Smart Wireless Devices. LAN-WMBUS-G Wireless MBUS, high performance Temperature, Humidity and Pulse counting device.



Similar documents
Brunata Optuna W (171)

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

Unidirectional Transmitter/ Receiver Units Introduction

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

HYDRUS ULTRASONIC METER

User Manual V SDM220MODBUS. Single-Phase Two Module DIN rail Meters

iva Cable & Antenna Analyzer

GSM HOME SECURITY SYSTEM

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Getting started with

Inwall 4 Input / 4 Output Module

Model: Manual DC: WIRELESS COLOR FORECAST STATION

MCB3101 (Class I) WiRobot Serial Bluetooth Wireless Module User Manual

RACE RESULT SYSTEM series. Decoder. Passive Antenna. Passive Transponder. Active Extension. Active Transponder.

iva Cable & Antenna Analyzer

User manual BETSO WTCS. 16 channel wireless digital TC slate. 1 Copyright BETSO ELECTRONICS Ltd.

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

TYXIA. * _Rev.1* Installation and User Guide. Wireless receiver. TYXIA RF channel

EGSTON Standard E2xFxWx 12W

QFP910. Water detector. Building Technologies. CE1N2732en Synco living

A RF18 Remote control receiver MODULE

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

FLYPORT Wi-Fi G

Drayton Digistat +2RF/+3RF

AV1200 TL-PA8030P KIT. 3-Port Gigabit Passthrough Powerline Starter Kit. Highlights

IN-OUT Thermometer with Cable Free Sensor and Clock

ABB i-bus EIB / KNX EIB Monitoring Unit EUB/S 1.1

Displayport Extender via 2 multimode fibers LC Duplex Connector Extends Displayport Link up to 200 meters

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

Adding to Z-Wave TM Network

TORKEL 820 Battery Load Unit

Model: v2 Quick Setup Guide DC: Atomic Projection Alarm with Indoor and Outdoor Temperature

The Foundation User Manual LED Battery Slim Par Fixture (RGBA, DMX 7Ch/4CH)

Quick Connect. quick - simple - efficient.

WIRELESS INSTRUMENTATION TECHNOLOGY

WIRELESS MAGNETIC CONTACT

INPUT/OUTPUT MODULE CONVERT INPUTS AND OUTPUTS TO WIRELESS

Danfoss Link Mobile Phone Butler

Quick start: Panic Watch EU

is then retained absolutely without interruption.

Monitores Equipos Móviles Especificaciones de Producto

Temperature & Humidity SMS Alert Controller

GPRS M-Bus Master. User Manual. An Economical and Practical Solution For Remote Automactic M-Bus Smart Meter Reading by GPRS In The Worldwide!

Technical Data Sheet UM-005. UM005-doc In reference to UM005-c-01.04

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

How To Use A Power Supply On A Powerline 2.2 (Ai)

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

USB-500/600 Series Low-Cost Data Loggers and Accessories

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Model: DC-A2IO Advanced HVAC Controller

9,'(2 #6(3$5$725 8VHU V#0DQXDO 96043;

4-Port Pocket. USB KVM Switch with USB 2.0 Hub

TMS TANK MANAGEMENT SYSTEM

B.IQ push button 3-5gang with room thermostat and display V2, flush-mounted x, x, x

NI USB-5681 RF Power Meter Specifications

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

Long-Range 500mW IEEE g Wireless USB Adapter. User's Guide

Remote Monitoring and REC 501 Control Unit Product Guide

Original instructions Tina 3A/Aps Adaptor unit

Wireless Data Logger. Collect, Manage and Monitor Your Valuable Data via Wireless Communication. Register and Manage Remote Units by Groups

Combi B Alarm box. Mounting instructions

USER MANUAL V5.0 ST100

Fleet Management - Smart, Secure and Easy

USB-500 Series Low-Cost Data Loggers and Accessories

USB-500 Series Stand-Alone, Low-Cost Data Loggers

Instruction Manual Service Program ULTRA-PROG-IR

Z-Wave Gas Reader. Product Manual NQ-9121-EU. From your Z-wave network directly to the cloud! DESCRIPTION

Fibaro electronic modules are smallest devices of the type in the World and can be installed in all standard wall switch boxes,

Tina 2A/B Adaptor unit

WD-AMX Water Detection Controllers

Doc.No. NDP 192U-02. Electric Pump Controller CE-124P. Instruction Manual

/ Our accessories complement all PV systems, simplify installation and ensure that the system meets the required safety standards.

