MIAC Proposal Document for HVAC Equipment Design, Installation and Maintenance Services for Oil and Gas Facilities



Similar documents
RPV - RP - RA air handling units

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Element D Services Heating, Ventilating, and Air Conditioning

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

SECTION HEAT PUMPS

ECOCIAT. Domestic hot water heat recovery unit

National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook

Nominal Life Expectancy for Building Components

DESIGN STANDARDS SECTION

SECTION MORTUARY REFRIGERATORS

Maintenance for Energy Efficiency

HVAC Processes. Lecture 7

The prevailing force in the field. AIR CONDITIONING SOLUTIONS FOR THE PULP AND PAPER INDUSTRY

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries

HVAC Systems: Overview

Whitepaper Modular Integration of Process Equipment Packages for Oil and Gas Facilities

Engineered Solutions

Federal Wage System Job Grading Standards for Air Conditioning Equipment Operating, Table of Contents

Are these noise cancelling devices needed to make your chiller quiet??

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

Drives and motors. A guide to using variable-speed drives and motors in retail environments

SYLLABUS For BASIC TRADE COURSE (360 Hours) On REFRIGERATION AND AIR CONDITIONING

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

Building Services Engineering Technician

Why Daikin? 2015 Houston, Texas USA

Guidelines for energy efficient heating, ventilation and air conditioning (HVAC) systems

Knowledge for optimal efficiency

Glossary of Heating, Ventilation and Air Conditioning Terms

, User s Manual

PLUG and PLAY VRV Connection

Dry-type transformers. Dry-type transformers from ABB The ideal solution for the oil and gas industry

HVAC For Schools How to purchase an HVAC system that meets your school s unique requirements and stays within your budget

MAC-120HE-01 Air-Cooled Chiller

SWIMMING POOL AIR-HANDLING UNITS KU-DB Series

Medical Air Systems: Scroll

COMMISSIONING OF HVAC SYSTEMS

BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION

Evaluate, Clean, and Tune Guidance

1.2 Refrigerant Equipment. General

heat treatment equipment & accessories

NSN

Mechanical Rooftop Custom Capabilities

Lesson 36 Selection Of Air Conditioning Systems

MODEL IX -WAC/HP AIR CONDITIONERS & HEAT PUMPS FOR HIGHLY CORROSIVE & HAZARDOUS AREAS

marine refrigeration and air conditioning

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

HVAC and pressurization. IECEx and ATEX

Fig. 2 Option 1 Integrated Design using Physical Separation. Fig. 1 Standard Modular Process Skid Design Concept

DIABLO VALLEY COLLEGE CATALOG

Offshore Substation. HVAC System. ETS-09 Rev. 2. technical standards. Dok Sag 09/1437

III. Roof Mount AC Mobile Climate Control 19 MCC Reference Manual 2014

UR...3 URX CF...7 URHE CF Heat recovery unit. Heat recovery unit with refrigerant circuit( cfm)

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT

CEILING CASSETTE FAN COIL UNIT

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS

Cooking at the Speed of light!

Statement of Work. 3.0 Details of Service Pre Start-up Cooling Start-up Service. Installation Service. Table of Contents. 1.0 Executive Summary

Whitepaper. Modular Substation Cable Termination Design. Author: Allan Bozek P.Eng, MBA, EngWorks Inc, Calgary, Canada

... Offshore solutions. Custom-build and turn-key

SASO XXXX:2016. (Including the modifications approved in Saudi Council Board No. XXX/2016) LARGE CAPACITY AIR CONDITIONERS

Surface Technology. Centrifugal Fan GMD

Addendum to Florida Academy Catalog for: HVAC Fundamentals HVAC Advanced Fundamentals

Refrigeration & Air-conditioning Technician

Consortiwm Awdurdodau Lleol Cymru Consortium Local Authorities Wales

Basics of HVAC Cleaning

Local Dealer:

Design Guide. Retrofitting Options For HVAC Systems In Live Performance Venues

Air Conditioning Equipment

Refrigeration & Air Conditioning

Circuit breaker panel. Power supply for condensing unit. Power supply for furnace. Air handler (Furnace)

GENERAL INFORMATION FOR REPAIR AND MAINTENANCE OF CENTRAL AIR CONDITIONING PLANT ( Direct & Chiller ).

