Floodlight Range Installation Guide



Similar documents
Operating Instructions

Linear Luminaire with LED Series EXLUX 6402/2

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FOR EXHEAT INDUSTRIAL IMMERSION HEATERS (INCLUDING FLAMEPROOF)

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Operating Instructions

Instructions for Safe Use

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL

EXPLOSION-PROOF EMERGENCY LIGHTING FIXTURE FOR FLUORESCENT LAMP EVF-..-EL SERIES

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Manual. Solar Fountain Mobile Phone Charger

Plug and Socket Devices SolConeX 16 A Series 8570

SEISMIC VELOCITY TRANSDUCER T1-40

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

Plug and Socket Devices CES 63 A Series 8579

ACS-30-EU-EMDR-10-MOD

Terminal Boxes Series 8146

Flow switches Series AD/VH

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications

Technical Specifications

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Wolflite Safety Handlamp H-251E

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

8146/5 Series Breaker Panelboards

Control and Distribution Boxes made of Stainless Steel Series 8150

IIB+H2 Flameproof Ex d enclosures EJB Aluminium & Stainless steel

Explosion proof enclosures

Technical data sheet TDS0070

Safety instructions VEGAPULS PS62/63/66/67/68.GI/RI(*)****** IECEx BVS Ex t IIIC T Da, Da/Db, Db IP 66

Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design

Brochure. Light fittings, floodlights and beacons New LED range for hazardous areas

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

Terminal Box. Specifications TNCN

Compact pressure switch Flameproof enclosure Ex d Model PCA

Inductive sensor NI10-M18-Y1X-H1141

A good connection. International approvals.

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

FIRERAY 2000 Installation Guide

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

D/N VARI-FOCAL IR CAMERA

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

TABLE OF CONTENTS. Hurricane 1300 User Manual 2 Rev. 4

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

din din-s 90Ah/plate 155Ah/plate 115Ah/plate 140Ah/plate

Emergency lighting units EM powerled

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Redundancy Module QUINT-DIODE/40

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

2.12. page Products for Explosion hazardous Environment

V94 BULK TAPE DEGAUSSER

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Technical Data. Dimensions

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

4/2-Way Pneumatic Solenoid Valve

Drayton Digistat +2RF/+3RF

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Bubble King. User Manual

Flameproof Audible Signal 115 db (A) Series YA90

1756 ControlLogix Chassis Specifications

3DLevelScanner II TECHNICAL DATA SHEET

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Abtech Custom Solutions

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

CompactLogix Power Supplies Specifications

Software and Display instruments

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

CO2 Alarm. Operation. Application

Infrarot-Bewegungsmelder IP44

PSACH v.1.0 PSACH 24VAC/6A/1x6A HERMETIC AC power supply for CCTV

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

ST Series POWER SUPPLIES USER INSTRUCTIONS

PSDC PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

D/N VANDAL RESISTANT 700TVL VARI-FOCAL IR DOME CAMERA CMR6082X/6082MX3.6 N/P CMR6086X/6086MX3.6 N/P

2013 Wireless Video Intercom INSTALLATION GUIDE

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

Operating Instructions

HCR3.2/.. Chipcard reader HOTEL SOLUTION

Contents. Safety Warnings... 1

Technical Information RIA14

Series 8146/5-V37 and Series 8150/5-V37

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

MIC-WKT and MIC-WKT-IR

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 8 mm

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

EKOS Cart. Instructions for Use

SNQ-60x0-320 Series Data Center Switch. Quick Installation Guide

CONTENTS. 1. CE DECLARATION OF CONFORMITY FOR MACHINES pag DESCRIPTION pag TECHNICAL SPECIFICATIONS pag INSTALLATION pag.

Safety instructions VEGADIS DIS81.CEIA/V****

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

LUCCI AIRFUSION QUEST II CEILING FAN

RUST ELECTRONICS LTD. Remote Switching Unit RCU-O4

EBDSPIR-PRM, EBDSPIR-PRM-IP

Operating Instructions Bedienungsanleitung Mode d emploi

Transcription:

SPARTAN Floodlight Range Installation Guide CML13ATEX3007 IEC Ex CML14.0001 This installation guide provides instructions for installing the Infra-Red and White-Light SPARTAN SPX series of explosion protected floodlights. Text in Bold is specific for emergency variants Overview 1 Safety Instructions 2 Installation 3 Maintenance 4 Technical Specification 5 Trouble Shooting 910-M-0094 Rev D Important information The SPARTAN series of explosion protected floodlights are specialist devices, certified for use in specific operating environments. The units must be installed in accordance with these instructions, must be correctly certified for the specific operating environment and must be installed by suitably qualified personnel. Emergency floodlights will require the fuse to be reconnected upon installation and the floodlight subjected to three 24 hour charge/discharge cycles to bring the battery up to peak capacity. If you have any queries about the installation or the certification of the unit please contact Raytec for immediate assistance and advice.

