Hemodynamic Pressure and Volume Signals

Similar documents
SUMMARY. Additional Digital/Software filters are included in Chart and filter the data after it has been sampled and recorded by the PowerLab.

Connecting physiology with patient care

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

Magnetic Resonance Quantitative Analysis. MRV MR Flow. Reliable analysis of heart and peripheral arteries in the clinical workflow

Data acquisition and analysis for life science research software

Section Four: Pulmonary Artery Waveform Interpretation

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

Hemodynamic Monitoring: Principles to Practice M. L. Cheatham, MD, FACS, FCCM

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

Type-D EEG System for Regular EEG Clinic

Doppler. Doppler. Doppler shift. Doppler Frequency. Doppler shift. Doppler shift. Chapter 19

Direct Arterial Blood Pressure Monitoring Angel M. Rivera CVT, VTS (ECC) Animal Emergency Center Glendale, WI March 2003

PRODUCT SHEET OUT1 SPECIFICATIONS

Agilent 4339B/4349B High Resistance Meters

The Universal DAQ Device. Connect and measure immediately!

Product Overview 9100D

Experiment 5. Strain Gage Measurements

NEW. EVEN MORE data acquisition and test stand automation

ADINSTRUMENTS. making science easier. LabChart 7. Student Quick Reference Guide

802.11ac Power Measurement and Timing Analysis

Getting Started with. LabTutor Teaching Suite

How to Measure 5 ns Rise/Fall Time on an RF Pulsed Power Amplifier Using the 8990B Peak Power Analyzer

LMS Test.Xpress Powering personal productivity

Agilent Automotive Power Window Regulator Testing. Application Note

CardioCard System. Product Specification and Sample Reports. PC-Based ECG CardioCard. PC-Based Stress. PC-Based Holter. CardioCard.

Samba Preclin Samba 200. Product Presentation

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

Intraventricular Pressure Measurement in a Langendorff Preparation

Electrocardiogram and Heart Sounds

Research-Grade Research-Grade. Capture

Activity 4.2.3: EKG. Introduction. Equipment. Procedure

Clinical Training for Visage 7 Cardiac. Visage 7

Cable Analysis and Fault Detection using the Bode 100

Physiologic Monitoring Systems for Life Science Research. Discover the possibilities with DSI.

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Building a Simulink model for real-time analysis V Copyright g.tec medical engineering GmbH

FREQUENCY RESPONSE ANALYZERS

ZEBRAFISH SYSTEMS SYSTEMS ZEBRAFISH. Fast, automatic analyses

Section Two: Arterial Pressure Monitoring

Wireless bedside Vital Signs monitoring unit

Output Ripple and Noise Measurement Methods for Ericsson Power Modules

Fibre Optic Solutions for your Test and Instrumentation needs

Cell Phone Vibration Experiment

The Sonometer The Resonant String and Timbre Change after plucking

Milwaukee School of Engineering Case Study: Factors that Affect Blood Pressure Instructor Version

Edwards FloTrac Sensor & Edwards Vigileo Monitor. Measuring Continuous Cardiac Output with the FloTrac Sensor and Vigileo Monitor

Normal & Abnormal Intracardiac. Lancashire & South Cumbria Cardiac Network

3 rd Russian-Bavarian Conference on Bio-Medical Engineering

R&S FS-K130PC Distortion Analysis Software Amplifier modeling and linearization

WINDAQ Data Acquisition and Playback Software

Navi-Radar 4000 and Navi-Sailor 4000 ECS for workboats and small crafts BIG SOLUTIONS FOR SMALL VESSELS

Measuring Temperature withthermistors a Tutorial David Potter

VITALMONITOR SOFTWARE FOR PATIENT MONITORING

Fiber Optic Distributed Temperature Sensor (B-DTS)

AND9035/D. BELASIGNA 250 and 300 for Low-Bandwidth Applications APPLICATION NOTE

imc BUSDAQ autonomous intelligent synchronized Field bus data acquisition - from stationary to mobile imc productive testing

INNOC. Innocare-T. Innomed. Innomed s intensive and anesthesiological monitor system can be used both as a transport or bed-side care unit

Fetal monitoring on the move, from a hospital to in-home setting

Agilent AN 1315 Optimizing RF and Microwave Spectrum Analyzer Dynamic Range. Application Note

CBS RECORDS PROFESSIONAL SERIES CBS RECORDS CD-1 STANDARD TEST DISC

Paragon. Intelligent Bond Testing Software.

