Keysight E5063A ENA Series PCB Analyzer

Similar documents
Agilent E5063A ENA Series Network Analyzer

Agilent E5063A ENA Series Network Analyzer. 100 khz to 4.5/ 8.5/18 GHz

Keysight M9485A PXIe Multiport Vector Network Analyzer. Configuration Guide

Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors. Demo Guide

What is the difference between an equivalent time sampling oscilloscope and a real-time oscilloscope?

Keysight Technologies Understanding and Improving Network Analyzer Dynamic Range. Application Note

Keysight Technologies Connecting Data Acquisition Systems to a Wireless Network

Keysight Technologies Using Fine Resolution to Improve Thermal Images. Application Note

Agilent U2000 Series USB Power Sensors

U7248A High Speed Inter-Chip (HSIC) Electrical Test Software Infiniium Oscilloscopes

Evaluating Oscilloscope Bandwidths for Your Application

TekConnect Adapters. TCA75 TCA-BNC TCA-SMA TCA-N TCA-292MM Data Sheet. Applications. Features & Benefits

How to Measure 5 ns Rise/Fall Time on an RF Pulsed Power Amplifier Using the 8990B Peak Power Analyzer

Keysight Technologies Drive Down the Cost of Test Using the ENA Series of Network Analyzers. Application Note

E5092A Configurable Multiport Test Set

802.11ac Power Measurement and Timing Analysis

Keysight N6854A Geolocation System. Configuration Guide

1.5 GHz Active Probe TAP1500 Datasheet

Agilent BenchVue Software (34840B) Data capture simplified. Click, capture, done. Data Sheet

Make Better RMS Measurements with Your DMM

Agilent 4339B/4349B High Resistance Meters

Agilent E5061B Network Analyzer. 100 khz to 1.5 GHz/3 GHz 5 Hz to 3 GHz

Agilent U2000 Series USB Power Sensors

Revision 1.10 April 7, 2015 Method of Implementation (MOI) for 100BASE-TX Ethernet Cable Tests Using Keysight E5071C ENA Option TDR

Agilent 87421A/87422A Power Supply

Agilent E363xA Series Programmable DC Power Supplies. Data Sheet

The Next Generation in Automated Oscilloscope Test

Agilent FieldFox Remote Viewer

DDR Memory Overview, Development Cycle, and Challenges

Agilent 4338B Milliohm Meter

Agilent P940xA/C Solid State PIN Diode Switches

Agilent U2000 Series USB Power Sensors

X-Series Signal Analysis. Future-ready instruments Consistent measurement framework Broadest set of applications and software

Agilent MATLAB Data Analysis Software Packages for Agilent Oscilloscopes

Time-Correlated Multi-domain RF Analysis with the MSO70000 Series Oscilloscope and SignalVu Software

Variable Frequency Drive Troubleshooting with U1610A/U1620A

AN3353 Application note

Keysight Technologies 8 Hints for Better Spectrum Analysis. Application Note

Keysight Technologies Long-Term, Remote Monitoring of Satellite Performance

High-voltage Differential Probes TMDP THDP THDP P5200A - P5202A - P5205A - P5210A

N5416A and N5417A USB Compliance Test Software for Infiniium Oscilloscopes

Impedance 50 (75 connectors via adapters)

Agilent Test Solutions for Multiport and Balanced Devices

Keysight Technologies Drive Down the Cost of Test Using the ENA Series of Network Analyzers. Application Note

Real-Time Spectrum Analysis for Troubleshooting n/ac WLAN Devices

Keysight Technologies N9320B RF Spectrum Analyzer

Keysight N9320B RF Spectrum Analyzer

Agilent Mobile WiMAX R&D Test Set Solutions: Software and Technical Support Contract

Agilent Electronic Calibration (ECal) Modules for Vector Network Analyzers

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

Testing WiMAX receiver performance in a multipath propagation environment using Agilent s E6651A with an EB Propsim C8 radio channel emulator

