Using DHCP and XML to Transfer Files to an Intermec Mobile Computer



Similar documents
Configure the idrac Remote Access Console

SharePoint AD Information Sync Installation Instruction

Practice Fusion API Client Installation Guide for Windows

SmartSystems Reporting Services. Installation Guide

Installing Microsoft Exchange Integration for LifeSize Control

Moxa Device Manager 2.3 User s Manual

PCRecruiter Resume Inhaler

SmartSystems Foundation

Tech Tips Helpful Tips for Pelco Products

Installation Guide. . All right reserved. For more information about Specops Deploy and other Specops products, visit

IP phone services setup

Security Assertion Markup Language (SAML) Site Manager Setup

SharePoint Wiki Redirect Installation Instruction

VRC 7900/8900 Avalanche Enabler User s Manual

Abstract. These Application Notes provide information for the setup, configuration, and verification of this solution.

Professional Mailbox Software Setup Guide

Step-by-Step Setup Guide Wireless File Transmitter FTP Mode

Configuring Color Access on the WorkCentre 7120 Using Microsoft Active Directory Customer Tip

SharePoint List Filter Favorites Installation Instruction

ACP ThinManager Tech Notes ThinManager and PXE Boot

MS Windows DHCP Server Configuration

Customer Tips. Xerox Network Scanning HTTP/HTTPS Configuration using Microsoft IIS. for the user. Purpose. Background

Available Update Methods

Reference and Troubleshooting: FTP, IIS, and Firewall Information

HP Device Manager 4.6

MODEM AND DIAL-UP. Installation/Configuration (Windows 95/98/Me/NT/2000/XP)

Step-by-Step Setup Guide Wireless File Transmitter FTP Mode

Professional Mailbox Software Setup Guide

FTP, IIS, and Firewall Reference and Troubleshooting

Active Directory Management. Agent Deployment Guide

StarWind iscsi SAN Software: Installing StarWind on Windows Server 2008 R2 Server Core

Customer Tips. Configuring Color Access on the WorkCentre 7328/7335/7345 using Windows Active Directory. for the user. Overview

SOA Software API Gateway Appliance 7.1.x Administration Guide

Sharp Remote Device Manager (SRDM) Server Software Setup Guide

AXIS 70U - Using Scan-to-File

Using SQL Reporting Services with Amicus

Cascaded Lookup 5.0 User Guide

Administration Guide. . All right reserved. For more information about Specops Deploy and other Specops products, visit

DocuSign for SharePoint

If you have questions or find errors in the guide, please, contact us under the following address:

Chapter 15: Forms. User Guide. 1 P a g e

How To Configure A Cisco Unified Ip Phone On A Cnet Box On A Microsoft Powerbook 2.5 (Powerbook) On A Mini Ip Phone (Mini Ip) On An Ip Phone With A Mini Cell Phone (Microsoft Power

How To Backup In Cisco Uk Central And Cisco Cusd (Cisco) Cusm (Custodian) (Cusd) (Uk) (Usd).Com) (Ucs) (Cyse

Connection Broker Managing User Connections to Workstations, Blades, VDI, and More. Quick Start with Microsoft Hyper-V

Step-by-Step Setup Guide Wireless File Transmitter FTP Mode

LifeSize Control Installation Guide

TIBCO ActiveMatrix BPM Integration with Content Management Systems Software Release September 2013

Chapter 1 Configuring Internet Connectivity

Using Internet or Windows Explorer to Upload Your Site

Using FTP to update L300 Firmware

Trial environment setup. Exchange Server Archiver - 3.0

Upgrading Your Web Server from ClientBase Browser Version 2.0 or Above to Version 2.1.1

Getting Started with ESXi Embedded

Using Microsoft Expression Web to Upload Your Site

Web Proxy Auto Discovery (WPAD) Configuration Guide. Revision Warning and Disclaimer

Printer Connection Manager

Census. di Monitoring Installation User s Guide

HP Server Management Packs for Microsoft System Center Essentials User Guide

Administration Guide. . All right reserved. For more information about Specops Gpupdate and other Specops products, visit

Sage Peachtree Installation Instructions

This document summarizes the steps of deploying ActiveVOS on oracle Weblogic Platform.

Ingenious Testcraft Technical Documentation Installation Guide

Management Software. Web Browser User s Guide AT-S106. For the AT-GS950/48 Gigabit Ethernet Smart Switch. Version Rev.

