Radiant Dyes Laser Accessories GmbH



Similar documents
Measuring Laser Power and Energy Output

DIODE PUMPED CRYSTALASER

TPC laser calibration system

SpectraTec II. Polarized Multi-Laser Source BLUE SKY RESEARCH WAVELENGTHS. The SpectraTec II

Millijoules high master-slave pulse ratio 532 nm picosecond laser

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

Quasi-Continuous Wave (CW) UV Laser Xcyte Series

We bring quality to light. MAS 40 Mini-Array Spectrometer. light measurement

Experiment 5. Lasers and laser mode structure

Remote Level Monitoring Unit

Single Mode Fiber Lasers

HP 70950B OPTICAL SPECTRUM ANALYZER

Excimer Lasers for Super-High NA 193 nm Lithography

MCP 100 MCP 150. Modular Compact Polarimeters. ::: Superior Optical Instruments

Status of the Free Electron Laser

HIGH POWER FREE SPACE AND FIBER PIGTAILED ISOLATORS

A More Efficient Way to De-shelve 137 Ba +

Designing and Manufacturing Femtoseconds Ultra-broadband Lasers: Proven, Hands-free Reliability

AMPLIFIED HIGH SPEED FIBER PHOTODETECTOR USER S GUIDE

Barcode positioning systems BPS 8, BPS 34/37 Innovations that truly move you forwards.

LBS-300 Beam Sampler for C-mount Cameras. YAG Focal Spot Analysis Adapter. User Notes

Short overview of TEUFEL-project

A METHOD OF PRECISE CALIBRATION FOR PIEZOELECTRICAL ACTUATORS

Sound absorption and acoustic surface impedance

RIEGL VQ-480. Airborne Laser Scanning. Airborne Laser Scanner with Online Waveform Processing. visit our website

LI-7000 CO /H O Analyzer. High Speed, High Precision Differential Analyzer

PUMPED Nd:YAG LASER. Last Revision: August 21, 2007

TATA INSTITUTE OF FUNDAMENTAL RESEARCH Homi Bhabha Road, Colaba, Mumbai A Deemed University

# 2. Selecting and Using Thermistors for Temperature Control

Maintenance Management on LMJ H. GRAILLOT, I. GRANET CEA/CESTA/DLP

Agilent Cary 4000/5000/6000i Series UV-Vis-NIR

Full Waveform Digitizing, Dual Channel Airborne LiDAR Scanning System for Ultra Wide Area Mapping

Optical Fiber Switches

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

SFG spectrometers. Sum Frequency Generation Vibrational Spectroscopy. More than 20 years experience

ULTRAFAST LASERS: Free electron lasers thrive from synergy with ultrafast laser systems

ROFIN FL SERIES. High Brightness Fiber Lasers Precise, Fast and Reliable.

Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE

6) How wide must a narrow slit be if the first diffraction minimum occurs at ±12 with laser light of 633 nm?

Indoor / Outdoor Antenna

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

How To Use A Ds340 (Dsp)

Industrial Bar Code Scanners

How a laser works. LASER light amplification by stimulated emission of radiation. Contains the excitable atoms MEDIUM

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Single-frequency-mode Q-switched Nd:YAG and Er:glass lasers controlled by volume Bragg gratings

Vertical Cavity Surface Emitting Laser OPV300, OPV310, OPV310Y, OPV314, OPV314Y

MEMS mirror for low cost laser scanners. Ulrich Hofmann

ILX Lightwave Corporation

R E Q U E S T F O R Q U O T A T I O N. ENQUIRY NO. NAL/ABP/ EAD/104/2010F January 11, 2011

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

Sense it! Connect it! Bus it! Solve it! EncoderS

Ti:Sapphire Lasers. Tyler Bowman. April 23, 2015

UV-NIR LASER BEAM PROFILER

DIRECTIONAL FIBER OPTIC POWER MONITORS (TAPS/PHOTODIODES)

Understanding Laser Beam Parameters Leads to Better System Performance and Can Save Money

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

Transmitter Interface Program

SSI. Modbus Analogue Output DEVICENET ETHERNETIP. Zero Slip, Zero Wear. Exact Measurement. No Moving Parts. Permanently Calibrated.

