Installation Guide Chromeleon 7.2
|
|
|
- Mavis Brown
- 10 years ago
- Views:
Transcription
1 Chromeleon Revision 1.0 July 2013
2 Table of Contents 1 About the Documentation About this Document Document Conventions Other Documents System Requirements / Compatibility Licensing Requirements / Compatibility The License File License Key (Dongle) Compatibility License File Compatibility Supported Chromatography Instruments and Modules Firmware Requirements PC Hardware Requirements Supported Operating Systems Microsoft Windows Microsoft Windows Vista Microsoft Windows XP Windows Service Packs Windows Security Updates Database Support Microsoft SQL Server Express Edition Required Third-Party Software Windows Installer Dionex Chromeleon 7 Shared Components Microsoft.NET Framework Microsoft Chart Controls for Microsoft.NET Framework Microsoft SQL Server Express Microsoft Visual C++ Redistributable MSXML WibuKey Software Amyuni PDF Converter...14 Page i
3 2.7 Software for Controlling Specific Third-Party Instruments CTC Analytics Instruments Components Agilent Instrument Control Framework (ICF) and LC Driver Package Rheodyne MXII Series Valves Driver Waters Acquity UPLC System Instrument Driver Configuring Windows for Chromeleon Ensuring that Windows is up to Date Non-Internet connected computers Firewall Settings Disabling Power Management Disabling Windows Power Management Disabling USB Power Management Third-Party Software Interference Compatibility with Previous Chromeleon and PeakNet Versions Software Compatibility Chromeleon 7 and Software Compatibility Chromeleon 7.2 and Data Compatibility Chromeleon 7 and Data Compatibility Chromeleon 7.2 and 7.1 SR Installing the Software Do you have Chromeleon 6? Installing Chromeleon Installing Software for Controlling Specific Third-Party Instruments Installation Qualification Activating / Updating a License Using a New Chromeleon 7 License Key that Contains a License File Using an Empty License Key and a Separate License File...38 Page ii
4 5.6 Troubleshooting Software Installation Errors which Stop Installation Repairing an Installation Installation Process Details Manual Installation of Third-Party Software Components Installing Thermo Scientific Dionex Instruments Connecting Modules via USB Loading the USB Driver for a Module Troubleshooting USB Issues Configuring Chromeleon Starting Points for Configuring Chromeleon Chromeleon Services Manager Chromeleon Tray Icon Chromeleon Administration Console Configuring Instruments / Modules Enabling Automatic Start of the Instrument Controller Service Configuring Data Vaults Default Data Vault, XVault, and Default Location The Data Vault Manager Creating a Standard Data Vault Mounting Chromeleon 6 Datasources Enabling and Configuring User Management Licensing Removing Chromeleon 7 from a PC Uninstalling Chromeleon Uninstalling Third-Party Software Removing Chromeleon 7 Data...73 Page iii
5 Copyright Copyright 2013 Thermo Fisher Scientific The information contained in this document is subject to change without notice. All rights reserved including those for photomechanical reproduction and storage on electronic media. No part of this publication may be copied or distributed, transmitted, transcribed, stored in a retrieval system, or transmitted into any human or computer language, in any form or by any means, electronic, mechanical, magnetic, manual, or otherwise, or disclosed to third parties without the express written permission of Thermo Fisher Scientific Inc. Trademarks Amyuni PDF Converter is owned by Amyuni. WibuKey is owned by Wibu-Systems. Intel Core and Intel Pentium are trademarks of Intel Corporation. Aquity is a trademark of the Waters Corporation. Rheodyne MX II Series is a trademark of Rheodyne LLC/Idex Health & Science Group. Windows, Windows Vista, SQL Server 2008, SQL Server, and Microsoft are registered trademarks of Microsoft Corporation. Sycnfusion is a trademark of Syncfusion Inc. Log4Net is a trademark of The Apache Software Foundation. Mono is a trademark of Novell Inc. All other trademarks are property of Thermo Fisher Scientific Inc. and its subsidiaries. Page iv
6 1 About the Documentation 1.1 About this Document This guide provides instructions for performing the following operations on stand-alone Chromeleon TM stations: installing / updating Chromeleon 7 and required 3 rd party software components basic configuration of Chromeleon 7 including basic instructions for installing instruments configuring Windows to suit Chromeleon 7 It also describes: hardware and software requirements for installing Chromeleon 7 software and data compatibility with previous Chromeleon versions If you are installing multiple workstations that will be networked together, or adding a station to an existing networked installation, please contact the Thermo Fisher Scientific Service for Dionex Chromatography Software for support. 1.2 Document Conventions The following formatting is used throughout the document to indicate text with special importance. Page 1
7 Caution: Indicates text that must be followed carefully to avoid potential problems. Note: Indicates information of special interest. Tip: Indicates information that will help you to use the software more efficiently. 1.3 Other Documents Other documents provided with Chromeleon will help you to learn more about the software. Their scope is described in the Document Overview, which is included with the Chromeleon installation media in printed form. The documents are also available in electronic form on the installation disk in the Documents folder. Tip: The Glossary describes Chromeleon-specific terms and common abbreviations used throughout the documentation. Page 2
8 2 System Requirements / Compatibility 2.1 Licensing Requirements / Compatibility In order to use Chromeleon you must have a valid license matching the software version you are about to install. A Chromeleon 7 license has two components: - a hardware component called a USB License Key (dongle), and - a License File that contains the license information. To activate a valid license, the two components must have the same serial number and must be present at the same time. You will be asked to insert the License Key and to provide a License File during the software installation process (section 5.2). If you do not have them at hand, you can also activate a license later as described in section The License Key The License Key is a USB device that (together with a matching License File) allows Chromeleon software to be used on the computer where the License Key is present. Caution: The License Key represents your purchase of Chromeleon. Protect it as you would protect any other valuable object. The License Key can be either a new (light blue) Chromeleon 7 USB device, or a prior-generation (green) Chromeleon 6 USB dongle. At the time of delivery, new (light blue) License Keys normally contain the corresponding License File. The License File is Page 3
9 automatically (without warning) moved to the computer the first time the License Key is connected to a computer where Chromeleon 7 is present. Caution: When a light blue License Key is new, do not connect it to a computer other than the one where it will be used. If the license file is moved to a wrong computer, the license file must be manually moved to the computer where it will be finally used The License File The License File contains the license information, such as the software version and the purchased software options. The name of the License File is Chromeleon7_xxxxxx.cmlic, where xxxxxx is the serial number of the license. Tip: The information below is for reference/troubleshooting only; the License File is automatically moved/copied to the appropriate location during the setup/license activation. The license file is stored in the following location: Windows XP: C:\Documents and Settings\All Users\Application Data\ Dionex\Chromeleon\ Windows Vista / Windows 7: C:\ProgramData\Dionex\Chromeleon\ Note: The paths above contain folders that are hidden by default. If you need to see them, follow instructions in Windows Help on how to display hidden files and folders. Page 4
