Determination of Volatiles in Beer using Solid-Phase Microextraction in Combination with Gas Chromatography/Mass Spectrometry



Similar documents
1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.

Analyzing Small Molecules by EI and GC-MS. July 2014

Analysis of Organophosphorus Pesticides in Milk Using SPME and GC-MS/MS. No. GCMS No. SSI-GCMS Shilpi Chopra, Ph.D.

AppNote 6/2003. Analysis of Flavors using a Mass Spectral Based Chemical Sensor KEYWORDS ABSTRACT

Aromatic plants: from extraction to analysis

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

Gas Chromatography. Let s begin with an example problem: SPME head space analysis of pesticides in tea and follow-up analysis by high speed GC.

Expectations for GC-MS Lab

Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection

The Characterization of Perfume Fragrances Using GC/MS, Headspace Trap and Olfactory Port

AN INTRODUCTION TO HEADSPACE SAMPLING IN GAS CHROMATOGRAPHY FUNDAMENTALS AND THEORY. Andrew Tipler

Fractional Distillation and Gas Chromatography

ALLERGENS IN PERFUMES: GAS CHROMATOGRAPHY^ MASS SPECTROMETRY

Chemical Analysis of Chardonnay Wines: Identification and Analysis of Important Aroma Compounds

Analysis of Liquid Samples on the Agilent GC-MS

A VISION to On-Line SPE PTV GC MS Determination of Organic Micro Pollutants in Surface Water

ACETALDEHYDE and ISOVALERALDEHYDE (Gas Chromatography)

Fast Continuous Online Analysis of VOCs in Ambient Air using Agilent 5975T LTM GC/MSD and Markes TD

Purification of reaction mixtures using flash chromatography.

Analysis of Phthalate Esters in Children's Toys Using GC-MS

Technical Report. Automatic Identification and Semi-quantitative Analysis of Psychotropic Drugs in Serum Using GC/MS Forensic Toxicological Database

SUCRALOSE. White to off-white, practically odourless crystalline powder

Major and Minor Compounds in a Mexican Spirit, Young Mezcal Coming from Two Agave Species

Application of TargetView software within the food industry - the identi cation of pyrazine compounds in potato crisps

Chemical analysis service, Turner s Green Technology Group

AppNote 2/2012. Determining Phenolic Compounds in Whisky using Direct Large Volume Injection and Stir Bar Sorptive Extraction KEYWORDS ABSTRACT

Headspace Gas Chromatography Profiles of Fruit-Flavored Malt Beverages Using Solid-Phase MicroExtraction

6. ANALYTICAL METHODS

α-cyclodextrin SYNONYMS α-schardinger dextrin, α-dextrin, cyclohexaamylose, cyclomaltohexaose, α- cycloamylase

Enhancing GCMS analysis of trace compounds using a new dynamic baseline compensation algorithm to reduce background interference

Application Note # MS-14 Fast On-site Identification of Drugs with the mobile GC/MS system E²M

ß-CYCLODEXTRIN SYNONYMS

Gas Chromatography Liner Selection Guide

Pesticide Analysis by Mass Spectrometry

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep

Intelligent use of Relative Response Factors in Gas Chromatography-Flame Ionisation Detection

WHITE PAPER CONTINUOUS AIR MONITORING USING GRIFFIN 460 MOBILE GC/MS. HEADINGS: ALL CAPS, 12 PT TREBUCHET FONT, ICx BLUE

SIMULTANEOUS DETERMINATION OF NALTREXONE AND 6- -NALTREXOL IN SERUM BY HPLC

GC/MS Analysis of Vanillin and Ethyl Vanillin in Distilled Spirits

Determination of Haloacetic Acids and Dalapon in Drinking Water by SPE and GC/ECD*

Background Information

Theory and Instrumentation of GC Introduction

THERMAL DESORPTION. Introduction and Principles. Focusing on Volatiles

PLOT Columns. Top: Bob Langford, GC Column Manufacturing Technician Bottom: Stephanie Sunner, Customer Service Representative

Enhancing Utility and Throughput of SPME using Advanced Automation Strategies

POLYVINYL ALCOHOL. SYNONYMS Vinyl alcohol polymer, PVOH, INS No DEFINITION DESCRIPTION FUNCTIONAL USES CHARACTERISTICS

TABLE OF CONTENTS CHAPTER TITLE PAGE DECLARATION ACKNOWLEDGEMENT ABSTRACT LIST OF TABLES LIST OF FIGURES LIST OF SYMBOLS LIST OF APPENDICES

How To Test For Contamination In Large Volume Water

Chemical Profiling and Differential Analysis of Whiskies Using Orbitrap GC-MS

Method development for analysis of formaldehyde in foodsimulant. melamine-ware by GC-MS and LC-MS/MS. Internal Technical Report

III Analytical Methods

An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols.

