SHIP SECURITY ALERT SYSTEM (SSAS)

Size: px
Start display at page:

Download "SHIP SECURITY ALERT SYSTEM (SSAS)"

Transcription

1 SHIP SECURITY ALERT SYSTEM (SSAS)

2 Your Local Agent/Dealer 9- Ashihara-cho, Nishinomiya, Japan Telephone : fax : All rights reserved. Printed in Japan FIRST EDITION : MAY. 00 ( DAMI PUB.No. OME- ) IC-07 * * * * * * *OMEA00* *OMEA00* * O M E A 0 0 *

3 TABLE OF CONTENTS SYSTEM CONFIGURATION.... OVERVIEW OF SSAS.... INSTALLATION.... Mounting..... Junction box (for FELCOM )..... SSAS alert unit Wiring Junction box (for FELCOM ) SSAS alert unit Initial Settings.... OPERATION.... Operation Mode..... Changing the password..... SSAS manager mode.... Setting SSAS Report Destination and Message Contents.... Transmitting SSAS Report Testing the Button...9. SSAS Report Test... OUTLINE DRAWING...D- INTERCONNECTION DIAGRAM...S-

4 SYSTEM CONFIGURATION Regulations require at least two SSAS alert units. FELCOM ANTENNA UNIT IC- DGPS 00//0/0 VAC φ, 0/0 Hz / VDC AC-DC Power Supply PR-0-CE* TERMINAL UNIT IC- GPS receiver OP- EGC Printer PP-0 Personal Computer (PC/AT compatible) Shipboard LAN (Ethernet) VDC Printer VDC Printer PP-0 CATEGORY OF UNITS Unit Terminal Unit Antenna Unit Other Units Mini Keyboard Distress Message Controller DMC- OR SSAS Alert Unit SSAS Alert Unit IC-07 IC-07 (Max. units) Category Protected from weather Exposed to weather Protected from weather JUTION BOX IC- * Any AC-DC power supply fulfilling requirements of IEC 09 may be used. Distress Alert/ Received Call Unit IC-0 Alarm Unit IC-0 Navigator : Standard Supply : Option : Local Supply

5 FELCOM ANTENNA UNIT IC- 00//0/0 VAC φ, 0/0 Hz - VDC COMMUNICATION UNIT IC- (with internal GPS receiver) * Any AC-DC power supply fulfilling requirements of IEC 09 may be used. AC-DC Power Supply PR-0-CE* FURUNO O POWER I INMARSAT MINI-C MOBILE EARTH STATION POWER LOGIN TX JUTION BOX IC- SSAS ALERT UNIT IC-07 ERROR PRINTER PERSONAL COMPUTER (PC/AT compatible) : Standard : Option : Local Supply : SSAS only CATEGORY OF UNITS Antenna Unit Exposed to Weather Communication Unit Protected from Weather Other Units Protected from Weather SSAS ALERT UNIT IC-07 (Max. units)

6 . OVERVIEW OF SSAS The IC-07 SSAS (Ship Security Alert System) Alert Unit connects to the Inmarsat-C MES FELCOM or the Inmarsat Mini-C FELCOM for the purpose of alerting specified addresses (for example, your ship s company) that your ship is under attack by intruders. The SOLAS Resolution XI-/ requires vessels of 00 GT or more constructed before 0 July 00 to install an SSAS. When your ship is under attack an SSAS report, which contains your ship s name, MMSI No., position, etc. is sent to up to five locations, specified by the ship s captain or authorized personnel. No audible or visible alarm is generated while the SSAS report is being transmitted, to prevent discovery of the report by the intruders. The SSAS is protected with a password to prevent unauthorized setting or testing of it by other than the ship s captain or authorized personnel. Inmarsat System Ship Name, MMSI No., Ship Position, etc. Ship Headquarters Ship s Company, Management Company

7 SSAS operation flow. Open the cover of the button and then press the button. (This is a latch-type button; hit and release to activate the button.). If addresses have been preset, the SSAS report is sent to one address 0 seconds after the button is activated. (Max. addresses) (You may cancel transmission of the SSAS report by pressing the button again within 0 seconds of the initial press.). An LES sends acknowledgement to your ship.. Steps - and are repeated in case of multiple addressees.. Continuous transmission of the SSAS report begins. (The interval at which to transmit the SSAS report to each address can be specified. The SSAS report is continuously transmitted while the button is ON, at the interval selected.). To stop transmission, press the button again to deactivate it. (This is only possible in the SSAS manager mode. See paragraph..)

8 . INSTALLATION. Mounting.. Junction box (for FELCOM ) The junction box IC- is required when installing the SSAS on the FELCOM ; it is already installed on the FELCOM. Separate the junction box from a magnetic compass by the distances shown below to prevent deviation to a magnetic compass. Standard compass:.0 m Steering compass: 0.7 m. Remove four screws from the unit to separate the cover from the unit.. Fix the unit to the mounting location with four self-tapping screws (x, supplied).. Connect the cables appropriately referring to paragraph... 0 ±0. 70 ±0. Junction box IC- The junction box is connected to the communication unit with a meter cable, with D-sub connector (at the communication unit). Therefore, locate the junction box within two meters of the communication unit.

9 .. SSAS alert unit Separate the junction box from the SSAS alert unit by the distances shown below to prevent deviation to a magnetic compass. Standard compass: 0.70 m Steering compass: 0. m Locate the SSAS alert unit where it cannot be found by intruders. The location should be known only by ship s captain and authorized personnel. Bulkhead mounting. Remove four screws from the unit to separate the bottom chassis from the top cover.. Fix the unit to the mounting location with four self-tapping screws (supplied).. The cable can be lead in from the bottom or the rear panel. For rear panel entrance, change the clamp orientation as follows: a) Unfasten three screws to remove the cable clamp. b) Turn the clamp 90 degrees. c) Refasten the clamp with three screws unfastened at step a) to fix the clamp. Unfasten three screws. Clamp Rotate Fasten three screws.. Run the cable thru one of the cable entrances and connect it to terminal board. 7

10 . Attach the switch cover as shown below. Note that the cover may also be rotated 80 degrees. Press here and hold down for five seconds. Switch cover Flush mounting The optional flush mount kit OP-8 (Code No ) is required. Name Type Code No. Qty Remarks Fixture Pan head screw Mx Self-tapping screw x Cut out the mounting position referring to the outline drawings at the back of this manual.. Fix the unit to the fixture with four pan head screws (supplied).. Fasten the fixture with the unit to the mounting location with four self-tapping screws (supplied).. Attach switch cover as shown above. 8

11 . Wiring.. Junction box (for FELCOM ) Use the junction box IC- to connect the SSAS alert unit to the FELCOM. Unfasten four screws to remove the cover to connect cables to terminal board. For detailed wiring information see the interconnection diagram. For connection, use the JIS cable TTYCS- (or equivalent, see next page for sectional view of this cable) or the CO-SPEVV-SB-C 0.xP. When using the CO-SPEVV-SB-C 0.xP cable, replace the cable clamp with the cable clamp , supplied with the junction box. Communication Unit Cable clamp Terminal board Cover Cable clamp (top) Vcc TD/RD-A TD/RD-B TD-A(NAV) 7 TD-B(NAV) 8 RD-A(NAV) 9 RD-B(NAV) 0 DMC OUT-H DMC OUT-C DMC IN-H DMC IN-C DMC CTR Cable clamp (bottom) IC-0/0 Core 7 mm Procedure. Insert driver from direction.. Tilt slightly toward.. Insert cable core to. S0 Fold back braided shield onto sheath and fix by cable clamp. Note : Do not insert the cable too deeply, to prevent pinching the sheath. Note : Pull each cable slightly to confirm that they are in their holes securely. mm 90mm 7mm Junction box IC- 9

12 .. SSAS alert unit Three SSAS alert units can be connected in series to the Junction Box IC-. Use the terminals on the SSAS ALERT Board P09 commonly and two connector entrances. To differentiate between units in case of multiple unit installation, change jumper block settings as shown below, in accordance with how many units are installed. Jumper settings for two IC-07 Jumper settings for three IC-07 Jumper Unit No. unit* No. unit *: Default Jumper Unit No. unit* No. unit* No. unit JP No Yes setting JP No No Yes JP Yes No JP Yes Yes No No. unit: Unit with two cables connnected to it. No. unit: Unit with one cable connnected to it. No. and No. units: Units with two cables connnected to them. No. unit: Unit with one cable connnected to it. Two IC-07: No. Three IC-07: No. Two IC-07: No. Three IC-07: No. and No. P09 JP JP P09 JP JP Crimp-on lug to use : FV.-, red : Not used. : FV.-, red : FV.-, red : FV.-, red : Shield (FV-, blue) IC-07 IC-07 Cable Fabrication Clamp for cable CO-SPEVV-SB-C 0.xP Clamp for cable TTYCS- or equivalent Twist the shield. CO-SPEVV-SB-C 0.XP or TTYCS- Cut unused cables. φ =. mm mm 0 mm 0 mm Shield Conductor S = 0.7 mm φ =. mm Sectional view of cable TTYCS- Armor Sheath Wiring inside the SSAS alert unit 0

