The Siemon Company now offers a complete end-to-end passive fiber management system for splicing,
|
|
|
- Barbra Park
- 10 years ago
- Views:
Transcription
1
2 The Siemon Company now offers a complete end-to-end passive fiber management system for splicing, patching, and storage of optical fibers in CATV Headends and Nodes, and Telco Central Offices, Shelters, and Hubs the LightWays System. UNIQUE PATENTED FEATURES All LightWays Fiber Management Products ensure that proper bend radius is maintained throughout the system and that fiber connectors are easily accessible. Features include a recessed Adapter Panel which provides ample room for patchcord exit to protect fiber cables inside the enclosures, patent-pending Bend Radius Guides for protection of fiber cables outside of the enclosure, and patent-pending Quick-Pack Adapter Panels that feature unique single-finger latch mechanism for easy accessibility to fiber connectors. Modularity is provided via use of the Quick-Pack Adapter Panels which allow for growth in 6, 8, or 12-fiber increments or with the patented one-step Adapter Bezels which allow for growth in singlefiber increments. ENCLOSURES LightWays Enclosures maximize use of valuable frame or wall space by enabling users to combine Splitter/WDM Modules with Pigtail Modules or pigtailed Quick-Pack Adapter Panels in the same enclosure. Enclosures are available to accommodate 6, 8, 12, 24, 32, 36, 48, 72, 96, or 144-fiber cables, frame mount and wall mount. DUCTING LightWays Fiber Protection System is the most cost-effective solution for routing and protecting optical cable above frames or below flooring. This unique snap-together system is quick and simple to install and easy to expand via use of patented cut-out tools for adding vertical drops. All LightWays System Products are backed by a 20 year warranty. The Siemon Company has put the pieces together to create a comprehensive passive end-to-end solution for Telco and CATV applications. Splicing Enclosures for terminating Outside Plant (OSP) Fibers to Riser OFNR cable or OFNR stub or pigtail cables routed from Patching Enclosures Patching Enclosures, pre-terminated with stubs, pigtails, or modules Patching & Splicing Enclosures, pre-terminated with stubs or pigtails Frames for mounting enclosures Interbay Storage Panels and Frame Mount Storage Enclosures for storing excess cable Modules with Pigtails, Splitters, or WDM s Patchcords for routing from enclosures to equipment or to other enclosures Fiber Protection System (Ducting) to route and protect fiber cables Software to create equipment layouts and to generate parts lists for ordering Design and installation services through a global network of Certified Installers SM and Designers
3 REFERENCE GUIDE Performance Reference TABLE OF CONTENTS Product Section LightWays 2.0 Telcordia (formally known as Bellcore), an SAIC company, is a leader in developing Generic Requirements for the telecommunications industry. They establish technical specifications which govern Generic Requirements for new or existing technologies or services. They are developed to provide customers with timely, high-quality solutions addressing their needs in such areas as: Interface Specifications Equipment Capabilities Performance Characteristics: Quality and Reliability Patching Products 3.0 Splicing Products 4.0 Patch & Splice 5.0 Accessories 6.0 Safety Markings Communications Circuit Accessory Listed per Underwriters Laboratories Standard UL 1863 or Secondary Protectors for Communications Circuits Listed per Underwriters Laboratories Standard UL 497A, or nonmetallic surface raceway and fittings Listed per UL 5A. Reference Section Application Guide 1.0 Glossary 7.0 Listed by Underwriters Laboratories to C22.2 Canadian Telecommunications Standards. ISO 9001, 9002 and 14001
4 1.1 APPLICATION THE SIEMON COMPANY LIGHTWAYS FIBER MANAGEMENT SYSTEM Adapter Bezel RB Series Enclosures up to 72 (RBC) or 96 (RBD) Fibers (with Pigtails or Pre-terminated Stub Cable) Quick-Pack Adapter Panels with Pigtails Quick-Pack Adapter Panels Pigtail Modules WPA Patch & Splice Enclosure up to 48 Fibers (with Pigtails or Pre-terminated Stub Cable) Quick-Pack Adapter Panels with Pigtails Quick-Pack Adapter Panels Pigtail Modules RPA Series Enclosure up to 144 Fibers (with Pigtails or Pre-terminated Stub Cable) End Guard Quick-Pack Adapter Panels with Pigtails Quick-Pack Adapter Panels Pigtail Modules RPB Series Enclosure (Single Shelf) up to 36 Fibers RPC Series Enclosure (Dual Shelf) up to 72 Fibers UPC or APC Cross-Connect Patchcords
5 APPLICATION 1.2 WSC Splice Enclosure accommodates 864 Fibers WSA Splice Enclosure accommodates 288 Fibers Splitter or WDM Modules RPA Series Enclosure 12 Module Capacity Fiber Distribution Frames Interbay Storage Panels RPC Series Enclosure 6 Module Capacity RPB Series Enclosure 3 Module Capacity Splitter or WDM Modules UPC or APC Equipment Patchcords LightWays Configuration Software for layouts and parts list
6 LIGHTWAYS
7 The LightWays system is a protective Fiber Management System used for routing, storing, and protecting optical fiber patchcords, pigtails, and riser cables. Applications include use in central offices, headends, shelters, hubs, nodes, customer premises data and telecommunications closets. LightWays provides a fast and simple, yet safe and efficient method of routing optical fibers among fiber distribution frames, panels, splice cabinets, and termination equipment. The LightWays Open Channel feature enables easier installation, maintenance, and additions because fibers are always accessible.
8 2.3 LIGHTWAYS DUCTING SYSTEM THE SIEMON COMPANY LIGHTWAYS The LightWays system consists of solid straight sections for horizontal routes and slotted straight sections for vertical drops. Intersections are used for making turns upward, downward, right or left, or into/across horizontal routes. Various drops permit fibers to enter equipment frames from directly overhead, offset to the front or rear of the frames. Standard mounting kits are available for attaching the system to walls, ladder racking, or directly to the frames. Vertical drops and trumpets maintain proper bend radius All parts snap together, requiring no hardware Vertical drops can be quickly added in a matter of a few minutes, by merely adding a cutout with the Cutout Tool LightWays is the only true open channel system all fiber cables can be placed into open channels rather than feeding or pulling cables through Solid straight sections are used for horizontal routes, featuring hinged lids for accessibility to fibers Vertical drops with ramps are utilized for dropping from a horizontal run to ensure proper bend radius and fiber protection Optical fibers are protected throughout the system and the design ensures proper bend radius control. Now available in 4 in. x 2 in. (100mm x 50mm) for low profile applications. This size is ideal for use where a large number of patchcords will be routed in an area with relatively low ceilings Configuration Software is available for LightWays layouts and parts list. Contact our Customer Service Department For more information call and request a free copy of the LightWays installation guide
9 LIGHTWAYS DUCTING SYSTEM 2.4 PHYSICAL CAPACITIES LWD-1XX LWD-2XX LWD-4XXLP LWD-4XX 1.25 in. x 1.25 in. 2 in. x 2 in. 4 in. x 2 in. 4 in. x 4 in. 8 in. x 4 in in. (94.1mm) 1.99 in. (50.5mm) 1.62 in. (41.2mm) 1.17 in. (29.7mm) LWD-8XX 3.71 in. (94.1mm) Internal Cross Sectional Area Patchcord Capacity * Max. Weight Capacity* Span 1.18 in. (30mm) 1.4 in 2 (891mm 2 ) 75% Physical Max lbs. (5KG) 3 ft. (0.9m) 1.97 in. (50mm) 3.9 in 2 (2525mm 2 ) 7.81 in 2 (5000mm 2 ) 14.6 in 2 (9410mm 2 ) 32.1 in 2 (20702mm 2 ) 75% Physical Max lbs. (10KG) 4 in. (100mm) 75% Physical Max lbs. (20KG) 3 ft. (0.9m) 4 ft. (1.2m) 3.94 in. (100mm) 75% Physical Max lbs. (40KG) 4 ft. (1.2m) 8.66 in. (220mm) 75% Physical Max lbs. (50KG) 6 ft. (2.0m) *Capacities based on 0.12 in. (2.9mm) diameter jumpers at lb./ft. (10 grams per meter) For other cables, it is recommended to use the following formula to calculate % fill based on the actual cable O.D. and internal cross-sectional area provided: % Fill = (# cables) X Cross sectional area of one Cable Ref: Cable cross sectional area = πr 2 Internal cross sectional area (per above table) r = cable radius (1/2 of cable O.D.), π = 3.14 STRAIGHT SECTIONS Solid straight sections are used for horizontal routes. Standard length is 6.5 ft. (2m). All straight sections are slotted at both ends to allow parts to quickly snap-together. Lids are hinged for accessibility to fibers. The straight section and lid can be cut to length on site using a common saw*. Slotted straight sections are used for vertical drops along each side of fiber distribution or terminal equipment. Standard length is 6.5 ft. (2m). Sections can be snapped together to extend vertical drops from any height. Lids are hinged for accessibility to fibers. Part # Description LWD-(XXX)* ft. (2m) Solid straight section with cover Use (XXX) to specify size, width & height: 100 = 1.25 in. x 1.25 in. (30mm x 30mm), 200 = 2 in. x 2 in. (50mm x 50mm), 400 = 4 in. x 4 in. (100mm x 100mm), 400LP = 4 in. x 2 in. (100mm x 50mm), 800 = 8 in. x 4 in. (220mm x 100mm) LWD-400 LWD-400LP LWD-(XXX) ft. (2m) Slotted straight section with cover Use (XXX) to specify size, width & height: 101 = 1.25 in. x 1.25 (30mm x 30mm), 201 = 2 in. x 2 in. (50mm x 50mm), 401 = 4 in. x 4 in. (100mm x 100mm) *Contact Customer Service for custom lengths Note: See capacity chart above for recommended fill capacity LWD-401 Slotted straight section with slot trumpet
