1 C H A P T E R 5 ALLOWABLE LOADS ON A SINGLE PILE Section I. BASICS 5-1. Considerations. For safe, economical pile foundations in military construction, it is necessary to determine the allowable load capacity of a single pile under various load conditions Principles. A structure is designed on pile supports if the soil is inadequate for other types of foundations. The basic principles for pile foundations are that they must be safe against breaking (bearing capacity and shear failure) and buckling and that they must not settle excessively or exceed the soil s bearing capacity. There can be other factors, such as the need to protect a bridge pile from scour Requirements. The requirements for the preliminary design of a pile foundation follow. a. Studying soil. Obtain a soil profile resulting from subsurface explorations. This analysis will determine whether the piles will be friction (sand or clay), end bearing (stratum of firm earth), or a combination of both. Local experience can be a useful guide, and sufficient laboratory test data to estimate strength and compressibility of major strata are required. b. Determining pile length. The most accurate method for determining the length of friction piles is to drive and load test piles. Since the time factor in a theater of operations rarely permits driving and load testing of fiction piles, lengths may be calculated from analysis of the soil profile. Uniformity of soil conditions will determine the number of test piles driven at selected locations to verify the computed lengths. On small projects and for hasty construction, dynamic formulas may be used to assess the allowable pile load. If soil conditions are nonuniform and estimating pile lengths accurately is difficult, a pile with an easily adjustable length (timber or steel) should be used. The driving resistance in blows per inch should be used to establish allowable loads by comparing results of nearby piles in similar soil conditions. For deliberate construction, where little experience is available, load tests on selected piles should be performed and interpreted. A minimum of three driving tests (and more if subsurface conditions are erratic) should be 5-1
2 performed. Record driving resistance of test piles and all piles installed. Compare the resistances of the test piles to insure against localized weak subsurface conditions. Section II. STRUCTURAL DESIGNS 5-4. Structural capacity. a. Allowable pile stresses. Overstress in timber piles under design loads should not exceed the values given in table 2-2. The allowable stress in steel piles should not exceed 12,000 psi. Estimate possible reductions in steel cross section for corrosive location or provide protection from corrosion. The allowable stress in precast or cast-inplace piles should not exceed 33 percent of the concrete cylinder strength at 28 days. b. Driving stresses. Do not damage the piles by overdriving. Final driving resistances for various pile types should be limited to the values indicated in chapter 4. c. Buckling failures. There is no danger of buckling a fully-embedded, axially-loaded, point-bearing pile of conventional dimensions because of inadequate lateral support, provided it is surrounded by even the softest soils. The ultimate load for buckling of slender steel piles in soft clay is discussed later in this chapter. Buckling may be a problem when piles project appreciably above ground surfaces. In such cases, the unsupported lengths of the pile should be used in columnstress formulas to determine the safe load capacity. The unsupported length, 1, is computed assuming the pile is laterally supported at 10 feet below ground surface in soft soils and 5 feet in sands and firm soils. This laterally supported point is commonly referred to as a fixed point (see figure 5-l). d. Lateral loads. Lateral forces on embedded piles may produce high bending stresses and deflections. The behavior of short, rigid piles under lateral loads is discussed later in this chapter. The behavior of relatively flexible piles extending appreciably above ground surfaces and subjected to lateral loads is beyond the scope of this manual Column-stress formulas. a. Slenderness ratio. (1) Timber piles. The slenderness ratio (l u /d) is the ratio of the effective unsupported length (1 u ) to the average pile diameter (d). The average pile diameter is measured at a point one-third the distance from the butt of the pile. For the effective unsupported length of a single row of piles unbraced in the longitudinal direction, l u is 0.7 of the distance from the fixed point to the top of the piles, as shown in figure 5-1. For a single row of piles adequately braced in the longitudinal direction, l u is one-half the distance from the fixed point to the lowest bracing. For piles arranged in two or more rows and adequately braced between rows, the unbraced length is one. half the fixed point to the lowest bracing as shown in figure 5-1. If the ratio (l u /d) is less than 11, then a buckling capacity need not be determined. If the ratio exceeds a value of 11, the buckling capacity must be determined. To avoid use of extremely slender piles, the value of l u /d should not exceed 40. When the slenderness ratio is less than 11, the allowable load is based on table 2-2. When the slenderness ratio exceeds a value of 11, the allowable concentric axial load is computed as the lesser of the following. 5-2
3 (2) Steel piles. The slenderness ratio of steel piles is the ratio of the unsupported length (1.) as described to the least radius of gyration(r). Tables and formulas for the radius of gyration are given in TM The buckling capacity of steel piles must always be determined regardless of the numerical value of l u /r. For the most economical design, the value of l u /r should not exceed 120. For steel piles the allowable buckling load is calculated as follows. 5-3
4 Section III. DYNAMIC FORMULAS 5-6. Concept. piles driven with a double-acting air or steam hammer or closed-ended diesel hammer. Dynamic pile formulas are based on the theory that the allowable load on a pile is closely related to the resistance encountered during driving. The concept assumes that the soil resistance remains constant during and after driving operations. This may be true for coarse-grained soils, but may be in error for fine-grained soils because of the reduction in strength due to remolding caused by pile driving. The formula of principal use to the military engineer is the Engineering News formula Engineering News formula The allowable load on a pile may be estimated by one of the following versions of the Engineering News formula Pile set. To determine the pile set, attach a piece of heavy paper to the pile at a convenient height (figure 5-2). Place a straightedge close to the paper supported by stakes spaced two feet on each side of the pile. Draw a pencil steadily 5-4