Installing the ASP.NET VETtrak APIs onto IIS 5 or 6

TANDBERG MANAGEMENT SUITE 10.0

4 Networking Generators

Avaya Network Configuration Manager User Guide

Specops Command. Installation Guide

How to set up Outlook Anywhere on your home system

SharePoint Password Change & Expiration 3.0 User Guide

Administering Windows-based HP Thin Clients with System Center 2012 R2 Configuration Manager SP1

IP Phone Services Configuration

Archive Attender Version 3.5

Intellicus Enterprise Reporting and BI Platform

Network Scanner Tool R3.1. User s Guide Version

Installing SQL Express. For CribMaster 9.2 and Later

Background Deployment 3.1 (1003) Installation and Administration Guide

IP Phone Configuration and Troubleshooting Guide

Using the vcenter Orchestrator Plug-In for vsphere Auto Deploy 1.0

IBM Security QRadar Vulnerability Manager Version User Guide

Moxa Device Manager 2.0 User s Guide

Integrating LANGuardian with Active Directory

Smart Control Center. User Guide. 350 East Plumeria Drive San Jose, CA USA. November v1.0

DocAve 6 Service Pack 1 Job Monitor

User Guide. Version 3.2. Copyright Snow Software AB. All rights reserved.

ProSafe Plus Switch Utility

AcuityLink. Clinician Notifier. Software installation instructions. Software version 1.5x


Installing, Uninstalling, and Upgrading Service Monitor

By the Citrix Publications Department. Citrix Systems, Inc.

Chapter 1 Configuring Basic Connectivity

Downloading the Setup Program

IMAP and SMTP Setup in Clients

CentreWare Internet Services Setup and User Guide. Version 2.0

Network FAX Driver. Operation Guide

PageScope Router. Version 1.5. Configuration Guide

WA2262 Applied Data Science and Big Data Analytics Boot Camp for Business Analysts. Classroom Setup Guide. Web Age Solutions Inc.

Global VPN Client Getting Started Guide

CRM Migration Manager for Microsoft Dynamics CRM. User Guide

Blue Coat Security First Steps Solution for Deploying an Explicit Proxy

Transcription:

Using DHCP and XML to Transfer Files to an Intermec Mobile Computer

Introduction This document is intended for use by systems and network administrators who are responsible for the deployment of Intermec mobile computers. The reader should have basic knowledge of xml, networking, DHCP servers and device addressing, understand the network setup and configuration for DHCP servers inside your enterprise network, have access to the configuration file or application to be moved to Intermec mobile computers, and documentation of the current network settings and the DHCP server product being used before beginning. The SmartSystems client ships on Intermec mobile computers. The SmartSystems client (SSRef 3.30 and above 1 ) supports setting configuration values and loading files onto Intermec mobile computers via a DHCP server that supports vendor options. TFTP is used as the file transfer protocol to download the specified XML configuration file and any files referenced in that XML file. This feature is useful for deploying applications and/or settings to your Intermec Mobile computer. 2 computer connects to the DHCP server, the designated software will be loaded. When the Unlike a device management system, this approach to file transfer does not require a separate device management server, nor does it offer the same level of administrator interaction and control. Utilizing this file transfer approach requires administrative access to a DHCP server and the network expertise to configure the server. This feature should not be used to upgrade the operating system (or SSPB) of an Intermec mobile computer. There are other tools available to do this, such as SmartSystems Foundation. Supporting Vendor Options This document assumes a TFTP server is already configured and that the DHCP server exists but is not yet configured to use the Intermec vendor options. The following instructions explain how to define Vendor Options for SmartSystems DHCP Auto Configuration in a Microsoft Windows Server 2003 environment. 3 SmartSystems DHCP Auto Configuration uses vendor options 66 and 67 to specify a TFTP server and a file to download. 1 Available for download on the Intermec download site for specific mobile computers. 2 For more information on general programming tips and how to package, launch, and deploy applications for your Intermec computers, please see the Intermec Developer Library (IDL) Resource Kit Developer s Guide located at http://epsfiles.intermec.com/eps_files/eps_man/934-006.pdf. 3 Other DHCP servers that support Vendor Options may also be used; however, you must consult your specific DHCP Server guide for steps on how to define Vendor Classes and Vendor Options. 2

Define a Vendor Class 1. From Administrative Tools, select DHCP. 2. Select the DHCP server you want to manage. 3. From the Action menu, select Define Vendor Classes. The DHCP Vendor Classes window opens. 4. Click Add. The New Class window opens. 5. In the Display name field, enter a name describing your vendor class: for example, Intermec CN3E. This will be the vendor class that includes all Intermec CN3E computers. Each type of Intermec mobile computer has a unique Vendor Class name as listed in the table below. Note that the Vendor Class name is made up of the word Intermec, a period, and then the mobile computer s model number. The models listed in the table below are the only models supported at this time. Intermec Mobile Computer Model CN3A CN3B CN3E CV30 CK3 CK32 Vendor Class Name Intermec.CN3A Intermec.CN3B Intermec.CN3E Intermec.CV30 Intermec.CK3 Intermec.CK32 6. Position the cursor in the ASCII area of the Data Entry group and enter the vendor class name for you Intermec mobile computer model. 7. Click OK. 8. In the DHCP Vendor Classes window, click Close.