ARMSTRONG AIR HEAT PUMPS

products 22 º C Ventilation Air Conditioning Refrigeration Energy & Cost Saving Products Inside PROVIDED BY HEINEN & HOPMAN

HEATING, VENTILATION & AIR CONDITIONING

Table Z. Troubleshooting Chart for Air Conditioners. Cause

EXAMPLE OF A DATA CENTRE BUILD

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

SPECIFICATION TECHNICAL AIR-CONDITIONING UNITS SINGLE AND SPLIT (DUCTED) (AIR COOLED PACKAGED UNIT)


Center for Energy Education Laboratory

marine/bespoke split applications

HEATER, AIR CONDITIONING AND VENTILATION

Preventive Maintenance. State Energy Assessment Workshop By: DTE Energy Partnership & Services

DUFFERIN-PEEL CATHOLIC DISTRICT SCHOOL BOARD

P. A. Hilton Ltd REFRIGERATION & AIR CONDITIONING VAPOUR COMPRESSION HEAT PUMPS VENTILATION VOCATIONAL

Johnson Air-Rotation Systems

Ammonia Detection System Codes and Design Specifications

COMMERCIAL HVAC CHILLER EQUIPMENT. Air-Cooled Chillers

HP switch LP switch Discharge thermo Comp. Surface thermo

IV. Rear Mount System

Classification and Qualification STANDARDS

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

REFRIGERATION & AIR-CONDITIONING UNIT IIT KHARAGPUR

Facilities Maintenance Standards rev

VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water

Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks

Transcription:

MIAC Proposal Document for HVAC Equipment Design, Installation and Maintenance Services for Oil and Gas Facilities Prepared By: MIAC Services Co., Ltd. Head Office Sukhumvit-Pattaya Soi 31 104/6 Moo 6 Naklua Banglamung Chonburi 20150 Thailand Tel: + 66 (0) 38727891 Fax: + 66 (0) 38727893 sales@miac-hvac.com www.miac-hvac.com 1

Table of content 1. INTRODUCTION... 4 1.0 Introduction... 5 2. COMPANY PROFILE... 6 2.0 Company Profile... 7 3. DESIGN AND CONTACTING... 8 5. SERVICES & MAINTENANCE CAPABILITIES... 9 4.1 Services & Maintenance Capabilities... 11 5. PRODUCT... 12 5.1 Products... 13 HVAC Equipment... 13 Mariner Air Handling Units... 14 Fans... 14 Motors... 14 Cooling Coils... 14 Heating Coils... 14 Filtration... 15 Dampers... 15 Controls and Instrumentation... 15 Wiring and Cables... 15 Configuration... 15 Casings... 15 Condensers... 16 2

Compressors... 16 Condenser Fans... 16 6. MARINE & OFFSHORE TRACK RECORD... 18 Marine & Offshore Track Record... 19 7. MARINE AND OFFSHORE PERSONNEL... 38 7.0 Marine and Offshore Personnel... 39 8. KEY PERSONNEL... 40 9. Gallery...44 3

1. INTRODUCTION 4

1.0 Introduction MIAC Services Co., Ltd is a specialist Heating Ventilating and Air Conditioning (HVAC) company operating exclusively in the Marine and Offshore Industries. Located in Chonburi Thailand between the resort city of Pattaya and 10km from the major shipping terminal in Leam Chabang and occupying 3000 m/2 of HVAC manufacturing space and 500 m/2 of office and engineering space MIAC Marine & Offshore has an excellent platform on which to serve the SEA region and other locations in the world. This proposal has been prepared as a pre-qualification document for the Supply Installation, Commissioning and Aftermarket Services of Heating, Ventilating, Air Conditioning and Refrigeration Equipment & Systems for Marine & Offshore fixed and floating structures specific to the Offshore industries. MIAC Marine & Offshore has an established Contracts Department performing both new build and equipment replacement projects. Our team of professionals consisting of both Expatriate and Thai National Engineers manage Marine and Offshore projects from design through to final commissioning and hand over. MIAC Marine & Offshore has dedicated teams of highly experienced Service Technicians who respond to emergency call outs overhaul & repairs to HVAC and Refrigeration systems in Onshore Industrial, Marine and Offshore facilities. Lifetime Support contracts covering all HVAC and Refrigeration equipment are provided by MIAC Services ranging from routine Planned Preventative Maintenance to Fully Comprehensive parts and labor packages. 5

2. COMPANY PROFILE 6

2.0 Company Profile MIAC Marine & Offshore recognized the need for a quality specialist Heating, Ventilating, Air Conditioning and Refrigeration (HVAC&R) company to serve the needs of the industries very demanding clients operating in South East Asia and internationally. MIAC Marine & Offshore has established a team of specialists to provide solutions to HVAC & Refrigeration in the Offshore, Marine and Offshore Industries. Since 2002, MIAC has been carefully selecting its team of both Thai National and Expatriate personnel who are qualified and experienced in our industry and are able to work with and provide solutions for major international companies. With more than 12 years of HVAC experience exclusively in the Marine and Offshore sector can provide the best HVAC solutions internationally. 7

