Ecoflex Wall Penetration Systems: An efficient, sustainable solution for penetrating concrete or block walls



Similar documents
Installation instruction CASAFLEX - Connecting piece DN 100

Always. Reliable. Tight. Wall sleeves Versatile solutions for building entries. cablepipebuildingentry+

Packaged Terminal Air Conditioner Wall Sleeve Installation

Lenntech psi End port pressure vessels 2.5. User s Guide to: Phoenix Vessel Technology Limited. Model number: 1503

CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.

Saferand easierinstallation

INSTALLATION INSTRUCTIONS BL-8704

WATER SERVICE 2

INSTALLATION INSTRUCTIONS MK-8704

4-600, 1000 psi. User s Guide to: Phoenix Vessel Technology Limited. End port pressure vessels Model numbers: 1386, 1384.

TECHNICAL SPECIFICATION

SECTION STORM DRAINAGE SYSTEM

Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors

Guidelines for Earthquake Bracing of Residential Water Heaters

PANELIZED HOME INSTALLATION GUIDELINE

WAVELET WATER QUALITY MONITORING KIT

TEXAS A&M CENTRAL ACADEMIC BUILDIING & PATRIOT S CASA SUBMITTAL Pre-Insulated Piping

product manual H-4210A PORTABLE STATIC CONE PENETROMETER

Flue Installation. High Efficiency Condensing Boilers

ELECTRIC PERISTALTIC MORTAR POINTING PUMP

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

Designed and Engineered to Perform

This data sheet describes the most common joining methods of steel water mains and the most important phases of installation.

Carlon Bore-Gard and Boreable Multi-Gard Raceway

Universal Installation and Maintenance Instructions Double Wall Spill Containment Bucket (5 and 15 gal)

GPD Rubber Press Seals

Folding Bath Screen Instruction Manual

Installation Manual. SKU# series (Base Rails) SKU# series (Overhead Racks)

Wastewater Capital Projects Management Standard Construction Specification

Owner's Manual & Assembly Instructions

Permanent Stainless Steel Anchorage Point for Concrete, Solid Masonry and Steel Constructions

STEERING HANDLEBAR/FRONT WHEEL/ FRONT SHOCK ABSORBER

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

SMarT_Foundation [Simple Modular Technology] Assembly and Installation Instructions (U.S. Patent Pending)

Installation Instructions

Select Radiators Installation Guide

A Solid Foundation Solution for Homeowners. from. Our products are made with 90% Recycled Material Down. Right. Solid. GREEN.

Watts Pure Water Systems

4 Installation Requirements

Up-Down Construction Utilizing Steel Sheet Piles and Drilled Shaft Foundations

Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes

CONTENTS. Yale University Design Standards. Underground Electrical Duct Bank. A. Summary. B. System Design and Performance Requirements

Foundation Experts, LLC Specializes in Foundation Repair and Waterproofing

SECTION CEMENT-MORTAR LINED AND COATED STEEL PIPE

Installation Instructions for Contractors. Connection Sets. Solar Twin Tube. Inox 1/2" Inox 3/4" (2011/02) US/CA

CITY OF SELMA, TEXAS Inspection Checklist: Commercial

Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17)

GENERAL SPECIFICATION FOR CIVIL ENGINEERING WORKS SECTION 13 WORK FOR ELECTRICAL AND MECHANICAL INSTALLATIONS

AZEK Rail Install Guide

Step-by-step instructions:

Drive shaft, servicing

I BEAM TRACK INSTALLATION

Char-Lynn Hydraulic Motor. Repair Information Series. October, 1997

1. Lay out 2 pieces of 7/8" tubing and mark for bending as shown. Remember that the bend is in the shaded area as shown below in Figure 1.

Chapter. Restoration of Damaged Structures

Ocean Engineering Technical Data Sheet Stuffing Tubes

Close Coupled & Back To Wall WC Saintaryware. Fitting Instructions

WATERPROOFING OF WET ROOMS

Embedded Parts Introduction - Anchors

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

FOR ANY QUESTIONS, PLEASE CALL M-F 8:00a.m.-8:00p.m. EST. REAR BRAKES 1 AEROSPACE COMPONENTS

PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE. By H P Gupta & D K Gupta

USER MANUAL. 10 GPM Small Single Line Cryogenic Coupling

DOUBLE CONTAINMENT DESIGN & INSTALLATION GUIDE

Guidelines for Earthquake Bracing Residential Water Heaters

SECTION SANITARY SEWER AND STORM DRAIN SYSTEMS

Check for deteriorated, shifting or missing tie-down pads. Replace if needed.

