1 V I C T A U L I C P I P I N G S O L U T I O N S F O R D A T A C E N T E R F A C I L I T I E S When every minute counts, choose the solution that makes a difference.

2 Victaulic PIPING. SYSTEMS. SOLUTIONS. As the world leader in mechanical piping systems, Victaulic has set the global standard for piping efficiency, engineering expertise and performance reliability by protecting, heating and cooling buildings all over the world. From performing under pressure in the Hoover Dam to protecting ancient treasures in Egypt, Victaulic has been trusted for 85 years to provide quality products that meet the most demanding industry challenges. Hoover Dam - United States Supplies 16 million people with water every day Generates 4 billion kilowatt hours of hydroelectric energy annually Outfitted with Victaulic mechanical piping products because they installed quickly and easily with only minimal service disruptions Alexandria Library - Egypt Home to priceless ancient artifacts from around the world The Library required unparalleled piping system reliability Victaulic products for both HVAC and Fire Protection systems were trusted throughout the building 2 Data Centers

3 Trust Victaulic to protect and cool your mission critical facilities. As more and more data centers transition to water systems as the most efficient method of cooling - 4,000 times more efficient than air - owners and engineers demand only the most reliable piping systems are used in their facilities. Whether cooling, heating or protecting your data center facility, Victaulic has the products and solutions to get your data center up and running quickly and operating efficiently. Data Centers 3

4 Compressed Project Schedules Victaulic mechanical piping systems are three to five times faster to install than traditional joining methods. Meet and exceed the flashtrack schedules associated with data center construction. Quicker, easier installations 3 TO 5 TIMES FASTER TO INSTALL MAN HOURS PER JOINT Grooved Flanged Welded 2" 4" 6" 8" 10" 12" PIPE SIZE Victaulic benefits that save you time and valuable resources. IMPROVED SAFETY No flame joining method LABOR SAVINGS Easier maintenance and system expansion DESIGN VERSATILITY More options and easily accomodates system change 4 Data Centers

5 Welded systems demand 45% more man-hours on average compared to Victaulic no-flame piping solutions. The math is simple: less man-hours equals less exposure and project risk. Victaulic will increase project efficiency and reduce field man-hours from start to finish with value added services. Shift Maximum Manpower Line Welded Peak Man-Power VICTAULIC SERVICES INCLUDE: Estimating Pre-Planning and Project Management NUMBER OF MEN ON SITE Victaulic Peak Man-Power Meet or Beat Project Schedule Jobsite Training MECHANICAL CONSTRUCTION WEEKS Software Solutions Data Centers 5

6 Seismic Performance Testing Natural disasters happen, but when there is no time for downtime, planning ahead can make a world of difference. Piping systems located in earthquake prone areas are likely to be exposed to forces and deflections beyond normal static conditions and the results can be catastrophic. Victaulic components can accommodate seismic forces in the following piping system conditions. Code-regulated systems with adequate earthquake bracing Unregulated systems with little or no earthquake bracing Seismic joint connections between independently-moving sections Buried systems Seismic swing joint utilizing Victaulic mechanical piping components 6 Data Centers

7 Testing performed at the Real-Time Multi-directional Experimental Laboratory at the Center for Advanced Technology for Large Structural Systems at Lehigh University in Bethlehem, PA, USA proved the suitability of Victaulic grooved mechanical couplings to maintain operational integrity of piping systems during seismic events. Victaulic couplings ranging in size from 4-16 / mm were exposed to accelerations up to 50% greater than the Northridge, California earthquake. The water-filled assemblies were pressurized to 200psi/1375 kpa for the duration of all tests and no pressure loss or leakage was noted during any of the tests. Data Centers 7

8 Anatomy of a Grooved Joint The versatility, reliability and speed of Victaulic mechanical pipe joining systems makes them ideal for use in data center applications. By specifying and installing Victaulic, engineers, owners and installation contractors conserve time and financial resources through: COMPRESSED PROJECT SCHEDULES Victaulic systems increase project efficiency from the start LOWERED TOTAL INSTALLED COST Over the lifetime of the system SAFER WORK ENVIRONMENT Reduced calendar days reduces exposure to job site accidents REDUCED SYSTEM DOWNTIME during scheduled maintenance and service checks 8 Data Centers

9 MAINTAINABILITY Victaulic systems provide easy accessibility when conducting preventative systems maintenance, resulting in a continued high level of energy efficiency and little to no downtime required. VALUE ADDED ENGINEERING At the root of all the benefits that Victaulic solutions bring to a project - such as jobsite productivity, safety, design flexibility and quality - are the unique features of its products. Maintenance plans are a critical element to every data center. Whether maintaining computer equipment or cooling equipment, system shut downs are limited to mere minutes. By using Victaulic mechanical piping systems, changing out inefficient equipment is as easy as loosening two bolts and two nuts. There is no need and no time required to cut out sections of pipe and re-weld. A UNION AT EVERY JOINT Removal of two couplings permits removal of a pipe section for replacement, cleaning or servicing. Exaggerated for clarity Expansion Contraction Roll Grooving Coupling Assembly Expansion Deflection Contraction Expansion & Contraction Deflection Deflection Capabilities Data Centers 9