3. DESIGN AND CONTACTING 8

3.1 Design & Contracting Capabilities MIAC Marine & Offshore designs, supplies, installs and commissions complete HVAC & Refrigeration systems to the Marine and Offshore Oil and Gas Industry. Equipment and systems are designed and manufactured to meet the specific requirements of the customer. Typical examples of Offshore and Marine HVAC & Refrigeration packages are as follows: Hazardous area Air-Conditioning & Refrigeration Systems Unclassified Area Air-Conditioning & Refrigeration Systems Ventilation, Exhaust & Room Pressurization Systems Chillers & Chilled Waters Systems for Corrosive Atmospheres Air & Water Cooled Condensers and Heat Exchangers for Corrosive Atmospheres PLC Control Systems for interfacing HVAC with Facility Control Systems Air Conditioning & Refrigeration Compressors Provisions Stores 9

4. SERVICES & MAINTENANCE CAPABILITIES 10

4.1 Services & Maintenance Capabilities Effective HVAC & Refrigeration equipment repair & maintenance provides a level of assurance in plant and equipment integrity. MIAC Services provides a comprehensive system upgrade, repair & maintenance service covering the complete range of HVAC & Refrigeration products. This service includes the review of existing maintenance routines and performance standards for industrial, and process cooling equipment. For Offshore, Fixed Platforms, Mobile Drilling Rigs & FPSO s. MIAC Marine & Offshore has an Offshore Crew to enable HVAC repairs and maintenance to be performed with confidence. More specialist equipment can be maintained though MIAC Campaign Maintenance Strategy. Heat Exchanger Re-tubing Eddy Current Tube Analysis Compressor Overhauls Motor Repairs & Rewinds Fan Balancing Electrical Repairs Pump Repairs Refrigerant Reclaim Duct Cleaning 11

5. PRODUCT 12

5.1 Products MIAC Marine & Offshore has developed a range of HVAC products specifically for the Marine and Offshore Oil and Gas Industry; this is the MIAC Mariner product range covering Packaged and Split equipment up to a capacity of 350kW. HVAC Equipment MIAC Marine & Offshore has a significant range of standard HVAC Products specifically designed to meet the requirements of the Marine & Offshore Industry. Most HVAC equipment used in Marine and Offshore applications is derived from existing Industrial Products and modified to meet project specifications. The MIAC MARINER HVAC products have been designed specifically to meet the stringent requirements for Marine and Offshore applications. To develop Mariner Equipment, it was necessary go back to the basics to design from the bottom up and establish an engineered design which ensures long equipment life cycle and reliability and reduced maintenance requirements. The key to our product design is flexibility: Flexibility in Design Flexibility in Capacity Flexibility in Dimensions Flexibility in Materials Flexibility in Area Classification MIAC manufactures HVAC equipment for the Marine & Offshore and Energy Industry. Air Handling Units Air Cooled Condensing Units Packaged Skid Air Cooled Chillers Water Chillers HVAC Control Package Utilizing our standard construction method each unit is specifically designed to comply with project requirements. A complete range of specialist materials are used to comply with the stringent requirements of our industry and to ensure the required design life. 13

Mariner Air Handling Units Constructed from Stainless Steel and double skin as standard with mineral wool insulation, fully welded penta-post construction for rigidity and long life, the double skin construction also helps prevent noise break out. MIAC Mariner design incorporates features to prevent thermal bridging and prevents condensation forming on the outer surface. All internal components are removable via the service access doors or removable casing panels. Fans A complete selection of fans is available to meet specifications generally pressed steel forward curve or welded steel backward inclined and manufactured mild steel or stainless steel. Non- sparking components such as brass inlet cones and drive guards are used to comply with hazardous area requirements. Fan systems are engineered to maintain room or building pressurization without the need for additional pressurization systems. Motors Drive motors are generally Totally Enclosed Fan Cooled and available with Voltage and Frequencies to meet client requirements. Where required we use motor manufactures to comply with client preferred vendors. All Safe Area motors are also provided complying with Zone 1 or Zone 2 Area Certification. Cooling Coils Cooling coils for both Chilled Water and Direct Expansion coils are manufactured from various materials to comply with client requirements including Copper fins with epoxy coating and Electro Tinned Copper fins. The Coil frame is Stainless Steel. The copper tubes are fitted with the copper fins and then the tubes are expanded to ensure reliable thermal transfer through the fins under all working conditions. Heating Coils Heating Coils are available for hot water or steam in the same materials as cooling coils, while electric heating coils with stainless steel elements are available with Zone 1 or Zone 2 Area Certification. 14