10 2.5 LIGHTWAYS DUCTING SYSTEM THE SIEMON COMPANY INTERSECTIONS The Up and Down Vertical Elbows permit maneuvering over or under obstructions such as air conditioners, heaters, cable or ladder racking. Vertical Tees are commonly used to drop fibers from a horizontal run, with other fibers continuing along the horizontal path. Retro Vertical Tees are used for retrofitting existing site where systems must be installed around existing fiber cables. Adapters are used to maneuver left or right around obstructions. Reducer Adapters are used to interface LightWays systems of different sizes [e.g., 2 in.-to-4 in. (50mm-to-100mm)]. All adapters are supplied complete with lids. Parts are easily installed by snapping together with other sections. LWD-(XXX) Vertical elbow up, with lid Use (XXX) to specify size: 105 = 1.25 in. (30mm), 205 = 2 in. (50mm), 405 = 4 in. (100mm), 405LP = 4 in. x 2 in. (100mm x 50mm), 805 = 8 in. (220mm) LWD-(XXX) Vertical elbow up, with lid, retro fit Use (XXX) to specify size: 274 = 2 in. (50mm), 474 = 4 in. (100mm), 874 = 8 in. (220mm) LWD-(XXX) Vertical elbow down, with lid Use (XXX) to specify size: 106 = 1.25 in. (30mm), 206 = 2 in. (50mm), 406 = 4 in. (100mm), 406LP = 4 in. x 2 in. (100mm x 50mm), 806 = 8 in. (220mm), LWD Vertical elbow down, with lid, retro fit Use (XXX) to specify size: 275 = 2 in. (50mm), 475 = 4 in. (100mm), 875 = 8 in. (220mm) LWD-(XXX) Vertical tee, with lid Use (XXX) to specify size: 455 = 4 in. (100mm), 404LP = 4 in. x 2 in. (100mm x 50mm), 858 = 8 in. (220mm) LWD-(XXX) Vertical tee, with lid, retro fit Use (XXX) to specify size: 204 = 2 in. (50mm), 404 = 4 in. (100mm), 804 = 8 in. (220mm) LWD-(XXX) degree up, with lid Use (XXX) to specify size: 410 = 4 in. (100mm), 810 = 8 in. (220mm) LWD-(XXX) degree down, with lid Use (XXX) to specify size: 411 = 4 in. (100mm), 811 = 8 in. (220mm) LWD-(XXX) Centering adapter, with lid Use (XXX) to specify size: 452 = 4 in. (100mm), 854 = 8 in. (220mm) LWD-(XXX) Reducing adapter, with lid Use (XXX) to specify size and type: 266 = 2 in.-to-1.25 in. (50mm-to-30mm), Straight, 453 = 4 in.-to-2 in. (100mm-to-50mm), Straight, 452LP = 4 in. x 2 in.-to-4 in. x 4 in. (100mm x 50mm-to-100mm x 100mm), 451LP = 4 in. x 2 in.-to-2 in. x 2 in. (100mm x 50mm-to-50mm x 50mm), 850 = 8 in.-to-4 in (220mm-to-100mm), Right hand, 851 = 8 in.-to-4 in. (220mm-to-100mm), Left hand LWD-(XXX) Horizontal cross, with lid Use (XXX) to specify interface size: 202 = 2 in.-to-2 in. (50mm-to-50mm), 402 = 4 in.-to-4 in. (100mm-to-100mm), 402LP = 4 in. x 2 in. (100mm x 50mm), 802 = 8 in.-to-8 in. (220mm-to-220mm), 859 = 8 in.-to-4 in. (220mm-to-100mm) LWD-(XXX) Horizontal tee, with lid Use (XXX) to specify size: 103 = 1.25 in.-to-1.25 in. (30mm-to-30mm), 203 = 2 in.-to-2 in. (50mm-to-50mm), 403 = 4 in.-to-4 in. (100mm-to-100mm), 403LP = 4 in. x 2 in. (100mm x 50mm), 803 = 8 in.-to-8 in. (220mm-to-220mm) LWD-(XXX) Horizontal elbow. with lid Use (XXX) to specify size: 107 = 1.25 in. (30mm), 207 = 2 in. (50mm), 407 = 4 in. (100mm), 807 = 8 in. (220mm) LWD-(XXX) Storage Loop (In-line), with lid Use (XXX) to specify size: 461 = 4 in. (100mm), 862 = 8 in. (220mm)
11 LIGHTWAYS DUCTING SYSTEM 2.6 DROPS Ramps, Vertical Drops and Vertical Drop Kits are used to drop fiber cables from the horizontal run vertically to a frame. The Flared Trumpet provides bend radius protection for fiber cables exiting down a vertical tee and dropping to a frame. LWD Flared Trumpet 2 in. (50mm) LWD Flared Trumpet 4 in. (100mm) LWD Ramp 2 in. (50mm) LWD-450LP Vertical drop 4 in. x 2 in. (100mm x 50mm) LWD Vertical drop kit 2 in. (50mm) For 2 in. x 2 in. or 4 in. x 4 in. (50mm x 50mm or 100mm x 100mm) Straight Sections LWD Vertical drop kit with ramp 2 in. (50mm) For 4 in. x 4 in. or 8 in. x 4 in. (100mm x 100mm or 220mm x 100mm) Straight Sections LWD Square Tubing with lid 2 in. (50mm) Can be attached to 2 in. (50mm) Drops using LWD-208 Joiner ROUND DROPS LWD Vertical round drop 2 in. (50mm) Consists of a 2 in. (50mm) drop which allows a side exit for dropping vertically from the horizontal systems. It is used together with 2 in. (50mm) round tubing (LWD-268). Ideal for entering data cabinets with round entry holes. LWD Vertical round drop kit 2 in. (50mm) Combines vertical round drop (LWD-250) with the ramp (LWD-252). Used to guide the fibers into a vertical drop, providing proper bend radius and fiber protection. LWD Round tubing 2 in. (50mm) END CAPS & JOINERS Joiners provide the means to snap together LightWays System parts without need for hardware. LWD-(XXX) End cap Use (XXX) to specify size: 209 = 2 in. (50mm) dual knockout, 267 = 2 in. (50mm) single knockout, 409 = 14 in. (100mm), 409LP = 4 in. x 2 in. (100mm x 50mm), 809 = 8 in. (220mm) Ask about our new Enhanced slotless joiners Available Q3 LWD-(XXX) Joiner Use (XXX) to specify size: 108 = 1.25 in. (30mm), 208 = 2 in. (50mm), 408 = 4 in. (100mm), 408LP = 4 in. x 2 in. (100mm x 50mm), 808 = 8 in. (220mm)
12 2.7 LIGHTWAYS DUCTING SYSTEM THE SIEMON COMPANY RELATED PRODUCTS Open channel concept provides the most accessibility to fibers, and round tubing is also available for dropping fibers from horizontal routes to 2 in. (50mm) or 1.25 in. (30mm) vertical systems. Square tubing is available which has a unique split feature which enables the cable to be laid in. The Complete Tool Kit includes all of the tooling needed for installation of 100, 200, 400 and 800 series: cutout tools, miter boxes, and slotting tools. Cutout tools perform cutouts in the horizontal sections to permit drops. The miter boxes are used to cut the straight sections so as to ensure that the systems are cut square. Slotting tools cut the end slots that enable the LightWays system parts to snap together. The Fiber Strain Relief Kit is used to retain fiber cables at intersections, ensuring that cables lay on the bottom of the system, free from strain. Universal Radius Guides can be affixed to tees, elbows, drops, etc. to maintain a proper bend radius for exiting patchcords. The Velcro Kit is used to attach LightWays in areas where no auxiliary framework or ladder racking exists. LWD Round Tubing (Use with LWD-209 end caps) 0.75 in. (20mm) LWD Round Tubing (Use with LWD-264 end caps) 1.25 in. (30mm) LWD Square Tubing with end caps 1.25 in. (30mm) LWD Break-out blank LW-2501KIT Fiber Stain Relief Kit LWH Velcro Kit LWT Complete tool kit (for adding cutouts to straight sections) LWD Hinge Kit LWD Universal Radius Guide LWT Cutout tool, for 4 inch drops 4 in. (100mm) LWD Slot Trumpet 2 in. (50mm) (10 per pkg.)
13 LIGHTWAYS DUCTING SYSTEM 2.8 MOUNTING KITS & HARDWARE LWH Complete ladder rack mounting kit (for horizontal straight sections) 8 in. (220mm) LWH Complete ladder rack mounting kit (for horizontal straight sections) 4 in. (100mm) LWH-230 Complete ladder rack mounting kit (for horizontal straight sections) 2 in. (50mm) LWH Bracket kit (for horizontal straight sections) 2 in. (50mm) LWH Bracket Kit (for horizontal straight sections) 1.25 in. (30mm) LWH-(XXX) Bracket kit (for horizontal straight sections) Use (XXX) to specify size: 421 = 4 in. (100mm), 821 = 8 in. (220mm) LWH Vertical mount bracket kit (for vertical straight sections) 2 in. (50mm) LWH Vertical mount bracket kit (for vertical straight sections) Accommodates either 1.25 in. (30mm) or 2 in. (50mm) LWH-(XXX) Wall kit (for horizontal straight sections off walls) Use (XXX) to specify size: 425 = 4 in. (100mm), 825 = 8 in. (220mm) LWH Wall kit extension (for horizontal straight sections off walls) Accommodates either 4 in. (100mm) or 8 in. (220mm) LWH Dual level bracket (for parallel runs of horizontal straight sections, at different level) 4 in. (100mm) or 8 in. (220mm) LWH ADC adapter kit (RH) ADC 6 in. (150mm) to LW 8 in. (220mm) LWH Dual mount bracket (for parallel runs of horizontal straight sections, at same level) 4 in. (100mm) or 8 in. (220mm) LWH ADC adapter kit (LH) ADC 6 in. (150mm) to LW 8 in. (220mm) LWH-(XXX) Mounting hardware (for mounting horizontal straight sections to threaded rod) Use (XXX) to specify size: 426 = for 4 in. (100mm) ducting & 1/2 in. (13mm) threaded rod, 458 = for 4 in. (100mm) ducting and 5/8 in. (16mm) threaded rod, 826 = for 8 in. (220mm) ducting & 1/2 in. (13mm) threaded rod, 858 = for 8 in. (220mm) ducting & 5/8 in. (16mm) threaded rod LWH-822 U-Bracket Accommodates either 4 in. (100mm) or 8 in. (220mm) LWH ADC horizontal tee adapter kit (for horizontal straight sections to ADC 6 in. tee) ADC 6 in. (150mm) to LW 8 in. (220mm) LWH Straight Sections Adapter Kit (for horizontal straight sections to ADC 4 in. straight) ADC 4 in. (100mm) to LW 4 in. (100mm) LWH ADC horizontal tee adapter kit (for horizontal straight sections to ADC 4 in. tee) ADC 4 in. (100mm) to LW 4 in. (100mm) LWH Auxiliary frame kit (for threaded rod to ladder rack) 5/8 in. (16mm) threaded rod LWH Auxiliary frame kit (for threaded rod to ladder rack) 1/2 in. ( 13mm) threaded rod
14 2.9 LIGHTWAYS DUCTING SYSTEM THE SIEMON COMPANY DROP APPLICATIONS Figure 1: 4 in. (100mm) vertical drop from 8 in. (220mm) horizontal straight section [LWD-800] A, using an 8 in. (220mm) vertical tee [LWD-858] B, flared trumpet [LWD-462] C, two 8 in. (220mm) joiners [LWD-808] D, and one joiner 4 in. (100mm) [LWD-408] E. A B D D E C Figure 2: 4 in. (100mm) vertical drop from 4 in. (100mm) horizontal straight section [LWD-400] A, using 4 in. (100mm) vertical tee [LWD-455] B, 4 in. (100mm) flared trumpet [LWD-462] C and three 4 in. (100mm) joiners [LWD-408] D. A B D D D C Figure 3: 2 in. (50mm) vertical drop kit [LWD-265] B from 4 in. (100mm ) horizontal straight section [LWD-400] A, using 2 in. (50mm) cutout tool [LWT-022], included with the complete tool kit. Same vertical drop can be used with 2 in. (50mm) [LWD-200], 4 in. x 2 in. (100mm x 50mm) or 8 in. (220mm) [LWD-800] horizontal straight sections. Also, 2 in. x 2 in. (50mm x 50mm) slotted straight section (LWD-201 kit) can be attached to LWD-265. See photo on page 1.3. A B
15 LIGHTWAYS DUCTING 2.10 DROP APPLICATIONS Figure 4: 4 in. (100mm) vertical drop from 4 in. (100mm) horizontal straight section [LWD-400] A, using 4 in. (100mm) horizontal tee [LWD-403] B, 4 in. (100mm) elbow down [LWD-406] C, and 4 in. (100mm) flared trumpet [LWD-462] D, and five 4 in. (100mm) joiners [LWD-408] E. A B E E C E D Figure 5: 4 in. (100mm) vertical drop from 4 in. (100mm) horizontal straight section [LWD-400] A, using 4 in. (100mm) cut-out tool [LWT-029] not included with complete tool kit, 4 in. (100mm) flared trumpet [LWD-462] B, 4 in. (100mm) elbow down [LWD-406] C, and 4 in. (100mm) flared trumpet [LWD-462] D and two 4 in. x 2 in. (100mm x 50mm) joiners [LWD-408] E. A B C E D Figure 6: 2 in. (50mm) vertical drop from 4 in. x 2 in. (100mm x 50mm ) horizontal straight section [LWD-400LP] A, using 2 in. ( 50mm) cut-out tool [LWT-022], 4 in. x 2 in. (100mm x 50mm) vertical drop [LWD-462LP] B, 4 in. x 2 in. (100 x 50mm) vertical 90 degree elbow down [LWD-406LP] C, and one 4 in. (100mm) joiner [LWD-408LP] D. A B D C
16 PATCHING The RP series Frame Mount Enclosures provide a means to patch fiber cabling on an equipment frame utilizing 6, 8, or 12-fiber Quick-Pack adapter panels. These enclosures are available in three versions and accommodate fiber counts from 6 to 144. The RB series utilize single-fiber adapter bezels and accommodate up to 72 or 96 fibers. Enclosures are available loaded with Quick-Pack Adapter Panels or Bezels pre-terminated with cable stubs. They also accommodate Pigtail, Splitter, and WDM type modules. Bend Radius is maintained inside via the recessed adapter panel and outside via the patentpending Bend Radius Guides.
17 PATCHING ENCLOSURES COMPARISON CHART Enclosure Adapter Fiber Mounting Height Pigtail Splitter/WDM Style Style Capacity Orientation Width (RMS) Option Compatible Page RPA Panels 72/96/144 Universal 19 or 23 inch RPB Panels 18/24/36 Universal 19 or 23 inch 1 * 3.4 RPC Panels 36/48/72 Universal 19 or 23 inch 2 * 3.5 RBA Bezels 72 Front 23 inch RBB Bezels 96 Front 23 inch RBC Bezels 72 Universal 23 inch RBD Bezels 96 Universal 23 inch * Must be ordered separately Notes: 1 RMS = 1.75 in. (4.5mm) Universal = Front or Rear Frame-Mount Panels: See pages Bezels: See page 3.13 A unique packaging system protects the pre-terminated fibers within the enclosure during transportation and installation. This Universal Reel Package is compact for easy transportation during shipping and installation. Enclosures are encased within impact-resistant foam to protect all fibers and terminations. Cable is stored on a durable reel to allow for quick, easy pay-out to the splice location. The wood reel flange is removed to access the stored enclosure.