10 Data Center Mechanical Room To get your data center up and running quickly, Victaulic offers a full line of couplings, fittings, valves and accessories for use throughout a facility s mechanical room. 1ST FLOOR MECHANICAL ROOM End Suction Pumps Mechanical Room Piping Condenser Water Units 10 Data Centers

11 From pumps and chillers to air handling units and cooling towers, Victaulic mechanical piping systems provide a fast, safe, reliable connection ideal for data center applications. Chillers Horizontal Split Case Pump Data Centers 11

12 BOM 7 BOM 9 Data Center Distribution Piping Victaulic products are ideal for use in data center distribution piping because they install quickly and easily, provide a safe, reliable pipe connection and easily accommodates tight space constraints. 2ND FLOOR DATA CENTER Future DN. Victaulic couplings and fittings are ideal for use in tight spaces CHASE Victaulic rigid couplings for straight runs of pipe Future Branch connections made easy using Victaulic products 12 Data Centers

13 Mechanical Room Connection to Second Floor Distribution Piping (Under-floor piping) MECH. CHASE Future Future Victaulic couplings and elbows Future Future MECH. CHASE ELECT. CHASE BELOW DN. Future 1' " DN. FM-200 CHASE BELOW Future Future Future Victaulic offers a full line of piping systems components Future Future Victaulic butterfly valves for dead-end shutoff Data Centers 13

14 VictaulicVortex Fire Suppression Protecting Equipment, Personnel and the Environment Until now, fire suppression meant damaged equipment, lengthy and costly clean up, and lost productivity. Now, data center owners can breathe a little easier knowing their equipment and environment are protected by the VictaulicVortex Fire Suppression System. Made entirely of non-toxic agents personnel are safe even during activation; reduction of oxygen in the space is at levels within safe breathing tolerances. System activation is immediate when sensors detect smoke or heat there is no delay in activation to evacuate personnel to avoid a toxic environment. VictaulicVortex The only hybrid nitrogen-water fire suppression system Nearly ZERO wetting of protected areas No ozone depleting or greenhouse gas emissions Quick system recharge to support minimal facility downtime My clients were very impressed with the VictaulicVortex system when they saw the level of fire protection it provides without huge amounts of water or toxic chemicals. It s all about protecting the people and assets, minimal impact on the hazard environment and the fast return to normal operations. The Vortex system delivers. TOM EUSON, 3S INCORPORATED 14 Data Centers

15 VictaulicVortex in a Data Center The system fully extinguishes fires in enclosed cabinets and isolated equipment within protected spaces. Zones can be centrally controlled yet independently activated for fire suppression only where required. The system delivers as little as one gallon of water per emitter per minute: each emitter can protect up to 2,500 cubic ft. The system is compatible with facility fire protection systems providing greater design flexibility. System is recharged rapidly allowing for a return to working conditions almost immediately after a fire. Data Centers 15

16 Global Data Center Project Successes From the United States to Singapore, Victaulic mechanical piping systems are trusted all over the world to protect, heat and cool data centers. 16 Data Centers

17 Data Centers 17

18 Global Data Center Project Successes 18 Data Centers

19 Data Centers 19

20 The Victaulic website is an information resource that can help you with your piping projects. Among the many resources available at the site: Fully searchable product and project databases Free product submittals Free product literature Piping software demos, modules and downloads. Information on new product innovations Support services, and more... ENGLISH VICTAULIC LOCATIONS VICTAULIC GLOBAL CONTACT INFORMATION US & WORLD HEADQUARTERS CANADA UNITED KINGDOM ASIA PACIFIC P.O. Box 31 Easton, PA USA 4901 Kesslersville Road Easton, PA USA PICK-VIC ( ) (fax) Newkirk Road Richmond Hill, ON L4C 3G (fax) EUROPE Prijkelstraat Nazareth, Belgium (fax) Units B1 & B2, SG1 Industrial Park Cockerell Close Gunnels Wood Road Stevenage Hertfordshire, SG1 2NB (UK) +44 (0) (0) (fax) CENTRAL AND SOUTH AMERICA P.O. Box 31 Easton, PA USA 4901 Kesslersville Road Easton, PA USA (fax) 3A/F, A Mansion, No. 291 Fumin Road, Shanghai , China (fax) [email protected] MIDDLE EAST P.O. Box Unit XB 8 Jebel Ali Free Zone Dubai United Arab Emirates (fax) MB Rev.C VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY VICTAULIC COMPANY. ALL RIGHTS RESERVED.