10 2.1.3 License Key (Dongle) Compatibility Chromeleon 7 has a different licensing mechanism compared to Chromeleon 6.8 and older releases, including all PeakNet 6 releases. It still uses a USB License Key (dongle), but instead of using a key code, Chromeleon 7 requires installation of a matching License File. The most recent generation of Chromeleon 6 License Keys (green USB dongles) can be used with Chromeleon 7, when a matching License File is available License File Compatibility Chromeleon 7 License Files are bound to main versions of Chromeleon. For example a License File that was provided with version 7.0 will support 7.0 SR1, but will not work with version 7.1. For the latter an upgrade must be purchased. The updated License File will be provided with the upgrade. 2.2 Supported Chromatography Instruments and Modules Chromeleon 7 provides full control of most of the current Thermo Scientific Dionex instruments. In addition, some third party instruments are also supported. For details, please refer to the List of Supported Instruments in the Documents folder of the installation disk Firmware Requirements The List of Supported Instruments (in the Documents folder of the installation disk) lists the firmware versions recommended for using various instruments with Chromeleon 7.2. Page 5
11 2.3 PC Hardware Requirements The table below shows the minimum and the recommended PC configuration for a stand-alone installation of Chromeleon 7.2. PCs meeting minimum requirements may be sufficient for some low-demand applications, but will not provide satisfactory performance in many applications. PCs meeting recommended requirements should be suitable for general applications. Processor Minimum: 2.0 GHz Intel Pentium 4 class With 1 DAD-3000RS: 3 GHz Intel Core 2 Duo With 2 DAD-3000RS: 3 GHz Intel Core i7* With GC-MS: 2.4 GHz Recommended: 3 GHz Intel Core i7* or better RAM Minimum: 2 GB With 1 DAD-3000RS: 3 GB With 2 DAD-3000RS: 4 GB* With GC-MS: 4 GB Recommended: 4 GB or more* Hard Disk Minimum: 60 GB** Systems with 3D detector(s): 120 GB** DAD-3000RS with 15 MB / min max (200 Hz) rate GC-MS systems: 250 GB Optical Drive DVD Page 6
12 Display Minimum: 1024 x 768 resolution 32-bit color Recommended: 1280 x 1024 or 1440 x 900 or higher resolution 32-bit color USB Ports For license device: 1 port For connecting Thermo Scientific Dionex modules: MWD-3000(RS) and DAD-3000(RS) 1 or more additional port(s) Require USB 2.0 speed * For taking full advantage of this hardware a 64-bit Windows version is required. ** These hard disk requirements are set to enable storage of a substantial amount of data. The software itself requires approximately 3 GB disk space on the C drive (twice as much during an update). In addition, a few GB disk space must always be available on the C drive for Sequences cached in the XVault (see section 7.4.1). Caution: Please check with Thermo Fisher Scientific to determine any additional requirements for the instruments you want to connect, for example expansion slots for controlling third party instruments via RS-232 or GPIB. Caution: For running Chromeleon on 64-bit Windows, a computer with the Recommended specifications is required at minimum. Page 7
13 Tip: Please contact Thermo Fisher Scientific for details about requirements for installing Chromeleon in a network. 2.4 Supported Operating Systems Chromeleon 7.2 has been validated for stand-alone use on the operating systems listed below. Windows 8 has currently not yet adequately been tested to confirm proper operation with Chromeleon. Tip: Chromeleon 7 can also be installed on server operating systems (Windows Server versions). Please contact Thermo Fisher Scientific for details Microsoft Windows 7 Chromeleon 7.2 was tested with 32-bit and 64-bit versions of Microsoft Windows 7 SP1 Professional and Windows 7 Ultimate editions Microsoft Windows Vista It is possible to install and use Chromeleon 7.2 on 32-bit editions of Microsoft Windows Vista Business SP2 and Windows Vista Ultimate; SP2 is required at minimum. However, this combination has NOT been formally validated, thus it is NOT recommended by Thermo Fisher Scientific. Page 8
14 2.4.3 Microsoft Windows XP Chromeleon 7.2 was tested on SP3 of Microsoft Windows XP Professional (32-bit). It will not install on previous versions of Windows XP. Tip: Microsoft support for Windows XP is ending on April 8, Thermo Fisher Scientific therefore recommends upgrading existing Chromeleon installations to Windows 7 before that date. We do not recommend using Windows XP for new Chromeleon installations Windows Service Packs For security reasons, Thermo Fisher Scientific generally recommends installing the latest Windows service pack on your operating system. However, conflicts between Chromeleon releases and subsequent Windows service packs are possible. Caution: Before installing Windows service packs different from those than recommended in this document, always consult with Thermo Fisher Scientific or check the Thermo Fisher Scientific web site for Dionex products ( Chromeleon is tested with the latest Windows service packs. Information and/or Chromeleon updates are provided as required Windows Security Updates For optimum security, it is recommended that you keep your systems up to date with the latest security updates. The risk Page 9
15 that a security update itself might interfere with Chromeleon is generally low. However, the update process may interfere with operation of Chromeleon. For example database transactions could be interrupted by updating SQL Server Express, and instrument control can be interrupted by updating related system components. Caution: Thermo Fisher Scientific recommends to use the Download updates for me, but let me choose when to install them option for automatic Windows updates and choosing an installation time when Chromeleon is closed and no data acquisition is taking place in the background. Notes: Thermo Fisher Scientific will not formally validate Windows security updates. Installation and testing of security updates is in the user s own responsibility. If you find any compatibility issue when testing a Windows Security Update, please contact the Thermo Fisher Scientific Service for Dionex Chromatography Software for support. Although we will make reasonable efforts to solve such problems, we cannot guarantee compatibility with every security update. Security updates should generally be installed as soon as practicable, in order to keep the window of vulnerability small. Security updates should be briefly tested in the context of the laboratory s installation and operating procedures. Thermo Fisher Scientific recommends the following test procedure to ensure software integrity: Install the security update and Chromeleon on a test PC Qualify the Chromeleon Station: Run a Chromeleon Installation Qualification (IQ) and a Chromeleon Operational Qualification Page 10