Keysight Technologies How to Choose your MAC Lever. Technical Overview

Keysight Technologies Quickly Identify and Characterize Thermal Measurement Points

Agilent Measuring Noninsertable Devices

Agilent E6832A W-CDMA Calibration Application

PCI Express 1.0 (2.5 GT/s) Protocol Test

Agilent N5970A Interactive Functional Test Software: Installation and Getting Started

Keysight Technologies The Advantages Of Remote Labs In Engineering Education

Basics of RF Amplifier Measurements with the E5072A ENA Series Network Analyzer

AC/DC Current Measurement Systems TCPA300, TCP312A, TCP305A, TCP303, TCPA400, TCP404XL Datasheet

Agilent 8762/3/4A,B,C Coaxial Switches

PCI Express Probes for Agilent E2960B PCI Express Analysis Systems

HCF4056B BCD TO 7 SEGMENT DECODER /DRIVER WITH STROBED LATCH FUNCTION

Agilent Compatibility of the U2000 Series USB Power Sensors with Agilent Instruments. Application Note

Agilent Infoline Web Services. Quick Reference Guide. Scan and use your phone to go to Infoline at

LM833 LOW NOISE DUAL OPERATIONAL AMPLIFIER

Agilent Technologies. Troubleshooting Three-Phase AC Motors with U1210 Series Handheld Clamp Meters. Application Note

Advanced Power Measurement and Analysis Software DPOPWR Datasheet

One Port Network Analyzer

An Overview of the Electrical Validation of 10BASE-T, 100BASE-TX, and 1000BASE-T Devices

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

E5061B-3L5 LF-RF Network Analyzer with Option 005 Impedance Analysis Function. Data Sheet

Keysight E2688A, N5384A High-Speed Serial Data Analysis and Clock Recovery Software

iva Cable & Antenna Analyzer

Agilent Television Power Consumption Testing. Application Note

Agilent De-embedding and Embedding S-Parameter Networks Using a Vector Network Analyzer. Application Note

DSL01-xxxSC5. Secondary protection for DSL lines. Features. Description. Applications. Benefits. Complies with the following standards

High-Definition Multimedia Interface (HDMI) Source/Sink Impedance Compliance Test Test Solution Overview Using the E5071C ENA Option TDR

Installation Guide E Dielectric Probe Kit 85071E Materials Measurement Software

Description. Table 1. Device summary. Order code Temperature range Package Packaging Marking

NI USB-6008/6009 OEM USER GUIDE

R&S ZNBT8 Vector Network Analyzer Specifications

ETP01-xx21. Protection for Ethernet lines. Features. Description. Applications. Benefits. Complies with the following standards

Agilent Automotive Power Window Regulator Testing. Application Note

Recommendations for TDR configuration for channel characterization by S-parameters. Pavel Zivny IEEE GCU Singapore, 2011/03 V1.

HCF4081B QUAD 2 INPUT AND GATE

Keysight Technologies Solutions for WLAN ac Manufacturing Test

Foreign Taxes Paid and Foreign Source Income INTECH Global Income Managed Volatility Fund

PCI Express Transmitter PLL Testing A Comparison of Methods. Primer

ESDLIN1524BJ. Transil, transient voltage surge suppressor diode for ESD protection. Features. Description SOD323

PESDxU1UT series. 1. Product profile. Ultra low capacitance ESD protection diode in SOT23 package. 1.1 General description. 1.