Filtration High efficiency bag and panel filters are provided and installed in a stainless steel frame with rotating securing devices to allow easy replacement with minimum effort. Other special filters such as HEPA and coalescing are available as specifications require. Dampers A wide range of dampers are available to meet specific requirements, these include Fire, Volume Control, Mixing, Shut Off and Back Draft. Damper control is achieved by manual locking quadrants, electric or pneumatic actuators with hazardous area classification equipment. The dampers are manufactured from stainless steel with high quality maintenance free bearings on moving parts. Controls and Instrumentation Pressure indicators, sensors and switches are provided for data transmission on filter condition, fan performance, damper positions and other critical components. These are factory installed and wired to a control junction box for simple on-site connections. The instruments and junction boxes comply with the area electrical classification. Wiring and Cables All electric motors, space heaters and other power-driven devices are factory wired to a junction box installed outside the casing for ease of site connection. Cables are halogen-free with glands and junction boxes complying with area classification. Configuration Air handling units can be configured as a Single Skid unit, Duty Standby configuration Double Stacked or Side By Side. Condensing Units can also be fitted to the same skid making a selfcontained Packaged HVAC Skid whereby these can then be factory tested and commissioned cutting down the work scope in the shipyard or offshore. In addition Air Handling Units can be built in sections for assembly in a final location where access space is restricted. Casings MIAC Marina AHU & Condensing Units have a standard design and construction method, as with all MIAC Marina HVAC products, flexibility is the main consideration. 15

Condensers Accessibility for maintenance and condenser airflow direction are two of the important factors always considered. Compressors are positioned inside the condensing unit envelope with maintenance access through a door or removable panel allows monitoring of oil sight glasses and removal of compressor components for servicing. Other items in the refrigerant circuit are positioned so that routine maintenance can be carried out easily. Condenser air flow direction is also flexible with top, side or end discharge depending on location of surrounding equipment. Compressors Compressors are selected for flexibility using either Semi Hermetic Reciprocating or Screw type. They are also available with open drive motors. The compressors and electrical components are also available to comply with hazardous area classifications. Compressors are mounted on isolators to prevent vibration being transmitted to buildings or other structures. Compressor safety controls are selected to meet hazardous area classification where required. Condenser Fans Condenser Fans are directly mounted to the motors to reduce vibration and maintenance requirements. Various fan materials are available including UV resistant poly carbon and marine grade aluminium. Anti-spark tracks are also available for positioning inside housings. Condenser Coils Condensing coils are manufactured from various materials to comply with client requirements including Copper fins with epoxy coating and Electro-tinned copper fins. The MIAC product range includes Air Cooled Condensing Units (5 to 375 kw) Air Cooled Water Chillers (20 to 375 kw) 16

Air Handling Units System Control & Communication Packages Refrigeration Skid Packages Refrigerant Leak Monitoring Systems Duct Heater Units Stainless Steel Ductwork The Spare Parts Supplies Division of MIAC Marine & Offshore provides Air-Conditioning and Refrigeration Spare Parts to Hazardous Area, Offshore Platforms & FSPO s and Marine Industries. MIAC has a long established relationship with a variety of manufactures enabling us to offer a wide range of new and direct replacement equipment competitively. The range of items includes: Air Handling Units, Fan Coil Units and Components Air Conditioning Units, Spare Parts, Controls Air Filters, Belts, Fans & Motors, Industrial & Hazardous Area Rated Air Filtration Units and Spare Parts Compressor & Spares, Bock, Bitzer, Carrier, Trane, York, J&E Hall, Copeland Maneurop etc. Ductwork & Components inc VCD s Fire Dampers, Heater batteries Silencers & Grills Evaporators & Condensers both Air & Sea Water Cooled Galley / Kitchen Refrigeration & Spares Pumps, Seals, Bearings & Pulleys Refrigerant Gasses including drop in replacements for CFC/HCFC s Refrigerant Oils for all types of applications Refrigeration parts, expansion valves, pressure & temperature controls Specialist Electrical Equipment & Control Systems Water Chillers for Air-Conditioning & Industrial Applications Specifications include: Hazardous Area Semi Hermetic Compressors including crank case heaters Hazardous Area Electric Motors Hazardous Area Unit Controls and Sensors Anti-Spark Fans Corrosion resistant materials and SS316L Options Marine Grade Water to Water Heat Exchangers Copper fin Evaporator and Condenser Coils with Electro Tinned and other Special Coatings. 17