16 (OQ). You can start the Station Qualification from the Tools menu of the Console. You can read more about Station Qualification in the Chromeleon 7 Help: Administrating Chromeleon > Station Qualification. Perform further PQ tests according to the routines in your lab. 2.5 Database Support Microsoft SQL Server Express Edition Chromeleon 7.2 uses Microsoft SQL Server Express Edition as the database engine for Standard (local) Data Vaults. If SQL Server Express is not already present, SQL Server 2008 R2 Express Edition SP2 is installed automatically during the Chromeleon setup, including the necessary server and client components and the corresponding Software Development Kit (SDK). This takes place before the actual Chromeleon 7 installation starts. If an earlier version of SQL Server 2008 R2 Express or if a SQL Server 2005 Express version is present, the SQL Server will NOT be updated automatically. The Chromeleon Installation Qualification (see section 5.4) reports the installed SQL Server version, and the IQReport will contain a Warning if a different version than SQL Server 2008 R2 SP2 was found. If desired, SP2 can be installed by starting the corresponding setup manually as described in section Chromeleon 7.2 has been validated to work with the following versions of Microsoft SQL Server components: SQL Server 2005 Express Edition, SP3, Version SQL Server 2008 R2 Express Edition SP2, Version SQL Server Native Client, Version Page 11
17 Note: Chromeleon 7 has not yet been validated to work with SQL Server 2008 and 2012 Express. Note: Chromeleon 7.2 only supports creating Standard Data Vaults locally on the hard drive of the PC that runs Chromeleon 7. Standard Data Vaults can be shared over the network, but the connectivity, performance, and capacity are limited by SQL Server Express. Tip: Chromeleon also supports other, multi-user optimized databases, namely Oracle and the multi-user (non-express) edition of MS SQL Server. Please contact Thermo Fisher Scientific for details. 2.6 Required Third-Party Software Note: The sections below are provided for reference only. If not already present, the required third-party software components are installed automatically during the setup. The Chromeleon Installation Qualification (IQ, section 5.4) reports the status of many of these components. Should you experience problems with any of the third party software components, refer to section 5.6 for troubleshooting hints Windows Installer Chromeleon 7.2 requires and installs Windows Installer version 4.5 or higher for the setup. Page 12
18 2.6.2 Dionex Chromeleon 7 Shared Components Chromeleon Shared 7 Components is a bundle of products used by Chromeleon, Chromeleon services, and the Chromeleon Software Development Kit (SDK). These products are installed in a central repository; the Global Assembly Cache. Chromeleon 7 Shared component have a separate installer to Chromeleon, allowing you to retain these products if Chromeleon is uninstalled. Chromeleon 7 Shared Components contains the following products: Sycnfusion version (User Interface components used by Chromeleon and the SDK) Log4Net version (Open Source Logging library used by Chromeleon, the Chromeleon services, and the SDK) Microsoft.NET Framework Chromeleon 7.2 requires and installs Microsoft.NET Framework, version 3.5 SP1 and Microsoft Chart Controls for Microsoft.NET Framework Chromeleon 7.2 requires and installs Microsoft Chart Controls for Microsoft.NET Framework, version 3.5 SP Microsoft SQL Server Express Chromeleon 7.2 uses Microsoft SQL Server 2008 R2 Express Edition (including the Software Development Kit (SDK)) as the database engine for working with Standard (local) Data Vaults. For details on the validated versions, refer to chapter above. Page 13
19 2.6.6 Microsoft Visual C++ Redistributable Chromeleon 7.2 requires Microsoft Visual C++ Runtime Environment Version2010. Some 3 rd party instrument drivers require Microsoft Visual C++ Runtime Environment Version 2005 SP1 and 2008 SP MSXML Chromeleon 7.2 requires MSXML Version 4 SP WibuKey Software Chromeleon 7.2 uses the WibuKey software version 6.11 as part of the software licensing infrastructure Amyuni PDF Converter Chromeleon 7.2 uses the Amyuni PDF Converter version for exporting results in PDF format. Note: The version of Amyuni PDF Converter, provided as part of Chromeleon, is licensed for use with Chromeleon only. 2.7 Software for Controlling Specific Third-Party Instruments This section lists software components that are necessary for controlling certain third-party instruments. Page 14
20 2.7.1 CTC Analytics Instruments Components This software is required for controlling of CTC Analytics instruments. It is part of the Chromeleon 7 setup and is installed automatically. The Chromeleon Instrument Configuration Manager Help chapter Installing Third-Party Modules CTC Analytics PAL LC and GC Samplers contains installation instructions. The following software components are not installed automatically; they have to be installed manually to enable support of the corresponding instruments Agilent Instrument Control Framework (ICF) and LC Driver Package This software must be installed for controlling Agilent liquid chromatographs from Chromeleon (it is NOT required for controlling Agilent GCs). The Drivers folder of the Chromeleon installation disk contains the ICF and LC Driver versions that were tested and were current at the time of releasing Chromeleon 7.2. The Drivers folder also contains a ReadMe file with installation instructions. In addition, the Chromeleon and Agilent ICF - Quick Start Guide in the Documents folder provides further installation details, explains the basics on how to configure the systems and how to get started. The Agilent LC driver replaces the Agilent 1100 and 1200 drivers which are obsolete and will no longer be maintained. Tip: The Agilent web site provides information about which modules can be controlled via ICF: Page 15
21 services/instruments-systems/liquid- Chromatography/Pages/specificationsicf.aspx Rheodyne MXII Series Valves Driver This software is necessary to communicate with Rheodyne MXII Series Valves over USB. The USB Virtual COM Port folder provided in the Drivers folder of the Chromeleon installation disk contains the driver version that was tested and was current at the time of releasing Chromeleon 7.2. The USB Virtual COM Port folder also contains a readme file with installation instructions Waters Acquity UPLC System Instrument Driver This software must be installed for controlling Waters Acquity UPLC system modules. The Drivers folder of the Chromeleon installation disk contains the driver version that was tested and was current at the time of releasing Chromeleon 7.2. The Chromeleon Instrument Configuration Manager Help chapter Installing Third-Party Modules Waters Acquity UPLC System contains installation instructions. Tip: The List of Supported Instruments in the Documents folder of the Chromeleon installation disk provides details about which Waters modules can be controlled from Chromeleon and for which of them it is necessary to install the Acquity driver. Page 16
22 3 Configuring Windows for Chromeleon 7 This chapter describes how to prepare Windows for correct operation of Chromeleon Ensuring that Windows is up to Date It is recommended that before installing Chromeleon 7 you ensure that Windows is fully up to date. If you have a new installation of Windows, or have previously set Windows not to update automatically, you should enable Windows Update and wait until all updates have successfully installed before installing Chromeleon 7. Caution: Changing the name or network path of the computer after installing Chromeleon 7 will result in inaccessibility of data vaults. It is therefore recommended that the computer name and path be defined before installing Chromeleon 7. If you need to change the computer name after the installation of Chromeleon, please contact Thermo Fisher Scientific Service for Dionex Chromatography Software for support Non-Internet connected computers Automatic Windows updates and patches are not possible for computers that do not have an Internet connection. Page 17
