RF SYSTEM FOR VEPP-5 DAMPING RING



Similar documents
14.5GHZ 2.2KW CW GENERATOR. GKP 22KP 14.5GHz WR62 3x400V

CAVITY DESIGN REPORT

E. K. A. ADVANCED PHYSICS LABORATORY PHYSICS 3081, 4051 NUCLEAR MAGNETIC RESONANCE

FIVE PROJECTS OF HIGH RF POWER INPUT COUPLERS & WINDOWS FOR SRF ACCELERATORS*

APPLICATION NOTE ULTRASONIC CERAMIC TRANSDUCERS

AUTOMATION OF OPERATIONS ON THE VEPP-4 CONTROL SYSTEM

Status of the Diamond Storage Ring RF Systems. Morten Jensen on behalf of Diamond Storage Ring RF Group

Application Note SAW-Components

High Power Tests of Beryllium Oxide Windows to the Lower Hybrid Current Drive Launcher in JET

1. The Slotted Line. ECE 584 Microwave Engineering Laboratory Experiments. Introduction:

RX-AM4SF Receiver. Pin-out. Connections

Impedance Matching and Matching Networks. Valentin Todorow, December, 2009

The BESSY HOM Damped Cavity with Ferrite Absorbers. Review of prototype cavity test results, taperedwaveguidesvshomogenouswaveguides

APPLICATION NOTE AP050830

C.-K. Ng. Stanford Linear Accelerator Center. and. T. Weiland. University oftechnology. FB18, Schlossgartenstr. 8. D64289, Darmstadt, Germany.

ELECTRICAL ENGINEERING ASPECTS OF RADIOTHERAPY ACCELERATORS *

Pulsed Power Engineering Diagnostics

Linac RF Commissioning with the SNS HPRF Systems

RF-thermal-structural-RF coupled analysis on the travelling wave disk-loaded accelerating structure

TOTALLY SOLID STATE NON-DIRECTIONAL RADIO BEACONS khz

LLRF. Digital RF Stabilization System

INTEGRATED CIRCUITS DATA SHEET. TDA7000 FM radio circuit. Product specification File under Integrated Circuits, IC01

RF and Microwave Accessories. CD-ROM Catalog. Find the right component for your Rohde & Schwarz test & measurement equipment

Experiment 7: Familiarization with the Network Analyzer

Oscillators. 2.0 RF Sine Wave Oscillators. Module. RF Oscillators

EMC STANDARDS STANDARDS AND STANDARD MAKING BODIES. International. International Electrotechnical Commission (IEC)

Reliability and Availability Aspects of. the IPHI Project

Broadband Push-Pull Power Amplifier Design at Microwave Frequencies

MASW T. HMIC TM PIN Diode SP2T 13 Watt Switch for TD-SCDMA Applications. Features. Functional Diagram (TOP VIEW)

GenTech Practice Questions

PHASE LENGTH MEASUREMENTS OF LARGE MICROWAVE NETWORKS* J. Weaver? and R. Alvarez

Magnetron Theory of Operation

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

DATA SHEET. TDA8560Q 2 40 W/2 Ω stereo BTL car radio power amplifier with diagnostic facility INTEGRATED CIRCUITS Jan 08

Investigations on Critical Higher Order Modes in CEBAF Upgrade Cavities

SIGNAL GENERATORS and OSCILLOSCOPE CALIBRATION

Understanding Power Impedance Supply for Optimum Decoupling

Power Supplies. 1.0 Power Supply Basics. Module

A simple RF/Microwave frequency counter

Engineering Sciences 151. Electromagnetic Communication Laboratory Assignment 3 Fall Term

Status of the HOM Damped Cavity for the Willy Wien Ring

HP 8970B Option 020. Service Manual Supplement

Anatech Electronics, Inc.

Detector Effect in Microwave Gunn Diode Oscillator with Lowfrequency Oscillator Circuit in Bias Circuit

MITSUBISHI RF MOSFET MODULE RA07H4047M

JITAI Technology Co., LTD. Your 1 st Partner. Product Catalog. Microwave Passive Device Design and Manufacture

Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies

Constructing a precision SWR meter and antenna analyzer. Mike Brink HNF, Design Technologist.

