IN-SITU TESTING IN-SITU TESTS. Standart Penetration Test (SPT): In-situ Tests. Assist. Prof. Berrak TEYMUR

Size: px
Start display at page:

Download "IN-SITU TESTING IN-SITU TESTS. Standart Penetration Test (SPT): In-situ Tests. Assist. Prof. Berrak TEYMUR"

Transcription

1 IN-SITU TESTING IN-SITU TESTS Ait. Prof. Berrak TEYMUR Provide: alternative deign data in-itu propertie where unditurbed ampling i not poible Large volume of material Method: Standard Penetration Tet (SPT) Cone Penetration Tet (CPT) Preuremeter tet Dilatometer tet Other method (vane hear, permeability etc.) In-itu Tet 1- Standart Penetration Tet (SPT): 63.5kg hammer weight (Donut, afety,automatic trip hammer), 0.76m height, Totaly 45cm penetration through oil. Firt 15cm ignore, Blow # veru lat30cm. Ued primarily in granular oil Tet procedure may be found in ASTM D-1586, BS1377. Standart Penetration Tet (SPT): Advantage Varying diameter, Low cot, Widely ued, Experience. Limitation International tandart of variability of procedure Method of drilling and upporting the hole Hammer mechanim and rod ize ued The plit-poon geometry (minor effect) Method of teting Correction - overburden preure and PWP buildup Correction factor of blow number for fine and, ilty and, ilty oil under GWT ( N 15) N' =

2 SPT Empirical value for Dr and q u of granular and fine oil baed on SPT blow number Beide obtaining oil ample, SPT provide correlation; relative denity and friction angle N Clay Conitency Very oft Soft q u (kpa) < undrained hear trength direct etimate of ettlement Medium Stiff Very tiff >30 Hard >400 Sand & Silt CONE PENETRATION TEST State Very Looe Looe Medium Dene Dene N * (blow/ 300mm) < Friction angle, deg < Relative Denity (%) < The end reitance of the cone at any depth called the cone penetration reitance i (q c ) meaured. q c i the force required to advance the cone divided by the end area. Unlike the SPT, oil ample cannot be recovered during the CPT. Intrumented probe jacked into ground at contant rate of penetration (2cm/ec) Cone reitance (q c ) and leeve friction (q ) meaured cone reitance (q c ) correlate with trength, and friction ratio (q /q c) with material type Should alway be correlated with borehole information Very dene >50 > ASTM D-3441, BS 1377 (Part 9) 2

3 CONE PENETRATION TEST Applicable Soft clay Fine to medium coure and Not Applicable Very tiff clay Hard clay Gravel 60 cone, 10cm 2 bae area, 150cm 2 friction leeve, 10-50mm long ample collection. Advantage CONE PENETRATION TEST Limitation Repeatable and reliable No ample, data, Correlation with CPT are le, Fater and cheaper, Le experience, Continuou data profile. Drainage condition i unknown. CONE PENETRATION TEST Type of cone: Mechanical cone (Dutch cone - reading every 200 mm)- The tip i connected to an inner et of rod and it i firt advanced about 40mm giving the cone reitance. With further thruting, the tip engage the friction leeve. Electrical cone (contant reading)-the tip i attached to a tring of teel rod. It i puhed into the ground at the rate of 20mm/. Wire from the tranducer are threaded through the centre of the rod and continuouly give the cone and ide reitance. Electrical piezocone Seimic cone Friction Ratio : F R < 1% :and, F R > 5% :clay F R = q q c CONE PENETRATION TEST.100 Ued for deign of pile and to etimate the bearing capacity and ettlement of foundation. 3

4 Parameter Determination(Sand) Baed on Meyerhof (1965) Parameter Determination(Clay) q c, MPa < State Very Looe Looe Med dene Dr (%) < Friction angle, deg < Approximate relationhip c u = (q c p)/n k q c = cone reitance p = total over-burden preure Dene N k = for NC clay >20 Very dene = for OC Clay CONE PENETRATION TEST Data collected during electrical CPT q C q S F R u (Mpa) (kpa) (%) (kpa) PC: q C can be correlated to : φ,d r,c U, N 4

5 CPT-Related Webite The Liquefaction Site (and CPT ite): Link page to manufacturer, upplier, and CPT ervice: Liting of available video on CPT and other in-itu tet: The book Cone Penetration Teting in Geotechnical Practice (Lunne, Roberton, & Powell, 1997) THE PRESSUREMETER TEST The Preuremeter tet i an in-itu tet developed by Menard in Applicable for : oft clay, fine to medium and. The preuremeter i a cylindrical device deigned to apply a uniform radial preure to the ide of a borehole in which it i placed. There are two different baic type: The Menard preuremeter which i lowered into a preformed borehole The Self-boring preuremeter which form it own borehole and thu caue much le diturbance to the oil prior to teting THE PRESSUREMETER TEST In both cae, the preuremeter tet involve the application of known tree to the oil and the meaurement of the reulting oil deformation. The ide of the borehole are loaded by preuriing a fluid contained within a flexible rubber membrane. THE PRESSUREMETER TEST (MPT) The device conit of three part (top, cell and bottom) a hown below: The expanion of the cavity i determined either by meauring the volume of fluid needed to preurie the membrane and/or by meauring the movement of the oil at the cavity wall uing lvdt (diplacement tranducer). Generally, preuremeter are deigned for maximum inflation preure in the range MPa in oil and MPa in very tiff oil and weak rock. E and K 0 can be determined. Bowle,

6 Meauring Cell Volume (V) V 0 THE PRESSUREMETER TEST Zone 1 Reloading Zone 2 Peudo Elatic zone Zone 3 V Platic Zone P Zone 1: Soil puhed back to initial tate Zone 2: Peudo elatic, V v P i linear Zone3: Platic Zone THE PRESSUREMETER TEST Alo, the relationhip between E and G i given by E = 2 (1 + µ ). G Vo p G = V P o Meauring Cell Preure (p) For Zone 2 : 2 (1+ µ ) Vo p where E : Young Modulu E = of oil µ : Poion ratio V V o : Volume correponding to beginning of zone 2 at p o p/ V = 1 / (lope of line in zone 2) Preuremeter tet reult can alo be ued to determine the at ret earth preure coefficient ; Ko = P o σ ' Note:In France, hallow and deep foundation deign i all baed on preuremeter tet. FIELD VANE TEST The vane hear tet may be ued during the drilling operation to determine the in-itu undrained hear trength (c u ) of clay oil, particularly oft clay. The vane hear apparatu conit of four blade on the end of a rod. The height, H of the vane i twice the diameter, D. The dimenion of vane are; D=38.1mm, H=76.2mm, 1.6mm thick blade and 12.7mm diameter of rod. Thi tet i performed every 0.75 to 1 m of depth. FIELD VANE TEST The vane of the apparatu are puhed into the oil at the bottom of a borehole without diturbing the oil appreciably. Torque i applied at the top of the rod to rotate the vane at a tandard rate of 0.1º/ec. Thi rotation will induce failure in a oil of cylindrical hape urrounding the vane. The maximum torque, T applied to caue failure i meaured. 6

