Quantum Scalar 50 Tape Drive Installation Instructions



Similar documents
Cascade Profiler Fibre Channel SAN Attached Storage Installation Guide. Version 8.2 March 2009

HP StorageWorks 8Gb Simple SAN Connection Kit quick start instructions

SuperLoader 3. Quick Start Guide. Installing the Autoloader 0

White Paper. Quantum StorageCare Guardian

HP ProLiant DL380 G5 High Availability Storage Server

: HP HP Version : R6.1

Implementing IBM Tape in Linux and Windows

actitape LTO-3 and LTO-4 internal SCSI and SAS Quick Start Guide

NI InsightCM Server Version 1.0

HP StorageWorks MSL2024, MSL4048, and MSL8096 Tape Libraries Ultrium 3280 Fibre Channel tape drive firmware release notes

Direct Attached Storage

System Overview and Terms

If you are unable to set up your Linksys Router by using one of the above options, use the steps below to manually configure your router.

Before You Begin You must have at least the following: Web Browser Wired Hub/Switch/Router OR Wireless b Router CD-ROM Drive

Deploying SAP on Microsoft SQL Server 2008 Environments Using the Hitachi Virtual Storage Platform

How to Install a Business Internet Video Camera

To view this information... Installing additional tape drives page 5 Replacing a tape drive with the same configuration

HP R12000 and R18000 DirectFlow UPS User Guide

Express5800/120Ed. Rack Mount Kit Installation Procedures PN:

HP StorageWorks Modular Smart Array 1000 Small Business SAN Kit Hardware and Software Demonstration

Infinity C Reference Guide

Avigilon Control Center 5 System Integration Guide. Video and Event Viewer for Lenel OnGuard

Adding or replacing a mesh node in an existing mesh network

eprism Security Suite

Application Note. Configuring a NEO Tape Library with Symantec Backup Exec and NetApp NDMP Environment. Technical Bulletin. November 2013.

Aolynk DR814Q ADSL2+ Broadband Router Quick Start

About This Guide SolarEdge Configuration Tool Software Guide. About This Guide

SAN Conceptual and Design Basics

19 LCD / 8 CHANNEL DVR COMBO WITH 160GB HDD & 4 CAMERAS

Cisco TelePresence VCR MSE 8220

Quick Start Guide. Cisco Small Business. 200E Series Advanced Smart Switches

DPS Telecom Your Partners in Network Alarm Management

HP LaserJet MFP Analog Fax Accessory 300 Fax Guide

HP StorageWorks MSL2024, MSL4048, and MSL8096 Tape Libraries firmware release notes. Firmware version 4.60 (MSL2024), 6.90 (MSL4048), 9.

Best Practices for Troubleshooting Superloader3

QuickSpecs. HP StorageWorks Direct Backup Engine for Tape Libraries. Extended Tape Library Architecture (ETLA) Family. Models.

: HP HP0-X02. : Designing & Implementing HP Enterprise Backup Solutions. Version : R6.1

Rebasoft Auditor Quick Start Guide

Network Monitoring User Guide Pulse Appliance

capacity management for StorageWorks NAS servers

Dell SupportAssist Version 2.0 for Dell OpenManage Essentials Quick Start Guide

Quick Start Guide. Cisco Small Business. 300 Series Managed Switches

Integrated Virtualization Manager ESCALA REFERENCE 86 A1 82FA 01

Quick Setup Guide RAID Array 8000/ESA12000 Fibre Channel Storage Subsystem for Hewlett Packard HP-UX

RSA Security Analytics. S4 Broker Setup Guide

GV-Data Capture V3 Series User's Manual

HP PolyServe Software upgrade guide

Updating Tape Drive Firmware

Job Aid: Replacing the Hard Drive on the Avaya S8710 Media Servers R2.2 or Later

AgGPS 542 Receiver: Enable GLONASS through the Web Browser

HP VMware ESXi 5.0 and Updates Getting Started Guide

AXIS Camera Station Quick Installation Guide

Quick Start Guide. RV0xx Series Routers

vrealize Operations Manager Customization and Administration Guide

HP Converged Infrastructure Solutions

Metasys System Direct Connection and Dial-Up Connection Application Note

Intel Active Management Technology with System Defense Feature Quick Start Guide

Setup Guide. An installation space and network environment must be prepared in advance.