Busch-Watchdog Presence EIB Type:

Counter for Energy. We make energy measurable and secure your future.

BNI IOL K006 BNI IOL K006. IO-Link Sensor-Hub analog User s Guide

Temp-485-Pt100. A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol

SR450 RECEIVER OPERATING INSTRUCTIONS

Indoor / Outdoor Antenna

FSLIMRF

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

SMART SENSOR COLLECTION

IntesisBox KNX Mitsubishi Heavy Industries AC

Vehicle GPS Tracker GP2068

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

computer radio control system

ACS-30-EU-EMDR-10-MOD

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions

GPS Hardware. GSM / GPS In-Vehicle / Personal Tracker

Push button 3gang standard flush-mounted xx

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Product Information S N O. Portable VIP protection CCTV & Alarm System 2

RDF1. RF Receiver Decoder. Features. Applications. Description. Ordering Information. Part Number Description Packages available

Temperature & Humidity SMS Alert Controller

RRV934. Multi-controller. Synco living

Digital input modules

Transcription:

Smart Wireless Devices LAN-WMBUS-G Wireless MBUS, high performance Temperature, Humidity and Pulse counting device. The LAN-WMBUS-G-T(E)/(H)-(P) is a temperature/humidity sensor and pulse counter. It is used for measuring ambient temperature and for counting pulses from water meters, energy meters etc. The device has the following advanced features; Wireless MBUS EN13757-3/4:2013 Standard. S, T and C- mode are supported. Superb antenna design and high output power for long range. On board temperature sensor. (T), (TE), (TH). Humidity sensor (TH) 2 Digital pulse inputs (P) Sabotage detection if opened of removed from wall. AES 128 encryption. CBC Mode 5 OMS compliant. Very long battery lifetime, typical at least 16 years. Wide operating temperature range - 20 to +55 degree C. Plug & Play. Works right out the box, no complex installation needed. Low battery alarm. Available with optional high quality battery.

Product Matrix Article Number Temperature sensor range Accuracy typical at 25 degrees C. Humidity sensor External inputs LAN-WMBUS-G-T 0 to +45 gr C ± 0.3 - - LAN-WMBUS-G-T-P 0 to +45 gr C ± 0.3-2 LAN-WMBUS-G-TE -20 to +55 gr C ± 0.3 - - LAN-WMBUS-G-TE-P -20 to +55 gr C ± 0.3-2 LAN-WMBUS-G-TH -20 to +55 gr C ± 0.3 Yes - LAN-WMBUS-G-TH-P -20 to +55 gr C ± 0.3 Yes 2 LAN-WMBUS-G-P - - - 2 Temperature and humidity characteristics for the TH and TE device. Temperature characteristics for TH and TE device if the high precision temperature sensor is added, contact us for more information. SE-301 05

Radio characteristics Frequency Chiprate S-Mode 868.3 MHz T-Mode 868.95 MHz C-Mode 868.95 MHz S-Mode 32.378 kcps T-Mode 100 kcps C-Mode 100 kcps Datarate S-Mode Chiprate /2 T-Mode Chiprate x 2/3 C-Mode Chiprate RF output power Antenna Transmission intervals Retransmission 12 dbm Integrated 15 minutes (other intervals are also available upon request) 30 seconds during the first 4 minutes after powerup. 3 times in total. Power and battery Power consumption Battery type Max 40 ma, SAFT LS 14500 3.6 V - AA Primary Li-SOCL2 (recommended) Max operating voltage 3.6V Minimum operating voltage 2.8V Lifetime Typical more than 16 years. Depends on MBUS mode, pulses/s, transmission interval etc. Contact us for more information. W-MBUS Info Header type EN13757-3 APPLAYER LONG TRANSPORT HEADER (0X72) Encryption AES 128 CBC (mode 5) Sensor type Low battery warning Manufacture code 0x1B Room sensor device (standard other setting if requested) This setting can be ordered to any other value but has probably no use if the only interest is the number of pulses and the conversion is handled on the server-side. Yes LAS (standard, other code if requested) SE-301 05

