BR I Blood Bank Refrigerators



Similar documents
S G G S G G S G G S G G. FR / MF range. Deep Freezers & Plasma Storage Freezers

LABORATORY / MEDICINE / PHARMACEUTICAL REFRIGERATORS

Transport Boxes (active & passive systems)

MT I Transport Boxes (Active & Passive)

Freezers - Ultrafreezers. Platilab & Irilab Series

BIOMEDICAL REFRIGERATORS

Material test chamber with mechanical convection

Refrigerators - Freezers. Ekofrigolab & Ekobasic Series

IC+ NEW inverter compressor technology delivers energy saving, high performance cooling

CRAC Precision climate control units for data centres

Incubator with mechanical convection

Blood Bank Refrigerators according to DIN Blood Plasma Freezers according to DIN 58375

VTS³ and VCS³ Stress Screening Systems. More Power for Maximum Quality Assurance

Vacuum drying oven for non-flammable solvents

OT 40L / 90L. Laboratory Steam Sterilizers

Thermostatic Equipment

Operating ambient temperature range: 5ºC to 50ºC Storage temperature range: -30ºC to 70ºC

Heating oven with mechanical convection

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Heating oven with mechanical control

HERZ-Thermal Actuators

Incubators, cooled incubators, drying ovens, sterilizers, climatic chambers

Professional Kitchens

08 FRIDGES & FREEZERS

Refrigeration Compressed Air Dryer Buran Ultrapulse

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

Climate chamber with illumination

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

Electronic Control Devices The European Product Catalogue 2007

ECOCIAT. Domestic hot water heat recovery unit

GSM HOME SECURITY SYSTEM

Silicone oil is as the medium and the drying effect is uniform. The Temperature error is less than or equal 1.

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

PowerGem Pro Uninterruptible Power Supply

THE OPTIMAL SOLUTION FOR SMALL AND MEDIUM DATA CENTER

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

Computer Controlled Capacity Control Methods in Refrigeration, with SCADA and PID Control THARA2C/1

STERILIZERS, LABORATORY DRYING OVENS

Climate Test Chamber. System Weiss. Type WK3-2000/40

Electronic Control Devices The European Product Catalogue 2007

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

Intelligent chart recorder for compressed air and gases. Measurement - control - indication - alarm - recording - evaluation

site monitoring Kit Site Monitoring Kit User Manual we prove it.

RPV - RP - RA air handling units

USER MANUAL V5.0 ST100

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

Rotary screw compressors kw 5,5 7, , bar MODULO

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

Process Alarm Solutions

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

-86 C Freezer Accessories. New Brunswick Freezer Accessories. A wide selection of racks, monitoring systems and more!

IPThermo206G. Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network

NIKY and NIKY S. UPS SINGLE-PHASE from 600 to 3000 VA GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Product Information Fire alarm panel 8000 C

Standard Features: Options:

Computer Controlled Vortex Tube Refrigerator Unit, with SCADA TPVC

Thyristor-controlled power supplies and battery chargers

MANUAL PC1000R

86 C Freezer Accessories. More Choices. Choose from a Wide Selection of Racks, Monitoring Systems and Other New Brunswick Freezer Accessories

KR25i HIGH SPEED, HIGH CAPACITY REFRIGERATED CENTRIFUGE AUTO-LOCK. CQCS Traceability System VIDEOset Display!

Gree Solar Hybrid Hi Wall Inverter Air Conditioner

WAECO COOLMATIC 2.8 CUBIC FEET 12/24 VOLTS DC & 110 / 220 VOLTS AC BUILT-IN REFRIGERATOR-FREEZER WITH FLUSH MOUNT FRAME

Clinic Washer-Disinfectors. Washer-Disinfector Line

Installation Instructions. Thermo Call TC3

RECALDO CLASSICO The reliable induction trolley for Cook & Chill, Cook & Serve and Cook & Freeze

AUROLEX. Plug and Play Monitoring. The best ways to achieve a cleaner, safer environment

/ Our accessories complement all PV systems, simplify installation and ensure that the system meets the required safety standards.