23 Caution: For Windows XP computers that are not connected to the Internet, it is essential that at least the latest Microsoft "Update for Root Certificates" is applied. This can be done for non-internet connected computers by following the procedure below: 1. On a Windows computer connected to the internet, download the latest Certificate Updater (the rootsupd.exe file) from (This requires "Windows Genuine Advantage" verification). Tip: Do not confuse the Windows Genuine Advantage Validation tool (GenuineCheck.exe) for the Certificate Updater (rootsupd.exe) 2. Transfer the Certificate Updater to the non-internet connected computer using a portable media device (such as a USB flash drive or CD). 3. Run the Certificate Updater (there is no progress indicator but you may see the hourglass cursor briefly) Signature verification error Chromeleon installations may fail on non-internet connected computers with Windows operating systems which do not have Microsoft SQL Server installed yet. This failure is caused by specific digital certificates that were generated by Microsoft without proper timestamp attributes. These digital certificates are required to sign some Microsoft core components and software binaries, which could have adverse effects on the ability to correctly install and uninstall Microsoft components and security updates. Page 18
24 Although this signature verification error is reported for 64 bit versions only, the error may also occur on 32 bit platforms. Microsoft recommends that customers install a security update to resolve the problem. The update can be obtained under: After installing the update, reboot the computer. Then proceed with the installation of SQL Server 2008 R Firewall Settings This section describes firewall settings used by Chromeleon. Tip: The (built-in) Windows Firewall is automatically configured during the Chromeleon installation process. However this only can work, if the firewall is enabled during the setup. Therefore make sure that the Windows Firewall is turned ON before you start installing Chromeleon. Chromeleon uses the Net.Tcp Port Sharing Service for communication between Chromeleon software components. The Chromeleon Setup therefore starts this service and changes the Startup type to Automatic. Most Chromeleon software components use TCP Port 1325 (which is registered with IANA for use by Dionex, see Port 1325 is added to the Exceptions list as Chromeleon 7 Services. On Windows Vista and Windows 7 the configuration enables: - incoming localport outbound remoteport 1325 each for both Public and Domain profiles ( Firewall with advanced settings ). Page 19
25 The following software components are also added to the Exceptions list: Chromeleon components: Chromeleon 7 Real Time Kernel (CmDriver.exe) Chromeleon 7 Device Driver Host (CmDDKHost.exe) SQL Server components: SQL Database Service (sqlservr.exe) SQL Browser (sqlbrowser.exe) Note: Chromeleon Setup cannot configure third-party firewalls. These have to be configured manually as described above. Third-party firewalls may also cause problems during the installation process. Therefore make sure that third-party firewalls are turned OFF before you start installing Chromeleon. 3.3 Disabling Power Management This section describes settings that should be made on Chromeleon stations that are directly connected to instruments Disabling Windows Power Management If a computer goes into Standby or Hibernate mode while the Chromeleon 7 Instrument Controller is running, then the USB subsystem will become unavailable. As a result, USB-dependent devices (instruments and the license key) will stop functioning and operation is interrupted. Page 20
26 To disable Windows power management: 1. From the Control Panel open the Power Options. 2. On the Power Schemes tab select Always On. 3. If not already done, change the Standby and Hibernate options to Never Disabling USB Power Management To avoid problems during instrument control, USB specific power saving options must be turned off as well. To disable USB power management: 1. From the Control Panel open System (Properties). 2. Click Device Manager. 3. Expand the Universal Serial Bus Controllers node. On some systems the Universal Serial Bus Controllers node may be called USB Controller. 4. Right-click the USB Root Hub or Generic USB Hub (you might have multiple instances of each) for which you want to change the power savings options, and then click Properties. 5. On the USB Root Hub (or Generic USB Hub) Properties dialog box, click the Power Management tab. 6. Clear the Allow the computer to turn off this device to save power option. 7. Repeat steps 4 to 6 above for all remaining USB instances. Page 21
27 Note: For (third-party) devices controlled by LAN, power management of the LAN card that controls the instrument must be disabled. This is achieved by performing steps similar to those described above. 3.4 Third-Party Software Interference Some kinds of software, for example virus scanners and support assistance tools, can be scheduled to perform tasks when the computer is idle or has a low-level of CPU activity. When configured in this way these types of program can interfere with data collection. It is recommended that programs which can be scheduled to run in this way are either switched off, or set to run manually and used when the computer is not collecting data. Page 22
28 4 Compatibility with Previous Chromeleon and PeakNet Versions 4.1 Software Compatibility Chromeleon 7 and 6 Chromeleon 7 can co-exist with Chromeleon 6 (or PeakNet 6) on the same computer. Chromeleon 7 is installed in a different folder and does not affect the Chromeleon 6 installation. You can even use the Chromeleon 6 and 7 clients at the same time. However, you cannot control instruments using the two software versions at the same time. Caution: You cannot control an instrument using Chromeleon 6 server and Chromeleon 7 Instrument Controller at the same time. When running Chromeleon 6 and 7 on the same computer, an instrument allocated to Chromeleon 6 server is not available to the Chromeleon 7 Instrument Controller (and vice versa). To avoid conflicts between Chromeleon 7 Instrument controller and Chromeleon 6 server, versions, do NOT enable the options to start these services automatically. 4.2 Software Compatibility Chromeleon 7.2 and 7.1 Parallel installation of different Chromeleon 7 versions (or Service Releases) on the same PC is not supported. When Chromeleon 7.2 is installed on a PC where an earlier version of Page 23