Agilent N2717A Service Software Performance Verification and Adjustment Software for the Agilent ESA Spectrum Analyzers Product Overview

EXPERTS IN WATER COOLING SINCE aquastream ULTIMATE SUPER SILENT PUMP TECHNOLOGY. The ultimate pump system.

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

INTERFERENCE OF SOUND WAVES

INTERFERENCE OF SOUND WAVES

imc FAMOS 6.3 visualization signal analysis data processing test reporting Comprehensive data analysis and documentation imc productive testing

Wireless Patient Monitoring

X-Series Signal Analysis. Future-ready instruments Consistent measurement framework Broadest set of applications and software

imc FAMOS 6.3 visualization signal analysis data processing test reporting Comprehensive data analysis and documentation imc productive testing

Starling s Law Regulation of Myocardial Performance Intrinsic Regulation of Myocardial Performance

Agilent 8753ET/8753ES Network Analyzers

Biology 347 General Physiology Lab Advanced Cardiac Functions ECG Leads and Einthoven s Triangle

Blast Vibration and Overpressure Monitor

SIGNAL GENERATORS and OSCILLOSCOPE CALIBRATION

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Note: The left and right sides of the heart must pump exactly the same volume of blood when averaged over a period of time

Electronics. Discrete assembly of an operational amplifier as a transistor circuit. LD Physics Leaflets P

Ultrasound Technologies. PD1v. vascular pocket doppler. Operating Instructions

MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card

Paediatric Intensive Care Unit Nursing Procedure: Care of Arterial Lines.

PowerLab Teaching Series. Owner s Guide

GDS Triaxial Automated System (GDSTAS)

TDA2822 DUAL POWER AMPLIFIER SUPPLY VOLTAGE DOWN TO 3 V LOW CROSSOVER DISTORSION LOW QUIESCENT CURRENT BRIDGE OR STEREO CONFIGURATION

Linear Parameter Measurement (LPM)

123 Main St NY, New York ph: (202) fax: (202)

LM1036 Dual DC Operated Tone/Volume/Balance Circuit

Everything you need for protection scheme testing

Trigno/Vicon System Integration

Unmatched RF Spectrum Analysis

RPS High Accuracy Resonant Pressure Sensor. GE Measurement & Control Solutions. Features:

Recommendations for TDR configuration for channel characterization by S-parameters. Pavel Zivny IEEE GCU Singapore, 2011/03 V1.

Edwards FloTrac Sensor & Edwards Vigileo Monitor. Understanding Stroke Volume Variation and Its Clinical Application

Ultrasound Distance Measurement

Network analyzer and spectrum analyzer two in one

Patient Transport. with the Automated Impella Controller

Transcription:

Hemodynamic Pressure and Volume Signals PowerLab Systems, LabChart Software and Millar Mikro-Tip and Ventri-Cath Catheters Features & Benefits n Excellent signal frequency response n No motion artifact or signal attenuation n Catheter sizes starting at 1F - the smallest available on the market n MPVS Ultra system can be used with small and large animals n LabChart PV Loop Module enables powerful online and offline analysis n AAMI recognized Gold- Standard in Pressure and Volume measurement Pressure signals recorded using a PowerLab system with a Millar Instruments Mikro-Tip catheter in the top channel and a traditional fluid-filled catheter in the bottom channel. PowerLab data acquisition systems, coupled with Millar Ventri-Cath and Mikro-Tip catheters provide researchers with cutting-edge technology to record and analyze high-fidelity cardiovascular signals. Whether in large or small animals, with the transducer located at the tip of the catheter, you are able to place the sensor directly at the source of the signal and record real-time hemodynamic variables with unparalleled accuracy. The Mikro-Tip and Ventri-Cath catheter designs offer significant advantages over traditional fluid-filled catheter models. Benefits include maintained signal integrity, no signal attenuation and the elimination of artifacts due to catheter movement. The solid state design and sensing technology of the Mikro-Tip and Ventri-Cath catheters ensure a true representation of pressure or pressure-volume signals and make them ideal for cardiovascular measurements in mice and rats through to rabbits and sheep. Data Acquisition and Analysis