18 3.2 PATCHING PRODUCTS THE SIEMON COMPANY RPA UNIVERSAL-MOUNT ENCLOSURE Fiber connectivity is provided via 6, 8, or 12-fiber Quick-Pack Adapter Panels which enable incremental growth. Enclosures can be mounted onto either 19 inch (482.6mm) or 23 inch (584mm) frames and are available with the following options: Empty Pre-loaded with Quick-Packs Pre-loaded with Quick-Packs and Pigtails Pre-loaded with Quick-Packs and Stub (stranded or ribbon cable) Integrated Latches The patent-pending Quick-Pack Adapter Panels enable single-finger insertion and removal for easy cleaning and additions Modular Versatility Enclosures accommodate any combination of Quick-Packs, Splitter, Pigtail or WDM Modules Patent-pending Bend Radius Guides Maintain proper bend radius for all cables exiting the Quick-Packs or Modules, even with door open Accommodates standard 72-fiber, 96-fiber plus hi-density 144-fibers Available with a variety of connector types, including SC, FC, ST or LC, featuring UPC or APC performance Quick-Pack Adapter Panels accommodate numerically pre-printed fiber ID labels and snap-in clear covers. Color-coded snap-in icon tabs are also available Enclosure and mounting brackets are designed to enable universal mounting to either the front or the rear of the frame Convenient flip-type port identification cards attached to the smoked polycarbonate front door Front and rear doors are secured by a single slam latch and doors can be removed via activation of spring-loaded hinges Stubbed enclosures are supplied within a compact cable storage reel 25 in. H x 23 in. in diameter (635mm x 584mm) 4-RMS, 7 in. H x 17 in. W x 12 in. (180mm H x 430mm W x 305mm) (LGX-compatible) Note: 1 RMS = 1.75 in. (4.5mm)
19 PATCHING PRODUCTS 3.3 ORDERING INFORMATION RPA- A 1 A A Connector/ Adapter type: Singlemode- A = FCUPC B = SCUPC C = SCAPC D = STUPC E = LCUPC F = LCAPC G = FCAPC narrow key H = FCAPC wide key X = no adapters Color: A = beige # of Fibers terminated: for example 072 = 72 fibers 096 = 96 fibers 144 = 144 fibers blank = not applicable Pigtails: 1 = loaded with pigtails Rear Stub Location: 2 = top right 3 = bottom right 4 = top left 5 = bottom left blank = not applicable Enclosure contents: 1 = Empty (no adapters) 2 = with Adapters only (6-packs) 3 = with Adapters & Pigtails (6-packs) 4 = with Adapters & Stub (6-packs) A = with Adapters only (8-packs) B = with Adapters & Pigtails (8-packs) C = with Adapters & Stub (8-packs) D = with Adapters only (12-packs) E = with Adapters & Pigtails (12-packs) F = with Adapters & Stub (12-packs) Cable Type: Singlemode- A = pigtail, jacketed B = pigtail, buffered C = OFNR stranded D = OFNR ribbon E = Plenum stranded F = Plenum ribbon G = OSP stranded H = OSP ribbon blank = not applicable Stub or Pigtail length: (meters) 05 =5m 10 = 10m blank = not applicable
20 3.4 PATCHING PRODUCTS THE SIEMON COMPANY RPB UNIVERSAL-MOUNT SINGLE-SHELF ENCLOSURE The compact design of this 1 RMS enclosure maximizes valuable frame space. Fiber Management is provided via Fiber Modules which incorporate a unique, patent-pending Quick- Pack latching mechanism. Modules are available with Splitters, WDMs or preterminated Pigtails. Enclosures can be mounted onto a 19 inch (482.6mm) or 23 inch (584mm) frame. Enclosures can also accommodate up to 3 Quick- Pack Adapter Panels. Modules and Quick-Pack Adapter Panels can also be used in combination. Integrated Latches Patent-pending Quick-Pack Module latches enable snap-in insertion and quick release for easy adds and changes Modular Versatility Enclosures accommodate any combination of Quick-Packs, Splitter, Pigtail or WDM Modules Accessibility to Connections Accessibility is made easy via a 3-position drawer design that slides out the front or the rear Modular versatility enclosure accommodates Splitter/Pigtail/WDM Modules as well as Quick- Pack Adapter Panels to enable use for splicing and patching Modules available with a variety of connector types, including SC, FC, ST or LC, featuring UPC or APC performance The 3-position slide-out drawer enables front access to the patchcord connections at the 1st stop, to the module connections and pigtail connectors at the 2nd stop, and complete removal at the 3rd position. The drawer also slides out from the rear with 2 stops for removal Part # Description RPB-X1A RMS Frame-Mounted Enclosure, accommodates up to three Modules or Adapter Panels Note: 1 RMS = 1.75 in. (4.5mm) Convenient slide-in port identification labels attach to a label holder that is readily removable via release of snap latches ID labels are printable via a standard desktop printer using software available on our website 1 RMS, 1.75 in. H x 17 in. W x 12 in. D (69mm H x 430mm W x 305mm D) For Pigtailed and Stubbed options see Patch & Splice Section See page 3.10 & 3.11 for module ordering information
21 PATCHING PRODUCTS 3.5 RPC UNIVERSAL-MOUNT DUAL-SHELF ENCLOSURE The compact design of this 2 RMS enclosure maximizes valuable frame space. Fiber Management is provided via Fiber Modules which incorporate a unique, patent-pending Quick- Pack latching mechanism. Modules are available with Splitter, WDMs or pre-terminated Pigtails. Enclosures can be mounted onto a 19 inch (482.6mm) or 23 inch (584mm) frame. Enclosures can also accommodate up to 6 Quick- Pack Adapter Panels. Modules and Quick-Pack Adapter Panels can also be used in tandem. Integrated Latches Patent-pending Quick-Pack Module latches enable snap-in insertion and quick release for easy adds and changes Modular Versatility Enclosures accommodate any combination of Quick-Packs, Splitter, Pigtail or WDM Modules Accessibility to Connections Accessibility is made easy via a 3-position drawer design that slides out the front or the rear Modules available with a variety of connector types, including SC, FC, ST or LC, featuring UPC or APC performance The 3-position slide-out drawer enables front access to the patchcord connections at the 1st stop, to the module connections and pigtail connectors at the 2nd stop, and complete removal at the 3rd position. The drawer also slides out from the rear with 2 stops for removal Convenient slide-in port identification labels attach to a label holder that is readily removable via release of snap latches ID labels are printable via a standard desktop printer using software available on our website 2 RMS, 3.50 in. H x 17 in. W x 12 in. D (89mm H x 430mm W x 305mm D) For Pigtailed and Stubbed options see Patch & Splice Section Part # Description RPC-X1A RMS Frame-Mounted Enclosure, accommodates up to six Modules or Adapter Panels Note: 1 RMS = 1.75 in. (44.5mm) See page 3.10 & 3.11 for module ordering information
22 3.6 PATCHING PRODUCTS THE SIEMON COMPANY RBA & RBB FRONT-MOUNT ENCLOSURES Fiber connectivity is provided via utilization of one-step, snap-in Adapter Bezels which enable single-fiber incremental growth. Enclosures can be mounted onto a 23 inch (584mm) frame which has tapped holes located at 22 5/16 (559mm) center-to-center. Enclosures are available with the following options: Empty Pre-loaded with Adapter Bezels Integrated Latches The Adapter Bezels enable one-step, snap-in insertion and removal for easy cleaning and additions Recessed Adapter Panel Provides ample room for patchcord exit at front of enclosure to provide proper bend radius. Dual-level clips enable effective management of up to 96 fibers at rear of enclosure Standard 72-fiber or 96-fiber versions Enclosure and mounting ears are designed for mounting to the front of the frame Available with a variety of connector types, including SC, FC, ST or LC, featuring UPC or APC performance All ports are labeled 1-72 (or 1-96) in the front and in the rear for easy ID Optional port numbering is available Convenient flip-type port identification cards are attached to the smoked polycarbonate front door Front door is secured by a single slam latch and the door can be removed via activation of springloaded hinges 4.5 RMS 8 in. H x 21.6 in. W x 9.75 in. D (200mm H x 550mm W x 250mm D) Note: 1 RMS = 1.75 in. (4.5mm)
23 PATCHING PRODUCTS 3.7 ORDERING INFORMATION RBA- A 1 A Type of Enclosure: RBA = 72-fiber RBB = 96-fiber Color: A = beige Connector/ Adapter type: Singlemode- A = FCUPC B = SCUPC C = SCAPC D = STUPC E = LCUPC F = LCAPC G = FCAPC narrow key H = FCAPC wide key X = no adapters Enclosure contents: 1 = Empty (no Adapters) 2 = with Adapters
24 3.8 PATCHING PRODUCTS THE SIEMON COMPANY RBC & RBD UNIVERSAL-MOUNT ENCLOSURES Fiber connectivity is provided via utilization of one-step, snap-in Adapter Bezels which enable enable single-fiber incremental growth. Enclosures can be mounted onto a standard 23 inch (584mm) frame and are available with the following options: Empty Pre-loaded with Adapter Bezels Pre-loaded with Adapter Bezels and Stub (stranded or ribbon cable) One-Step Bezel The Adapter Bezels enable one-step, snap-in insertion and removal for easy cleaning and additions Recessed Adapter Panel Provides ample room for patchcord exit from adapter, ensuring proper bend radius inside the enclosure Patent-pending Bend Radius Guides Maintain proper bend radius for all cables exiting the enclosure, even with door open Standard 72-fiber or 96-fiber versions Enclosure and mounting brackets are designed to enable universal mounting: to either the front or the rear of frame Available with a variety of connector types, including SC, FC, ST or LC, featuring UPC or APC performance All ports are labeled 1-72 (or 1-96) in the front and rear for easy identification Optional port numbering is available Convenient flip-type port identification cards are attached to the smoked polycarbonate front door Front and rear doors are secured by a single slam latch and doors can be removed via activation of spring-loaded hinges 4 RMS, 8 in. H x 21.6 in. W x 12 in. D (200mm H x 550mm W x 305mm D) Note: 1 RMS = 1.75 in. (4.5mm)
25 PATCHING PRODUCTS 3.9 ORDERING INFORMATION RBC- A 1 A A Type of Enclosure: RBC = 72-fiber RBD = 96-fiber Color: A = beige Pigtails: 1 = loaded with pigtails Stub Location: 2 = top right 3 = bottom right 4 = top left 5 = bottom left blank = not applicable Connector/ Adapter type: Singlemode- A = FCUPC B = SCUPC C = SCAPC D = STUPC E = LCUPC F = LCAPC G = FCAPC narrow key H = FCAPC wide key X = no adapters Enclosure contents: 1 = Empty (no Adapters) 2 = with Adapters only 3 = with Adapters & Pigtails 4 = with Adapters & Stub # of Fibers terminated: for example 072 = 72 fibers 096 = 96 fibers blank = not applicable Cable Type: Singlemode- A = pigtail, jacketed B = pigtail, buffered C = OFNR stranded D = OFNR ribbon E = Plenum stranded F = Plenum ribbon G = OSP stranded H = OSP ribbon Blank = not-applicable Stub or Pigtail length (meters): 05 =5m 10 = 10m blank = not applicable
