SANbox Manager Release Notes Version 1.03.28 50208-06 Rev A



Similar documents
QLogic 3810, QLogic 5000 Series, and QLogic 5800V Series Switch Firmware. Version Table of Contents

HP StorageWorks 4/10q Fibre Channel Switch management user guide

Enterprise Remote Control 5.6 Manual

PTC Integrity Eclipse and IBM Rational Development Platform Guide

NovaBACKUP Storage Server User Manual NovaStor / April 2013

Chapter 4 Management. Viewing the Activity Log

QLogic Virtual Fabric Extension Module for IBM BladeCenter

new Business Online Technical Troubleshooting Guide

OFFICE KEYBOARD (MT1210 & MT1405) OFFICE FEATURES

SAM Server Utility User s Guide

IBM Remote Lab Platform Citrix Setup Guide

SNMP Manager User s Manual

SNMP Manager User s Manual

User s Manual. Management Software for Inverter

SOS SO S O n O lin n e lin e Bac Ba kup cku ck p u USER MANUAL

WhatsUp Gold v16.3 Installation and Configuration Guide

3M Stats and Status Software for 3M Detection System Model 8900/9900. Administrator s Guide

Working With Your FTP Site

CA /BrightStor ARCserve9 Backup Software

User s Manual. Management Software for ATS

IriScene Remote Manager. Version 4.8 FRACTALIA Software

Reflection DBR USER GUIDE. Reflection DBR User Guide. 995 Old Eagle School Road Suite 315 Wayne, PA USA

Backup & Disaster Recovery Appliance User Guide

Compuprint 4247 Serial Matrix Printers

Chapter 3 Management. Remote Management

ViewPower User Manual

System Area Manager. Remote Management

Nortel Networks Call Center Reporting Set Up and Operation Guide

ViewPower. User s Manual. Management Software for Uninterruptible Power Supply Systems

How To Install An Aneka Cloud On A Windows 7 Computer (For Free)

Esi-Mail. Setup and User s Guide. Visit for up-to-date help Rev. A

AccXES Account Management Tool Administrator s Guide Version 10.0

LICENSE4J FLOATING LICENSE SERVER USER GUIDE

User s Manual. Management Software for Uninterruptible Power Supply Systems

Attix5 Pro Server Edition

Moldplus Server Installation Guide Version 3.10 Revision date: February 05, 2006

Topaz Installation Sheet

User Guide for VMware Adapter for SAP LVM VERSION 1.2

VMware vcenter Support Assistant 5.1.1

InfoPrint 4247 Serial Matrix Printers. Remote Printer Management Utility For InfoPrint Serial Matrix Printers

QIAsymphony Management Console User Manual

User Manual WatchPower

2. Installation and System requirements

Online Backup Client User Manual Linux

Appointment Scheduler

Qsync Install Qsync utility Login the NAS The address is :8080 bfsteelinc.info:8080

How To Use Senior Systems Cloud Services

Dell SupportAssist Version 2.0 for Dell OpenManage Essentials Quick Start Guide

Tracking Network Changes Using Change Audit

Sync IT. Detailed description of program. Tab: Sync

WhatsUp Gold v16.1 Installation and Configuration Guide

Workflow Automation Support and troubleshooting guide

Go to CGTech Help Library. Installing CGTech Products

Avalanche Site Edition

Upgrading from Call Center Reporting to Reporting for Call Center

5-Bay Raid Sub-System Smart Removable 3.5" SATA Multiple Bay Data Storage Device User's Manual

Volume SYSLOG JUNCTION. User s Guide. User s Guide

c. Securely insert the Ethernet cable from your cable or DSL modem into the Internet port (B) on the WGT634U. Broadband modem

NVMS User Manual

Performing Database and File System Backups and Restores Using Oracle Secure Backup

Troubleshooting AVAYA Meeting Exchange

Apple Server Diagnostics User Guide. For Version 3X106

HP Business Availability Center

Getting Started with Vision 6

User Guide Win7Zilla

Cisco 831 Router and Cisco SOHO 91 Router Cabling and Setup Quick Start Guide

SMS (Server Management Software) Digital Video Recorder. User s Manual

ViewPower Pro. User s Manual. Management Software for Uninterruptible Power Supply Systems