7 H FIELD VANE TEST where 2 3 D H ad T = cuπ H = 2 D 2/3 : uniform end hear a = 3/5 : parabolic end hear 1/2 : triangular end hear FIELD VANE TEST When ; H/D= 2 & a=2/3 T c u = D ( c ) = λ ( c ) 1,2 u deign u field T : Nm f(c u,h,d) D are rapid, economical and extenively ued give good reult in oft and medium-tiff clay error can occur due to poor calibration of torque meaurement and damaged vane correlation with preconolidation preure and OCR exit λ 1,0 0,8 0,6 0,4 0 PI % 120 FIELD TESTS-Plate Loading Tet I carried out to etimate the bearing capacity and ettlement beneath the ingle footing. A loading plate i circular or quare in hape and i manufactured from machined teel plate with a min. thickne of 25mm. The diamater of circular plate range from mm. The load i either of gravity type applied through a platform or reaction type applied by a hydraulic jack. The plate loading tet procedure may be found in ASTM D-1194, ASTM D-1195 and ASTM D

8 PLATE LOAD TEST Mot reliable way to obtain the ultimate bearing capacity at a ite i to perform a load tet. PLATE LOAD TEST Procedure 1) Pile hould be driven firt, to avoid exce vibration & looening of oil in excavation area. 2) Excavate a hole a certain depth that the tet i to be performed. Tet hole depth > 4B 3) A load i placed on the plate (uually teel) and ettlement are recorded from a gauge. Load increment 1/5 bearing capacity of oil or 1/10 etimated failure load. Time of loading 1 hr & hould be ame duration for all increment. Bowle, ) Tet hould continue until ettlement = 25 mm or, until capacity of teting apparatu i reached. PLATE LOAD TEST PLATE LOAD TEST Settlement (cm) If H = 2.5cm failure 50 q ult = 50 t/m 2 Load (t/m 2 ) δ lim Settlement Load Hard/dene oil Looe/oft oil δ lim 1/2 load correponding to 10 mm ettlement Note: Plate load tet reult do not include effect of CONSOLIDATION Load q Coefficient of Subgrade Reaction, k : (ue ecant) : k = q / [unit: kg/cm 3,kN/m 3 ] Settlement Ued to obtain E: when modelling oil a elatic pring (Winkler) 4 d y EI 4 dx = kby 8

9 Coring of Rock When a rock layer i encountered during a drilling operation, rock coring may be neceary. For coring of rock, a core barrel i attached to a drilling rod. A coring bit i attached to the bottom of the core barrel. The coring i advanced by rotary drilling. Water i circulated through the drilling rod during coring and the cutting i wahed out. To evaluate the rock quality encountered, Rock Quality Deignation (RQD) i ued. RQD= ΣLength of recovered piece equal to or larger tha n 101.6mm Theoretica l length of rock cored very poor and i excellent rock quality. Geophyical Teting Advantage relatively cheap compared to borehole and in-itu teting option non-detructive (no hole/excavation are required) Diadvantage reult are often inconcluive or unreliable not yet fully accepted by the indutry. GEOPHYSICAL METHODS Ueful in ground invetigation in reconnaiance tage Supplementary method (not uitable for all oil) Capable of etimating depth to bedrock etimating depth to water table filling in detail between borehole GEOPHYSICAL METHODS 1) Seimic Refraction Method: Seimic wave have different velocitie in different type of oil. Two type of tre wave: P Wave : plane wave 200 m/ in and to 2500 m/ in clay S Wave : hear wave Le cot than other in-itu tet Definitive interpretation of the reult i difficult, o hould be ued for preliminary work 9

10 GEOPHYSICAL METHODS Seimic refraction urvey are ueful in obtaining preliminary information about the thickne of the layering of variou oil and the depth to rock or hard oil at a ite. They are conducted by impacting the urface at a point and oberving the firt arrival of the diturbance (tre wave) at other point. The impact can be created by a hammer blow or by a mall exploive charge. The firt arrival of diturbance wave at variou point can be recorded by geophone. V V rock L T GEOPHYSICAL METHODS P-S wave velocitie: o oil = E ( 1 µ ) o υp = υ = = ( L3 L1 ) ( T T ) 3 G γ g 1 γ g ( 1 2µ )( 1+ µ ) Firt arrival time to detector are determined : υ p 2 2µ = υ 1 2µ For a typical Poion ratio 0.3, the ratio; υ υ p = 1.87 GEOPHYSICAL METHODS GEOPHYSICAL METHODS 2) Electrical Reitivity Method: Difference in electrical reitance of different oil type. Method * Place 4 electrode with equal pacing A. * Apply a direct current to outer electrode I. * Meaure potential drop in inner electrode. The reitivity of oil i determined by: V:Voltage drop Craig, 1992 ρ = 2πLV I The reitivity urvey i particularly ueful in locating gravel depoit within a finegrained oil. 10

11 GEOPHYSICAL METHODS 3) Cro Hole Seimic Survey: Two hole are drilled a ditance, L, apart. A vertical impule i created at the bottom of one of the borehole by an impule. The hear wave generated are recorded by a tranducer at the other borehole. Method Shear wave velocity: Shear modulu : V = L t G = V 2 γ g SOIL EXPLORATION REPORT Scope Decription of tructure Decription of location of ite Geological etting Detailed field exploration Subgrade condition Water table condition Foundation recommendation Concluion and limitation Summary Goal: etimate geometry of oil trata and ground water and etimate pertinent engineering propertie Field Invetigation identify material and layering, retrieve ample and engineering propertie through in-itu teting Laboratory Teting determine engineering propertie from ample 11

INSITU TESTS! Shear Vanes! Shear Vanes! Shear Vane Test! Sensitive Soils! Insitu testing is used for two reasons:!