P-660R-T1 v3 QUICK START GUIDE. ADSL2+ Access Router DEFAULT LOGIN DETAILS. Firmware v3.40 Edition 1, 09/2008. IP Address:

Prestige 650R-31/33 Read Me First

Intel Unite Solution. Standalone User Guide

Setting Up the ZigBee Ethernet Gateway

Installing Windows 95 Drivers and Utilities for the Cisco Aironet 340/350 Series Client Adapters

REMOTE ACCESS DDNS CONFIGURATION MANUAL

VoIP Intercom with Allworx 6x Server Setup Guide

PART 1 CONFIGURATION 1.1 Installing Dashboard Software Dashboardxxx.exe Administration Rights Prerequisite Wizard

EMC ViPR Controller. User Interface Virtual Data Center Configuration Guide. Version REV 01

Quick Start Guide. Cisco Small Business. 200 Series 8-Port Smart Switches

Projetex 9 Workstation Setup Quick Start Guide 2012 Advanced International Translations

VinNOW/TSYS Integration Setup. Overview

2100 Series VoIP Phone

CA Unified Infrastructure Management Server

Configuring Sun StorageTek SL500 tape library for Amanda Enterprise backup software

Prestige 314 Read Me First

Wireless G Broadband quick install

HP 36-Port InfiniBand Switch Cable Management Kit Installation Guide

Installing Sage ACT! 2013 for New Users

Installation Notes for Outpost Network Security (ONS) version 3.2

FlexArray Virtualization

ilan Ethernet Box for 9100 Installation Manual

Access control designed simply for you

D-Link DAP-1360 Repeater Mode Configuration

VERITAS Backup Exec 9.1 for Windows Servers Quick Installation Guide

Quick Start Guide. WAP371 Wireless AC/N Dual Radio Access Point with Single Point Setup Quick Start Guide. Cisco Small Business

Brocade Network Advisor: CLI Configuration Manager

TIBCO Spotfire Automation Services 6.5. Installation and Deployment Manual

Choosing the best architecture for data protection in your Storage Area Network

SolarWinds Migrating SolarWinds NPM Technical Reference

StorSimple Appliance Quick Start Guide

RouteFinder SOHO. Quick Start Guide. SOHO Security Appliance. EDGE Models RF825-E, RF825-E-AP CDMA Models RF825-C-Nx, RF825-C-Nx-AP

HP StorageWorks Enterprise Backup Solution design guide

Moxa Device Manager 2.0 User s Guide

Ethernet Radio Configuration Guide

IBM BladeCenter H with Cisco VFrame Software A Comparison with HP Virtual Connect

IBM System Storage. N3300 Installation and Setup Instructions

1 Modular System Dual SCM MPIO Software Installation

IIS, FTP Server and Windows

Package Contents. D-Link DSN-3200/3400 Installation Guide. DSN-3200/3400 xstack Storage Area Network (SAN) Array. CD-ROM with User Guide.

Transcription:

Quantum Scalar 50 Tape Drive Installation Instructions Introduction 3 Tape Drive Numbering... 3 Scalar 50 Tape Drive Upgrade Kits... 4 Required Tools... 6 Unpacking the Tape Drive 6 Installing the Tape Drives 6 Cabling the Tape Drives 7 Setting the Tape Drive SCSI ID 10 Setting the SCSI ID Using the OCP... 11 Setting the SCSI ID from the Remote Management Pages... 12 Completing the Native Fibre Channel Installation 15 Determining the WWNs World Wide Names... 15 Verifying Library Connectivity... 18 Fibre Channel Connectivity Troubleshooting 20 Fibre Channel Connectivity Troubleshooting... 20 SCSI ID Assignment with Native Fibre Channel Tape Drives... 22, 1

Made in the USA. Quantum Corporation provides this publication as is without warranty of any kind, either express or implied, including but not limited to the implied warranties of merchantability or fitness for a particular purpose. Quantum Corporation may revise this publication from time to time without notice. COPYRIGHT STATEMENT Copyright 2008 by Quantum Corporation. All rights reserved. Your right to copy this document is limited by copyright law. Making copies or adaptations without prior written authorization of Quantum Corporation is prohibited by law and constitutes a punishable violation of the law. TRADEMARK STATEMENT Capacity on Demand (CoD), Crosslink Mechanism, DLT, DLTSage, DLTtape, Super DLTtape, Performance on Demand, (PoD), PRISM, PRISM Storage Architecture logo, SiteCare, StackLink, StorageCare, SuperLoader, and ValueLoader are all trademarks of Quantum Corporation. Quantum, the Quantum logo, and the DLTtape logo are all registered trademarks of Quantum Corporation. Other trademarks may be mentioned herein which belong to other companies. 2