13 . Initial Settings Set up the SSAS as follows:. FELCOM : Press [F8], [F] to show the System Setup menu. FELCOM : Press [F8], [F] to show the System Setup menu.. Press [ ] to choose Command Window and then press the [Enter] key. RFCOPU *** [ Main Menu ]. Remote Box Setup. Internal GPS Setup Enter JOB No. : Command Window. Type furunoservice (without quotation marks) in the Enter JOB No. field and then press the [Enter] key. The prompt PASSWORD appears.. Enter password (see Service Manual) then press the [Enter] key. Then, the item Main Menu is displayed in reverse video.. Press [], [Enter], [], [Enter]. One of the following windows appears. [ DMC ]. SSAS. DMC. OFF E: Exit Enter No.: FELCOM [ SSAS ]. ON. OFF E: Exit Enter No.: FELCOM. Press [], [Enter]. This enables the SSAS functions. 7. Press the [Esc] key several times to close the menu. Note: Test the SSAS button and SSAS report for proper operation, referring to paragraphs. and., respectively.

14 . OPERATION. Operation Mode There are two menu operating modes: Normal mode: Menus other than SSAS-related menus are displayed. SSAS manager mode: The mode is activated by the password entered by the ship s captain or authorized personnel. The indication SSAS Manager Mode is shown flashing at the top of the screen when this mode is activated. All SSAS-related menus are available. Transmission of the SSAS report may be cancelled in this mode. The equipment starts up in the normal mode, regardless of the mode in use when the power is turned off... Changing the password The default password is ship security alert. Ship s captain or authorized personnel may change the password as follows:. FELCOM : Press [F8], [F] to show the System Setup menu. FELCOM : Press [F8], [F] to show the System Setup menu.. Press [ ] to choose Command Window and then press the [Enter] key. RFCOPU *** [ Main Menu ]. Remote Box Setup. Internal GPS Setup Enter JOB No. : Command Window. On the Enter JOB No. field, type ssas password (without quotation marks) and then press the [Enter] key. The prompt OLD PASSWORD appears.. Type your current password and then press the [Enter] key. The prompt NEW PASSWORD appears.. Enter new password, using at least six characters, and then press the [Enter] key. The prompt RETYPE NEW PASSWORD appears. Note: If less than six characters are entered for the password, the message Please use a longer password. appears. Enter a longer password.. Enter new password again and then press the [Enter] key. The message Password changed appears. 7. Press the [Esc] key several times to close the menu. Note: The SSAS manager mode cannot be unlocked without the proper password.

15 .. SSAS manager mode All SSAS-related settings are set in the SSAS manager mode. Do the following to access this mode.. FELCOM : Press [F8], [F] to show the System Setup menu. FELCOM : Press [F8], [F] to show the System Setup menu.. Press [ ] to choose Command Window and then press the [Enter] key. Command Window RFCOPU *** [ Main Menu ]. Remote Box Setup. Internal GPS Setup Enter JOB No. :. On the Enter JOB No. field, type ssas manager (without the quotation marks) and then press the [Enter] key.. Type password and then press the [Enter] key. The window below appears; you are now in the SSAS manager mode :7 (UTC) SSAS Manager Mode enabled. CAUTION <Press ESC key to continue>. Press the [Esc] key several times to close the menu. This enables the SSAS manager mode, which allows you to execute the procedure in paragraph..

16 . Setting SSAS Report Destination and Message Contents When the SSAS is activated, the SSAS report is sent according to the addresses (max. ) and message content set with SSAS Report SSAS Report on the SSAS Report menu. Note : The destination and message content of an SSAS report varies according to Administration. Therefore, set them as requested by ship s authorities. For information other than ship s name, MMSI no. and IMN no., set it manually with Other Inf. Note : The equipment must be in the SSAS manager mode to execute this procedure. See paragraph.... Press the [F] to open the Reports menu. Reports. Data Report. Message Report. Data Network ID. SSAS Report. Press the [] key to shown the SSAS Report menu. SSAS Report. SSAS Report. SSAS Report. SSAS Report. SSAS Report. SSAS Report. Message Contents. Press [], [], [], [] or [] key as appropriate. (When the button is tested, a test report is sent to the address specified for the youngest SSAS report number. Therefore, set the address which is to receive the test report set for the youngest SSAS report number.) SSAS Report Status Station Name Destination Type Prefix Code Country/Ocean Code Station ID Modem Type Address Subject LES ID Report Interval ON TELEX 0:00 (hh: mm). Press the [ ] key to choose Station Name and then press the [Enter] key.. Press the [ ] or [ ] key to choose appropriate station and then press the [Enter] key. You may sort the list by group name, station name or communication type as follows: Group name: Each press of [Ctrl] + [G] sorts the list by group name, ascending or descending order. Station name: Each press of [Ctrl] + [N] sorts the list by station name, in ascending or descending order. Comm. type: Each press of [Ctrl] + [T] sorts the list by communication type, in ascending or descending order.

17 . Press the [ ] key to choose LES ID and then press the [Enter] key. 7. Press the [ ] or [ ] key to choose LES and then press the [Enter] key. 8. Press the [ ] key to choose Report Interval and then press the [Enter] key. 9. Enter time interval (00:0-99:9) to transmit the SSAS report and then press the [Enter] key. Note: After the SSAS report is transmitted and the button remains ON ( ), the SSAS report is transmitted at the interval set here. 0. Press the [Esc] key to open the Update window. Status Station Name Destination Type Prefix Code Country/Ocean Code Station ID Modem Type Address Subject LES ID Report Interval SSAS Report ON TELEX 0:00 (hh: mm) Yes Update No. Yes is selected; press the [Enter] key to close the SSAS report window.. Press the [] key to display the SSAS Message Contents menu. Vessel Name : MMSI : IMN : Other Inf. : LAT: LON: Time: COURSE: SPEED: Time: SSAS Message Contents _ :. N :. E 0/0/00 0::8 (UTC) 07 deg 00 kt 0/0/00 0::8 (UTC). Press the [Enter] key to open the Vessel Name window.. Enter vessel s name and then press the [Enter] key.. Press the [ ] key to choose MMSI and then press the [Enter] key.. Enter MMSI number and then press the [Enter] key. 7. Press the [ ] key to choose IMN and then press the [Enter] key. 8. Enter IMN and then press the [Enter] key. 9. Press the [ ] key to choose Other Inf. and then press the [Enter] key 0. Enter appropriate message (three lines) and then press the [Enter] key. Note: To shift between lines, use the [ ] or [ ] key.. Press the [Esc] key to display the Update window.. Yes is selected; press the [Enter] key to close the SSAS Message Contents menu.

18 . Press the [Esc] key twice to return to the standby display. Note : To delete entered subscriber s data, choose Remove from Status. Note : SSAS report settings may be saved to a floppy disk for backup. FELCOM : [F8], [9], [] to show the Save/Load window. FELCOM : [F8], [8], [] to show the Save/Load window. Save to FD. ALL. Station List. LES List. Service List. SSAS Report*. Other Load from FD. ALL. Station List. LES List. Service List. SSAS Report*. Other *: Availlable only in SSAS manager mode (".SSAS Report" is added in the SSAS manager mode and item numbers are shifted.) Note : To confirm the settings, follow paragraph..