Holcim EMR List of EN Standards and VDI Guidelines usable for Discontinuous Measurements in Cement Plants

Determination of N-cyclohexyl-diazeniumdioxide (HDO) containing compounds in treated wood using GC-MS

GC METHODS FOR QUANTITATIVE DETERMINATION OF BENZENE IN GASOLINE

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY

Evaluation of headspace Solid Phase Micro-extraction method for analysis of phosphine residues in wheat

Multi-Shot Pyrolyzer EGA/PY-3030D. Flexible Versatile Reproducible

# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water

1.2 This TAP is applicable to concrete, charcoal, coral, debris, wipes and soil.

Oasis HLB Cartridges and 96-Well Plates

GC/MS BATCH NUMBER: CK0102

AMD Analysis & Technology AG

Bologna Maggio 2011; 1 MS Environmental Day

Extraction, Derivatization and Ultra-Sensitive GC/Triple Quadrupole Analysis of Estrone and Estradiol in Human Serum

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

EPA Method RSK 175 Dissolved Gasses in Water Matrices using the Teledyne Tekmar HT3 Headspace Analyzer. HT3 Application Note.

Gas Chromatography. Gas Chromatograph

Name Lab #3: Solubility of Organic Compounds Objectives: Introduction: soluble insoluble partially soluble miscible immiscible

GCxGC COUPLED TO FAST SCANNING QUADRUPOLE MS FOR TRACE ANALYSIS OF POPs

Opiates in Urine by SAMHSA GC/MS

Quantitative Evaluation of Perfume Fleuressence Samples using the znose

Thermo Scientific HyperSep Solid Phase Extraction Method Development Guide

MEPS - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process

Extraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis

Application Note. Determination of Nitrite and Nitrate in Fruit Juices by UV Detection. Summary. Introduction. Experimental Sample Preparation

Unit title: Chemical Laboratory Techniques

Indoor Air Comfort Test Report

GLYCOLS IN NATURAL GAS EXPERIMENTS, MODELLING AND TRACKING

Ferda ORHUN Mineral Research and Exploration Institute of Turkey

Development and Validation of Gas Chromatographic Analytical Method for Estimation of Residual Solvents in Excipients (Klucell, Triacetan, HPMC)

105 Adopted:

This study was performed by Patrick Sullivan and staff at TestAmerica Analytical Testing Corp., Westfield, MA, USA

Lecture Chromo-3: Gas Chromatography. CHEM 5181 Fall 2004 Mass Spectrometry & Chromatography. Jessica Gilman and Prof. Jose-Luis Jimenez CU-Boulder

Develop a Quantitative Analytical Method for low (» 1 ppm) levels of Sulfate

MINERAL OIL (MEDIUM VISCOSITY)

GC-IMS Technology for Efficient Quality Control

SPE and HPLC. Dr Iva Chianella Lecturer in Analytical Chemistry Cranfield Health +44 (0)

MASS SPECTROMETRIC IDENTIFICATION OF SOME SULPHUR CONTAINING PHENALKYLAMINE DESIGNER DRUGS *

ANALYSIS OF ASPIRIN INFRARED (IR) SPECTROSCOPY AND MELTING POINT DETERMINATION

Czech J. Food Sci. Vol. 25, No. 5:

New drugs of abuse? A case study on Phenazepam & Methoxetamine

A Comparison between EPA Compendium Method TO- 15 and EPA Method 8260B for VOC Determination in Soil Gas

GUIDELINES ON THE USE OF MASS SPECTROMETRY (MS) FOR IDENTIFICATION, CONFIRMATION AND QUANTITATIVE DETERMINATION OF RESIDUES CAC/GL

Transcription:

Czech J. Food Sci. Vol. 32, 2014, No. 3: 241 248 Determination of Volatiles in Beer using Solid-Phase Microextraction in Combination with Gas Chromatography/Mass Spectrometry Jana KLEINOVÁ 1,2 and Bořivoj KLEJDUS 1,2 1 Department of Chemistry and Biochemistry, Faculty of Agronomy and 2 CEITEC Central European Institute of Technology, Mendel University in Brno, Brno, Czech Republic Abstract Kleinová J., Klejdus B. (2014): Determination of volatiles in beer using solid-phase microextraction in combination with gas chromatography/mass spectrometry. Czech J: Food Sci., 32: 241 248. Headspace solid phase microextraction and purge and trap analysis were used for the determination of volatiles in beer. These methods were compared with the analysis of unconcentrated gas phase and liquid extraction. Solid phase microextraction proved to be the most useful and was investigated more closely. Volatiles were isolated by the means of different combinations of sorbents, sorption was performed at various temperatures and times. The addition of salt to the sample and stirring of the sample were examined to enhance the analyte concentration in the gas phase. Ultrasonic bath and filtration were tested to remove carbon dioxide. Not all methods improved the sorption of volatiles. Stirring was characterised by low repeatability and ultrasonic bath causes to the loss of volatile analytes. Distribution constants of volatiles depend on their boiling points and thus different sorption temperatures are suitable for different substances. Keywords: GC; headspace technique; solid phase; microextraction; volatile compounds Volatile compounds in beer are substances that contribute significantly to the organoleptic properties of beverages and thus affect product quality both in a positive and negative way. The Maillard reaction products are formed during kilning and roasting of malt. The temperature of 125 160 C is the most favourable for the formation of flavour. Intermediate chromophores are more sensory active than the final reaction products the melanoidins (Coghe et al. 2004; Cramer et al. 2005). Essential oils, which are released to the wort during brewing, are another group of volatile compounds in hops. The most important phase in terms of volatile substances is a fermentation process when a lot of compounds with low boiling point are formed (Kovačevič & Kač 2001; Lermusieau et al. 2011). The best technique for the determination of volatile compounds in beer is gas chromatography. Due to the complex matrix of beer and a large concentration range among the substances the analytes must be isolated and concentrated first. Liquid extraction, distillation, supercritical fluid extraction, solid phase extraction, stir bar sorptive extraction or headspace techniques are used for the sample preparation. The most popular is solid phase microextraction (SPME). During SPME the analytes are sorbed to the small amount of extraction phase on the surface of the fibre. The fibre is ejected directly into the sample or into the gas phase above the sample (headspace), which is preferable for the analysis of volatile compounds in beer (Kolb 1999; Štěrba et al. 2011; Pawliszyn 2000; Wardecki et al. 2003). Supported by the Internal Grant Agency, Mendel University in Brno; the work was realised in CEITEC Central European Institute of Technology, supported by the Project CZ.1.05/1.1.00/02.0068 from the European Regional Development Fund. 241