26 3.10 PATCHING PRODUCTS THE SIEMON COMPANY QUICK-PACK SPLITTER & WDM MODULES Fiber Modules are available with Splitter or WDM components neatly housed inside a protective module. Modules are supplied with all Splitter or WDM leads terminated and mated to bulkhead adapters. Splitters are available in various split ratios and configurations (1 x N). WDM s are available in standard isolation (15dB far end) or high-isolation (45dB far end). Modules can be supplied with a variety of popular connector types including SC, FC, ST or LC, featuring UPC or APC performance. All Modules feature the patent-pending easy-snap latch mechanism for simplified mounting into RPA, RPB, RPC or WPA enclosures. Meets Telcordia GR1209-CORE specifications. Splitter Specifications Materials Fiber: Corning SMF-28 Housing: SS Tube (Meets UL94V-1) Optical Bandpass: nm nm Directivity: 55dB Min. Polarization Stability: 0.5dB max Reflectance: <-55dB Insertion Loss: 50:50 3.1/3.1 typ 3.6/3.6 max Environmental Temperature: -40 to +75C Materials Fiber: Housing: Optical Bandpass: WDM Specifications Uniformity: Stability: Reflectance: Insertion Loss: Isolation: Environmental Temperature: -40 to +75C Corning SMF-28 Enclosed Module (Meets UL94V-1) nm nm 1.0 Log 2 N Polarization 0.5dB max <-55dB Mux/Demux 0.3dB max Near End -55dB, Far End -15dB ORDERING INFORMATION SM-B A A Product Type: SM = Splitter Module Adapter Mounting: F = Fixed B = Bezel # of Ports/split ratio: 150 = 1x2, 50: = 1x2, 55: = 1x2, 60: = 1x2, 65: = 1x2, 70: = 1x2, 75: = 1x2, 80: = 1x2, 85: = 1x2, 90: = 1x2, 95: = 1x2, 50:50 (2 ea.) 333 = 33:33: = 25:25:25: = 20:20:20:20:20 WDM Bi-Directional type: 001 = (1x2), 1.3mmTX/1.5mmRX, standard isolation 002 = (1x2), 1.3mmRX/1.5mmTX, standard isolation 003 = (1x2), 1.3mmTX/1.5mmRX, high isolation 004 = (1x2), 1.3mmRX/1.5mmTX, high isolation 021 = 2(1x2), 1.3mmTX/1.5mmRX, standard isolation 022 = 2(1x2), 1.3mmRX/1.5mmTX, standard isolation Connector/ Adapter type: Singlemode- A = FCUPC B = SCUPC C = SCAPC D = STUPC E = LCUPC F = LCAPC G = FCAPC narrow key H = FCAPC wide key Module Color: A = light ivory
27 PATCHING PRODUCTS 3.11 QUICK-PACK PIGTAIL MODULES Fiber Modules are available with Pigtails exiting the rear of the module. All components are neatly housed inside the module, ensuring proper fiber management and protection of the internal components. A variety of popular connector types (SC, FC, ST, LC) are available, featuring UPC or APC performance. All Modules are 100% factory tested. Insertion and return loss data provided. Quick-Pack Pigtail Modules feature the patent-pending easy-snap latch mechanism for simplified mounting into an RPA, RPB, RPC or WPA enclosure. ORDERING INFORMATION PM - B A 6 R A A Product Type: PM = Pigtail Module Cable Rating: R = Riser P = Plenum Module Color: A = light ivory Adapter Mounting: F = Fixed B = Bezel # Fibers: A =6 C =12 Cable Type: 6 = Jacketed fiber Connector/ Adapter type: Singlemode- A = FCUPC B = SCUPC C = SCAPC D = STUPC E = LCUPC F = LCAPC G = FCAPC narrow key H = FCAPC wide key Cable length: (meters) 01 =1m 10 = 10m blank = not applicable
28 3.12 PATCHING PRODUCTS THE SIEMON COMPANY QUICK-PACK ADAPTER PANEL W/PIGTAILS As an option to enclosed Modules, Quick-Pack Adapter Panels can be provided with Pigtails pre-assembled. Each set of buffered fiber pigtails are enshrouded within a protective sleeve. A variety of popular connector types (SC, FC, ST, LC) are available, featuring UPC or APC performance. All Pigtails are 100% tested for insertion and return loss. Quick-Packs with Pigtails feature the patent-pending, single-finger latch mechanism for easy mounting into RPA, RPB, RPC, or WPB enclosures. Fiber Modules (Splitter, WDM, or Pigtail) can be mounted in the same enclosures in place of or in tandem with Quick-Packs with Pigtails. OPTICAL PERFORMANCE LIMITS Polish Type UPC APC Max. Insertion Loss (db) 0.5 db (0.25 Typical) Min. Return Loss (db) Legend (Return Loss performance level): UPC = Ultra PC (Physical Contact) APC = Angled PC (Physical Contact) ORDERING INFORMATION - QP F A 3 R A B Product Type: QP = Quick Pack with pigtails Cable Rating: R = Riser P = Plenum Adapter Color: B = white Adapter Mounting: F = Fixed Cable Type: 3 = SM fiber # of Fiber: A =6 B =8 C =12 Connector/ Adapter type: Singlemode- A = FCUPC B = SCUPC C = SCAPC D = STUPC E = LCUPC F = LCAPC G = FCAPC narrow key H = FCAPC wide key Cable length: (meters) 01 =1m Other lengths available upon request
29 PATCHING PRODUCTS 3.13 QUICK-PACK ADAPTER PANELS RIC-F-SA ST/UPC (6-pack) with 6 fiber ID pockets RIC-F-SA ST/UPC (8-pack) with 4 fiber ID pockets RIC-F-SCU SC/UPC (6-pack) with 6 fiber ID pockets RIC-F-SCA SC/APC (6-pack) with 6 fiber ID pockets RIC-F-SA ST/UPC (12 pack) [not shown] RIC-F-SCU SC/UPC (8-pack) with 4 fiber ID pockets RIC-F-SCA SC/APC (8-pack) with 4 fiber ID pockets RIC-F-SCU SC/UPC (12-pack) RIC-F-SCA SC/APC (12-pack) RIC-F-FC FC/UPC (6-pack) with 6 fiber ID pockets RIC-F-FCN FC/APC (6-pack) narrow key, with 6 fiber ID pockets RIC-F-LCU LC (12-pack) with 6 fiber ID pockets RIC-F-BLNK Blank adapter plate RIC-F-FC FC/UPC (8-pack) with 4 fiber ID pockets [not shown] RIC-F-FCN FC/APC (8-pack) narrow key, with 4 fiber ID pockets [not shown] All adapters are off white APC adapters employ ceramic alignment sleeves. All others employ metal sleeves, but are available with ceramic sleeves by adding -C at the end of the part number. Each adapter panel with icon pockets includes red, blue, color matching, and clear icons with paper labels. Adapters are universal to support multimode and singlemode fiber applications ADAPTER BEZELS Adapter Bezels consist of one adapter (or bulkhead) installed into a molded bezel which snaps into any of the RB type enclosures or the pigtail/splitter WDM modules. Adapter Bezels enable single fiber additions and easy access to the connectors for cleaning. Adapter Bezels can be supplied with a variety of popular connector types including SC, FC, ST, or LCs, featuring UPC or APC polish. MX-F1-LCU LC/UPC Duplex adapter bezel MX-F1-SCU SC/UPC adapter bezel MX-F1-SCA SC/APC adapter bezel MX-F1-SA ST/UPC adapter bezel MX-F1-FC FC/UPC adapter bezel MX-F1-FCN FC/APC narrow key adapter bezel MX-F1-BL Blank adapter All bezels are light ivory. (Other colors available) APC adapters employ ceramic alignment sleeves. All others employ metal sleeves but are available with ceramic sleeves by adding -C at the end of the part number. MX-F1-LCU MX-F1-SCU MX-F1-SA MX-F1-FCN MX-F1-BL All adapters are in compliance with ANSI/TIA/EIA-604 intermateability standards and Telcordia GR-326 specifications. Insertion Loss Contribution: 0.20 db (metal sleeve), 0.10 db (ceramic sleeve)
30 SPLICING The new LightWays Splicing Enclosure provides a wall mount storage area for trunk and riser cable slack and splice trays. The Splice Enclosures accommodate 288 or 864 fibers. The 288-fiber splice enclosure features a patent-pending Slide-in Cable Entry making additions quick and easy. Key-hole mounting brackets enable installation by a single technician.
31
32 4.2 SPLICING PRODUCTS THE SIEMON COMPANY SPLICE ENCLOSURE The LightWays Splice Enclosures are feature-rich wall mount fiber protection enclosures for splicing and storing trunk and riser cables. These enclosures include many unique features such as slide-in cable slots, generous bend radius control, and easy access cable management. Radius guards ensure proper bend radius and efficiently manage fibers Slide-in cable entry enables cables to be added quickly and easily (WSA) Versatile cable clamp accommodates a wide variety of cable sizes Accommodates 288 (WSA) or 864 (WSC) fibers Patent-pending Slide-in Cable Entry [Cable diameter range.375 in in. (3.25mm mm)] Top, bottom and side cable entry options Key-hole mounting brackets for single technician installation Enclosures are manufactured using 13-gauge aluminum with a durable beige finish Full bend radius protection Removable door can be mounted on the left or right of the enclosure Door is tool lockable (WSA) On-door documentation holder Enclosure dimensions: WSA: 22 in. W x 29 in. H x 9 in. D (559mm W x 737mm H x 229mm D) WSC: 32.2 in. W x 60.2 in. H x 14 in. D (819mm W x 1529mm H x 356mm D) Part # Description WSA-Y5A Fiber Splice Enclosure WSC-Y5A Fiber Splice Enclosure
33 SPLICING PRODUCTS 4.3 FIBER SPLICE TRAYS These aluminum trays are equipped with splice holders to accommodate fusion, mechanical or fusion with sleeve splicing and come with a clear, snap-on polycarbonate cover. The standard tray holds up to 24 splices and, for tighter access, a mini-tray is available which accommodates up to 12 splices. Trays can be stacked for high-density applications. Standard tray dimensions: width: 4.07 in. (103mm) length: in. (298mm) height: 0.32 in. (8.13mm) Mini tray dimensions: width: 4.07 in. (103mm) length: 7.06 in. (179mm) height: 0.32 in. (8.13mm) Part # Description TRAY-(X) Standard fiber splice tray for up to 24 splices TRAY-M-(X) Mini fiber splice tray for up to 12 splices Use (X) to specify type of splice holder: 1 = fusion, 2 = mechanical, 3 = fusion with sleeve Notes: Mechanical splice holders are compatible with GTE elastomeric, Siecor Camsplice, Norland splice and Lucent CSI. Fusion with sleeve splice holders can accommodate sleeve diameters from in. (1.5mm) to in. (2mm) Standard Fusion splice holders are designed for 900 micron buffered fibers or 250 micron coated fibers STRAIN RELIEF CLAMP This clamp is designed to provide additional strain relief for fiber cables entering and exiting LightWays Splice Enclosures and are designed to accommodate cable outside diameters ranging from.375 inch (3.25mm) to inch (28.6mm). The clamp can be secured quickly and easily to the cable seals in the enclosures. Cable Clamp Part # Description WS-C-A Strain relief cable clamp for LightWays splice enclosures
34 PATCH & SPLICE WPA Wall Mount Patch & Splice enclosures are ideal for use in Premises Applications such as dropping fibers to residential customers, business customers, or schools. The design minimizes the wall space required for accommodating up to 48 fibers within a single, compact enclosure. The enclosure will accept up to four Quick-Pack Adapter Panels. It can be supplied empty, loaded with Quick-Packs, loaded with Pigtails, or pre-terminated with a stub cable (ribbon or stranded). A wide range of connector types are available including ST, SC, FC and LC, featuring UPC or APC performance. All Pigtails and Stubs are 100% tested for Insertion Loss/Return Loss. Quick-Packs feature the patent-pending, single-finger latch mechanism for easy installation and servicing. (See Accessories and Patching Sections for more information.)
35 RPB and RPC Frame Mount Patch & Splice enclosures are ideal for use in areas where frame space is limited or fiber counts are relatively small. They are also ideal for users want to grow their networks in small increments (6, 8, or 12- fibers at a time).
