THINKTEL COMMUNICATIONS DIGIUM G100/G200 PRI OVER IP SIP TRUNKING



Similar documents
THINKTEL COMMUNICATIONS CUDATEL PHONE SYSTEM 270. High Availability and SIP-TRUNK Configuration

Digium Switchvox AA65 PBX Configuration

THINKTEL COMMUNICATIONS TALKSWITCH VS TALKSWITCH VS THINKTEL SIP TRUNK & DID

Quick Installation Guide

VoIPon Tel: +44 (0) Fax: +44 (0)

THINKTEL COMMUNICATIONS 3CX PHONE SYSTEM V.11. 3CX Phone System THINKTEL SIP TRUNK from scratch

Configuration guide for Switchvox and Cbeyond.

Allo PRI Gateway and Elastix Server

3CX PBX v12.5. SIP Trunking using the Optimum Business Sip Trunk Adaptor and the 3CX PBX v12.5

Optimum Business SIP Trunk Set-up Guide

This document is an application note for connecting the GS8 modular gateway with Zed-3 SE family IP PBX.

Knowledgebase Solution

SIP Trunk Configuration Guide. using

Kerio Operator. Administrator s Guide. Kerio Technologies

SIP Trunking using the EdgeMarc Network Services Gateway and the Mitel 3300 ICP IP-PBX

CyberData VoIP V2 Speaker with VoIP Clock Kit Configuration Guide for OmniPCX Enterprise

6.40A AudioCodes Mediant 800 MSBG

Configuring the Avaya B179 SIP Conference Phone with Avaya Aura Communication Manager and Avaya Aura Session Manager Issue 1.0

How to Config MTG1000B With T1 and Elastix

Wave 500 IP PBX v4.5. SIP Trunking using the Optimum Business Sip Trunk Adaptor and the Wave 500 IP PBX v4.5

Configuring a Mediatrix 500 / 600 Enterprise SIP Trunk SBC June 28, 2011

FortiVoice. Version 7.00 VoIP Configuration Guide

Integrating Citrix EasyCall Gateway with SwyxWare

TALKSWITCH VOIP NETWORK TROUBLESHOOTING GUIDE

EarthLink Business SIP Trunking. Switchvox SMB 5.5 & Adtran SIP Proxy Implementation Guide

SIP Trunking using Optimum Business SIP Trunk Adaptor and the Cisco Call Manager Express Version 8.5

Quick Installation Guide

Elastix Server VoIP Intercom Setup Guide

How to Configure the Toshiba Strata CIX for use with Integra Telecom SIP Solutions

F-SECURE MESSAGING SECURITY GATEWAY

TELEPHONE MAN OF AMERICA. Earning Your Business Every Step of the Way!

Configuration Guide for connecting the Eircom Advantage 4800/1500/1200 PBXs to the Eircom SIP Voice platform.

Digium IP-PBX. SIP Trunking using the Optimum Business SIP Trunk Adaptor and the Digium IP-PBX

SIP Trunking using Optimum Business SIP Trunk Adaptor and the Allworx 6x IP PBX

nexvortex Setup Guide

Quick Start Guide v1.0

VoIP Network Configuration Guide

Mediatrix 4404 Step by Step Configuration Guide June 22, 2011

Enabling NAT and Routing in DGW v2.0 June 6, 2012

How To Deploy Sangoma Sbc Vm At Amazon Cloud Service (Awes) On A Vpc (Virtual Private Cloud) On An Ec2 Instance (Virtual Cloud)

Setup Reference Guide for KX-NS1000 to SBC SIP Trunking

Configuring Sonus SBC 1000/2000. with. Rogers Business Solution (RBS) SIP Trunking Service. Application Note

Cisco Unified Communications Manager SIP Trunk Configuration Guide

VOIP NETWORK CONFIGURATION GUIDE RELEASE 6.10

Configuring PPP And SIP

How to Configure the Cisco UC500 for use with Integra Telecom SIP Solutions

Fonality. Optimum Business Trunking and the Fonality Trixbox Pro IP PBX Standard Edition V p13 Configuration Guide

FLX VoIP Registering with Avaya IP Office 500

SIP Domain/Proxy, Ring Detect Extension or/and Page Audio Extension, (The 8180 needs its own phone extension) Authentication ID, Password,

Setup Reference guide

Configuring a customer owned router to function as a switch with Ultra TV

Savvius Insight Initial Configuration

Kerio Operator. Getting Started Guide

Setting Up an AudioCodes MP-114

Installation of the On Site Server (OSS)

Mediatrix Gateway 440x Series Quick Configuration Guide

Setup Reference Guide for KX-TDE/NCP to SBC SIP Trunking

Application Note Configuring the Synapse SB67070 SIP Gateway for Broadvox GO! SIP Trunking

Using VDOMs to host two FortiOS instances on a single FortiGate unit

How to Configure the NEC SV8100 for use with Integra Telecom SIP Solutions

SIP Trunking with Elastix. Configuration Guide for Matrix SETU VTEP

SIP Trunking using the Optimum Business SIP Trunk Adaptor and the FortiVoice IP-PBX