Vol. 32, 2014, No. 3: 241 248 Czech J. Food Sci. MATERIAL AND METHODS Materials. All chemicals were purchased from Sigma Aldrich (St. Louis, USA) and were of the highest purity available. Nitrogen (5.0) and helium (5.5) were purchased from SIAD (Braňany, Czech Republic). Bottled beer (Starobrno, Brno, Czech Republic) was used for the method optimisation. It is a pilsner type beer containing 4% (v/v) alcohol. Liquid extraction. Hexane and dichloromethane were examined as suitable solvents for liquid extraction. Samples were prepared in 40 ml vials from 15 ml of beer and 15 ml of solvent. For optimisation of extraction conditions different amounts of salt (5, 10, and 15 g) were added. Samples were extracted in an ultrasonic bath (Kraintek, Hradec Králové, Czech Republic) for 10 minutes. Subsequently, extracts were spun in the centrifuge (MPW Med. Instruments, Warsaw, Poland) at 18 000 per min for 5 minutes. Static headspace analysis (SHS). The sample for SHS was prepared from 5 ml of beer and 2 g of NaCl in a 15-ml vial, heated at 50 C for 30 minutes. Then 25 µl sample of the gaseous phase was taken with a gastight syringe (Hamilton, Reno, USA) and injected immediately. Purge and trap (P&T) analysis. During the P&T analysis 10 ml of the sample was exposed to inert gas nitrogen bubbling through the liquid in a strip tube. Exposure time was 30 min, nitrogen flow rate was 10 ml/minutes. After completing the exposure time, the sorption tube was placed in a module for the fully automatic thermal desorption of the sample, Model TD-4 (Scientific Instrument Services, Ringoes, USA). The thermodesorption tube was filled with 100 mg of Tenax (Scientific Instrument Services). Thermal desorption lasted 3 min, initial temperature was 200 C and it was immediately raised at the rate of 20 C/min to 250 C. SPME analysis. Unless stated otherwise, samples were prepared from 5 ml of beer in a 15-ml vial containing 2 g NaCl. All sample vials were equilibrated for 10 min at 50 C on a heating plate with an electronic contact thermometer (IKA-Werke GmbH, Staufen, Germany) followed by fibre exposure to the headspace for 20 minutes. SPME fibre holder (manual) and 100 µm polydimethylsiloxane coated fibre were used for the SPME method (Supelco, Bellefonte, USA). Stirring with a magnetic stirrer was examined during the equilibration time. Samples were stirred during heating on the heating plate at a speed of 100 per minute. Ultrasonic bath degassing and filtration through filter paper of type 388 and 390 (Filtrak, Wiesenbad, Germany) were tested. For the optimisation of SPME conditions different amounts of beer (2.5, 5, 7.5, and 10 ml) were prepared for SPME sorption. The amount of NaCl was another investigated sampling parameter; different amounts of NaCl (1, 2, 3, 4, 5 g) were added to the sample with 5 ml of beer. Samples were retained for 24 h in the refrigerator before analysis. Sorption time was also tested: 10, 20, 30, 40, 60, 90 and 120 min at 50 C. The sample was equilibrated for 10 min at 50 C before sorption. To optimise the temperature used for the extraction of volatile substances, the samples were heated on a heating plate and the temperature of the samples was measured using an electronic contact thermometer. Temperature of the heating plate was set to 40, 50, 60, 70, 80, 90, 100, 110, and 130 C. Actual temperature of the sample was 32, 38, 45, 52, 57, 62, 68, 72, and 84 C. To determine the most suitable volume of vials, standard vials with a capacity of 15 (20 mm o.d.), 20 and 40 ml (23 mm o.d.) were used. Beer samples (5 and 10 ml) were measured in vials with capacity of 15, 10, and 15 ml beer samples were tested in vials with capacity of 20 ml, 30 ml beer samples were prepared in vials with capacity of 40 ml. SPME sorption was carried out at 70, 80, and 100 C. The electronic contact thermometer measured the actual temperature of the sample and its changes due to changes in the sample volume. Polydimethylsiloxane (PDMS), divinylbenzene (DVB), and carboxen (CAR) sorbents were used for SPME. The fibres tested for the extraction of volatile compounds were as follows: 100 μm PDMS, 65 μm PDMS/DVB, and 75 μm CAR/PDMS (Supelco, Bellefonte, USA). Each analysis was undertaken triplicate using different vials. Gas chromatography. Gas chromatography with mass spectrometry (GC-MS) and gas chromatography with flame ionisation detector (GC-FID) were compared. Samples for testing were extracted by SPME and prepared in the same way as samples used for the optimisation of SPME conditions. An HP-6890 gas chromatograph with an HP-5973 mass spectrometric detector was used for GC-MS. GC-FID was performed using HP-4890D. The HP-5973 detector was used in a classic electron impact mode. The electron ionizing energy was 70 ev. The temperature of the ion source was 230 C. Qualitative analysis was done by a comparison of the mass spectrum of volatile analytes (G1036A NIST Chem. Library) and 242