Introduction 0 This document provides instructions for adding a tape drive to an Scalar 50 tape library. The tape drive upgrade procedure consists of the following steps: Half-height tape drive canisters are ONLY available in Scalar 50 tape libraries. Unpacking the Tape Drive Installing the Tape Drives Cabling the Tape Drives Setting the Tape Drive SCSI ID Completing the Native Fibre Channel Installation Fibre Channel Connectivity Troubleshooting Tape Drive Numbering 0 The Scalar 50 tape library may contain up to 4 tape drives depending on the tape drive type. Refer to the following figures: Figure 1 Full height drives (up to two per library) Figure 2 Half-height drives (up to four per library) Figure 1 Scalar 50 Cable Configuration (Full Height Drives) Tape drive 2 Tape drive 1 Back of Library Introduction 3

Figure 2 Scalar 50 Cable Configuration (Half-Height Drives) Tape drives 3 and 4 Tape drives 1 and 2 Back of Library Scalar 50 Tape Drive Upgrade Kits 0 The tape drive upgrade kit differs depending on the tape drive type needed for the library. Refer to the following tables: Table 1 for SDLT tape drives kits Table 2 for LTO tape drive kits Table 1 Tape Drive Upgrade Kits (SDLT) SDLT Part Number PC-UUAQA-YF (DLT-S4, SCSI) PC-UU8QC-YF (DLT-S4, Native Fibre) DLT-S4 Tape Drive Module 4 Introduction

Table 2 Tape Drive Upgrade Kits (LTO) LTO Part Number PC-KUCQA-YF (LTO-3 HH SCSI, single drive) PC-KUC1A-YF (LTO-3 HH SCSI, dual drive) PC-KUKQC-YF (LTO-3 HH Native Fibre, single drive) PC-KUKQ1-YF (LTO-3 HH Native Fibre, dual drive) PR-UU3QA-YF (HP LTO-3, SCSI) PR-UU5QC-YF (HP LTO-3, Native Fibre) PC-KUMQA-YF (HP LTO-4, SCSI) PC-KUNQH-YF (HP LTO-4 HH SAS, single drive) PC-KUN1H-YF (HP LTO-4 HH SAS, dual drive) PC-KUGQC-YF (HP LTO-4, Native Fibre) HP-LTO2/3/4 Tape Drive Module LTO-3/4 Half- Height Tape Drive Module (Single Drive) LTO-3 Half- Height Tape Drive Module (Dual Drive) Introduction 5

Required Tools 0 The following tools are required to perform the tape drive upgrade procedure: Flat blade screwdriver Caution: Use appropriate electrostatic discharge (ESD) precautions when installing the tape drive. Unpacking the Tape Drive 0 To unpack the tape drive: 1 Open the shipping carton. 2 Remove the tape drive from the carton. The tape drive is protected by two pieces of foam and an antistatic bag. 3 Remove the foam from the wrapped tape drive. Remove the tape drive from the antistatic bag. Installing the Tape Drives 0 To install tape drives in a Scalar 50 Series library: If this is an initial library installation, it is recommended to turn the library off prior to installing tape drives. If this is an existing library that is receiving a tape drive upgrade, the library can remain powered on. Each tape drive ships from Quantum with a version of library firmware as well as drive firmware on the tape drive interface PWA. When you install the tape drive, the library will check the version of library firmware on the tape drive and verify if the firmware is newer than the version currently running. If the library firmware on the tape drive is newer than the version currently running on the library, the OCP will prompt you with the option to upgrade the library firmware. 1 At the back of the library, use a flat blade screwdriver to loosen the captive screws that secure the cover plate to the empty drive bay. 2 Set the cover plate aside. 6 Unpacking the Tape Drive

3 Insert the tape drive into the drive bay slowly until the connectors are seated (see figure 3). 4 Tighten the tape drive captive screws using a flat blade screwdriver. 5 Repeat steps 1 through 4 to install another tape drive in a different location, if desired. Figure 3 Installing a Tape Drive Tape drive 1 Captive screw Tape drive 2 Captive screw Proceed to Cabling the Tape Drives. Cabling the Tape Drives 0 After the tape drive(s) have been installed, you must connect SCSI, SAS or Fibre Channel cables to each drive. Refer to the following figures to cable the tape drives: Figure 4 SCSI full height drives Figure 5 Native Fibre Channel full height drives Figure 6 SCSI half-height drives Figure 7 SAS half-height drives (Surrogate mode SCB only) Figure 8 Native Fibre Channel half- height drives Figure 9 Stacked Library Configuration Cabling the Tape Drives 7