Commercial Building Services

Commercial Building Services Commercial Building Services Victaulic Original Invention Mechanical pipe joining technology originated in 1925 when Victaulic designed the first grooved end pipe joining system for water and air service

More information

For Data Center and Control Room Applications

For Data Center and Control Room Applications For Data Center and Control Room Applications Nearly zero wetting No costly clean up or equipment replacement Sustainable design Quick system recharge, minimal downtime No need for assurance of tight room

More information

For Data Center and Control Room Applications

For Data Center and Control Room Applications For Data Center and Control Room Applications Nearly zero wetting No costly clean up or equipment replacement Sustainable design Quick system recharge, minimal downtime No need for assurance of tight room

More information

Victaulic Total Piping Solutions

Victaulic Total Piping Solutions CONSTRUCTION Construction Piping Services Victaulic Total Piping Solutions From estimating through construction, we re with you every step of the way, ensuring the highest quality and most efficient implementation

More information

DATA CENTER FIRE PROTECTION

DATA CENTER FIRE PROTECTION DATA CENTER FIRE PROTECTION DATA CENTER FIRE PROTECTION The following is a summary of a few key fire protection, detection, and suppression technologies used by Minimax Fire Solutions in data centers and

More information

HDPE Pipe Joining System

HDPE Pipe Joining System HDPE Pipe Joining System The System The fast, easy, and economical way to mechanically join HDPE pipe. Fast, easy bolted connection Faster installation Easy to remove and rotate pipe for increased pipe

More information

Safer.Smarter.Tyco. Watermist fire protection Technology you can trust

Safer.Smarter.Tyco. Watermist fire protection Technology you can trust Safer.Smarter.Tyco. Watermist fire protection Technology you can trust / 2 / / 3 / Trust in Tyco Tyco s AquaMist Systems Tyco Fire Protection Products helps to keep people, property and the environment

More information

Introduction Insurance Industry Overview and Major Trends

Introduction Insurance Industry Overview and Major Trends Page 01 of 13 Page 02 of 13 Page 03 of 13 Page 04 of 13 Page 05 of 13 Page 06 of 13 Page 07 of 13 Page 08 of 13 Page 09 of 13 Page 10 of 13 Page 11 of 13 Page 12 of 13 Page 13 of 13 India- Corporate Headquarters

More information

Style 07 Zero Flex Rigid Coupling. Style 75 Flexible Coupling. Style 77 Flexible Coupling 11. Description

Style 07 Zero Flex Rigid Coupling. Style 75 Flexible Coupling. Style 77 Flexible Coupling 11. Description Style 07 Zero Flex Rigid Coupling The unique angled pad design adjusts to standard pipe tolerances to positively clamp the pipe to resist flexural and torsional loads. Working pressures are based on standard

More information

Alarm and Detection/Suppression

Alarm and Detection/Suppression Alarm and Detection/Suppression Fire Safety American Fire Technologies To provide special hazard services world wide to the industrial market through the integration of components and services Clean Agent

More information

PLBG/GAS SAFETY Information Bulletin

PLBG/GAS SAFETY Information Bulletin PLBG/GAS SAFETY Information Bulletin November 2012 P/G-08-02-PLBG/GAS [Rev 3] Page 1 of 11 SUBJECT: REQUIREMENTS FOR COMBINATION HEATING SYSTEMS: DUAL PURPOSE WATER (POTABLE) HEATER (COMBO UNIT) Safety

More information

PIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT

PIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT PIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT GENERAL INFORMATION 1.1 This section applies to piping systems for chilled water, hot water, condenser water, steam, condensate return, fuel oil, refrigerant

More information

Disaster Ready. By: Katie Tucker, Sales Representative, Rolyn Companies, Inc

Disaster Ready. By: Katie Tucker, Sales Representative, Rolyn Companies, Inc By: Katie Tucker, Sales Representative, Rolyn Companies, Inc Are you and your facility disaster ready? As reported by the Red Cross, as many as 40 percent of small businesses do not reopen after a major

More information

District Cooling Best Practices Piping Systems

District Cooling Best Practices Piping Systems District Cooling Best Practices Piping Systems International District Cooling Conference January 14-17, 2007 Abu Dhabi, United Arab Emirates Bryan Kleist Agenda Chiller Water Piping Materials Pipe Insulation

More information

60.12. Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING

60.12. Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING 60.1 D-O-L FxE expansion couplings are a bolted, split-sleeve design that provides for expansion and contraction at the coupled joint. These couplings are furnished with restraint rings that, when affixed

More information

General Fire Code Requirements Within Commercial Tenant Spaces

General Fire Code Requirements Within Commercial Tenant Spaces FIRE DEPARTMENT in cooperation with Scope: General Fire Code Requirements Within Commercial Tenant Spaces This handout is designed to assist owners, architects, contractors and others in understanding

More information

Steel Fire Sprinkler Pipe

Steel Fire Sprinkler Pipe Steel Fire Sprinkler Pipe Wheatland Tube Fire Sprinkler Products Wheatland Tube began producing steel fire sprinkler pipe in 1931, and today offers the most complete line of products in the industry. Engineers

More information

Using Autodesk Fabrication Software from TSI

Using Autodesk Fabrication Software from TSI Using Autodesk Fabrication Software from TSI Photo courtesy of Lend Lease COMPANY BACKGROUND Walsh Mechanical Contractors is a full service, commercial mechanical contractor serving Eastern New England,

More information

RFI Response RFP: HSCG88-16-R-PQQ015 Replace HVAC Bldg A & C San Diego, CA.