High-Speed Inter Connect (HSIC) Solution

N6171A MATLAB Data Analysis Software for Agilent Instruments

Table 1. Absolute maximum ratings (T amb = 25 C) Symbol Parameter Value Unit. ISO C = 330 pf, R = 330 Ω : Contact discharge Air discharge

R&S ZNC Vector Network Analyzer Specifications

CAN bus ESD protection diode

UA741. General-purpose single operational amplifier. Features. Applications. Description. N DIP8 (plastic package)

Utilizing Time Domain (TDR) Test Methods For Maximizing Microwave Board Performance

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

Agilent. E5071C ENA Network Analyzer. E5092A Configurable Multiport Test Set. Data Sheet

Transcription:

Keysight E5063A ENA Series PCB Analyzer Technical Overview The Best Solution for PCB Manufacturing Test More accuracy and R&R More languages supported More ESD robustness

Why choose the E5063A PCB Analyzer for your toughest printed circuit board measurement challenges? As the operating speed of electronic circuits increase, signal integrity of printed circuit boards (PCBs) drastically affect performance and there is an increasing requirement for controlled impedance PCBs. In addition, with the proliferation of wireless devices, such as smartphones and tablets, there is a trend to integrate antennas onto PCBs. Therefore, in addition to the traditional time domain impedance measurement, there is a growing need to measure the frequency domain response of PCB integrated antennas. The E5063A PCB Analyzer consists of a E5063A ENA Series Network Analyzer with Option 011 (Time domain analysis/ Test Wizard). The E5063A provides frequency domain measurement capability and Option 011 adds time domain analysis capability, as well as a dedicated graphical user interface for PCB manufacturing test. The number of available ports can be expanded up to four with the addition of U1810B USB coaxial switches, to allow for simultaneous connection to both single-ended and differential probes. Speed, accuracy and easeof-use you need to ramp up rapidly and optimize PCB manufacturing test. The E5063A PCB Analyzer changes the world of PCB measurements. Key features and beneits Up to 18 GHz of bandwidth with 24.8 ps rise time enables measurement on the latest PCB designs Unmatched performance Wide dynamic range to observe the true performance of your DUT: > 100 db (at 4.5 GHz) Low noise loor for accurate and repeatable measurements: 75 μvrms Fast measurement speed for real-time analysis: 154 msec (at 1601 points with full 2-port calibration performed) State-of-the art error correction techniques reduce measurement errors Automatic deskew ensures easy removal of ixture and probe effects Full calibration (ECal) available for the utmost in measurement accuracy Upgrade all available ENA hardware and software options at any time. Buy what you need today and protect your investment by upgrading later when requirements change. 02

E5063A ENA Series PCB Analyzer The Best Solution for PCB Manufacturing Test Three breakthroughs for PCB manufacturing test Compared to traditional solutions based on TDR Oscilloscopes, the E5063A PCB Analyzer provides: More accuracy and R&R (Repeatability & Reproducibility) More languages supported More ESD robustness More accuracy and R&R Delivers new standards in accuracy Low noise loor for accurate and repeatable measurements State of the art error correction techniques enables you to measure your device, not your measurement system More languages supported An analyzer that speaks the user s language Since there are many cases where tasks are solved more eficiently in one s native language, a multilingual user interface is provided. Currently available languages include English, Simpliied and Traditional Chinese, Japanese, and Korean More ESD robustness Protection circuits implemented inside the instrument Proprietary electrostatic discharge (ESD) protection chip signiicantly increases ESD robustness, while at the same time maintaining excellent RF performance Highly robust architecture can minimize instrument failure from ESD and free you from worrying about instrument repair fees and downtime 03

E5063A ENA Series PCB Analyzer The Best Solution for PCB Manufacturing Test The PCB Analyzer user interface is designed specifically for measuring controlled impedance and return loss on PCBs. Providing a similar look-and-feel to traditional solutions, the PCB Analyzer is easy to setup and use without the need for extensive operator training. Edit Test mode Test files are easily created and modified via the integrated test file editor. Most files can be created with just a few mouse clicks. Test files provide a convenient method for automated testing of boards with a number of different controlled impedance traces. Execute Test mode Simple and intuitive user interface for non-technical operators. All the information necessary for performing measurements is stored in a test file. An operator only needs to select the appropriate test file from a list and the system is ready for testing. 04