6. MARINE & OFFSHORE TRACK RECORD 18

Marine & Offshore Track Record Year 2002 ChevronTexaco Benchamas Expansion Project New HVAC equipment had been installed on BLQ and BPP platforms by another company but was not commissioned. Working under a sub-contract to Premier Environmental, MIAC Engineering was employed to take over and successfully complete the HVAC project. Scope of work BLQ Commission 55kW capacity HVAC system serving the Instrument & Electrical Workshop, Mechanical Workshop and Maintenance Stores. Commission two (one run, one standby) 35 kw capacity HVAC systems servicing the Central Control Room. BPP Commission two (one run one standby) 55 kw capacity HVAC systems serving the Motor Control Center and Laboratory. Year 2003 Chevron Benchamas HVAC Modifications & Upgrades As a result of earlier HVAC commissioning, subsequent reports and recommendations, modifications and upgrades were necessary in order that the systems would perform correctly and reliably. Working under a sub-contract to Premier Environmental, MIAC Marine & Offshore was employed to perform system modifications and upgrades. Scope of Work BLQ Equipment 55kW capacity HVAC system serving the Instrument & Electrical Workshop, Mechanical Workshop and Maintenance Stores. 19

Repair refrigerant leaks and modify system to prevent further leaks. Modified electrical control systems in order to maintain correct operating temperatures in individual air conditioned spaces. Two (one run one standby) 35 kw capacity HVAC systems servicing the Central Control Room. Installed Current Inverter Drives to the supply air fan motors in order to reduce excessive static pressure and noise in control room. Modified control system in order to control room humidity. Modified control system to provide automatic change-over function should operating system go into fault status. Installed a standalone packaged unit to cool UPS and Communication Equipment room. BPP Equipment Two (one run one standby) 55 kw capacity HVAC systems serving the Motor Control Center and Laboratory. Installed Current Inverter Drives to the supply air fan motors in order to control excessive static pressure fume cupboard extract in Laboratory. Installed air lock door system on entrance to Laboratory. Modified control system to provide automatic change over function should operating system go into fault status. Year 2003 / 2004 Chevron MFP Stage 2 Eight well head platforms which included control room HVAC systems were to be constructed by Thai Nippon Steel at their Samut Prakarn yard. Early in the project Chevron identified a deficiency with their Singapore based HVAC system vendor. MIAC Engineering was employed to carry out a survey of the first platform prior to its sail away to the Tantawan field. The survey and subsequent report to Chevron identified a number of deficiencies in the design, selection and construction of the MFP 2 HVAC systems. 20

As a result of a meeting between Singapore contractor, Chevron and MIAC Engineering, a contract was placed for QA/QC to be undertaken by MIAC Engineering. Scope of Work Work with HVAC vendor at their Singapore factory to modify HVAC system design, and construction method. Visit manufacture of Fire and Barometric dampers in Malaysia to discuss and overcome various manufacturing issues. Visit Singapore vendor and perform Factory Acceptance Testing of prior to shipping of each HVAC system. Supervise commissioning and functionality of HVAC for each platform prior to sail away. Supervise offshore modifications carried out by Singapore Vender to HVAC systems. 2004/2005 CUEL PLOCPP2 Processing and Utility Platform Fabricated in Leam Chabang, Chonburi Scope of Work Fabrication and installation of air distribution system including fire dampers, volume control dampers, stainless steel external ductwork and galvanized internal ductwork. Due to complexity of Control Room part of the fabrication was carried out in Leam Chabang yard then completion of ductwork carried out offshore. Install interconnecting refrigeration pipework comprising of four circuits between compressor banks, air cooled condenser and two air handling units. Pressure testing, dehydration & evacuation, charging with refrigerant and refrigeration system commissioning. 21

2004/2005 Chevron BLQ Galley Freezer Called to platform to provide specialist assistance, after surveying the system most of the equipment was beyond its useful life, temporary repairs were made to keep the system operational, this was followed with a proposal to replace the equipment. The proposal was subsequently accepted, equipment including condensing units, indoor blowers, pipework and cabling was replaced. As part of this exercise both cold rooms were upgraded to achieve temperature of 20degC. 2006 Global Santafe Compact Driller Survey to Compact Driller HVAC systems covering short term, medium term and long term issues. Complete engineering report covering HVAC systems with supporting engineering and HSE documentation. Replacement and upgrade of HVAC systems in accommodation section, replaced condensing units and replaced refrigerant to non CFC 2006 Specialist Services (Dubai) Chevron Additional Living Quarters (Benchamas ALQ) Complete HVAC for living quarters module for 44 personnel. 22