Advanced Event Viewer Manual

Agilent System Protocol Test Release Note

NovaBACKUP. Storage Server. NovaStor / May 2011

SANsurfer FC HBA Manager Application User s Guide for OEMs

HP A-IMC Firewall Manager

Remote Backup Software User Manual V 2.0

README.TXT

WebEx Remote Access User s Guide

Network Monitoring. SAN Discovery and Topology Mapping. Device Discovery. Send documentation comments to

Introduction. Installation of SE S AM E BARCODE virtual machine distribution. (Windows / Mac / Linux)

COMMANDS 1 Overview... 1 Default Commands... 2 Creating a Script from a Command Document Revision History... 10

Installing, Uninstalling, and Upgrading Service Monitor

AMD RAID Installation Guide

Embarcadero Performance Center 2.7 Installation Guide

Charter Business Desktop Security Administrator's Guide

ImagineWorldClient Client Management Software. User s Manual. (Revision-2)

1. Product Information

IceWarp to IceWarp Server Migration

Network Probe User Guide

VMware vsphere 5 Quick Start Guide

Cisco Networking Academy Program Curriculum Scope & Sequence. Fundamentals of UNIX version 2.0 (July, 2002)

HP StorageWorks 8/20q Fibre Channel Switch QuickTools switch management user guide

OPENLANE PERFORMANCE WIZARD

TSM for Windows Installation Instructions: Download the latest TSM Client Using the following link:

5.0 Secure Meeting Error Messages

HP IMC Firewall Manager

Pharos Control User Guide

ZENworks 11 Support Pack 4 Full Disk Encryption Agent Reference. May 2016

Guest PC. for Mac OS X. User Guide. Version 1.6. Copyright Lismore Software Systems, Ltd. All rights reserved.

Freshservice Discovery Probe User Guide

Global Image Management System For epad-vision. User Manual Version 1.10

Transcription:

SANbox Manager Release Notes Version 1.03.28 50208-06 Rev A This software is licensed by QLogic for use by its customers only. Copyright (c) 2001 QLogic Corporation All rights reserved Version 1.03.28 is a feature release of the QLogic SANbox TM Manager Fabric Management Application. SANbox2 TM version 1.3.25 and SANbox version 4.01.45 firmware, or greater, must be used in conjunction with SANbox Manager. SANbox Manager does not support the legacy T_Port mode and therefore does not interface with MKII switches or SANbox switches in T_Port mode. Features in this Release Version 1.03.28 provides the following features: User Preferences You can choose to configure the following options: o Working directory set the location for files to be saved. The default is the user s home directory. o Browser location location for the internet browser to be used to display on-line help. o Polling frequency how often SANbox Manager polls the switch for updated information. o View file auto save and load enable or disable having the default fabric view file automatically saved each time you exit SANbox Manager. The default is enabled. o Preferred initial port view choose whether your default port view, in the faceplate display, displays each port s mode, state, speed or media. Any alternative view may be selected from the faceplate display. Also, all information is listed in the Port Info tab in the faceplate display regardless of the port view displayed. Archive/restore chassis configuration to a file - If a switch must be replaced, you can save the configuration information to a file, replace the switch and restore that configuration information to the new switch. These options are found in the Switch menu in the faceplate display. Set beacon on switch If you need to easily locate a specific switch, set the beacon on that switch. This will cause the switch LEDs to blink. To set beacon, select Toggle beacon from the Switch menu.