RFI Response RFP: HSCG88-16-R-PQQ015 Replace HVAC Bldg A & C San Diego, CA. 1. There is verbiage in the hazardous material report referring to a state licensed abatement contractor. Within the recommendations part of the report (page 64 of 111 of the specification pdf) is the

More information

Rental Services Temporary Cooling - Flexible Water Hose

Rental Services Temporary Cooling - Flexible Water Hose Engineering Bulletin Rental Services Temporary Cooling - Flexible Water Hose September 2006 CHS-PRB007-EN Warnings and Cautions Warnings and Cautions. Notice that warnings and cautions appear at appropriate

More information

NMSU FIRE DEPARTMENT Commercial Kitchen Fire Suppression Worksheet

NMSU FIRE DEPARTMENT Commercial Kitchen Fire Suppression Worksheet This Commercial Kitchen Automatic Fire has been created to assure all documentation has been submitted to assist you in assuring proper plans and documentations has been submitted and reviewed by New Mexico

More information

Commissioning - Construction Documents (Page 1 of 6)

Commissioning - Construction Documents (Page 1 of 6) Commissioning - Construction Documents (Page 1 of 6) A. General Information Climate Zone: Building Type: Conditioned Area (sf): Reviewer's Name: Reviewer's Agency: Note: Design Review for each system/subsystem

More information

TYPICAL FIRE SAFETY INSPECTION VIOLATIONS

TYPICAL FIRE SAFETY INSPECTION VIOLATIONS TYPICAL FIRE SAFETY INSPECTION VIOLATIONS The following is a list of typical violations often found by inspectors and a generic solution. You can use this list to improve the safety of your facility, to

More information

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION Fire Pump Plan Review 2009 International Fire Code and NFPA 20 Date of Review / / BLD201 - Project Address: Project Name: Contractor s Business

More information

08.09. Triple Service Valve Assembly

08.09. Triple Service Valve Assembly SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS Victaulic Tri-Service valve is an assembly (shipped as individual components) of a standard Victaulic butterfly or Vic-Plug valve and a check valve. This combination

More information

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC) APPLICATIONS Process Industry Weak Acids Alkalies Compressed Air Pulp & Paper MODELS ASM - Flanged Connection OPTIONS Control Rods Oil & Gas Water & Waste Pump suction & discharge Sea water Chemical lines

More information

Scalable. Affordable. Flexible. Fast.

Scalable. Affordable. Flexible. Fast. Modular Data Center Solutions Scalable. Affordable. Flexible. Fast. Build the data center you need today with the flexibility to meet tomorrow s challenges The only constant in business is change. Fluctuations

More information

DESIGN CRITERIA. Determination of earthquake demand. Building importance level. Component categories SEISMICALLY RESILIENT NON-STRUCTURAL ELEMENTS

DESIGN CRITERIA. Determination of earthquake demand. Building importance level. Component categories SEISMICALLY RESILIENT NON-STRUCTURAL ELEMENTS FACT SHEET 2 NZS 4219:2009 Seismic performance of engineering systems in buildings requires the arrangement and layout of engineering systems within a building to allow for earthquake actions. NZS 4219:2009

More information

Data Center Network Infrastructure The Smart Choice For Your Data Center

Data Center Network Infrastructure The Smart Choice For Your Data Center Data Center Network Infrastructure The Smart Choice For Your Data Center Network Infrastructure Expertise Unrivaled Quality, Service, and Support Innovative Solutions Custom Products Strong Return on Infrastructure

More information

Reliable Pressure Measurement with Remote Diaphragm Seals in Cold Weather Applications

Reliable Pressure Measurement with Remote Diaphragm Seals in Cold Weather Applications Reliable Pressure Measurement with Remote Diaphragm Reliable Pressure Measurement with Remote Diaphragm Introduction............................................................... page 1 Rosemount 3051S

More information

Mission-critical fire protection HI-FOG for data centres

Mission-critical fire protection HI-FOG for data centres Mission-critical fire protection HI-FOG for data centres Modern fire protection for a data-driven world We make a strong case that HI-FOG is the best available fire protection for mission-critical data

More information

Fire Pump Plan Review March 2010

Fire Pump Plan Review March 2010 Fire Pump Plan Review March 2010 Date of Review: / / Permit Number: Business/Building Name: Address of Project: Designer Name: Designer s Phone: Contractor: Contractor s Phone: Occupancy Classification:

More information

COMPRESSED GASES. 1.2 The contents of each cylinder and container must be clearly identified (by tag or stamp) on the cylinder.

COMPRESSED GASES. 1.2 The contents of each cylinder and container must be clearly identified (by tag or stamp) on the cylinder. Page 1 of 5 COMPRESSED GASES A compressed gas is defined as any mixture of gases in a container with a pressure exceeding 40 psi. at 70 o F, or 104 psi. at 130 o F; or any flammable liquid with an absolute

More information

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01. Section 5.0 Basements Wall insulated externally Product: Polyfoam ECO Ba01 Wall insulated internally Product: Polyfoam ECO Ba02 Basements Basements Basement design Waterproofing BS 8102: 2009 Code of practice

More information

building engineering services association specification for: Domestic Heating www.thebesa.com

building engineering services association specification for: Domestic Heating www.thebesa.com building engineering services association specification for: Domestic central Heating installation www.thebesa.com building engineering services association acknowledgments Guide to good practice: Domestic

More information

Data Centre Services. JT First Tower Lane Data Centre Facility Product Description