Seismic Installation for Attic Storage System

Active and Passive Sash Replacement

Puddle Flange. FRANK Puddle Flange

theory FTHPL, T-RATED

Waterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries

SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

Owner's Manual & Assembly Instructions

Section SEWER PIPE INSTALLATION AND TESTING

SECTION ALUMINUM HANDRAIL AND RAILING SYSTEMS WITH DECORATIVE METAL PANEL INFILLS

Syphonic Roof Drainage

TRI-FOLD TONNEAU INSTALLATION GUIDE

How To Replace A Reverse Osmosis Water Tank

INSTRUCTIONS THOROUGHLY BEFORE BEGINNING***************

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

necessary for years of satisfactory service. SmartBlock insulating form concrete walls share the

Depending on which elastic support you have you can secure the V2 power unit to the following seat bracket tubes: EXTERNAL DIAMETER 27.

with installation dynafact boost GAUGE this manual is for use with systems

1.8 CRANKSHAFT OIL SEALS

MILMAN & ASSOCIATES STRUCTURAL CONSULTING ENGINEERS/ PROJECT MANAGERS

TRANS-05, Torque Tube Removal, Rebuilding, and Installation

Replacement Window Installation Guide Non-Impact & Impact Resistant Windows without Nailing Fin

IN00419 (rev A) Aqua 6 Glide Quadrant and Off-set Quadrant Enclosure

CCU Engineering Specifications. Section PRECAST CONCRETE PRODUCTS

INSPECTION, MAINTENANCE AND RECHARGE SERVICE MANUAL P/N 16303

Policy on Water Heater Installations Policy No. UPC Effective: September 1, 1995 Revised: February 10, 1996

Tremco Fire Protection Systems Group Technical Bulletin

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona

GENERAL RUBBER LINING PRINCIPLES

W I T H I N J O I ST S I N STA L L AT I ON

T R A N S F E R A B L E F U L LY

Micropiles Reduce Costs and Schedule for Merchant RR Bridge Rehabilitation

7. Installation. installation CAST-IN WINDOW SYSTEM 7.1. INSTALLATION OF WINDOW MAIN FRAME

Contact Information: Electrical Connection Kit for CL Series Constant Wattage Temptrace for Low Temperature Maintenance.

Transcription:

Pre- insulated pipe systems ecoflex Wall Penetration installation guide Ecoflex Wall Penetration Systems: An efficient, sustainable solution for penetrating concrete or block walls

Pre-insulated Pipe Systems Wall Penetration Installation Guide Table of Contents Wall Penetration Options... 1 Wall Sleeve with Heat Shrink Seal Kit...1 Wall Sleeve...1 Compression Wall Seal...1 Wall Penetrations....2 New Concrete Block or Existing Wall...2 New Concrete Wall....2 Existing Wall with Field Core Drill...2 Installation Methods...2 Required Components...2 Compression Wall Seal...3 Cores Holes in Water-impermeable Concrete...3 Wall Sleeve Installation...4 Installing the Wall Seal into the Core Hole or Wall Sleeve...5 Wall Sleeve with Heat Shrink Seal Kit Installation Method...6 Tools Required....6 Slab-on-grade Installation...8 Dry Well...8 Slab-on-grade Through Knockout Installation Outside Wall Attachment.... 9 Slab-on-grade Through Sleeve Installation Interior Wall Attachment.... 10 Slab-on-grade Under Footing Installation Interior Wall Attachment... 11 Slab-on-grade Dry Well Installation Interior Wall Attachment... 12 ii www.uponor-usa.com www.uponor.ca

