Waveguide Access Point WGA631. Product Guide



Similar documents
Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

Telephone- and leased line modem for industrial applications TD-36

Remote Monitoring and REC 501 Control Unit Product Guide

Foxboro Evo Process Automation System

Voltage Regulator SPAU 341 C. Product Guide

Rack mounted telephone- and leased line modem for industrial applications

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Communication Unit 560CMU05 Data sheet

Disturbance Recoder SPCR 8C27. Product Guide

T200, PTP/IEEE 1588 Grandmaster Clock and

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

TX OPEN RS232/485 module

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

HCR3.2/.. Chipcard reader HOTEL SOLUTION

15 Series - Electronic step relay and dimmer. Features SERIE

PHOENIX CONTACT - 03/2007

Analog signal converters CC-E I/I Current / current isolators

Rated Power(W) 8W 2. EG-LED W 3. EG-LED W

TEST REPORT EN (1997) +A1 (2001)

IntesisBox Modbus Server SAMSUNG Air Conditioners

Three-phase monitoring relay CM-PFE

KNX Panasonic Air Conditioners

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

Indoor / Outdoor Antenna

Relion 605 series. Self-powered feeder protection REJ603 Product Guide

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

C13 User Manual Document ID: 2CMC486004M0201 Revision: A

HEOL-N103-OBD, GPS/GPRS Tracking Module with On Board Diagnostic

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

ISIO 200. Binary Input/Output (I/O) Terminal with IEC Interface

Communicate and view data from meters with one simple device

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

AC 800M. EtherNet/IP DeviceNet Linking Device LD 800DN. Power and productivity for a better world TM SP1134

RM4TG20 three-phase network control relay RM4-T - range V

Disclaimers. Important Notice

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

Modbus Server SAMSUNG Air Conditioners

Operating Manual UWAPS-TINY Series

IntesisBox Modbus Server Fidelio IP

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Capacitor Protection Relay SPAJ 160 C. Product Guide

Quick Connect. quick - simple - efficient.

USB-to-Data Highway Plus Cable

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Gain energy insight and control with PowerLogic. PowerLogic EGX300 integrated gateway-server

38 Series - Relay interface modules A

HP Server Console Switch with Virtual Media Overview

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

Version Date Author Description Jpo First version Jpo FET output descriptions made clearer

Trip circuit supervision relay. Type RXTCS

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

IntesisBox KNX Modbus TCP master


Storage System. Planning Checklist. EC E1, First Edition

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

Test Report #: Date: April 8, 2005

EMR. WAN Compact Router for Industrial Ethernet Networks. A secure access to Ethernet industrial networks making use of the public operator networks

1756 ControlLogix Chassis Specifications

Test Report. Prepared for: Technologic Systems, Inc. Model: TS-8820

Application Server V240 Platform

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

EN v1.2.1 TEST REPORT FOR ag/Draft n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

ORION TELECOM NETWORKS INC. T1

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

QuickSpecs. HP IP Console Switch with Virtual Media Overview

Huawei NE5000E 400Gbps Flexible Line Processing Unit

C24-CAMANL Video Server/Encoder

OZS Web server. For LPB/BSB plants

Relés e Contatores de Estado Sólido SIRIUS

AMIS. Automated Metering and Information System. Integration of meters from other manufacturers

TX2123 RS485 TO ETHERNET ADAPTOR

38 Series - Relay interface modules A

PRO 5000 CPE 1D Quick Installation Guide

The Intel NetStructure SIU520 Signaling Interface

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Arc Protection Relay REA 10_. Product Guide

Drayton Digistat +2RF/+3RF

PE310G4BPi40-T Quad port Copper 10 Gigabit Ethernet PCI Express Bypass Server Intel based

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version ( )

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

VCL-PRI ISDN VALIANT COMMUNICATIONS LIMITED. Primary Rate (Euro-ISDN) Multiplexer. Product Brochure & Data Sheet

Manual. Simrad StructureScan LSS-1 Sonar Module. English

xepi 2 Installation Guide Diagnostic Unit and Configuration Interface Doc. Version 4.0 English

Application/Connection Examples

Transcription:

Waveguide Access Point Product Guide

Waveguide Access Point Contents 1. Description............................ 3 2. Application............................ 3 3. Technical data... 4 4. Physical interfaces...................... 7 5. Mounting methods...................... 7 6. Ordering data.......................... 8 7. Accessories and ordering data............. 8 8. Tools................................. 9 9. Terminal diagram... 10 Disclaimer The information in this document is subject to change without notice and should not be construed as a commitment by ABB Oy. ABB Oy assumes no responsibility for any errors that may appear in this document. Copyright 2009 ABB Oy All rights reserved. Trademarks ABB is a registered trademark of ABB Group. All other brand or product names mentioned in this document may be trademarks or registered trademarks of their respective holders. 2 ABB

Waveguide Access Point 1. Description WaveGuide Access Point is a communication adapter for wireless local area networks (LANs) using waveguide technology. The adapters are attached to the waveguide tubes of the switchgear to provide communication for protection and control devices supporting the Ethernet based IEC 61850-8-1 protocol including the standard s GOOSE services. 2. Application Issued: June 2009 Revision: B / 23 June 2009 mounting and integration of the waveguide tube in the switchgear is done by the switchgear manufacturer. The unit is equipped with three galvanic RJ-45 interfaces which enable the connection of up to three IEDs located in the same low voltage compartment to one unit. However, only one coaxial antenna cable is needed to connect the to the waveguide tube. Furthermore, does not require any communication mapping contributes to a reduced need for wiring between switchgear and speeds up the commissioning phase of the switchgear. The communication system can be extended if needed by extending the waveguide tube and adding units. Fig. 1 application example enables in combination with the waveguide tube interference-free wireless Ethernet communication between IEDs in switchgear. acts as a converter between the galvanic connection and the wireless 5 GHz signal for the WaveGuide IEC 61850 station bus communication. The unit can be used in both gas (GIS) and air (AIS) insulated switchgear. The unit is placed next to the IED in the low voltage compartment of the switchgear. The NCC Station computer/ Gateway IEC 60870-5-101 or IEC 60870-5-104 IEC 61850-8-1 Waveguide IEEE802.11a IEC 61850-8-1 ABB 3

Waveguide Access Point Protection 3. Technical data Dimensions Width Height Depth Weight 141.5 mm 71.0 mm 200.0 mm 1.25 kg Power supply Description U aux nominal U aux variation Power consumption Connectors Interface Value 110...230 V AC 110...220 V DC 70...110% of U n (77...253 V AC) 70...110% of U n (77...242 V DC) ~5 W Type Waveguide connector R-SMA cable connector 1) Ethernet connector RJ-45 galvanic LAN connector 1) For example, Telegärtner R-SMA, J01150R0001 Communication Protocol type IEC 61850 Degree of protection by enclosure Front side IP 20 Top IP 40 Rear side IP 40 4 ABB

Waveguide Access Point Environmental conditions and tests Environmental conditions Operating temperature range -10...+55ºC (continuous) Transport and storage temperature range According to IEC 60068-2-48 Test values: -20...+70 C Environmental tests Dry heat test (humidity <50%) According to IEC 60068-2-2 Test values: 96 h at +65ºC Start-up at +55ºC Dry cold test According to IEC 60068-2-1 Test values: 96 h at -40ºC Start-up at -40ºC Electromagnetic compatibility tests Power supply module The EMC immunity test level meets the requirements listed below: 1 MHz burst disturbance test, class IV: Common mode Differential mode According to IEC 61000-4-4 4 kv 2 kv Fast transient disturbance tests: According to IEC 61000-4-4 4 kv Surge immunity test: According to IEC 61000-4-5 4 kv, line-to-earth 2 kv, line-to-line Electromagnetic emission tests: Conducted, RF emission (mains terminal) Radiated RF emission According to EN 55011 EN 55011 (0.15...30 MHz) IEC 61000-4-3 (80 MHz..,.1 GHz, 10 V/m) Enclosure The EMC immunity test level meets the requirements listed below: Electrostatic discharge test, class IV: For contact dischargecommon mode Differential mode Radio frequency interference tests: Conducted, common mode Radiated, amplitude-modulated According to IEC 61000-4-4 +/- 8 kv +/- 8 kv According to IEC 61000-4-6 10 V (rms), f = 150 khz...80 MHz According to IEC 61000-4-3 10 V/m (rms), f = 80...3000 MHz ABB 5