E5063A ENA Series PCB Analyzer The Best Solution for PCB Manufacturing Test Wizards Setup and Error Correction Wizards allows for intuitive and error free setup, error correction, and measurements. Dedicated controls for common adjustments The vertical and horizontal scales can be optimized by using the software knobs. In addition, the horizontal units can be set to display either time or distance (English or metric units). The DUT Length Wizard automatically measures the DUT length. The DUT length setting is used to set the optimum time span for measurements. After the time span is set, the test limits can be deined as a percentage of the trace length. Absolute, average, or multi-segment limit types are available. 05

Three Breakthroughs for PCB Manufacturing Test More accuracy and R&R Accurate, repeatable, and reproducible measurements are important to ensure measurement correlation between the OEM and fabricator, as well as increasing yield. If there is no measurement error, one can distinguish between good and bad products with confidence. There are two main considerations: absolute accuracy of measurement and measurement R&R (Repeatability and Reproducibility). A number of factors can influence accuracy and R&R: cables, fixtures and probes, test equipment and operators. Error correction is a powerful technique to remove systematic errors due to the cables, fixtures and probes, and test equipment. If there is measurement error, one may be left in doubt about the acceptability of the product. State of the art error correction techniques reduce measurement errors and allows the PCB Analyzer to deliver new standards in accuracy required for the latest generation of products. Guard bands are often used to account for measurement error, but results in lower yield. 06

Three Breakthroughs for PCB Manufacturing Test Error correction Error Correction Techniques Most accurate Accuracy Full Calibration (SOLT) Full Calibration (ECal) Deskew and loss compensation Deskew (port extension) Level of Difficulty Easiest Choose your level of accuracy tradeoff between complexity and accuracy Over the years, many different approaches have been developed for removing the effects of the test fixture and probes from the measurement. The level of difficulty for each error correction technique is related to the accuracy of each method. It is important to have a test system that will allow flexibility of choosing the method of error correction desired for each application. Deskew (also known as Port Extension) mathematically extends the calibration reference plane to the DUT, effectively removing the delay from the test setup. This technique is easy to use, but assumes the probe and ixture the unwanted structure looks like a perfect transmission line: a lat magnitude response, a linear phase response, and constant impedance. If the probe and ixture are very well designed, this technique can provide good results. Deskew and loss compensation mathematically extends the calibration reference plane to the DUT, effectively removing the delay and loss from the test setup. This technique is a good compromise between level of dificulty and accuracy. Full calibration (SOLT) is one of the most comprehensive calibrations. This calibration effectively removes delay, loss, and mismatch from the test setup, making it possible to perform measurements with the highest possible accuracy. Electronic calibration (Ecal) is a complete solid-state calibration solution which makes full calibration fast and easy. Traditional mechanical calibrations require intensive operator interaction which is prone to errors. With ECal, the operator simply connects the ECal module to the instrument and the software controls the rest. 07

Three Breakthroughs for PCB Manufacturing Test More languages supported Since there are many cases where tasks are solved more efficiently in one s native language, a multi-lingual user interface is provided. Currently available languages include English, Simplified and Traditional Chinese, Japanese, and Korean. More ESD robustness In applications such as PCB testing, large static charges can be stored in the DUT. Special care is required when using traditional instruments in such situations, to make sure that the instrument is not damaged by electrostatic discharge (ESD). Vulnerability to ESD can lead to increased maintenance fees and long repair times. The E5063A PCB Analyzer is designed for high robustness against ESD by implementing protection circuits inside the instrument. Leveraging the company s expertise in RF design, Keysight Technologies, Inc. has invested in key technology blocks like our proprietary ESD protection chip to significantly increase ESD robustness, while at the same time maintaining excellent RF performance. ESD survival IEC 801-2 Human Body Model. (150 pf, 330 Ω) RF Output Center pins tested to 3 kv, 10 cycles 08