LyoBeta. R+D Freeze-Dryers

CW-5000/ 5200,1'8675,$/ &+,//(5 86(5 0$18$/

CoolTeg Plus Chilled Water (CW) version: AC-TCW

Thermo Scientific Heratherm Microbiological Incubators. Safe, easy and efficient

1 Safety instructions. 2 Device components. Facility Pilot Server. Art. No. : FAPV-SERVER-REG Art. No. : FAPVSERVERREGGB. Operating instructions

Hand-held thermometer Model CTH7000

Sterilizers with extra class

Digital input modules

is then retained absolutely without interruption.

S100. GSM House Alarm System.

york air-conditioning products Residential & VRF News 2015

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

Drayton Digistat +2RF/+3RF

SERVICE MANUAL REFRIGERATION

Digital display DA 48

How To Use A Ds340 (Dsp)

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

High Security Heavy Duty Shredders VZ Perfect shredding and high performance in DIN security levels 4 and 5

INSTRUCTION MANUAL CIRRO MK 3/TYPE 2 MIST GENERATOR

FOXAIR 60/50 ALL MODELS

Vertical and Benchtop Autoclaves for Life Sciences. Laboratory Line

Technical data. Danfoss DHP-A

OZS Web server. For LPB/BSB plants

How To Buy An Fujitsu Primergy Bx400 S1 Blade Server

ALARMLINE ANALOGUE Linear Heat Detection System

Meaco 30L and Meaco 40L dehumidifier instruction manual

deli makes business more delicious! impulse coolers

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1

LLB-OCMFM 2000 PORTABLE DOPPLER AREA-VELOCITY FLOWMETER

Transcription:

Technology for Life Medical SYSTEMS Technology for Life BR I Blood Bank Refrigerators +4 C 292.9707.50 08/2013 BIOMEDICAL REFRIGERATION Innovative and reliable refrigeration solutions compression Refrigerators, Freezers and Ice Liners Absorption Refrigerators and Freezers Vaccine Transport Boxes Legally safe storage of blood at +4 C In compliance with international s and directives www.dometic.lu

+ 4 C I BR BR range BR 110 GG BR 250 G / GG BR 410 G / GG BR 490 G / GG BR 750 G / GG Refrigerators for the legally safe storage of blood bags / erythrocyte concentrates at +4 C (according to DIN 58371, ÖNORM K 2030 & Medical Device 93/42/EEC) The interior temperature of the blood refrigerators is monitored via an autonomous control sensor and adjusted to +4 C. This ensures that the product temperature of the stored preparations is kept at +4 C ± 1.5 C. The models of the BR range feature a natural defrosting system that does not affect the product temperature of the stored preparations during defrosting. BR models are equipped with a glass door for quick checks and pre-selection of the refrigerator s content. The transparent front panel of the ST-Drawers, which are part of the equipement of the BR models, minimize cold losses when the door is opened. Models BR 250 G 750 G are available as 220 V and 115 V version. safety GOLD GREEN The BR range comprises 5 Blood Refrigerators that are built in compliance with the requirements of : din 58371 (Germany, Blutkonserven-Kühlgeräte / Blood Refrigerators) ÖNORM K 2030 (Austria, Blutkonserven- Kühlschränke / Blood Refrigerators) european Medical Device Directive 93/42/EEC In conformity with: as 3864 (Australia, Medical refrigeration equipment for the storage of blood & blood products ) BS 4376-1: 1991 (UK, Electrically operated blood storage refrigerators. Specifications for closed reach-in types ) european Directive Guide to preparation, use and quality assurance of blood components 02 03 Subject to change without prior notice. Some of the accessories shown in the pictures are optional. The approximate figures are based on the number of bags that are really to be stored and on the different bag manufacturers specifications available on the market, on the actual bag sizes as well as on the individual user s practice of loading.