Waveguide Access Point Protection Ethernet and WGA port The EMC immunity test level meets the requirements listed below: Fast transient disturbance test, class III According to IEC 61000-4-4 2 kv Radio frequency interference tests: Conducted, common mode According to IEC 61000-4-6 and IEC 60255-22-6 10 V (rms), f = 150 khz...80 MHz Mechanical tests Vibration tests (sinusoidal) According to DNV Standard for Certification No. 2.4, April 2001 EMC compliance Complies with the EMC directive 89/336/EEC Product safety Complies with the LV directive 73/23/EEC RoHS compliance Complies with the RoHS directive 2002/95/EC System requirements for the WINBOX tool Hardware requirements 10 MB free hard disk space RJ-45 interface for configuration with WINBOX RS-232 interface for configuration via script file download. Supported operating systems Microsoft Windows 2000, SP4 or later Microsoft XP Professional Edition, SP2 or later Microsoft Windows Server 2003 Default IP address configuration Description Value LAN-IP1 192.168.0.1 LAN-IP2 192.168.0.2 LAN-IP3 192.168.0.3 WLAN-IP 192.168.1.1 6 ABB

Waveguide Access Point 4. Physical interfaces 1. RJ-45 Ethernet connector 1 2. Service port 3. RJ-45 Ethernet connector 2 4. RJ-45 Ethernet connector 3 5. Earthing screw 6. Coaxial waveguide interface 7. Auxiliary power supply connector 8. Power-up LED 9. Start-up LED 10. LAN and diagnostic LEDs 11. DIN rail mounting 4 3 2 1 10 8 9 11 7 6 5 Fig. 2 Physical interfaces 5. Mounting methods WGA61 can by means of a standardized (EN 50022, DIN 46277, BS 5584) 35 mm top-hat mounting rail be mounted either horizontally or vertically in the low voltage compartment of the switchgear. However, horizontal mounting is recommended as it offers the best passive cooling of the unit. The clamps on the backside of enable disassembly of the unit if needed. The unit should be placed near the IED in order to minimize the length of the CAT 7 cable and the coaxial antenna cable. Fig. 3 Horizontal mounting in the low-voltage compartment of the switchgear ABB 7

Waveguide Access Point Protection 6. Selection and ordering data Use the ordering key information in Fig. 4 to generate the order number when ordering. The type and serial number label identifies the Waveguide Access Point unit. The label is placed the upper part of the unit. The order number consists of a string of codes generated from the hardware modules of the unit. W G A 6 3 1 H # DESCRIPTION 1 Ethernet connectors 3 RJ45 connectors 3 2 Ports 1 5 GHz port 1 3 Power supply 110...230 V AC, 110...220 V DC H Fig. 4 Ordering key 7. Accessories and ordering data The delivery of the only includes the actual communications adapter. Accessories like cables, antennas and connectors are not supplied by ABB. Furthermore, the waveguide tube that connects the switchgear and enables interference free wireless communication must be produced and integrated in the switchgear by the switchgear manufacturers. Waveguide tube drawings can be downloaded from the inside.abb.com/substationautomation web portal. Waveguide tube drawings Document Waveguide tube - Variants for different switchgear types Waveguide tube End cover Waveguide tube - Details of the hole for the antenna interface Document ID 1VB8001475 1VB8001476 1VB8001478 8 ABB

Waveguide Access Point 8. Tools All units are delivered with the same set of preconfigured IP addresses for the galvanic RJ-45 interfaces and the wireless coaxial interface. The IP addresses can be changed using the Winbox configuration tool. Winbox further enables the configuration of as either a Master (AP-bridge) or a Client in slave mode (wds-slave). The Winbox tool can be downloaded from the unit s flash memory or from the inside.abb. com/substationautomation web portal. can in addition to the Winbox configuration tool be configured with the unit s RS-232 interface and a terminal program such as the open source TeraTerm software or any other RS-232 terminal program for script file download. Tools Tool Version Document ID Winbox configuration tool 1.0 1MRS756597 ABB 9

Waveguide Access Point Protection 9. Terminal diagram Fig. 5 Terminal diagram 10 ABB

ABB Oy Distribution Automation P.O. Box 699 FI-65101 VAASA, Finland Phone +358 10 22 11 Fax +358 10 22 41094 www.abb.com/substationautomation Copyright 2009 ABB. All rights reserved.