-T, TE and TH variant Temperature value 4 BCD digits, 1 decimal ex 201 = 20.1 gr C) ex F201 = - 20.1 gr C. Humidity value 2 BCD digits, 0 decimal (ex 20 = 20 %) -P variant Pulse value. Example: 012345678912 Pulse conversion Number of input ports Valid inputs Minimum pulse width 12 BCD digits, instantiations accumulated value from the power up of the device No conversion, Units for H.C.A Dimensionless. 2 Digital Digital signal 0V and 2.8-3.6V or an open close circuit. Interrupt based > 5 Ms. Operating conditions Storage temperature Operating temperature, Relative moisture - 55 to + 85 gr C -20 to + 55 gr C Less than 95% non-condensing Casing Colour Dimensions Material White 25,5 x 88,5 x 32 mm ABS Conformity EMC EN 301489 Safety EN 60950 Radio EN 300 220 SE-301 05

Features for easier installation. Red LED indication when inputpulse is detected Red LED indication when sabotage is detected Red LED indication when sabotage is restored When: During 4 minutes from the point a battery was inserted into the device. What: The LED lights up for 2 seconds after a pulse is sensed on either of the digital inputs. Why: In order to verify that the cable connection is working correctly and that the installation was successful. When: When the device is opened or removed from the wall. (sabotage is detected) What: The LED flashes for 4 seconds at 4 Hz. Why: In order to verify that the sabotage detection is working. When: When the device is closed or placed against the wall again(sabotage is restored) What: The LED flashes for 2 seconds at 1 Hz. Why: In order to verify that the sabotage is restored and the device is closed and mounted correctly. MBUS - Data format. Sabotage Detected Message. The sabotage message is always sent in two ways: Sabotage using Error Flag message. The message is only sent when the status of sabotage is changed. 0x02; (DIF field 2 byte integer) 0xFD; (VIF Extension table) 0x17; (VIFE Error flags binary manufacture specific 16 bits) (2 bytes) Sabotage detected.xxx1x (Bit 1) Sabotage restored.xxx0x (Bit 1) Sabotage using the manufacture specific status-byte in EN13757-3 APPLAYER LONG TRANSPORT HEADER (0X72). The bit is set to 1 as long as sabotage is detected. Sabotage detected 1 (Bit 5) Sabotage restored 0 (Bit 5) Low battery Low battery is sent using the power low bit in the status-byte in EN13757-3 APPLAYER LONG TRANSPORT HEADER (0X72) Battery low 1 (Bit 2) Battery OK 0 (Bit 2) SE-301 05

Humidity Humidity 20% DATA_FIELD_BCD_2_DIGIT VIF_VIFE_EXTENSION_TABLE_USED_INSTEAD VIFE_RELATIVE_HUMIDITY_0_DECIMAL Humidity Value 0x09 0xFB 0x1B 0x20 Temperature DATA_FIELD_BCD_4_DIGIT; VIF_EXTERNAL_TEMPERATURE_TENTH_OF_DEGREE; Temperature Value Temperature 20.3 grc 0x0A 0x66 0x02,0x03 Pulses Number of pulses 012345678912 DATA_FIELD_BCD_12_DIGIT; VIF_HCA_DIMENSIONLESS; Number of pulses detected 0x0E 0x6E 0x01,0x23,0x45,0x67,0x89,0x12 Changelog Revision 1.4 Changed the Led indication for sabotage. Clarified the sabotage and low battery information. Sabotage detection is no longer optional. Temperature accuracy is now always 0,3 gr C if not higher is requested. Updated information regarding battery lifetime. Revision 1.3 Changed from Pulse conversion 10 lites/pulse to H.C.A dimensionless Martin Hallberg 2015-05-11 Martin Hallberg 2015-02-19 SE-301 05