29 Chromeleon 7 is present, the earlier version will be upgraded. For more details refer to section Data Compatibility Chromeleon 7 and 6 Chromeleon 7 provides access to Chromeleon 6 data and maintains backward compatibility as much as possible. However, Chromeleon 7 has been designed with focus on future development. In rare scenarios this may result in minor deviations when looking at legacy data in Chromeleon 7. With Chromeleon 7, you can connect to Datasources created with previous Chromeleon 6 / PeakNet 6 versions. You can view the data and you can even do temporary modifications and see the effect on the results. However, you cannot save the changes inside a Chromeleon 6 Datasource. To permanently modify data originating from Chromeleon 6, you must first copy the data from the Chromeleon 6 Datasource to a Chromeleon 7 Data Vault. Note (Oracle datasources only): To access Chromeleon 6 data on a computer that does not have Chromeleon 6 installed you first need to install the Microsoft ODBC driver for Oracle, which is part of the MDAC package. This is the only validated ODBC driver for the connection to Oracle databases (the Oracle-provided driver for ODBC will not work with Chromeleon). You cannot connect to a Chromeleon 7 Data Vault from older Chromeleon / PeakNet versions. Chromeleon 7 cannot read Backup (.cmb) files created with older Chromeleon / PeakNet versions, and it is not possible to export Chromeleon 7 data to any previous Chromeleon version. Page 24
30 It is not possible to import Chromeleon 6 panels to Chromeleon 7, nor the other way around. 4.4 Data Compatibility Chromeleon 7.2 and 7.1 SR2 Chromeleon 7.2 introduces new features that require that the database schema of 7.1 Data Vaults be updated. For example, it adds support for MS instrument control, data visualization and processing, Import/Export options, and Intelligent Run Control functionality. This update may prevent backward compatibility of data created with the Chromeleon 7.2 Client software. Page 25
31 5 Installing the Software 5.1 Do you have Chromeleon 6? If you do not have Chromeleon 6, start installing Chromeleon 7. Follow the steps starting in section 5.2 If you have Chromeleon 6, read section 4 above about compatibility, and decide whether you want to install Chromeleon on the same PC where Chromeleon 6 is running, or on a different one. If you decided to use Chromeleon 7 on the same PC where Chromeleon 6 is running, follow section 5.2. If you decided to install Chromeleon 7 on a different PC, but want to access your Chromeleon 6 data, follow section 5.2, then read section about mounting Chromeleon 6 Datasources. 5.2 Installing Chromeleon 7 Follow the steps below to install Chromeleon 7.2. The steps are basically the same for new installations and for updating existing Chromeleon 6 or Chromeleon 7 installations. Caution: Make sure that the person performing the installation has local administrator privileges in Windows! Otherwise, the installation will fail. If you are asked to do so, do reboot the computer. After the reboot, the administrator who started the setup must log in again so that the installation process can be completed correctly. Page 26
32 Caution: Make sure that third-party firewalls are turned OFF. Note: The (built-in) Windows Firewall service must be running. (Do not confuse with Windows Firewall.) If you need to turn off Windows Firewall for some reason, use the Windows Firewall Control Panel program (Control Panel\System and Security\Windows Firewall), but leave the Windows Firewall service running. Note: Do not connect new instruments/modules via USB to your PC until the Chromeleon software installation is finished and the Chromeleon Installation Qualification (IQ) is completed and passed. Note: Uninstalling previous versions of Chromeleon / PeakNet 6 is not required before installing Chromeleon 7. Note: Setup time varies depending on the presence of thirdparty components. For example, installing.net framework libraries may take considerable amount of time. 1. Check chapter 2 and 3 of this document and verify that all requirements are met. 2. It is best to close all applications before starting the setup to ensure that it can update relevant system files. Note that certain IT tools and anti-virus software may lock system files and therefore require rebooting after the setup. Page 27
33 In addition, installing some of the third-party components (such as Windows Installer and.net Framework) usually require a reboot. 3. Start the Installation: Insert the installation disk into your PC. The Autorun window usually opens automatically. If CD Autorun is not active, or if you install from other media: - Run \Autorun\autorun.exe. This opens the AutoRun window. The AutoRun window offers links for reading this Installation Guide, exploring the installation disk, and launching the installation program. Launch the installation program by clicking Install Chromeleon 7.2, Figure 1. Figure 1: Chromeleon AutoRun window Alternatively, you can run \CmSetup\setup.exe. This starts the installation program directly. Page 28
34 4. The Setup Wizard guides you through the installation procedure; follow the on-screen instructions as they appear. The setup starts with installing the separate "Chromeleon 7 Shared Components" installation package which includes all third-party assemblies. When you install Chromeleon for the first time, a Windows UAC prompt asks you for consent to install the package. After installation of the Shared Components package, the required third-party software components ( section 2.6) are installed, if they are not already present. Installation of SQL Server Express and.net libraries can take 5-20 minutes; installation of Chromeleon files usually takes less than 5 minutes. After that, Chromeleon 7 is installed in one of the following folders: C:\Program Files\Dionex\Chromeleon (32-bit systems) C:\Program Files (x86)\dionex\chromeleon\bin (64-bit systems). The Chromeleon 7.2 setup does not support changing the installation path. Note: Installation of some software components (such as the USB instrument drivers) may trigger a Windows security warning. Please continue the installation if this occurs. Page 29
35 Tip: During the setup several UAC messages are displayed. When not acknowledged, these messages will time-out and the installation will be interrupted. To avoid this it is recommended to not leave the installation unattended. 5. When the License Setup window appears, do one of the following: If a new blue License Key is available and the License File is still stored on the Key: Select the Dongle option, Figure 3A. Insert the License Key into a USB port of the computer Wait a moment until the setup confirms that it found both the Key and the File and transferred the File to the computer. Save a backup copy of the License File by following the Save license file link in the dialog. Click Next, Figure 3B. If a License Key and a License File are both available, but the License File is stored on other media: Select the Dongle option, Figure 3A. Insert the License Key into a USB port of the computer Wait a moment until the setup confirms that it found the Key. Install the license file by following the corresponding link in the dialog. Save the original media with the key as a safety copy. Click Next, Figure 3B. Page 30
36 If either the License Key or the License File is missing, or if the previous procedures failed (for example, due to a mismatch between the key and the file): Click Skip, Figure 3C. You will have to provide a license after the setup has finished, as described in section 5.5. Tip: The Chromeleon Domain Controller option is for networked installations. Contact Thermo Fisher Scientific to learn more about the advantages a networked Chromeleon installation may provide to your laboratory. 6. As the final step, an Installation Qualification Report will be created (see section 5.3). Figure 2: Chromeleon Setup Wizard Page 31