INSITU TESTS! Shear Vanes! Shear Vanes! Shear Vane Test! Sensitive Soils! Insitu testing is used for two reasons:! In-situ Testing! Insitu Testing! Insitu testing is used for two reasons:! To allow the determination of shear strength or penetration resistance or permeability of soils that would be difficult or impossible

More information

EXPERIMENT 11 CONSOLIDATION TEST

EXPERIMENT 11 CONSOLIDATION TEST 119 EXPERIMENT 11 CONSOLIDATION TEST Purpoe: Thi tet i performed to determine the magnitude and rate of volume decreae that a laterally confined oil pecimen undergoe when ubjected to different vertical

More information

c. Borehole Shear Test (BST): BST is performed according to the instructions published by Handy Geotechnical Instruments, Inc.

c. Borehole Shear Test (BST): BST is performed according to the instructions published by Handy Geotechnical Instruments, Inc. Design Manual Chapter 6 - Geotechnical 6B - Subsurface Exploration Program 6B-2 Testing A. General Information Several testing methods can be used to measure soil engineering properties. The advantages,

More information

INDIRECT METHODS SOUNDING OR PENETRATION TESTS. Dr. K. M. Kouzer, Associate Professor in Civil Engineering, GEC Kozhikode

INDIRECT METHODS SOUNDING OR PENETRATION TESTS. Dr. K. M. Kouzer, Associate Professor in Civil Engineering, GEC Kozhikode INDIRECT METHODS SOUNDING OR PENETRATION TESTS STANDARD PENETRATION TEST (SPT) Reference can be made to IS 2131 1981 for details on SPT. It is a field edtest to estimate e the penetration e resistance

More information

Module 1 : Site Exploration and Geotechnical Investigation. Lecture 4 : In-situ tests [ Section 4.1: Penetrometer Tests ] Objectives

Module 1 : Site Exploration and Geotechnical Investigation. Lecture 4 : In-situ tests [ Section 4.1: Penetrometer Tests ] Objectives Lecture 4 : In-situ tests [ Section 4.1: Penetrometer Tests ] Objectives In this section you will learn the following Penetrometer Tests Standard penetration test Static cone penetration test Dynamic cone

More information

Site Investigation. Some unsung heroes of Civil Engineering. buried right under your feet. 4. Need good knowledge of the soil conditions

Site Investigation. Some unsung heroes of Civil Engineering. buried right under your feet. 4. Need good knowledge of the soil conditions This is an attempt to create a stand alone self learning module on site investigation. Fasten your seat belts. Sit back, relax and enjoy. 1 2 Site Investigation Some unsung heroes of Civil Engineering

More information

σ m using Equation 8.1 given that σ

σ m using Equation 8.1 given that σ 8. Etimate the theoretical fracture trength of a brittle material if it i known that fracture occur by the propagation of an elliptically haped urface crack of length 0.8 mm and having a tip radiu of curvature

More information

SPECIFICATION FOR DYNAMIC CONSOLIDATION / DYNAMIC REPLACEMENT

SPECIFICATION FOR DYNAMIC CONSOLIDATION / DYNAMIC REPLACEMENT SPECIFICATION FOR DYNAMIC CONSOLIDATION / DYNAMIC REPLACEMENT 1.0 SOIL IMPROVEMENT 1.1 General Soil Investigation Information are provided in Part B1 annex as a guide to the Contractor for his consideration

More information

Report 4668-1b 30.10.2010. Measurement report. Sylomer - field test

Report 4668-1b 30.10.2010. Measurement report. Sylomer - field test Report 4668-1b Meaurement report Sylomer - field tet Report 4668-1b 2(16) Contet 1 Introduction... 3 1.1 Cutomer... 3 1.2 The ite and purpoe of the meaurement... 3 2 Meaurement... 6 2.1 Attenuation of

More information

Empirical correlations of overconsolidation ratio, coefficient of earth pressure at rest and undrained strength

Empirical correlations of overconsolidation ratio, coefficient of earth pressure at rest and undrained strength Second Conference of Jnior Reearcher in Civil Engineering 88 Empirical correlation of overconolidation ratio, coefficient of earth prere at ret and ndrained trength Vendel Józa BME Department of Geotechnic,

More information

Geotechnical Measurements and Explorations Prof. Nihar Ranjan Patra Department of Civil Engineering Indian Institute of Technology, Kanpur

Geotechnical Measurements and Explorations Prof. Nihar Ranjan Patra Department of Civil Engineering Indian Institute of Technology, Kanpur Geotechnical Measurements and Explorations Prof. Nihar Ranjan Patra Department of Civil Engineering Indian Institute of Technology, Kanpur Lecture No. # 13 (Refer Slide Time: 00:18) So last class, it was

More information

Eurocode 7 - Geotechnical design - Part 2 Ground investigation and testing

Eurocode 7 - Geotechnical design - Part 2 Ground investigation and testing Brussels, 18-20 February 2008 Dissemination of information workshop 1 Eurocode 7 - Geotechnical design - Part 2 Ground investigation and testing Dr.-Ing. Bernd Schuppener, Federal Waterways Engineering

More information

Anirudhan I.V. Geotechnical Solutions, Chennai

Anirudhan I.V. Geotechnical Solutions, Chennai Anirudhan I.V. Geotechnical Solutions, Chennai Often inadequate In some cases, excess In some cases, disoriented Bad investigation Once in a while good ones Depends on one type of investigation, often

More information

CIVL451. Soil Exploration and Characterization

CIVL451. Soil Exploration and Characterization CIVL451 Soil Exploration and Characterization 1 Definition The process of determining the layers of natural soil deposits that will underlie a proposed structure and their physical properties is generally

More information

How To Design A Foundation

How To Design A Foundation The Islamic university - Gaza Faculty of Engineering Civil Engineering Department CHAPTER (2) SITE INVESTIGATION Instructor : Dr. Jehad Hamad Definition The process of determining the layers of natural

More information

TECHNICAL NOTE: SI 01 SPECIFIC REQUIREMENTS FOR THE ACCREDITATION OF INSPECTION BODIES FOR SITE INVESTIGATION

TECHNICAL NOTE: SI 01 SPECIFIC REQUIREMENTS FOR THE ACCREDITATION OF INSPECTION BODIES FOR SITE INVESTIGATION ACCREDITATION SCHEME FOR INSPECTION BODIES TECHNICAL NOTE: SI 01 SPECIFIC REQUIREMENTS FOR THE ACCREDITATION OF INSPECTION BODIES FOR SITE INVESTIGATION Technical Note SI 01: 3 February 2016 The SAC Accreditation

More information

KWANG SING ENGINEERING PTE LTD

KWANG SING ENGINEERING PTE LTD KWANG SING ENGINEERING PTE LTD 1. INTRODUCTION This report represents the soil investigation works at Aljunied Road / Geylang East Central. The objective of the soil investigation is to obtain soil parameters

More information

Two Dimensional FEM Simulation of Ultrasonic Wave Propagation in Isotropic Solid Media using COMSOL

