BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets

Similar documents
INSTALLATION INSTRUCTIONS SENSOR OPERATED LAVATORY FAUCET. EBF-85 and EBF-187 Battery Powered, Sensor Operated Lavatory Faucet

SENSOR FAUCETS. OPTIMA ETF-80 Faucet. P a r t s G u i d e 24 VAC HARDWIRE FAUCETS SLOAN VALVE COMPANY SEYMOUR AVENUE FRANKLIN PARK, IL 60131

Installation Instructions

MAC FAUCETS. Owner s Manual. Models: FA444

INSTALLATION INSTRUCTIONS FOR ELECTRONIC SENSOR ACTIVATED HAND WASHING FAUCET

G2 Optima Plus Flushometer

Installation Instructions S

HYDROTEK INTERNATIONAL, INC Forsyth Commerce Rd., Ste. 124, Orlando, FL Phone (800) / Fax (866)

Installation Instructions

Installation Instructions / Warranty

Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer

Installation Instructions

USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2

CW-4622 INSTALLATION INSTRUCTIONS CB-4622 RISER KIT TO SUIT BLACK LEVER EXPOSED VALVES & BATH/SHOWER VALVES

INSTALLATION INSTRUCTIONS BL-8704

Version: 1.0 TWO HANDLES INWALL WATERFALL FAUCET INSTALL GUIDE

INSTALLATION INSTRUCTIONS MK-8704

Electronic faucets for every occasion, every application

Select Radiators Installation Guide

INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

BATHROOM FAUCET ITEM # MODEL # H2. Francias / Español p. 9 ATTACH YOUR RECEIPT HERE

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters.

Installation Instructions

Electronic Wallmount Faucet 1500T4 & 1501T4 Series

Installation Instructions / Warranty

Pre-Fab Easy Installation For Models: 006-CT-USK, 008-CT-USK Installation and Operating Instructions for Existing Homes with Standard Piping

STAINLESS STEEL TANK TABLE OF CONTENTS TROUBLESHOOTING... 1 TESTING WATER TEMPERATURE... 3 TANK & JACKET ASSEMBLY... 4.

Installation Instructions / Warranty

Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)

FAUCET SPECIFICATIONS. Vessel Bathroom Faucet Model VG03023 MODEL VG03023

Hot, Warm and Cold Mineral Water Cooler [Models Cool18, Cool25, Cool36, Cool50, Cool75, Cool100]

Installation and Operation Manual

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

UNIT 7: PLUMBING KEY CONCEPTS. 1. Identify tools for plumbing. 2. Location of shutoff valves for the main and individual fixtures

SURGICAL SCRUB SINKS INSTALATION-OPERATION-MAINTENANCE USER MANUAL

HYDROTEK INTERNATIONAL, INC.

Installation guide Nordic mixer taps. Before installing read this guide first

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

Fixtures - Parts - Accessories to shampoo bowls

OPERATING INSTRUCTIONS. Shortening Filter Model No. 99-A, 102-A, & 107-A Series LIMITED WARRANTY PRODUCT SPECIFICATION

MODEL VG08008 CONTENT PACKING LIST / TOOLS NEEDED PANEL DIMENSIONS FITTINGS / TECHNICAL DATA WALL/CORNER INSTALLATION CARE AND TROUBLE SHOOTING

B150 Series Commercial Brewer. Direct Plumb Kit

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

Line to Refrigerator Ice/Water Dispenser

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

Fleck Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Fuel Injection Pump, Rotary ( )

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Solstice/Sky Water Pump Replacement

TOLL FREE: (866) VANITY SPECIFICATIONS. VANITY COMPONENTS Model VG09042K1

Watts Pure Water Systems

OWNER S MANUAL. FOOTWORKS tm Faucet Controller. Foot Operated Faucet Control Valves for Commercial Sinks

Assembly and instructions

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

Installation Instructions

PArt# spout Length Adjusts /2 to 8-1/ /2 to 8-1/ /2 to 8-1/ /2 to 8-1/2. PArt# FIts Adjusts

STABITHERM INSTALLATION & SERVICE BOOKLET

INSTANT HOT WATER RECIRCULATING SYSTEM

Geyser-R Heat pump water heater Installation manual

Sealant. 30" Model No D: 17-7/8" TO 18-3/8" (454 to 466mm) W: 29-3/4" TO 30-1/4" (756 to 768mm) Under Countertop Installation