36 5.2 PATCH & SPLICE THE SIEMON COMPANY WPA WALL-MOUNT ENCLOSURE This wall-mount enclosure provides a means of splicing and patching up to 24 or 48 fibers within a small wall area. The low-profile, compact design makes it ideal for installation areas where space is at a minimum. WPA enclosures house terminated fibers dropped from trunk or feeder cables to Customer Premises. Fiber Management is provided via utilization of Quick-Pack Adapter Panels. Quick-Packs enable 6, 8, or 12-fiber incremental growth. Enclosures are available with the following options: Empty Pre-loaded with Quick-Pack Adapter Panels Pre-loaded with Quick-Packs, Pigtails, and Splice Tray(s) Pre-loaded with Quick-Packs and Stub (stranded or ribbon cable) Integrated Latches The patent-pending Quick-Pack Adapter Panels enable single-finger insertion and removal for easy cleaning and additions Modular Versatility Enclosures accommodate any combination of Quick-Packs, Splitter, Pigtail or WDM Modules Optimum Access Enclosure and Guard doors swing open a full 180 to provide optimum front and side access Quick-Packs are available with a variety of connector types, including SC, FC, ST or LC, featuring UPC or APC performance An integrated Patchcord Guard provides patchcord protection and management Doors can be ordered with key lock, latching or socket head lock options Splice trays are mounted to an elevated bracket for improved access A strain-relief thumbscrew and lug are included for securing the cable s aramid strength members and central strength member respectively. In addition, lanced tabs provide anchor points for use of cable ties to secure the cable jacket Dust-proofing grommets are included Compression Fitting Conversion Kit is available separately as an optional method to secure the cable (see page 5.3) Convenient labeling system on Network side includes removable clear envelope for storing and protecting fiber documentation Labeling is also provided for Customer side via a stick-on sheet attached to the Patchcord Guard door Compact in. H x 16 in. W x 3.25 in. D (311mm H x 406mm W x 83mm D)
37 PATCH & SPLICE 5.3 ORDERING INFORMATION W P A - A 1 B N 2 4 A Connector/ Adapter type: Singlemode- A = FCUPC B = SCUPC C = SCAPC D = STUPC E = LCUPC F = LCAPC G = FCAPC narrow key H = FCAPC wide key X = not applicable Enclosure contents: 1 = Empty (no adapters) 2 = with Adapters only (6-packs) 3 = with Adapters & Pigtails (6-packs) 4 = with Adapters & Stub (6-packs) 5 = not applicable A = with Adapters only (8-packs) B = with Adapters & Pigtails (8-packs) C = with Adapters & Stub (8-packs) D = with Adapters only (12-packs) E = with Adapters & Pigtails (12-packs) F = with Adapters & Stub (12-packs) Color: B = white C = black # of Fibers terminated: for example: 12 = 12 fibers 24 = 24 fibers blank = not applicable Door Latch: K = key lock, both doors N = key lock on network door, thumb latch on customer door T = thumb latch, both doors W = socket head lock, both doors Pigtails: 1 = loaded with pigtails Stub Location: 2 = top 3 = bottom blank = not applicable Cable Type: Singlemode- A = pigtail, jacketed B = pigtail, buffered C = OFNR stranded D = OFNR ribbon E = Plenum stranded F = Plenum ribbon G = OSP stranded H = OSP ribbon Blank = not applicable Stub or Pigtail length (meters): 05 =5m 10 = 10m blank = not applicable COMPRESSION FITTING CONVERSION KIT Conversion kits provide a means of securing fiber cables to the WPA enclosure. These fittings are liquid tight up to 70 psi water pressure and resist salt water, weak acids, gasoline, alcohol, oil, grease and common solvents. Acme threads on the body prevent skipping, allowing for faster installations of lock nuts. Part # Description CF-(XX)-SP-(XX) Compression fitting conversion kit Use first (XX) to specify duct/cable accommodation size: 40 = 24-fiber distribution cable, 51 = 36-fiber distribution cable Use 2nd (XX) to specify color: 01 = black, 02 = white
38 5.4 PATCH & SPLICE THE SIEMON COMPANY RPB & RPC FRAME-MOUNT ENCLOSURES The compact design of these enclosures maximizes valuable frame space. Fiber Management is provided via utilization of Quick- Pack Adapter Panels. Quick- Packs enable 6, 8, or 12-fiber incremental growth. Enclosures can be mounted onto a 19 inch (482.6mm) or 23 inch (584mm) frame and are available with the following options. Empty Pre-loaded with Quick-Pack Adapter Panels Pre-loaded with Quick-Packs, Pigtails, and Splice Tray(s) Pre-loaded with Quick-Packs and Stub (stranded or ribbon cable) Integrated Latches The patent-pending Quick-Pack Adapter Panels enable single-finger insertion and removal for easy cleaning and additions Modular Versatility Enclosures accommodate any combination of Quick-Packs, Splitter, Pigtail or WDM Modules Accessibility to Connections Accessibility is made easy via a 3-position drawer design that slides out the front or the rear RPB accommodates three 6, 8, or 12-fiber Quick-Pack Adapter Panels enabling a combination that yields from 6 to 36 fibers RPC accommodates six 6, 8, or 12-fiber Quick-Pack adapter panels enabling a combination that yields from 6 to 72 fibers Splice trays can be mounted to the rear of drawer for spicing up to 36 fibers within the RPB enclosure and up to 72 fibers within the RPC enclosure Available with a variety of connector types, including SC, FC, ST or LC, featuring UPC or APC performance The 3-position slide-out drawer enables front access to the patchcord connections at the 1st stop, to the module connections and pigtail connectors at the 2nd stop, and complete removal at the 3rd position. The drawer also slides out from the rear with 2 stops for removal A compression fitting is available separately as optional method to secure the cable (see page 5.5) Quick-Pack Adapter Panels accommodate numerically pre-printed fiber ID labels and snap-in clear covers. Color-coded snap-in icon tabs are also available Convenient slide-in port identification labels attach to a label holder that is readily removable via release of snap latches ID labels are printable via a standard desktop printer and software available on our website Enclosure dimensions: RPB: 1.75 in. H x 17 in. W x 12 in. D (45mm H x 430mm W x 305mm D) RPC: 3.50 in. H x 17 in. W x 12 in. D (89mm x H x 430mm W x 305mm D)
39 PATCH & SPLICE 5.5 ORDERING INFORMATION RPB- A 1 A A Connector/ Adapter type: Singlemode- A = FCUPC B = SCUPC C = SCAPC D = STUPC E = LCUPC F = LCAPC G = FCAPC narrow key H = FCAPC wide key X = not applicable Type of Enclosure: RPB = 1-shelf RPC = 2-shelf Color: A = beige Enclosure contents: 1 = Empty (no adapters 2 = with Adapters only (6-packs) 3 = with Adapters & Pigtails (6-packs) 4 = with Adapters & Stub (6-packs) 5 = not applicable A = with Adapters only (8-packs) B = with Adapters & Pigtails (8-packs) C = with Adapters & Stub (8-packs) D = with Adapters only (12-packs) E = with Adapters & Pigtails (12-packs) F = with Adapters & Stub (12-packs) # of Fibers terminated: for example 012 = 12 fibers 024 = 24 fibers blank = not applicable Cable Type: Singlemode- A = pigtail, jacketed B = pigtail, buffered C = OFNR stranded D = OFNR ribbon E = Plenum stranded F = Plenum ribbon G = OSP stranded H = OSP ribbon Blank = not-applicable Pigtails: 1 = loaded with pigtails Stub Location: 2 = right 4 = left blank = not applicable Stub or Pigtail length (meters): 05 =5m 10 = 10m blank = not applicable COMPRESSION FITTINGS Compression fittings are utilized as an alternate method for securing cables to RPB and RPC enclosures. Compression fittings resist water pressure up to 70 psi. Polymer material resists salt water, weak acids, gasoline, alcohol, oil, greases and common solvents. Acme threads on the body prevent skipping, allowing for faster installations of lock nuts. Part # Description CF-(XX) Compression fitting Use first (XX) to specify size: 40 = Used for 24-fiber cable, 51 = Used for 36-fiber cable
40 FIBER MANAGEMENT & ACCESSORIES The Siemon Company offers a full range of accessories including Fiber Management Frames for mounting enclosures; Fiber Storage Centers for storing excess patchcord cable slack; Service Cables for splicing to OSP aerial cables; and Patchcords & Pigtails for performing inter- and cross-connections.
41 Users can also create a total end-to-end passive Fiber Management solution using The Siemon Company s LightWays Fiber Protection System (Ducting) [See LightWays Section for additional information].
42 6.2 FIBER MANAGEMENT & ACCESSORIES THE SIEMON COMPANY 23 INCH FIBER DISTRIBUTION FRAME The Siemon Company Fiber Distribution Frame provides a simple-to-manage, easy-toaccess system for mounting patch, splice, and storage enclosures. The frame features equal flange-style vertical channels which accommodate standard enclosures. The efficient design has 40 RMS capacity which accommodates up to ten (10) enclosures. The frame is supplied with Vertical Cable Managers (VCMs) that provide ample space to manage and retain up to 1440 patchcords. Fiber Distribution Frames have a steel frame with a durable beige finish. Vertical Cable Managers (VCMs) retain patchcords and provide easy installation and access Frame header includes three 5/8 in. (11mm) nuts for securing threaded rods to ladder racking or ducting Mounting holes in footer are included for anchoring frame to floor A lower horizontal trough provides patchcord storage and routing between frames, or within the same frame ANSI/EIA-310-D compliant Frames can be supplied: Un-assembled to maximize cost savings Assembled (channels, header, and footer) to reduce installation labor Assembled with Interbay (channels, header, footer, and Interbay Storage Panel) to maximize installation labor savings Dimensions: 7 ft. H x 23 in W x 12 in. D (2.1m H x 584mm W x 304.8mm D) Part # Description RK Unassembled; 7 ft. (2.1m) beige frame. Includes channels, header, footer, bottom trough, (18) Vertical Cable Managers RK-07A Assembled; 7 ft. (2.1m) beige frame. Includes channels, header, footer, bottom trough, (18) Vertical Cable Managers RK-07P Assembled 7 ft. (2.1m) beige frame, with Interbay Storage Panel. Includes channels, header, footer, bottom trough, (18) Vertical Cable Managers*, Interbay Storage Panel (installed on left side)* *Vertical Cable Managers (VCMs) are not assembled. They are attached after installation of enclosures. Note that the unique design enables fast attachment of each VCM via a single screw. Note: 1 RMS = 1.75 in. (4.5mm)
43 FIBER MANAGEMENT & ACCESSORIES 6.3 INTERBAY STORAGE PANEL & END GUARD Interbay Storage Panels are used to store excess patchcord fiber cables routed from enclosures located within a frame, or to an adjacent frame. Typically mounted between frames, Interbay storage panels provide an effective means of slack storage without occupying valuable space on the frame. Siemon End Guards are used at the end of a frame lineup and serve to protect the patchcords routed within and between the frames. End Guards also provide a means to mount outlets and switches. Interbay storage spools provide a means of neatly storing patchcord slack, while maintaining proper bend radius End Guard features hinged, removable door for easy access and protection to any accessories within Interbay Storage Panel Interbay Storage Panels can be installed alongside or between frames Lightweight and compact for easy additions to existing frames Storage spools maintain a 2 in. (50mm) bend radius throughout Nine 4 in. (100mm) deep storage spools provide ample space for storing patchcord slack Lower horizontal trough provides for patchcord storage and routing between frames, or within the same frame End Guard Hinged door can be easily removed to provide additional access For extra convenience, each End Guard has two thumb latch locks for ease of entry End Guard can be installed to hinge left or right Part # Description RK-P ft. (2.1m) Interbay Storage Panel, beige. Includes mounting hardware RK-G ft. (2.1m) End Guard, beige. Includes mounting hardware
44 6.4 FIBER MANAGEMENT & ACCESSORIES THE SIEMON COMPANY FIBER STORAGE CENTER Siemon s 3 RMS frame-mount Fiber Storage Center (FSC3) is typically utilized in tandem with a frame mount enclosure. Fiber patchcords exiting the front of an enclosure are routed into the FSC3 for storage of excess cable slack. The fiber management within the FSC3 is simple yet effective and is mounted to a tray that slides out the front of the cabinet to enable easy access to the coiled cable slack. The front and rear doors are easily removable by way of releaseable hinges and they can also be secured by installing a customer-supplied padlock through the hasps that are integral to the cabinet. Part # Description FSC Fiber Storage Center, 3 RMS, beige height: 5.25 in. (133mm) width: in. (432mm) depth: in. (380mm) Note: 1 RMS = (1.75 in.) 44.5mm FSC3 shown mounted in tandem with RPA enclosures FSC3 shown with storage tray slid out to access stored cables
45 FIBER MANAGEMENT & ACCESSORIES 6.5 SERVICE CABLES Service Cables are typically spliced to an aerial fiber trunk cable and fastened to an aerial mounted enclosure (amplifier, converter, transmitter/receiver) via the included fitting. The pre-terminated connectors are mated to adapters located inside the enclosure. 2-, 4-, and 6- fiber versions are available and all connectors are 100% tested for both insertion loss and return loss. A rugged waterproof fitting is supplied standard with each Service Cable. OPTICAL PERFORMANCE LIMITS Polish Type UPC APC Max. Insertion Loss (db) 0.5 db (0.25 Typical) Min. Return Loss (db) Legend (Return Loss performance level): UPC = Ultra PC (Physical Contact) APC = Angled PC (Physical Contact) ORDERING INFORMATION FP2 _ D- SCU - _ 01_ Fiber Count: 2 = 2 Fibers 4 = 4 Fibers 6 = 6 Fibers Connector type: FC = FC LC = LC SA = ST SC = SC Length: (meters) 01 =1m 02 =2m etc. Polish type: U = Ultra (UPC) A = Angled SC (SC/APC) N = Angled FC (Narrow Key) (FC/APC-N) W = Angled FC (Wide Key) (FC/APC-W)