Key Speciications Deinitions Speciication (spec.): Warranted performance. All speciications apply at 23 C (± 5 C), unless otherwise stated, and 90 minutes after the instrument has been turned on. Speciications include guard bands to account for the expected statistical performance distribution, measurement uncertainties, and changes in performance due to environmental conditions. Typical (typ.): Expected performance of an average unit which does not include guardbands. It is not covered by the product warranty. General characteristics (char.): A general, descriptive term that does not imply a level of performance. Test set option Option 2H5 Option 285 Option 245 Bandwidth spec. 18 GHz 8.5 GHz 4.5 GHz Input connector char. Type-N (female) Input impedance char. 50 Ω nominal Maximum non-destruct voltage typ. ± 35 VDC TDR stimulus 1 char. Step TDR step rise time spec. 24.8 ps 52.4 ps 99.1 ps (10% to 90%) (min) 2 TDR step response resolution in free char. 7.4 mm 15.8 mm 29.7 mm space (εr = 1) (min) 3 TDR deskew range spec. 50 ns (Test Cable Length) (max) 4 DUT length (max) 5 spec. 1.25 µs TDR stimulus repetition rate (max) spec. 18 MHz 8.5 MHz 4.5 MHz RMS noise level 6 typ. 75 µvrms 1. The time domain function of the PCB Analyzer is similar to the time domain reflectometry (TDR) measurement on a TDR oscilloscope in that it displays the response in the time domain. In the TDR oscilloscope measurement, a pulse or step stimulus is input to the DUT and the change of the reflected wave over time is measured. In the PCB Analyzer measurement, a sine wave stimulus is input to the DUT and the change of the reflected wave over frequency is measured. Then, the frequency domain response is transformed to the time domain using the inverse Fourier transform. 2. Minimum values may be limited by the DUT length setting. 3. To convert from rise time to response resolution, multiply the rise time by c, the speed of light in free space. To calculate the actual physical length, multiply this value in free space by vf, the relative velocity of propagation in the transmission medium. Most cables have a relative velocity of 0.66 for a polyethylene dielectric or 0.7 for a PTFE dielectric. 4. Using high quality cables and probes to connect to the DUT is recommended in order to minimize measurement degradation. The cables should have low loss, low reflections, and minimum performance variation when flexed. 5. Maximum DUT length is the sum of the DUT and test cable lengths. To convert from DUT length in seconds to distance in free space, multiply the value in time by c, the speed of light in free space. To calculate the actual physical length, multiply this value in free space by vf, the relative velocity of propagation in the transmission medium. Most cables have a relative velocity of 0.66 for a polyethylene dielectric or 0.7 for a PTFE dielectric. 6. RMS noise level with 50 Ω DUT and default setup. For more details, refer to the E5063A ENA Series Network Analyzer datasheet http://literature.cdn.keysight.com/litweb/pdf/5991-3615en.pdf 09

Ordering Information Step 1: Select frequency range Option E5063A-245 E5063A-285 E5063A-2H5 Description 2-port test set, 100 khz to 4.5 GHz 2-port test set, 100 khz to 8.5 GHz 2-port test set, 100 khz to 18 GHz Step 2: Choose additional option (mandatory) Option E5063A-011 Description Time Domain Analysis/Test Wizard Step 3: Choose accessories (optional) Product U1810B 85092C 85093C N4690C N4691B N4431B N4432A N4433A Description USB Coaxial Switch, DC to 18 GHz, SPDT ECal module, 2-port, 300 khz to 9 GHz, Type-N ECal module, 2-port, 300 khz to 9 GHz, 3.5 mm ECal module, 2-port, 300 khz to 18 GHz, Type-N ECal module, 2-port, 300 khz to 26.5 GHz, 3.5 mm ECal module, 4-port, 300 khz to 13.5 GHz, 3.5 mm or Type-N ECal module, 4-port, 300 khz to 18 GHz, Type-N ECal module, 4-port, 300 khz to 20 GHz, 3.5 mm Upgrade Options Option E5063AU-285 E5063AU-2H5 E5063AU-2H6 E5063AU-011 Description Upgrade from 4.5 GHz to 8.5 GHz Upgrade from 4.5 GHz to 18 GHz Upgrade from 8.5 GHz to 18 GHz Time Domain Analysis/Test Wizard 10

