Clinical Histology Procedure histo13.01 Automated Immunohistochemical Staining Utilizing the Bond III Instrument



Similar documents
Clinical Histology Procedure Histo03.01 Automated Immunohistochemical Staining Utilizing the Ventana Benchmark Instrument

ab TripleStain IHC Kit: M&M&R on rodent tissue (DAB, DAB/Ni & AP/Red)

FULLY AUTOMATED PARALLEL DUAL STAINING DETECTION SYSTEM. ChromoPlex 1 Dual Detection for BOND

ab StayBlue/AP Plus Stain Kit Instructions for Use An immunohistochemical chromogen substrate for staining tissue sections

Hypoxyprobe -1 Plus Kit Kit contents:

Principles of Immunohistochemistry Queen s Laboratory For Molecular Pathology

How To Use Calretinin

Basic User Guide. Document Number D09665 Revision 01 July, For In Vitro Diagnostic Use

Clinical Histology Procedure histo Embedding Paraffin Processed Tissue

ArtisanLink Staining System is an automated special stains slide

Ep-CAM/Epithelial Specific Antigen (MOC-31)

Product Datasheet and Instructions for Use

TFE3 (MRQ-37) Rabbit Monoclonal Antibody PRODUCT AVAILABILITY SYMBOL DEFINITIONS INTENDED USE PRINCIPLES AND PROCEDURES SUMMARY AND EXPLANATION

Dot Blot Analysis. Teacher s Guidebook. (Cat. # BE 502) think proteins! think G-Biosciences

DISCOVERY. through color. A Guide to Multiple Antigen Labeling VECTOR LABORATORIES

LAB 14 ENZYME LINKED IMMUNOSORBENT ASSAY (ELISA)

IHC Service Center. Department of Medicine

Human Free Testosterone(F-TESTO) ELISA Kit

ECL Western Blotting Substrate INSTRUCTIONS FOR USE OF PRODUCTS W1001 AND W1015.

Principles And Procedures

The Value of Thyroid Transcription Factor-1 in Cytologic Preparations as a Marker for Metastatic Adenocarcinoma of Lung Origin

Checking the Package Contents. Installing the Printer Software. Connecting. Unpacking the. the Printer. Printer. Attaching

2. Cut 6 sheets of Whatman 3MM paper and 1 sheet of blotting membrane to the size of the gel, or slightly smaller.

Danish Keyboard Label Instructions and Specifications

PA500II Enterprise Mobile Computer

CONTROL: For staining fungus; use a known positive such as those used for the GMS. Use skin, aorta or normal liver for positive PAS staining.

Mouse Creatine Kinase MB isoenzyme (CKMB) ELISA

BenchPro 4100 Card Processing Station

510(k) SUBSTANTIAL EQUIVALENCE DETERMINATION DECISION SUMMARY

INSTRUCTION Probemaker

IHC-PARAFFIN PROTOCOL (IHC-P)

IgM ELISA. For the quantitative determination of IgM in human serum and plasma. For Research Use Only. Not For Use In Diagnostic Procedures.

Introduction Configuring Your HP Mouse Batteries Replacing the Batteries Mouse Sensor Technology Navigating the HP Mouse Control Center

Snap 9 Professional s Scanning Module

PROTOCOL. Immunocytochemistry (ICC) MATERIALS AND EQUIPMENT REQUIRED

Determining the Quantity of Iron in a Vitamin Tablet. Evaluation copy

STANDARD OPERATING PROCEDURE

Outline. 1. Experiment. 2. Sample analysis and storage. 3. Image analysis and presenting data. 4. Probemaker

Mouse IgM ELISA. Cat. No. KT-407 K-ASSAY. For the quantitative determination of IgM in mouse biological samples. For Research Use Only. 1 Rev.