1. Safety instructions 1. Read this leaflet carefully before commencing to install the SPARTAN unit and retain it for future use. Installation can only be carried out by suitably qualified personnel. 2. Check the certification to ensure that the mains supply and the ambient temperature present is suitable for the unit being installed. 3. If the SPARTAN unit is to be installed in areas of high vibration, please consult with Raytec. 4. The SPARTAN unit housing is constructed from marine grade aluminium and toughened glass. The end user must ensure that these materials are suitable for the environment the SPARTAN unit will be installed in; Zone 1 and Zone 2 Hazardous areas. 5. Check certification nameplate on side of floodlight to ascertain type of threaded cable entry on the luminaire. Select suitably certified ATEX/IEC Ex cable glands and stopper plugs, these must be parallel thread, have a minium of 5 full thread engagement and be of a medium/fine tolerance to ISO965-1 and ISO965-3. The cable entry devices selected must maintain the IP rating of the luminaire 6. The incoming mains cable should not exceed a temperature rise of 20 C above the ambient conditions; select suitable cable.! 1.5m Isolate mains before removing cover Install in a well ventilated area Do not continually stare at lamp 2 www.rayteccctv.com UK / Europe Tel: +44 (0) 1670 520055

2. Installation Mounting SPARTAN Unit 1. To meet the requirements of certification a MINIMUM of 2 fixing points must be used, the fixing points must be suitable for the conditions of use. Spartan 12 Floodlight Spartan 24 (Emergency Variant Shown) UK / Europe Tel: +44 (0) 1670 520055 www.rayteccctv.com 3

Spartan 48 2. The unit may have been supplied with an integrated photocells. Care should be taken when positioning the unit to ensure the sensors are not shielded, is not pointing directly at another light source and is monitoring the general, prevailing light conditions. 3. The SPARTAN floodlight and the mounting bracket is supplied together as a unit. The bolts in the side of the housing shall be removed and used to secure the bracket to the SPARTAN housing, the bracket can be attached in the top or bottom position depending on the mounting application, where possible the cable glands should be kept to the bottom of the floodlight. It is very important that the red fibre washers are fitted between the SPARTAN housing and the mounting bracket. The unit must be aligned first before securing the bracket, on SPARTAN 24 and 48 units a locking screw is provided to lock the luminaire at various angles, the unit can be mounted horizontally or vertically allowing the unit to point up/down or left/right. 4 www.rayteccctv.com UK / Europe Tel: +44 (0) 1670 520055

Typical wiring diagram standard luminaires Typical wiring diagram emergency luminaires UK / Europe Tel: +44 (0) 1670 520055 www.rayteccctv.com 5

4. Wire the Mains cable into the terminal block. Provision has been made for this and identified as the E (Earth), L (Live), Ls (Live switched) and N (Neutral) terminals. There are two pairs of contacts for each of these to facilitate a mains cable that can be looped in and out of the unit. The Ls terminals on a standard unit is not electrically connected but allows them to be used on the same circuits as emergency floodlights. 5. Installer should earth the unit separately an internal and external earth point are provided as standard. 6. Connect wires to mains supply. 7. If the unit is opened for any reason, disconnect mains On emergency luminaires there may be more than one mains supply. 8. All SPARTAN floodlights have terminal blocks suitable for looping 4mm2 cable, only one cable should be connected to each terminal block connection. 9. Emergency SPARTAN floodlights may have a single green LED fitted adjacent to the incoming cable glands, when illuminated the green LED indicates that the emergency system is healthy. 10. The battery fuse located in the power supply lid on emergency variants is disconnected after final manufacturing testing. When installing the floodlight the battery fuse will need to be reconnected and the unit charged for 24 hours and then discharged (repeated 3 times) to bring the battery up to peak capacity. 11. If a 4 core cable is used on emergency luminaires L, Ls, N and E the link cable at the front of the terminal block between L and Ls should be removed. 12. During emergency operation the light output and duration will be determined by the variant purchased. 6 www.rayteccctv.com UK / Europe Tel: +44 (0) 1670 520055