19 . Transmitting SSAS Report In the normal mode, the SSAS report is sent 0 seconds after the button on the SSAS is pressed. The SSAS repeatedly transmits the report even if the button is pushed off ( ). Repeated transmission can only be stopped from the SSAS manager mode.. Open the cover of the SSAS alert button. Cover. Push the button. The button is a latch-type button; hit and release the button to activate ( ) the SSAS unit.. The SSAS report is transmitted 0 seconds after the button is pushed in ( ). Below are the contents of the SSAS report SSAS ALERT MESSAGE Vessel Name: Queen Elizabeth MMSI: 0000 IMN: Help me! LAT: :.N LON: :.E Time: 0/0/00 0::8 (UTC) COURSE: 07 deg SPEED: 00 kt Time: 0/0/00 0::8 (UTC) Ship s Name MMSI No. IMN No. Desired message Own ship postion in latitude Own ship position in longitude Time of position data Course Speed Time of course and speed data Note: If you accidentally push the button in, push it again within 0 seconds to cancel the report. The button pops out ( ) and the report is not transmitted. When this is done, the message INF: SSAS UNIT activation has been canceled. appears on the display. Additionally, for the FELCOM, the POWER lamp on the communication unit flashes 0 seconds.. An LES sends acknowledgement to your ship.. For multiple destinations, steps and are repeated.. The SSAS report is transmitted repeatedly while the button remains pushed in ( ). 7. To stop transmission, push the button again to pop it out ( ). (SSAS manager mode only.) 7

20 Note : You may cancel repeated transmission from either operating mode by pushing the button OFF ON OFF ON OFF. You must allow no more than three seconds to elapse before pushing the button again. If more than three seconds elapses, repeat the procedure. When transmission is stopped, the message INF: SSAS UNIT activation has been cancelled. appears and, on the FELCOM only, the POWER lamp on the communication unit flashes approx. 0 seconds. Note : If transmission is not canceled with the button and the power is turned off, the equipment resumes repeated transmission when powered again. 8

21 . Testing the Button The SSAS buttons can be tested as below. Note : An actual SSAS report cannot be transmitted during the testing. Note : The equipment must be in the SSAS manager mode to conduct the test. FELCOM. Press the [F7] key to display the Options menu.. Press the [7] key ([] key when the FELCOM functions as an EGC receiver) to display the Test menu.. Press the [] key. Test. PV Test. PV Test Result. Diagnostic Test. Distress/SSAS Button Test Options. Login.. Logout PV Test Test Distress/SSAS Button Test.. Abort PV Test Result.. Select Self Test S Start.. Ocean Distress Region Alarm Button Test. Test Yes No. Press the [Enter] key to start the test. Options. Login Test.. Logout PV Test Distress/SSAS Button Test.. Abort PV Test Result.. Select Self Distress/SSAS Test S buttons are under test mode... Ocean Distress Region Alarm Press Button any key Test CAUTION to escape. INF: Distress/SSAS. Test Buttons entered into TEST MODE. <Press ESC key to continue> The display shows the message (in red) Distress/SSAS buttons are under test. Cancel the test mode if a real distress/ssas needs to sent. appears.. Open the button cover on the No. SSAS.. Push the button in ( ). The CAUTION window displays the message SSAS UNIT works correctly. appears if the unit is functioning properly. Note: 0 seconds after step, the SSAS test report is automatically sent. If you do not need to send the SSAS report, go to step 8 within 0 seconds. 7. The SSAS test report is automatically sent once to the address specified for the youngest SSAS report number (-). 8. Turn the button of the No. SSAS off ( ). Note: To test the No. and No. SSAS repeat steps -8. 9

22 9. To escape from the test, press the [Esc] key twice on the terminal unit. The test mode is stopped and the message shown below appears to notify you that normal operation has been restored. CAUTION INF: Distress/SSAS Buttons returned to NORMAL OPERATION. <Press ESC key to continue> Further, because the button remains pushed in ( ), the message Please return the SSAS button into OFF-STATE. appears. 0. Push the button again to pop it out ( ).. Close the button cover.. Press the [Esc] key three times to return to the standby display. Note: If the button is left pushed in ( ) when the terminal unit is turned on, the equipment displays Please return the SSAS button into OFF-STATE. Push the button again to turn off ( ) the button. FELCOM (no PC). Turn off the communication unit.. Push the button of the No. SSAS to turn it on ( ).. Turn on the communication unit.. 0 seconds later the POWER, LOGIN and TX LEDs on the communication unit start flashing together if the button is judged to be ON. Note: An SSAS test report is automatically transmitted 0 seconds after all LEDs start flashing at step. If you do not need to send the test report, skip to step seconds after LEDs start flashing the SSAS test report is sent once to the address specified for the youngest SSAS report number (-). At this time the LEDs flash rapidly. If transmission was successful the LEDs mentioned in step flash slowly. If transmission failed, only the ERROR LED flashes (rapidly).. Push the button of the No. SSAS to turn it off ( ). The LEDs light in order of POWER, LOGIN, TX, POWER, LOGIN, TX. 7. Push the button of the No. SSAS to turn it on ( ) seconds later the POWER, LOGIN and TX LEDs on the communication unit start flashing together if the button is judged to be ON. Note: An SSAS test report is automatically transmitted 0 seconds after all LEDs start flashing. If you do not need to send the test report, skip to step seconds after the above-mentioned LEDs start flashing the SSAS test report is sent. 0. Push the button of the No. SSAS to turn it off ( ). Note: If there is a No. SSAS, test it by following steps Finally, turn the communication unit off and then on again. Note : After completing the testing, be sure to turn off all SSAS units. Note : The normal mode is automatically restored after 0 minutes elapses in the test mode. 0

23 Note : The ERROR LED flashes every two seconds if the button of an SSAS stays on for more than 0 seconds. It also flashes when the equipment switches to the normal mode (see Note ). Turn off the button to stop the LED from flashing. FELCOM (by PC). Press the [F7] key to display the Options menu.. Press the [7] key ([] key when the FELCOM functions as an EGC receiver) to display the Test menu. Test. PV Test. PV Test Result. Diagnostic Test. SSAS Button Test. Press the [] key. Options. Login Test.. Logout PV Test SSAS Button Test.. Abort PV Test Result.. Select Self Test S.. Ocean Distress Region Alarm Button Test. Test Yes Start No. Press the [Enter] key to start the test. Options. Login Test.. Logout PV Test SSAS Button Test.. Abort PV Test Result.. Select Self Test S SSAS buttons are under test mode... Ocean Distress Region Alarm Press Button any key Test CAUTION to escape. INF: SSAS. Buttons Test entered into TEST MODE. <Press ESC key to continue> The display shows the message (in red) SSAS buttons are under test. Cancel the test mode if a real SSAS alert needs to sent. appears.. Open the button cover on the No. SSAS.. Push the button in (ON). The CAUTION window displays the message SSAS UNIT works correctly. appears if the unit is functioning properly. Note: 0 seconds after step, the SSAS test report is automatically sent. If you do not need to send the test report, go to step 8 within 0 seconds. 7. The SSAS test report is automatically sent once to the address specified for the youngest SSAS report number (-). 8. Turn the button of the No. SSAS off ( ). Note: To test the No. and No. SSAS repeat steps -8.

24 9. To escape from the test, press the [Esc] key twice on the terminal unit. The test mode is stopped and the message shown below appears to notify you that normal operation has been restored. CAUTION INF: SSAS Buttons returned to NORMAL OPERATION. <Press ESC key to continue> Further, because the button remains pushed in ( ), the message Please return the SSAS button into OFF-STATE. appears. 0. Push the button again to pop it out ( ).. Close the button cover.. Press the [Esc] key three times to return to the standby display. Note: If the button is left pushed in ( ) when the communication unit is turned on, the equipment will go into the test mode if the SSAS is not transmitting repeatedly. To return to the standby display, push the button again to pop it out ( ) and then turn the communication unit off and on again.

25 . SSAS Report Test You can test for successful transmission of the SSAS report to the address you specify, without using the button. The test report message states!!! Test Call!!! to alert the receiver of the message that it is a test call.. Press the [F] key to open the Reports menu.. Press the [] key to choose the SSAS Report menu.. Press the [], [], [], [] or [] key as appropriate, and the SSAS report setting menu appears.. Set destination where to transmit the test.. Press the [ ] key to choose Status and then press the [Enter] key.. Press the [ ] key to choose TEST and then press the [Enter] key. 7. Press the [Esc] key to show the Update window. 8. Yes is selected; press the [Enter] key. The test report is transmitted. After it is transmitted, Status is automatically set to ON. 9. Press the [Esc] key twice to return to the standby display.