Data Centre Services. JT First Tower Lane Data Centre Facility Product Description JT First Tower Lane Data Centre Facility Product Description JT s Data Centre Hosting Service provides a secure computer room enviroment with protected incoming power supplies, state-of-the-art security

More information

Subject: County of Los Angeles Data Center Space Requirement

Subject: County of Los Angeles Data Center Space Requirement Subject: County of Los Angeles Data Center Space Requirement The County of Los Angeles, Chief Executive Office, Real Estate Division (CEO-RED) is issuing this Property Search for the purchase of a vacant,

More information

Consulting Engineering Outsourcing

Consulting Engineering Outsourcing Consulting Engineering Outsourcing Opportunities, challenges and strategies 5.º Fórum Lusófono das Comunicações Maputo, 24 de Abril de 2014 Maksen 2014 Consulting Engineering Outsourcing AGENDA 01. Data

More information

Emergency Shutoff Valves for Fuel, Oil and Gas Service. Approved by FM, CSA and TÜV

Emergency Shutoff Valves for Fuel, Oil and Gas Service. Approved by FM, CSA and TÜV Emergency Shutoff Valves for Fuel, Oil and Gas Service Approved by FM, CSA and TÜV FM & CSA Approved Emergency Shutoff Valves for Fuel, Oil and Gas Service Sometimes Things Go Wrong It s why we have safety

More information

Aerosol Fire Suppression. Your Choice for Special Hazard Fire Protection

Aerosol Fire Suppression. Your Choice for Special Hazard Fire Protection Aerosol Fire Suppression Your Choice for Special Hazard Fire Protection Traditional Special Hazard Fire Protection Centers Around Two Technologies Water deluge and chemical agent fixed systems protect

More information

Fire Protection Pumps

Fire Protection Pumps Experience In Motion Fire Protection Pumps Pump Supplier to the World Flowserve is the driving force in the global industrial pump marketplace. No other pump company in the world has the depth or breadth

More information

Certified HVAC - Refrigeration Training Program

Certified HVAC - Refrigeration Training Program FINAL CERTIFICATION AWARDED BY IMRTC - USA Certified HVAC - Refrigeration Training Program This highly specialized and concentrated Program is ideally suited to following individuals who: A people who

More information

KINETICS RISER SUPPORT SYSTEMS

KINETICS RISER SUPPORT SYSTEMS RISER DESIGN INPUT GUIDE There are many factors that impact the design of a Riser support system. Because many of these factors are not items that the Engineers at KNC can guess at and because they have

More information

NFPA31FuelOilPiping 1 Revised 3-1-11

NFPA31FuelOilPiping 1 Revised 3-1-11 NFPA 31 Fuel Oil Piping, Installation and Testing Chapter 8 Fuel Piping Systems and Components 8.1 Scope. This chapter shall apply to piping systems and their components used to transfer fuel oil from

More information

Natural Gas Solutions

Natural Gas Solutions Natural Gas Solutions Customized Skids for Pressure Regulating, Flow Control, and etering Complete Solutions for Reliable Natural Gas Delivery Whether you are a Consultant, EPC contractor, End user or

More information

Element D Services Plumbing

Element D Services Plumbing Medical Vacuum and Gas PART 1 - GENERAL 1.01 OVERVIEW A. This section addresses medical vacuum, waste anesthetic gas disposal, compressed air, oxygen, nitrous oxide, nitrogen and carbon dioxide systems.

More information

AFTER THE BIG ONE, WILL CRITICAL COUNTY SERVICES SURVIVE?

AFTER THE BIG ONE, WILL CRITICAL COUNTY SERVICES SURVIVE? AFTER THE BIG ONE, WILL CRITICAL COUNTY SERVICES SURVIVE? SUMMARY There is a 67% probability that Southern California will be hit by a magnitude 6.7 or larger earthquake in the next 30 years according

More information

Based on SG GSA Fire & Security Products Contract GS-07F-0396M, Mod PO-0099 January 30, 2013

Based on SG GSA Fire & Security Products Contract GS-07F-0396M, Mod PO-0099 January 30, 2013 SimplexGrinnell TXMAS ecommerce Ferguson Fire and Fabrication Sprinkler Price List Based on SG GSA Fire & Security Products Contract GS-07F-0396M, Mod PO-0099 January 30, 2013 Product ID Description TXMAS

More information

FACILITY FIRE PREVENTION AND EMERGENCY PREPAREDNESS INSPECTION CHECKLIST

FACILITY FIRE PREVENTION AND EMERGENCY PREPAREDNESS INSPECTION CHECKLIST FACILITY FIRE PREVENTION AND EMERGENCY PREPAREDNESS INSPECTION CHECKLIST Date of Inspection: Conducted by: Location: Reviewed by: Date of Review: Comments or additional corrective action taken as a result

More information

A. The Commissioning Authority (CxA) has been contracted or will be contracted directly with the Owner for this project.

A. The Commissioning Authority (CxA) has been contracted or will be contracted directly with the Owner for this project. DIVISION 23 HEATING, VENTILATING, AND AIR CONDITIONING (HVAC) SECTION 23 08 02 PART 1 GENERAL 1.01 AUTHORITY (CxA) A. The Commissioning Authority (CxA) has been contracted or will be contracted directly