DEPARTMENT OF DEFENSE TEST METHOD STANDARD METHOD OF INSERTION LOSS MEASUREMENT

KLYSTRON TUNING PROCEDURES:

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

APPLICATION NOTES POWER DIVIDERS. Things to consider

Design and development of Configurable BPM readout system for ILSF

A Practical Guide to Free Energy Devices

W-band vector network analyzer based on an audio lock-in amplifier * Abstract

Standex-Meder Electronics. Custom Engineered Solutions for Tomorrow

Research RF Sputtering Packages

Automotive Sensor Simulator. Automotive sensor simulator. Operating manual. AutoSim

A Practical Guide to Free Energy Devices

Microwave Components. J & N Microwave and Engineering. Product Catalogue 2010 Version 2.0

DATA SHEET. TDA1510AQ 24 W BTL or 2 x 12 W stereo car radio power amplifier INTEGRATED CIRCUITS

INFRARED MONITORING OF 110 GHz GYROTRON WINDOWS AT DIII D

The W5JCK Guide to the Mathematic Equations Required for the Amateur Extra Class Exam

HIGH CURRENT OPERATION OF THE ACSI TR30 CYCLOTRON

Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation

Application Note AN:005. FPA Printed Circuit Board Layout Guidelines. Introduction Contents. The Importance of Board Layout

Application Note Noise Frequently Asked Questions

MSAN-001 X-Band Microwave Motion Sensor Module Application Note

NUCLEAR MAGNETIC RESONANCE. Advanced Laboratory, Physics 407, University of Wisconsin Madison, Wisconsin 53706

1. INTRODUCTION. There are different frequency bans according to the range of frequencies shown: 1.1 Electromagnetic Spectrum

Activities at the University of Frankfurt (IAP)

MYRRHA Injector Design

Informe Técnico IT - CDT

A1000 Cheat Sheet (Open Loop Vector)

Shielding Effectiveness Test Method. Harbour s LL, SB, and SS Coaxial Cables. Designs for Improved Shielding Effectiveness

Current Probes. User Manual

The design and performance of Static Var Compensators for particle accelerators

LOW LOSS CABLE PAG. 1

Application Note. So You Need to Measure Some Inductors?

Clamp Filters that Suppress Emission Noise Provide Immunity Against Surge Noise

RF Network Analyzer Basics

Coupling Impedance of SIS18 and SIS100 beampipe CERN-GSI-Webmeeting

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

Methods of plasma generation and plasma sources

APSYN420A/B Specification GHz Low Phase Noise Synthesizer

High-ohmic/high-voltage resistors

MEASUREMENT SET-UP FOR TRAPS

An equivalent circuit of a loop antenna.

10 Project Costs and Schedule

PRECISION CAPACITOR CHARGING SWITCHING POWER SUPPLIES

Ferroxcube. For more information on Product Status Definitions, see page Sep CBW625

MAINTENANCE & ADJUSTMENT

Introduction to Receivers

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Digital vs. Analogue Control Systems

Impedance 50 (75 connectors via adapters)

3-5 Ka-band High Power Multi-port Amplifier (MPA)

Technical Note #3. Error Amplifier Design and Applications. Introduction

AMI MASCHINENBAU-KOLLOQUIUM

unit : mm 3067-DIP24S

Transcription:

Ó³ Ÿ. 2006.. 3, º 7(136).. 60Ä64 Š 621.384.634.14 RF SYSTEM FOR VEPP-5 DAMPING RING Ye. Gusev, N. Kot, S. Krutikhin, I. Kuptsov, G. Kurkin, I. Makarov, N. Matyash, L. Mironenko, S. Motygin, V. Osipov, G. Ostreiko, V. Petrov, A. Popov, E. Rotov, I. Sedlyarov 1, G. Serdobintsev, A. Shteinke, V. Tarnetsky, A. Frolov, K. Chernov, V. Volkov Budker Institute of Nuclear Physics, Novosibirsk, Russia The paper presents the RF system of VEPP-5 damping ring created at BINP, Novosibirsk. The RF system operates at 700 MHz and consists of the generator based on KU-393 klystron, transmitting waveguide with wave-to-coax adapters, accelerating cavity, and control system. Cavity HOMs are damped with resistive loads to eliminate the beam instability. Parameters and results of cold measurements and high-power-level tests are presented. É ² - É ³ ±μ É ²Ö-μ̲ É ²Ö ²Ö -5, μ Ö ˆ É ÉÊÉ Ö μ Ë ± ³. ƒ. ˆ. Ê ± ( μ μ ±). - É ³ μé É Î ÉμÉ 700 ŒƒÍ μ Éμ É Éμ ±² É μ Š -393, ÕÐ μ μ² μ μ ±μ ± ²Ó μ- μ² μ μ Ò³ Ìμ ³, Ê ±μ ÖÕÐ μ μ Éμ É ³Ò Ê ² Ö ±μ É μ²ö. ²Ö Ê É Ö Êαμ μ Ê Éμ Î μ É Ò Ï ³μ Ò μ Éμ μ ² Ò μ³μðóõ É ÒÌ Ê μ±. Ò ³ É Ò Ê²ÓÉ ÉÒ Ìμ²μ ÒÌ ³ μ ÖÎ Ì ÒÉ - É ³Ò. INTRODUCTION The damping ring is designed to store and to cool the 510 MeV electron and positron bunches with a number of particles of 2 10 10 [1]. The preinjector is a 510 MeV linac (operating at 2856 MHz). The RF-system parameters are deˇned by the requirements to obtain short- and high-power bunches in the damping ring. It is achieved by choosing large accelerating voltage amplitude and high RF ratio Å 700 MHz that corresponds to the 64th harmonics of the particle revolution frequency. The RF-system block diagram is shown in Fig. 1. It consists of RF generator, circulator, waveguide section, RF cavity, and control system. 1. RF GENERATOR AND WAVEGUIDE SECTION The 100 kw klystron KU-393 serves as RF-power source. Obtained parameters of klystron generator are listed in Table 1. The klystron is fed from the 200 kw six-phase rectiˇer. The voltage is controlled by thyristors. A resistor is inserted into the circuit to prevent the klystron damage during discharges. The klystron solenoid consists of ˇve coils, each of them is fed from a separate source. 1 E-mail: I.K.Sedlyarov@inp.nsk.su

RF System for VEPP-5 Damping Ring 61 Fig. 1. RF-system block diagram Table 1. RF-generator parameters Frequency, MHz 700 Voltage, kv 27 Beam current, A 5.4 Output power, kw 65 Efˇciency, % 45 Gain, db 46 Table 2. Circulator parameters Feedthrough power, kw 100 Loss power, db 0.3 Input VSWR < 1.2 Dissipated power, kw < 15 The RF power is transmitted through the aluminium rectangular waveguide (292.1 146.05 mm). The waveguide attenuation is 0.0035 db/m. The klystron and cavity are connected to the waveguide via wave-to-coax connectors with VSWR less than 1.05 at the operating frequency. The feedthrough power is measured with directional couplers. The Y-circulator is installed into the waveguide section to uncouple the klystron from the cavity. The Y-circulator design parameters are listed in Table 2. 2. RF CAVITY A cylindrical copper cavity with small protrusions in the aperture area is made by brazing the discs to the sidewall. At present, the cavity is installed into the damping ring (Fig. 2). The RF power is transmitted to the cavity through 75-Ω coaxial feeder. At the operating frequency, VSWR of the wave-to-coax adapter is better than 1.15. The inductive power input is used. A cylindrical window made of 22XC ceramics isolates the cavity vacuum volume from the atmosphere. The frequency is tuned by the contact-free plunger. The cavity walls and plunger are cooled by water. Power input and plunger vacuum parts are coated with TiN to suppress the RF discharge. The cavity HOMs were heavily loaded to provide phase stability of short bunches in the ring. Coupling with HOMs is provided by three waveguides, uniformly azimuthally

62 Gusev Ye. et al. Fig. 2. RF cavity in the damping ring Table 3. RF-cavity parameters Operating frequency, MHz 700 Shunt impedance, MΩ 4 Q factor 2000 Transit time factor 0.748 Accelerating voltage, kv 200 Frequency tuning, MHz 1.6 distributed, with a cutoff frequency of 908 MHz. The HOMs' energy is distributed via wave-to-coax adapters into these waveguides and then to the external loads. Within the range of 0.95Ä2.2 GHz, VSWR of the adapters is less than 2 and measured Q factors of the majority of HOMs do not exceed 100. The Q factor of the operating mode E 010 decreased by 7.5% during connection of the loads. The main cavity parameters are listed in Table 3. The RF-system elements are also described in [2, 3]. 3. CONTROL SYSTEM A simpliˇed block diagram of the RF system is shown in Fig. 3. The Master Oscillator is a source of reference signals and the driver signal for the RF power ampliˇer. There is a feedback loop to control the RF voltage amplitude at the cavity gap. The RF signal V cav from the cavity sampling loop comes to the amplitude detector of the Modulator. Output of the amplitude detector is connected to a differential ampliˇer. The other input of the ampliˇer has a signal of DC voltage from DAC controlled by a computer. Output signal from the differential ampliˇer controls the Gain Control stage of the RF-power ampliˇer. Gain of the differential ampliˇer is large enough, so the cavity gap voltage is kept proportional to the signal from DAC. The other feedback loop controls the phase of the RF-cavity voltage in relation to the reference signal of the Master Oscillator. Phase difference between signals V cav and that of the reference signal is measured by the Phase Meter 1. Output signal of the phase meter controls the electronic Phase Shifter 1 installed into the RF-power ampliˇer channel. It is possible to set initially the cavity voltage phase with the Phase Shifter 2.