26

27

28

29 A B C D VDC - VDC 00-/ 0-0 VAC φ,0/0hz VDC RW-77 0.m アンテナユニット ANTENNA UNIT IC- 船 内 LAN (HUB) パソコンなど LAN(HUB) OR PC, ETC. VCTF-0.7xC m,φ.9 (S008) * DPYC-. φ.8 * DPYC- φ.9 TPAFB0.NJ FBA-DFB,0.m キーボード KEYBOARD BTC-00C PS/ VDC RHBPG-S J アカ RED +V クロ BLK シロ WHT 0V + - MJ-ASPF008,m,φ AC_IN VDC INPUT ケーブル:コネクタ 選 択 CABLE: CONNECTOR, SELECTED D-SFA-CV,00m,φ.: N-P-0DSFA 8D-FB-CV,0m,φ.0: N-P-8DFB TPFBAW-DFBB,0m,φ7. * Ethernet CABLE PC: CROSS CABLE HUB: STRAIGHT CABLE プリンタ PRINTER PP-0 VDC + * OUTPUT - PR-0-CE AC/DC 電 源 ユニット AC/DC POWER SUPPLY UNIT PE,IV-.SQ. 保 護 アース 注 記 *) 工 場 にて 取 付 済 み *) 造 船 所 手 配 *)オプション *)コネクタクランプでアースに 落 とす *)ユーザー 手 配 *)TB 基 板 (P0)が 必 要 *7) 台 または 台 接 続 可 能 終 端 のIC-07はジャンパー 設 定 の 変 更 が 必 要 * * 7-0 * TP-NJ RJ- P P 7JE-0-0(D8C) * S08,m,φ8 FUSE A(V) 7A(V) シロ WHT クロ BLK * MJ-ASPFD 7 8 ANT B0 KEYBOARD KDAT +V KCLK LAN E_TD_P E_TD-N E_RD_P E_RD_N PRINTER B0 ターミナルユニット TERMINAL UNIT IC- P008A P009 -VDC DC(+) DC(-) B0 P0 DGPS JUTION Vcc(ALM) TD/RD-A TD/RD-B TD-A TD-B RD-A RD-B DMC_OUT-H DMC_OUT-C DMC_CHECK DMC_IN-C DMC_CTRL DTE D-sub9P * D-sub9P 7JE-7-0,m,φ8 CO-0.xP,m MAX. TXD RXD CO-0.xP * 9 * m MAX. * 銅 板 W=0 COPPER STRAP ,.m B PLAG D-subP * * CO-AX (0Ω) S0,m,φ9. チャ BRN ミドリ GRN アカ RED ハイ GRY ダイ ORG アオ BLU キ YEL クロ BLK モモ PNK アオ/アカ BLU/RED シロ WHT タ イ/シロ ORG/WHT ミト リ/シロ GRN/WHT ムラサキ PPL FM-P DGPSデコーダー DGPS DECODER RXD TXD 0V I/F BOX OP- * 接 続 箱 JUTION BOX IC DMC_OUT-H DMC_OUT-C DMC_IN-H DMC_IN-C DMC_CTR CO-0.xP パソコン RXD TXD PC * DTR S. DSR RTS CTS * FM-7P CO-0.xP MAX.00m 7 * TTYCS-,φ. 航 法 装 置 NAV EQUIPMENT TXD-H TXD-C * TTYCS-,φ. OR CO-0.xP 合 計 : 最 大 00m TOTAL:MAX.00m * TTYCS-,φ. FM-7P FM-7P P P 7 7 P EGCプリンタ RXD EGC PRINTER TXD PP-0 0V * (+) (-) RXD-H TXD-H FG TXD-C RXD-C +9V P P P P P P P アラームユニットIC-0 ALARM UNIT 保 安 警 報 発 呼 器 SSAS ALERT UNIT IC-07 (No.) EGCプリンタ EGC PRINTER PP-0 * * (+) (-) P0B VCC TD/RD-A TD/RD-B FG 遭 難 警 報 器 IC-0 DISTRESS ALERT/ RECEIVED CALL UNIT P0A VCC TD/RD-A TD/RD-B FG TB IC-07 (No.) * *7 TB * *7 SSAS_OUT-H SSAS_OUT-H SSAS_CHECK SSAS_CHECK SSAS_IN-C SSAS_CTRL SSAS_IN-C SSAS_CTRL 遭 難 警 報 装 置 DMC- DISTRESS MESSAGE CONTROLLER TB DIST_IN-H DIST_IN-C DIST_OUT-H DIST_OUT-C DIST_CTR 08S07,m 08S S07,m 08S0087 保 安 警 報 発 呼 器 SSAS ALERT UNIT VDC VDC 保 安 警 報 発 呼 器 SSAS ALERT UNIT IC-07 (No.) TB * *7 SSAS_OUT-H SSAS_CHECK SSAS_IN-C SSAS_CTRL NOTE *. FITTED AT FACTORY. *. SHIPYARD SUPPLY. *. OPTION. *. GROUND THRU CONNECTOR CLAMP. *. USER SUPPLY. *. TB BOARD (P0) REQUIRED. *7. OR SETS CAN BE CONNECTED. CHANGE JUMPER SETTING IN LAST IC-07. CO-0.xP: CO-SPEVV-SB-C 0.xP,φ0. CO-0.xP: CO-SPEVV-SB-C 0.xP,φ. DRAWN Apr. '0 CHECKED K.MIYAZAWA TAKAHASHI.T APPROVED SCALE MASS kg DWG No. C-C0- E TITLE 名 称 FELCOM インマルサットC 船 舶 地 球 局 相 互 結 線 図 NAME INMARSAT-C MES INTERCONNECTION DIAGRAM FURUNO ELECTRIC CO., LTD.

30 A B C アンテナユニット ANTENNA UNIT IC- RW m TPAFB0.NJ FBA-DFB,0.m ケーブル:コネクタ 選 択 CABLE: CONNECTOR, SELECTED D-SFA-CV,00m,φ.: N-P-0DSFA 8D-FB-CV,0m,φ.0: N-P-8DFB TPFBAW-DFBB,0m,φ7. TP8AW-RG8,m,φ.0 - VDC P--.(P),.m,φ7. アカ RED クロ BLK * FM-CFP 00-/ 0-0 VAC φ,0/0hz VDC * DPYC-. φ.8 * DPYC- φ AC_IN VDC INPUT VDC OUTPUT * PR-0-CE AC/DC 電 源 ユニット AC/DC POWER SUPPLY UNIT + - 注 記 *) 工 場 にて 取 付 済 み *) 造 船 所 手 配 *)オプション *)コネクタクランプでアースに 落 とす *)ユーザー 手 配 *)SSAS 仕 様 *7) 最 大 台 まで 接 続 可 能 終 端 のIC-07はジャンパー 設 定 の 変 更 が 必 要 NOTE *. FITTED AT FACTORY. *. SHIPYARD SUPPLY. *. OPTION. *. GROUND THRU CONNECTOR CLAMP. *. USER SUPPLY. *. SSAS SPECIFICATION. *7. MAX SETS CAN BE CONNECTED. CHANGE JUMPER SETTING IN LAST IC-07. PE,IV-.SQ. 保 護 アース ANT -VDC DC(+) DC(-) DRAWN Apr. '0 CHECKED APPROVED SCALE DWG No. K.MIYAZAWA TAKAHASHI.T MASS C8-C0- D kg TITLE 名 称 NAME FELCOM インマルサットC 船 舶 地 球 局 相 互 結 線 図 INMARSAT-C MES INTERCONNECTION DIAGRAM TP-NJ FUSE V:0A V : A 通 信 制 御 ユニット COMMUNICATION UNIT IC- B0 P008B DTE TXD RXD D-sub9P 7JE-7-0,m,φ8 * D-sub9P * * パソコン PC * RXD TXD DTR S. DSR RTS CTS B0 P07 SSAS Vcc(.V) TX/RX-A TX/RX-B SSAS_OUT-H SSAS_CHECK SSAS_IN-C SSAS_CTRL D-subP * チャ ミドリ アカ ハイ ダイ アオ キ クロ モモ アオ/アカ シロ タ イ/シロ ミト リ/シロ ムラサキ S0 m,φ9. BRN GRN RED GRY ORG BLU YEL BLK PNK BLU/RED WHT ORG/WHT GRN/WHT PPL * 接 続 箱 JUTION BOX IC- * Vcc TD/RD-A TD/RD-B TD-A TD-B RD-A RD-B DMC_OUT-H DMC_OUT-C DMC_IN-H DMC_IN-C DMC_CTR P P 保 安 警 報 発 呼 器 SSAS ALERT UNIT IC-07 (No.) TB * SSAS_OUT-H SSAS_CHECK SSAS_IN-C SSAS_CTRL 保 安 警 報 発 呼 器 SSAS ALERT UNIT IC-07 (No.) TB * SSAS_OUT-H SSAS_CHECK SSAS_IN-C SSAS_CTRL W=0 銅 板 COPPER STRAP ,.m * * TTYCS-,φ. OR CO-0.xP 全 長 00m 以 下 TOTAL:00m MAX. 保 安 警 報 発 呼 器 SSAS ALERT UNIT IC-07 (No.) TB * * *7 SSAS_OUT-H SSAS_CHECK SSAS_IN-C SSAS_CTRL

INSTALLATION MANUAL NMEA DATA CONVERTER

INSTALLATION MANUAL NMEA DATA CONVERTER INSTALLATION MANUAL NMEA DATA CONVERTER Model IF-NMEA2K2 WARNING Do not install the unit where it may get wet from rain or water splash. Water in the unit can result in fire, electrical shock or damage

More information

RJ11 RS-232 Interface

RJ11 RS-232 Interface H NS TN30 RJ11 RS-232 Interface 1.0 General The back panel of the CPP-3794 provides a combination of 9 pin DB connectors and RJ11 connectors for connecting RS-232 serial cables. The 9 pin DB connector

More information

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 INSTALLATION GUIDE Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 Card Reader and Controller Model 3.5 with KIM Swipe Reader Table of Contents 1. Features..................................