Wall Penetration Options Wall Sleeve with Heat Shrink Seal Kit Uponor s Wall Sleeve with Heat Shrink Seal Kit offers a simple solution for new concrete walls, new-block construction or installation in an existing wall with an irregular hole. Wall Sleeves, though not engineered for specific bearing loads, offer installation convenience and compatibility. Compression Wall Seal Use the Compression Wall Seal with the Wall Sleeve or use alone when a field core drill is preferred. Figure 3: Compression Wall Seal Figure 1: Wall Sleeve with Heat Shrink Seal Kit Wall Sleeve Uponor s Wall Sleeve with the Compression Wall Seal (sold separately) offers a simple solution for new concrete walls, new-block construction or installation in an existing wall with an irregular hole. The Wall Sleeve can be field cut for proper fit within concrete forms. Wall Sleeves, though not engineered for specific bearing loads, offer installation convenience and compatibility. If a field core drill is preferred, use the Compression Wall Seal alone. Refer to Table 1 for the required core drill size. Wall Seal Part No. Jacket Size Table 1: Core Drill Sizes Core Drill Size Wall Seal Length Compatible Wall Sleeve 1007360 5.5" 8" 4" 1007365 1007361 6.9" 10" 4" 1007366 1007362 7.9" 10" 4" 1007366 Figure 2: Wall Sleeve Uponor Pre-insulated Pipe Systems Design and Installation Guide 1

Wall Penetrations Use this section for tips on watertight penetration of a concrete wall. New Concrete Block or Existing Wall For new concrete block or existing walls, Uponor offers the Wall Sleeve with Heat Shrink Seal Kit. The Wall Sleeve can be used with the Compression Wall Seal for block-wall installations or for irregular holes in existing walls. The Wall Sleeve can easily be grouted into place in the irregular hole. Either the Heat Shrink Seal Kit or the Compression Wall Seal will ensure a watertight connection between the Wall Sleeve and the Ecoflex outer jacket. Uponor recommends routing the pipe as straight as possible through the Wall Sleeve to ensure a proper seal. Refer to Figure 4 for an example of a Wall Sleeve with Heat Shrink Seal Kit installation. Existing Wall with Field Core Drill The Compression Wall Seal creates a watertight seal between the core drill surface and the outer jacket of the Ecoflex pipe (see Figure 5). Figure 5: Compression Wall Seal Note: this type of wall penetration requires the following. Core drill Compression Wall Seal (See Figure 5) Figure 4: Wall Sleeve with Heat Shrink Seal Kit New Concrete Wall When requiring a watertight penetration of a new concrete wall, cut the Wall Sleeve in the field for a proper fit between the concrete forms. The Compression Wall Seal is a mechanical expansion device installed over the pipe and into the Wall Sleeve to provide a watertight seal. Note: The above wall penetrations require the following. Wall Sleeve Compression Wall Seal (See Figure 7) Wall Sleeve with Heat Shrink Seal Kit (See Figure 4) Installation Methods This section illustrates the various Wall Seal installation applications. Typical examples show procedures for use. Applications vary depending on installation design requirements. Required Components Tools and components needed for this installation include the following. Compression Wall Seal with included hardware Wall Sleeve (optional) Epoxy resin Protective end caps or plastic covering Pipe clamp (optional) Cutting tools Drill (optional) Figure 6: Wall Seal, Pressure Waterproof up to 7.0 psi (0.5 bar) 2 www.uponor-usa.com www.uponor.ca

Compression Wall Seal Use the Uponor Wall Seal to provide sealing against high-pressure water. Insert the Wall Seal into the core hole or casing pipe on the outside wall. When installing, insert Wall Seal with nuts facing toward the inside wall or basement side. Core Holes in Water-impermeable Concrete At the designated area, bore through the wall with an appropriate cement drill. Use the Compression Wall Seal with the Wall Sleeve or alone in applications where a field core drill is preferred. Uponor Ecoflex Jacket Core Hole 5.5" 8" 6.9" 10" 7.9" 10" Table 2: Core Hole Sizes Figure 8: Drill the Core Hole After drilling, protect the bore wall with epoxy resin. Wearing protective gloves, cover the inside cut of the core hole according to the directions on the resin container. Figure 7: Wall Sleeve, Pressure Waterproof up to 7.0 psi (0.5 bar) For new concrete walls, use the Wall Sleeve with the Compression Wall Seal to simplify the installation process. It is easy to cut for proper fit within concrete forms. The Wall Sleeve offers an extra convenience for the installer. The Wall Sleeve provides a tight seal under pressurized water and is easy to cast when pouring new cement walls. Figure 9: Protect the Bore Wall with Epoxy Resin Uponor Pre-insulated Pipe Systems Design and Installation Guide 3