5 across the straightedge while striking the. pile with a series of blows. This trace will show the set of net penetration of the pile for a given blow of the hammer. For example, assume that a timber pile is driven by an 1,800-pound drop hammer with a height of fall equal to 6 feet. During the last 6 inches of driving, the average pile set is measured and found to be 0.25 inch. Using the Engineering News formula applicable to drop hammers, the allowable load is computed as follows. Q all = 2 x 1,800x6 = 17,280 pounds or 8.6 tons Application. The Engineering News formula provides conservative values in some cases and unsafe values in other cases. Reasonably reliable results are obtained for piles in coarse-grained soils. Generally, when time is available and the cost is justified, pile load tests should be used in conjunction with the dynamic formulas for estimating allowable pile loads. Using only the dynamic formula should be restricted to hasty construction and to projects where the cost of load testing would be too high in relation to the total cost of piles. 5-5
6 Dynamic formulas are useful in correlating penetration resistance obtained from local experience and in relating the results of load tests to the behavior of piles actually driven. a. Saturated fine sands. In saturated fine sands, the formula usually indicates the allowable load as being less than that which may develop after driving. If time is available, a friction pile that has not developed its required load should be rested for at least 24 hours. The capacity may then be checked with at least 10 blows from a drop hammer or 30 blows with a steam, pneumatic, or diesel hammer. If the average penetration is less than that required by the formula to give the needed bearing capacity, piles do not require splicing or deeper driving. If the required capacity is not developed after the rest period, the piles must be spliced or additional piles driven, if the design of the foundation permits. b. Jetting. The formulas do not apply to piles driven by the aid of jetting unless the pile is permitted to rest after jetting and then driven to final position without jetting. Data from the final driving may be used in the dynamic formula after resting the pile. The formulas do not apply to end-bearing piles driven to rock or other firm strata. Section IV. STATIC FORMULAS Driven piles. Static pile formulas are based on the shear strength of the foundation soils. These formulas compute the ultimate bearing capacity and allowable load. Static pile formulas apply to piles in clay (figure 5-3) and to piles completely or partially embedded in cohesionless soil (figure 5-4). The shear strength must be determined from laboratory tests on undisturbed samples or estimated from correlations with the standard pene tration test. The latter method is generally more reliable for cohesionless soils. Typical values of the undrained shear strength of cohesive soils are shown in table 5-1. The ultimate capacity of piles in cohesionless soils is influenced by the position of the groundwater table. Depending on the certainty with which subsoil conditions are known, the ultimate bearing capacity should be divided by a factor of safety from 1.5 to 2.0 to obtain the allowable load. For a given allowable load, the static formulas (figures 5-3, 5-4) also determine the required length of piles, the pullout capacities of piles, and the ultimate load buckle of slender steel piles in soft clay Drilled piles. The allowable load on drilled piles is based on soils shear strength data and from formulas similar to those for driven piles. In clays, the average undisturbed shear strength over the depth of the pile should be multiplied by an empirical earth pressure coefficient, K c, varying from 0.35 to 0.75 to account for softening. If the hole is allowed to remain open for more than a day or two or if a slurry is used during construction, the lower values should be used. In sands, the coefficient of earth pressure, Kc, should be taken as 1.0. The allowable end-bearing capacity, Q d,, can also be computed using the standard penetration test results in terms of N blows per foot. 5-6
7 5-7
8 5-8
9 Section V. PILE LOAD TESTS Equipment. Load tests determine the allowable load, the settlement under working load, or the soundness of a pile. Load tests may be conducted in compression or tension. Lateral load tests are seldom justified. The following considerations must be made. The test piles should be of the same type and driven by the same equipment as for construction. Test loading should not be initiated less than 24 hours after driving piles in cohesionless soils and not less than 7 days in cohesive soils. The load is usually applied by a hydraulic jack reacting against dead weights or against a yoke fastened to a pair of anchor piles (figure 5-5). Anchor piles should beat least 5 test pile diameters from the test pile. The test load should be twice the proposed design load as estimated from the dynamic formula, static formula, or other means. 5-9
10 Readings of settlement and rebounds should be referred to a deep benchmark and recorded to feet Procedures. The loading procedure may be carried out either by the continuous load method or the constant rate of penetration (CRP) method. a. Continuous load. The load is applied in seven increments, equal to ½, ¾, 1, 1¼, 1 ½, 1¾, and 2 times the allowable load assumed for design. The load is maintained constant at each increment until there is no settlement in a 2 hour period. The total test load should remain in place until settlement does not exceed feet in 48 hours. The total load should be removed in decrements not exceeding one fourth of the total test load with intervals of not less than one hour. The rebound should be recorded after each decrement is removed. A curve may then be prepared showing the relationship between the load and deflection (figure 5-6). This procedure is most reliable where it is necessary to estimate the settlement of piles under the design load. The allowable load is taken as one half that which caused a net settlement of not more than ½ inch or gross 5-10
11 settlement of 1 inch, whichever is less. The continuous load method is rarely justified in military construction because of the excessive time requirements. b. Constant rate of penetration. The pile is jacked into the ground at a constant rate, and a continuous record of the load and deformation is taken. The test proceeds rapidly and requires the services of several observers. Results of the test are not too sensitive to the rate of penetration. The load is increased until the pile fails by plunging or the capacity of the equipment is reached. Results of the test are plotted (figure 5-7). The allowable load is considered to be 50 percent of the ultimate bearing capacity defined by the intersection of lines drawn tangent to the two basic portions of the load settlement curve. The constant penetration rate method, a very rapid test, is particularly suited for military construction Bearing stratum resistance. Where piles are driven through compressible soil strata into a bearing stratum of sand or other firm material, the allowable pile load is based on the carrying capacity of the bearing stratum without depending on the short-term frictional resistance of the compressible soils (figure 5-4). With pile load tests, it is generally not possible to distinguish between the shortterm carrying capacity of the compressible soil and the long-term carrying capacity of the bearing stratum. The capacity of the bearing stratum can be obtained by testing the pile inside the hollow casing or by making a load test on two piles driven about 5 feet apart. One pile is driven to refusal in the bearing stratum while the other is driven to within 3 feet of the bearing stratum. The difference in the ultimate loads for the two piles is equal to the carrying capacity of the bearing stratum. 5-11