Simple Broadcast Support This feature allows for a frame to be broadcasted to the entire fabric, including outside vendor switches, when those vendors support this functionality. Broadcast frames are not sent out to TL ports. To enable this feature, select Switch Properties from the Switch menu and then enable Broadcast support. On-line diagnostics support The Port Loopback Test, available via the Port menu, now supports internal, external and online port tests. o The internal test is a loopback test and can only be performed on a port that is in a diagnostic state. The internal loopback tests all of the hardware on the port and may be useful in situations where it is inconvenient to install a loopback plug in a port. o The external test is a loopback test and can only be performed on a port that is in a diagnostic state and has a loopback plug installed. This tests all of the hardware on the port and provides the highest level of test coverage of the three types of port tests. o The online test can be performed on any port with an active login. Remote logging via syslog - Logs can now be spooled remotely as well as being written to local flash. To use this feature, select Enable Remote Logging (syslog) from Network Properties. Once selected, you need to enter an IP address of a UNIX machine that is running syslog in the Logging (syslog) Host IP Address box. Refer to the SANbox2 Firmware Release Notes for an example of how to set up logging on the UNIX machine. Platform requirements Host OS 2.8 Memory Disk Space Processor Windows NT, Windows 95/98, Windows 2000, Linux (RedHat 6.2), Solaris 128MB 150MB per installation 300MHz Patch Requirements This version of SANbox Manager uses, and includes, Java 2 SDK, Standard Edition, v1.4.0. The SUN site below references patches that are required to be installed on your Solaris system in order to work with this version. http://java.sun.com/j2se/1.4/install-solaris-patches.html Documentation Installation, setup and management of the SANbox2 switch are described in the following manuals. These manuals are available on the SANbox2 distribution CD. SANbox2 Switch Management User's Manual, Publication No 59022-03 Rev. B SANbox2-16 Fibre Channel Switch Installer's/User's Manual, Publication No 59021-03 Rev. B

Installation, setup and management of the SANbox switch, running 4.01 firmware with E_Port, are described in the following manuals. These manuals are available only through QLogic Technical Support. SANbox-8/16 with E_Ports Switch Management Manual, Publication No. 59033-00 Rev. A SANbox-8 with E_Ports Fibre Channel Switch Installer s/user s Manual, Publication No. 59030-00 Rev. A SANbox-16STD with E_Ports Fibre Channel Switch Installer s/user s Manual, Publication No. 59031-00 Rev. A SANbox-16HA with E_Ports Fibre Channel Switch Installer s/user s Manual, Publication No. 59032-00 Rev. A Issues Corrected in this Version Problem Symptom ID 3601 Drag and drop of zone members in the Zoning window is not consistent on a Solaris platform. If failure occurs, use the menu buttons instead. 3610 Warning messages are displayed when installing on a Solaris platform. The messages can be ignored. They include: Warning: Name: HorScrollba Class: XmScrollba The specified Scrollbar value is greater than the maximum Scrollbar value minus the Scrollbar slider size 3649 Highlighting multiple members for zoning using the control button does not work. All items are no longer highlighted when zone is selected. 3904 There have been a few circumstances where the GUI becomes unresponsive to mouse clicks. To recover from this, hold down the <ctrl> key while clicking on the left mouse button. 4057 Occasionally when you minimize the SANbox Manager application and then attempt to maximize it, it will not come up. On a windows platform, bring up the Task Manager, select SANbox Manager, select End Task and then restart the application. On a UNIX platform, kill the SANbox Manager process.

Known Installation and Packaging Issues Problem Symptom ID 4321 The uninstall script is located in the UninstallerData subdirectory instead of the main installation directory. 4324 If installing on a UNIX platform as root, you cannot install in the home directory. 4392 After the installation is complete, the installer may tell the user to click Done to quit the installer when the user really must click Next and then Done. 4466 On the 'Install Complete" screen, if the user selects the "Previous" button, all other buttons become inactive and the user is forced to make an un-graceful exit. Note that at this point, the GUI has already been installed. 4467 When exiting the Installer, an "Install Not Complete" message is received that states ["...To cancel Install select "Quit"" and "...If you exit, the SANbox Manager will not be installed."] The installation is not cancelled and the SANbox Manager remains installed even if the "Quit" button is selected.