Turnkey package including Detailed Design, Manufacturing, Installation and Commissioning. Design and production of software for Alan Bradley HVAC PLC Hazardous area Class 1 Division 2 rated equipment with complete Alan Bradley PCL driven control system interfacing platform master control. Fabrication and installation of air distribution system including fire dampers, volume control dampers, stainless steel external ductwork and galvanized internal ductwork. Install interconnecting refrigeration pipework comprising of four circuits between compressor banks, air cooled condenser and two air handling units. Pressure testing, dehydration & evacuation, charging with refrigerant and refrigeration system commissioning. Manufacture of Duty and Standby Custom Built Air Handling Units and Condensing Units. 2007 CUEL Thailand CTOC Carigali Hess Compressor Module Equipment Shelter (CKR3) Complete HVAC system for Equipment Shelter. Turnkey package including Detailed Design, Manufacturing, Installation and Commissioning. Complete 100% Duty and 100% standby configuration. Air Cooled Condensing Units custom built from MIAC Mariner product range, with Stainless Steel 316L with ATEX Compressor and Condenser Fan Motor with Anti Spark Features on Fan Assembly. MIAC Mariner Air Handling Unit also fabricated from SS316L with 50mm double skin insulated panels, ATEX motors and fully welded heavy duty spark resistant supply air fan. SS316L electrically operated shut off dampers on supply and return air with ATEX motors fully isolate the standby sections. Design and manufacture internal and external ductwork from Stainless Steel 316L with double skin and internal perforated SS316L plate 23

The HVAC Control and Motor Control Center manufactured in house by MIAC includes Allen Bradley PLC with HMI panel, program developed by MIAC, integrated fire and gas control communicating with Fire Damper (also provided by MIAC) and facility system Hazardous area Class 1 Division 2 rated equipment with complete Alan Bradley PCL driven control system interfacing platform master control. Fabrication and installation of air distribution system including fire dampers, volume control dampers, stainless steel external ductwork and galvanized internal ductwork. Fabrication executed in Leam Chabang Thailand Install interconnecting refrigeration pipework comprising of four circuits between compressor bank, air cooled condenser and two air handling units. Pressure testing, dehydration & evacuation, charging with refrigerant and refrigeration system commissioning. Fabrication of Duty and Standby Air Handling Units and Condensing Units in SS 316L 24

2007 Direct Engineering Services Marine & Offshore KUPE Well Head Platform Manufacture and supply Stainless Steel 316L ductwork and associated equipment for ventilation and pressurization system. Design and manufacture Duct Heaters. 2007 Direct Engineering Services Marine & Offshore Puteri Project Carigalli Malaysia Design and manufacture air conditioning split systems to marine & offshore specifications and associated control panels with Siemens PLC. Commissioned equipment in Malaysian shipyard before load out. 25

2007 Direct Engineering Services Marine & Offshore B 295 Keppel Fels manufacture HVAC Control Panels complying with the design of DES 2007 Global SantaFe Vietnam Upgrade and change out of HVAC accommodation, switch & control room and provisions store equipment on Galveston Key jack up driller changed out all other HVAC refrigerants to HFC. This project was executed while the rig was operational offshore therefore a high level of planning and logistics was essential. 2007 Direct Engineering Services Marine & Offshore AFAM / Okoloma Shell Nigeria Manufacture HVAC Control Panels Complying to the design of DES 2007 Direct Engineering Services Marine & Offshore B 273 / 4 / 5 / 6 Keppel Fels manufacture HVAC Control Panels complying to the design of DES 26

2008 FPSO Vincent Mearsk, Keppel Yard Singapore Commissioning complete HVAC system in Accommodation Section and M85 Generator Control Room. Responsible for pre-commissioning electrical services, start up and commissioning of chilled water system, pumps, chillers and air handling units. Commissioning and testing of fire dampers and air balance. 2008 Global SantaFa Compact Driller, Gulf of Thailand Complete replacement provisions stores refrigeration equipment. Manufacture and install new condensing units and electrical control system, install new evaporator units and interconnecting pipework and cabling. 27

2008 Nexus FPSO Samsung Heavy Industries, Direct Engineering Services. Design and manufacture complete provisions store refrigeration system. Including water cooled refrigeration condensing unit skid, electrical control system and evaporator units. System includes Packaged Skid with open drive compressors, water cooled condensers and integral control and MCC system. 2009 D30 MOPU Integrated Technologies Sdn. Bhd Global Processing Systems Design, supply, install and commission HVAC System for CCR Module. Work performed in MMHE Ship Yard in Johor Malaysia. 2009 Dana MOPU Integrated Technologies Sdn. Bhd Global Processing Systems Design, manufacture, supply and install a forced ventilation system for all below deck areas and HVAC system for UPS and Switch Gear rooms. Installation performed in MMHE Ship Yard in Johor, Malaysia. Galvanized Steel ductwork with SS316L Fire Dampers. Air intake goose necks with integral supply air fans and watertight doors all designed and manufactured by MIAC to ABS standards. 28