12 5-15. Limitations of pile load tests. deep enough to sustain vertical loads will develop enough lateral resistance to prevent Pile load tests do not take into account the the structure founded on a number of piles effects of group action on bearing capacity from overturning. An exception to this could unless a group of piles is loaded. The be a bridge foundation in an area subject to settlement of a pile group is not generally scour during periods of high water. When related to the settlement recorded during a piles are subjected to lateral loads in excess of load test on a single pile. Settlement must be 1,000 pounds per pile, it is usually more estimated as discussed in chapter 6 from economical and desirable to provide batter consideration of soil compressibility within piles. Lateral loads apply to both rigid and the zone of the influence (figure 5-6). flexible piles (figure 5-9) Lateral loads resistance. a. Lateral loads. Vertical piles supporting structures are subjected to lateral forces. For example, a pile bent supporting a highway bridge may be subjected to the forces of wind, current, ice, and the impact of floating objects. Similar forces may act on waterfront structures, such as wharves and piers. Properly designed bracing, supplemented by batter piles and fenders, will usually provide the structure with sufficient stability to resist lateral loads. The piles must be driven deep enough to prevent the structure from overturning. Normally, vertical piles driven 5-12 b. Flexible and rigid piles. It is difficult to estimate the resistance provided by a single vertical pile (or group of piles) to lateral forces. The best method is to conduct field loading tests. If time and facilities for this are lacking, the embedment or lateral capacity may be estimated by the use of charts (figures 5-10, 5-11) that apply to fixed-end and freehead short, rigid piles. The effect of group action is ignored in these charts. For the fixed-head pile, failure occurs when the pile moves as a unit through the soil. For the freehead pile, failure occurs when the pile rotates as a unit through the soil around a point located below the ground surface. Theoretical
13 analysis has been developed and is available for laterally loaded piles in which the flexibility of the pile is considered. (1) Rigid piles in clay. Figure 5-10 shows the relationship between the ultimate lateral resistance and length of embedment for fixed-end and free-head piles in clay soils in terms of the undrained shear strength (table 5-l). As the shear strength of the soil near ground surface depends on seasonal variations in water content, it is good practice to reduce laboratory values by one-third to one-fourth. A safety factor from 1.5 to 2.0 should be applied to the design lateral load to compute the ultimate lateral resistance. Continuous lateral loads should be resisted by batter piles. (2) Rigid piles in sand. Figure 5-11 shows the relationship between the ultimate lateral resistance and length of embedment for fixed-end and free-head piles in sands in terms of coefficient of passive earth pressure, K p, assumed equal to 3.0 regardless of the density of the sand. Safety factors from 1.5 to 2.0 should be applied to the design lateral load to compute the ultimate lateral resistance. 5-13
14 5-14
15 5-15
16 5-16
PILE FOUNDATIONS FM 5-134
C H A P T E R 6 PILE FOUNDATIONS Section I. GROUP BEHAVIOR 6-1. Group action. Piles are most effective when combined in groups or clusters. Combining piles in a group complicates analysis since the characteristics
GLOSSARY OF TERMINOLOGY
GLOSSARY OF TERMINOLOGY AUTHORIZED PILE LENGTHS - (a.k.a. Authorized Pile Lengths letter) Official letter stating Engineer's recommended length of concrete piles to be cast for construction of foundation.
Step 11 Static Load Testing
Step 11 Static Load Testing Test loading is the most definitive method of determining load capacity of a pile. Testing a pile to failure provides valuable information to the design engineer and is recommended
1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona
for Earthen Material and Straw Bale Structures SECTION 70 - GENERAL "APPENDIX CHAPTER 7 - EARTHEN MATERIAL STRUCTURES 70. Purpose. The purpose of this chapter is to establish minimum standards of safety
INDIRECT METHODS SOUNDING OR PENETRATION TESTS. Dr. K. M. Kouzer, Associate Professor in Civil Engineering, GEC Kozhikode
INDIRECT METHODS SOUNDING OR PENETRATION TESTS STANDARD PENETRATION TEST (SPT) Reference can be made to IS 2131 1981 for details on SPT. It is a field edtest to estimate e the penetration e resistance
DISTRIBUTION OF LOADSON PILE GROUPS
C H A P T E R 7 DISTRIBUTION OF LOADSON PILE GROUPS Section I. DESIGN LOADS 7-1. Basic design. The load carried by an individual pile or group of piles in a foundation depends upon the structure concerned
PDCA Driven-Pile Terms and Definitions
PDCA Driven-Pile Terms and Definitions This document is available for free download at piledrivers.org. Preferred terms are descriptively defined. Potentially synonymous (but not preferred) terms are identified
DESIGNING STRUCTURES IN EXPANSIVE CLAY
DESIGNING STRUCTURES IN EXPANSIVE CLAY A GUIDE FOR A RCHITECTS AND E NGINEERS Table of Contents 1. Introduction Page 1 2. Common Foundation Systems Page 2 3. Drilled Piers Page 3 a. Skin Friction Piers
REINFORCED CONCRETE. Reinforced Concrete Design. A Fundamental Approach - Fifth Edition. Walls are generally used to provide lateral support for:
HANDOUT REINFORCED CONCRETE Reinforced Concrete Design A Fundamental Approach - Fifth Edition RETAINING WALLS Fifth Edition A. J. Clark School of Engineering Department of Civil and Environmental Engineering
Figure A-1. Figure A-2. continued on next page... HPM-1. Grout Reservoir. Neat Cement Grout (Very Flowable) Extension Displacement Plate
Addendum HELICAL PULLDOWN Micropile (HPM) Introduction The HPM is a system for constructing a grout column around the shaft of a standard Helical Screw Foundation (see Figure A1). To begin the process,
INSITU TESTS! Shear Vanes! Shear Vanes! Shear Vane Test! Sensitive Soils! Insitu testing is used for two reasons:!