Czech J. Food Sci. Vol. 32, 2014, No. 3: 241 248 15SE+4 10SE+4 SE+4 0 8.00 10.00 12.00 14.00 16.00 (min) Figure 1. Chromatogram of volatile compounds in beer obtained using SHS: (1) 1-butanol, 3-methyl-, acetate; (2) nonanal; (3) phenylethyl alcohol; (4) octanoic acid, ethyl ester; (5) decanal; (6) decanoic acid, ethyl ester; (7) dodecanal; (8) 2-propenamide, 2-methyl-N-phenyl-; (9) dodecanoic acid, ethyl ester; (10) octadecanal; (11) cyclododecane; (12) dibutyl phthalate; (13) nonadecane corresponding peaks in the beer sample. The mass spectrometric detector operated in a scan mode at m/z 35 200. The scan time was 0.2 s, peak areas were calculated from the total ion current. The gas chromatograph was controlled by ChemStation software (Version A.03.00; Agilent, Waldbronn, Germany). Three types of chromatography columns were tested on GC-MS: HP-5MS (5% phenylmethylsiloxane, 30 m 0.25 mm i.d. 0.25 μm), DB-WAX (polyethylene glycol, 30 m 0.25 mm i.d. 0.25 µm) and HP-5MS of 60 m in length (Agilent, Waldbronn, Germany). The basic temperature programme was as follows: T 1 = 40 C, t 1 = 5 min, 20 C/min to T 2 = 250 C, t 2 = 5 minutes. Two temperature programmes with gradual increase were tested: T 1 = 40 C, t 1 = 5 min, 10 C/min to T 2 = 270 C, t 2 = 5 min and T 1 = 40 C, t 1 = 5 min, 5 C/min to T 2 = 200 C, t 2 = 5 min, 15 C/min to T 3 = 250 C, t 3 = 1 minute. Samples were injected in a splitless mode. The flow rate was 1 ml/min, injector temperature 240 C and temperature of the detector 250 C. RESULTS AND DISCUSSION Comparison of sample preparation methods Liquid extraction. In comparison with SPME, liquid extraction was totally unsatisfactory. The 15SE+4 10SE+4 SE+4 0 8.00 10.00 12.00 14.00 16.00 (min) Figure 2. Chromatogram of volatile compounds in beer obtained using SPME: (1) 1-butanol, 3-methyl-, acetate; (2) myrcene; (3) hexanoic acid, ethyl ester; (4) phenylethyl alcohol; (5) octanoic acid, ethyl ester; (6) acetic acid, octyl ester; (7) acetic acid, 2-phenylethyl ester; (8) nonanoic acid, ethyl ester; (9) citronellyl acetate; (10) 9-decenoic acid, ethyl ester; (11) decanoic acid, ethyl ester; (12) octanoic acid, 3-methylbutyl ester; (13) humulene; (14) dibutylhydroxytoluene; (15) dodecanoic acid, ethyl ester 243

Vol. 32, 2014, No. 3: 241 248 Czech J. Food Sci. 250E+6 200E+6 150E+6 100E+6 50E+6 000E+0 0 1 2 3 4 5 NaCl amount (g) Figure 3. The effect of ionic strength increase on the extraction efficiency of solid phase microextraction (SPME). Sodium chloride was added to 5 ml of beer in a 15-ml vial (y-axis: total volatile compounds expressed as peak area arbitrary) dichloromethane extracted 8 volatiles and hexane extracted 10 volatiles, which is less than one third of volatile substances extracted by SPME. However, it can be used to reduce the costs of analysis in cases where the analytes of interest are among the compounds that are extracted well. Salting out increased the sensitivity of the method. The obtained relative areas for the sample were 73, 96, 100, and 99% for dichloromethane and 34, 71, 90, and 100% for hexane thanks to the increasing amount of salt. SHS. SPME is used for the preconcentration of analytes, so it can be assumed that SPME is more suitable for the analysis of volatile compounds than SHS. On the other hand, it is not possible to ensure the transfer of all the substances by SPME because it is dependent on the affinity of the analytes to the sorbent. Analyses showed that none of the required analytes was missing when using SPME. Figures 1 Table 1. Comparison of the repeatability of solid phase microextraction (SPME) without stirring and SPME with stirring during 20 minutes of extraction Compound SPME without stirring RSD a (%) SPME with stirring during equilibration RSD (%) 1-Butanol, 3-methyl-, acetate 3.75 21.43 Hexanoic acid, ethyl ester 3.29 34.09 Phenylethyl alcohol 8.41 14.91 Octanoic acid, ethyl ester 7.34 16.55 Acetic acid, 2-phenethyl ester 5.66 53.67 9-Decenoic acid, ethyl ester 5.97 23.81 Decanoic acid, ethyl ester 3.11 23.27 Dibutylhydroxytoluene 5.10 7.34 Dodecanoic acid, ethyl ester 4.48 16.88 a relative standard deviation (estimated for peak areas, n = 5) and 2 show the volatile analytes detected after direct sampling and volatile substances detected from the PDMS SPME fibre. The source of contaminating compounds 8, 11, and 12 from Figure 1 is urban air pollution. P&T. SPME is preferable for the isolation of hop essential oils and products of fermentation. P&T is a better method for the isolation of Maillard reaction products such as maltol, furfural and 2-furanmethanol. SPME. SPME was determined to be the most effective method and became a subject of further optimisation. At first the effect of ionic strength increase on the extraction efficiency of SPME was evaluated. According to Jelen (1998) peak areas of all analysed compounds increased with increasing 35E+6 30E+6 25E+6 20E+6 15E+6 10E+6 5E+6 000E+0 1-Butanol, 3-methyl-, acetate Hexanoic acid, ethyl ester Octanoic acid, ethyl ester Acetic acid, 2-phenethyl ester 2.5 ml 5 ml 7.5 ml 10 ml Decanoic acid, ethyl ester Dodecanoic acid, ethyl ester Figure 4. The effect of sample amount on the extraction efficiency of SPME. Beer samples were processed in a 15-ml vial 244