RF System for VEPP-5 Damping Ring 63 Fig. 3. RF control system block diagram The time constant of the two feedback loops is about 300 s and the amplitude and phase modulation index of the RF-cavity voltage is less than 2 10 3. The frequency of the RF-cavity fundamental mode should be constantly tuned to the resonance to compensate the cavity temperature alterations due to the changes in the cooling water temperature or operating regime. The Phase Meter 2 measures the phase difference between the RF signal V cav and the signal I coup which is proportional to the current in the RF-cavity coupling loop. The phase meter output signal drives the tuner mechanism through the Servo ampliˇer. Time constant of the feedback loop is about 200 ms, the tuning error is less than 5. The Interlock module switches off the Modulator in emergency condition. The driver RF signal for the klystron is removed in this case. Control and monitoring of the RF system from computer are made through the CANBUS serial network. 4. RESULTS OF RF SYSTEM TESTS The RF-system tests were carried out in three stages. Firstly, the klystron generator was connected to the matched watercooled load via the waveguide section. The maximal power of 65 kw has been obtained in a continuous regime. At the second stage, the cavity was assembled, heated for 24 h at 150 C at the stand, and connected to the waveguide. Without RF power, the ion pump of 160 l/s productivity provided 10 9 Torr vacuum. The RF conditioning was started in the pulsed mode. This mode limited the discharge energy and allowed the pressure to be maintained at the required level (10 9 Torr) by varying the off-duty factor. After that, the conditioning was carried out in continuous regime; the voltage range of multipactor appearance was passed in 2 h, accelerating voltage of 225 kv was obtained on the cavity at 10 8 Torr vacuum. The coupling constant of the power input was insufˇcient, so a transformer was installed before the power input. At the third stage, a new power input with enlarged loop was installed. The cavity was installed into the damping ring and isolated from its chamber by two vacuum valves. The 2 10 9 Torr vacuum was obtained in the cavity, so it was decided to carry out RF tests without preheating.

64 Gusev Ye. et al. Multipactor area was observed in the accelerating voltage range of 22Ä60 kv. After 5-hour conditioning in the pulsed mode, continuous regime was activated and multipactor range was easily passed at rapid voltage rise. Multipactor range conditioning for 15 h in continuous regime led to vacuum improvement from 1.6 10 6 to 2.7 10 7 Torr in this area. The conditioning will be continued. In continuous regime, accelerating voltage of 225 kv was obtained for a long time at 11.5 kw power dissipated in the cavity and 10 8 Torr vacuum. At resonant tuning, the reected wave is rather small (VSWR = 1.19) and cavity voltage is determined by measured incident wave power and cavity parameters. The maximal heating (up to 60 C) was observed at the cavity sidewall near the frequency turning ange. The temperature frequency deviation was 150 khz. The klystron generator operated at the anode voltage of 20.2 kv and gain of about 46 db. CONCLUSION As a result of low- and high-power-level tests of the RF system, the parameters which provided the damping ring operating were obtained. The voltage range at which the multipactor in the cavity is observed lies below the accelerating voltages of 100Ä150 kv which are required for beam capturing into the ring. The multipactor is easily passed at rapid voltage increase. The RF system operating with the beam is planned for the end of 2005. REFERENCES 1. Dikansky N. S. et al. // Proc. of EPAC'94, London, July 1, 1994. P. 482Ä484. 2. Alinovsky N. et al. // Proc. of EPAC'98, Stockholm, June 22Ä26, 1998. V. 3. P. 1799Ä1803; IEEE. 1999. 3. Bolkhovityanov D. et al. // Proc. of XVII Workshop on Charged Part. Acc., Protvino, 2000. V. 1. P. 51Ä54.