In-situ Testing! Insitu Testing! Insitu testing is used for two reasons:! To allow the determination of shear strength or penetration resistance or permeability of soils that would be difficult or impossible
How To Design A Foundation
The Islamic university - Gaza Faculty of Engineering Civil Engineering Department CHAPTER (2) SITE INVESTIGATION Instructor : Dr. Jehad Hamad Definition The process of determining the layers of natural
How to Design Helical Piles per the 2009 International Building Code
ABSTRACT How to Design Helical Piles per the 2009 International Building Code by Darin Willis, P.E. 1 Helical piles and anchors have been used in construction applications for more than 150 years. The
vulcanhammer.net This document downloaded from
This document downloaded from vulcanhammer.net since 1997, your source for engineering information for the deep foundation and marine construction industries, and the historical site for Vulcan Iron Works
METHOD OF STATEMENT FOR STATIC LOADING TEST
Compression Test, METHOD OF STATEMENT FOR STATIC LOADING TEST Tension Test and Lateral Test According to the American Standards ASTM D1143 07, ASTM D3689 07, ASTM D3966 07 and Euro Codes EC7 Table of Contents
Comprehensive Design Example 2: Foundations for Bulk Storage Facility
Comprehensive Design Example 2: Foundations for Bulk Storage Facility Problem The project consists of building several dry product storage silos near an existing rail siding in an open field presently
System. Stability. Security. Integrity. 150 Helical Anchor
Model 150 HELICAL ANCHOR System PN #MBHAT Stability. Security. Integrity. 150 Helical Anchor System About Foundation Supportworks is a network of the most experienced and knowledgeable foundation repair
product manual HS-4210 HS-4210_MAN_09.08 Digital Static Cone Penetrometer
HS-4210_MAN_09.08 product manual HS-4210 Digital Static Cone Penetrometer Introduction This Manual covers the measurement of bearing capacity using the Humboldt Digital Static Cone Penetrometer (DSCP).
Design of reinforced concrete columns. Type of columns. Failure of reinforced concrete columns. Short column. Long column
Design of reinforced concrete columns Type of columns Failure of reinforced concrete columns Short column Column fails in concrete crushed and bursting. Outward pressure break horizontal ties and bend
Anirudhan I.V. Geotechnical Solutions, Chennai
Anirudhan I.V. Geotechnical Solutions, Chennai Often inadequate In some cases, excess In some cases, disoriented Bad investigation Once in a while good ones Depends on one type of investigation, often
Chapter 4 SUBSURFACE INVESTIGATION GUIDELINES
Chapter 4 SUBSURFACE INVESTIGATION GUIDELINES Final SCDOT GEOTECHNICAL DESIGN MANUAL August 2008 Table of Contents Section Page 4.1 Introduction...4-1 4.2 Subsurface Investigation...4-2 4.2.1 Preliminary
Helical Piles. A Practical Guide to Design and Installation
Brochure More information from http://www.researchandmarkets.com/reports/2216946/ Helical Piles. A Practical Guide to Design and Installation Description: An unbiased, comprehensive review of helical pile
Module 1 : Site Exploration and Geotechnical Investigation. Lecture 4 : In-situ tests [ Section 4.1: Penetrometer Tests ] Objectives
Lecture 4 : In-situ tests [ Section 4.1: Penetrometer Tests ] Objectives In this section you will learn the following Penetrometer Tests Standard penetration test Static cone penetration test Dynamic cone
Design and Construction of Auger Cast Piles
Design and Construction of Auger Cast Piles 101 th Annual Road School 2015 3/11/2015 Malek Smadi, Ph.D., P.E. Principal Engineer - GEOTILL - Fishers, IN [email protected] - www.geotill.com CONTENTS 1.
Module 7 (Lecture 24 to 28) RETAINING WALLS
Module 7 (Lecture 24 to 28) RETAINING WALLS Topics 24.1 INTRODUCTION 24.2 GRAVITY AND CANTILEVER WALLS 24.3 PROPORTIONING RETAINING WALLS 24.4 APPLICATION OF LATERAL EARTH PRESSURE THEORIES TO DESIGN 24.5
Lymon C. Reese & Associates LCR&A Consulting Services Tests of Piles Under Axial Load
Lymon C. Reese & Associates LCR&A Consulting Services Tests of Piles Under Axial Load Nature of Services The company has a long history of performance of tests of piles and pile groups under a variety
CEEN 162 - Geotechnical Engineering Laboratory Session 7 - Direct Shear and Unconfined Compression Tests
PURPOSE: The parameters of the shear strength relationship provide a means of evaluating the load carrying capacity of soils, stability of slopes, and pile capacity. The direct shear test is one of the
CIVL451. Soil Exploration and Characterization
CIVL451 Soil Exploration and Characterization 1 Definition The process of determining the layers of natural soil deposits that will underlie a proposed structure and their physical properties is generally
Outline MICROPILES SUBJECT TO LATERAL LOADING. Dr. Jesús Gómez, P.E.