Czech J. Food Sci. Vol. 32, 2014, No. 3: 241 248 Boiling point Optimal temperature Figure 5. Optimal extraction temperature for volatiles according to retention time (t R ) Temperature ( C) Volatile compounds Optimal extraction temperature Rf (min) Boiling point ( C) 1-Butanol, 3-methyl 4.32 38 132 1-Butanol, 3-methyl-, acetate 7.54 38 142 Hexanoic acid, ethyl ester 9.17 38 170 Phenylethyl alcohol 10.39 38 219 Octanoic acid, ethyl ester 11.02 45 230 Acetic acid, 2-phenethyl ester 11.53 52 238 Decenoic acid, ethyl ester 12.47 72 245 Tetradecanoic acid, ethyl ester 14.83 84 309 Hexadecanoic acid, ethyl ester 16.03 84 352 Retention time (min) salt concentration. Figure 3 shows the increase of detector response after sodium chloride addition to analysed beer. Addition of sodium chloride to samples lowers detection limits of the SPME method. It may be helpful for the analysis of compounds contained in trace quantities that are the main point of interest. Figure 4 shows the effect of sample amount on the extraction. SPME adsorption increased with increasing sample amount. However, the volume of the vial is more important for extraction efficiency than the sample volume. Extraction efficiency of 20 ml beer in a 40-ml vial was worse than that of 10 ml beer in a 15-ml vial. It depends on phase rations. The headspace volume should be smaller than the volume of the sample. Analytes are more concentrated in the headspace of small volume and the efficiency of SPME is higher. A comparison of the analysis of 10 ml beer in a 15-ml vial and 30 ml beer in a 40-ml vial proved that a smaller volume of the sample was preferred. The vial diameter also influences SPME adsorption. 10 ml of beer was processed to 15- and 20-ml vials of larger diameter. Some compounds showed higher recovery using the 20-ml vial although there was a larger volume of the headspace. On the other hand, there is a larger surface area that facilitates the transfer of volatile substances in the gas phase in the given time. Thus, thanks to the larger active surface the equilibrium is reached sooner and the extraction time can be adequately shorter. It enables to use more favourable extraction times for substances that work well with the higher headspace volume, which is very useful in the case of large monitoring studies of many samples. The optimal temperature for SPME sorption of individual volatiles in beer can be seen in Figure 5. It depends on boiling points of analytes. The sorption of volatiles is proportional to their concentration in the headspace. The concentration of volatiles with lower boiling point in the headspace is higher using a lower temperature because their vapour pressure is higher. The retention time of all analysed compounds increased with increasing boiling point because partition and diffusion coefficients of analytes depend on temperature. Therefore a lower temperature of SPME sorption is more suitable for compounds with low retention time and conversely. The lowest tested temperature (32 C) is not suitable for any analysed substance. 38 C is the most suitable for phenylethyl alcohol and compounds with lower boiling points. Higher temperatures of SPME sorption are preferable for volatiles with higher boiling points. The highest temperature suitable for SPME is 84 C. The extent of SPME adsorption increased rapidly with increasing the fibre exposure time from 10 to 40 minutes. The efficiency of SPME adsorption was highest after 60 minutes. It remained constant with longer exposure time. The dependence of analyte adsorption on the exposure time is shown in Figure 6. Analysed compounds are given in order according to the boiling point (upper compounds have the lower boiling points). Differences in the exposure time are largest for volatiles with higher boiling points. The use of longer exposure time is more important for SPME adsorption of volatiles with higher boiling points. Other groups of researchers came to similar results (Jelen et al. 1998; Pinho et al. 2006). According to the literature an ultrasonic bath is usually used for removing carbon dioxide (Silva et al. 2008; Rodrigues et al. 2011). However, volatiles were detected in lower concentrations after the ultrasonic 245