F-Secure Messaging Security Gateway. Deployment Guide

How to Configure the Avaya IP Office 6.1 for use with Integra Telecom SIP Solutions

VoIP CONFIGURATION GUIDE FOR MULTI-LOCATION NETWORKS

Using the NetVanta 7100 Series

AudioCodes Mediant 1000 Configuration Guide

Cisco Unified Communications Manager SIP Trunk Configuration Guide for the VIP-821, VIP-822 and VIP-824

NetVanta 7100 Exercise Service Provider SIP Trunk

UCM61xx Configuration

Switchvox. Technical Application Notes

How to Configure MTG200 with FreePBX

Firewall VPN Router. Quick Installation Guide M73-APO09-380

FUSION 3CX APP NOTES 11/03/2015

nexvortex Setup Template

DLink-655 Router Configuration Guide for VoIP

APPLICATION NOTE. CC5MPX Digital Camera and IPn3Gb Cellular Modem 10/14. App. Note Code: 3T-Z

Kerio Operator. Administrator s Guide. Kerio Technologies

Avaya IP Office SIP Trunk Configuration Guide

SIP Trunking with Allworx. Configuration Guide for Matrix SETU VoIP Gateways

ZyXEL IP PBX Support Note. ZyXEL IP PBX (X2002) VoIP. Support Notes

Multi-Homing Dual WAN Firewall Router

Application Notes for Configuring Yealink T-22 SIP Phones to interoperate with Avaya IP Office - Issue 1.0

Internet Telephony PBX System

Setup Reference Guide for KX-NS1000 to SBC interconnection

Setup Reference guide for PBX to SBC interconnection

3CX IP PBX with Twilio Elastic SIP Trunking Interconnection Guide

Configuration Notes 283

Yealink Phones User Guide Bicom Systems

Dramatically simplifying voice and data networking HOW-TO GUIDE. Bundle Quick Start Guide

Configuring Avaya 1120E, 1140E, 1220 and 1230 IP Deskphones with Avaya IP Office Release 6.1 Issue 1.0

Visocall IP PBX Connection

Avaya IP Office 8.1 Configuration Guide

SIP Trunking using Optimum Business Sip Trunk Adaptor and the Zultys MX250 IP PBX

Elluminate Live! Access Guide. Page 1 of 7

D-LINK DPH-140S SIP PHONE INSTALLATION GUIDE

Using LifeSize systems with Microsoft Office Communications Server Server Setup

NF5 VOIP Setup Guide (for Generic)

ThinkTel ITSP with Registration Setup Quick Start Guide

Virtual Appliance Setup Guide

Transcription:

THINKTEL COMMUNICATIONS DIGIUM G100/G200 PRI OVER IP SIP TRUNKING

TA B L E O F C O N T E N T S 1.1 NETWORK DIAGRAM... 3 1.2 COLLABORATION OF MONARQUE TELECOM... 3 1.3 CONNECTING TO THE DIGIUM G100... 4 1.4 IP CONFIGURATION... 5 1.5 SIP-TRUNK CONFIGURATION... 5 1.6 CALL SETTINGS... 7 1.7 MEDIA SETTINGS... 8 1.8 GLOBAL SIP SETTINGS... 8 1.9 T1/E1 CONFIGURATION... 10 1.10 CALL ROUTING RULES... 12 1.11 CONNECTION STATUS... 14 1.12 OUTGOING AND INCOMING CALLS... 15 1.13 BACK UP THE CONFIGURATION... 15 1.14 FIREWALL CONFIGURATION... 16 THINKTEL COMMUNICATIONS Reference Edition Page Montreal/IOT/2004 2 2/16

1.1 NETWORK DIAGRAM -For this case we are going to use only one PRI interface on a G100, 23 concurrent calls 1.2 COLLABORATION OF MONARQUE TELECOM All these tests were carried out and implemented in collaboration with MONARQUE TELECOM Elite Digium Switchvox IP-Systems and DIGIUM G100/G200 distributor, a company specializing in business VoIP and hosted IP telephony http://www.monarque.ca THINKTEL COMMUNICATIONS Reference Edition Page Montreal/IOT/2004 2 3/16

1.3 CONNECTING TO THE DIGIUM G100 First the DIGIUM G100 must be connected to the mains with the power cable. It is recommended to connect the DIGIUM G100/G200 Via Statically assigned IP address, Connect one end of an Ethernet cable to the G100 Ethernet port, and the other end to an Ethernet connection on a computer. That computer will need to use the network configuration listed below IP: 192.168.69.2 Netmask: 255.255.255.0 Open a browser window and enter the default IP address for the Gateway using HTTPS https://192.168.69.1 username: admin password: admin It is highly recommended that the admin password be changed using the System Administrators menu on the web GUI THINKTEL COMMUNICATIONS Reference Edition Page Montreal/IOT/2004 2 4/16