Blood Bank Refrigerators I + 4 C BR 110 GG BR 250 G / GG Gross volume (l) 106 Net volume (l) 92 BR 110 GG Gross volume (l) 246 Net volume (l) 167 BR 250 G BR 250 GG 54 at 450 ml each 72 at 350 ml each 120 at 450 ml each 160 at 350 ml each (Kwh/24h) 0.75 (Kwh/24h) 1.50 0.95 (37% less) Noise level (db(a)) 41 Noise level (db(a)) 49 42 BR 410 G / GG BR 490 G / GG BR 750 G / GG BR 410 G BR 410 GG BR 490 G BR 490 GG BR 750 G BR 750 GG Gross volume (l) 408 Gross volume (l) 489 Gross volume (l) 746 Net volume (l) 319 Net volume (l) 395 Net volume (l) 620 240 at 450 ml each 320 at 350 ml each 300 at 450 ml each 400 at 350 ml each 450 at 450 ml each 550 at 350 ml each (Kwh/24h) 1.70 1.00 (41% less) (Kwh/24h) 1.90 1.10 (42% less) (Kwh/24h) 2.00 1.20 (40% less) Noise level (db(a)) 51 42 Noise level (db(a)) 51 42 Noise level (db(a)) 51 42 Technology for Life

+ 4 C I BR The Safety Standards developed by define certain significant technical features of a product. These ensure the safe storage of the preparations as well as the trend-setting safety of the user. safety GOLD The Gold Safety Standard efficiently complements the safety requirements of the Silver Safety Standard and therefore exceeds even the official s. Gold models are denominated with a G. The new green models (denominated with a G ) convince by their technical optimizations in terms of economy and enviromental protection. Characteristic features are : use of natural gases as refrigerants 40-60% less energy consumption up to 40% less power needed over 80% less heat ejection In addition, the new green models stand out because of improved hold over times thanks to optimized door insulation and drastically reduced noise level for more workplace convenience. MODEL BR 110 GG BR 250 G / GG BR 410 G / GG BR 490 G / GG BR 750 G / GG DIN 58371 & ÖNORM K 2030 ( Blood Refrigerators ) Glass door with triple insulating GMP Clean Room Class A / ISO 5 (ISO EN 14644-1) Electronic Key-operated power switch (power ON/OFF) Safety door lock Digital temperature indicator (display: 0.1 digits) Controlled fan cooling system for constant temperature and even temperature distribution across the entire refrigerating chamber. Automatic fan switch-off when front door opens Self-contained alarm system with integrated battery takes over the alarm function and temperature value measurements in case of power failure for at least 48 hours Acoustic/visual alarm signal in case of temperature alarm and power failure All relevant data of temperature alarm and power failure alarm are stored in the alarm history. Such as date and time of start and end, min. max and average temperature Alarm function test: simulation of a temperature rise or drop in order to test the alarm system functionality Control via self-diagnostic system Safety thermostat prevents dropping of the cold storage products temperature below +2 C LED lighting Door opening alarm Remote transmission alarm signal (via potential-free contact) in case of temperature alarm (change-over contact) Remote transmission alarm signal (via potential-free contact) in case of power failure (change-over contact) Automatic closing of the front door below a door opening angle of 90 Interior made from stainless steel Climate class (ambient temperature range) SN/T (+10 C to +43 C) Smooth castors with stabilizers for optimum flexibility of movement RS 485 interface for the display of all operating and control functions (hardware and software settings) via DMN monitoring software on a peripheral device (computer) DMN software package DCU Communication Unit optional not available 0499 DIN 58371 ÖNORM K 2030 ISO EN 13485 04 05 Subject to change without prior notice. Some of the accessories shown in the pictures are optional. The approximate figures are based on the number of bags that are really to be stored and on the different bag manufacturers specifications available on the market, on the actual bag sizes as well as on the individual user s practice of loading.