More information

Guidelines for energy efficient heating, ventilation and air conditioning (HVAC) systems

Guidelines for energy efficient heating, ventilation and air conditioning (HVAC) systems Guidelines for energy efficient heating, ventilation and air conditioning (HVAC) systems If you're a designer or a BCA, this guidance on the energy efficiency of HVAC systems in commercial buildings may

More information

Sprinkler Systems in Hospitals. Lisbon 6 November 2008

Sprinkler Systems in Hospitals. Lisbon 6 November 2008 Sprinkler Systems in Hospitals Lisbon 6 November 2008 Some Statistics from NFPA USA 1994-1998 1998 2,600 fires/year in healthcare facilities Causes of fire: Other equipment 20% Cooking equipment 18% Appliances/tools/air-conditioning

More information

MECHANICAL SYSTEMS DESIGN. Team 2010 2

MECHANICAL SYSTEMS DESIGN. Team 2010 2 MECHANICAL SYSTEMS DESIGN Andrew Bridges, Ben Hollon, Sean Kolich, Weston Arbogast, Kaitlin Page Andrew Bridges, Ben Hollon, Sean Kolich, Weston Arbogast, Kaitlin Page Team 2010 2 PRESENTATION OVERVIEW

More information

A cure for water damage in real estate

A cure for water damage in real estate A cure for water damage in real estate Presented for BC Non-Profit Housing Association by Jeff Shearman, Zurich Services Corporation 2010 Zurich Canada Focused on our customer Reduce overall risk by reducing:

More information

SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT PART 1 - GENERAL 1.1 DESCRIPTION A. The Work specified in this Section consists of designing, furnishing and installing factory-assembled

More information

EnerSmart Programs. enercase. Performance Contracting. contracting. Tired of. chasing capital for infrastructure upgrades?

EnerSmart Programs. enercase. Performance Contracting. contracting. Tired of. chasing capital for infrastructure upgrades? EnerSmart Programs enercase Tired of contracting chasing capital for infrastructure upgrades? enercase Summary Summary Hamilton Health Sciences is implementing one of the largest energy saving retrofit

More information

ANSUL. Restaurant Fire Suppression Systems ANSUL UL 300 ANSUL. LOW ph

ANSUL. Restaurant Fire Suppression Systems ANSUL UL 300 ANSUL. LOW ph Restaurant Fire Suppression Systems UL 300 LOW ph The Ansul R-102 System. State-of-the-art in restaurant fire protection. Meeting the fire protection challenge. In 1962, Ansul recognized that there was

More information

21.1 Functions, Basic Configuration, and Interfaces

21.1 Functions, Basic Configuration, and Interfaces 21 (6.2.M) Site Services Building 21.1 Functions, Basic Configuration, and Interfaces 21.1.1 Functions The primary functions performed by the site services building are to house, support, provide a suitable

More information

Boiler & Pressure Vessel Inspection discrepancies and failures

Boiler & Pressure Vessel Inspection discrepancies and failures Boiler & Pressure Vessel Inspection discrepancies and failures Water Heaters / Pressure Vessels Pressure Vessels are inspected once every three years. This requires a test of A: safety relief devices B:

More information

THE DESIGN OF BUILDING SERVICES FOR EARTHQUAKE RESISTANCE

THE DESIGN OF BUILDING SERVICES FOR EARTHQUAKE RESISTANCE THE DESIGN OF BUILDING SERVICES FOR EARTHQUAKE RESISTANCE Graeme J BEATTIE 1 SUMMARY The design of seismic restraints for building services equipment is often a matter that is overlooked because there

More information

The advice. The expertise. Wherever you are.

The advice. The expertise. Wherever you are. The advice. The expertise. Wherever you are. wherever you are A worldwide network of more than 120 specialists in the field Your engineers have elected to use the VAM Premium threads in the well architecture

More information

55-Gallon Dispenser Package

55-Gallon Dispenser Package INSTRUCTIONS-PARTS LIST Husky 515 55-Gallon ispenser Package 08666 Rev. C INSTRUCTIONS This manual contains important warnings and information. REA AN KEEP FOR REFERENCE. 100 psi (6.9 bar) Maximum Air

More information

CyberFortress Data Center at Innovation Park Infrastructure and Topology Guide. Innovation Park Charlotte. NC 28262. DRAFT V0.

CyberFortress Data Center at Innovation Park Infrastructure and Topology Guide. Innovation Park Charlotte. NC 28262. DRAFT V0. Innovation Park Charlotte. NC 28262 DRAFT V0.1 Page 2 CyberFortress Data Center at Innovation Park BECO South purchased Innovation Park in March 2010 and immediately launched a dramatic top-to-bottom $30M

More information

Trunnion-Design Ball Valves

Trunnion-Design Ball Valves Trunnion-Design Ball Valves 12" 20" (DN 300 500) Series 7150 12" (DN 300) Series 730S 12" 20" (DN 300 500) Series 7300 14" 24" (DN 350 600) Series 9150 14" 24" (DN 350 600) Series 9300 Installation, Maintenance

More information

Vehicle Fire Protection. An Ownerʼs Manual for ANSUL Fire Suppression/Detection Systems