More information

Application Note. Equipment Needed

Application Note. Equipment Needed Application Note Setting up a Quick Local Area Network for CRemote General Nuclear Industry Application Introduction to the fundamentals of CRemote and a standalone LAN for CANBERRA Contamination Monitors

More information

Quick Start Guide. 7000 Series 1 RU Gen 2 Data Center Switches. Arista Networks. www.aristanetworks.com DCS-7150S-64 PDOC-00019-13

Quick Start Guide. 7000 Series 1 RU Gen 2 Data Center Switches. Arista Networks. www.aristanetworks.com DCS-7150S-64 PDOC-00019-13 Quick Start Guide 7000 Series 1 RU Gen 2 Data Center Switches DCS-7048T-A DCS-7050Q-16 DCS-7050QX-32 DCS-7050S-52 DCS-7050S-64 DCS-7050T-36 DCS-7050T-52 DCS-7050T-64 DCS-7124FX DCS-7124SX DCS-7150S-24

More information

Network Video Recorder Quick Operation Guide

Network Video Recorder Quick Operation Guide Network Video Recorder Quick Operation Guide UD.6L0202B1283A01 TABLE OF CONTENTS NVR Pre-Installation... 2 NVR Installation... 2 Hard Disk Installation... 2 Front Panel... 4 Rear Panel... 5 Specifications...

More information

ISHIDA BC-3000. Scale to Scale Communications

ISHIDA BC-3000. Scale to Scale Communications ISHIDA BC-3000 Scale to Scale Communications Setup Procedure & Operating Instructions March 2006 PN 94561 Revision History Date Page Description March 2006 Initial publication August 2006 2 Added RS-232

More information

Quick Installation. A Series of Intelligent Bar Code Reader with NeuroFuzzy Decoding. Quick Installation

Quick Installation. A Series of Intelligent Bar Code Reader with NeuroFuzzy Decoding. Quick Installation Quick Installation A Series of Intelligent Bar Code Reader with NeuroFuzzy Decoding This chapter intends to get your new FuzzyScan scanner working with your existing system within minutes. General instructions

More information

32 Transferring Projects and Data

32 Transferring Projects and Data 32 Transferring Projects and Data This Chapter explains how to transfer GP-Pro EX project files to the GP and how to transfer the project files stored on the GP to your PC. Please start by reading 32.1

More information

Installation Manual BRIDGE ALARM SYSTEM BR-1000

Installation Manual BRIDGE ALARM SYSTEM BR-1000 Installation Manual BRIDGE SYSTEM BR-000 SAFETY INSTRUCTIONS...i SYSTEM CONFIGURATION...ii EQUIPMENT LISTS...iii. HOW TO INSTALL THE EQUIPMENT...-. Bridge Panel...-. Processor Unit...-. Cabin Panel, Timer

More information

RS-232/422/485, Power over Ethernet

RS-232/422/485, Power over Ethernet IP-COM-M IP-COMi-M IP-COM-M PoE IP-COMi-M PoE RS-232 RS-232/422/485 RS-232, Power over Ethernet RS-232/422/485, Power over Ethernet Edition: September 2012 The computer programs provided with the hardware

More information

HT580 User Reference Guide. Version 1.0

HT580 User Reference Guide. Version 1.0 Version 1.0 NOTICE 1. Li-Ion Battery Pack The HT580 Portable Terminal and the Li-Ion Battery Pack are packaged separately. You will have to install the Battery Pack when you receive your terminal. Please

More information

Bluetooth to Serial Adapter

Bluetooth to Serial Adapter Bluetooth to Serial Adapter Third Edition, Oct 2007 Version 3.0 771-BTS1009C3-001 Contents 1.0 Features....P.2 2.0 Package Content....P.2 3.0 Hard Drives Requirement.P.2 4.0 Specifications.P.3 5.0 Pin

More information

How To Program An Autodialer

How To Program An Autodialer GJD HYL005 GSM Autodialer Instruction Manual Please read these instructions before you start the installation Features: LCD display. Programmable 9 x 32 digit phone numbers for each trigger. 10 second

More information

ShareLink 200 Setup Guide

ShareLink 200 Setup Guide ShareLink 00 Setup Guide This guide provides instructions for installing and connecting the Extron ShareLink 00. The ShareLink USB 00 Wireless Collaboration Gateway allows anyone to present content from

More information

SecureLinx Spider Duo Quick Start Guide

SecureLinx Spider Duo Quick Start Guide SecureLinx Spider Duo Quick Start Guide SecureLinx Spider Duo Quick Start Guide SecureLinx Spider Duo QUICK START GUIDE CONTENTS Overview... 2 What s In The Box... 3 Installation and Network Settings...

More information

Error! Bookmark not defined. Error! Bookmark not defined. Error! Bookmark not defined.

Error! Bookmark not defined. Error! Bookmark not defined. Error! Bookmark not defined. Remote Lighting Kit Table of Contents Lighting Kit Overview 2 System Requirements 3 Basic Concepts of Wireless Routers and Networks 4 Basic Concepts of Network Light Bulbs 8 Planning Your Lighting Network

More information

Network Video Recorder Quick Operation Guide

Network Video Recorder Quick Operation Guide Network Video Recorder Quick Operation Guide UD.6L0202B1119A01 Thank you for purchasing our product. If there is any question or request, please do not hesitate to contact dealer. This manual is applicable

More information

Amcrest 960H DVR Quick Start Guide

Amcrest 960H DVR Quick Start Guide Amcrest 960H DVR Quick Start Guide Welcome Thank you for purchasing our Amcrest 960H DVR! This quick start guide will help you become familiar with our DVR in a very short time. Before installation and

More information

SAILOR H4122 Iridium Ship Security Alert System Operating / Installation Manual

SAILOR H4122 Iridium Ship Security Alert System Operating / Installation Manual SAILOR H4122 Iridium Ship Security Alert System Operating / Installation Manual Introduction Thank you for choosing our equipment and Congratulations on Your new Iridium Ship Security Alert System. We

More information

DVR-4TL/8TL/16TL Setup Guide

DVR-4TL/8TL/16TL Setup Guide Package Content DVR-4TL/8TL/16TL Setup Guide Inspect the DVR s packaging. Make sure that the DVR-4TL/8TL/16TL is packed properly. Remove all items from the box and make sure it contains the following items.

More information

How to read this guide

How to read this guide How to read this guide The following shows the symbols used in this Quick start guide with descriptions and examples. Symbol Description Example P oint Reference Caution [ ] This symbol explains information

More information

RACEAIR REMOTE PAGER SYSTEM

RACEAIR REMOTE PAGER SYSTEM Computech Systems, Inc. 301-884-5712 30071 Business Center Dr. Charlotte Hall, MD 20622 RACEAIR REMOTE PAGER SYSTEM TM Introduction: Computech s RaceAir Remote Competition Weather Station with the Data

More information

Network Video Recorder

Network Video Recorder Network Video Recorder XC-4CH-NVR-1TB and XC-8CH-NVR-2TB Username: admin Password: 12345 Quick Operation Guide XC-4CH-NVR-1TB and XC-8CH-NVR-2TB quick guide TABLE OF CONTENTS NVR Pre-Installation... 2

More information

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual 5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...

More information

Application/Connection Examples

Application/Connection Examples This Quick Start Guide is designed to familiarize the user with the connection and configuration of the DTS-305 DIN rail mounted single / 3 phase power & energy meter with RS-485 or TCP communications.

