Series 2000 Audit and Calibration Users Guide



Similar documents
CashFlow Programming Module CPM

PN L, Revision B, October Epic 950 TM. Master Programmer User s Guide

Coyote SP - Installation Notes

PIGCHAMP MOBILE. PigCHAMP Knowledge Software. Installation Guide for Mobile Units

BIODEX. ATOMLAB 500/WIPE TEST COUNTER DATA MANAGER SOFTWARE Version 1.10 (and higher). OPERATION MANUAL

Installing the Gerber P2C Plotter USB Driver

SA-9600 Surface Area Software Manual

Table of Contents. 1. Overview Materials Required System Requirements User Mode Installation Instructions..

ROYAL REGISTERLINK USER'S GUIDE

Additional Requirements for ARES-G2 / RSA-G2. One Ethernet 10 Base T/100 Base TX network card required for communication with the instrument.

History of Revisions. Ordering Information

BACKUP UTILITY FOR TIMEFORCE

Data Management Software. CL-S10w. Installation Guide

Cart Interface Installation & Control Board Manual for M38 XP and RX Carts and Legacy M39 Carts

2. PMP New Computer Installation. & Networking Instructions

ROM ACCESS CONTROL USER S MANUAL

Using USB Flash Drives

FrontDesk Installation And Configuration

Installation Guide for Crossroads Software s Traffic Collision Database

Tournament Pairing Program Installation Instructions for Windows 7

USB Driver Installation for Windows XP

BUS-WATCH R1001/R4001 Quick Guide Series

DIAL-UP DATA. User s Guide

UltraSite32 Network Installation Guidelines

Entire Connection Version 4.2.1

Printer Driver Installation Guide

QUICK START GUIDE. SG2 Client - Programming Software SG2 Series Programmable Logic Relay

Section 5: Preparing the Data Analysis Environment

Rapid Assessment Key User Manual

JEROME COMMUNICATIONS SOFTWARE (JCS) INSTALLATION and OPERATION MANUAL V1.02 for Windows XP

User Manual. Thermo Scientific Orion

USB DRIVER INSTALLATION GUIDE

LT1 Tune Kit Quick Start Guide

BioWin Network Installation

SECURITY SYSTEM MANAGEMENT SOFTWARE FOR WINDOWS. Quick Start Instructions

High Impact & Alpha Five: A Mail Merge Guide.

CashFlow STS User Manual. Cashflow STS V4.00. Support & Test Systems for MEI Cashflow Products. MEI Systems Engineering USER MANUAL

AUDITVIEW USER INSTRUCTIONS

The following items are trademarks or registered trademarks of Kaba Mas in the United States and/or other countries. GITCON

Basic Pivot Tables. To begin your pivot table, choose Data, Pivot Table and Pivot Chart Report. 1 of 18

Victoria Combo Remote Control

Productivity Software Features

Interfacing PC ChargePayment Server with Focus

for Windows 7 Laplink Software, Inc. Quick Start Guide h t t p : / / w w w. l a p l i n k. c o m / h e l p MN-LLG-EN-15 (REV.

BioWin Network Installation

Installing S500 Power Monitor Software and LabVIEW Run-time Engine

Installing Your Multifunction to Your Network for the First Time

USB External Hard Disk Drive

Blastmate III and Minimate Plus USB to PC Cable (Part No. 716A3401)

Section 5: Connecting the Laser to Your Computer

Installation Instruction STATISTICA. Concurrent Network License with Borrowing Domain Based Registration

USER MANUAL Detcon Log File Viewer

Oracle Call Center Connectors

CFD-FX Trading platform Software User Guide. May 2006

ProjectWise Explorer V8i User Manual for Subconsultants & Team Members

Table Of Contents. System Monitoring System Monitoring Display...14 Monitoring Zones...15 About Areas (partitions)...15 Area Status Display...

FX-BTCVT Bluetooth Commissioning Converter Commissioning Guide

AUDITVIEW USER INSTRUCTIONS

DriveRight. Fleet Management Software. Getting Started Guide. CarChip. DriveRight. Drivers. Vehicles. Product #8186

DIRECT INTERNET DATA. User s Guide

STATISTICA VERSION 11 CONCURRENT NETWORK LICENSE WITH BORROWING INSTALLATION INSTRUCTIONS

MICROSOFT OFFICE ACCESS NEW FEATURES

Using Remote Web Workplace Version 1.01

BA-1000 Software Package. Version 1.00

Maxtor OneTouch User's Guide

MS830 / MS833 Barcode Reader v1.0 9-December-2014

Upgrade Instructions. View Manager 96 v Software Upgrade

Snow Active Directory Discovery

Title Page. Installation Guide. PowerChute plus Version for Windows 95

X30 Apollo System Upgrading Monitor Software & ECU Firmware

SOLIDWORKS Education Edition Installation Instructions Preparation

Section 5: Installing the Print Driver

STEP 01 Nortel Contivity VPN Client Installation

When upgrading your TAPIT software make sure that all call accounting data has been exported before you begin the installation process.