73 Series Spectrophotometers

High-Performance Wavelength-Locked Diode Lasers

LNG Monitoring. Fiber-Optic Leakage Detection System. Pipeline leakage detection. Regasification and liquefaction monitoring

APPLICATION NOTE AP050830

Development of MEMS micromirrors for intracavity laser control

RAY TRACING UNIFIED FIELD TRACING

Material test chamber with mechanical convection

PMP 4000 Series. Druck Amplified Output Pressure Transducers. GE Sensing. Applications. Features

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

Measurement of Enhanced Specular Reflector (ESR) Films Using a LAMBDA 1050 UV/Vis/NIR Spectrometer and URA Accessory

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6

Agilent Cary 60 UV-Vis

CL90i Please read these instructions before operating the product. 3 - Beam Self-Leveling Cross Line Laser

Introduction to Diode Lasers

Acousto-optic modulator

PIPELINE LEAKAGE DETECTION USING FIBER-OPTIC DISTRIBUTED STRAIN AND TEMPERATURE SENSORS WHITE PAPER

instruments Analytical Instruments for Science

Kit Highlights and Key Features

Physical Specifications (Custom design available.)

SGS: Das Scanning Grating Spektrometer Ein kleines, günstiges Spektrometermodul auf Basis eines dispersiven Mikrosystems

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

Helium-Neon Laser. Figure 1: Diagram of optical and electrical components used in the HeNe laser experiment.

APPLICATION NOTE ULTRASONIC CERAMIC TRANSDUCERS

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

Argon-Ion Lasers. Argon Ion Lasers. for industrial and scientific applications. Sacher Lasertechnik GmbH Rudolf-Breitscheid-Str. 1-5 D Marburg

Recent developments in high bandwidth optical interconnects. Brian Corbett.

A Guide to Acousto-Optic Modulators

High Power Fiber Laser Technology

Automated part positioning with the laser tracker

How To Use A Karlsruhe Doppler Lidar

Precision Lightmeters Made in Germany

Alignement of a ring cavity laser

How To Use Bodescan For 3D Imaging Of The Human Body

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

High Brightness Fiber Coupled Pump Laser Development

Development and Commissioning of the Orion Laser Facility

VWR SPECTROPHOTOMETERS

A NEW LOOK AT RISLEY PRISMS. By Craig Schwarze Senior Systems Engineer OPTRA Inc.

Mach 5 User s Manual Revision 2.0 1

Transcription:

New NarrowScan New Resonator Design Improved Sine Drive Unit Autotracking Frequency doubling, tripling and mixing Wavelength Separation Unit Frequency Stabilization Temperature Stabilization Wavelength Calibration Online Bandwidth Control Bethune Cell (up to 1 Joule pump energy) Optional: Integrated Nd:YAG Laser Radiant Dyes Laser Accessories GmbH Friedrichstr. 58 Germany 42929 Wermelskirchen ++49 (0) 21 96-8 10 61 + 926 85 Fax ++49 (0) 21 96-34 22 http://www.radiant-dyes.com E-mail: info@radiant-dyes.com

NarrowScan The NarrowScan pulsed dye laser series is based on a new resonatordesign with a very narrow linewidth (< 0.04 cm -1 ) that has been optimized in design and specifi cations by laser experts over many years and can now be used with pump laser pulses as short as 4 ns. The laser has very rigid and massive middle and side plates, ensuring a very high stability in the oscillator and pre-aplifi er. The dimensions of the laser housing are much smaller than before, making the laser as compact as possible, while still allowing space for two frequency conversion units inside the laser. Improved Resonator Design vertical grazing incidence resonator larger tuning range lower bandwidth improved pulse to pulse energy stability New NarrowScan laser with the following options: Gratings: 1800, 2400, 3000, 3600 lines/mm Double-grating (bandwidth < 0.04 cm -1 ) Prismatic cell for high power output Frequency conversion units for doubling, trippling or mixing from 190 nm up to 4.5 µm Look up table and /or autotracking for both conversion units Wavelength separation with two or four Pellin-Broka-Prism Temperature stabilization of the crystal-housing Frequency stabilization Optogalvanic cell for laser calibration C++ or LabView software 4 digital and 4 analog inputs Online power monitoring of fundamental, doubled and tripled laser light Online bandwidth monitoring with CCD-camera Reversed laser design Integrated pump laser (dye and pump laser in a single housing)

b) Temperature Stabilization Our new NarrowScans are provided with an active temperature stabilization to prevent instabilities of the cavity because of changing environmental temperatures. c) Opto-Galvanic Wavelength Calibration A software controlled opto-galvanic calibration device measures the absolute wavelength of atomic transitions, which are compared to the actual grating position. The user can use the data to recalibrate his laser. d) Bandwidth Monitor An Etalon is used to generate interference rings, which are monitored by a CCD-camera and displayed on the PC. The software calculates the laser bandwidth by fi tting the interference maxima, allowing an online control of the laser bandwidth during the measurements.