Two Dimensional FEM Simulation of Ultrasonic Wave Propagation in Isotropic Solid Media using COMSOL Excerpt from the Proceeding of the COMSO Conference 0 India Two Dimenional FEM Simulation of Ultraonic Wave Propagation in Iotropic Solid Media uing COMSO Bikah Ghoe *, Krihnan Balaubramaniam *, C V Krihnamurthy

More information

Figure 2.31. CPT Equipment

Figure 2.31. CPT Equipment Soil tests (1) In-situ test In order to sound the strength of the soils in Las Colinas Mountain, portable cone penetration tests (Japan Geotechnical Society, 1995) were performed at three points C1-C3

More information

Geotechnical Testing Methods II

Geotechnical Testing Methods II Geotechnical Testing Methods II Ajanta Sachan Assistant Professor Civil Engineering IIT Gandhinagar FIELD TESTING 2 1 Field Test (In-situ Test) When it is difficult to obtain undisturbed samples. In case

More information

GUIDELINE FOR HAND HELD SHEAR VANE TEST

GUIDELINE FOR HAND HELD SHEAR VANE TEST GUIDELINE FOR HAND HELD SHEAR VANE TEST NZ GEOTECHNICAL SOCIETY INC August 2001 CONTENTS Page 1.0 Introduction 2 2.0 Background 2 3.0 Recommended Practice 3 4.0 Undrained Shear Strength 3 5.0 Particular

More information

An Automatic Kunzelstab Penetration Test

An Automatic Kunzelstab Penetration Test An Automatic Kunzelstab Penetration Test Yongyuth Sirisriphet 1, Kitidech Santichaianant 2 1 Graduated student: Faculty of Industrial Education in and Technology. King Mongkut's University of Technology

More information

product manual HS-4210 HS-4210_MAN_09.08 Digital Static Cone Penetrometer

product manual HS-4210 HS-4210_MAN_09.08 Digital Static Cone Penetrometer HS-4210_MAN_09.08 product manual HS-4210 Digital Static Cone Penetrometer Introduction This Manual covers the measurement of bearing capacity using the Humboldt Digital Static Cone Penetrometer (DSCP).

More information

Using Combination of SPT, DMT and CPT to Estimate Geotechnical Model for a Special Project in Turkey

Using Combination of SPT, DMT and CPT to Estimate Geotechnical Model for a Special Project in Turkey Using Combination of SPT, DMT and CPT to Estimate Geotechnical Model for a Special Project in Turkey Figen Orhun Onal GE, M.Sc., Site Works Manager, Zemin Etud ve Tasarım A.Ş., Istanbul, [email protected]

More information

Cone Penetration Testing (CPT) Michael Bailey, P.G. U.S. Army Corps of Engineers, Savannah District

Cone Penetration Testing (CPT) Michael Bailey, P.G. U.S. Army Corps of Engineers, Savannah District Cone Penetration Testing (CPT) Michael Bailey, P.G. U.S. Army Corps of Engineers, Savannah District Recommended publications ASTM D 5778-07 Standard Test Method for Electronic Friction Cone and Piezocone

More information

ASSESSMENT OF SHEAR WAVE VELOCITY FROM INDIRECT INSITU TESTS

ASSESSMENT OF SHEAR WAVE VELOCITY FROM INDIRECT INSITU TESTS Proceedings of Indian Geotechnical Conference IGC-2014 December 18-20, 2014, Kakinada, India ASSESSMENT OF SHEAR WAVE VELOCITY FROM INDIRECT INSITU TESTS Kant, L., M. Tech Student, Department of Earthquake

More information

Drained and Undrained Conditions. Undrained and Drained Shear Strength

Drained and Undrained Conditions. Undrained and Drained Shear Strength Drained and Undrained Conditions Undrained and Drained Shear Strength Lecture No. October, 00 Drained condition occurs when there is no change in pore water pressure due to external loading. In a drained

More information

2009 Japan-Russia Energy and Environment Dialogue in Niigata S2-6 TANAKA ERINA

2009 Japan-Russia Energy and Environment Dialogue in Niigata S2-6 TANAKA ERINA Importance of the Site Investigation for Development of Methane Hydrate Hokkaido University Hiroyuki Tanaka Civil Engineer My Background Site Investigation Soil Parameters for Design Very Soft Clay and

More information

1 Mobilisation and demobilisation 1 Deep boring sum 2 Cone penetration tests sum 3 Miscellenous tests sum

1 Mobilisation and demobilisation 1 Deep boring sum 2 Cone penetration tests sum 3 Miscellenous tests sum Malaysian Civil Engineering Standard Method of Measurement (MyCESMM) CLASS D: SITE INVESTIGATION WORK Measurement covered under other classes: Excavation not carried out for the purpose of soil investigation

More information

FLUID MECHANICS. TUTORIAL No.4 FLOW THROUGH POROUS PASSAGES

FLUID MECHANICS. TUTORIAL No.4 FLOW THROUGH POROUS PASSAGES FLUID MECHANICS TUTORIAL No.4 FLOW THROUGH POROUS PASSAGES In thi tutorial you will continue the work on laminar flow and develop Poieuille' equation to the form known a the Carman - Kozeny equation. Thi

More information

GNH7/GG09/GEOL4002 EARTHQUAKE SEISMOLOGY AND EARTHQUAKE HAZARD

GNH7/GG09/GEOL4002 EARTHQUAKE SEISMOLOGY AND EARTHQUAKE HAZARD Earth Material Lecture 13 Earth Material Hooke law of elaticity Force = E Area Hooke law n = E n Extenion Length Robert Hooke (1635-1703) wa a virtuoo cientit contributing to geology, palaeontology, biology

More information

Module5: Site investigation using in situ testing

Module5: Site investigation using in situ testing Module5: Site investigation using in situ testing Topics: Introduction Penetration testing 1. Standard penetration test 2. Cone penetration test Strength and compressibility testing 1. Field vane shear

More information

Standard penetration test (SPT)

Standard penetration test (SPT) Standard penetration test (SPT) Evolution of SPT Test methods and standards Influence of ground conditions on penetration resistance SPT energy measurement and corrections for SPT Use of SPT results Profiling

More information

Improvement in physical properties for ground treated with rapid impact compaction

Improvement in physical properties for ground treated with rapid impact compaction International Journal of the Physical Sciences Vol. 6(22), pp. 5133-5140, 2 October 2011 Available online at http://www.academicjournals.org/ijps ISSN 1992-1950 2011 Academic Journals Full Length Research

More information

Pavements should be well drained both during and upon completion of construction. Water should not be allowed to pond on or near pavement surfaces.