USB/RS485 Communication Cable Installation

Testo FlashUpdate. Instument Software Update and Download Instructions How to Download Instrument Software and Updates from the Internet

Instructions for Formatting APA Style Papers in Microsoft Word 2010

Loss of data can happen in many ways. One of the most common causes is hard drive failure. Hard drives can die without warning.

Config software for D2 systems USER S MANUAL

S&G Audit Lock. Audit Trail Software Manual

Quick Start Guide. Highly customizable automated trading Automate your trades according to rules and models you create.

DIAL-UP DATA. User s Guide

Gorilla CRM System Installation Instructions

LPR for Windows 95/98/Me/2000/XP TCP/IP Printing User s Guide. Rev. 03 (November, 2001)

USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: Rev 6

Getting Started. rp5800, rp5700 and rp3000 Models

To view your team, including your universal profile, please complete the following steps: Result: Your universal bio page will display.

Quick Start Guide. Digital Inverted Microscope. The Microscope Evolved.

FSU Inventory Scanner Set up & Use for Windows PC

How to Add Users 1. 2.

TECHNICAL BULLETIN. Configuring Wireless Settings in an i-stat 1 Wireless Analyzer


Getting Started with POS. Omni POS Getting Started Manual. switched on accounting

Promethean Trouble Shooting Tips v 2.0. A quick guide for the most common problems

User's Guide DylosLogger Software Version 1.6

Download Software 2.33 For Vigil civil I, II, 2 + & Military II, II+, II+c -

Centran Version 4 Getting Started Guide KABA MAS. Table Of Contents

Diamante WiFi Wireless Communication User Guide. Linksys E1200

Setting up Digi Connect Wi-SP or Digi ConnectPort TS W Devices On a Secured Wireless Network for use with Veriteq viewlinc

Transcription:

Series 2000 Audit and Calibration Users Guide This software tool has been designed to allow operators to calibrate and audit the Series 2000 bill acceptors. The following sections will explain how to use this software and describe the functions. Items Included in the Kit: Software part number 281321100 (1 CD-ROM) Series 2000 MDB/BDS (Gen1 / Gen 2) Harness part number 250072034 (Quantity 1) Calibration Paper part number 111513417P (Quantity 10) Users Guide part number 250057204 System Requirements and Install Instructions: Windows 95 / 98 or higher 1) Insert CD-ROM into the computer 2) Wait for the installation program to start automatically. If it does not start automatically, run setup.exe program in the disk 1 directory of the CD-ROM Windows 3.1 1) Insert the CD-ROM into the computer. 2) Run setup.exe program in disk 1directory of CD-ROM. 2008 MEI Inc. All Rights Reserved. The MEI device, MEI CASHFLOW, MEI EASITRAX and SODECO are registered trademarks of MEI in the U.S. and other countries. Information is subject to change without notice. MEI has made every effort to assure that the information in this document is accurate. However, we cannot be held responsible for any errors or omissions. www.meigroup.com Part # 250057204 Rev. G3 1

Upon installing disk 1, the Welcome Screen will appear. Click the Next button to continue. (See Figure 1) Fig 1 The next screen is a License Agreement Screen. Click Yes on this screen to install the AuditCal software. (See Figure 2) Fig 2 2

The next screen is Choose Destination Location. Click next. See Fig 3 and Fig 4 below. Fig 3 Fig.4 3

When the setup is complete, click Finish. See Fig.5 below. Fig.5 4

Locate auditcal\auditcal.exe on your C: drive. Double click the auditcal\auditcal.exe file to access the AuditCal program. The main screen will appear. (See Figure 6) Main Screen Fig 6 5

1.0 Connecting the Interface Harness Use the enclosed Series 2000 MDB/BDS Harness to establish communications between your computer and the Series 2000 bill acceptor. Begin by plugging the P3 connector (refer to drawing below) into the serial port on your computer, and connect the 30-pin connector to the bill acceptor. Note: There are two 30-pin connectors; one for 24-volt units labeled P6 and one for 115-volt units labeled P1. Below is a chart explaining which power connector to use: Power Connections Vending Machine Tester 24 VAC P-7 P-4 24 V MDB P-4 P-4 115 VAC P-2 P-2 Accessories P-4 MDB Extension Harness- P/N 250071026 P-2 Gaming Interface Harness- P/N 01-12-139 Note: If you are testing the 115V bill acceptor on the bench, use the gaming interface harness to establish power at the P2 connector. 6