More information

aseries DVR04/DVR08 DIGITAL VIDEO RECORDER Quick Operations Guide

aseries DVR04/DVR08 DIGITAL VIDEO RECORDER Quick Operations Guide aseries DVR04/DVR08 DIGITAL VIDEO RECORDER Quick Operations Guide UD.7L0202B1365B01 Thank you for purchasing our product. If there is any question or request, please do not hesitate to contact dealer.

More information

WITURA CORPORATION SDN BHD

WITURA CORPORATION SDN BHD WT 1010SA Stand Alone GSM Alarm System User Manual and Installation Instructions Version: 1.2 Updated: 4 JAN 2012 WITURA CORPORATION SDN BHD Stand Alone GSM Alarm System Instruction Manual 1 Introduction:

More information

JKW-IP. IP Video Entry System. QuikStart Guide

JKW-IP. IP Video Entry System. QuikStart Guide 1210 JKW-IP IP Video Entry System QuikStart Guide This is an abbreviated instruction manual for installation purposes. Please see the JKW-IP Installation Manual and JKW-IP Operation Manual for complete

More information

Setting Up the ZigBee Ethernet Gateway

Setting Up the ZigBee Ethernet Gateway Setting Up the ZigBee Ethernet Gateway MAN-01-00030-1.4 This manual describes how to install and set up ZigBee communication between a SolarEdge device (Inverters or Safety and Monitoring Interface) and

More information

Application Note 2. Using the TCPDIAL & TCPPERM Commands to Connect Two TransPort router Serial Interfaces Over TCP/IP.

Application Note 2. Using the TCPDIAL & TCPPERM Commands to Connect Two TransPort router Serial Interfaces Over TCP/IP. Application Note 2 Using the TCPDIAL & TCPPERM Commands to Connect Two TransPort router Serial Interfaces Over TCP/IP. Reverse Telnet or Serial Terminal Server MultiTX feature UK Support March 2014 1 Contents

More information

GPS NTP Time Server for Intranet Networks DIN RAIL Version

GPS NTP Time Server for Intranet Networks DIN RAIL Version GPS NTP Time Server for Intranet Networks DIN RAIL Version Description: GPS NTP time server is very simple low cost solution for Ethernet / Intranet time synchronization. Each computer or devices with

More information

Network FAX Driver. Operation Guide

Network FAX Driver. Operation Guide Network FAX Driver Operation Guide About this Operation Guide This Operation Guide explains the settings for the Network FAX driver as well as the procedures that are required in order to use the Network

More information

ENET-710. ENET-710 - Ethernet Module ENET-710 JAN / 06 FOUNDATION

ENET-710. ENET-710 - Ethernet Module ENET-710 JAN / 06 FOUNDATION ENET-710 ENET-710 - Ethernet Module JAN / 06 ENET-710 FOUNDATION E N E T 7 1 0 ME smar www.smar.com Specifications and information are subject to change without notice. Up-to-date address information is

More information

FLEET MANAGEMENT & CAR SECURITY SYSTEM GPRS/GPS

FLEET MANAGEMENT & CAR SECURITY SYSTEM GPRS/GPS FLEET MANAGEMENT & CAR SECURITY SYSTEM FOR PROVIDERS AND CUSTOMERS The Tracker Server Communication Program for data collection The Tracker Client Map Program intended for dispatching desks The GSM/GPRS

More information

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS MAKING MODERN LIVING POSSIBLE AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS How to Use This Guide Read this Guide completely as you install and start up your new AK-SC 255 controller.

More information

B890 4G LTE Smart Hub Getting Started Guide

B890 4G LTE Smart Hub Getting Started Guide B890 4G LTE Smart Hub Getting Started Guide HUAWEI TECHNOLOGIES CO., LTD. Thank You for Purchasing the B890 4G LTE Smart Hub! Before You Begin What s in the Box : 1. B890 4G LTE Smart Hub 2. Power adapter

More information

LAN / WAN Connection Of Instruments with Serial Interface By Using a Terminal Server

LAN / WAN Connection Of Instruments with Serial Interface By Using a Terminal Server Products: EFA with EFA Scan, DVRM and DVMD with Realtime Monitor or Stream Explorer DVMD-B1 LAN / WAN Connection Of Instruments with Serial Interface By Using a Terminal Server Remote control of test and

More information

POS UNITS. Installation and user guide. Count, video recording and POS control unit ENGLISH

POS UNITS. Installation and user guide. Count, video recording and POS control unit ENGLISH ENGLISH POS UNITS Installation and user guide Count, video recording and POS control unit INDEX 1 FUNCTIONALITY... 2 2 GENERAL CONSIDERATIONS... 4 3 CAMERAS INSTALLATION... 5 3.1 CAMERA TYPES... 5 3.2

More information

16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide

16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide 16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide 1. Introduction Thank you for purchasing this 16-Port RS232 to USB2.0 High Speed Multi Serial Adapter. It is an

More information

User Guide HUAWEI UML397. Welcome to HUAWEI

User Guide HUAWEI UML397. Welcome to HUAWEI User Guide HUAWEI UML397 Welcome to HUAWEI 1 Huawei UML397 4G LTE Wireless Modem User Manual CHAPTER 1 BEFORE USING YOUR UML397 WIRELESS MODEM ABOUT THIS USER MANUAL...4 WHAT S INSIDE THE PRODUCT PACKAGE...4

More information

RS232 Programming and Troubleshooting Guide for Turbo Controls

RS232 Programming and Troubleshooting Guide for Turbo Controls RS232 Programming and Troubleshooting Guide for Turbo Controls This Troubleshooting guide is intended for the set up and troubleshooting of the control panels onboard RS232 output. Refer to the Installation

More information

RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: 91-79-4002 4896 / 97 / 98 (M) 0-98253-50221 www.interfaceproducts.info

RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: 91-79-4002 4896 / 97 / 98 (M) 0-98253-50221 www.interfaceproducts.info RS232C < - > RS485 CONVERTER S MANUAL Model: LD15U INTRODUCTION Milestone s model LD-15U is a RS232 to RS 485 converter is designed for highspeed data transmission between computer system and or peripherals

More information

Krontek. KT2000 GPS SNTP Timeserver

Krontek. KT2000 GPS SNTP Timeserver Krontek KT2000 GPS SNTP Timeserver GPS Network Timeserver - 1 - Rev 1.3b 17-Jul-2008 Table of contents Communicating with the Controller... 3 Introduction... 4 Main Menu... 4 1 - Set device Address, Mask,

More information

Network Projector Operation Guide

Network Projector Operation Guide Network Projector Operation Guide Table of contents Preparation...3 Connecting the projector with your computer...3 Wired connection... 3 Wireless connection (for selective models)... 4 QPresenter...7

More information

www.sebury.com.cn Digital Keypad Use s Manual

www.sebury.com.cn Digital Keypad Use s Manual K3 K4 www.sebury.com.cn Digital Keypad Use s Manual Contents Introduction Introduction Specifications Intramural Interface Circuit 3 Mounting 3 Wiring 5 Power UP 7 Engineer Programming Mode 7 The K3/K4

More information

ImagineWorldClient Client Management Software. User s Manual. (Revision-2)

ImagineWorldClient Client Management Software. User s Manual. (Revision-2) ImagineWorldClient Client Management Software User s Manual (Revision-2) (888) 379-2666 US Toll Free (905) 336-9665 Phone (905) 336-9662 Fax www.videotransmitters.com 1 Contents 1. CMS SOFTWARE FEATURES...4

More information

MANUAL PC1000R [email protected]

MANUAL PC1000R INFO@APART-AUDIO.COM MANUAL PC1000R [email protected] Features The APart PC1000R is a professional multisource CD/USB/SD card music player, equipped with balanced and unbalanced analog outputs, coaxial and optical digital

More information

AC-115 Compact Networked Single Door Controller. Installation and User Manual

AC-115 Compact Networked Single Door Controller. Installation and User Manual AC-115 Compact Networked Single Controller Installation and User Manual December 2007 Table of Contents Table of Contents 1. Introduction...5 1.1 Key Features... 6 1.2 Technical Specifications... 7 2.