Pavements should be well drained both during and upon completion of construction. Water should not be allowed to pond on or near pavement surfaces. Project No. 208-8719 January, 2009 Ref: 2-8719BR Anthony Hudson - Broadscale Geotechnical Investigation - Proposed Commercial Development - 52 Old Pacific Highway, Pimpama Page 32 iii) Pavements should

More information

Polyethylene (PE) pipes Dimensions

Polyethylene (PE) pipes Dimensions DEUTSCHE NORM Augut 1999 Polyethylene (PE) pipe Dimenion { 8074 ICS 23.040.20 Rohre au Polyethylen (PE) PE 63, PE 80, PE 100, PE HD Maße Superede September 1987 edition. In keeping with current practice

More information

Cone Penetration Testing in Geotechnical Practice. Tom Lunne Peter K. Robertson John J.M. Powell

Cone Penetration Testing in Geotechnical Practice. Tom Lunne Peter K. Robertson John J.M. Powell Cone Penetration Testing in Geotechnical Practice Tom Lunne Peter K. Robertson John J.M. Powell BLACKIE ACADEMIC & PROFESSIONAL An Imprint of Chapman & Hall London Weinheim New York Tokyo Melbourne Madras

More information

BUILT-IN DUAL FREQUENCY ANTENNA WITH AN EMBEDDED CAMERA AND A VERTICAL GROUND PLANE

BUILT-IN DUAL FREQUENCY ANTENNA WITH AN EMBEDDED CAMERA AND A VERTICAL GROUND PLANE Progre In Electromagnetic Reearch Letter, Vol. 3, 51, 08 BUILT-IN DUAL FREQUENCY ANTENNA WITH AN EMBEDDED CAMERA AND A VERTICAL GROUND PLANE S. H. Zainud-Deen Faculty of Electronic Engineering Menoufia

More information

Caltrans Geotechnical Manual

Caltrans Geotechnical Manual Cone Penetration Test The cone penetration test (CPT) is an in-situ sounding that pushes an electronic penetrometer into soil and records multiple measurements continuously with depth. Compared with rotary

More information

CHAPTER 1 INTRODUCTION

CHAPTER 1 INTRODUCTION CHAPTER 1 INTRODUCTION 1.1 Introduction The design and construction of foundations require a good knowledge of the mechanical behaviour of soils and of their spatial variability. Such information can be

More information

GEOTECHNICAL ENGINEERING II. Subject Code : 06CV64 Internal Assessment Marks : 25 PART A UNIT 1

GEOTECHNICAL ENGINEERING II. Subject Code : 06CV64 Internal Assessment Marks : 25 PART A UNIT 1 GEOTECHNICAL ENGINEERING II Subject Code : 06CV64 Internal Assessment Marks : 25 PART A UNIT 1 1. SUBSURFACE EXPLORATION 1.1 Importance, Exploration Program 1.2 Methods of exploration, Boring, Sounding

More information

By D. P. StewarP and M. F. Randolph z

By D. P. StewarP and M. F. Randolph z T-BAR PENETRATION TESTING IN SOFT CLAY By D. P. StewarP and M. F. Randolph z ABSTRACT: A t-bar penetration test for soft clay that can be performed with existing cone penetration test (CPT) equipment is

More information

Linear Momentum and Collisions

Linear Momentum and Collisions Chapter 7 Linear Momentum and Colliion 7.1 The Important Stuff 7.1.1 Linear Momentum The linear momentum of a particle with ma m moving with velocity v i defined a p = mv (7.1) Linear momentum i a vector.

More information

Penetration rate effects on cone resistance measured in a calibration chamber

Penetration rate effects on cone resistance measured in a calibration chamber Penetration rate effects on cone resistance measured in a calibration chamber K. Kim Professional Service Industries, Inc, Houston, TX, USA M. Prezzi & R. Salgado Purdue University, West Lafayette, IN,

More information

Numerical Simulation of CPT Tip Resistance in Layered Soil

Numerical Simulation of CPT Tip Resistance in Layered Soil Numerical Simulation of CPT Tip Resistance in Layered Soil M.M. Ahmadi, Assistant Professor, [email protected] Dept. of Civil Engineering, Sharif University of Technology, Tehran, Iran Abstract The paper

More information

SLOPE STABILITY SLOPE STABILITY. Types of Slope Failure. Types of Slope Failure. Assistant Professor Berrak Teymur

SLOPE STABILITY SLOPE STABILITY. Types of Slope Failure. Types of Slope Failure. Assistant Professor Berrak Teymur SLPE STABILITY Aitant Profeor Berrak Teymur Slope failure SLPE STABILITY An expoe groun urface that tan at an angle with the horizontal i calle an unretraine lope. The lope can be natural or man-mae. Slope

More information

CIV4249 1. SITE INVESTIGATION AND EXPLORATION TABLE OF CONTENTS

CIV4249 1. SITE INVESTIGATION AND EXPLORATION TABLE OF CONTENTS Unit CIV4249: Foundation Engineering 1.1 CIV4249 1. SITE INVESTIGATION AND EXPLORATION TABLE OF CONTENTS 1. GENERAL... 2 1.1. Objectives... 2 1.2. Reasons for investigating Subsurface... 2 1.3. Sources

More information

COMPENDIUM OF INDIAN STANDARDS ON SOIL ENGINEERING PART 2

COMPENDIUM OF INDIAN STANDARDS ON SOIL ENGINEERING PART 2 (PREVIEW) SP 36 (Part 2) : 1988 COMPENDIUM OF INDIAN STANDARDS ON SOIL ENGINEERING PART 2 IS 1893 : 1979 (Reaffirmed 1987) CODE OF PRACTICE FOR SUBSURFACE INVESTIGATION FOR FOUNDATIONS 1.1 This code deals

More information

International Journal of Scientific & Engineering Research, Volume 4, Issue 9, September-2013 409 ISSN 2229-5518

International Journal of Scientific & Engineering Research, Volume 4, Issue 9, September-2013 409 ISSN 2229-5518 International Journal of Scientific & Engineering Research, Volume 4, Issue 9, September-2013 409 Estimation of Undrained Shear Strength of Soil using Cone Penetration Test By Nwobasi, Paul Awo Department

More information

Geotechnic Parameters Analysis Obtained by Pencel Presuremeter Test on Clayey Soils in Resistencia City

Geotechnic Parameters Analysis Obtained by Pencel Presuremeter Test on Clayey Soils in Resistencia City American Journal of Science and Technology 2015; 2(5): 237-242 Published online August 10, 2015 (http://www.aascit.org/journal/ajst) ISSN: 2375-3846 Geotechnic Parameters Analysis Obtained by Pencel Presuremeter

More information

NOTES on the CONE PENETROMETER TEST

NOTES on the CONE PENETROMETER TEST GE 441 Advanced Engineering Geology & Geotechnics Spring 2004 Introduction NOTES on the CONE PENETROMETER TEST The standardized cone-penetrometer test (CPT) involves pushing a 1.41-inch diameter 55 o to