Vehicle Fire Protection. An Ownerʼs Manual for ANSUL Fire Suppression/Detection Systems Vehicle Fire Protection An Ownerʼs Manual for ANSUL Fire Suppression/Detection Systems 002792 Off-road vehicles do have fires Statistics show that off-road vehicles burn with alarming frequency. These

More information

Datacenter Site Selection Checklist

Datacenter Site Selection Checklist Checklist Use this checklist to aid in the process of selecting a new site for the data center. When visiting potential building sites, print the checklist off and take it along to record impressions and

More information

Data Centre Infrastructure

Data Centre Infrastructure Data Centre Infrastructure LONDON DATA CENTRE Our data centre is located within the heart of Europe s centre of global finance London s Square Mile. The centre offers a combined net capacity of 1,520 m²

More information

HVAC Technologies for Building Energy Efficiency Improvements 2013 National Symposium on Market Transformation. Richard Lord Carrier Fellow

HVAC Technologies for Building Energy Efficiency Improvements 2013 National Symposium on Market Transformation. Richard Lord Carrier Fellow HVAC Technologies for Building Energy Efficiency Improvements 2013 National Symposium on Market Transformation Richard Lord Carrier Fellow HVAC Industry Challenges and Issues Ozone Deletion Global Warming

More information

10 Nuclear Power Reactors Figure 10.1

10 Nuclear Power Reactors Figure 10.1 10 Nuclear Power Reactors Figure 10.1 89 10.1 What is a Nuclear Power Station? The purpose of a power station is to generate electricity safely reliably and economically. Figure 10.1 is the schematic of

More information

About Injazat. Enterprise Cloud Services. Premier Data Center. IT Outsourcing. Learning and Development Services. Enterprise Application Services

About Injazat. Enterprise Cloud Services. Premier Data Center. IT Outsourcing. Learning and Development Services. Enterprise Application Services About Injazat Injazat Data Systems is an industry-recognized market leader in the region for Information Technology Outsourcing, Cloud and Data Center Managed Services delivered from the region s 1st Tier

More information

Recommended Practice for Software Acquisition

Recommended Practice for Software Acquisition Recommended Practice for Software Acquisition PSIG 003/2000 Objective: To develop a set of practices that may be used in the acquisition of pipeline simulation software. Pipeline Simulation Interest Goup,

More information

Fire Protection of Data Centres

Fire Protection of Data Centres Fire Protection of Data Centres With SEM-SAFE High-Pressure Water Mist System Danfoss Semco A/S Total Solution Provider of Certified Fixed Fire Fighting Systems Need a fire fighting system that: Allows

More information

BNA FEDERAL CREDIT UNION DISASTER RECOVERY PLAN

BNA FEDERAL CREDIT UNION DISASTER RECOVERY PLAN BNA FEDERAL CREDIT UNION DISASTER RECOVERY PLAN INTRODUCTION The need for a contingency plan for business interruptions is vital to the operations of the BNA Federal Credit Union. Without such a plan,

More information

ENERGY SERVICES ENVIRONMENTAL BENEFITS AND ENERGY SAVINGS

ENERGY SERVICES ENVIRONMENTAL BENEFITS AND ENERGY SAVINGS ENERGY SERVICES University of California Los Angeles reduces operating costs and air pollution with landfill gasfueled cogeneration and creative financing. ENVIRONMENTAL BENEFITS AND ENERGY SAVINGS Reduced

More information

Data Centers: Definitions, Concepts and Concerns

Data Centers: Definitions, Concepts and Concerns Data Centers: Definitions, Concepts and Concerns Arash Mousavi DCC September 2013 Agenda 1. Introduction 2. Issues in Modern Data Centers: Siemens Integrated Data Center Solutions 3. Issues in Modern Data

More information

3M Novec 1230 Fire Protection Fluid For Telecommunications and Data Center Applications. Stay

3M Novec 1230 Fire Protection Fluid For Telecommunications and Data Center Applications. Stay 3M Novec 1230 Fire Protection Fluid For Telecommunications and Data Center Applications Stay in Touch 3M Novec 1230 Fire Protection Fluid For Telecommunications and Data Center Applications Engineered

More information

Butterfly Valves PN 6/10/16 for flanged connection

Butterfly Valves PN 6/10/16 for flanged connection 4 136 ACVATIX Butterfly Valves PN 6/10/16 for flanged connection tight-closing VKF46.. VKF46..TS Grey cast iron housing EN-GJL-250 (to DN 300) nodular cast iron housing EN-GJS-400-15 (from DN 350) DN 40

More information

PLANT LOCATION AND LAYOUT

PLANT LOCATION AND LAYOUT PLANT LOCATION AND LAYOUT The Location Of The Plant Can Have A Crucial Effect On The Profitability Of A Project, And The Scope For Future Expansion. Many Factors Must Be Considered When Selecting A Suitable

More information

BLADDER SURGE CONTROL SYSTEM

BLADDER SURGE CONTROL SYSTEM PART I GENERAL 1.01 Description BLADDER SURGE CONTROL SYSTEM This specification describes the requirements for a Bladder Surge Control System. The purpose of the system is to minimize transient pressures