2.0 Communications Once the power and communication connectors are in place, turn on the source power. To establish communications, click on the Update button at the top right-hand corner of the main screen. You will see the red bar in the upper left-hand portion of the main screen turn green, and it will read Communication is open. (See main screen below) 3.0 Calibration To calibrate the bill acceptor, click on the Calibrate button at the upper right corner of the main screen. The bill acceptor bezel lights will start flashing quickly. Insert one sheet of calibration paper into the bill acceptor with the green arrows on the calibration paper facing in towards the bill acceptor. Calibration paper will come out in small segments. Once it stops completely, pull the calibration paper out of the bill acceptor. The calibration process is then complete. To print a copy of the data, click the Print button in the upper right hand corner of the main screen. (See Figure 7) Fig 7 7

Summary The Read Rec button allows you to display previously saved audit files. When you click this button, a file selection dialog appears. You can select multiple files by holding down the shift or control key and clicking on the files. Selected files get added into the combo box directly below the clear and remove buttons. You can use the combo box to click down one file at a time or use the scroll bar to view audit file. The Clear box clears the list of files in the combo box. The Remove box allows you to remove files one at a time from the list. You can use this feature to exclude files from the summary when you use the summary feature. After auditing a bill acceptor, you can use the Write Rec button to save the audit information into a file. Note: Separate the audit files according to Model Numbers of the Bill acceptors to be able to use the summary feature. It is recommended that you save your files under AuditandCal/support/audit. To keep it simplified, file them as AE2600, AE2800, Gen1VN25AE24, and GEN2VN25AE24. You could create other directories and organize them, as you desire. If you have audit files saved from different types of validators saved into the same folder and you try to summarize the audit information, you will get an Audit file type mismatch error message. If you get this message you can fix this problem by removing that file from that directory to the appropriate folder. The Key S# allows you to enter a serial number and to look at the audit files from a particular bill acceptor. To use this feature, enter the desired serial number to this box and press Read Rec button and select the audit file. When you press the summary button, the Audit & Cal Tool will summarize the audit files for this validator. The Key Date is to enter and read audit data from a given date to now: The date must be entered in this format: Example 08/19/02. When you press the Summary button, Audit & Cal Tool will summarize all the audit files in the combo box from this date to present. Similarly, you can enter a serial number and key date and summarize audit results for a specific validator from a given date to present. 8

4.0 Audit Data # of Bills Escrowed # of Bills Rejected # of Bills Accepted Selection of the Com Port Identification # of Bill Acceptor Serial # of Bill Acceptor # of Bills Accepted by Denomination # of Bills Stacked by Denomination # of Bills Rejected by Denomination Vending Machine Controller Returns Bills Returned for Other Reasons Combination of Misc. and Disabled Returns Acceptance Rate by Denomination # of Accepted Bills divided by # of Escrowed Bills # of Stacked Bills divided by # of Accepted Bills This section is for adding any comments you have pertaining to the bill acceptor data. Rev. G3 9

4.0 Audit Data Closes Communication to Bill Acceptor Exports a comma separated text file of the Audit information. Downloads New Software into the Bill Acceptor Opens Communications Calibrate a Bill Acceptor Print a Record Allows the audit information to be saved in a file. Note: Separate the audit files according to bill acceptor model numbers. To enable the use of the summary feature, save the files under: audit/cal/support/audit. Create File Folders such as AE2600, AE2800, VN25/AE24 GEN I, and VN25/AE24 Gen II. Remove allows for the removal of individual files from the list. Combo Box - Files that are currently selected for viewing Rev. G3 10

4.0 Audit Data Cash value of bills accepted by the bill acceptor # of Inserted Bills divided by # of Stacked Bills Read Rec box- allows you to display previously saved audit files. You can select multiple files by holding down the shift key and clicking on the files. Selected files get added into the combo box The clear box clears the list of files in the combo box Slider- Lets you scroll through the individual files in the combo box. Enter a serial number to look up and summarize audit files for a particular bill acceptor. Enter a date and look up and summarize audit files for a particular bill acceptor. This will summarise all the audit files in the combo box from the Key Date to present. Note: You can enter a serial number (S#) and Key Date and summarize audit results for a specific bill acceptor. Rev. G3 11

4.0 Audit Data Identifies which bills are enabled Check mark means Enabled Blank means Disabled # of Pulses per dollar Identifies Pulse Type Identifies which option switches are ON. Check mark means ON. Blank means OFF. Credit line - Interface used by some types of machines in vending # of bill directions (1, 2, or 4 way bill acceptance) What interface the Bill Acceptor is in. Which Bills are in High Security or High Acceptance. Check mark means High Security. Blank means High Acceptance. Rev. G3 12