College of Continuing Education Video Production Room

SMART Board 9 Software Tips and Tricks

Rat creatine kinase MM isoenzyme (CK-MM) ELISA Kit

Novocastra Liquid Mouse Monoclonal Antibody CD141 (Thrombomodulin)

How To Use A Brother Ql700

Appendix C. Vernier Tutorial

Microsoft Access 2010 handout

Fingerprint Identity User Manual for the Griaule Biometric Framework Rev 1.00

EDUCATION. HercepTest TM. Interpretation Manual Breast Cancer

RPCI 004 v.002 Staining Procedure For all Directly Conjugated Reagents (Whole Blood Method)

Working with SQL Server Integration Services

SDS-PAGE Protocol Mutated from the SDS-PAGE protocol written by the Lord of the Flies

Mouse Keyhole Limpet Hemocyanin antibody(igm) ELISA Kit

INF-USB2 and SI-USB Quick Start Guide

Dengue IgM ELISA. For the quantitative determination of IgM-class antibodies to Dengue Virus in serum.

CDC-Lipid Standardization Program. Laboratory Data Collection System (LDCS) Instruction Manual

OxySense Gen III Operations Manual

竞 争 性 分 析 Epitope Mapping 实 验 方 法

Protease Peptide Microarrays Ready-to-use microarrays for protease profiling

Rat Creatine Kinase MB isoenzyme,ck-mb ELISA Kit

Ep-CAM/Epithelial Specific Antigen (Ber-EP4)

Tissue Cross-Reactivity of QRX-111 with Human, Cynomolgus Monkey and Rat Tissues in Vitro

OPERATION MANUAL. MV-410RGB Layout Editor. Version 2.1- higher

Zetasizer Nano-ZS User Instructions

Parathyroid Hormone (PTH) (MRQ- 31)

Guide for usage of digital signatures in Microsoft Office Documents

How do I monitor the ink levels on my EPSON Stylus printer using Windows 2000 or XP?

Canine creatine kinase MB isoenzyme (CK-MB)ELISA Kit

hp deskjet 948c/940c/920c series learning about your printer... 1

Protein transfer from SDS-PAGE to nitrocellulose membrane using the Trans-Blot SD cell (Western).

Human Luteinizing Hormone (LH) Custom Kit

WESTERN BLOT DETECTION KIT Buffers and detection reagents for up to ten 10 x 10 cm 2 blots. Fluorescent detection via: Goat anti-mouse SureLight P3

Rat creatine kinase MM isoenzyme (CK-MM) ELISA Kit

WAMLocal. Wireless Asset Monitoring - Local Food Safety Software. Software Installation and User Guide BA/WAM-L-F

SMART Ink 1.5. Windows operating systems. Scan the following QR code to view the SMART Ink Help on your smart phone or other mobile device.

1. Open the battery compartment as shown in the image.

Mouse krebs von den lungen 6 (KL-6) ELISA

Microsoft PowerPoint 2010 Computer Jeopardy Tutorial

Leica CEREBRO Sample Tracking. Patient Safety. Enhanced Productivity. Complete Flexibility.

Compass Software for Peggy User Guide

WESTERN BLOTTING TIPS AND TROUBLESHOOTING GUIDE TROUBLESHOOTING GUIDE

How Does a Doctor Test for AIDS?

SA-9600 Surface Area Software Manual

Serology: Fluorescent antibody tests and other tests employing conjugated antibodies

How to operate the BD FACSCanto flow cytometer

How To Send An Encrypted In Outlook 2000 (For A Password Protected ) On A Pc Or Macintosh (For An Ipo) On Pc Or Ipo (For Pc Or For A Password Saf ) On An Iphone Or

Epinephrine/Norepinephrine ELISA Kit

Accounts Payable Invoice Entry Monroe County, WI

Advanced Presentation Features and Animation

Application Guide... 2

P3000 Printer Guide Rev A. January 2006

Simple Computer Backup

Installing EDS III or EDS IV Network Support for Microsoft Windows 95 or 98 Part Number Rev. D

Lab 02: Blood Cytology (20 points)

Mouse GLP-2 ELISA. For quantitative determination of mouse GLP-2 in serum or plasma samples.