Figure 4 Scalar 50 Cable Configuration (SCSI Full Height Drives) Ethernet SCSI host System Controller Board Tape drive 2 Tape drive 1 Power Back of Library Figure 5 Scalar 50 Cable Configuration (Native Fibre Channel Full Height Drives) Ethernet Fibre Channel host/san Back of Library Tape drive 2 Tape drive 1 LTO Tape drives shown. SDLT drives have a single FC port Power Fibre Channel host/san Fibre Channel host/san Figure 6 Scalar 50 Cable Configuration (SCSI Half- Height Drives) Ethernet SCSI host SCSI System Controller Board Back of Library Terminator Tape drives 3 and 4 Tape drives 1 and 2 Power SCSI host SCSI host Terminator SCSI host 8 Cabling the Tape Drives

Figure 7 Scalar 50 Cable Configuration (SAS Half- Height Drives) Ethernet Surrogate Mode System Controller Board ONLY Back of Library Tape drives 3 and 4 Tape drives 1 and 2 Power SAS hosts SAS hosts Figure 8 Scalar 50 Cable Configuration (Native Fibre Channel Half-Height Drives) Ethernet Fibre Channel host/san Back of Library Tape drives 3 and 4 Tape drives 1 and 2 Power Fibre Channel host/san Fibre Channel host/san Cabling the Tape Drives 9

Figure 9 Scalar 50 Cable Configuration (Stacked) Scalar 50 (slave library) Tape drive 2 Tape drive 1 Host computer Host computer Scalar 50 (master library) Tape drive 2 Tape drive 1 Host computer Setting the Tape Drive SCSI ID 0 The next step in the installation procedure is to set the required SCSI ID for the new tape drive. The library assigns SCSI IDs based on the drive order. Drive bay 1 = SCSI ID 1, drive bay 2 = SCSI ID 2, and so forth. It is only necessary to perform the steps in this section if you need to set the tape drive SCSI ID to an ID other than the default. SAS tape drives to not require a SCSI ID. Use the default tape drive configuration for SAS tape drives. 10 Setting the Tape Drive SCSI ID

There are two ways to set the tape drive SCSI ID: Setting the SCSI ID Using the OCP Setting the SCSI ID from the Remote Management Pages Setting the SCSI ID Using the OCP 0 To set the tape drive SCSI ID on an Scalar 50 Series library with an LCD: 1 From the operator control panel (OCP), press Setup from the Home screen. The OCP displays the Setup screen (see figure 10): Figure 10 Setup Screen Enter 2 Use the up and down arrows to highlight Cabinet and press Enter. The Cabinet screen displays (see figure 11): Figure 11 Library Options Screen 3 Use the up and down arrows to highlight Host bus and press Enter. The Host bus screen displays (see figure 12): SAS tape drives do not require a SCSI ID and cannot be configured. Used the default tape drive configuration information. Surrogate control is set via the Partition page on the remote management pages. Setting the Tape Drive SCSI ID 11

Figure 12 Host Bus Options Screen 4 Use the up and down arrows to highlight the tape drive receiving the new SCSI ID and press Enter. 5 Use the up and down arrows to select a SCSI ID and press Enter to set the ID. 6 When you have completed setting the SCSI IDs, press Exit to return to the Cabinet screen. 7 From the Ops screen, use the up and down arrows to highlight Drive Operations and press Enter. The Drive Operations screen displays (see figure 13): Figure 13 Drive Operations Screen 8 Use the up and down arrows to select a tape drive and press Enter. 9 Use the up and down arrows to select Off and press Enter. The tape drive powers down and returns to the Drive Operations screen. 10 Use the up and down arrows to select On and press Enter. The tape drive powers on and is ready for use. The tape drive installation is complete. Setting the SCSI ID from the Remote Management Pages 0 To set the tape drive SCSI ID on a Scalar 50 Series library from the remote management pages: The library must be off-line during this procedure. 1 On the host computer, open the internet browser software. 2 In the Address field, type http://ipaddress/ where IP address is the IP address for the Quantum Scalar 50 Series library. 12 Setting the Tape Drive SCSI ID