More information

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL Rev. D PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL 10 BORIGHT AVENUE, KENILWORTH NEW JERSEY 07033 TELEPHONE: 800-524-0273 FAX: 908-686-9317 TABLE OF CONTENTS Page

More information

CONCIERGE SWITCHBOARD

CONCIERGE SWITCHBOARD SECTION 4D CONCIERGE SWITCHBOARD Download from www.urmet.com Technical Manuals area. INDICE DI SEZIONE Ref. 1083/40 2 LIST OF DETAILS...2 Keypad...2 Ringer...2 Display...2 DESCRIPTION OF CONNECTIONS...2

More information

Integrating Digiquartz MET3 and MET3A Broadband Meteorological Systems with Leica GX1200 Series GPS Receivers

Integrating Digiquartz MET3 and MET3A Broadband Meteorological Systems with Leica GX1200 Series GPS Receivers Integrating Digiquartz MET3 and MET3A Broadband Meteorological Systems with Leica GX1200 Series GPS Receivers The standard by which other standards are measured Paroscientific, Inc. 4500 148 th Ave. N.E.

More information

Temperature & Humidity SMS Alert Controller

Temperature & Humidity SMS Alert Controller Temperature & Humidity Alert Controller METERS 3 simple steps starting the unit: Insert the SIM card Plug in the sensors connectors Connect the AC power cord. Specifications: AC 90~260V Auto Select Internal

More information

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02 IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02 TABLE OF CONTENTS DESCRIPTION 2 MOUNTING INSTRUCTIONS 2 HOW TO CABLE THE IPX 2/3 POWER SUPPLY INSTALLATION 3 OPERATION 3 CARE

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS LIGHTING CONTROL PANELS 4 AND 8 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.

More information

SMAC SM Status Monitoring and Control Quality of Service (QoS) Diplex Switch Test Gear. Installation & Operation Manual

SMAC SM Status Monitoring and Control Quality of Service (QoS) Diplex Switch Test Gear. Installation & Operation Manual SM by Status Monitoring And Control Solutions (HMS Compliant, SNMP Based) SMAC SM Status Monitoring and Control Quality of Service (QoS) Diplex Switch Test Gear Installation & Operation Manual Although

More information

Adapter GL386. User Manual is available in other languages at

Adapter GL386. User Manual is available in other languages at Adapter GL386 User Manual is available in other languages at www.glipfone.com GL386 User Manual Contents: Chapter 1 Introduction ---------------------------------------------------------------- 1 Chapter

More information

Schneider Automation Modbus Plus Network Installing Clustered Node Devices 31000939 00 Version 2.0

Schneider Automation Modbus Plus Network Installing Clustered Node Devices 31000939 00 Version 2.0 Schneider Automation Modbus Plus Network Installing Clustered Node Devices 3000939 00 Version.0 Modbus Plus devices must be installed as specified in a network layout plan, showing each device s mounting

More information

CipherLab 5100 Time Attendance Utility Manual

CipherLab 5100 Time Attendance Utility Manual CipherLab 5100 Time Attendance Utility Manual K:\Products\Product Technical\BI\BI-PC5100T\CipherLab5100TimeAttendnaceUtilityManual0707-process.doc Page 1 / 13 1 Login A popup form as follows will appear

More information

Speech Dialler Engineering Information

Speech Dialler Engineering Information Speech Dialler Engineering Information Description The Informa is a Speech Dialler for use with intruder alarm systems. When the control panel recognises an alarm it triggers the Informa. The Informa uses

More information

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology FOSTCDR pn 8684R1 FOSTCDR-0812ds page 1/5 Industrial Serial to Multimode Fiber Optic Converter Data Rates up to 115.2 kbps 2.5 Mile (4 km) Range 10 to 30 VDC Input Voltage Wide Operating Temperature 2000V

More information

TrueAlarm Fire Alarm Systems

TrueAlarm Fire Alarm Systems TrueAlarm Systems UL, ULC, CSFM Listed; FM Approved* Network Annunciators; es Features Provides a dedicated local area network (LAN) for connection of a TrueSite workstation server to remote clients: es

More information

SIP Trunk Installation & User Guide

SIP Trunk Installation & User Guide PRILINK http://www.prilink.com Tel: 905-882-4488 1-866-261-0649 Fax: 905-597-1139 [email protected] [email protected] Table of Contents Overview...3 Important Terms...3 Units of Digital Information...3

More information

2013 Wireless Video Intercom INSTALLATION GUIDE

2013 Wireless Video Intercom INSTALLATION GUIDE 2013 Wireless Video Intercom INSTALLATION GUIDE INDEX System configuration and wiring VL-SWD501 System Component.. 4 VL-SWD501EX wiring schematic diagram VL-SWD501EX wiring type and length... 5.... 6 Door

More information

LBNP16312. RS-232/485/422 serial device server. User manual

LBNP16312. RS-232/485/422 serial device server. User manual Tu Sitio de Automatización! LBNP16312 RS-232/485/422 serial device server User manual Summarize-----------------------------------------------------------------------------14-3 Package checklist---------------------------------------------------------------------14-3

More information

TS510 & TS500. Installation & User Guide. Compatible Equipment

TS510 & TS500. Installation & User Guide. Compatible Equipment Installation & User Guide Compatible Equipment TS510 REM - Remote Keypad 9040 - Loudspeaker DC54/58 - Digital Communicator SD1+ - Speech Dialler 496525 Issue A 1 of 10 TS510 and TS500 Overview Introduction

More information

Fleet Tracking Capability. FX 500 / FX 250 FleetBroadband Satellite Terminal

Fleet Tracking Capability. FX 500 / FX 250 FleetBroadband Satellite Terminal Fleet Tracking Capability FX 500 / FX 250 FleetBroadband Satellite Terminal Ver : 1.0 Date : 16 Jan 2013 Contents Introduction 3 Product Overview 3 Application 4 Setting Up 5-9 Technical Summary 10-11

More information

Cable Specifications. T3 Trunk Cabling APPENDIX

Cable Specifications. T3 Trunk Cabling APPENDIX APPENDIX B This appendix contains details on the MGX 8230 cabling. It includes the following sections: T3 Trunk Cabling Frame Relay Cabling DC Power Cabling AC Power Cabling Control and Clock Cabling External

More information

Ultra Thin Client TC-401 TC-402. Users s Guide

Ultra Thin Client TC-401 TC-402. Users s Guide Ultra Thin Client TC-401 TC-402 Users s Guide CONTENT 1. OVERVIEW... 3 1.1 HARDWARE SPECIFICATION... 3 1.2 SOFTWARE OVERVIEW... 4 1.3 HARDWARE OVERVIEW...5 1.4 NETWORK CONNECTION... 7 2. INSTALLING THE

More information

INSTRUCTION MANUAL DATA EXTRACTION PROCEDURE MODEL VR-3000/VR-3000S DO NOT OPEN. Important material for the exclusive use by Investigating Authorities

INSTRUCTION MANUAL DATA EXTRACTION PROCEDURE MODEL VR-3000/VR-3000S DO NOT OPEN. Important material for the exclusive use by Investigating Authorities INSTRUCTION MANUAL DATA EXTRACTION PROCEDURE MODEL VR-3000/VR-3000S DO NOT OPEN Important material for the exclusive use by Investigating Authorities All brand and product names are trademarks, registered

More information

OWNERS MANUAL. Status Monitor. for Windows 95, 98, ME, NT 4, 2000 & XP. SIGNALCRAFTERS TECH, INC. www.signalcrafters.com

OWNERS MANUAL. Status Monitor. for Windows 95, 98, ME, NT 4, 2000 & XP. SIGNALCRAFTERS TECH, INC. www.signalcrafters.com OWNERS MANUAL Status Monitor for Windows 95, 98, ME, NT 4, 2000 & XP SIGNALCRAFTERS TECH, INC. www.signalcrafters.com 57 Eagle Rock Avenue, East Hanover, NJ 07936 Tel: 973-781-0880 or 800-523-5815 Fax:

More information

LDG DTS-4/4R Desktop Coaxial Switch / Remote

LDG DTS-4/4R Desktop Coaxial Switch / Remote LDG DTS-4/4R Desktop Coaxial Switch / Remote LDG Electronics 1445 Parran Road, PO Box 48 St. Leonard MD 20685-2903 USA Phone: 410-586-2177 Fax: 410-586-8475 [email protected] www.ldgelectronics.com

More information

Data Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION.

Data Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION. Data Bulletin 1210DB0002R3/05 03/2005 LaVergne, TN, USA Communications Wiring for POWERLINK G3 Systems Class 1210 Retain for future use. ABOUT THIS BULLETIN This data bulletin describes the proper wiring

More information

Infrastructure Management & Monitoring For Business-Critical Continuity. Liebert AC4. User Manual

Infrastructure Management & Monitoring For Business-Critical Continuity. Liebert AC4. User Manual Infrastructure Management & Monitoring For Business-Critical Continuity Liebert AC4 User Manual TABLE OF CONTENTS 1.0 INTRODUCTION 1.1 Methods of Viewing and Configuring the Liebert AC4..............................