More information

Table of Contents 10.1 GENERAL... 10.1-1

Table of Contents 10.1 GENERAL... 10.1-1 Table of Contents Section Page 10.1 GENERAL... 10.1-1 10.1.1 Overview... 10.1-1 10.1.2 Role of Uncertainty in Property Interpretation... 10.1-1 10.1.3 Role of Drainage in Property Interpretation... 10.1-2

More information

Standard Test Method for Mechanical Cone Penetration Tests of Soil 1

Standard Test Method for Mechanical Cone Penetration Tests of Soil 1 Designation: D 3441 98 AMERICAN SOCIETY FOR TESTING AND MATERIALS 100 Barr Harbor Dr., West Conshohocken, PA 19428 Reprinted from the Annual Book of ASTM Standards. Copyright ASTM Standard Test Method

More information

TECHNICAL REPORT ON SCALA DYNAMIC CONE PENETROMETER IRREGULARITY

TECHNICAL REPORT ON SCALA DYNAMIC CONE PENETROMETER IRREGULARITY TECHNICAL REPORT ON SCALA DYNAMIC CONE PENETROMETER IRREGULARITY CETANZ Technical Report TR 1 Author(s) SJ Anderson, Geotechnics Ltd Report Date First Issue May 2010 Report Revision Date September 2011

More information

CHAPTER 9 SOIL EXPLORATION 9.1 INTRODUCTION

CHAPTER 9 SOIL EXPLORATION 9.1 INTRODUCTION CHAPTER 9 SOIL EXPLORATION 9.1 INTRODUCTION The stability of the foundation of a building, a bridge, an embankment or any other structure built on soil depends on the strength and compressibility characteristics

More information

ALLOWABLE LOADS ON A SINGLE PILE

ALLOWABLE LOADS ON A SINGLE PILE C H A P T E R 5 ALLOWABLE LOADS ON A SINGLE PILE Section I. BASICS 5-1. Considerations. For safe, economical pile foundations in military construction, it is necessary to determine the allowable load capacity

More information

Use and Application of Piezocone Penetration Testing in Presumpscot Formation

Use and Application of Piezocone Penetration Testing in Presumpscot Formation Use and Application of Piezocone Penetration Testing in Presumpscot Formation Craig W. Coolidge, P.E. Summit Geoengineering Services, Rockland, Maine ABSTRACT: This paper examines the advantages and limitations

More information

Geotechnical Investigation Test Report

Geotechnical Investigation Test Report Geotechnical Investigation Test Report Report No. htsc/rcd/ 3457 Dated: - 20/03/2010 Asphalt Standard Penetration Test as per IS 2131 ------------- IS 6403 Soil Job Card No - 1649 Cement Client/Department

More information

CONSTANT HEAD AND FALLING HEAD PERMEABILITY TEST

CONSTANT HEAD AND FALLING HEAD PERMEABILITY TEST CONSTANT HEAD AND FALLING HEAD PERMEABILITY TEST 1 Permeability is a measure of the ease in which water can flow through a soil volume. It is one of the most important geotechnical parameters. However,

More information

1.0 INTRODUCTION 1 2.0 SCOPE OF WORK 2 3.0 EXECUTION OF FIELD WORK 2 4.0 LABORATORY TESTS 8 5.0 FINDINGS OF THE GEOTECHNICAL INVESTIGATION 9

1.0 INTRODUCTION 1 2.0 SCOPE OF WORK 2 3.0 EXECUTION OF FIELD WORK 2 4.0 LABORATORY TESTS 8 5.0 FINDINGS OF THE GEOTECHNICAL INVESTIGATION 9 REPORT ON GEOTECHNICAL INVESTIGATION FOR LPG MOUNDED STORAGE AT VISAKHA REFINERY, MALKAPURAM, VISAKHAPATNAM (A.P) FOR HINDUSTAN PETROLEUM CORPORATION LIMITED CONTENTS SR.NO. DESCRIPTION PAGE NO. 1.0 INTRODUCTION

More information

CPTic_CSM8. A spreadsheet tool for identifying soil types and layering from CPTU data using the I c method. USER S MANUAL. J. A.

CPTic_CSM8. A spreadsheet tool for identifying soil types and layering from CPTU data using the I c method. USER S MANUAL. J. A. CPTic_CSM8 A spreadsheet tool for identifying soil types and layering from CPTU data using the I c method. USER S MANUAL J. A. Knappett (2012) This user s manual and its associated spreadsheet ( CPTic_CSM8.xls

More information

ODOT/OSU collaboration on the development of CPT Capabilities for use in Ohio Transportation Projects

ODOT/OSU collaboration on the development of CPT Capabilities for use in Ohio Transportation Projects CPT Cone Penetration Testing ODOT/OSU collaboration on the development of CPT Capabilities for use in Ohio Transportation Projects Presented by: Jason Ross, Staff Engineer, BBC&M Engineering, Inc. Kirk

More information

Module 1 : Site Exploration and Geotechnical Investigation. Lecture 5 : Geophysical Exploration [ Section 5.1 : Methods of Geophysical Exploration ]

Module 1 : Site Exploration and Geotechnical Investigation. Lecture 5 : Geophysical Exploration [ Section 5.1 : Methods of Geophysical Exploration ] Objectives In this section you will learn the following General Overview Different methods of geophysical explorations Electrical resistivity method Seismic refraction method 5 Geophysical exploration

More information

FINAL REPORT ON SOIL INVESTIGATION

FINAL REPORT ON SOIL INVESTIGATION FINAL REPORT ON SOIL INVESTIGATION FOR PROPOSED CONSTRUCTION AT SS-6B AREA AT HPCL VISAKH REFINERY VISAKHAPATNAM ANDHRA PRADESH J.J. ASSOCIATES(VISAKHAPATNAM) AETP(P) LIMITED #11-6-3, RockDale Layout,

More information

GEOTECHNICAL DESIGN MANUAL

GEOTECHNICAL DESIGN MANUAL GEOTECHNICAL DESIGN MANUAL CHAPTER 4 GEOTECHNICAL FIELD INVESTIGATION NYSDOT Geotechnical Page 4-1 December 10, 2013 (Intentionally left blank) NYSDOT Geotechnical Page 4-2 December 10, 2013 Table of Contents

More information

Analysis of Mesostructure Unit Cells Comprised of Octet-truss Structures

Analysis of Mesostructure Unit Cells Comprised of Octet-truss Structures Analyi of Meotructure Unit Cell Compried of Octet-tru Structure Scott R. Johnton *, Marque Reed *, Hongqing V. Wang, and David W. Roen * * The George W. Woodruff School of Mechanical Engineering, Georgia