Known Functionality Issues Problem Symptom ID 4250 When scrolling through the Trap log, the refresh of the window places the scroll position at the bottom of the window. A work around would be to export the trap log and view with an editor. 4328 If you make a change, for example changing port state, that change may not be instantaneous and no wait message or other indication is given. 4338 SANbox Manager disappeared unexpectedly, leaving behind a core file in the install directory. This is caused by Sun Bug ID: 4641535 "JDK 1.4 Solaris: memory leak when remote displaying". The workaround is to define the environment variable J2DFONTSCALER=t2k before running the GUI: #export J2DFONTSCALER=t2k #SANbox_Manager 4340 After running for approximately 18 hours, SANbox Manager had an out of memory exception error. This is caused by Sun Bug ID: 4641535 "JDK 1.4 Solaris: memory leak when remote displaying". The workaround is to define the environment variable J2DFONTSCALER=t2k before running the GUI: #export J2DFONTSCALER=t2k #SANbox_Manager 4411 When launching SANbox Manager, you may receive an error regarding your font settings. For example, "Cannot convert string monotype arial regular..." This is a configuration issue with X-windows and does not affect the functionality of the GUI. The font path of the machine whose X-server is displaying the application needs to have a directory which either has the specified font (Arial) or a font alias to re-map it to another font. For example, you might add the /usr/openwin/lib/x11/truetype directory to the font path on the machine that is displaying SANbox Manager (not the machine on which the application is executing). This can be done using the sdtfontadm utility, and must be done as root. 4417 The Load Firmware and Edit Zoning dialog boxes can become hidden behind the main window and give the appearance that the GUI is hung. 4533 Drag and drop from Zoning dialog to application window hangs the GUI. This is caused by Sun Bug ID: 4633417 and 4623377. 4562 The port loopback test times out occasionally on a multi-processor system. 4692 When changing DomainID to a value greater than 31, a warning message is presented telling you that the DomainID is invalid but the operation is allowed. 4763 On Windows based PCs, on occasion the GUI will abort when entering the faceplate display. Restarting the GUI will correct this problem. This bug is caused by Sun Bug ID: 4482430, 4500800 and 4523926. 4764 If an ISL goes down between a SANbox2 and McData switch, the ISL state is

sometimes not reflected until you click on Refresh. 4765 If set switch state is used in CLIsh to set the switch offline, the GUI does not recognize this state. This is because set switch state in CLIsh is a temporary setting. The GUI reflects the permanent setting set by set config switch. 4774 With a mixed SANbox 1Gb and SANbox2 switch configuration, if you add a fabric to SANbox Manager by entering the IP address of a SANbox 1Gb switch, there are intermittent performance problems. This is noticed by occasional short delays in processing requests and/or the switches not responding (blue status icons) for a few seconds. 4791 When running offline/online tests on E_Ports, the GUI will occasionally show a port as offline when it is actually online and operational. A workaround is to do a fabric refresh. The correct port states will then show up. 4792 When changing the switch configuration in telnet back and forth between offline and online, the GUI got into the state where it believed the switch was in the offline state. A refresh will correct this problem. When running from a remote login, the font size used for the text in the Help file is too small to read. This is just an X Window font config issue. Edit (or create) a.xdefaults file in your home dir (/ for root) and put the following lines in it: Netscape*documentFonts.xResolution*iso-8859-1: 100 Netscape*documentFonts.yResolution*iso-8859-1: 100 While the above changes may provide a solution, in some cases it may not. In such cases, the user may also be able to resolve the small font size by modifying the font preferences in Netscape to be "Use my default fonts, overriding document specified fonts." 4814 If a saved fabric is restored and has a switch with a Domain ID that conflicts with an active switch in the fabric then the fabric is not displayed correctly. ISLs are not mapped correctly in the fabric. Rediscover of the fabric will display them correctly. 4818 The GUI may lock up during fabric rediscovery after doing zone deletion, creation, and merging. The GUI will repaint the screen and return to normal operation, but this may take several minutes. 4825 After a reset of the entry switch of an 8 switch mesh, one of the other switches was left in the blue "no response" state though it could be accessed by Telnet. The refresh button did not clear the problem, although rediscovering the fabric did. This is a very intermittent problem. Support Please feel free to contact your QLogic approved reseller or QLogic Technical Support at any phase of integration for assistance. QLogic Technical Support can be reached by the following methods: Web: http://www.qlogic.com/support/report_problem.asp Email: support@qlogic.com Phone: (952) 932-4040