The Mikro-Tip and Ventri-Cath Advantage Frequency Response Millar catheters have a high bandwidth and respond well to pressure changes at high and low frequencies without loss of information. The LabChart recording on the right compares a pressure signal measured from a common source using both a fluid-filled and a Mikro-Tip catheter. The signal recorded with the Mikro-Tip catheter is unaffected by changes in the signal frequency. In contrast, the signal recorded from a fluid-filled catheter is attenuated above 5 Hz (typical rat heart rate) and distorted further at higher frequencies such as 10 Hz (typical mouse heart rate). Signal Integrity The data on the right illustrates how poor frequency response characteristics of a transducer can affect signal integrity. Using a square wave produced by a signal generator, you can see that the Mikro-Tip catheter signal (top channel) reflects the true waveform as displayed at 1 and 5 Hz. The same signal waveform detected using a fluid-filled transducer is distorted at 1 Hz and the original waveform components are completely lost at 5 Hz. Signal Artifact Signals from fluid-filled catheters are susceptible to interference due to air-bubble dampening, catheter movement, catheter blockage, sensor positioning and the distance of the transducer from the signal source. Effects of tapping both the Mikro-Tip and the fluid-filled catheters are illustrated on the right. The signal from the Mikro-Tip catheter is unaffected, while the signal from the fluid-filled catheter is noisy. dp/dt Measurements The parameter dp/dt is commonly used as an index of cardiac contractility. It represents the change in left ventricular pressure as a function of time and is determined from the slope of the ventricular pressure waveform during systole. Maximum dp/dt is used as an index of the initial velocity of myocardial contraction. Using a fluidfilled catheter and transducer (blue signal), the recorded signal may be misrepresented resulting in inaccurate dp/dt values. Millar Pressure & PV Catheter Features n Ultra miniature catheters from 1F through to large 7F catheters n Provide minimally invasive, continuous recording of pressure or pressure-volume n PV catheter provides both pressure and volume signals n Multi-segmented platinum electrodes for variable ventricle sizes (PV catheters) n Suitable for use with multiple surgical techniques n No risk of artificial pressure or volume changes caused by catheter flexing n Suitable for in vitro studies such as working heart applications n Internationally recognized Gold-standard < 2 > Hemodynamic Pressure

Cardiovascular Pressure-Volume Systems MPVS Ultra System (Small and Large Animals) The MPVS Ultra system simultaneously and continuously measures high-fidelity left ventricular pressure (LVP) and volume from in vivo beating hearts using a single catheter with a high-fidelity pressure sensor and electrodes. Compatible with ultraminiature catheters that are ideal for transgenic mice as small as 16 grams and multisegmented catheters for large animals (domestic livestock), the MPVS Ultra provides an extensive range of cardiovascular applications. The intuitive Control Interface software streamlines setup and calibration, allows easy conversion of conductance measurements to true volume units and provides a variety of validated calibration methods. The MPVS Ultra Foundation Research System, including a PowerLab and the latest LabChart Pro software, allows you to record and analyze pressure and volume signals. The LabChart PV Loop Module allows continuous real time PV loop plots during drug and hemodynamic interventions, thereby allowing the user to monitor and evaluate the mechanical properties of the heart in both normal and abnormal states. Analysis can be performed either during or after recording. Features & Benefits n State-of-the-art technology n Suitable for small and large animal applications n Flexible volume determination using selectable catheter segments n Built-in volume calibration technique using Rho cuvette and Baan s equation n Software-controlled user interface n Dual pressure inputs n Seamless integration with PowerLab and LabChart n Compatible with all Millar small animal PV catheters and large animal Ventri-Cath PV catheters MPVS Ultra Single Segment (Small Animals) For small animal research, the MPVS Ultra Single Segment Foundation system for mice or rats provides the most economical solution to rodent pressure-volume studies. The system includes two pressure amplifiers, a single segment of volume measurement and intuitive software control, all at a fraction of the cost of comparable imaging technologies. Ventri-Cath Large Animal Pressure-Volume Catheters The Ventri-Cath is the latest multi-segment pressure-volume (PV) catheter for complete cardiovascular assessment in large animals (e.g. dogs, pigs etc.). From a single input connection, the Ventri-Cath provides real-time pressure and volume signals for complete monitoring and analysis of ventricular function. The affordability of the Ventri-Cath series increases the research community s access to Millar gold-standard pressure-volume technology. A CEC-10PV PV Extension Cable (VC to MPVS Ultra, 10ft) or 850-5140 Ventri-Cath Adaptor Cable is required for connection to recording devices. PV Applications n Baseline and occlusion PV loop analysis n Phenotyping and gene manipulation studies n Cardiac hypertrophy n Cardiovascular remodelling n Toxicology n Pharmacology (rapid drug screening) n Cardiac resynchronization therapy n Ischemia/reperfusion studies