Fiberstars Lighted Laminar Flow Fountain Installation Manual

A3650/11LMWS (Metal Lever) A3650/11LPWS (Porcelain Lever)

Before repairing your toilet, you must determine

TWO-WAY DIVERTER WITH THREE-WAY HAND SHOWER

TS93 EMR T/PT/TDE. Surface applied door closer

Operator s Manual. Pressure Injection Cell Model PC8500. Congratulations! Contents

Installation Operation Maintenance Troubleshooting Version 2.1, Apr/09 DAYTONA

Instruction Manual. Image of SP-3015 & SP Important Safeguards. Automatic Dispensing Hot Water Pot with Reboil Function

Cleaning & Sanitisation

Utility Distribution Systems

Hommage 2 PIECE WATER CLOSET BOWL MODEL TANK MODEL 7721 U1 SEAT MODEL

KLE-115U Single Rack Undercounter Configuration Instruction Manual

Section 7 Adjustment, Repair and Replacement

Polaris 9300 & 9400 Series Robotic Cleaner

How To Fix A Car With A Carbide Engine

How To Replace A Reverse Osmosis Water Tank

PRODUCT: WASHER / WASHER-DRYER COMBO MODEL: AW 120 / AW 122 / AW 125 AWD 120 / AWD 121 / AWD 129

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

Equipped with AEM Dryflow Filter No Oil Required! INSTALLATION INSTRUCTIONS PART NUMBER DS BMW 335i 3.0L

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat

! WARNING. Before using product, read and understand instructions.

Folding Bath Screen Instruction Manual

Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW

Global Water Instrumentation, Inc.

Thermostatic Valve Replacement Cartridge and Rebuild Kit

SALEEN SPEEDLAB SERIES VI STANDARD SC UPGRADE KIT

Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual

FLUSHMATE FLUSHMATE FLUSHOMETER - TANK SYSTEM. Owner s Service Manual 503 and 504 Series

SERVICE MANUAL RESIDENTIAL ELECTRIC AND LIGHT DUTY COMMERCIAL ELECTRIC WATER HEATERS. Troubleshooting Guide and Instructions for Service

THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494

8 plumbing. plumbing PulteGroup, Inc. All Rights Reserved.

Coolflo Safe Touch Shower Mixing Valve ST20015CP

GE SmartWater INSTALLATION INSTRUCTIONS. Heavy Duty Water Filtration System GNWH38F SAFETY PRECAUTIONS PROPER INSTALLATION

Providing Temperature. Regulated Warm Water. to your Sanicare. Hand Spray Bidet

VOYAGER 570G. 744A Sprayer Control


OPERATION GUIDE. IMPORTANT NOTE: For more information see our instructional video online at model no.

Transcription:

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets Any Application. Any Environment. Code No: 0816407 Rev. 4 (07/12) EFX-6XX Integrated Base, Sensor Activated Lavatory Faucets MODEL GUIDE EFX 0. 1. 0 0 Body Type Power Crown. Mix Sensing Flow Rate. Batteries Base Plate Adapters 0 Hardwire Standard. None 0.5 gpm Multi-Lam. Alkaline None None No 1. 2. Mechanical, Below Deck Thermostatic, Below Deck Drain Pop- Up Capacitance. 4-inch Plug-in (US) 1.5 gpm Aerated + Laminar. 8-inch 3 Pedestal.. 4.. 5 Battery.. 6 Integrated Base.. 7.. 8 Turbine.. Base Plates are not intended for the integrated base models. LIMITED WARRANTY Unless otherwise noted, Sloan Valve Company warrants this product, manufactured and sold for commercial or industrial uses, to be free from defects in material and workmanship for a period of three (3) years (1 year for SF faucets, special finish and PWT electronics and 30 days on PWT software) from date of first purchase. During this period, Sloan Valve Company will, at its option, repair, replace, or refund the purchase price of any product which fails to conform with this warranty under normal use and service. This shall be the sole and exclusive remedy under this warranty. Products must be returned to Sloan Valve Company, at customer s cost. No claims will be allowed for labor, transportation or other costs. This warranty extends only to persons or organizations who purchase Sloan Valve Company s products directly from Sloan Valve Company for purpose of resale. This warranty does not cover the life of the battery. THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. IN NO EVENT IS SLOAN VALVE COMPANY RESPONSIBLE FOR ANY CONSEQUENTIAL DAMAGES OF ANY MEASURE WHATSOEVER. PRIOR TO INSTALLATION Prior to installing the Sloan BASYS Series Faucets, install the items listed below. Also, refer to rough-in illustrations. IMPORTANT: ALL PLUMBING SHOULD BE INSTALLED IN ACCORDANCE WITH APPLICABLE CODES AND REGULATIONS. FLUSH ALL WATER LINES PRIOR TO MAKING CONNECTIONS. KEEP THREAD SEALANT OUT OF YOUR WATERWAY TO PREVENT COMPONENT PART DAMAGE! DO NOT USE ANY SEALANT ON COMPRESSION FITTINGS. Base Plates When the BASYS Faucet is installed on a sink that has three (3) hole punchings, a trim plate should be used. Base Plates should be specified at the time of ordering. EFX-20-A 4 (102 mm) Centerset Sinks EFX-26-A 8 (203 mm) Centerset Sinks IMPORTANT Not for installation on a metal sink or deck (i.e. stainless steel or cast metal).