WHO Prequalification of Diagnostics Programme PUBLIC REPORT. Product: Genscreen ULTRA HIV Ag-Ab Number: PQDx Abstract

Evaluation copy. Enzyme Action: Testing Catalase Activity (Method 1 O 2 Gas Sensor) Computer 2

Product name Company Cat # PowerPac Basic Power supply Bio Rad Mini Protean electrophoresis system Mini trans blot cell Bio Rad

Coating and Extraction of Honeycomb Denuders

Western BLoT Immuno Booster

Microinvest Warehouse Pro Light Restaurant is designed to work in tandem with Microinvest Warehouse Pro which provides all back office functions.

Transcription:

Clinical Histology Procedure histo13.01 Automated Immunohistochemical Staining Utilizing the Bond III Instrument Final Approval: October 2010 Effective: October 2010 Next Review Date: February 2013 List all stakeholder(s) and dates of approval: Stakeholder Name(s): Shelly Siegel, HT Date: 9.21.10 Reviewed Revised Stakeholder Name(s): Mark Magilner, MD Date: 10/4/2010 Reviewed Revised Stakeholder Name(s): Shelly Siegel Date: 10/11/11 Reviewed Revised Stakeholder Name(s): Shelly Siegel Date: 2/14/12 Reviewed Revised Stakeholder Name(s): Date: Reviewed Revised Describe briefly the most recent revision made to this policy, procedure or protocol & why: New Procedure Purpose/Policy Statement: The demonstration of antigens in tissue and cells by immunostaining is a process involving first, the binding of an antibody to an antigen of interest and second visualization of the bound antibody by a biotin-free, polymeric horseradish peroxidase (HRP). The Bond Polymer Refine Detection system detects tissue- bound mouse and rabbit IgG and some mouse IgM primary antibodies. The detection kit is intended for staining sections of formalin-fixed, paraffin-embedded tissue on the Bond automated system. It utilizes a novel controlled polymerization technology to prepare polymeric HRP linker antibody and avoids the use of streptavidin and biotin. Therefore, eliminates non-specific staining as a result of endogenous biotin. The Bond DAB enhancer precipitates as a copper salt at the reaction site producing a darker brown staining deposit. Bond Polymer Refine Detection Catalog # DS9800 200-300 tests works as follows: The specimen is incubated with hydrogen peroxide to quench endogenous peroxidase activity A post primary antibody solution enhances penetration of the subsequent polymer reagent A poly-hrp anti-mouse/rabbit IgG reagent localizes the primary antibody The substrate chromogen, 3.3 - diaminobenzidine (DAB), visualizes the complex with a brown precipitate Hematoxylin counterstaining allows the visualization of cell nuclei Bond Polymer Refine Red Detection a biotin-free, polymeric alkaline phosphatase (AP)-linker antibody conjugate system. Catalog # DS9390 100 tests works as follows: A user-supplied specific primary antibody is applied Post primary IgG linker reagent localizes mouse antibodies Poly-AP IgG reagent localizes rabbit antibodies The substrate chromogen, Fast Red, visualizes the complex with a red precipitate Hematoxylin counterstaining allows the visualization of cell nuclei Page 1 of 5