Data Acquisition and Analysis PowerLab data acquisition systems provide recording, analysis and display of up to 32 channels simultaneously in real time with samplings speeds of up to 200 khz per channel (400 khz aggregate). They are ideal for monitoring and analyzing cardiovascular parameters including left ventricular pressure and volume, heart rate, systolic and end-diastolic pressure, rate of pressure change (dp/dt), rate of volume change (dv/dt) and more. Recording channels can be easily calibrated into meaningful units such as mmhg or ml and analysis results can be exported in a variety of formats including *.xls, *.txt or *.csv files. All PowerLab research systems come with LabChart Pro, and include cardiovascular analysis modules such as the PV Loop Module and the Blood Pressure Module. LabChart Pro also comes with 5 years of free software upgrades. PV Loop Module The PV Loop Module for LabChart records and analyzes left ventricular pressure and volume data for hemodynamic research in animals. It automatically calculates a wide range of hemodynamic variables including; stroke work and volume, cardiac output, heart rate, ejection fraction and many more. The module can be used to analyze data online or offline. The Module also allows easy conversion of data to absolute volumes using cuvette calibration and enables the researcher to correct for parallel conductance using saline calibration - all within a single data file. Features Loop View n Examine individual loops n Select or exclude loops from analysis n Calculate and display End-systolic and End-diastolic PV relationships Easy Calibration n Cuvette calibration can be computed and applied to the volume channel n Built-in settings files with known volumes of common cuvettes provided n Multiple calibration methods fully supported e.g. saline or cuvette calibration Multiple Plots and regression analysis including: n Preload-recruitable stroke work (PRSW) n dp/dt max vs. End Diastolic Volume (EDV) n Pressure Volume Area (PVA) vs. EDV n PVA vs. End Systolic Pressure ESP Total Compatibility n Export PV Loop data from the Data Pad as *.xls, *.txt or *.csv files n Synchronize PV Loop with Movie View and playback PV Loop data alongside video Data Acquisition and Analysis < 4 >