2009 Chim Sao Vietnam TX Engineering PTSC Premier Oil Design, Manufacture, Supply and Commission HVAC system for Chim Sao platform. Engineering and manufacture carried out at MIAC-ARV workshop in Thailand, equipment delivered to Vung Tao Vietnam for installation and commissioning. complete 100% Duty and 100% standby configuration. Air Cooled Condensing Units custom built from MIAC Mariner product range, with Stainless Steel 316L with scroll compressors ATEX Condenser Fan Motor with Anti Spark Features on Fan Assembly. MIAC Mariner Air Handling Unit also fabricated from SS316L with 50mm double skin insulated panels, ATEX motors and fully welded heavy duty spark resistant supply air fan. SS316L electrically operated shut off dampers on supply and return air with ATEX motors fully isolate the standby sections. Design and manufacture internal and external ductwork from Stainless Steel 316L with double skin and internal perforated SS316L plate. The HVAC Control and Motor Control Center manufactured in house by MIAC includes Allen Bradley PLC with HMI panel, program developed by MIAC, integrated fire and gas control communicating with Fire Damper (also provided by MIAC) and facility system. 29

2010 Platong Offshore Facility Asian Offshore Services Chevron Thailand Exploration and Production Design, Manufacture, Install and Commission complete HVAC system for existing and extension to Switch and Control Room on Platong CPP located in Gulf Of Thailand complete 100% Duty and 100% standby configuration Packaged Units. Air Cooled Condensing Section custom built from MIAC Mariner product range, with Stainless Steel 316L with ATEX Compressors and Condenser Fan Motors with Anti Spark Features on Fan Assembly. MIAC Mariner Air Handling Section also fabricated from SS316L with 50mm double skin insulated panels, ATEX motors and fully welded heavy duty spark resistant supply air fan. SS316L Electrically operated shut off dampers on supply and return air with pneumatic actuators fully isolate the standby sections. 30

Design and manufacture internal and external ductwork from Stainless Steel 316L with double skin and internal perforated SS316L plate The HVAC Control and Motor Control Center manufactured in house by MIAC includes Allen Bradley PLC with HMI panel, program developed by MIAC, integrated fire and gas control communicating with Fire Damper (also provided by MIAC) and facility system. 2010 Benchamas Offshore Facility Gulf of Thailand Airco Chevron Thailand Exploration and Production Design, Manufacture, Install and Commission complete HVAC system for existing Motor Control Center on Benchamas Facility located in Gulf Of Thailand complete 100% Duty and 100% standby configuration. Air Cooled Condensing Units custom built from MIAC Mariner product range, with Stainless Steel 316L with ATEX Compressor and Condenser Fan Motor with Anti Spark Features on Fan Assembly. MIAC Mariner Air Handling Unit also fabricated from 31

SS316L with 50mm double skin insulated panels, ATEX motors and fully welded heavy duty spark resistant supply air fan. SS316L electrically operated shut off dampers on supply and return air with ATEX motors fully isolate the standby sections. Design and manufacture external ductwork from Stainless Steel 316L with double skin and internal perforated SS316L plate. The HVAC Control and Motor Control Center manufactured in house by MIAC includes Allen Bradley PLC with HMI panel, program developed by MIAC, integrated fire and gas control communicating with Fire Damper (also provided by MIAC) and facility system. 2011 Lewek Emas Chim Sao Vietnam Block 12 FlaktWoods Oil & Gas Singapore Design, Manufacture, Test and Supply three split air conditioning systems serving Control Room and Electrical Room. The Air Cooled Condensing Units custom built from MIAC Mariner product range, with Stainless Steel 316L with ATEX Compressor and Condenser Fan Motor with Anti Spark Features on Fan Assembly, Explosion Proof Integrated Starter Control Panel. Indoor units from Standard Carrier product range. All outdoor equipment rated for use in a Zone 2 Hazardous Area, indoor equipment is suitable for Safe Area environment. 32

2012 Oakwell Engineering Final Client Fugro Installed Tested and Commissioned HVAC System for Survey Vessel Equator in Oakwell Shipyard Sattahip Thailand. Attended sea trials and support to client end of project. Suretank Final Client Schlumberger Design, Manufacture, Install and Test HVAC and Electrical System for workshop shelter For use in Zone 2 application. Oceanmaster Final Client Transocean Design Manufacture and Supply Air Cooles Condensing Units serving workshops, and switchgear rooms on Galveston Key Jack up Driller. 2012 / 2013 Ilk Construction Istanbul Final Client: Dragon Oil Turkmenistan Engineering, Design, Manufacture and Commissioning of complete HVAC System for both Accommodation and Wellhead Platforms to be located in Caspian Sea. All HVAC systems for both platforms comprise of Reverse Cycle Heat Pump systems providing both heating and cooling to Accommodation and Equipment Shelters. All outdoor Reverse Cycle Condensing Air Cooled Units manufactured from SS316L and manufactured to Marine & Offshore standards and controlled by individual PLC s. One HVAC control panel provided for each platform with integral PLC s 33