46 6.6 FIBER MANAGEMENT & ACCESSORIES THE SIEMON COMPANY PATCHCORDS & PIGTAILS The Siemon Company offers patchcords and pigtails in any length, and with a variety of connector types for inter-connecting or cross-connecting fibers. Connectors are available polished to deliver either UPC or APC performance. Each terminated connector is optically tested for both insertion loss and return loss, assuring that 100% of these cable assemblies meet the stringent performance requirements of Telcordia Technologies GR-326-CORE, Issue 3. Additionally, The Siemon Company maintains a certification level to Telcordia Technologies SR All products are manufactured using the finest quality, precision zirconia ceramic ferrules and OFNR riser grade fiber cable. OPTICAL PERFORMANCE LIMITS Polish Type UPC APC Max. Insertion Loss (db) 0.5 db (0.25 Typical) Min. Return Loss (db) Legend (Return Loss performance level): UPC = Ultra PC (Physical Contact) APC = Angled PC (Physical Contact)
47 FIBER MANAGEMENT & ACCESSORIES 6.7 ORDERING INFORMATION PATCHCORDS (JUMPERS) FJ1 R - SCU SCU - 01 Fiber Count: 1 = 1 Fiber (simplex) 2 = 2 Fibers (duplex) Connector type: FC = FC LC = LC SA = ST SC = SC (See interface order chart) Length: (meters) 01 =1m 02 =2m etc. Cable type: R = Round duplex Blank = Jacketed simplex Polish type: U = Ultra (UPC) A = Angled SC (SC/APC) N = Angled FC (Narrow Key) (FC/APC-N) W = Angled FC (Wide Key) (FC/APC-W) Interface Order Chart End A End B End A End B FC FC SA SA FC LC SA SC FC SA SC SC FC SC LC LC LC SA LC SC PIGTAILS FP1 B - SCU - 01 Fiber Count: 1 = 1 Fiber (simplex) 2 = 2 Fibers (duplex) Connector type: FC = FC LC = LC SA = ST SC = SC Length: (meters) 01 =1m 02 =2m etc. Cable type: R = Round duplex B = Buffered fiber Blank = Jacketed simplex Polish type: U = Ultra (UPC) A = Angled SC (SC/APC) N = Angled FC (Narrow Key) (FC/APC-N) W = Angled FC (Wide Key) (FC/APC-W)
48 7.1 WORK GLOSSARY AREA Adapter Used to connect or join two connectors. Also sometimes referred to as a coupling. APC Angled Physical Contact. A connector designed with an 8 angle at the end of the ferrule. Return Loss Performance = 65 db minimum. Note: APC connector interface improves connector performance by maximizing Return Loss. Attenuator A passive device used to reduce the signal strength in a system. Available in many different mounting configurations. BER Bit Error Rate Bend Relief Boot Refers to the support unit just behind the connector, designed to prevent sharp bends in the fiber. Also called strain relief or boot. Buffered Fiber An un-jacketed cable. It consists of a coated fiber surrounded by a 900 micron diameter buffer. CO Central Office Cladding The lower refractive index material that surrounds the fiber core and provides optical insulation and protection. Cleave The controlled breaking of a fiber so that its surface is smooth. Coating Protective layer of material deposited onto the cladding portion of an optical fiber. Connector A mechanical device used to join and align two fibers together and to provide a means for decoupling the fibers. Coupler A fiber optic device used to couple light from one fiber into another fiber or to divide power between several fibers. db The abbreviation for decibel, which is the standard unit used to express signal gain or loss. Dispersion A measure of the frequency dependence in transmittance. Also called pulse spreading, since dispersion causes a broadening of the input pulses along the length of the fiber. Two major types of dispersion are modal and material. Can be caused by multiple frequency components having different propagation characteristics, or the relationship between the refractive index and wavelength or frequency. One of the limits on bandwidth. Dispersion Shifted Fiber A singlemode fiber that has zero dispersion wavelength at 1550 nanometers. Dispersion Unshifted Fiber A singlemode fiber that has zero dispersion wavelength at 1300 nanometers. Often called conventional or unshifted fiber. Duplex Cable Cable with two fibers. DWDM Dense Wavelength Division Multiplexer. Same as WDM except more wavelengths can be accommodated. Ferrule A component with a precise capillary which holds a fiber in place and aids in its alignment. The typical ferrule has an OD of 2.5mm, and a capillary of about 126 microns. Singlemode versions normally carry tolerances on OD, ID and concentricity of one micron or less. The material of choice since the late 80s has been tetragonal zirconia with a grain size less than 0.5 microns. FDF Fiber Distribution Frame Fiber A single, separate optical transmission element characterized by a core and cladding, with an outside diameter of 125 microns. Fiber Curl This is a term that has become useful for describing what happens to a fiber when there is misalignment in a mass or ribbon splicing joint. In this case the fiber(s) curl away from the joint to take up the slack or stress caused by misalignment of fiber lengths at the joint. FMS Fiber Management System. Fresnel Reflection The reflection of light from an optical discontinuity. For instance, in the common unterminated, unangled fiber end return loss will be about db (the unterminated loss of non- APC connector). The APC performance is better due to the management of the loss via the angle of the plane between the glass and the air. Fusion Splice The joining of two fibers by heating and fusing (melting) them together. GHz Gigahertz. One billion hertz. Gigabit Transmission of one billion of bits per second; Gbps. Hertz (Hz) A measure of frequency as defined in units of cycles per second. Index of Refraction The ratio between the speed of light in a vacuum and lights speed in a referenced medium. Index Matching Material A material, usually a liquid, gel, paste or film, whose index of refraction matches the fiber glass used for the fiber. It is used at the end face of the fiber to reduce Fresnel reflections. Insertion Loss The attenuation (loss) of power at a connector interface, expressed in db. Intrinsic Loss The theoretical minimum loss that a given device will have as a function of its nature, inherent to the variables of the manufacturing process. This term is also used to describe the theoretical minimum loss that a splice joint, coupler, or splitter will exhibit. Jacket (Sheath) The outermost segment of a fiber optic cable, generally a plastic material. Jacketed Cable Buffered fiber protected with a strength member, such as Aramid Yarn (Kevlar ), and an outer jacket. Jumper A length of cable with a connector terminated at both ends. Also called a patchcord. Kevlar The material used as the strength element in cable. Developed and trademarked by DuPont.
49 7.2 Kilometer One thousand meters (3,281 feet). Laser Light Amplification by Stimulated Emission of Radiation. A device that produces coherent light with a narrow range of wavelengths. Loss Synonymous with attenuation. A loss of power, measured in decibels; i.e. not fused. Loose Tube A protective polymer tube, often filled with a gel, used to contain one or more fibers. Meter A metric unit of measure that equals inches. MHz Megahertz, one million hertz. MIC Media Interface Connector. This is a pair of fiber optic connectors that link the fiber media to the FDDI or other cable. The MIC consists of both the plug terminated to a optical cable and the receptacle which is contain within the FDDI node. Microbending Loss Loss due to microscopic bends in the fiber. Micrometer One millionth of a meter; equivalent to micro-inches. Also, see micron. Micron (µm) Micrometer One millionth of a meter (39.37 microinches). Multi-Fiber Cable A cable with three or more fibers. Multiplexing The combination of two or more signals from two or more channels into a single output. Nanometer One billionth of a meter; equivalent to microinches. OTDR Optical Time Domain Reflectometer. A device that measures distance to a reflective surface by measuring the time it takes for a lightwave pulse to reflect from that surface. PC Physical Contact. The term used to describe connectors that allow the ends of the fiber to make contact (within an adapter). Patchcord A length of cable with a connector terminated at both ends. Also called a jumper. Pigtail A length of cable with a connector terminated at one end only. Reflection Also called Back Reflection. The abrupt change in direction of a light beam at an interface between two dissimilar media so that the light beam returns into the medium from which it originated. Reflection from a smooth surface is termed specular, whereas reflection from a rough surface is termed diffuse. The higher the associate value, the better the performance expressed in db. Also, see Return Loss. Refraction The bending of a beam of light through an interface between two dissimilar media or in a medium whose refractive index is a continuous function of position (such as graded-index fiber). Return Loss Same as Reflection except the sign of the wave is positive. The amount of power reflected back into the source. The greater the return loss the better the performance. Expressed in db. SC Connector A plastic, rectangular connector body with a 2.5 millimeter diameter ceramic ferrule. The connector utilizes a push/pull snap-in concept. Service Cable A cable that connects an incoming or feeder signal to the premises. Can be used to describe the connection to a customer s premise, or the inter/intra facility multi-fiber connection from the outside plant to a headend. Simplex Cable Cable with only one fiber. Singlemode (SM) Optical fiber designed to propagate only one mode. Components associated with this type of fiber require much tighter alignment tolerance than multimode (MM) fiber and, as a result, are more expensive. Cable color code associated with singlemode fibers is yellow. Source A light emitting diode (LED) or LASER diode (LD) that emits optical signals into the fiber network in response to an electrical signal input. Splice, Fusion Permanent joining of fiber ends (without a connector) by heating and fusing them together. Splice, Mechanical The joining of two fibers by a mechanical method (e.g. crimped, clamped or epoxied). Splitter Also know as a coupler. ST Connector A metal or plastic connector with a 2.5 millimeter diameter ferrule. The connector utilizes a bayonet style, twist-lock coupling method. Transceiver A device that combines both functions of the transmitter and receiver, thereby providing both output and input interfaces. UL Underwriters Laboratories. UPC Ultra Physical Contact. The term used for enhanced Return Loss Performance (55dB minimum). Wavelength The distance, especially on an electromagnetic wave, that a wave travels in the time it takes to oscillate through a complete cycle. Wavelengths of visible light are measured in nanometers or microns. Wavelengths, 1310 and 1550nm These wavelengths, measured in nanometers, are the most popular wavelengths in telecommunication systems sources. WDM Wavelength Division Multiplexer. A combination of two or more optical signals at different wavelengths, transmitted over a common optical path, usually a single fiber. Zero Dispersion Slope The value of the chromatic dispersion slope at the fiber s zero dispersion wavelength. Zero Dispersion Wavelength The wavelength at which the fiber s chromatic dispersion equals zero.
50 GLOSSARY THE SIEMON COMPANY METRIC CONVERSION CHART English-to-Metric Metric-to-English DISTANCE To convert: Into: Multiply by: To convert: Into: Multiply by: Inches (in.) Millimeters (mm) 25.4 Millimeters (mm) Inches (in.) Centimeters (cm) 2.54 Feet (ft.) Meters (m) Feet (ft.) Centimeters (cm) Centimeters (cm) Inches (in.) Meters (m) Feet (ft.) Yards (yd.) Centimeters (cm) 91.4 Meters (m) Feet (ft.) Meters (m) Yards (yd.) Miles (mi.) Kilometers (km) Kilometers (km) Miles (mi.) WEIGHT To convert: Into: Multiply by: To convert: Into: Multiply by: Ounces (oz.) Grams (gm) Grams (gm) Ounces (oz.) Kilograms (kg) Pounds (lb.) Pounds (lb.) Kilograms (kg) Kilograms (kg) Pounds (lb.) FORCE To convert: Into: Multiply by: To convert: Into: Multiply by: Foot Pounds (lb-ft) Newton Meters (N-m) 1.36 Newton Meters (N-m) Foot Pounds (lb-ft) TEMPERATURE To convert: Into: Multiply by: To convert: Into: Multiply by: Fahrenheit ( F) Celsius ( C) 0.56, then subtract 18 Celsius ( C) Fahrenheit ( F) 1.8, then add 32 VOLUME To convert: Into: Multiply by: To convert: Into: Multiply by: Quarts (qt.) Liters (L) Liters (L) Quarts (qt.) Gallons (gal.) Liters (L) Gallons (gal.) 0.264
51 CONTACT INFORMATION The Siemon Company Watertown USA Siemon Business Park 76 Westbury Park Road Watertown, CT USA Tel: (1) Customer Service Direct: Tel: (1) Fax: (1) The Siemon Company: The Siemon Company is a technology leader and world-class manufacturer of high quality, high performance structured cabling systems for voice, data, and imaging. Over 300 active patents reflect The Siemon Company s focus on structured cabling and its global commitment to value-added innovation. The Siemon Company end-user customers span the globe and include many of the world s leading Commercial and Industrial Organizations, Universities, Hospitals, Airlines, Financial Institutions, Governments, CATV Companies, MSOs, CLECs, IXCs, PTTs, Independent and Regulated Telephone Companies. The Siemon Company Web Site: Our web site is divided into several key areas (here are a few) Homepage Features the latest in updates on products and systems, technical articles, standards overview, and more. e-catalog e-catalog uses the latest internet search technology to help you find the right products you need quickly and easily. About The Siemon Company Includes company history, and information about facilities, engineering, quality assurance, etc. Products & Applications System Warranty Network Cabling Standards Programs Certified Installers SM, Consultant/Architect and Project Assistance References Press Releases, Siemon Success Stories, Technical Articles Support Contact Us
52 All Fiber Management Systems are NOT alike! Take a closer look at Siemon s LightWays System Quick-Pack Adapter Panels!! Modular Versatility! One finger is all it takes to remove or add a Siemon Quick-Pack adapter panel. Siemon s unique integrated latches don t snag cables and make cleaning access a snap. Bend Radius Control Inside and Out! Siemon s LightWays enclosures accommodate pigtail modules, splitter modules, plug and play modules, and Quick-Packs for easy ordering and minimal inventory. Easy Access! Bend Radius Guides and recessed Quick-Pack adapter panels ensure that minimum bend radius is always maintained both inside and outside of LightWays enclosures. Easy-access adapter bezels make cleaning and administration quicker and easier. Just squeeze for quick installation and removal No twisting and turning required. LightWays 2000 The Siemon Company Siemon Business Park 76 Westbury Park Road Watertown, CT USA C00-TELCOCATV, Rev. A 5/00