MICROPILES SUBJECT TO LATERAL LOADING Dr. Jesús Gómez, P.E. Micropile Design and Construction Seminar Las Vegas, NV April 3-4, 2008 Outline When are micropiles subject to lateral load? How do we analyze
Page B-1 Hubbell Power Systems, Inc. All Rights Reserved Copyright 2014 LOAD TESTS
Page B-1 Hubbell Power Systems, Inc. All Rights Reserved Copyright 2014 Appendix B CONTENTS STATIC (TIEBACKS)... B-3 STATIC AXIAL (COMPRESSION/TENSION)... B-6 STATIC (LATERAL)... B-9 CAPACITY VERIFICATION
The demand for new roadway
Designing strong walls on weak soils Civil engineers have options to remedy foundation soil problems and meet project cost and schedule requirements. By Fadi Faraj, P.E.; Michael H. Garrison, P.E.; and
Geotechnical Investigation Reports and Foundation Recommendations - Scope for Improvement - Examples
Geotechnical Investigation Reports and Foundation Recommendations - Scope for Improvement - Examples Prof. V.S.Raju (Formerly: Director, IIT Delhi & Professor and Dean, IIT Madras) Email: [email protected]
Eurocode 7 - Geotechnical design - Part 2 Ground investigation and testing
Brussels, 18-20 February 2008 Dissemination of information workshop 1 Eurocode 7 - Geotechnical design - Part 2 Ground investigation and testing Dr.-Ing. Bernd Schuppener, Federal Waterways Engineering
CHAPTER 2 HYDRAULICS OF SEWERS
CHAPTER 2 HYDRAULICS OF SEWERS SANITARY SEWERS The hydraulic design procedure for sewers requires: 1. Determination of Sewer System Type 2. Determination of Design Flow 3. Selection of Pipe Size 4. Determination
load on the soil. For this article s examples, load bearing values given by the following table will be assumed.
How Many Piers? By Gary Collins, P.E. A clear-cut guide to helical pier spacing Introduction Helical pier spacing is not an exact science. How many does it take to support a structure adequately or repair
Geotechnical Measurements and Explorations Prof. Nihar Ranjan Patra Department of Civil Engineering Indian Institute of Technology, Kanpur
Geotechnical Measurements and Explorations Prof. Nihar Ranjan Patra Department of Civil Engineering Indian Institute of Technology, Kanpur Lecture No. # 13 (Refer Slide Time: 00:18) So last class, it was
KWANG SING ENGINEERING PTE LTD
KWANG SING ENGINEERING PTE LTD 1. INTRODUCTION This report represents the soil investigation works at Aljunied Road / Geylang East Central. The objective of the soil investigation is to obtain soil parameters
Local Authority Building Control Technical Information Note 3 Driven and In-situ Piled Foundations
Local Authority Building Control Technical Information Note 3 Driven and In-situ Piled Foundations Cambridge City Council - East Cambridgeshire District Council - Fenland District Council, Huntingdonshire
NEGATIVE SKIN FRICTION AND SETTLEMENT OF PILES. Dr. Bengt H. Fellenius, P. Eng. University of Ottawa, Canada
Fellenius, B. H., 1984. Negative skin friction and settlement of piles. Second International Seminar, Pile Foundations, Nanyang Technological Institute, Singapore, November 28-30, 12 p. NEGATIVE SKIN FRICTION
Micropiles Reduce Costs and Schedule for Merchant RR Bridge Rehabilitation
Micropiles Reduce Costs and Schedule for Merchant RR Bridge Rehabilitation Jeff R. Hill, P.E. Hayward Baker Inc. 111 W. Port Plaza Drive Suite 600 St. Louis, MO 63146 314-542-3040 [email protected]
SECTION 700 STRUCTURES SECTION 701 DRIVEN PILING MATERIALS. 701.02 Materials Materials shall be in accordance with the following:
701.03 SECTION 700 STRUCTURES SECTION 701 DRIVEN PILING 10 701.01 Description This work shall consist of furnishing and driving foundation piles of the type and dimensions specified including cutting off
c. Borehole Shear Test (BST): BST is performed according to the instructions published by Handy Geotechnical Instruments, Inc.
Design Manual Chapter 6 - Geotechnical 6B - Subsurface Exploration Program 6B-2 Testing A. General Information Several testing methods can be used to measure soil engineering properties. The advantages,
Engineered, Time-Tested Foundation Repairs for Settlement in Residential and Light Commercial Structures. The Leading Edge.
TM TM Engineered, Time-Tested Foundation Repairs for Settlement in Residential and Light Commercial Structures. SM The Leading Edge. 10 One Major Causes of foundation settlement or more conditions may
Design of Steel Structures Prof. S.R.Satish Kumar and Prof. A.R.Santha Kumar. Fig. 7.21 some of the trusses that are used in steel bridges
7.7 Truss bridges Fig. 7.21 some of the trusses that are used in steel bridges Truss Girders, lattice girders or open web girders are efficient and economical structural systems, since the members experience
USE OF MICROPILES IN TEXAS BRIDGES. by John G. Delphia, P.E. TxDOT Bridge Division Geotechnical Branch
USE OF MICROPILES IN TEXAS BRIDGES by John G. Delphia, P.E. TxDOT Bridge Division Geotechnical Branch DEFINITION OF A MICROPILE A micropile is a small diameter (typically less than 12 in.), drilled and
STRUCTURES. 1.1. Excavation and backfill for structures should conform to the topic EXCAVATION AND BACKFILL.