e) Wavelength / Frequency Stabilization The active frequency stabilization uses the same Etalon as for the bandwidth measurement. In order to stabilize the laser frequency, one of the interference maxima is observed and kept at the same spatial position. Any frequency drift of the dye laser results in a spatial drift of the interference rings, which is compensated for by slightly adjusting the resonator. f) Prismatic cell for high power output and improved beam profile Our new prismatic cell can be used with pump powers up to 1 Joule and garantees a high power output with an excellent beam profi le. The inner tube can be ordered from 1.6 up to 6 mm diameter, depending on the power of the pumplaser.

The highly compact laser design makes it possible to integrate a Nd :YAG Laser of the Innolas Spitlight series to ensure an independent and ultrastable operation. Additional options When designing the new series of NarrowScan dye lasers we paid utmost attention to a fl exible layout, meeting a variety of applications with a single dye laser. The following options can be easily integrated into the housing of the NarrowScan laser to guarantee a rigid and compact structure. a) Frequency conversion The excellent spectral and spatial quality of the NarrowScan-series predestinate this laser for the use in nonlinear processes. By means of our very precise positioning devices, all common crystals for frequency doubling, tripling and difference frequency mixing or mixing after doubling can be installed in the housing of the NarrowScanlaser. By installing the positioning stage directly inside the laser housing, a high stability and reproducibility is achieved. For difference frequency mixing (up to 4.5 µm) the dye laser wavelength is mixed with the fundamental of the Nd:YAG-laser. The necessary opto-mechanical components for the pump laser beam are also located inside the laser housing. All frequency units can be used independend, in LookUpTable or in autotracker mode. Frequency doubling Doubling Unit & Pellin Broka Separation Box Difference frequency mixing Frequency tripling (13) compensators; (14) mixing-crystal; (15) separator (Pellin-Broka prism); (16) λ/2-plate

Specifications NarrowScan D-R NarrowScan G-R NarrowScan GK-R Linewidth < 0.04 cm -1 (typically 0.02 cm -1 ) < 0.06 cm -1 (typically 0.04 cm -1 ) < 0.1 cm -1 (typically 0.05cm -1 ) Conversion effi ciency: Excimer pumped 308 nm 12 % Rhodamine 6G 15 % Coumarin 102 14 % Rhodamine 6G 17 % Coumarin 102 14 % Rhodamine 6G 17 % Coumarin 102 Conversion effi ciency: Nd:YAG pumped 532 nm 22 % DCM 28 % Rhodamine 6G 25 % DCM 29 % Rhodamine 6G 25 % DCM 29 % Rhodamine 6G Wavelength reproducibility (580 nm) Absolute accuracy of the wavelength (580 nm) Wavelength Stability Divergence < 0.0025 nm (typically < 0.0009 nm), temperature stabilized < 0.02 nm (typically < 0.01 nm), temperature stabilized < 0.001 nm / o C 0.5 mrad Polarization > 98 % ASE-background < 0.5 % Dimensions: 1110 mm x 420 mm x (350... 380) mm Configuration: Grazing Grating Tuning Element Tuning Range 1800 l/mm Mirror 350 nm... 950 nm 1800 l/mm 1800 l/mm 350 nm... 850 nm 2400 l/mm Mirror 330 nm... 800 nm 2400 l/mm 2400 l/mm 330 nm... 720 nm 3000 l/mm Mirror 330 nm... 610 nm 3000 l/mm 3000 l/mm 330 nm... 580 nm 3600 l/mm 3600 l/mm 330 nm... 480 nm Requirements: Pump laser power Voltage Computer (not included) 20 mj... 1000 mj, (one main amplifi er) 110 V 6 A / 220 V 3 A, 50/60 Hz, single phase Windows (all versions), Linux or Mac, one free serial or USB port for the communication with the control unit All NarrowScan dye lasers are equipped with ready-to-use Radiant Dyes dye circulators (standard models for up to 50 Hz repetition rate of the pump laser). The pump optics can be chosen by the customer, according to the wavelength and the beam profi le of the pump laser. The laser can either be controlled by a PC via the RS 232 or USB interface or an independend control box with a fully functional keyboard.