37 A B C Figure 3: License Setup window You can also install Chromeleon using a command line for remote installation. When installing via command line, be aware that the Chromeleon installation consists of two packages the Chromeleon7SharedComponents.msi package and the actual Chromeleon package which have to be installed separately. Note: Make sure to install the Chromeleon7 Shared Components.msi package before starting the actual Chromeleon setup. The Chromeleon7SharedComponents.msi can be started from the Chromeleon7SharedComponents folder which is located in the Chromeleon CmSetup directory. Use the /i switch for installing the package: msiexec / i Chromeleon7SharedComponents.msi. In addition, all standard command line switches allowed for a MSI package may be used. Page 32
38 When upgrading from a version earlier than Chromeleon 7.1 SR1 via command line, you have to uninstall the previous Chromeleon installation first. To ensure that all Chromeleon program files are removed, it is recommended to use the Chromeleon Uninstaller program located in the following folder of the Chromeleon DVD: CmSetup\Chromeleon71Uninstaller\ChromeleonUninstaller.exe. Caution: Do NOT run the Chromeleon 7.2 setup, if the Chromeleon program files are not removed completely! 5.3 Installing Software for Controlling Specific Third-Party Instruments For controlling certain third-party instruments it is necessary to manually install additional software from the instrument vendor following the Chromeleon installation: Agilent Instrument Control Framework (ICF) and LC Driver Package This software must be installed for controlling Agilent liquid chromatographs from Chromeleon (it is NOT required for controlling Agilent GCs). Rheodyne MXII Series Valves Driver This software is necessary to communicate with Rheodyne MXII Series Valves over USB. Waters Acquity UPLC System Instrument Driver This software must be installed for controlling Waters Acquity UPLC system modules. Page 33
39 Chromeleon 7 The Drivers folder of the Chromeleon installation disk contains the driver versions that were tested and were current at the time of releasing Chromeleon 7.2. Please refer to section 2.7 for further details. 5.4 Installation Qualification At the end of the installation process, Chromeleon automatically runs an Installation Qualification (IQ), and creates a report. You can view the report by selecting the Show the IQ report after closing the wizard check box (enabled by default) on the last page of the Setup wizard, Figure 4A. Figure 4: Last page of the Setup Wizard Page 34
40 Tip: To read the report later, click Start > All Programs > Chromeleon 7 > Station IQ > Current IQ report. The log file opens in your default web browser. Note: Your browser may display a security warning about active content (scripts / ActiveX controls) in the report. This is caused by scripts in the IQ that can allow you to expand and collapse the different sections of the report for your convenience and better overview. These scripts can be safely run, but are not mandatory; all content can be read without enabling the scripts. The IQ compares current information about the installed files against a reference list supplied by Thermo Fisher Scientific. If there are any differences, a Warning, or an Error message appears to indicate the following: Warning: A Warning can indicate an obvious problem that can be easily corrected; for example, by providing a valid license file, installing more RAM in the PC, or starting Windows services. A Warning can also indicate that a file does not have the expected time stamp or version. Usually, no action is required for minor file discrepancies. If a problem occurs nevertheless, try to repair the installation as described in section If the problem persists, follow the other steps described in section 5.6 to troubleshoot the installation. Error: A vital component is missing or corrupt. Try to repair the installation (see section 5.6.1). If this does not help, follow the other steps provided in section 5.6 for troubleshooting. Page 35
41 Note: After the initial installation of Chromeleon 7, the IQ report may contain a warning about a missing license, as it will if you clicked Skip in the License Setup dialog during the software installation (section 5.2, Figure 3C). Follow the steps in section 5.5 to provide a valid license. Tip: You can run the IQ at any time to check if your installation is intact. To start the IQ, click Start > All Programs > Chromeleon 7 > Station IQ > Station IQ. For more information, press F1 in the Chromeleon IQ window. Tip: All IQ Reports (and also the installation log files) can be easily accessed by clicking Start > All Programs > Chromeleon 7 > Station IQ > All IQ Reports. The physical location of the files is a (normally hidden) directory whose location depends on the operating system: Windows XP: C:\Documents and Settings\All Users\ Application Data\ Dionex\Chromeleon\IQ Windows Vista / Windows 7: C:\ProgramData\Dionex\Chromeleon\IQ 5.5 Activating / Updating a License The license is normally activated already during the software installation process, as described in section 5.2. This chapter describes how to: Activate a license when the License Setup step was skipped during the software installation (Figure 3C) Update the license for an existing installation (for example after purchasing new licensed features for an existing installation) Page 36
42 The processes are similar, but there is a difference depending on where the License File is located: if a new light blue License Key containing the License File is used, follow Section if a License File is available on separate media, follow Section Using a New Chromeleon 7 License Key that Contains a License File Follow the steps below to activate or update a Chromeleon 7 station using a light blue License Key that has never been used before and thus it still contains the corresponding License File. 1. Make sure that Chromeleon 7 is already installed. 2. Connect the License Key to a USB port of the PC where the license will be used. The Windows Found New Hardware wizard may start at this point and install the necessary drivers. 3. After a few seconds, the License File is automatically (without a warning) moved to the computer, in the appropriate location. 4. To check the installed licenses, start the Administration Console: Start > All Programs > Chromeleon 7 > Administration Console. Select the License Overview node, Figure 5A. The Total column should display the appropriate number of licensed options, Figure 5B. Page 37
43 Figure 5: The License Overview node (A) of the Administration Console shows the available licenses in the Total column (B). 5. Back up your License File and store it in a safe location. You may need it in the future, for example if you want to move the license to another computer, or when restoring your Chromeleon station after a hard disk failure. Section describes the location where you can find the License File that was moved from the License Key to the computer Using an Empty License Key and a Separate License File Follow the steps below to: Activate a Chromeleon 7 station using a Chromeleon 6 (green) License Key, or Activate a Chromeleon 7 station using a Chromeleon 7 (light blue) License Key that has been used before, or Page 38