STRUCTURES 1. General. Critical structures may impact the integrity of a flood control project in several manners such as the excavation for construction of the structure, the type of foundation, backfill
National Council of Examiners for Engineering and Surveying. Principles and Practice of Engineering Structural Examination
Structural Effective Beginning with the April 2011 The structural engineering exam is a breadth and exam examination offered in two components on successive days. The 8-hour Vertical Forces (Gravity/Other)
PILE FOUNDATION CONSTRUCTION INSPECTION
ILLINOIS DEPARTMENT OF TRANSPORTATION SPECIFIC TASK TRAINING PROGRAM PILE FOUNDATION CONSTRUCTION INSPECTION S 19 CLASS REFERENCE GUIDE Reference Guide Available online at: http://www.dot.il.gov/bridges/geotechtraining.html
Formwork for Concrete
UNIVERSITY OF WASHINGTON DEPARTMENT OF CONSTRUCTION MANAGEMENT CM 420 TEMPORARY STRUCTURES Winter Quarter 2007 Professor Kamran M. Nemati Formwork for Concrete Horizontal Formwork Design and Formwork Design
Steel joists and joist girders are
THE STEEL CONFERENCE Hints on Using Joists Efficiently By Tim Holtermann, S.E., P.E.; Drew Potts, P.E.; Bob Sellers, P.E.; and Walt Worthley, P.E. Proper coordination between structural engineers and joist
TYPES OF PIERS USED IN NORTH AND EAST TEXAS RESIDENTIAL FOUNDATION REPAIR
TYPES OF PIERS USED IN NORTH AND EAST TEXAS RESIDENTIAL FOUNDATION REPAIR If you listen to the hype, it sounds like there must be 20 or 30 different types of piers out there. Company A says they have an
GUIDELINE FOR HAND HELD SHEAR VANE TEST
GUIDELINE FOR HAND HELD SHEAR VANE TEST NZ GEOTECHNICAL SOCIETY INC August 2001 CONTENTS Page 1.0 Introduction 2 2.0 Background 2 3.0 Recommended Practice 3 4.0 Undrained Shear Strength 3 5.0 Particular
SPECIFICATION FOR DYNAMIC CONSOLIDATION / DYNAMIC REPLACEMENT
SPECIFICATION FOR DYNAMIC CONSOLIDATION / DYNAMIC REPLACEMENT 1.0 SOIL IMPROVEMENT 1.1 General Soil Investigation Information are provided in Part B1 annex as a guide to the Contractor for his consideration
COMPENDIUM OF INDIAN STANDARDS ON SOIL ENGINEERING PART 2
(PREVIEW) SP 36 (Part 2) : 1988 COMPENDIUM OF INDIAN STANDARDS ON SOIL ENGINEERING PART 2 IS 1893 : 1979 (Reaffirmed 1987) CODE OF PRACTICE FOR SUBSURFACE INVESTIGATION FOR FOUNDATIONS 1.1 This code deals
ATLAS RESISTANCE Pier Foundation Systems
ATLAS RESISTANCE Pier Foundation Systems Foundation Repair Systems for Civil Construction Applications: Residential, Commercial, Industrial Atlas Resistance Piers have been used to restore and/or stabilize
Safe & Sound Bridge Terminology
Safe & Sound Bridge Terminology Abutment A retaining wall supporting the ends of a bridge, and, in general, retaining or supporting the approach embankment. Approach The part of the bridge that carries
Earth Pressure and Retaining Wall Basics for Non-Geotechnical Engineers
PDHonline Course C155 (2 PDH) Earth Pressure and Retaining Wall Basics for Non-Geotechnical Engineers Instructor: Richard P. Weber, P.E. 2012 PDH Online PDH Center 5272 Meadow Estates Drive Fairfax, VA
SEISMIC DESIGN. Various building codes consider the following categories for the analysis and design for earthquake loading:
SEISMIC DESIGN Various building codes consider the following categories for the analysis and design for earthquake loading: 1. Seismic Performance Category (SPC), varies from A to E, depending on how the
Load and Resistance Factor Geotechnical Design Code Development in Canada. by Gordon A. Fenton Dalhousie University, Halifax, Canada
Load and Resistance Factor Geotechnical Design Code Development in Canada by Gordon A. Fenton Dalhousie University, Halifax, Canada 1 Overview 1. Past: Where we ve been allowable stress design partial
SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 11/5/13)
Page 1 of 7 STONE STRONG SYSTEMS SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised ) PART 1: GENERAL 1.01 Description A. Work includes furnishing and installing precast modular blocks
High Strain Dynamic Load Testing of Drilled Shafts
Supplemental Technical Specification for High Strain Dynamic Load Testing of Drilled Shafts SCDOT Designation: SC-M-712 (9/15) September 3, 2015 1.0 GENERAL This work shall consist of performing high-strain
Module 5 (Lectures 17 to 19) MAT FOUNDATIONS
Module 5 (Lectures 17 to 19) MAT FOUNDATIONS Topics 17.1 INTRODUCTION Rectangular Combined Footing: Trapezoidal Combined Footings: Cantilever Footing: Mat foundation: 17.2 COMMON TYPES OF MAT FOUNDATIONS
TECHNICAL NOTE Lining of Casings with SaniTite HP Pipe
TECHNICAL NOTE Lining of Casings with SaniTite HP Pipe TN 5.18 October 2015 In sanitary sewer, it is often necessary to use trenchless technology methods to install a casing pipe under high volume roads,
Design, Testing and Automated Monitoring of ACIP Piles in Residual Soils
Design, Testing and Automated Monitoring of ACIP Piles in Residual Soils Stephen W. Lacz 1, M. ASCE, P.E. and Richard C. Wells 2, F. ASCE, P.E. 1 Senior Professional, Trigon Kleinfelder, Inc., 313 Gallimore
The Stabilizer TM. Benefits. www.griptite.com. Supplemental support system for sagging beams and floor joists within a crawl space
The Stabilizer TM Supplemental support system for sagging beams and floor joists within a crawl space Pre-drilled holes in steel plate allow for connection to beam or floor joists. Benefits Levels and
4.3.5 - Breakaway Walls
4.3.5 - Breakaway Walls Elevation of a structure on a properly designed foundation reduces the potential for water damage from flooding. When the space below the lowest elevated floor is maintained free
Pavements should be well drained both during and upon completion of construction. Water should not be allowed to pond on or near pavement surfaces.