3. Maintenance 1. It is essential that all SPARTAN units are maintained in accordance with the requirements of the EN60079-17standard: (Electrical apparatus for explosive gas atmospheres other than mines). 2. IMPORTANT. No modifications are permitted to the unit, all spare parts must be purchased from the manufacturer, unauthorized modifications or spare parts will invalidate certification and make the equipment dangerous. 3. Isolate the SPARTAN unit from the mains supply and allow to cool before carrying out any maintenance work. 4. In the unlikely event of a number of LED s failing, the light engine assembly must be replaced. This is achieved by tilting the luminaire so that the LEDs are pointing upwards, removing the power supply cover, disconnect the white and violet cable to each power supply, remove the two M8 bolts at the rear of the casting, release the safety cable and pull the light engine assembly clear. Re fitting a light engine is a reversal of the above procedure. 5. The unit has 2 independent power supplies, in the event that a power supply needs to be replaced the cables to the LED and mains terminal block will need to be disconnected, the four M6 bolts released the power supply can then be removed. Fitting a new power supply is a reversal of the above procedure, please note that the power supplies are left handed or right handed and the correct variant will need to be ordered/fitted 6. Disposal of packaging, SPARTAN unit and old LED assemblies should be carried out in accordance with national regulations. UK / Europe Tel: +44 (0) 1670 520055 www.rayteccctv.com 7

4. Technical Specification Spartan 12 Spartan 24 Spartan 48 Input Voltage 110-254V AC Consumption 30W max 60W max 120W max Consumption (Emergency variant) N/A 65W max 125W max Power Factor >0.95 Mains Frequency IP Rating 50/60Hz IP66/67 Weight Environment 5kg (11lbs) 9.5kg (20.9lbs) 19kg (41.9lbs) Weight Environment (Emergency variant) Dimensions Dimensions ATEX and IECEx Rating N/A 11.5kg (25.3lbs) 21kg (46.3lbs) See previous pages for line diagrams See below Protection/Certification II 2 GD Ex em IIC T4 or T5 Gb Ta -52 C to +55 C or II 2 GD Ex em IIC T6 Gb Ta -52 C to +48 C Ex tb IIIC T82 C Db IP66 & IP67 Ta = -52 C to +55 C 110V to 254V AC ONLY 8 www.rayteccctv.com UK / Europe Tel: +44 (0) 1670 520055

5. Trouble Shooting 1. Ensure the two LED boards are correctly wired to terminal block. White to White : Violet to Violet 2. Ensure Mains input is correctly connected. 3. Ensure Mains Input is turned on at the source 4. On emergency variants check fuse to ensure it has not blown 5. If LED panel fails to light is it possible to identify if problem is with LED panel or power supply by swapping LED cables to opposite power supply to help identify problem. *For emergency variants add EM to the end of above codes (not available for FL12) UK / Europe Tel: +44 (0) 1670 520055 www.rayteccctv.com 9

Spartan: White Light Part Code Description Max Lighting Distance* SPX-FL12-W-1010 Spartan Flood, 12 LED, White-Light, 10 x10 93m SPX-FL12-W-3030 Spartan Flood, 12 LED, White-Light, 30 x30 46m SPX-FL12-W-5050 Spartan Flood, 12 LED, White-Light, 50 x50 33m SPX-FL12-W-120120 Spartan Flood, 12 LED, White-Light, 120 x120 15m SPX-FL24-W-1010 Spartan Flood, 24 LED, White-Light, 10 x10 132m SPX-FL24-W-3030 Spartan Flood, 24 LED, White-Light, 30 x30 64m SPX-FL24-W-5050 Spartan Flood, 24 LED, White-Light, 50 x50 46m SPX-FL24-W-120120 Spartan Flood, 24 LED, White-Light, 120 x120 20m SPX-FL48-W-1010 Spartan Flood, 48 LED, White-Light, 10 x10 187m SPX-FL48-W-3030 Spartan Flood, 48 LED, White-Light, 30 x30 91m SPX-FL48-W-5050 Spartan Flood, 48 LED, White-Light, 50 x50 65m SPX-FL48-W-120120 Spartan Flood, 48 LED, White-Light, 120 x120 28m For emergency variants add -EM to the end of above codes (not available for FL12) For photocell variants add -PC to the end of the above codes *CCTV Camera use 10 www.rayteccctv.com UK / Europe Tel: +44 (0) 1670 520055