Slide barcode labels operate the instruments automated, sequential dispensing of appropriate reagent and antibody dilutions. Definitions: n/a STEPS / KEY POINTS SPECIMEN: Paraffin sections of 3-micron or 4-micron thickness are collected from an 40-45 o C flotation bath containing deionized water and mounted on 25 x 75 mm positive (+) charged slides or cytological samples prepared by smear or Cytospin technique fixed in 95% alcohol. MATERIALS, REAGENTS: Bond system ancillary hardware/consumables: Bond Universal Slide Labels/ Printing Ribbon- Slide Labeller type TLP 3842 Handheld ID scanner Bulk reagent/waste containers Covertiles, slide trays, reagent trays Ancillary Products: Reagents CAUTION: STRONG OXIDIZER, IRRITANT. Wear appropriate protective equipment. Bond wash solution 10X- AR9590 Bond Epitope Retrieval Solution 1- AR9961 Bond Epitope Retrieval Solution 2- AR 9640 Bond dewax solution- AR9222 Primary Antibody Diluent- AR9352 CAUTION: IRRITANT. Wear appropriate protective equipment. Bond Ready-to-use antibody dispenser, open containers Anti-Fluorescein antibody- AR0222 Aspirating Probe Cleaning System- CS9100 Enzyme Pretreatment Kit- AR9551 DAB Enhancer- AR9432 INSTRUMENTATION OR EQUIPMENT: Bond- III instrument. PROCEDURE: 1. From a tissue flotation bath of deionized H 2 O, retrieve the cut paraffin section of the patient case on the bottom of the microslide which contains the known positive tissue or multi-tissue controls on the top of the slide for the requested antibody. Only in circumstances where the patient tissue sample is larger than the provided slide space, use the slide as a control only and place the patient tissue sample on a 25 x 75 mm positively (+) charged microslide. 2. Using a permanent marking pen, label slide with: antibody name procedure date accession number (at bottom edge). 3. Routinely dry slides at 60 O C in convection oven for 30 min. 4. Remove from IHC refrigerator the reagent tray(s) containing any and all detection kits and primary antibody containers required for protocols being performed. Prepare for operation by uncapping and loading tray on the instrument. 5. Allow antibodies/reagents/ to reach room temperature prior to staining. 6. Preliminary check before start up: Page 2 of 5 Antibody Date 2B M06-12345 (+) PATIENT + +

Ensure the processing module is clean and up to date by checking the Cleaning and Maintenance Schedule. Daily prerun tasks are checking the bulk waste containers are empty and the bulk reagents have sufficient/correct reagent in them. Check wash blocks and mixing station- clean or replace. Check that the slide labeler has enough supply of labels. Turn ON BOND III instrument at the operational PC CPU and at also at the red switch located facing the right side of the instrument. Sign on using: name- bonduser/ password- bond12345 Check the Status screen to ensure there are no processing module notifications. Rectify before attempting to run any slides. 7. Prepare slide barcode labels. 8. From the PC desktop menu, select the BOND icon. WINDOW Home screen SELECT from the function bar Slide setup icon. CLICK Add case. CLICK in the Case ID field and type the accession # or what how you want to label the slide. OK to close the Add case dialog. Select the case ID in the case list on the left of the screen. CLICK Add slide tab. CLICK on the arrow down from the Marker tab to select antibody. CLICK Add slide. Repeat from the Marker list per antibody ordered. After all slides have been added, click Close to close the Add slide dialog. Review the details in the slide list found on the right side of the screen. If you need to change details for a slide, right-click on the slide. Select Slide properties from the submenu then click OK. CLICK Print Labels from the Slide setup screen. CLICK All slide labels not yet printed then CLICK Print. 9. Apply each printed BOND bar-code label to its corresponding slide. Apply the label over the painted section of the slide, without extension over any slide edge. 10. Install an individual slide in an empty position in the Slide tray, with the label end on the opposite side of the #. Place the slide down so it sits in the recessed position in the tray. 11. Hold a covertile by the head, and position it over the slide with the key in the neck aligned with the recess in the tray. Lay the covertile on the side, fitting the key into the slot. Tally the covertile with a statmark pen. Toss the covertile when the tally reaches 10 or when the covertile is scratched, worn or cracked. 12. Lift the tray and rest the end on the entrance to an empty slide staining assembly. Position the right runner of the tray in the guides and gently slide the tray as far as it will go into the module. The tray should slide in easily and audibly click when it is in place. 13. Press the Load/Unload button on the front panel beneath the loaded tray. 14. It there are reagents are not available, the software displays an attention icon below the slide list. Right-click on the icon for more information. 15. The slides are now ready for a staining run. The progress bar will be in the staining phase and the run status will be Slides ready. CLICK the play/to go icon to begin immediately or delay by right-clicking on the slide tray. The progress bar will switch to the processing phase and the run status will be Proc (OK). 16. When finished the processing module tab icon flashes green. 17. Following completion of the instrument staining program: Press the Load/Unload button and remove slide trays Remove the covertiles by lifting the end off the slide. Do NOT SLIDE across the surface of the slide, you may damage the tissue. Place covertiles in 70% alcohol container or toss at 10 uses. Place slides in rack and remove liquid coverslip by manually dipping in 3 changes of 100% alcohol and 2 changes of Xylene. Coverlip on automated tissue-tek and let slide dry a few minutes before distributing to the pathologists. Page 3 of 5