Data Acquisition and Analysis Blood Pressure Module The Blood Pressure Module for LabChart (Windows) provides real time or offline automated detection and analysis of a range of cardiovascular parameters from arterial or ventricular pressure signals as shown below. Table View Options for Ventricular Pressure and a Blood Pressure Table View generated by the Blood Pressure Module for LabChart. Pressure & Pressure Volume Catheters The following is a selection of Mikro-Tip and Ventri-Cath Catheters. For more options or to discuss your particular application please contact your nearest ADInstruments representative. Pressure Catheters SPR-1000 Pressure Catheter (1F, Single, Straight, PI, 20cm)* SPR-671 Pressure Catheter (1.4F, Single, Straight, Ny, 15cm) SPR-407 Pressure Catheter (2F, Single, Straight, Ny, 140 cm) SPR-320 Pressure Catheter (2F, Single, Straight, PU, 140cm) SPR-882 Pressure Catheter (3F, Single, Straight, Ny, 140cm) SPR-721 Pressure Catheter (2.5F, Dual, Straight, PU, 135cm) SPR-524 Pressure Catheter (3.5F, Single, Straight, Ny, 100cm)* SPR-340 Pressure Catheter (4F, Single, Curved, PU/W, 120cm) MPR-500 Pressure Catheter (5F, Single, PU, 70cm)* SPR-350 Pressure Catheter (5F, Single, Curved, PU/W, 120cm) SPR-360 Pressure Catheter (6F, Single, Curved, PU/WD, 120cm) SPR-370 Pressure Catheter (7F, Single, Curved, PU/WD, 120cm) Mouse Pressure-Volume Catheters PVR-1030 Mouse PV Catheter (1F, 4E, 3.0mm, 4.5cm, PI)* PVR-1035 Mouse PV Catheter (1F, 4E, 3.5mm, 4.5cm, PI)* PVR-1045 Mouse PV Catheter (1F, 4E, 4.5mm, 4.5cm, PI)* SPR-839 Mouse PV Catheter (1.4F, 4E, 4.5mm, 4.5cm, PI) SPR-853 Mouse PV Catheter (1.4F, 4E, 4mm, Taper) SPR-864 Mouse PV Catheter (1.4F, 2P, 4E, 4.5mm, Carotid) SPR-848 Mouse PV Catheter (1.4F, 2P, 4E, 4.5mm, Apical) SPR-866 Mouse PV Catheter (1.4F, 6E, Selectable Seg, 4mm/6mm) Rat Pressure-Volume Catheters SPR-847 Rat PV Catheter (1.4F, 4E, 9mm, PI, 15cm) SPR-869 Rat PV Catheter (2F, 4E, 6mm, PI, 15cm) SPR-838 Rat PV Catheter (2F, 4E, 9mm, PI, 15cm) Rat Pressure-Volume Catheters cont. SPR-878 Rat PV Catheter (2F, 4E, 12mm, PI, 15cm) SPR-858 Rat PV Catheter (2F, 4E, 14mm, PI, 15cm) SPR-901 Rat PV Catheter (2F, 2P, 4E, 9mm, Carotid, 15cm) SPR-902 Rat PV Catheter (2F, 2P, 4E, 9mm, Apical, 15cm) SPR-819 Rat PV Catheter (1.4F, 6E, Selectable Seg, 9mm/14mm) Multi-Segmented Pressure Volume Catheters SPR-877 PV Catheter (3F, 10E, 2.5mm, DField, 120cm) SPR-889 PV Catheter (3F, 10E, 3mm, SField, U-tip, 80cm) SPR-894 PV Catheter (3F, 10E, 4mm, DField, U-tip, 80cm) Recommended for dogs, pigs and sheep VENTRI-CATH-507 Ventri-Cath Catheter (5F, 12E, 7mm, DField, Pigtail, 122cm) VENTRI-CATH-507S Ventri-Cath Catheter (5F, 12E, 7mm, DField, Straight, 122cm) VENTRI-CATH-510 Ventri-Cath Catheter (5F, 12E, 10mm, DField, Pigtail, 122cm) VENTRI-CATH-510S Ventri-Cath Catheter (5F, 12E, 10mm, DField, Straight, 122cm) VENTRI-CATH-512 Ventri-Cath Catheter (5F, 12E, 12mm, DField, Pigtail, 122cm) VENTRI-CATH-512S Ventri-Cath Catheter (5F, 12E, 12mm, DField, Straight, 122cm) VENTRI-CATH-515 Ventri-Cath Catheter (5F, 12E, 15mm, DField, Pigtail, 122cm) VENTRI-CATH-515S Ventri-Cath Catheter (5F, 12E, 15mm, DField, Straight, 122cm) SPR-562-1 PV Catheter (6F, 2P, 12E, 7mm, DField, Pigtail, PU, 125cm)* 1F= 0.33 mm E= Electrode number P= Pressure transducer number *= Non-repairable Note: Catheter interface cables are required for connection to ADInstruments Bridge Amplifiers < 5 > Hemodynamic Pressure