Electronic The new and innovative Electronic (operation and control panel) assures thanks to its password protected settings menu optimum protection for your stored preparations. The menu structure of the modern and user-friendly graphic display offers a simple and intuitive utilization. LED Alarm Navigation buttons Settings menu Extra menu Power switch, key-operation O = OFF / I = ON LED Power on Back button Menu button The new Electronic also offers: a wide range of adjustment and diagnostic facilities as well as additional protection / warning operations (via external alarm operations, histories and individual display signals). an optional PT100 sensor inlet to show the sensor s temperature data on the display as well as forwarding and further processing via a 4... 20 ma outlet. an optional 4...20 ma outlet to transmit temperature data of a sensor connected to the electronic. connection facilities for additional (optional) temperature sensors. dmn ( Monitoring Network) and the (optional) DCU ( Communication Unit) allows illustration of texts on the product s display. The refrigeration system of the BR models is optimally adjusted with regard to power consumption, waste heat and noise development. The autonomous display sensor located in a reference body defined by s shows the temperature changes on the operation and control panel, in analogy to the temperature within the preparation to be cooled. This ensures that the entire product still has the allowed temperature (+4 C ± 2 C) if an alarm is triggered. The (subsequent) control of the product temperature and the documentation of the temperature changes can be carried out via an optional temperature recorder (in form of a circular chart recorder) or via the optional DCU via the Monitoring & Visualization software DMN. Reference body for display sensor with reference fluid 100 ml DOW corning 200-5CST (Silicon Oil). Simulates the temperature inertia of the stored product. Technology for Life

Technical Data BR 110 GG BR 250 G / GG safety GOLD GREEN Gross volume 106 l 246 l Net volume 92 l 167 l : blood bags at 450 ml each / approx. 54 120 : blood bags at 350 ml each / approx. 72 160 External dimensions (H x W x D) 820 x 560 x 580 mm 1305 x 850 x 785 mm Inner dimensions (H x W x D) 495 x 470 x 455 mm 655 x 680 x 552 mm Net weight with equipment 76 kg 145/142 kg Set temperature (preset - not changeable, l by DIN 58371) +4 C +4 C Temperature cold alarm limit (preset not changeable, l by DIN 58371) +2 C +2 C Temperature warm alarm limit (preset not changeable, l by DIN 58371) +6 C +6 C Control sensor PT1000 2-WIRE 1/3DIN CL.B PT1000 2-WIRE 1/3DIN CL.B Precision (from 80 C to +180 C) ± 0,2 C ± 0,2 C Display sensor PT1000 2-WIRE 1/3DIN CL.B PT1000 2-WIRE 1/3DIN CL.B Precision (from 80 C to +180 C) in reference body with reference fluid 100 ml DOW corning 200-5CST (Silicon Oil) ± 0,2 C ± 0,2 C Frequency 220-240V 50 Hz 50/60 Hz 50 Hz Power 220-240V 80 W 215 W 120 W 220-240V 0.75 kwh/24h 1.50 kwh/24h 0.95 kwh/24h Heat emission 220-240V 18 kcal/h 31 kcal/h 22 kcal/h Compressor running time 220-240V 26% 18% 21% Noise level at 1m height & 1m distance 220-240V 41 db(a) 49 db(a) 42 db(a) Accu data / function time of the control panel when power failure 12V -7 AH / 48 hours 12V -7 AH / 48 hours Climate class (ambient temperature range) SN / T (+10 C to +43 C) SN / T (+10 C to +43 C) Relative humidity at ambient temperature 75% 75% Defrosting technique natural natural Refrigerant type R600a R134a R600a Door insulation 65 mm, with triple insulating 100 mm, with triple insulating Casing insulation (polyurethane) 25 mm PU + 20 mm VIP 85 95 mm Hold over time (from +4 C to +10 C) 102 min 192 min Safety class I I European Medical Device Directive 93 / 42 / EEC 93 / 42 / EEC GMP - clean room classification A / ISO 5 A / ISO 5 Material inner body Stainless steel (V2A 1.4301) Stainless steel (V2A 1.4301) Material outer casing & door Material (Drawers) Stainless steel (V2A 1.4301) Stainless steel (V2A 1.4301) Material (Wire Shelves) Wire DIN 172-2, PA11 coated Wire DIN 172-2, PA11 coated Material (N-Rack) Polycarbonate, transparent Polycarbonate, transparent Color outer casing White (similar RAL 9010) White (similar RAL 9010) Color contrasts Blue (similar RAL 5002) Blue (similar RAL 5002) Interior Equipment & Options (Concerning further information on accessories please see our separate leaflet Racking & Storage Systems ) ST-Drawers 2 ST-Drawers with Front Cover 1 ST-Drawer with Front Cover incl. 5 N-Racks without Standard interior equipment Front Cover Wire shelves 1 incl. 5 N-Racks with Front Cover DCU LAN/WLAN RS 485 interface DMN Software package Ambient temperature sensor Potential-free contact in case of power failure Integrated inlet for external sensor (installed by customer) Display sensor in reference bottle with reference fluid Condenser filter Smooth castors with stabilizers for optimum flexibility of movement LED lighting Temperature recorder in form of a circular chart recorder / Measuring / recording range: -10 C to +20 C Integrated for 24h or 7 days Integrated for 24h or 7 days External water cooling Door hinge right Door hinge left Wooden packaging for ocean transport / export / optional / not available All values were measured at +25 C ambient temperature and without load (with inertial mass). 06 07 Subject to change without prior notice. Some of the accessories shown in the pictures are optional. The approximate figures are based on the number of bags that are really to be stored and on the different bag manufacturers specifications available on the market, on the actual bag sizes as well as on the individual user s practice of loading.