More information

MISSION CRITICAL FACILITIES DESIGN UPS BATTERY ROOM ENVIRONMENT CRITICAL DESIGN CONSIDERATIONS

MISSION CRITICAL FACILITIES DESIGN UPS BATTERY ROOM ENVIRONMENT CRITICAL DESIGN CONSIDERATIONS MISSION CRITICAL FACILITIES DESIGN UPS BATTERY ROOM ENVIRONMENT CRITICAL DESIGN CONSIDERATIONS Allen Wood Vice President Data Center Division Engineering Design Group INTRODUCTION It can be very effectively

More information

FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL

FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL January, 2003 Environmental Health and Safety Florida Atlantic University 777 Glades Rd. Boca Raton, FL 33431 Phone: 561-297-3129 Fax:

More information

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2

More information

Guide to good leak testing

Guide to good leak testing Page 0 Guide to good leak testing The Institute of Refrigeration, working with the Carbon Trust, brings you REAL Zero Refrigerant Emission and Loss Zero. The aim of this project is in the title zero refrigerant

More information

How To Stop A Gas Leak

How To Stop A Gas Leak Natural Gas / Propane Emergencies Probationary Firefighter Academy Properties of Natural Gas / Propane Natural Gas and Propane are gaseous fossil fuels Natural Gas is primarily Methane(CH 4 ) Propane is

More information

INSTALLING SEISMIC RESTRAINTS FOR MECHANICAL EQUIPMENT

INSTALLING SEISMIC RESTRAINTS FOR MECHANICAL EQUIPMENT VISCMA 412/August 2014 INSTALLING SEISMIC RESTRAINTS FOR MECHANICAL EQUIPMENT August 2014 Developed originally by the Vibration Isolation and Seismic Control Manufacturers Association under a cooperative

More information

VAD. Variable Area Desuperheaters

VAD. Variable Area Desuperheaters Desuperheater overview Steam used in process plants can be superheated, that is, heated to a temperature above saturation. The excess of temperature above its saturation is called 'superheat'. Desuperheated

More information

Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank

Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank This specification describes requirements for a Diesel Fuel Day Tank System consisting of one or more fuel tanks, an Electronic

More information

INDOOR COILS. RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

INDOOR COILS. RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES FORM NO. C11-211 REV. 7 Supersedes Form No. C11-211 Rev. 6 INDOOR COILS RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES AIRFLOW CAPACITIES 600-1,900 CFM

More information

Cased/Uncased Coils For Gas And Oil Furnaces

Cased/Uncased Coils For Gas And Oil Furnaces Indoor Coils Cased/Uncased Coils For Gas And Oil Furnaces RCFL- Series featuring Industry Standard R-410A Refrigerant Airflow Capacity 600-1,900 CFM [283-897 L/s] Rheem Indoor Coils are designed for use

More information

IT@Intel. Thermal Storage System Provides Emergency Data Center Cooling

IT@Intel. Thermal Storage System Provides Emergency Data Center Cooling White Paper Intel Information Technology Computer Manufacturing Thermal Management Thermal Storage System Provides Emergency Data Center Cooling Intel IT implemented a low-cost thermal storage system that

More information

Mechanical Systems Proposal revised

Mechanical Systems Proposal revised Mechanical Systems Proposal revised Prepared for: Dr. William Bahnfleth, Professor The Pennsylvania State University, Department of Architectural Engineering Prepared by: Chris Nicolais Mechanical Option

More information

1805 Series Relief Valves

1805 Series Relief Valves October 2011 1805 Series Relief Valves P1026 1805G Type 1805-2 Type 1805-4 Figure 1. Typical 1805 Relief Valves Introduction The 1805 Series relief valves are designed for use in farm tap applications

More information

FIRE-FIGHTING DESIGN BRIEF REPORT

FIRE-FIGHTING DESIGN BRIEF REPORT P a g e 1 SECTION 04 (Doc.No.A/DBR 001) FIRE-FIGHTING DESIGN BRIEF REPORT P a g e 2 1.0 SCOPE 2.0 STANDARDS AND CODES 3.0 TYPES OF SYSTEM PROPOSED 4.0 FIRE HYDRANT SYSTEM 5.0 AUTOMATIC SPRINKLER SYSTEM

More information

Respecting the environment

Respecting the environment MAIN FEATURE CHAPTER I RESEARCH WITH AN EYE ON THE FUTURE Respecting the environment Low power losses and a lesser visual impact on the landscape make Gas-Insulated Lines (GIL) a very environmentally friendly

More information

HEATING, VENTILATION & AIR CONDITIONING

HEATING, VENTILATION & AIR CONDITIONING HEATING, VENTILATION & AIR CONDITIONING as part of the Energy Efficiency Information Grants Program Heating and cooling can account for approximately 23 % of energy use in pubs and hotels 1. Reducing heating

More information

Flamco. Flexcon M. Installation and operating instructions. 2002 Flamco 18501067

Flamco. Flexcon M. Installation and operating instructions. 2002 Flamco 18501067 Flexcon M E Installation and operating instructions 2002 Flamco 1801067 Flamco b.v. P.O. Box 11 2800 AC Gouda - Holland Industriestraat 6 2802 AC Gouda - Holland Tel.: +31(0)182 91800 Fax: +31(0)182 227

More information