Typical System Coniguration Single-ended and differential probing, 18 GHz system (any third party TDR passive probe can be used with the PCB Analyzer) Qty Option/product Description 1 E5063A-2H5 2-port test set, 100 khz to 18 GHz 1 E5063A-011 Time Domain Analysis/Test Wizard 1 U1810B USB coaxial switch, DC to 18 GHz, SPDT 1 N4433A ECal module, 300 khz to 20 GHz, 3.5 mm, 4-port For more details, refer to the E5063A ENA Series Network Analyzer configuration guide http://literature.cdn.keysight.com/litweb/pdf/5991-3616en.pdf Web Resources E5063A ENA Series PCB Analyzer www.keysight.com/find/ena-pcb ENA Series Network Analyzers www.keysight.com/find/ena ENA Series Service and Support www.keysight.com/find/ena_support Electronic Calibration (ECal) Modules www.keysight.com/find/ecal Related Literature E5063A ENA Series Network Analyzer Brochure http://literature.cdn.keysight.com/litweb/pdf/5991-3614en.pdf E5063A ENA Series Network Analyzer Data Sheet http://literature.cdn.keysight.com/litweb/pdf/5991-3615en.pdf E5063A ENA Series Network Analyzer Configuration Guide http://literature.cdn.keysight.com/litweb/pdf/5991-3616en.pdf Network Analyzer Selection Guide http://literature.cdn.keysight.com/litweb/pdf/5989-7603en.pdf 11

012 Keysight E5063A ENA Series PCB Analyzer - Technical Overview mykeysight www.keysight.com/find/mykeysight A personalized view into the information most relevant to you. www.lxistandard.org LAN extensions for Instruments puts the power of Ethernet and the Web inside your test systems. Keysight is a founding member of the LXI consortium. Three-Year Warranty www.keysight.com/find/threeyearwarranty Keysight s commitment to superior product quality and lower total cost of ownership. The only test and measurement company with three-year warranty standard on all instruments, worldwide. Keysight Assurance Plans www.keysight.com/find/assuranceplans Up to five years of protection and no budgetary surprises to ensure your instruments are operating to specification so you can rely on accurate measurements. www.keysight.com/quality Keysight Technologies, Inc. DEKRA Certified ISO 9001:2008 Quality Management System Keysight Channel Partners www.keysight.com/find/channelpartners Get the best of both worlds: Keysight s measurement expertise and product breadth, combined with channel partner convenience. For more information on Keysight Technologies products, applications or services, please contact your local Keysight office. The complete list is available at: www.keysight.com/find/contactus Americas Canada (877) 894 4414 Brazil 55 11 3351 7010 Mexico 001 800 254 2440 United States (800) 829 4444 Asia Paciic Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 112 929 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Other AP Countries (65) 6375 8100 Europe & Middle East Austria 0800 001122 Belgium 0800 58580 Finland 0800 523252 France 0805 980333 Germany 0800 6270999 Ireland 1800 832700 Israel 1 809 343051 Italy 800 599100 Luxembourg +32 800 58580 Netherlands 0800 0233200 Russia 8800 5009286 Spain 0800 000154 Sweden 0200 882255 Switzerland 0800 805353 Opt. 1 (DE) Opt. 2 (FR) Opt. 3 (IT) United Kingdom 0800 0260637 For other unlisted countries: www.keysight.com/find/contactus (BP-07-10-14) This information is subject to change without notice. Keysight Technologies, 2013-2014 Published in USA, August 4, 2014 5991-3617EN www.keysight.com