Vol. 32, 2014, No. 3: 241 248 Czech J. Food Sci. Table 2. GC column and solid phase microextraction (SPME) fibre used for volatile identification Compound Retention time on GC column (min) Relative areas achieved using different SPME fibre (%) DB-WAX 5MS(30) 5MS(60) D/C/P P/D C/P Ethanol 2.23 3.25 3.97 96 37 100 Ethyl acetate 4.11 4.81 100 24 76 1-Butanol, 3-methyl- 4.80 5.89 6.80 100 42 44 1-Butanol, 2-methyl- 5.95 6.87 100 70 72 Acetic acid, butyl ester 6.66 7.54 100 47 1-Pentanol 6.67 Butanoic acid, ethyl ester 7.32 8.06 100 35 61 1-Butanol, 3-methyl-, acetate 6.74 9.53 10.22 100 51 43 1-Butanol, 2-methyl-, acetate 9.57 10.29 100 43 59 Myrcene 13.14 13.82 100 51 Hexanoic acid, ethyl ester 7.31 13.41 14.05 100 39 39 Octanoic acid, ethyl ester 12.35 19.65 20.25 100 65 43 Acetic acid, octyl ester 13.31 20.59 100 53 Acetic acid, hexyl ester 13.83 14.48 100 2,3-Butanediol 14.98 1-Octanol 15.74 16.35 100 48 Heptanoic acid, ethyl ester 16.56 17.18 100 50 Linalool 15.13 16.70 17.35 100 35 59 Acetic acid, heptyl ester 16.99 17.62 100 62 47 Decanoic acid, ethyl ester 17.22 25.17 25.75 92 100 35 Humulene 17.69 27.12 27.77 100 44 9-decenoic acid, ethyl ester 18.35 1-Decanol 20.03 Acetic acid, 2-phenylethyl ester 20.96 21.42 22.05 100 60 43 Nonanoic acid, ethyl ester 23.02 Dodecanoic acid, ethyl ester 21.66 30.14 30.64 33 100 Phenylethyl alcohol 22.99 17.21 17.94 100 47 56 1-Undecanol 24.24 Octanoic acid 25.95 18.93 19.70 100 19 Decanoic acid 29.85 25.09 Acetic acid, decyl ester 26.07 Octanoic acid, 3-methylbutyl ester 27.05 Dodecanoic acid, 1-methylethyl ester 31.35 (30) 30 m long; (60) 60 m long; P polydimethylsiloxane; D divinylbenzene; C carboxen bath, as the ultrasonic bath also removes volatiles. Filtration is more suitable for carbon dioxide removal. Filter paper of type 388 is the most suitable for volatiles with lower molecular weight. It is generally suitable for compounds with low boiling point. Type 390 is preferable for volatiles with higher boiling point. In the first group of volatiles, octanoic acid ethyl ester is a compound with the highest boiling point. Reportedly, a good way to speed up the extraction process is to use stirring (Silva et al. 2008). However, stirring is not suitable for short-time extractions because the volatiles in the sample are not equilibrated with the gas phase above the sample. It causes too low repeatability (Table 1). Optimisation of gas chromatography conditions Choice of detector. The optimisation started by selection of the best available detector for the given type of analytes: MS and FID were compared. Although a flame ionisation detector used by Tian (2010) 246