TOOLS REQUIRED FOR INSTALLATION 13 mm open end wrench or nut driver for faucet retainer nut 2.5 mm hex allen wrench 5/8 open end wrench for female end of flex hose FAUCET ROUGH-IN 6.25 (159 mm) 2 (51 mm) 4 (106 mm) 5 (126 mm) 2 (47.5 mm) 42 2.5 (63 mm) 1.25 (31 mm) 5.7 (147 mm) 6 (152 mm) 2 (51 mm) 4 (106 mm) 5 (124 mm) 2 (46 mm) 42 2.5 (63 mm) 1.25 (31 mm) 2.25 (57 mm) 2

FAUCET ROUGH-IN (CONTINUED) EFX-3X0.X1X.0000 WITH HOT/COLD WATER SUPPLY SPOUT EFX-3X0.01X.0100 WITH TEMPERED WATER SUPPLY AND 4-INCH BASE PLATE SPOUT EFX-6X0.X1X.0000 WITH HOT/COLD WATER SUPPLY SPOUT 1-3/16 (30 mm) MIN. DIA. REQUIRED BASE PLATE 1-3/16 (30 mm) MIN. DIA. REQUIRED 1-3/16 (30 mm) MIN. DIA. REQUIRED MOUNTING HARDWARE MOUNTING HARDWARE MOUNTING HARDWARE OPTIONAL ADAPTER CONTROL MODULE OPTIONAL ADAPTER CONTROL MODULE OPTIONAL ADAPTER CONTROL MODULE 3/8 (10 mm) SUPPLY TUBE (BY OTHERS) BELOW DECK THERMOSTATIC MIXING VALVE TEMPERED SUPPLY 3/8 (10 mm) SUPPLY TUBE (BY OTHERS) BELOW DECK THERMOSTATIC MIXING VALVE HOT SUPPLY BELOW DECK MECHANICAL MIXING VALVE SHOWN INSTALLED COLD SUPPLY 3/8 (10 mm) COMPRESSION STOPS (BY OTHERS) HOT SUPPLY BELOW DECK MECHANICAL MIXING VALVE SHOWN INSTALLED COLD SUPPLY 3/8 (10 mm) COMPRESSION STOPS (BY OTHERS) 3/8 (10 mm) COMPRESSION STOPS (BY OTHERS) IMPORTANT Not for installation on a metal sink or deck (i.e. stainless steel or cast metal). EFX Faucets are available with a 0.5 gpm (1.9 Lpm) multi-laminar spray, 1.5 gpm (5.7 Lpm) aerated stream, and 1.5 gpm (5.7 Lpm) laminar stream. 1 - INSTALL FAUCET AND MOUNT CONTROL MODULE A Remove nut, faucet retainer and gasket. B Install faucet into the center hole in deck or lavatory 1-3/16 (30 mm) minimum hole required. C Install mounting bracket under deck or lavatory. Install control module at a 45º angle and turn right to secure. 3