More information

Pleiades USB/LAN. User Manual. & Installation Guide. External Storage Enclosure for 3.5 Hard Drive. v1.1

Pleiades USB/LAN. User Manual. & Installation Guide. External Storage Enclosure for 3.5 Hard Drive. v1.1 Pleiades USB/LAN External Storage Enclosure for 3.5 Hard Drive User Manual & Installation Guide v1.1 Table of Contents CHAPTER 1 - INTRODUCTION - 1 - CHAPTER 4 LAN DISK SETUP - 11 - ICON KEY - 1 - NETWORK

More information

History of Revisions. Ordering Information

History of Revisions. Ordering Information No part of this document may be reproduced in any form or by any means without the express written consent of II Morrow Inc. II Morrow, Apollo, and Precedus are trademarks of II Morrow Inc. Windows is

More information

Setting Up and Testing the MAX Hardware

Setting Up and Testing the MAX Hardware Page 1 of 12 Setting Up and Testing the MAX Hardware This chapter covers these topics: Planning the hardware installation Inserting an expansion card Setting up the hardware Connecting to input power Connecting

More information

GV-IP Decoder Box and GV-Pad

GV-IP Decoder Box and GV-Pad GV-IP Decoder Box and GV-Pad User s Manual V1.01 Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. DBV101-A-EN 2012 GeoVision,

More information

HDCVI Series DVR Quick Start Guide

HDCVI Series DVR Quick Start Guide HDCVI Series DVR Quick Start Guide Version 1.1.0 Welcome Thank you for purchasing our HDCVI DVR! This quick start guide will help you become familiar with our HDCVI DVR in a very short time. Before installation

More information

Chapter 5 Cubix XP4 Blade Server

Chapter 5 Cubix XP4 Blade Server Chapter 5 Cubix XP4 Blade Server Introduction Cubix designed the XP4 Blade Server to fit inside a BladeStation enclosure. The Blade Server features one or two Intel Pentium 4 Xeon processors, the Intel

More information

VTO6xxx. IP door stations. User manual

VTO6xxx. IP door stations. User manual VTO6xxx IP door stations User manual Table of Contents 1 Product Appearance 2 Basic Function Introduction 2.1 Call Manager Center 2.2 Call User 2.2.1 Connecting Status 2.2.2 Calling Status 2.3 Monitor

More information

Parrot MKi9000. User guide

Parrot MKi9000. User guide Parrot MKi9000 User guide Contents Contents... 2 Installation... 3 Before you begin... 3 Checking the car configuration... 3 Caution... 3 Removing the car stereo... 3 Installing the kit... 4 Car stereo

More information

GPS NTP TIME SERVER Rack Version V2.2x

GPS NTP TIME SERVER Rack Version V2.2x GPS NTP TIME SERVER Rack Version V2.2x Device Description: GPS NTP Time Server is designed to synchronize local time and date of network devices such as PCs, routers. Devices synchronize their local time

More information

DVS Net (Integration)

DVS Net (Integration) DVS Net (Integration) Installation and User s Guide Ver 11.10.x Digital Video Security System Digital Video Recorder www.tuniss.com PLEASE CALL TUNISS COMPUTER AT: 650-401-6138 FOR ANY QUASTIONS REGARDING

More information

Installation Guide Solar Connect-11

Installation Guide Solar Connect-11 Installation Guide Solar Connect-11 Version 1.1 Contents Important Product Information 3 System Registration Form 4 Solar Connect-11 Overview 5 Internet & Power Connections 6 Single Phase CT Connections

More information

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000 Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000 1.0 Introduction A Technical Application Note from Doppler System July 5, 1999 Version 3.x of the DDF6000, running version

More information

GPS NTP TIME SERVER Rack Version V2

GPS NTP TIME SERVER Rack Version V2 GPS NTP TIME SERVER Rack Version V2 Description: Server is dedicated to synchronize network devices local time/date to Universal Time (UTC) Devices synchronizing own local time through the NTP V3 protocol.

More information

SIT Sports. Safety Tracking System Manual WRC 2015

SIT Sports. Safety Tracking System Manual WRC 2015 SIT Sports Safety Tracking System WRC 2015 V2 1 SIT Sports Tracking Unit The SIT Sports Tracking unit must be fitted and connected in all competitors cars before arrival at scrutineering, where it will

More information

JEROME COMMUNICATIONS SOFTWARE (JCS) INSTALLATION and OPERATION MANUAL V1.02 for Windows XP

JEROME COMMUNICATIONS SOFTWARE (JCS) INSTALLATION and OPERATION MANUAL V1.02 for Windows XP AZI P/N 700-0042-B Last update May 2009 USER MANUAL JEROME COMMUNICATIONS SOFTWARE (JCS) INSTALLATION and OPERATION MANUAL V1.02 for Windows XP May 2009 ARIZONA INSTRUMENT LLC 3375 N Delaware Street Chandler,

More information

Application & Quick-Start Guide

Application & Quick-Start Guide Model: CRMWIC Web Intelligent Controller 1 This document will illustrate various ways to connect and use a CRM-WIC as well as programming examples. When connecting CRM-WIC, the installer has several interface

More information

Serial over Ethernet Device Server. User s Manual

Serial over Ethernet Device Server. User s Manual Serial over Ethernet Device Server User s Manual Second Edition, November 2005 SUNIX Co., Ltd. Tel : +886-2-8913-1987 Fax: +886-2-8913-1986 Http://www.sunix.com.tw [email protected] Serial over Ethernet

More information

Troubleshooting and Diagnostics

Troubleshooting and Diagnostics Troubleshooting and Diagnostics The troubleshooting and diagnostics guide provides instructions to assist in tracking down the source of many basic controller installation problems. If there is a problem

More information

LST-3800. In-Dash Digital Sonar Gauge. Installation & Operation Instructions

LST-3800. In-Dash Digital Sonar Gauge. Installation & Operation Instructions Pub. 988-0064-351 LST-3800 In-Dash Digital Sonar Gauge Installation & Operation Instructions The LST-3800 is a depth and temperature gauge that comes with a 200 khz transducer, features deep and shallow

More information

Installation Guide. Wireless N Access Point EAP110/EAP120/EAP220

Installation Guide. Wireless N Access Point EAP110/EAP120/EAP220 Installation Guide Wireless N Access Point EAP110/EAP120/EAP220 CONTENTS Network Topology 01 Hardware Overview 02 Hardware Installation 05 1. Installation Requirements... 05 2. Mounting Bracket... 05

More information

IP Matrix MVC-FIPM. Installation and Operating Manual

IP Matrix MVC-FIPM. Installation and Operating Manual IP Matrix MVC-FIPM en Installation and Operating Manual IP Matrix IP Matrix Table of Contents en 3 Table of Contents 1 Preface 5 1.1 About this Manual 5 1.2 Conventions in this Manual 5 1.3 Intended Use

More information

Ⅱ Function Characteristics

Ⅱ Function Characteristics CONTENT Ⅰ Introduction... 2 Ⅱ Function Characteristics... 2 Ⅲ Technical Parameters... 3 Ⅳ Packet List... 4 Ⅴ Components... 4 Ⅵ Installation and Connection...4 Ⅶ The Description of Basic Operations... 5

More information

AUDIO l VIDEO END-USER GUIDE. Fernwood 3E02 Conference Room System New Touch Panel

AUDIO l VIDEO END-USER GUIDE. Fernwood 3E02 Conference Room System New Touch Panel AUDIO l VIDEO END-USER GUIDE Fernwood 3E02 Conference Room System New Touch Panel Conference Room 3E02 is equipped to provide: Audio Teleconferencing Video Conferencing (with Room Support assistance).

More information

Memcom Emergency Telephone

Memcom Emergency Telephone Memcom Emergency Telephone Installation Guide Ref No. 450 900 (GB) Version 2 + + Simple wiring for quick installation + + Integrated LCD display shows you what you have programmed + + All code based programming

More information

Getting Started. Table of Contents. Hybrid IP-PBX

Getting Started. Table of Contents. Hybrid IP-PBX Hybrid IP-PBX Getting Started Model no. KX-TDA30 Table of Contents 1 Before Installation... 2 2 Installation... 4 3 Starting the Hybrid IP-PBX... 11 4 Customising the Hybrid IP-PBX... 14 5 Confirming the

More information