44 Modify licensing for a Chromeleon 7 station, for example when a new License File has been received after an upgrade, or when moving a license to another computer. Note: Make sure you have the License File that you want to use. The serial number of the License File must match the serial number of the License Key. 1. Connect the License Key to a USB port of the PC (Chromeleon 7 must be installed first). The Windows Found New Hardware wizard may start at this point and install the necessary drivers. 2. Open the Administration Console by clicking Start > All Programs > Chromeleon 7 > Administration Console, and select the License Manager node, Figure 6A. 3. Click the Update License File link (Figure 6B) and browse to the License File you want to use. Select the file and click Open. The License File is copied to its desired location (see section 2.1.2). Figure 6: License Details Page 39
45 4. To check the installed licenses, select the License Overview node, Figure 5A. The Total column should display the appropriate number of licensed options (Figure 5B). 5. Store your License File in a safe location. You may need it in the future, for example if you want to move the license to another computer, or when restoring your Chromeleon station after a hard disk failure. 5.6 Troubleshooting Software Installation The setup process itself checks for various conditions and provides useful hints/warnings for preventing installation issues. Therefore always observe the instructions during setup. For example the setup checks whether: the user who started the setup has local administrator privileges, the computer has enough RAM and hard disk capacity, the Operating System requirements are fulfilled. Make sure that all requirements and Windows configuration steps described in chapters 2 and 3 are fulfilled / performed. To identify installation issues, check the IQ Report (see section 5.3) for Errors and Warnings. If you find Errors, try to repair the installation as described in section (Remember, that you can re-run the IQ at any time.) Problems with third-party software components can often be resolved by reinstalling the component manually as described in section Reading section in advance will help you understand the details of the installation process. If you still face installation problems, send the installation log files to the Thermo Fisher Scientific Service for Dionex Page 40
46 Chromatography Software for support. All the installation log files are located in a single folder (together with the Station IQ Reports) that can be easily accessed via the Start menu: Start > All Programs > Chromeleon 7 > Station IQ > All IQ Reports. Some of the log files are large (~25 MB), but they can be compressed (zipped) efficiently Errors which Stop Installation If any critical errors are encountered during installation a dialog box will be shown describing the error. You can get more details about the error by clicking on the Details >> button. Review the error details and fix any issues listed before restarting the installation process. Tip: If you encounter the Error message: "Setup has detected that the file <path> has either changed since it was initially published or may be corrupt." Empty the C:\Users\(username)\AppData\Local\Temp folder and re-start the installation. In some cases this action will not resolve the error. In this instance you will need to log onto Windows as a different user to perform the installation Repairing an Installation Follow the instructions below to repair a Chromeleon 7 installation: Note: You will need access to the Chromeleon installation media to repair an installation. Page 41
47 1. Choose Start > Control Panel > Add or Remove Programs (Windows XP) or Programs and Features (Windows Vista / Windows 7). 2. Select Dionex Chromeleon 7, click Change (Windows XP) or right-click and select Repair (Windows Vista / Windows 7). Caution: Be careful to click just once, because in Windows Vista and Windows 7, double-clicking an item will initiate removal (and not repair!) of the item. 3. Follow the Wizard to repair the installation Installation Process Details Understanding the installation process makes it easier to troubleshoot installation issues. The setup takes place in several stages: From the splash screen (Autorun\Autorun.exe) the main setup (CmSetup\setup.exe) is called. If not already present, this installs the following third-party software components: Windows Installer (stand alone setup is available) Microsoft.NET Framework (stand alone setup is available) Microsoft SQL Server Express (stand alone setup is available) Chromeleon 7 Shared Components (stand alone setup is available) Note: The installation process cannot be completed unless the above components are successfully installed. Page 42
48 After that, it calls CmSetup\CM\CmSetup.msi, which in turn installs the following components: Microsoft Visual C++ Redistributable (embedded into the Chromeleon 7 setup) MSXML (embedded into the Chromeleon 7 setup) WibuKey Software (stand alone setup is available) Amyuni PDF Converter (stand alone setup is available) Chromeleon Manual Installation of Third-Party Software Components Chromeleon 7.2 uses certain third-party software components. If not already present, these are installed automatically during the installation process. If you experience problems with any of the required third-party software components, you can try reinstalling them manually from the Chromeleon 7 installation disk as described in the sections below Windows Installer Chromeleon 7.2 requires Windows Installer version 4.5 or higher for the setup. The required Windows Installer version is nowadays present on nearly all PCs, as it is either part of the supported Windows version (for example Windows 7 contains Windows Installer 5.0) or has been rolled out as part of Windows Update (e.g. KB942288, KB958655). If the required Windows Installer version is not present, it is installed before the actual Chromeleon 7 installation starts. After installing Windows Installer, a reboot is required. Page 43
49 If you experience serious problems during the setup, you may try to reinstall Windows Installer from the Chromeleon 7 installation disk by running the appropriate installer from the \CmSetup\WindowsInstaller4_5\ folder Microsoft.NET Framework Chromeleon 7.2 requires Microsoft.NET Framework 3.5 SP1 and 4.0. Various.NET versions are often installed on PCs nowadays. If the required.net version is not already present, the necessary files are installed before the actual Chromeleon 7 installation starts. After installing.net, a reboot may be required. The Chromeleon Installation Qualification (IQ) reports the installed.net version(s). If you suspect problems with the.net installation, you can try to install/repair it by running \CmSetup\DotNetFX35SP1\ dotnetfx35setup.exe (for.net version 3.5) or \CmSetup\DotNetFX40\dotNetFx40_Full_x86_x64.exe (for.net version 4.0) from the Chromeleon 7 installation disk Chromeleon 7 Shared Components Chromeleon 7.2 requires: Sycnfusion version Log4Net version These installations are installed during the Chromeleon 7 Shared Components setup (which runs as part of the Chromeleon 7 installation. To re-install these components, re-run CmSetup\Chromeleon7SharedComponents\ Chromeleon7SharedComponents.msi (or the entire setup CmSetup\setup.exe). The installation events are logged (together with other installation and qualification log files) in the IQ folder (see section 5.4) Page 44