Spartan: Infra-red Part Code Description Max Lighting Distance* SPX-FL12-I-1010 Spartan Flood, 12 LED, Infra-Red, 10 x10 230m SPX-FL12-I-3030 Spartan Flood, 12 LED, Infra-Red, 30 x30 112m SPX-FL12-I-5050 Spartan Flood, 12 LED, Infra-Red, 50 x50 80m SPX-FL12-I-120120 Spartan Flood, 12 LED, Infra-Red, 120 x120 52m SPX-FL24-I-1010 Spartan Flood, 24 LED, Infra-Red, 10 x10 325m SPX-FL24-I-3030 Spartan Flood, 24 LED, Infra-Red, 30 x30 158m SPX-FL24-I-5050 Spartan Flood, 24 LED, Infra-Red, 50 x50 113m SPX-FL24-I-120120 Spartan Flood, 24 LED, Infra-Red, 120 x120 73m SPX-FL48-I-1010 Spartan Flood, 48 LED, Infra-Red, 10 x10 459m SPX-FL48-I-3030 Spartan Flood, 48 LED, Infra-Red, 30 x30 224m SPX-FL48-I-5050 Spartan Flood, 48 LED, Infra-Red, 50 x50 160m SPX-FL48-I-120120 Spartan Flood, 48 LED, Infra-Red, 120 x120 103m For emergency variants add -EM to the end of above codes (not available for FL12) For photocell variants add -PC to the end of the above codes *CCTV Camera use UK / Europe Tel: +44 (0) 1670 520055 www.rayteccctv.com 11

Typircal Spare Parts: 24-48 variants Part Code Description SFL-PSUL-STD-T4 SFL-PSUR-STD-T4 SFL-PSUL-EMER-T4 SFL-PSUR-EMER-TR SFL-LE-MW-1010 SFL-LE-MW-3030 SFL-LE-MW-5050 SFL-LE-MI-1010 SFL-LE-MI-3030 SFL-LE-MI-5050 W300-PSU-GASKET-MF W300-GLASS-GASKET-MF W300-LIGHTENGINE-GASKET-MF W300-GLASS-MF PSU Left hand PSU Right hand Emergency PSU Left hand Emergency PSU Right hand White LED Assembly 10x10 White LED Assembly 30x30 White LED Assembly 50x50 IR LED Assembly 10x10 IR LED Assembly 30x30 IR LED Assembly 50x50 Gasket - Power Supply Gasket - Glass Gasket - LED Glass 12 www.rayteccctv.com UK / Europe Tel: +44 (0) 1670 520055

Declaration Of Conformity With The Atex Directive 94/9/Ec Raytec Ltd. declares under our sole responsibility that the product(s) listed below conform with the relevant provisions of directive 94/9/EC of 23rd March 1994 Manufacturer Description of Equipment Raytec Ltd Unit 3, Wansbeck Business Park Rotary Parkway Ashington Northumberland NE63 8QW United Kingdom Spartan range of floodlights standard and emergency Notified Bodies Sira Certification Services (0518) Rake Lane Eccleston Chester CH4 9JN Certificate numbers Equipment Marking CML13ATEX3007 and CML14.0001 Quality Assurance Notification Sira 13 ATEX M592 IEC Ex Quality Assessment Report GB/SIR/QAR13.0018/00 II 2 GD Ex em IIC T4 or T5 Gb Ta -52 C to +55 C or II 2 GD Ex em IIC T6 Gb Ta -52 C to +48 C Ex tb IIIC T82 C Db IP66 & IP67 Ta = -52 C to +55 C 110V to 254V AC ONLY Emergency variants restricted to -20 o C UK / Europe Tel: +44 (0) 1670 520055 www.rayteccctv.com 13

Compliance with the Essential Health and Safety Requirements has been assessed by reference to the following standards - IEC 60079-0 : 2012 IEC 60079-7 : 2007 IEC 60079-18 : 2009 IEC 60079-31 : 2009 And also 89/336/EEC Electromagnetic Compatibility Signed Name Position Barry Thompson Head of Hazardous Area Division Dated Serial number 14 www.rayteccctv.com UK / Europe Tel: +44 (0) 1670 520055

UK / Europe Tel: +44 (0) 1670 520055 www.rayteccctv.com 15

UK / Europe T: +44 (0) 1670 520055 F: +44 (0) 1670 819760 sales@rayteccctv.com Americas (Toll Free) T: +1 888 505 8335 ussales@rayteccctv.com SP/14/8.1 www.rayteccctv.com