Reliable, Consistent, Quality
Reliable, Consistent, Quality 1-877-320-3143 www.fibertronics.com Reliable, Consistent, Quality Welcome To Fibertronics Inc. Reliability, consistency, and quality is what we put behind every Fiber optic
Pretium Connector Housings
Pretium Connector Housings A LANscape Pretium Solutions Product Applications Main cross connect, intermediate cross connects and telecommunications rooms Rack or equipment cabinet installations Data center
FiberGuide Fiber Management Systems. 4th Edition
FiberGuide Fiber Management Systems 4th Edition Table of Contents Introduction Introduction...1 A Variety of Solutions...2 Innovative Products...3 Features and Benefits... 4 Applications Combining System
FCS-FCT-FCP Housings and Connector Panels. InfiniCor SX+ OM3, InfiniCor 600 OM2, InfiniCor 300 OM1, SMF 28e OS1/OS2
Product Family: Product: Fibre: LANscape Hardware Solutions FCS-FCT-FCP Housings and Connector Panels InfiniCor SX+ OM3, InfiniCor 600 OM2, InfiniCor 300 OM1, SMF 28e OS1/OS2 Applications Corning Cable
FDC Hardware Product Family
FDC Hardware Product Family Introduction Corning Cable Systems designed the original FDC product family to organize and manage high fiber count cross-connect and interconnect installations, primarily in
Patch Cords for Data Center Applications
Applications General use of patch cords includes the interconnection of the optical fiber cable plant with opto-electronic equipment, and/or the cross-connection between cable plant segments. Pigtails
Plug - Type (Male/Female) Attenuators CAA series Singlemode
Plug - Type (Male/Female) Attenuators CAA series Singlemode Description: The plug-type singlemode attenuators are used directly on the ends of fiber optic jumpers prior to installation in adapters. These
1. Furnish and install faceplate and modular jacks at each single gang outlet as described below:
Washington University in St. Louis Building: Communication Specification: Research Voice/Network/Typical 1. Furnish and install faceplate and modular jacks at each single gang outlet as described below:
Fiber Plant Design Considerations for Active DAS Mike Brownson VP DAS Technical Solutions Hutton Communications
Fiber Plant Design Considerations for Active DAS Mike Brownson VP DAS Technical Solutions Hutton Communications Topics! Understanding Fiber Types! Powering your Remotes via Composite Fiber! Fiber Design
FACT OPTICAL DISTRIBUTION FRAME SYSTEM
Fiber Connectivity for Splice/Patch and Patch/Patch For almost 30 years, CommScope has led the industry with solutions such as FIST fiber management system, providing a system of fiber management from
Pretium EDGE HD Solutions
Pretium EDGE HD Solutions for Enterprise Data Centers and Storage Area Networks Corning Cable Systems Pretium EDGE HD Solutions create a fiber optic tip-to-tip solution for Data Centers and Storage Area
7.4 3M No Polish Connector
Cap Fibre Splice Element Description 3M No Polish Connector (NPC) enables fast, on-site installation of 250μm and 900μm connections utilizing a one piece, pre-assembled design. The SC compatible connector
1U Multi-Function Fibre Enclosure
FEATURES AND SPECIFICATIONS Features and Benefits The is a configurable rack mount unit for storing and terminating incoming fibre cable. The fibre enclosure has been designed to accommodate various termination
Managing High-Density Fiber in the Data Center: Three Real-World Case Studies
Managing High-Density Fiber in the Data Center: Three Real-World Case Studies CHALLENGE In today s data center, fiber optic links have become more vital than ever for transmitting data to and from a large
Cabinets 101: Configuring A Network Or Server Cabinet
Cabinets 101: Configuring A Network Or Server Cabinet North, South and Central America White Paper May 2012 www.commscope.com Contents Background Information 3 What is a network or server cabinet? 3 What
Cable Assembly Solutions at the Speed of Light
Cable Assembly Solutions at the Speed of Light Peggy Kovling ACI Founder Peggy Kovling credits her extensive knowledge of the cable business, along with her abilities in customer relationship management,
Table of Contents. Fiber Trunking 2. Copper Trunking 5. H-Series Enclosures 6. H-Series Mods/Adapter Panels 7. RSD Enclosures 8
Data Center Guide 1 Our Philosophy As a leader in the enterprise cable industry since our inception over three decades ago, we can help you implement the solution that will work best for your cabling infrastructure,
Multiple Solutions for Connecting Multiple Dwelling Units (MDUs) WHITE PAPER
Multiple Solutions for Connecting Multiple Dwelling Units (MDUs) WHITE PAPER Multiple Solutions for Connecting Multiple Dwelling Units (MDUs) Abstract Fiber-to-the-Premises (FTTP) networks increasingly
FTTX Solutions FDH 3000 Cross-Connect
TE Connectivity's (TE) FTTX infrastructure solutions are designed from the ground up to meet the unique requirements of FTTX networks. Designed for operational efficiency and scalability, TE s FTTX solutions
LANC Fibre Patch Panel Solution
features and benefits Modular front with interchangeable fibre optic adapter modules Quick mount feature (teardrop design) Port numbers printed above and below adapter modules High-density using LC connectivity
BIX Cross-Connect System Distribution Connectors, Multiplying Connectors and Modular Jack Connectors
C O M M E R C I A L N E T W O R K I N G C O P P E R 15.13 Distribution Connectors, Multiplying Connectors and Modular Jack Connectors A0393146 QCBIX1A4 Connector BIX Distribution Connector The BIX Distribution
InstaPATCH ZERO Solution Guide
SYSTIMAX Solutions InstaPATCH ZERO Solution Guide Rapid Server Deployment and Change Management North, South and Central Americas 1 As data centers face ever-increasing IT demands, growth demands and evolving
Secure your IT equipment with confidence... secure with NetClosure
Secure your IT equipment with confidence... secure with NetClosure SERVER CABINETS NetClosure s REM Series Server Cabinet is the ultimate solution designed and engineered for demanding data center environments.
Fiber Optic Cable Assemblies. Pigtails, Jumpers (simplex and duplex), Fanouts, Pre-connectorized Multi-Fiber Cable
Fiber Optic Cable Assemblies Pigtails, Jumpers (simplex and duplex), Fanouts, Pre-connectorized Multi-Fiber Cable 1 Cable assemblies used in patch panels (Fiber Distribution Units) are an essential interface
DIRECTIONAL FIBER OPTIC POWER MONITORS (TAPS/PHOTODIODES)
Features: DIRECTIONAL FIBER OPTIC POWER MONITORS (TAPS/PHOTODIODES) PATENT NUMBERS: CANADA 2,494,133, USA 7095931, 7295731 AND CHINA 1672073 Telcordia GR-468 qualified Available in versions for any wavelength
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE
Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS
Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS STANDARD & ECONOMICAL BasicRack A complete low-cost, high-quality basic equipment management system. Design Six web channel holes per side allow
Reduced depth High Density Cabinet HDC with 19 swing frame 36, 40 and 45 U
Reduced depth High Density Cabinet HDC with 19 swing frame 36, 40 and 45 U Applications The High Density Cabinets are suitable for Central Offices and can be used as fiber nodes and termination points
Versatile, Scalable Cable Protection in Data Centers and Central Offices
APPLICATION GUIDE FOR FIBERR UNNER CABLE ROUTING SYSTEM Versatile, Scalable Cable Protection in Data Centers and Central Offices PANDUIT is a Technology Developer Partner for Storage Networking Hardware.
Cable Routing System Versatile, Scalable Cable Protection in Data Centers and Central Offices
Application Guide For FiberRunner Cable Routing System Versatile, Scalable Cable Protection in Data Centers and Central Offices Panduit is a Technology Developer Partner for Storage Networking Hardware.
FOCONEC. Network Connectivity & Cabling Management. Overview: Features: Brighter Future
CORDS & CABLE ASSEMBLIES Standard Simplex/Duplex Patch Cords Overview: FOCONEC supplies full series of standard simplex, duplex patch cords or pigtails, designed for interconnection or cross connection
SECTION 25110 TELECOMMUNICATION ROOMS
PART 1 - GENERAL 1.1 SUMMARY A. SCOPE SECTION 25110 TELECOMMUNICATION ROOMS 1. This section includes the minimum installation requirements for equipment and cabling infrastructure in Telecommunication
ETD Fiber Optic Products
ETD Fiber Optic Products ETD manufactures and supplies a wide range of passive fiber optic components and solutions for the European Data, Telecom and FTTX environment. ETD has worked in the Fiber Optic
Cabinet V800 V800 CABINETS
V800 Cabinet Siemon s V800 cabinets provide a robust, cost-effective enclosure solution that provides valuable Zero-U space on each side of the equipment rails for cable management, PDU mounting or connectivity
Belden. Optical Fiber Catalog. One Enterprise. One Infrastructure. One Partner. Belden IBDN FiberExpress Systems
Belden Optical Fiber Catalog One Enterprise. One Infrastructure. One Partner. Belden IBDN FiberExpress Systems With the IBDN FiberExpress Systems, Belden takes a complete approach to fiber optic cabling.
Plug & Play Universal Systems
Plug & Play Universal Systems A LANscape Pretium Plug & Play Universal Systems for Data Centers and Storage Area Networks (SANs) Corning Plug & Play universal systems create a fiber optic tip-to-tip solution
INTELLIGENT INFRASTRUCTURE MANAGEMENT
F/ System F/ Assemblies, 9.0 W W W. S I E M O N. C O M SECTION CONTENTS System...............................9. IM Software........................... 9. Analyzers..............................9. System
Faster Method for Connecting Customers in the Colocation Data Center
Faster Method for Connecting Customers in the Colocation Data Center The increased demand for datacenter space is creating both opportunities and challenges for providers of colocation space. Among these
19" Data Racks. Adjustable feet To compensate for uneven floors and assure great stability all feet can be up to 20 mm adjusted.
19" Data Racks Attractive design and high quality are characteristic. Basic framework is welded from multiple bent metal plate, which assures great rigidity suitable for heavier equipment. All profile
Universal MATE-N-LOK Connectors
Product Facts Pins and sockets can be intermixed in the same housing Positive polarization Rear cavity identification completely enclosed in housings Positive locking housings Insulation capability to.00
ADC Structured Cabling Solutions
ADC Structured Cabling Solutions The highest performing cross-connect system in the world HighBand Wall Mount Patching Solution Reliable, secure and cost effective ADC s HighBand cross connect solution
Rack installation instructions
Rack installation instructions Review the documentation that comes with the rack cabinet for safety and cabling information. Before you install the server in a rack cabinet, review the following guidelines:
Mini USB and USB 2.0-IP67 Connector System
Mini USB and USB 2.0-IP67 Connector System Section 12 Mini USB and USB 2.0-IP67 Connector System CONEC has added the Mini-USB connector. This Mini-USB IP67 receptacle and plug family, feature a bayonet
Customized Server Cabinets
GOING GREEN WITH CUSTOMIZABLE CABINETS AND RACKS Designed to provide industry leading airflow, CyrusOne s cabinets and rack solutions promote optimal cooling and contribute to reduced power consumption.
ADC-APC Integrated Cisco Data Center Solutions
Advanced Infrastructure Solution for Cisco Data Center 3.0 Ordering Guide ADC-APC Integrated Cisco Data Center Solutions The evolution of data centers is happening before our eyes. This is due to the
SECTION 27 05 36 CABLE TRAYS FOR COMMUNICATIONS SYSTEMS
SECTION 27 05 36 CABLE TRAYS FOR COMMUNICATIONS SYSTEMS PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary to perform and complete such
fiberopt Whirlwind Fiber Optic Solutions product guide 1-800- 733-9473 99 Ling Rd. Rochester, NY 14612 whirlwindusa. com
fiberopt Whirlwind Fiber Optic Solutions product guide 1-800- 733-9473 99 Ling Rd. Rochester, NY 14612 whirlwindusa. com OpticalCON DUO, QUAD and ADAPTER CABLES 1 2 OC-4-OQ-OQ-0-050 OC-2-M50-OD-SC-0-005
SECTION 27 13 24 COMMUNICATIONS OPTICAL FIBER OSP CABLING
SECTION 27 13 24 COMMUNICATIONS OPTICAL FIBER OSP CABLING PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary to perform and complete
Cable Assemblies. Corning Cable Systems
Corning Cable Systems OptiFit Node Assembly Photo CAPSS1721 Description As the industry s leading supplier of single-mode cable assemblies, Corning Cable Systems offers the most complete line of connectors
Cable Tie Mounting Bases
Temperature Rating: 0ºC to 66ºC (32ºF to 150ºF) *Synthetic Rubber Adhesive Choose from adhesive-backed, epoxy or screw mounting bases! Available in a variety of materials for both indoor and outdoor use
INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks
Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 [email protected] in door opening solutions INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate
FIBER OPTIC AND COMMUNICATION PRODUCTS
FIBER OPTIC AND COMMUNICATION PRODUCTS Photonic Products Cable Assemblies Termination Boxes & Hardware Data Center FTTH World Wide Supplier #11 Test Equipment Ethernet Products Solutions for Telecommunications
SECURE Fiber Optic Products
SECURE Fiber Optic Products LC SECURE Fiber Optic Products (Pages 9 and 10) LC SECURE Connectors, Cable Assemblies and Adapters MPO SECURE Fiber Optic Products (Pages 11 and 12) MPO SECURE Cable Assemblies
Developing the Green Data Center
Products and Solutions to Support Energy Efficiency Ordering Guide Table of Contents Developing the Green Data Center Introduction...5 Airflow Management in the Data Center...6 Angled Panels Glide Cable
SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design
SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design Ideal installation for; Offices Branch Offices Schools Computer Aided Classes Government Offices Hotels
Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes
CANTEX INC. 301 Commerce Ste 2700 Fort Worth, Texas 76102 817-215-7000 Fax: 817-215-7001 Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes YOUR FULL
CORNING CABLE SYSTEMS GENERIC SPECIFICATION FOR TIGHT BUFFER OPTICAL FIBER CABLES FOR INTER- AND INTRABUILDING APPLICATIONS.