Protect the bore from contamination and moisture during the unfinished phase of the installation. Tape plastic over the core hole on both sides of the wall, or insert protective end caps (supplied by installer) onto both sides of the core hole as shown in Figure 10. Fasten a steel framework to the Wall Sleeve so it is either flush with or protruding from welded joints or with a pipe clamp (supplied by the installer). Figure 14: Fastened in Steel Framework Figure 15: Built into a Wall Figure 10: Protect the Bore during Installation Uponor Ecoflex Jacket Core Hole 5.5" 8" 6.9" 10" 7.9" 10" Table 3: Core Hole Sizes Figure 16: Compact the Cement Wall Sleeve Installation If pouring new walls, cast the Uponor Wall Sleeve at the same time. The special pipe casing in combination with the Wall Sleeve ensures a tight seal under pressurized water. Figure 17: Protect Core Openings Figure 18: Installed into a Floor or Ceiling Figure 11: Wall Sleeve Install the Wall Sleeve either flush with the casing or projected out from the wall casing (see Figures 12 and 13). It is also an option to build the Wall Sleeve directly into walls or install them into floors and ceilings as shown in Figures 15 and 18. When installing Wall Sleeves, compact the cement around the seams of the pipe casing thoroughly as shown in Figure 16. Figure 12: Flush with Casing Figure 13: Projected from Casing 4 www.uponor-usa.com www.uponor.ca

Protect the bore openings from contamination and moisture during the unfinished phase by inserting protective end caps or securely covering (taping) the bore with plastic. Table 4 shows the required size of the Wall Sleeve for specific sizes of Uponor Ecoflex. Install the Wall Seal at right angles to the pipe as shown. M ater side Uponor Ecoflex Jacket Wall Sleeve 5.5" 8" 6.9" 10" 7.9" 10" Table 4: Wall Sleeve Sizes Installing the Wall Seal into the Core Hole or Wall Sleeve Note: The following illustrations show the basement on the left side of the wall. Insert the Wall Seal flush with the end of the core hole on the outside wall (the water side). Note that nuts face toward the inside wall (the basement). basement basement Figure 19: Wall Seal Flush with Outside Wall water water side side Figure 21: Install Wall Seal at Right Angles to Pipe When tightening to the maximum torque, keep the following in mind. During final assembly, successively tighten each nut clockwise with a torque wrench to reach the maximum torque (Mmax = 5 Nm (M6)/3.7 lbf ft; Mmax = 8 Nm (M8)/5.9 lbf ft). Tighten the nuts several times. Repeat this procedure after two hours. To ensure no damage to the Ecoflex jacket, tighten the nuts of the Uponor Wall Seal until the rubber seal wraps around the Ecoflex jacket pipe and the core hole, or if used, the Wall Sleeve. Figure 20 illustrates the correct and incorrect way to install the Wall Seal. The house lead-ins are neither fixed points nor supports and serve solely to provide an elastic seal for the jacket pipes of Ecoflex. The installer can gently turn the Ecoflex jacket pipes in an axial motion. Before filling in the pipe trench, place compressed, stoneless sand under the Ecoflex piping so no additional stress can affect the seal. M max = 5 N M max = 8 N M M Figure 20: Correct and Incorrect Wall Seal Installations Caution: Make sure the nuts are facing toward the basement when inserting the Wall Seal. M max = 5 Nm (M6)/3.7 lbf ft M max = 85 Nm (M8)/5.9 (M6)/3.7 lbf ft M max = 8 Nm (M8)/5.9 lbf ft Figure 22: Tighten to Maximum Torque M M max = 5 Nm (M6)/3.7 lbf ft M max = 8 Nm (M8)/5.9 lbf ft Uponor Pre-insulated Pipe Systems Design and Installation Guide 5