Ordering Information ADInstruments Foundation Systems ADInstruments provides both Pressure and Pressure-Volume Foundation Systems. To allow full customization of each system, the Mikro-Tip Catheters need to be selected separately. If you need assistance with selecting the appropriate catheters for your application please do not hesitate to contact us. PL3508B35 Mikro-Tip Blood Pressure Foundation System 1 x PL3508 PowerLab 8/35 Series with LabChart (Win & Mac) 1 x MLS260/7 LabChart Pro software 1 x ML221 Bridge Amp 1 x AEC-10C Catheter Interface Cable 1 x AEC-10D Catheter Interface Cable PL3508B48/M MPVS Single Segment Foundation System for Mice PL3508B48/R MPVS Single Segment Foundation System for Rats Both Systems Include: 1 x PL3508 PowerLab 8/35 Series with LabChart (Win & Mac) 1 x MLS260/7 LabChart Pro software 1 x 880-0168SS MPVS-Ultra Single Segment Pressure-Volume Unit 1 x 880-0170BNC MPVS-Ultra Single Segment Cable Pack 1 x 910-1048 Volume Calibration Cuvette (Rat PV Catheters) (with PL3508B48/R only) 1 x 910-1049 Volume Calibration Cuvette (Mouse PV catheters) (with PL3508B48/M only) PL3516B49 MPVS Ultra Foundation System 1 x PL3516 PowerLab 16/35 Series with LabChart (Win & Mac) 1 x MLS260/7 LabChart Pro software 1 x 880-0168 MPVS-Ultra Pressure-Volume Unit (large and small animals) 1 x 910-1060 Rho Calibration Cuvette kit 1 x 880-0169 MPVS-Ultra Cable Pack (3m) required for connecting PV catheters to the MPVS-Ultra Pressure-Volume Unit Includes: 1x CEC-10E PV Extension Cable (3 m) for pressure and volume measurement 1x PEC-10D Pressure Extension Cable (3 m) for 2nd sensor pressure measurement 1 x 880-0172 MPVS-Ultra BNC Cable pack required for connecting the MPVS-Ultra Additional Items 880-0168U MPVS Ultra Upgrade (Converts SS Unit to MS Unit) for small & large animals 910-1049 Volume Calibration Cuvette (1.5 to 4.0 mm) 910-1048 Volume Calibration Cuvette (2 to 15 mm) 910-1060 Rho Calibration Cuvette Kit Software MLS060/7 LabChart (Win and Mac) MLS330/7 GLP Client and MLS335 GLP Server (Win) MLS260/7 LabChart Pro (Includes the modules listed below. Modules are also available for individual purchase.) MLS390/7 Dose Response (Win) MLS310/7 Heart Rate Variability (Win and Mac) MLS340/7 Cardiac Output (Win) MLS065/7 DMT Normalization (Win and Mac) MLS240/7 Metabolic (Win and Mac) MLS320/7 Video Capture (Win and Mac) MLS370/7 Blood Pressure (Win) MLS062/7 Spike Histogram (Win and Mac) MLS395/7 Circadian Analysis (Win) MLS360/7 ECG Analysis (Win) MLS380/7 Peak Analysis (Win) MLS375/7 PV Loop (Win) ADInstruments also offers solutions for researchers working in GLP and 21 CFR Part 11 environments. Please contact your ADInstruments representative for more information. PowerLab, MacLab, LabChart, LabTutor and LabAuthor are registered trademarks and Chart and Scope are trademarks of ADInstruments Pty Ltd. All other trademarks are the property of their respective owners. HDYN08/11 PowerLab systems and signal conditioners meet the European EMC directive. ADInstruments signal conditioners for human use are approved to the IEC60601-1 patient safety standard and meet the CSA C22.2 No. 601.1-M90 and UL Std No. 2601-1 safety of medical electrical equipment standards. GLP 21CFR Part11 Compliance North America Tel: +1 888 965 6040 Fax: +1 719 576 3971 info.na@adinstruments.com United Kingdom Tel: +44 1865 332 050 Fax: +44 1865 332 051 info.uk@adinstruments.com Germany Tel: +49 6226 970105 Fax: +49 6226 970106 info.de@adinstruments.com North Asia Tel: +86 21 5830 5639 Fax: +86 21 5830 5640 info.cn@adinstruments.com ISO 9001:2008 Certified Quality Management System South East Asia Tel: +60 3 8024 5296 Fax: +60 3 8023 6307 info.sea@adinstruments.com Japan Tel: +81 52 932 6462 Fax: +81 52 932 6755 info.jp@adinstruments.com South America Tel: +56 2 356 6749 Fax: +56 2 356 6786 info.cl@adinstruments.com Brazil Tel: +55 11 3266 2393 Fax: +55 11 3266 2392 info.br@adinstruments.com South Asia IN Tel: +91 11 4306 5615 PK Tel: +92 21 3489 2518 info.in@adinstruments.com Australia Tel: +61 2 8818 3400 Fax: +61 2 8818 3499 info.au@adinstruments.com New Zealand Tel: +64 3 477 4646 Fax: +64 3 477 4346 info.nz@adinstruments.com International Tel: +61 2 8818 3400 Fax: +61 2 8818 3499 info.au@adinstruments.com