3 Enter the username and password and click OK. The default username and password is admin. The Overview page displays (see figure 14): Figure 14 Overview Page Banner area Quick status Navigation area Content area 4 Click the Setup tab. The Setup tab displays. 5 Click on the SCSI tab at the top of the Setup tab. The SCSI page displays (see figure 15). Figure 15 SCSI Page Setting the Tape Drive SCSI ID 13

6 To change a SCSI ID, enter the ID number in the field next to the device and click Apply. SAS tape drives do not require a SCSI ID and cannot be configured. Use the default tape drive configuration information. 7 From the Operations page, click on the Drives tab. The Drives page displays (see figure 16): Figure 16 Drives Page Drive operations 8 Enter the new tape drive number 9 Select shutdown and click Apply. The tape drive powers down. 10 Enter the new tape drive number 11 Select Power on and click Apply. The tape drive powers on. The tape drive installation is complete. The firmware revision on the new tape drive(s) must match the firmware revision on the currently installed tape drives (of the same tape drive type). If the new tape drive has a different revision, you must download the appropriate tape drive firmware from Quantum and update the drive. All tape drives in the library must contain the same firmware revision. You can view the tape drive firmware revision on the OCP under Drive Operations. 14 Setting the Tape Drive SCSI ID

Completing the Native Fibre Channel Installation 0 After native Fibre Channel tape drives are installed, additional information must be gathered to complete the installation and verify connectivity. Competing the native Fibre Channel tape drive installation consists of the following steps: Determining the WWNs World Wide Names Verifying Library Connectivity Determining the WWNs World Wide Names 0 The media changer (robot) and tape drives within the library have WWNs World Wide Names assigned to them by the system controller board (SCB). The WWNs must be determined and recorded both for the customer and for Quantum customer support. This information is important when replacing the Fibre Channel SCB and tape drives. Using the following procedures, complete table 3 and retain a copy of the table for your records. Have this table available when contacting Quantum Customer Support for any library or tape drive connectivity issues. Table 3 Library World Wide Names Library/Tape Drive World Wide Name (e.g. 50:05:08:40:00:16:47:00) Media Changer (robot) Tape drive 1 Tape drive 2 Tape drive 3 Tape drive 4 Using the Remote Management to Determine the WWNs 0 To determine the WWNs from the library remote management pages: 1 On the host computer, open the internet browser software. 2 In the Address field, type http://ipaddress/ where IP address is the IP address for the Quantum Scalar 50 series library. 3 Enter the username and password and click OK. The default username and password is admin. The Overview page displays (see figure 17): Completing the Native Fibre Channel Installation 15

Figure 17 Overview Page 4 Click Setup from the contents frame. The management frame displays the Setup page (see figure 18). Figure 18 Setup Page 5 Click on the SCSI/Fibre tab. The SCSI/Fibre page displays (see figure 19). 16 Completing the Native Fibre Channel Installation

Figure 19 SCSI/Fibre Page Media changer Tape drives Connectivity type 6 For the Media Changer and Tape Drives, click Fibre under the Connectivity type. The Media Changer (see figure 20) and Tape Drive Configuration (see figure 21) screen displays. Figure 20 Media Changer Configuration Screen World wide name Completing the Native Fibre Channel Installation 17

Figure 21 Tape Drive Configuration Screen World wide names (port 0 and port 1) 7 Record the WWNs for the media changer and tape drives in table 3. These numbers are the world wide NODE names for the library and tape drives. The World Wide Port Name is very similar to the World Wide Node Name, however, the last hex byte is 01h greater than the last hex byte of the node name. Repeat step 6 for all tape drives in the library or Add 04h to the last hex byte to derive the WWN for the next tape drive. Example: Drive 0 WWN is 50:05:08:40:16:6B:00, Drive 1 WWN will be 50:05:08:40:16:6B:04, Drive 2 WWN will be 50:05:08:40:16:6B:08. 8 To determine the WWN for the media changer, subtract 01h from the next to last hex byte of the WWN for Drive 0. Example: Drive 0 WWN is 50:05:08:40:16:6B:00, Media Changer WWN will be 50:05:08:40:16:6A:00. Verifying Library Connectivity 0 To verify the tape drive installation, you should verify that the library and tape drives are recognized from the host or from the SAN switch. If the SAN switch is available, it is possible to verify connectivity by connecting to the switch. There are two ways to directly access the SAN switch: Connect Via a Telnet Session 18 Completing the Native Fibre Channel Installation