2 - INSTALL FLEX HOSE ASSEMBLY TO SUPPLY STOP AND CONTROL MODULES A Connect LED power plug and capacitance plug to control module. D Secure flex hoses to the control module by opening supply hose stainless steel clips. FROM FAUCET LED POWER PLUG CAPACITANCE PLUG IMPORTANT: IF CAPACITANCE PLUG/WIRE IS BENT/DAMAGED/ BROKEN FAUCET WILL NOT WORK. ENSURE CAPACITANCE WIRE IS AT LEAST 1/2 FROM ANY METAL, SUCH AS WATER SUPPLY. FLUSH DIRT, DEBRIS AND SEDIMENT FROM SUPPLY LINE(S) BEFORE CONNECTING FLEX HOSES. B C Install flex hose(s) onto supply stop(s). Connect hot and cold supply stop hoses to mixing valve and flex hose to connect to control module. Tighten the flex hose securely to the supply. E Close supply hose stainless steel clips. NOTE: NEVER OPEN STAINLESS STEEL CLIPS WHEN WATER SUPPLY IS TURNED ON. FROM MIXING VALVE OR TEMPERED WATER SUPPLY LINE F Insert battery assembly. 3 - ACTIVATION AND OPERATION OF FAUCET A continuous ambient field is emitted and monitored by the faucet system. As the user s hands enter the effective range the sensor activates the solenoid valve allowing tempered water to flow from the faucet. Water will flow until the hands are removed or until the faucet reaches its automatic time out setting. When hands are moved away from the faucet, the capacitance sensor deactivates the solenoid valve, shutting off the water flow. The system automatically resets and is ready for the next user. 4

4 - BATTERY REPLACEMENT NOTE: REPLACE BATTERY WHEN RED BATTERY INDICATOR LED FLASHES 4 TIMES EACH TIME FAUCET IS IN USE OR WHEN FAUCET STOPS FUNCTIONING. A B No need to turn off water. Loosen screw with hex wrench and remove cover. NOTE: IT IS POSSIBLE FOR THE FAUCET TO ACTIVATE WHEN THE CAP WIRE OR SOLENOID IS TOUCHED OR WHEN THE CONTROL MODULE COVER IS BEING SCREWED ONTO THE MANIFOLD. E Twist top of battery pack counter-clockwise to open. Remove batteries and replace batteries with four (4) new AA batteries. Twist top of battery pack clockwise to close. C Slide cover forward and lift off. D Remove battery case. F Replace cover. 5

REPLACE FILTER A Disconnect solenoid wire from control module. E Remove new filter from control module cover. B Turn solenoid caddy counterclockwise lining up arrows on control module and solenoid caddy assembly. F Snap new filter onto solenoid caddy assembly. C Remove solenoid caddy assembly from control module by pulling straight out. G Insert solenoid caddy assembly into control module lining up arrows. Turn solenoid caddy assembly clockwise 45º. Reconnect solenoid caddy wire to control module. D Remove filter from solenoid caddy assembly. 6

TROUBLESHOOTING 1. Faucet does not function. A. Batteries not installed. Install batteries. B. Capacitance cable not connected. Connect cable. 2. Faucet delivers water in an uncontrolled manner. A. Faucet is not working properly. Contact Sloan Technical Support. 3. Faucet does not deliver any water when Sensor is activated. Solenoid Valve produces an audible CLICK. A. Water supply stop(s) closed. Open water supply stop(s). B. Water supply stop strainer(s) clogged. Remove, clean, and reinstall water supply stop strainer(s). Replace strainer(s), if required. Solenoid Valve DOES NOT produce an audible CLICK. A. Battery low (battery operated models). Replace battery (refer to Battery Replacement section of guide). B. Power failure. Check power supply. 4. Faucet does not stop delivering water or continues to drip after user is no longer detected. A. Valve is not working properly. Contact Sloan Technical Support. 5. Faucet delivers only a slow flow or dribble when sensor is activated. A. Water supply stop(s) are partially closed. Completely open water supply stop(s). B. Water supply stop strainer(s) clogged. Remove, clean, and reinstall water supply stop strainer(s). Replace strainer(s), if required. C. Spray head is clogged. Remove, clean, and reinstall spray head. Replace spray head, if required. D. Faucet is not working properly. Contact Sloan Technical Support. 6. LED indicator blinks when faucet is in use. A. Battery low (battery operated models). Replace battery (refer to Battery Replacement section of guide). 7. The water temperature is too hot or too cold on a faucet connected to hot and cold supply lines. A. Supply stops are not adjusted properly. Adjust supply stops. When assistance is required, please contact Sloan Technical Support at: 1-888-SLOAN-14 (1-888-756-2614) LED DISPLAY DIAGNOSTIC CODES LED1 LED3 LED2 Function LED1 LED2 LED3 Notes Power Up Success (Battery Only Models) Power Up Success (Adapter Models) Low Battery Clean Mode Blinks 5x Blinks 1 every second (5 seconds); for battery power Blinks 3-5x Blinks 3-5x Blinks 1 every second (5 seconds); for adapter power Blinks 4x Blinks NOTE: LED1 and LED2 are for battery and programming related items. LED3 is for solenoid service. Battery power is low; During hand detection Once every 2 seconds; Touch faucet body more than 8 seconds, water hold for 2 minutes Water Hold Blinks Once every 1 second; If water turns on/off 5 times in 20 seconds, faucet turns off for 1 minute Solenoid Latch Failure Blinks Two LED blinks; After hand removed from detection zone Cap Sensor Fails to Calibrate Blinks 4 times per second; Before first water burst Detection for cable is not installed correctly Ambient Electrical Noise Too High Blinks 4 times per seconds; After first water burst CARE AND CLEANING DO NOT USE abrasive or chemical cleaners (including chlorine bleach) to clean faucets that may dull the luster and attack the chrome or special decorative finishes. Use ONLY mild soap and water, then wipe dry with clean cloth or towel. While cleaning the bathroom sink, protect the faucet from any splattering of cleaner. Acids and cleaning fluids will discolor or remove chrome plating. 7