Project No. 208-8719 January, 2009 Ref: 2-8719BR Anthony Hudson - Broadscale Geotechnical Investigation - Proposed Commercial Development - 52 Old Pacific Highway, Pimpama Page 32 iii) Pavements should
Specification Guidelines: Allan Block Modular Retaining Wall Systems
Specification Guidelines: Allan Block Modular Retaining Wall Systems The following specifications provide Allan Block Corporation's typical requirements and recommendations. At the engineer of record's
Optimum proportions for the design of suspension bridge
Journal of Civil Engineering (IEB), 34 (1) (26) 1-14 Optimum proportions for the design of suspension bridge Tanvir Manzur and Alamgir Habib Department of Civil Engineering Bangladesh University of Engineering
June 2007 CHAPTER 7 - CULVERTS 7.0 CHAPTER 7 - CULVERTS 7.1 GENERAL
7.0 7.1 GENERAL For the purpose of this manual, culverts are defined as structures that are completely surrounded by soil and located below the surface of the roadway parallel to the general direction
BUTE Department of Construction Management and Technology
BUTE Department of Construction Management and Technology 02.10.2012 Definition 1: Foundation: The structure, that transmits the load of the building to the soil Definition 2: Load bearing soil (strata):
FOUNDATION DESIGN. Instructional Materials Complementing FEMA 451, Design Examples
FOUNDATION DESIGN Proportioning elements for: Transfer of seismic forces Strength and stiffness Shallow and deep foundations Elastic and plastic analysis Foundation Design 14-1 Load Path and Transfer to
GEOTECHNICAL ENGINEERING FORMULAS. A handy reference for use in geotechnical analysis and design
GEOTECHNICAL ENGINEERING FORMULAS A handy reference for use in geotechnical analysis and design TABLE OF CONTENTS Page 1. SOIL CLASSIFICATION...3 1.1 USCS: Unified Soil Classification System...3 1.1.1
ENCE 4610 Foundation Analysis and Design
This image cannot currently be displayed. ENCE 4610 Foundation Analysis and Design Shallow Foundations Total and Differential Settlement Schmertmann s Method This image cannot currently be displayed. Strength
SECTION 1 GENERAL REQUIREMENTS
Page 1 of 6 SECTION 1 GENERAL REQUIREMENTS 1. SCOPE OF WORK: The work to be performed under the provisions of these documents and the contract based thereon includes furnishing all labor, equipment, materials,
Figure 2.31. CPT Equipment
Soil tests (1) In-situ test In order to sound the strength of the soils in Las Colinas Mountain, portable cone penetration tests (Japan Geotechnical Society, 1995) were performed at three points C1-C3
Drained and Undrained Conditions. Undrained and Drained Shear Strength
Drained and Undrained Conditions Undrained and Drained Shear Strength Lecture No. October, 00 Drained condition occurs when there is no change in pore water pressure due to external loading. In a drained
PILE TESTING SPECIFICATION
PILE TESTING SPECIFICATION 1.0 GENERAL This specification deals with the testing of a pile by the application of an axial load or force. It covers vertical and raking piles tested in compression (i.e.