More information

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 3, No 3, 2013

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 3, No 3, 2013 INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 3, No 3, 2013 Copyright by the authors - Licensee IPA- Under Creative Commons license 3.0 Research article ISSN 0976 4399 Reliability of

More information

APPENDIX A PRESSUREMETER TEST INTERPRETATION

APPENDIX A PRESSUREMETER TEST INTERPRETATION APPENDIX A PRESSUREMETER TEST INTERPRETATION PRESSUREMETER TEST INTERPRETATION Description of test The pressuremeter test, discussed in great detail by Martin (1977), Baguelin et al. (1978), Barksdale

More information

v = x t = x 2 x 1 t 2 t 1 The average speed of the particle is absolute value of the average velocity and is given Distance travelled t

v = x t = x 2 x 1 t 2 t 1 The average speed of the particle is absolute value of the average velocity and is given Distance travelled t Chapter 2 Motion in One Dimenion 2.1 The Important Stuff 2.1.1 Poition, Time and Diplacement We begin our tudy of motion by conidering object which are very mall in comparion to the ize of their movement

More information

CPTWD (Cone Penetration Test While Drilling) a new method for deep geotechnical surveys

CPTWD (Cone Penetration Test While Drilling) a new method for deep geotechnical surveys CPTWD (Cone Penetration Test While Drilling) a new method for deep geotechnical surveys Authors : Massimo Sacchetto-Engineer-: S P G drilling company -Adria (Ro) Italy Kjell Elmgren Engineer ENVI Environmental

More information

Cone Penetration Test (CPT)

Cone Penetration Test (CPT) Cone Penetration Test (CPT) The cone penetration test, or CPT in short, is a soil testing method which will provide a great deal of high quality information. In the Cone Penetration Test (CPT), a cone

More information

Design Capacities for Structural Plywood

Design Capacities for Structural Plywood Deign Capacitie for Structural Plyood Alloale Stre Deign (ASD) The deign value in thi document correpond ith thoe pulihed in the 005 edition of the AF&PA American Wood Council Alloale Stre Deign (ASD)/RFD

More information

Heat transfer to or from a fluid flowing through a tube

Heat transfer to or from a fluid flowing through a tube Heat tranfer to or from a fluid flowing through a tube R. Shankar Subramanian A common ituation encountered by the chemical engineer i heat tranfer to fluid flowing through a tube. Thi can occur in heat

More information

DYNAMIC CONE PENETRATION TEST INSTRUCTIONAL MANUAL GEOTECHANICAL

DYNAMIC CONE PENETRATION TEST INSTRUCTIONAL MANUAL GEOTECHANICAL DYNAMIC CONE PENETRATION TEST INSTRUCTIONAL MANUAL GEOTECHANICAL J. P. Scientific Instruments 7, Civil Lines, Roorkee-247667 DYNAMIC CONE PENETRATION TEST CONTENTS: PAGE NO. 1.0 INTRODUCTION 03 2.0 PROBLEM

More information

Ingeniería y Georiesgos Ingeniería Geotécnica Car 19 a Nº 84-14 of 204 ; TEL : 6916043 E-mail: [email protected]

Ingeniería y Georiesgos Ingeniería Geotécnica Car 19 a Nº 84-14 of 204 ; TEL : 6916043 E-mail: igr@ingeoriesgos.com The plot below presents the cross correlation coeficient between the raw qc and fs values (as measured on the field). X axes presents the lag distance (one lag is the distance between two sucessive CPT

More information

Acceleration-Displacement Crash Pulse Optimisation A New Methodology to Optimise Vehicle Response for Multiple Impact Speeds

Acceleration-Displacement Crash Pulse Optimisation A New Methodology to Optimise Vehicle Response for Multiple Impact Speeds Acceleration-Diplacement Crah Pule Optimiation A New Methodology to Optimie Vehicle Repone for Multiple Impact Speed D. Gildfind 1 and D. Ree 2 1 RMIT Univerity, Department of Aeropace Engineering 2 Holden

More information

QUESTION TO AUDIENCE

QUESTION TO AUDIENCE Site investigation some aspects of EN1997 Part 2 David Norbury David Norbury Limited BGA Symposium Eurocode 7 Today and Tomorrow, Cambridge, England, March 2011 QUESTION TO AUDIENCE How many of you have

More information

Soil Classification Through Penetration Tests

Soil Classification Through Penetration Tests Pak. J. Engg. & Appl. Sci. Vol. 9, Jul., 2011 (p. 76-86) Soil Classification Through Penetration Tests A. H. Khan, A. Akbar, K. Farooq, N. M. Khan, M. Aziz and H. Mujtaba Department of Civil Engineering,

More information

INTRODUCTION TO SOIL MODULI. Jean-Louis BRIAUD 1

INTRODUCTION TO SOIL MODULI. Jean-Louis BRIAUD 1 INTRODUCTION TO SOIL MODULI By Jean-Louis BRIAUD 1 The modulus of a soil is one of the most difficult soil parameters to estimate because it depends on so many factors. Therefore when one says for example:

More information

PREDICTING THE HYDRAULIC CONDUCTIVITY OF MAKASSAR MARINE CLAY USING FIELD PENETRATION TEST (CPTU) RESULTS

PREDICTING THE HYDRAULIC CONDUCTIVITY OF MAKASSAR MARINE CLAY USING FIELD PENETRATION TEST (CPTU) RESULTS Proceedings of the Sixth International Conference on Asian and Pacific Coasts (APAC 2011) December 14 16, 2011, Hong Kong, China PREDICTING THE HYDRAULIC CONDUCTIVITY OF MAKASSAR MARINE CLAY USING FIELD

More information

The physical survey is that part of site investigation which aims to determine the physical properties of the ground. These are required:

The physical survey is that part of site investigation which aims to determine the physical properties of the ground. These are required: Chapter 9 In situ testing INTRODUCTION The physical survey is that part of site investigation which aims to determine the physical properties of the ground. These are required: 1. to classify the soil

More information

STP883-EB/Nov. 1985. Subject Index

STP883-EB/Nov. 1985. Subject Index STP883-EB/Nov. 1985 Subject Index A Aas in-situ tests, 209-210 Analytical model technique, 432, 438 Andersen's procedure, 342, 345,349-351 Arabian Gulf soils, 413 ASCE conference, 41 ASTM Standards D 422:385

More information

GUIDE TO CONE PENETRATION TESTING

GUIDE TO CONE PENETRATION TESTING GUIDE TO CONE PENETRATION TESTING www.greggdrilling.com Engineering Units Multiples Micro (μ) = 10-6 Milli (m) = 10-3 Kilo (k) = 10 +3 Mega (M) = 10 +6 Imperial Units SI Units Length feet (ft) meter (m)