Wall Sleeve with Heat Shrink Seal Kit Installation Method This section illustrates how to install the Wall Sleeve with Heat Shrink Seal Kit in a typical application. Applications vary depending on installation design requirements. Tools Required Tools and components needed for this installation include the following. Wall Sleeve with Heat Shrink Seal Kit Brush (scrub/utility) Clean Rag Torch (medium flame) Soap (non-casutic) Figure 25: Fastened in Steel Framework Figure 26: Built into a Wall You can also build the Wall Sleeve directly into walls as shown in Figures 25 and 26. When installing Wall Sleeves, compact the cement around the seams of the pipe casing thoroughly as shown in Figure 27. Figure 23: Wall Sleeve with Heat Shrink Seal Kit If pouring new walls, you can cast the Uponor Wall Sleeve at the same time. The special pipe casing in combination with the Heat Shrink Seal Kit ensures a water tight seal. Install the Wall Sleeve projected out from the wall casing a minimum of 4" (see Figure 24). Figure 27: Compact the Cement Protect the bore openings from contamination and moisture during the unfinished phase by inserting protective end caps or securely covering (taping) the bore with plastic. 4" Figure 28: Protect Core Openings Table 5 shows the required size of the Wall Sleeve for specific sizes of Uponor Ecoflex. Figure 24: Projected from Casing You can fasten a steel framework to the Wall Sleeve so it is either flush with or protruding from welded joints or with a pipe clamp (supplied by the installer). Uponor Ecoflex Jacket Wall Sleeve 5.5" 1018269 6.9" 1018270 7.9" 1018268 Table 5: Wall Sleeve Sizes Note: Before Installing Ecoflex pipes through a Wall Sleeve, ensure grout is fully cured. 6 www.uponor-usa.com www.uponor.ca

You can install Ecoflex pipes before the Wall Sleeve is grouted into place if the pipes are fully installed and pressure tested before the wall sleeve is grouted into the wall. Install Heat Shrink Seal Kit over the Ecoflex piping before installing the piping through the Wall Sleeve as shown in Figure 29. Using a soft, medium flame, preheat the Wall Sleeve and Ecoflex pipe, keeping the flame in constant motion as shown in Figure 32. max. 160 ºF (70 ºC) 2 1 Figure 29: Heat Shrink Seal Kit over Ecoflex Pipe Note: Complete all connections and pressure test before proceeding. Prepare the surface by removing debris with a dry scrub brush as shown in Figure 30. Using a dry clean rag, clean both the Wall Sleeve and Ecoflex pipe of all debris in the full circumference of the area being sealed (approximately 4" to 6" on each side.) Uponor recommends using soap or non-caustic cleanser to ensure the surface area is completely clean prior to sealing the kit. Ensure the surface area is thoroughly dry after cleaning. Figure 32: Preheat Wall Sleeve Slide the Heat Shrink Seal Kit evenly over the Wall Sleeve and Ecoflex pipe. Evenly apply heat to the Heat Shrink Seal Kit starting from the wall and working toward the Ecoflex pipe, being careful not to overheat the compenents (see Figure 33). O.K. PE Figure 33: Apply Even Heat Remember to use continuous movements with the torch and never apply direct flame to the surface of the pipe or Heat Shrink Seal Kit. The temperature of the surface should never exceed 158ºF (70ºC). Figure 30: Prepare Suface Remove plastic liner from Heat Shrink Seal Kit before applying heat as shown in Figure 31. min. 2" min. 2" Figure 34: Wall Seal with Heat Shrink Seal Kit Figure 31: Remove Plastic Liner Uponor Pre-insulated Pipe Systems Design and Installation Guide 7

Figure 35: Slab-on-grade Installation Example Slab-on-grade Installation In most cases, Ecoflex piping makes slab-on-grade installations easy. Ecoflex pipe jackets are safe for direct contact with concrete or mortar. Occasionally, the trench will require additional depth adjacent to the building to accommodate the bend radius of the Ecoflex pipe. To secure the pipe radius during construction, simply use a suitable strap to tie the end of the pipe back a short distance upon itself. Place a reinforcement bar in the soil and secure the pipe to it to avoid lateral movement during construction, as illustrated in Figure 35. See Figures 36 through 47 for other variations of slab-on-grade installation methods. Dry Well If you cannot achieve a suitable trench depth to allow for the bend radius, construct a concrete dry well to provide accessible space for fitting connections (see Figures 39, 46 and 47). Figure 36: Slab-on-grade Installation Example Figure 3-20: Dry Well Figure 39: Concrete Dry Well Figure 37: Slab-on-grade Installation Example Figure 38: Slab-on-grade Installation Example 8 www.uponor-usa.com www.uponor.ca