PARTS LIST Item Part No. No. Description 1 EFX-2 Standard Crown 2 EFX-36 Control Module Mounting Kit 3 EFX-8-A Battery Pack 4 EFX-13-A Solenoid Valve Caddy 0.5 gpm (1.9 Lpm) EFX-14-A Solenoid Valve Caddy 1.5 gpm (5.7 Lpm) 5 EFX-19 Filter / Strainers 6 EFX-1003-A Control Module Assembly 0.5 gpm (1.9 Lpm) EFX-1004-A Control Module Assembly with Turbine 0.5 gpm (1.9 Lpm) EFX-1005-A Control Module Assembly 1.5 gpm (5.7 Lpm) EFX-1006-A Control Module Assembly with Turbine 1.5 gpm (5.7 Lpm) 7 EFX-31 120 VAC/6.75 VDC Plug-in Voltage Adapter 8A EAF-1 Faucet Spout Mounting Kit (Pedestal) 8B EFX-21-A Faucet Spout Mounting Kit (Integrated Base) 9 EFX-20-A 4-inch (102 mm) Centerset Base Plate Kit 10 EFX-26-A 8-inch (203 mm) Centerset Base Plate Kit 11 MIX-60-A Below Deck Mechanical Mixing Valve 12 MIX-135-A Below Deck Thermostatic Mixing Valve 13 ETF-617-A Bak-Chek Tee 14 EFX-33 Inlet Hose Fitting 15 EFX-34 Flexible Supply Hose 18 (45 mm) 16 EFX-1002-A 0.5 gpm (1.9 Lpm) Multi-Lam Spray Insert, includes: insert, o-ring, insert removal tool, and hex key EFX-1001-A 1.5 gpm (5.7 Lpm) Aerated Stream Insert includes: insert, o-ring, insert removal tool, and hex key EFX-1000-A 1.5 gpm (5.7 Lpm) Laminar Stream Insert includes: insert, o-ring, insert removal tool, and hex key 17 EAF-23-A Splitter 18 EFX-24-A 11-13/16 (300 mm) Extension Cable EFX-25-A 47-1/4 (1200 mm) Extension Cable EFX-17-A 126 (3200 mm) Extension Cable 2 14 11 12 1 8B 15 7 9 8A 10 6 4 3 5 17 16 18 NOTE: If changing flow rate, caddy and spray insert must be changed in conjunction. 13 Manufactured by Sloan Valve Company under one or more of the following U.S. Patents: 7,690, 623; 7,069,941; 6,619,320. The information contained in this document is subject to change without notice. SLOAN HEADQUARTERS 10500 SEYMOUR AVENUE FRANKLIN PARK, IL 60133 Phone: 1-800-9-VALVE-9 (1-800-982-5839) Fax: 1-800-447-8329 www.sloanvalve.com Copyright 2012 SLOAN VALVE COMPANY Code No.: 0816407 Rev. 4 (07/12)