CORNING CABLE SYSTEMS GENERIC SPECIFICATION FOR TIGHT BUFFER OPTICAL FIBER CABLES FOR INTER- AND INTRABUILDING APPLICATIONS September 2006 Revision 7 Corning Cable Systems reserves the right to update
Discontinued. Volition. Fiber Optic Cable. 3Innovation
Volition Fiber Optic Cable Tough enough to take it. Easy to handle. The Volition Network Solution from 3M includes horizontal and backbone cable with 62.5/125 µm and 50/125 µm multimode fiber, and 9/125
TCTC Cabling Specifications
TCTC Cabling Specifications Purpose: To provide a standard specification that will be used for all Tri County Technical College (TCTC) facilities requiring structured cabling installation. Product specifications,
ADC s Data Center Optical Distribution Frame: The Data Center s Main Cross-Connect WHITE PAPER
ADC s Data Center Optical Distribution Frame: The Data Center s Main Cross-Connect WHITE PAPER ADC s Data Center Optical Distribution Frame: The Data Center s Main Cross-Connect Introduction The primary
Cabling Services (price per pull) Zone 1 Zone 2 Zone 3 Zone 4 Zone 5
BryComm, LLC -SDD-1901 Cabling Services (per pull) - Labor Only STANDARD TIME The price per cable pull represents all labor to include fishing walls, running cable through modular furniture, terminating,
Fiber Optic. Passive Components Edition 2009
Fiber Optic Passive Components Edition 2009 Reliably connected to your network Your partner for system solutions The HUBER+SUHNER Group is a leading global supplier of components and systems for electrical
Cluster Box Units. (CBU s) 3300 Series CBU Door Sizes. Fully Integrated Parcel Lockers CLUSTER BOX UNITS FRONT LOADING. continued on pages 7-11
Cluster Box Units (CBU s) continued on pages 7-11 CLUSTER BOX UNITS FRONT LOADING Made of heavy duty aluminum and stainless steel hardware, Salsbury 3300 series U.S.P.S. approved Cluster Box Units (CBU
Intelligent Cable Management Systems
Intelligent Cable Management Systems Bringing Practical Application Karen Pearson - Leviton Why Cable Management Matters Performance Cooling and air-handling Maintenance ANSI/TIA 569* Telecommunication
electrics P OW E R E N T RY B A S I C S P OW E R & C O M M U N I C AT I O N S B A S I C S P OW E R D I S T R I B U T I O N B A S I C S
P RO D U C T M A P / TA B L E O F C O N T E N T S..................6 8 6 E L E C T R I C S & C O M M U N I C AT I O N S O V E RV I E W.............6 8 9 P OW E R E N T RY B A S I C S PA N E L - M O U N
PANDUIT is a Technology Developer Partner for Storage Networking Hardware. FIBER OPTIC CABLING SYSTEM SOLUTIONS B EYOND T HE G LASS
PANDUIT is a Technology Developer Partner for Storage Networking Hardware. FIBER OPTIC CABLING SYSTEM SOLUTIONS B EYOND T HE G LASS Bandwidth Requirements Push Fiber Optic Solutions Offices, Operations
PURE : REliable planning of data center cabling
PURE : REliable planning of data center cabling THE PURE EFFEct: TWICE AS MANY CONNEctionS AND 15 METERS MORE CHannEL LEngtH * PreCONNECT PURE is a milestone in the development of high-end IT cabling for
Keyed LC Connector Solution
features and benefits Eight color-coded mechanical key positions Meets TIA/EIA-568-B requirements Keyed connectors and adapters Full solution availability Keyed LC Connectors Photo LAN758 SPECIFICATION
CNC Tool Storage Solutions
CNC Tool Storage Solutions SOLUTIONS Thanks to the flexibility of the CNC line, your tools will be protected during regular handling, transportation and storage. The Rousseau CNC tool rack distinguishes
PS6500 Storage Arrays Rack Mount Instructions
PS6500 Storage Arrays Rack Mount Instructions Part Number: R724M Rev. A01 Copyright 2010 Dell, Inc. All rights reserved. Dell is a trademark of Dell, Inc. EqualLogic is a registered trademark. All trademarks
ATTACHMENT F 050R6800016 - CABLE AND WIRING SERVICES FUNCTIONAL AREA I PRICE PROPOSAL FORM Amendment 6
050R6800016 CABLE AND WIRING SERVICES (Column A) (Column B) (Column C) (Column D) (Column E) (Column F) (Column G) (B+C+D+E)*F= G Item Description PER 100' RUN PER 150' RUN PER 200' RUN PER 300' RUN QUANTITY
Cable Runways & Accessories
SB17U SB13AL SB17 SB17T SB117 SB17HRB SB2107 SB2101A SB17VRB SB2110A SB2129 SB2129SD SB130 SB2221 SB126 SB2118 SB119 SB2105 113 Cooper B-Line manufactures a wide variety of high quality cable pathway products
CABLE SUPPORT SYSTEMS
CABLE SUPPORT SYSTEMS eaturing the CADDY CAT HP J-Hook System Why CADDY CAT HP? Why Choose CADDY CAT HP over tray? ast and Easy to Install Much faster installation compared to conventional cable or ladder
Rack Systems Solutions
Rack Systems Solutions Designed to simplify cable management and improve power distribution Engineered by APC by Schneider Electric for Dell, NetShelter S is the next-generation rack enclosure solution
IT infrastructure Efficiency-boosting solutions. nextlevel. for data centre
IT infrastructure Efficiency-boosting solutions nextlevel for data centre 2 Rittal IT infrastructure The whole is more than the sum of its parts. The same is true of Rittal The System. With this in mind,
Category 6 Solutions. 4. Category 6 Solutions. 09/08 400836IN TrueNet Structured Cabling. Introduction... 4.2. Cable... 4.3. Patch Panels... 4.
Category 6 Solutions Introduction... 4.2 Cable... 4.3 Patch Panels... 4.4 Modules... 4.6 Patch Cords... 4.12 Outlets... 4.16 Faceplates...4.18 4. 1 Search Category 6 Solutions Introduction ADC KRONE s
3M One Pass Fiber Pathway
The Network of Networks 3M One Pass Fiber Pathway 3M One Pass Fiber Pathway is a horizontal cable pathway and drop cable solution installed simultaneously in one pass around a hallway perimeter Ideal for
Organizing and Managing Equipment Rooms
Organizing and Managing Equipment Rooms How you organize and maintain your equipment room can be just as important as maintaining the operating systems on the boxes themselves. Although many companies
HARTING Ethernet Cabling 8-poles Overview
Ethernet Cabling 8-poles Overview RJ45 Connectors [on page 8] System cables [on page 12] Distribution modules and Outlets [on page 17] Connectors [on page 20] System cables [on page 26] Panel feed-throughs
T1 Backhaul Connectivity Solution All Products :: Application Note
Telect 1 RU Customer Interface Panel (CIP) Enables Demarcation, Remote Circuit Maintenance and Trouble Isolation at the Backhaul Node The Application: T1 Demarcation and Testing in Backhaul Environments
DATA CENTRES POWERED BY EXCEL
DATA CENTRES POWERED BY EXCEL MAXIMISE EFFICIENCY BOOST PERFORMANCE INCREASE R.O.I. WITHOUT COMPROMISE Excel is a world-class premium performance end-to-end infrastructure solution. Designed, manufactured,
Cooktop Low-Profile Ventilation Hoods
INSTALLATION GUIDE Cooktop Low-Profile Ventilation Hoods Contents Wolf Cooktop Low-Profile Ventilation Hoods........ 3 Cooktop Low-Profile Hood Specifications.......... 4 Cooktop Low-Profile Hood Installation............
Cable Installation Accessories. Cable Hoisting and Attachment. Snap-In Hangers. SnapStak Hangers
SnapStak Hangers New design increases stack height SnapStak hangers have become the industry standard for maximizing space utilization on crowded towers and now that utility is further expanded with the
AMPSEAL* Automotive Plug Connector and Header Assembly
AMPSEAL* Automotive Plug Connector and Header Assembly Application Specification 24 SEP 97 Rev E All dimensions are given in millimeters unless otherwise specified. All dimensional tolerances are +0.2
1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications.
Issued 2005/06/01 Section 16743 Data System Page 1 of 7 PART 1 GENERAL 1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications..2 Data system equipment
Compaq Rack Options and Accessories. Monitors and Keyboards
1 Compaq Rack Options and Accessories Compaq offers a wide variety of rack options and accessories that help you to complete your 9000 and 10000 series racks. Monitors and Keyboards TFT5600RKM United States
Uniprise Solutions. Information Security Network Solutions
Uniprise Solutions Information Security Network Solutions Information Security Network Solutions Companies today face the challenges of maintaining data security throughout the enterprise. Network managers
Secure/Keyed LC System Solutions Overview
Secure/Keyed LC System Solutions Overview Designing performance and efficiency into your secure network Introduction In recent years, physically discrete fiber connection systems have emerged to respond
Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series
COMPONENTS PRODUCT INFORMATION RoHS Compliant NEW Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series Optical FO-BH Series (Compact Type) CONNECTOR
Section 21. Telecommunication Hardware. www.geindustrial.com BuyLog Catalog 21-1
Introduction...21-1 Fiber Closure Hardware...21-2 Cable Location Surge Protectors...21-4 Introduction GE has been manufacturing Telecommunication Hardware products for over 20 years and has become a leader
BLINK Triple-Play Connector
An innovative optical connector tailored to residential requirements forms the basis of the HUBER+SUHNER Fiber In The Home portfolio. Increased protection against soiling of the connector end surfaces,
3M FIBERDOME CLOSURE KIT FD08 Contains transition tray and one splice tray; capacity for three more splice trays.
MULTILINK Dome ENCLOSURE 3M SPLICE CASES This splice closure, designed in a dome configuration, supports up to 96 single fused fibers while maintaining a small footprint. Six cable ports allow for single
DIVISION 27 COMMUNICATIONS. A. System design shall be completed by a Registered Communications Distribution Designer (RCDD).
DIVISION 27 COMMUNICATIONS 27 00 00 COMMUNICATIONS A. System design shall be completed by a Registered Communications Distribution Designer (RCDD). B. Comply with American National Standards Institute
UT Southwestern Medical Center Information Resources Cable Installation Standard
UT Southwestern Medical Center Information Resources Cable Installation Standard PART 1- GENERAL 1.01 SUMMARY A. Furnish and install wire, cable, devices, equipment, and accessories for a complete system
ELECTRIC METERING COMMERCIAL & INDUSTRIAL
ELECTRIC METERING COMMERCIAL & 1.0 INDEX 1.0 INDEX 2.0 SCOPE 3.0 GENERAL REQUIREMENTS 4.0 METER LOCATIONS 5.0 UNDERGROUND TERMINATIONS 6.0 METERING TRANSFORMER ENCLOSURES 7.0 SINGLE CUSTOMER METER INSTALLATIONS
How To Set Up A Minipatch System For A Small Office Or Home Use
Issue : 4 Wood Communications Networking Products Catalogue Small Office & Home Solution Small Office / Home Solution Min LAN Comms Cabinets - Multimedia Panel - Soho Ethernet Switches - Multiroom Audio/Video,
Bulk Storage the OIL SAFE Way. Three System Types. Establish Best Practice
Bulk Storage the OIL SAFE Way OIL SAFE Bulk Systems are the most feature rich and highest quality lubricant storage and dispensing systems available. Fully Modular and ships ASSEMBLED Three System Types
SECTION O FIBER OPTICS
SECTION O FIBER OPTICS CONTENTS PAGE 1. GENERAL...O-2 1.1 Introduction...O-2 1.2 Definitions...O-2 1.3 Requirements...O-2 2. RUNNING, SECURING AND FIRESTOPPING FIBER OPTIC CABLE...O-3 2.1 Running Fiber