BR 410 G / GG BR 490 G / GG BR 750 G / GG Equipment / Options (extract) 408 l 489 l 746 l 319 l 395 l 620 l 240 300 450 320 400 550 1735 x 850 x 785 mm 1950 x 850 x 785 mm 1990 x 910 x 985 mm 1085 x 680 x 552 mm 1300 x 680 x 552 mm 1352 x 730 x 760 mm 187/180 kg 209/203 kg 262/256 kg +4 C +4 C +4 C +2 C +2 C +2 C +6 C +6 C +6 C PT1000 2-WIRE 1/3DIN CL.B PT1000 2-WIRE 1/3DIN CL.B PT1000 2-WIRE 1/3DIN CL.B ± 0,2 C ± 0,2 C ± 0,2 C PT1000 2-WIRE 1/3DIN CL.B PT1000 2-WIRE 1/3DIN CL.B PT1000 2-WIRE 1/3DIN CL.B ± 0,2 C ± 0,2 C ± 0,2 C 50/60 Hz 50 Hz 50/60 Hz 50 Hz 50/60 Hz 50 Hz 240 W 120 W 265 W 120 W 280 W 120 W 1.70 kwh/24h 1.00 kwh/24h 1.90 kwh/24h 1.10 kwh/24h 2.00 kwh/24h 1.20 kwh/24h 43 kcal/h 24 kcal/h 48 kcal/h 27 kcal/h 58 kcal/h 29 kcal/h 21% 23% 23% 26% 24% 28% 51 db(a) 42 db(a) 51 db(a) 42 db(a) 51 db(a) 42 db(a) 12V -7 AH / 48 hours 12V -7 AH / 48 hours 12V -7 AH / 48 hours SN / T (+10 C to +43 C) SN / T (+10 C to +43 C) SN / T (+10 C to +43 C) 75% 75% 75% natural natural natural R134a R600a R134a R600a R134a R600a 100 mm, with triple insulating 100 mm, with triple insulating 85 mm, with triple insulating 85 95 mm 85 95 mm 90 mm 204 min 210 min 168 min I I I 93 / 42 / EEC 93 / 42 / EEC 93 / 42 / EEC A / ISO 5 A / ISO 5 A / ISO 5 Stainless steel (V2A 1.4301) Stainless steel (V2A 1.4301) Stainless steel (V2A 1.4301) Stainless steel (V2A 1.4301) Stainless steel (V2A 1.4301) Stainless steel (V2A 1.4301) Wire DIN 172-2, PA11 coated Wire DIN 172-2, PA11 coated Wire DIN 172-2, PA11 coated Polycarbonate, transparent Polycarbonate, transparent Polycarbonate, transparent White (similar RAL 9010) White (similar RAL 9010) White (similar RAL 9010) Blue (similar RAL 5002) Blue (similar RAL 5002) Blue (similar RAL 5002) Temperature recorder (in form of a circular chart recorder), integrated for models BR 110 GG 750 G / GG ST-Drawer with/without Front Cover, on telescopic runners with safety stop (partly or optional, for models BR 110 GG 750 G / GG) Wire Shelf 2 ST-Drawers with Front Cover incl. 5 N-Racks without Front Cover 2 incl. 5 N-Racks with Front Cover 3 ST-Drawers with Front Cover incl. 5 N-Racks without Front Cover 2 incl. 5 N-Racks with Front Cover 3 ST-Drawer with Front Cover incl. 5 S-Racks 2 incl. 5 S-Racks N-Racks with/without Front Cover can be equipped with Rilsan Separator ( optional, for models BR 250 G / GG 750 G / GG) Integrated for 24h or 7 days Integrated for 24h or 7 days Integrated for 24h or 7 days Remote temperature and power failure alarm Water cooling, external (ex factory) (optional, for BR model range) Technology for Life