2012 / 2013 Global Processing Systems Final Client: ABB and SBM Engineering, Detailed Design, Manufacture, Installation and Commissioning of complete HVAC system for ABB Electrical Room for Saikap FPSO project. Duty and Standby Air Cooled Packaged MIAC Marina Air Conditioning Units manufacture in SS316L to Zone 2 requirements. Complete MIAC HVAC system design approval by ABS in Singapore. Installation and commissioning and SAT was performed in Batam Indonesia. 2013 Thai Nippon Steel Final Client: Salamander Energy Engineering, Detailed Design, Manufacture of complete HVAC system for two electrical and control rooms, laboratory and battery room. Project includes two Multi System MIAC Marina Air Cooled Condensing Unit and two HVAC Starter / Control Panels with Allan Bradley PLC s. Installation and TNS Yard Thailand. 34

Thai Nippon Steel Final Client: Salamander Energy Engineering, detailed design and procurement of ventilation system for crude oil fired generator room, zone 2 ventilation system includes supply and extract air fans, fire dampers and hazardous area ventilation control panel with Allan Bradley PLC. 35

2014 Direct Client: Chevron Exploration and Production Thailand North Pailin LQ Radio Room Design, Manufacture, Test and Install additional HVAC equipment in LQ Radio Room. 36

2014 Ongoing Projects Suretank Final Client: Atwood Drilling Engineering and design of Air Conditioning System, Electrical and Architectural System for Offshore Gymnasium to ABS approvals. Ilk Construction Final Client: Dragon Oil Living Quarters and WPP, Caspian Sea Supervise installation of HVAC and Control Equipment, Testing and Commissioning in Turkmenistan Thai Nippon Steel Final Client: Mubadala Petrolium Nong Yao WPP-A & WHP-B Design, Detailed Engineering, Manufacture, Testing, Installation and Commissioning of complete HVAC System serving Instrument & Control Rooms, Switchgear Rooms, Battery Rooms and Kitchen on two platforms for Gulf of Thailand. 37

7. MARINE AND OFFSHORE PERSONNEL 38

7.0 Marine and Offshore Personnel MIAC Services employs both Local and Expatriate personnel to perform its marine and offshore operations. Employee recruitment carried out at senior management level, applicants are from a variety of sources, previous working relationships, newspaper advertising, internet and recruitment agencies. Both Local and Foreign National applicants are rigorously checked prior to being employed by the company. Our checking and verification procedures ensures that prospective employees are suitably qualified, experienced and have the necessary qualities to work unsupervised in the offshore environments. All employees are provided with social security benefits and private health and accident insurance which provide cover for health care, in addition employees who work offshore or travel outside our home base are provided with special travel health care. 39

8. KEY PERSONNEL 40

Key Personnel The following are the key personnel who provide technical expertise, experience and direction to MIAC Services. Name Photos Position Nationality Duties Jeffrey Hulse Technical and Marketing Director British System Design, Manufacture and Offshore Operations Jintana Sukkhang Financial Controller Thai Financial and Commercial control of the organization Ngo Huu Huy Project Coordinator - Proposal Vietnamese Project management, scheduling, proposal Vo Thanh Hon HVAC Design Lead Engineer Vietnamese HVAC & Refrigeration Design, Systems & Manufacturing. Control of Drawing Office 41

Adirek Klahan Lead Electrical& Instrumentation Thai Control systems design, programming & commissioning Kingkan Lintongkum Procurement Officer Thai Materials Purchasing and Logistics Sing Turee Draftsman Thai CAD and 3D Modeling System Operator Sutthi Sonsupab QA/QC Manager Thai QA/QC Assuarance Phonglerrt Kerdtem QHSE and Documentation Engineer Thai Quality Health & Safety and Environmental Thannasrn Bunpung Accounts Thai Payments and collections 42

Aree Klomkhum HR and Admin Thai Human Resource / Travel and general administration 43

9. GALLERY 44

9.0 Gallery Installation & Commissioning PLOCPP2 CUEL Thailand 38kW Double Stacked AHU Chim Sao PTSC Vietnam Stainless Steel Ductwork KUPE TNS Thailand 45

205kW Packaged Unit Chevron Thailand Platong CPP Electrical Control Room 38 kw Air Cooled Condensing Units Chim Sao PTSC Vietnam 78 kw Heat Pump Condensing Unit Zhandnov B Accommodation Platform Dragon Oil Turkmenistan 46

30kW Horizontal ACCU Zone 2 Chevron Benchamas Thailand 60 kw Packaged Air Conditioning Units for ABB Saikap FPSO Electrical Shelter Ventilation Goose Necks MOPU Dana MISC / Petronas 47

12 kw Air Cooled Condensing Unit Lerwik EMAS FPSO Chim Sao Vietnam OEM For Flaktwoods 48