CH. 2 LOADS ON BUILDINGS
CH. 2 LOADS ON BUILDINGS GRAVITY LOADS Dead loads Vertical loads due to weight of building and any permanent equipment Dead loads of structural elements cannot be readily determined b/c weight depends
New construction Repairing failed or old foundations Retrofit foundations Permanent battered piers Machinery/equipment foundations
from New construction foundations don t have to be a headache. The CHANCE Helical Pier Foundation System gives you the performance of concrete without the drawbacks and liabilities of driven piles and
EXAMPLE 1 DESIGN OF CANTILEVERED WALL, GRANULAR SOIL
EXAMPLE DESIGN OF CANTILEVERED WALL, GRANULAR SOIL A sheet pile wall is required to support a 2 excavation. The soil is uniform as shown in the figure. To take into account the friction between the wall
Report on. Wind Resistance of Signs supported by. Glass Fiber Reinforced Concrete (GFRC) Pillars
Report on Wind Resistance of Signs supported by Glass Fiber Reinforced Concrete (GFRC) Pillars Prepared for US Sign and Fabrication Corporation January, 2006 SUMMARY This study found the attachment of
PDHonline Course S151A (1 PDH) Steel Sheet Piling. Instructor: Matthew Stuart, PE, SE. PDH Online PDH Center
PDHonline Course S151A (1 PDH) Steel Sheet Piling Instructor: Matthew Stuart, PE, SE 2012 PDH Online PDH Center 5272 Meadow Estates Drive Fairfax, VA 22030-6658 Phone & Fax: 703-988-0088 www.pdhonline.org
Ohio Department of Transportation Division of Production Management Office of Geotechnical Engineering. Geotechnical Bulletin PLAN SUBGRADES
Ohio Department of Transportation Division of Production Management Office of Geotechnical Engineering Geotechnical Bulletin GB 1 PLAN SUBGRADES Geotechnical Bulletin GB1 was jointly developed by the Offices
SUPPLEMENTAL TECHNICAL SPECIFICATIONS BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS
July 14, 2015 1.0 GENERAL BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS This work shall consist of furnishing all materials, equipment, labor, and incidentals necessary for conducting bi-directional
SECTION 5 ANALYSIS OF CONTINUOUS SPANS DEVELOPED BY THE PTI EDC-130 EDUCATION COMMITTEE LEAD AUTHOR: BRYAN ALLRED
SECTION 5 ANALYSIS OF CONTINUOUS SPANS DEVELOPED BY THE PTI EDC-130 EDUCATION COMMITTEE LEAD AUTHOR: BRYAN ALLRED NOTE: MOMENT DIAGRAM CONVENTION In PT design, it is preferable to draw moment diagrams
Underpinning Systems 14.1 FOUNDATION REPAIR. Helical Piles
Helical Piles Howard A. Perko Copyright 0 2009 by John Wiley & Sons, Inc. All rights reserved. C h a p t e r 14 Underpinning Systems There has been tremendous growth in the use of helical piles for underpinning
Draft Table of Contents. Building Code Requirements for Structural Concrete and Commentary ACI 318-14
Draft Table of Contents Building Code Requirements for Structural Concrete and Commentary ACI 318-14 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE (ACI 318 14) Chapter 1 General 1.1 Scope of ACI 318
STATIC PILE LOAD TEST MANUAL. GEOTECHNICAL CONTROL PROCEDURE GCP-18 Revision #4
STATIC PILE LOAD TEST MANUAL GEOTECHNICAL CONTROL PROCEDURE GCP-18 Revision #4 AUGUST 2015 GEOTECHNICAL CONTROL PROCEDURE: STATIC PILE LOAD TEST MANUAL GCP-18 Revision #4 STATE OF NEW YORK DEPARTMENT
Stability. Security. Integrity.
Stability. Security. Integrity. PN #MBHPT Foundation Supportworks provides quality helical pile systems for both new construction and retrofit applications. 288 Helical Pile System About Foundation Supportworks
GRADATION OF AGGREGATE FOR CONCRETE BLOCK
GRADATION OF AGGREGATE FOR CONCRETE BLOCK Although numerous papers have been written concerning the proper gradation for concrete mixes, they have generally dealt with plastic mixes, and very little published
Lighthouse Engineering, L.L.C.
Registered Engineering Firm (F: 9334) Phone: 214-577-1077 Fax: 214-224-0549 Website: www.lighthouseeng.com Email: [email protected] Thursday, September 04, 2014 TO: Our Client RE: Initial Engineering
Tremie Concrete CM 420 CM 420 CM 420 CM 420. Temporary Structures. Tremie Concrete
Tremie Concrete Underwater concrete plays an important role in the construction of offshore structures. It may be used to tie together various elements in composite action (i.e., to tie piling to the footing).
SUGGESTION ABOUT DETERMINATION OF THE BEARING CAPACITY OF PILES ON THE BASIS OF CPT SOUNDING TESTS
SUGGESTION ABOUT DETERMINATION OF THE BEARING CAPACITY OF PILES ON THE BASIS OF CPT SOUNDING TESTS JóZSEF PUSZTAI About the authors Pusztai József Budapest University of Technology and Economics, Department
6 RETROFITTING POST & PIER HOUSES
Retrofitting Post & Pier Houses 71 6 RETROFITTING POST & PIER HOUSES by James E. Russell, P.E. 72 Retrofitting Post & Pier Houses Retrofitting Post & Pier Houses 73 RETROFITTING POST AND PIER HOUSES This
Standard Test Method for Mechanical Cone Penetration Tests of Soil 1
Designation: D 3441 98 AMERICAN SOCIETY FOR TESTING AND MATERIALS 100 Barr Harbor Dr., West Conshohocken, PA 19428 Reprinted from the Annual Book of ASTM Standards. Copyright ASTM Standard Test Method
A study on the Effect of Distorted Sampler Shoe on Standard Penetration Test Result in Cohesionless soil
ISSN: 319-53 (An ISO 39: 00 Certified Organization) A study on the Effect of Distorted Sampler Shoe on Standard Penetration Test Result in Cohesionless soil Utpal Kumar Das Associate Professor, Department
III. Compression Members. Design of Steel Structures. Introduction. Compression Members (cont.)
ENCE 455 Design of Steel Structures III. Compression Members C. C. Fu, Ph.D., P.E. Civil and Environmental Engineering Department University it of Maryland Compression Members Following subjects are covered:
Shaft- Mounted Speed Reducers
Torque Arm Design Considerations for Todd R. Bobak has worked in the gear industry for 15 years. He has held positions in technical service, design and development, and quality assurance. He is a product
EN 1997-1 Eurocode 7. Section 10 Hydraulic Failure Section 11 Overall Stability Section 12 Embankments. Trevor L.L. Orr Trinity College Dublin Ireland
EN 1997 1: Sections 10, 11 and 12 Your logo Brussels, 18-20 February 2008 Dissemination of information workshop 1 EN 1997-1 Eurocode 7 Section 10 Hydraulic Failure Section 11 Overall Stability Section