18. Print from the Sundial icon. Brief Slide history, change to current day and beginning of run to the end. Print to the HP deskjet printer. Use the Brief Slide history sheet to quality control check all slides before distributing to the pathologists. Any comments/staining issues need to be noted on the sheet and communicated to the pathologist for immediate repeats if necessary. CALIBRATION: Annual calibration is performed on each micropipette by a professional service. QUALITY CONTROL: 1. Positive result on negative control may be an indicator of endogenous biotin in certain types of tissue sample (brain, breast, kidney, or most frequently liver) in some patient cases.the resulting negative result on the negative control validates the prior staining reaction as endogenous biotin. 2. Each time the procedure is performed a known positively reactive tissue for the specified antigen shall be simultaneously processed with the patient tissue. 3. For each patient block on which IHC is performed, a corresponding patient NEGATIVE control slide shall be simultaneously stained with the patient slide(s), excluding the application of the Primary Antibody. NEGATIVE control receives most harsh treatment of all protocols performed on the case. 4. Ventana PATHWAY HER-2 4 in 1 Control Slide validates staining quality, per each protocol run (for HER2). 5. The ph of Reaction Buffer is measured and documented on the ph Buffer form each time a working solution is prepared. 6. Each time a five-gallon carboy of bulk ancillary reagent is emptied, it shall be decontaminated then rinsed thoroughly with DH2O, wiped dry and/or drained. 7. Routine instrument maintenance is performed daily, monthly, and quarterly by a staff Histologist and documented. 8. New lots of antibody reagents are compared to the previous lot using an appropriate panel of control tissue. Documentation of validated new antibodies are maintained on the Antibody Quality Control Sheet. Control tissue blocks are validated prior to patient testing. It is documented and maintained on the Tissue Block Quality Control Sheet. The director of Pathology validates all antibodies and tissue control blocks before patient use. 9. P/M is performed annually by a Bond representative under a purchased manufacturer service/maintenance contract. PROFICIENCY TESTING: CAP Proficiency Survey / Immunohistochemistry, CAP HistoQip, HER2 and ER/PR. RESULTS: 1. Positive results will be demonstrated with variations of colored staining based upon use of specific detection kit systems; negative results will be demonstrated by the presence of counterstain only. 2. Positive result on negative control may be an indicator of endogenous biotin in certain types of tissue sample (brain, breast, kidney, or most frequently liver) in some patient cases. See QUALITY CONTROL. PROCEDURE NOTES: In the event of an equipment downtime, arrangements have been made with Northwest Pathology in Eugene, OR for testing. Equipment/Supplies (If Applicable): Form Name & Number or Attachment Name (If Applicable): Histo13 Author Position: Lead Histologist Review/Revision Authority (Position Not Individual Name): Lead Histologist Expert Consultant Position/s (Not Individual Name/s): Page 4 of 5

References (Required for Clinical Documents): MANUFACTURER'S PACKAGING BROCHURE/INSERT: Leica Bond User Manual Rev H01 Leica Biosystems Melbourne 2009 Is there a Regulatory Requirement? Yes If yes, insert requirement information here: No Review History (No Changes): Revision History (Note changes in area under header): Computer Search Words: Policy, Procedure or Protocol Cross Reference Information: Page 5 of 5