Slab-on-grade Through Knockout Installation Outside Wall Attachment Wirsbo hepex tubing Secure fitting with anchor bracket ProPEX Brass Female Threaded Adapter and Male Threaded Adapter 6" min. Single Rubber End Cap Ecoflex Thermal Single Concrete Slab Concrete Stem Wall Figure 40: Slab-on-grade Through knockout Installation Outside Wall Attachment ProPEX Brass Female Threaded Adapter and Male Threaded Adapter Wirsbo hepex tubing Secure fitting with anchor bracket Single Rubber End Cap Concrete Slab Ecoflex Thermal Single Concrete Stem Wall Figure 41: Slab-on-grade Through knockout Installation Outside Wall Attachment Uponor Pre-insulated Pipe Systems Design and Installation Guide 9

Slab-on-grade Through Sleeve Installation Interior Wall Attachment Wirsbo hepex tubing Secure fitting with anchor bracket ProPEX Brass Female Threaded Adapter and Male Threaded Adapter Single Rubber End Cap Concrete Stem Wall Ecoflex Thermal Single Figure 42: Slab-on-grade Through Sleeve Installation Interior Wall Attachment Wirsbo hepex tubing ProPEX Brass Female Threaded Adapter and Male Threaded Adapter Secure fitting with anchor bracket Concrete Slab Single Rubber End Cap Ecoflex Thermal Single Concrete Stem Wall Figure 43: Slab-on-grade Through Sleeve Installation Interior Wall Attachment 10 www.uponor-usa.com www.uponor.ca

Slab-on-grade Under Footing Installation Interior Wall Attachment Wirsbo hepex tubing Wirsbo hepex tubing Secure fitting with anchor bracket ProPEX Brass Female Threaded Adapter and Brass Male Threaded Adapter Secure fitting with anchor bracket ProPEX Brass Female Threaded Adapter and Male Threaded Adapter Single Rubber End Cap Ecoflex Thermal Single Single Rubber End Cap Ecoflex Thermal Single Concrete Slab Concrete Slab Concrete Stem Wall Concrete Stem Wall Figure 44: Slab-on-grade Under Footing Installation Interior Wall Attachment Figure 45: Slab-on-grade Under Footing Installation Interior Wall Attachment Uponor Pre-insulated Pipe Systems Design and Installation Guide 11

Slab-on-grade Dry Well Installation Interior Wall Attachment Slab-on-grade UDnder Footing Installation Interior Wall Attachment Wirsbo hepex tubing Concrete Slab Secure fitting with anchor bracket Ecoflex Thermal Single ProPEX Brass Female Threaded Adapter and Male Threaded Adapter Concrete Stem Wall Single Rubber End Cap Figure 46: Slab-on-grade Dry Well Installation Interior Wall Attachment Concrete Stem Wall Wirsbo hepex tubing Single Rubber End Cap Ecoflex Thermal Single Secure fitting with anchor bracket ProPEX Brass Female Threaded Adapter and Male Threaded Adapter Figure 47: Slab-on-grade Dry Well Installation Interior Wall Attachment 12 www.uponor-usa.com www.uponor.ca

Uponor Pre-insulated Pipe Systems Design and Installation Guide 13

PIPS_Wallpenet_InsG_0511, Copyright 2011 Uponor, Printed in the United States Uponor, Inc. 5925 148th Street West Apple Valley, MN 55124 USA Tel: 800.321.4739 Fax: 952.891.2008 Web: www.uponor-usa.com Uponor Ltd. 2000 Argentia Rd., Plaza 1, Ste. 200 Mississauga, ON L5N 1W1 CANADA Tel: 888.994.7726 Fax: 800.638.9517 Web: www.uponor.ca