1.4 IP CONFIGURATION Click on >> IP Don t enable the parameter Obtain an IP address via DHCP Specify the static IP address for the G100 by entering a valid local IP to System IP Address Enter the Network Mask Enter the Gateway IP Address Enter the DNS IP Address Leave Also Continue Using Default IP Address to YES Note : When you enter the Static IP Address the Gateway will immediately be unresponsive from its old IP address. It may take up to 15 seconds for the new IP address to be assigned and functional. The new IP address of the Gateway (For our case 192.168.1.202) must be entered into the Browser and use the following link https://192.168.1.202 1.5 SIP-TRUNK CONFIGURATION Click on >> SIP Endpoints Click on Create SIP Endpoint On the Tab MAIN set Enable Advanced Options to YES On Name enter ThinkTel On Username enter the pilot number provided by ThinkTel On Password enter the password provided by ThinkTel On Registration choose This gateway registers with the endpoint THINKTEL COMMUNICATIONS Reference Edition Page Montreal/IOT/2004 2 5/16

On Destination Number enter the same number as the pilot number provided by ThinkTel On Hostname or IP Address enter the FDQN or the IP Address of the SIP Proxy server provided by ThinkTel On Use UDP choose YES On Use TCP choose NO On Authentication User same as pilot number On From User same as pilot number On From Domain same as Hostname On Remote Secret same as Password On Port 5060 On Qualify enabled YES On Qualify Frequency 60 Click on Save Endpoint THINKTEL COMMUNICATIONS Reference Edition Page Montreal/IOT/2004 2 6/16

1.6 CALL SETTINGS Click on TAB Call Settings Configure all Parameters as shown below Click on Save Endpoint THINKTEL COMMUNICATIONS Reference Edition Page Montreal/IOT/2004 2 7/16

1.7 MEDIA SETTINGS Click on Tab Media Settings Enable ULAW and G729 Disable ALAW, G722, G726, GSM Click on Save Endpoint 1.8 GLOBAL SIP SETTINGS THINKTEL COMMUNICATIONS Reference Edition Page Montreal/IOT/2004 2 8/16

Click on >> Global SIP Settings Configure all Parameters as shown below THINKTEL COMMUNICATIONS Reference Edition Page Montreal/IOT/2004 2 9/16

1.9 T1/E1 CONFIGURATION Click on >> T1/E1 Click on Tab Port 1 Configure all Parameters as shown below THINKTEL COMMUNICATIONS Reference Edition Page Montreal/IOT/2004 2 10/16

Click on Save T1/E1 Settings THINKTEL COMMUNICATIONS Reference Edition Page Montreal/IOT/2004 2 11/16

1.10 CALL ROUTING RULES Click on >> Call Routing Rules Click on Create Call Routing Rule Enable Simple Entry Mode On Name enter a name for this incoming rule example ThinkTel to Port1 On Call Comes in From enter the name of the SIP Endpoint already created ThinkTel On Send Call Through enter Port1 Click on Save Call Routing Rule Click again on Create Call Routing Rule THINKTEL COMMUNICATIONS Reference Edition Page Montreal/IOT/2004 2 12/16

Enable Simple Entry Mode On Name enter a name for this outgoing rule example Port1 to ThinkTel On Call Comes in From enter port1 On Send Call Through enter the name of the SIP Endpoint already created ThinkTel Click on Save Call Routing Rule THINKTEL COMMUNICATIONS Reference Edition Page Montreal/IOT/2004 2 13/16

1.11 CONNECTION STATUS Click on Diagnostics >> Connection Status On the Tab Network verify the connection status of the interface ETH1 (Connected) On the Tab SIP Endpoints verify the connection status of the SIP-TRUNK (registered) On the Tab T1/E1 Interfaces verify the connection status of the PRI (UP,Active) THINKTEL COMMUNICATIONS Reference Edition Page Montreal/IOT/2004 2 14/16

1.12 OUTGOING AND INCOMING CALLS Make outgoing and incoming calls Click on Reporting >> Statistics Verify the Active Calls Verify the Calls Processed 1.13 BACK UP THE CONFIGURATION Click on Maintenance >> Backups Click on Download Backup, Save the zipped File THINKTEL COMMUNICATIONS Reference Edition Page Montreal/IOT/2004 2 15/16

1.14 FIREWALL CONFIGURATION If you are connected to the proxy edm.trk.tprm.ca (208.68.17.52) Primarily assigned to Western Canada base PBX trunks you will need to allow : 1- UDP port 5060 for SIP signaling 2- UDP ports 10000-65500 for 208.68.17.32/27, 206.80.250.96/27 & 209.197.133.0/26 If you are connected to the proxy tor.trk.tprm.ca (206.80.250.100) Primarily assigned to Eastern Canada base PBX trunks you will need to allow : 1-UDP port 5060 for SIP signaling 2-UDP ports 10000-65500 for 208.68.17.32/27, 206.80.250.96/27 & 209.197.133.0/26 THINKTEL COMMUNICATIONS Reference Edition Page Montreal/IOT/2004 2 16/16