Czech J. Food Sci. Vol. 32, 2014, No. 3: 241 248 60E+6 50E+6 40E+6 30E+6 20E+6 10E+6 000E+0 0 20 40 60 80 100 120 Fiber exposure time (min) 1-Butanol, 3-methyl-, acetate Hexanoic acid, ethyl ester Phenylethyl alcohol Octanoic acid, ethyl ester Acetic acid, 2-phenylethyl ester 9-Decenoic acid, ethyl ester Decanoic acid, ethyl ester Dodecanoic acid, ethyl ester Figure 6. The effect of adsorption time on the extraction efficiency of PDMS fibre ensures symmetrical peaks, a mass spectrometric detector was more suitable, because 43 volatile compounds were determined by GC-MS above the limit of quantification. The flame ionisation detector was able to quantify only 26 analytes. Using the mass spectra for the identification of analytes is another advantage of GC-MS. Choice of temperature programme. The temperature programme with the slowest temperature increase proved to be the most suitable for the determination of volatile compounds in beer. On the other hand, sufficient separation of basic volatile components was ensured also with the fastest increase of temperature at a much shorter time of analysis. Choice of chromatographic column. Several stationary phase sorbents were tested during the research. Table 2 shows that DB5 column of 60 m in length and SPME fibre with combination of sorbents are the most suitable, because the highest amount of substances of interest was identified using these sorbents. The longest temperature programme was used for this research. These results are in good accordance with data given in other papers (Cajka et al. 2010). Conclusion SPME is the most efficient sample preparation method for determination of volatiles in beer. The extraction efficiency of SPME is increased by salt addition, sample volume increase and proper temperature selection. The use of sonication for CO 2 removal decreases the recovery of volatile analytes. The use of filter paper is more favourable. The use of a stirrer causes worse reproducibility. GC analysis was performed with MS detector and DB5 column to obtain maximum sensitivity for the highest number of compounds. Volatiles in beer have different boiling points and molecular weights. Thus, different conditions according to individual analyte properties are preferable to improve the determination of these analytes, especially if contained in trace quantities. This way the detection limits can be shifted to levels that enable identification and quantitative determination of volatiles which are contained in trace quantities in the sample, but due to the low threshold of sensory perception are important for the quality of the product and are the main point of interest. References Coghe S., Martens E., D Hollander H., Dirinck P.J., Delvaux R. (2004): Sensory and instrumental flavour analysis of wort brewed with dark specialty malts. Journal of the Institute of Brewing, 110: 94 103. Cramer A.C.J., Mattinson D.S., Fellman J.K., Baik B.- K. (2005): Analysis of volatile compounds from various types of barley cultivars. Journal of Agricultural and Food Chemistry, 19: 7526 7531. Cajka T., Riddellova K., Tomaniova M., Hajslova J. (2010): Recognition of beer brand based on multivariate analysis of volatile fingerprint. Journal of Chromatography A, 1217: 4195 4203. Jelen H.H., Wlazly K., Wasowicz E., Kaminski E. (1998): Solid-phase microextraction for the analysis of some alcohols and esters in beer: comparison with static headspace method. Journal of Agricultural and Food Chemistry, 46: 1469 1473. Kolb B. (1999): Headspace sampling gas analysis by gas chromatography. Journal of Chromatography A, 842: 163 205. Kovačevič M., Kač M. (2001): Solid-phase microextraction of hop volatiles: Potential use for determination and 247

Vol. 32, 2014, No. 3: 241 248 Czech J. Food Sci. verification of hop varieties. Journal of Chromatography A, 918: 159 167. Lermusieau G., Bulens M., Collin C. (2011): Use of GColfactometry to identify the hop aromatic compounds in beer. Journal of Agricultural and Food Chemistry, 49: 3867 3874. Pawliszyn J. (2000): Applications of solid-phase microextraction in food analysis. Journal of Chromatography A, 880: 35 62. Pinho O., Ferreira I.M.P.L.V.O., Santos L.H.M.L.M. (2006): Method optimization by solid-phase microextraction in combination with gas chromatography with mass spectrometry for analysis of beer volatile fraction. Journal of Chromatography A, 1121: 145 153. Rodrigues J.A., Barros A.S., Carvalho B., Brandao T., Gil A.M., Ferreire A.C.S. (2011): Evaluation of beer deterioration by gas chromatography-mass spectrometry/ multivariate analysis: A rapid tool for assessing beer composition. Journal of Chromatography A, 1218: 990 996. Silva G.A., Augusto F., Poppi R.J. (2008): Exploratory analysis of the volatile profile of beers by HS SPME GC. Food Chemistry, 111: 1057 1063. Štěrba K., Dostálek P., Karabín M. (2011): Moderní postupy využívané při přípravě vzorků pro stanovení alkoholů, esterů a kyselin v pivu. Chemické listy, 105: 603 610. Tian J. (2010): Determination of several flavours in beer with headspace sampling gas chromatography. Food Chemistry, 123: 1318 1321. Wardecki, W., Sowiński, P., Curylo, J. (2003): Evaluation of headspace SPME for the analysis of volatile carbonyl compound in spirits and alcoholic beverages. Journal of Chromatography A, 984: 89 96. Received for publication December 17, 2012 Accepted after corrections July 4, 2013 Corresponding author: Prof. RNDr. Bořivoj Klejdus, Ph.D., Mendlova univerzita v Brně, Agronomická fakulta, Ústav chemie a biochemie, Zemědělská 1, 613 00, Brno, Česká republika; E-mail: klejdusb@seznam.cz 248