Connect Via a Web Browser The information below applies to a Brocade SAN switch. For other SAN switches, contact the SAN administrator. Connect Via a Telnet Session 0 To connect via a Telnet session to a SAN switch: 1 Connect the service laptop to the SAN switch using an Ethernet crossover cable, or by connecting to the LAN (if available). 2 On the service laptop, open a command prompt window. 3 From the command prompt, enter the following command and press <Enter>: telnet <IP address of SAN switch> The SAN switch login prompt displays. 4 Enter the username and password and press <Enter>. For Brocade SAN switches, the default login is admin for the username and password for password. This may have been changed by the system administrator. For all other switches, contact the system administrator. 5 For Brocade switches, at the command prompt, type nsshow and press <Enter>. The nsshow command displays (see figure 22). Figure 22 Nsshow Command WWN for the library WWN for the second Native Fibre channel drive WWN for the first Native Fibre channel drive Completing the Native Fibre Channel Installation 19

If the world wide names are visible from the nsshow command, the connectivity is verified. Connect Via a Web Browser 0 To connect via a web browser: 1 Connect the service laptop to the SAN switch using an Ethernet crossover cable. 2 On the service laptop, launch a web browser such as Internet Explorer. 3 In the Address field, type http://ipaddress/ where IP address is the IP address for the SAN switch and press <Enter>. The SAN switch web based utility displays. 4 Examine the Name Server table for the status of the switch ports and the WWNs of the connected devices. If the WWNs for the library and all tape drives are visible, the connectivity is verified. Fibre Channel Connectivity Troubleshooting 0 Refer to the following sections Fibre Channel connectivity troubleshooting: Fibre Channel Connectivity Troubleshooting SCSI ID Assignment with Native Fibre Channel Tape Drives Fibre Channel Connectivity Troubleshooting 0 The following section provides Fibre Channel connectivity problems and resolutions when connecting via Fibre Channel to the SAN switch, or directly to the library and drives. 1 Medium changer and drives are not visible in the device manager a Check all cable connections. b c Check the SAN switch port LEDs for connection status to the library Fibre Channel HBA and tape drives. If you are connected to the SAN switch, verify that you are connected to the same zone as the library and tape drives. If you are unsure, try one of the ports on the SAN switch that a tape drive is connected to. If you are not on a port in the same zone as the library and all of the drives, you will not be able to verify connectivity. d Verify that the SAN switch is powered on and operating normally. 20 Fibre Channel Connectivity Troubleshooting

e If you are still unable to view the Fibre Channel devices, launch the SANsurfer SANblade manager and click Connect. Accept the default localhost entry. The SANblade manager displays (see figure 23). Figure 23 SANblade Manager The SANblade manager should display all connected Fibre Channel devices. If the library and tape drives do NOT display, check the cabling and connection status. Fibre Channel Connectivity Troubleshooting 21

SCSI ID Assignment with Native Fibre Channel Tape Drives 0 With native Fibre Channel tape drives, each tape drive is it s own Fibre Channel target with a dedicated WWN and on LUN 0. The host (including the laptop using MAGMA box) will pick up the devices and assign local SCSI IDs in the order that the SAN devices are discovered. This will in almost every case NOT match the order of the devices as they are installed in the library. This is not a problem from the customer point of view, as long as drive serialization is enabled on the library and serialization is supported by the customers ISV application. This will allow the ISV application to put the drives in the correct order within the application. In some rare cases it may be necessary to re-map the local SCSI ID assignments so that the library changer is at SCSI ID 0 and the drive SCSI ID assignments follow in order. The important thing to remember is that the order of the SCSI IDs on your system will probably not match the order of the drives in the library. Make sure to check the SCSI ID that is assigned to the WWN of the drive you want to communicate with or you may be communicating to the wrong drive 22 Fibre Channel Connectivity Troubleshooting

To display the SCSI ID assignments: 1 From the SANblade manager program, click Configure. The port configuration screen displays (see figure 24). Figure 24 Port Configuration Screen SCSI ID assignment The port configuration screen allows you to change the SCSI ID order if the Fibre Channel HBA drive supports persistent bindings. Click on the drop down ID box to change the SCSI ID assignment as desired. Fibre Channel Connectivity Troubleshooting 23

*81-81769-02 A01* 81-81769-02 A01 24 Fibre Channel Connectivity Troubleshooting