Define Vendor Class Options 1. From the Action menu, select Set Predefined Options. The Predefined Options and Values window opens. 2. Select the Vendor Class you defined above from the Option class drop-down list. 3. Click Add. The Option Type window opens. 4. Enter the following values as shown below. Name: TFTP Server Data type: String Code: 066 Description: SS TFTP Server 5. Click OK. 6. Click Add. The Option Type window opens. 7. Enter the following values as shown below. Name: AutoConfig File Data type: String Code: 067 Description: SS CN3E AutoConfig File 8. Click OK.

9. In the Predefined Options and Values window, click OK. 10. Right-click on Server Options and select Configure Options. The Server Options window opens. 11. Click the Advanced tab. 12. In the Vendor class dropdown list, select the appropriate vendor class. 13. Check the checkbox for option 066. 14. In the String value field, enter the TFTP server s IP address. 15. Click OK. 2

16. Check the checkbox for option 67. 17. In the String value field, enter the file name of the SmartSystems Auto Configuration file on the TFTP server. 18. Click Apply 19. Click OK. 3

SmartSystems XML Auto-Configuration File SmartSystems DHCP Auto-Configuration uses an XML file to specify one or more files to download onto an Intermec mobile computer. 4 To apply Intermec Settings, download a configuration file 5 to the \SmartSystems\SSConfigDir directory on the mobile computer. To install an application, download and execute the cab files on the mobile computer. Files can also simply be copied to the mobile computer The files or settings on the TFTP server are processed according to the instructions in the DHCP AutoConfig xml file when the mobile computer is booted and an IP address is applied via DHCP. Explanation of the DHCPAutoConfig XML Tags and Attributes <DHCPAutoConfig> - No Attributes <DHCPAutoConfig> SubElements <Files> No attributes <Files> Sub Elements <File> Attributes: Src (required) In URL format, this is the location to download the file from. Currently only the tftp protocol is supported for file download. Example: Src= tftp:\\filename.cab Dest (required) The destination directory and filename on the mobile computer. Example: Dest= \directory\filename.cab FileId (required) Functions as a file version. After the initial download of the file, if the value of FileId is changed, then the specified file will be downloaded and/or run on the next warm boot of the unit. If the value of FileID remains the same, then the specified file is ignored on the next warm boot of the unit. If the file on the unit is deleted or changed on the device, and the FileId did not change in the xml, then the file will not be processed. Example: FileId= 3.30.03.0390 StartIn (optional) The directory where the executable provided in the Run attribute should be started. Run (optional) Loads the specified program and executes it. Example: Run= \2577\autocab.exe CmdLine (optional) Command line for the executable provided in the Run attribute. Example: CmdLine= -FILE= \directory\filename.cab -FORCE Wait (optional) Variable that determines if processing of the file waits for the executable to be finished before continuing. true/false. Example: Wait= false 4 For more information on general programming tips and how to package, launch, and deploy applications for your Intermec computers, please see the Intermec Developer Library (IDL) Resource Kit Developer s Guide located at http://epsfiles.intermec.com/eps_files/eps_man/934-006.pdf. 5 For more information on how to create a configuration file, please see the Intermec Developer Library (IDL) Device Management Resource Kit. The Intermec Developer Library Resource Kits (IDL) are separate install kits, available at www.intermec.com/idl or from www.intermec.com/support/downloads. 4