More information

CPTs EXECUTED IN DIFFICULT CONDITIONS USING CPTWD (CONE PENETRATION TEST WHILE DRILLING) AND ITS FUTURE DEVELOPMENTS

CPTs EXECUTED IN DIFFICULT CONDITIONS USING CPTWD (CONE PENETRATION TEST WHILE DRILLING) AND ITS FUTURE DEVELOPMENTS CPTs EXECUTED IN DIFFICULT CONDITIONS USING CPTWD (CONE PENETRATION TEST WHILE DRILLING) AND ITS FUTURE DEVELOPMENTS M.Sacchetto A.Trevisan S.P.G. s.r.l. via dell artigianato 24 45011 Adria (Ro) Italy

More information

Chapter 5 FIELD AND LABORATORY TESTING PROCEDURES

Chapter 5 FIELD AND LABORATORY TESTING PROCEDURES Chapter 5 FIELD AND LABORATORY TESTING PROCEDURES Final SCDOT GEOTECHNICAL DESIGN MANUAL August 2008 Table of Contents Section Page 5.1 Introduction...5-1 5.2 Sampling Procedure...5-1 5.2.1 Soil Sampling...5-1

More information

Applicability of Standard Penetration Test in Bangladesh and Graphical Representation of SPT-N Value

Applicability of Standard Penetration Test in Bangladesh and Graphical Representation of SPT-N Value International Journal of Science and Engineering Investigations vol. 4, issue 41, June 2015 ISSN: 2251-8843 Applicability of Standard Penetration Test in Bangladesh and Graphical Representation of SPT-N

More information

GUIDE TO CONE PENETRATION TESTING

GUIDE TO CONE PENETRATION TESTING GUIDE TO CONE PENETRATION TESTING www.greggdrilling.com Engineering Units Multiples Micro (μ) = 10-6 Milli (m) = 10-3 Kilo (k) = 10 +3 Mega (M) = 10 +6 Imperial Units SI Units Length feet (ft) meter (m)

More information

Geotechnical Standards Eurocodes. An update

Geotechnical Standards Eurocodes. An update Geotechnical Standards Eurocodes. An update Professor Ltd Sussex University EUROCOE 7 (EN 1997) Part 1 published. 2004 National Annex published 2007 Part 2 published Mar 2007 National Annex published 2010

More information

King Saud University College of Engineering Civil Engineering Department DEFORMATION OF PARTIALLY SATURATED SAND. Sultan Musaed Al-Ghamdi

King Saud University College of Engineering Civil Engineering Department DEFORMATION OF PARTIALLY SATURATED SAND. Sultan Musaed Al-Ghamdi King Saud University College of Engineering Civil Engineering Department DEFORMATION OF PARTIALLY SATURATED SAND By Sultan Musaed Al-Ghamdi Submitted in Partial Fulfillment of The Required For the Degree

More information

Comparison of Continuous Dynamic Probing with the Standard Penetration Test for Highly Weathered Limestone of Eastern Sudan

Comparison of Continuous Dynamic Probing with the Standard Penetration Test for Highly Weathered Limestone of Eastern Sudan Comparison of Continuous Dynamic Probing with the Standard Penetration Test for Highly Weathered Limestone of Eastern Sudan Prof. Dr. Khairul Anuar Kassim Deputy Dean, Research and Graduate Studies, Faculty

More information

Which in-situ test should I use? A designer s guide

Which in-situ test should I use? A designer s guide Roger A. Failmezger, P.E., F. ASCE, In-Situ Soil Testing, L.C., Lancaster, Virginia, email: [email protected], and Paul J. Bullock, Ph.D., P.E., M.ASCE, GRL Engineers, Inc., Gainesville, Florida,

More information

The Challenge of Sustainability in the Geo-Environment Proceedings of the Geo-Congress 2008 ASCE New Orleans LA

The Challenge of Sustainability in the Geo-Environment Proceedings of the Geo-Congress 2008 ASCE New Orleans LA The Challenge of Sustainability in the Geo-Environment Proceedings of the Geo-Congress 2008 ASCE New Orleans LA Strength and Permeability of a Deep Soil Bentonite Slurry Wall Christopher R. Ryan P.E. M

More information

VOLUME III GEOLOGY, HYDROGEOLOGY & GEOTECHNICAL REPORT CAPITAL REGION RESOURCE RECOVERY CENTRE

VOLUME III GEOLOGY, HYDROGEOLOGY & GEOTECHNICAL REPORT CAPITAL REGION RESOURCE RECOVERY CENTRE 2.0 SITE INVESTIGATION METHODOLOGY The following section summarizes the Site investigation methodology applied during the subsurface investigation and hydrogeological assessment completed at the CRRRC

More information

In Situ Subsurface Characterization

In Situ Subsurface Characterization 27 In Situ Subsurface Characterization J. David Frost Georgia Institute of Technology Susan E. Burns Georgia Institute of Technology 27.1 Introduction 27.2 Subsurface Characterization Methodology 27.3

More information

Soil behaviour type from the CPT: an update

Soil behaviour type from the CPT: an update Soil behaviour type from the CPT: an update P.K. Robertson Gregg Drilling & Testing Inc., Signal Hill, California, USA ABSTRACT: An initial application of CPT results is to evaluate soil type and soil

More information

Chapter 3 Torque Sensor

Chapter 3 Torque Sensor CHAPTER 3: TORQUE SESOR 13 Chapter 3 Torque Senor Thi chapter characterize the iue urrounding the development of the torque enor, pecifically addreing meaurement method, tranducer technology and converter

More information

NEW DEVELOPMENTS AND IMPORTANT CONSIDERATIONS FOR STANDARD PENETRATION TESTING FOR LIQUEFACTION EVALUATIONS. Jeffrey A Farrar M.S.

NEW DEVELOPMENTS AND IMPORTANT CONSIDERATIONS FOR STANDARD PENETRATION TESTING FOR LIQUEFACTION EVALUATIONS. Jeffrey A Farrar M.S. NEW DEVELOPMENTS AND IMPORTANT CONSIDERATIONS FOR STANDARD PENETRATION TESTING FOR LIQUEFACTION EVALUATIONS Jeffrey A Farrar M.S., P E 1 ABSTRACT Standard Penetration Tests (SPT) are often used for evaluating

More information

System. Stability. Security. Integrity. 150 Helical Anchor

System. Stability. Security. Integrity. 150 Helical Anchor Model 150 HELICAL ANCHOR System PN #MBHAT Stability. Security. Integrity. 150 Helical Anchor System About Foundation Supportworks is a network of the most experienced and knowledgeable foundation repair

More information