2.2. G. Provide NSF and ASME compliant pre-pressurized steel thermal expansion tank with membrane on the cold water supply line of all water heating equipment where cold water service contains check valves, pressure reducing valves or backflow preventers. Thermal expansion tanks shall be sized in accordance with manufacturer s published recommendations. 2.05 CONTAMINATION PREVENTION A. Design of domestic water systems shall avoid all cross connections and eliminate the possibility of water contamination. On each water supply line serving a plumbing fixture, item of equipment, or other device which has a water supply discharge outlet below the overflow rim, or where cross contamination may occur, provide an approved vacuum breaker or backflow preventer. Location of vacuum breakers shall prevent any possible backflow through them. B. Backflow preventers shall be duplexed where located within lines serving in-patient areas, critical research areas, and/or any area or equipment where un-interruptible (24 hour) water service is required. C. Backflow preventer test ports shall not be located more than 72 inches above finished floor or permanent platform. D. Pipe relief from backflow preventer indirectly to drain of sufficient size to evacuate maximum flow discharge. E. Vacuum breakers for hose connections in health care or laboratory areas shall not be less than 72 inches above the floor with the following exceptions: 1. Vacuum breakers integral with faucets or equipment; 2. Vacuum breakers for bedpan washer hoses shall not be located less than 60 inches above the floor. ODG030210 4 OF 6

F. Do not install vacuum breakers above ceilings, above equipment, concealed within walls or any location where water leakage can cause damage. G. Vacuum breakers (including vacuum breakers that are integral with faucets) shall not be installed under exhaust hoods or similar locations that may contain toxic fumes or vapors. H. Air chambers, dead-legs, or any other piping arrangement that may allow water to stagnate shall not be allowed within domestic water systems. I. Valves provided for future connections shall not extend more than 24 inches from an active main. J. Where permanently disconnecting domestic water supplies serving fixtures or equipment, remove all associated piping back to active main to avoid stagnation. PART 3 - SPECIAL CONTRACT DOCUMENT REQUIREMENTS 3.01 GENERAL A. All piping and valves shall be located and sized on Contract Drawings. B. Indicate location and size of all valve access panels on floor plans. C. Include a domestic water system distribution schematic indicating information required to clearly illustrate the intent of system design including, but not limited to, supply source, booster pumps, water tanks, hot water heaters, hot water return pumps, piping mains, risers, pressure regulating stations, backflow prevention, main and riser shut-off valves. Calculated flow rates used for system design shall be noted at supply entrance, pumping system discharge, base of risers, hot water return sectional valves and sectional floor valves at risers. Branch piping to fixtures and equipment is not required to be shown on domestic water system distribution schematic provided that it is included within sanitary waste and vent system riser diagrams or individual equipment details. D. Include details on the Contract Drawings to clearly identify installation requirements for all domestic water system components included within the Project, including but not limited to; water storage tanks, water heaters, pressure regulating stations, building water service riser, pumps, master thermostatic mixing valve assemblies, backflow preventers, trap primer units, roof penetrations, floor and wall penetrations. E. Include schedules on the Contract Drawings to clearly identify capacity, size, model, options and other requirements for all domestic water system equipment included within the Project, including but not limited to; booster pumps, hot water return pumps, water heaters, thermal expansion tanks, pressure regulating valves, master thermostatic mixing valve assemblies, water hammer arrestors, backflow preventers. ODG030210 5 OF 6

PART 4 - PRODUCTS 4.01 GENERAL A. Refer to Owner s Master Construction Specifications. These are available on the Owner s Design Guidelines website: http://www2.mdanderson.org/depts/cpm/standards/specs.html B. System design and piping specified for renovation of existing facilities shall be compatible with existing installation. PART 5 - DOCUMENT REVISION HISTORY Issue Date Revision Description Reviser 01-01-07 Initial Adoption of Element Rev. 1 03-02-10 Changed City of Houston to municipality. Paragraph 2.01 B. ; Added requirement for electronic trap primers. Paragraph 2.01 P. ; Included additional requirements for pressure regulators. Paragraphs 2.02 C,D & E. ; Clarified system size parameters for use of VFD booster pump control. Paragraphs 2.03 B, C & D. ; Included additional requirements for backflow and backsiphonage devices. Paragraphs 2.05 C, D, E, F & G. Rev. 2 Rev. 3 Rev. 4 Rev. 5 DOS END OF ELEMENT D2020 ODG030210 6 OF 6