Software DMN Monitoring Network Universal software for collection, long-term recording and visualization of temperature data. Complete activity list (password protected). integrated event and activity history of all appliance components. graphical visualisation of all temperature curves. Connection to existing or third-party appliances via network technology (LAN, WLAN, WAN). Simultaneous data monitoring and recording. Possibility for specific and individually configurable alarm forwardings, e. g. via email, SMS (with optional GSM module) or via DECT. Simple and intuitive utilization. Essential price advantage compared to a traditional circular chart recorder and its spare parts. Free of charge for all Gold & Silver ranges. DCU Communication Unit Hardware module that notes all operating conditions and passes them through to a central data base via local network, on which devices are connected. interface connection of appliances to an existing network. The DCU offers direct connection to the Ethernet, even wireless, to the serial BUS RS 485, as well as to the central building control system (4... 20 ma). Possibility of connection of actors (4... 20 ma out). Digital IN/OUT (customer-specific use of these connections is programmable). The integrated USB port allows stored data to be written to an external memory stick. Recording and storage of relevant data of the appliance. The DCU replaces the paper temperature recorder. The DCU works with all Gold electronics from 2000 on. All data are recorded and saved in the data base of the DMN and are available for analysis at any time. Real-time temperature output for third-party software. Your essential advantages: access to the data within your entire network via one central database. economy of time and money as regular changes of recorder paper, ink and battery is not necessary. Possibility of connection of several additional self-sufficient temperature sensors (up to 4 PT1000 & 2 PT100). Your essential advantages: One integrative system for collecting all temperature relevant appliances and ambients. Many different connection facilities allow flexible upgrades for individual projects. CON1: DC inlet CON2: Electronic CON3: ----- CON4-6: Add. sensors CON7:RS 232 CON8: RS 485 WLAN (option) Ethernet LAN USB All rights reserved. All indications without guarantee and excluding all liability due to faulty, incomplete or outdated information. All technical data subject to change without prior notice. DMN & DCU in combination offer a highly flexible system that is adaptable to specific customer requirements Complete & legally safe documentation of temperature data Comprehensive applications and diagnostic possibilities S.àr.l. Division Medical Systems 17, Op der Hei L-9809 Hosingen, Luxembourg Tel. : + 352 92 07 31-1 Fax : + 352 92 07 31-300 medical.systems@dometic.lu www.dometic.lu