XML File Example Remember, XML is case-sensitive; so if a file will not download, check the XML tags, attributes, and filenames for proper use of upper and lower case. This example downloads the SSRefClient cab file and the resetmeplease flag file to the Flash File Store directory on the mobile computer, extracts and installs the.cab file using the AutoCab utility, and then performs a warm boot. 6 The CN3E_DHCPAutoConfig.xml, resetmeplease.txt, and SSRefClient_WM50_ARMV4I.CAB files are already in the root directory of the TFTP server specified in the Vendor Class options of the DHCP server. <?xml version="1.0"?> <!-- This is the Intermec CN3E_DHCPAutoConfig.xml file. It is automatically downloaded to the CN3E's on the network each time they perform a warm boot. This file is placed in the root directory of the TFTP Server that is specified in the DHCP Server's "Intermec CN3E" Vendor class, option 066. This filename matches the filename specified in the DHCP Server's "Intermec CN3E" Vendor class, option 067. Any files specified in the <Files> tag are also placed in the root directory of the TFTP Server.--> <DHCPAutoConfig> <Files> <File Src="tftp:// resetmeplease.txt" Dest="\Flash File Store\ resetmeplease.txt" FileId="1.0"> </File> <File Src="tftp://SSRefClient_WM50_ARMV4I.CAB" Dest="\Flash File Store\SSRefClient_WM50_ARMV4I.CAB" FileId="3.30.03.0390" Run="\2577\autocab.exe" CmdLine="-FILE="\Flash File Store\SSRefClient_WM50_ARMV4I.CAB" -FORCE -SHOW=2 - CHKRST=1"> </File> </Files> </DHCPAutoConfig> In this example, a custom settings.xml file is downloaded to the \SmartSystems\SSConfigDir. This file sets the values of the specified Intermec Settings fields. 7 <?xml version="1.0"?> <!-- This is the Intermec CN3E_DHCPAutoConfig.xml file. It is automatically downloaded to the CN3E's on my network each time they perform a warm boot. This file is placed in the root directory of the TFTP Server that is specified in the DHCP Server's "Intermec CN3E" Vendor class, option 066. This filename matches the filename specified in my DHCP Server's "Intermec CN3E" Vendor class, option 067. Any files specified in the <Files> tag are also placed in the root directory of the TFTP Server. --> <DHCPAutoConfig> <Files> <File Src="tftp://MyCN3Settings.xml" Dest="\SmartSystems\SSConfigDir\MyCN3Settings.xml" FileId="1.4"> </File> </Files> </DHCPAutoConfig> 6 For more information on general programming tips and how to package, launch, and deploy applications for your Intermec computers, please see the Intermec Developer Library (IDL) Resource Kit Developer s Guide located at http://epsfiles.intermec.com/eps_files/eps_man/934-006.pdf. 7 For more information on how to create a configuration file, please see Using the SmartSystems API in the Intermec Developer Library (IDL) Device Management Resource Kit. The Intermec Developer Library Resource Kits (IDL) are separate install kits, available at www.intermec.com/idl or from www.intermec.com/support/downloads. 5

The following XML is the contents of the MyCN3Settings.xml file used in the example above. 8 In this example, the SmartSystems Server resides on a different subnet than the CN3, so the Associated Server IP must be manually set to the IP Address of the SmartSystems Server. Power Mode on the Radio is disabled to enhance network performance, although this increases battery usage. The Power Management profile is set to Phone and the backlight is set to always on. 9 <?xml version="1.0"?> <DevInfo Action="Set" Persist="true"> <Subsystem Name="IQueue"> <Field Name="Associated Server IP">192.168.0.5</Field> </Subsystem> <Subsystem Name="Funk Security"> <Group Name="Profile" Instance="Profile_1"> <Field Name="SSID">MyCompany</Field> <Field Name="PSMode">Disabled(CAM)</Field> <!--Power Mode= Disabled(CAM) {Continuous access mode} provides the best network performance (data throughput) but draws the most power.--> <Field Name="Association">WPA</Field> <Field Name="Encryption">TKIP</Field> <Field Name="PreSharedKey">MyPreShared</Field> </Group> </Subsystem> <Subsystem Name="Device Settings"> <Group Name="Power Management"> <Field Name="Power Profiles">1</Field> </Group> <Group Name="Display"> <Group Name="Backlight"> <Group Name="External Power"> <Field Name="Backlight turns off after">0</field> </Group> </Group> </Group> </Subsystem> </DevInfo> 8 For more information on how to create a configuration file, please see the Intermec Developer Library (IDL) Device Management Resource Kit. The Intermec Developer Library Resource Kits (IDL) are separate install kits, available at www.intermec.com/idl or from www.intermec.com/support/downloads. 9 For more information on configuring your Intermec Computer, please see the Intermec Computer Command Reference Manual located at http://epsfiles.intermec.com/eps_files/eps_man/073529.zip. Use this manual in combination with your Intermec computer user s manual to configure your Intermec Computer. 6

Copyright 2008 Intermec Technologies Corporation. All rights reserved. Intermec is a registered trademark of Intermec Technologies Corporation. All other trademarks are the property of their respective owners. Printed in the U.S.A. 00/08 In a continuing effort to improve our products, Intermec Technologies Corporation reserves the right to change specifications and features without prior notice.