50 Note: The software included in Chromeleon 7 Shared Components (Sycnfusion and Log4Net) cannot be installed individually from the Chromeleon installation media Microsoft SQL Server Express Edition Chromeleon 7.2 uses Microsoft SQL Server Express Edition as the database engine for Standard (local) Data Vaults. If no SQL Server Express is present, SQL Server 2008 R2 Express Edition SP2 is installed automatically during the Chromeleon setup, including the necessary server and client components and the corresponding Software Development Kit (SDK). This takes place before the actual Chromeleon 7 installation starts. If an SQL Server version earlier than 2008 R2 Express is already present, the SQL Server will NOT be updated automatically. The Chromeleon Installation Qualification (see section 5.3) reports the installed SQL Server version. The IQReport will contain a Warning if a version higher than SQL Server 2008 R2 Express SP2 was found. If the IQ reports any problems with SQL Server Express, advanced users may try to manually update/reinstall it from the Chromeleon 7 installation disk under \CmSetup\SQL 2008 R2 SP2 Express and then run: SQLEXPR_x64_ENU.EXE (64 bit) Windows SQLEXPR32_x86_ENU.EXE (32 bit PC) Caution: Manual installation of SQL Server requires advanced database administrator knowledge. Page 45
51 Caution: Installing SQL Server 2008 R2 Express SP2 may affect other software using SQL Server Express on the same computer! The installation events are logged in the following location: C:\Program Files\Microsoft SQL Server\100\Setup Bootstrap\LOG\. To understand the details in the log files, refer to the Microsoft article "How to: View and Read SQL Server Setup Log Files" at Microsoft Visual C++ Redistributable Chromeleon 7.2 requires the following versions of Microsoft Visual C++ Redistributable: Version 2005 SP1, 2008 SP1 and These installations are embedded (as recommended by Microsoft) into the Chromeleon 7 setup. To re-install these components, re-run CmSetup\CM\CmSetup.msi (or re-run the entire setup CmSetup\setup.exe). The installation events are logged (together with other installation and qualification log files) in the IQ folder (see section 5.4) Microsoft MSXML Chromeleon 7.2 requires Microsoft MSXML version 4 SP2. This installation is embedded (as recommended by Microsoft) into the Chromeleon 7 setup. To re-install this component, rerun CmSetup\CM\CmSetup.msi (or re-run the entire setup CmSetup\setup.exe). The installation events are logged (together with other installation and qualification log files) in the IQ folder (see section 5.4). Page 46
52 WibuKey Software Chromeleon 7.2 uses the WibuKey software version 6.11 as part of the software licensing infrastructure. The necessary files are automatically installed during the installation process. After the Chromeleon installation is complete, the CM IQ checks whether the WibuKey Software is properly installed. If it is not, an Error is issued. If you experience problems with licensing, you may try to reinstall the WibuKey software from the Chromeleon 7 installation disk by running \CmSetup\WibuKey Runtime\WkRuntime.exe. There is no installation log available for the WibuKey software setup Amyuni PDF Converter Chromeleon 7.2 uses the Amyuni PDF Converter version for exporting results in PDF format. The necessary files are automatically installed during the installation process. After the Chromeleon installation is complete, the CM IQ checks whether the Amyuni PDF Converter is properly installed. If, for some reason, the Amyuni PDF Converter could not be installed, an Error is issued. In this case, the installation events are logged in a file called PDFInstall.log. The log file is stored (together with other installation and qualification log files) in the IQ folder (see section 5.4). Page 47
53 6 Installing Thermo Scientific Dionex Instruments This section describes how to install chromatography instruments that are connected via USB to the PC. Chromeleon can control chromatography instruments from other manufacturers. (The List of Supported Instruments in the Documents folder of the installation disk provides an overview). Setup and requirements differ for each module. The Instrument Configuration Manager Help provides information about which modules are supported and how to install them. Caution: Do not connect new instruments/modules via USB to your PC until the Chromeleon software installation is finished and Chromeleon Installation Qualification (IQ) is completed and passed. To set up a system connected via USB: 1. Connect all modules to each other and to the PC according to the Operating Instructions of the modules and section Load the USB drivers for the module(s) according to section Add your chromatography instrument(s) to the system configuration using the Instrument Configuration Manager according to section Connecting Modules via USB Most Thermo Scientific Dionex instruments are connected to the PC or to each other via USB. Some of them (such as detectors Page 48
54 that acquire data at high rates) require USB 2.0 connections. Others can be connected to USB 1.1 connections as well. Some Dionex instruments have a built-in USB hub. The hub may be USB 2.0 or 1.1; it may be powered or unpowered. The following guidelines must be observed when connecting modules via USB: Modules with USB 2.0 connection must be connected directly to the PC (recommended for detectors) or to another module with a USB 2.0 hub. Modules with USB 1.1 connection can be connected directly to the PC or to another module with any kind of USB hub. A powered hub continues to function when the module is switched off, maintaining communications for devices connected to the hub. An unpowered hub only maintains connections while the device is switched on. The List of Supported Instruments (see Documents folder of the installation disk) specifies what kind of USB connection an instrument requires (and provides, if it has a hub). 6.2 Loading the USB Driver for a Module 1. Turn on the computer first, but not the module. 2. Under the Windows operating system, log on using an account with local administrator privileges: 3. Turn on the module using the main power switch. 4. Windows Vista / Windows 7 automatically detects the new module and performs the USB installation. Page 49
55 Windows XP automatically detects the new module and launches the Found New Hardware Wizard, which guides you through the USB installation. Select the following options: a) If asked whether Windows may connect to Windows Update to search for software, select No, not this time. b) Accept the default option (Install the software automatically) and click Next>. c) Click Finish when the wizard reports that the software for the module has been installed. 6.3 Troubleshooting USB Issues Problem Windows Vista / Windows 7 fails to detect the module and launches a wizard instead Remedial Action This indicates that you connected the module to the computer and turned on the power for the first time before you installed Chromeleon. To resolve the problem: 1. Click Cancel to exit the wizard. 2. Turn off the module and unplug the USB cable from the computer. 3. Install Chromeleon. 4. Reconnect the USB cable to the computer and turn on the power to the module. Windows Vista will now detect the module and install the USB software for the module automatically. Page 50
56 Problem Windows XP fails to detect the module and a message box asks for a USB configuration file (CmWdmUsb.inf) Remedial Action This indicates that you connected the module to the computer and turned on the power for the first time before you installed Chromeleon. To resolve the problem: 5. Click Cancel in the Windows message box. 6. Turn off the module and unplug the USB cable from the computer. 7. Install Chromeleon. 8. Reconnect the USB cable to the computer and turn on the power to the module. Windows will now automatically detect the module and launch the Found New Hardware Wizard. Page 51
57 Problem Chromeleon Audit Trails include error messages that indicate interruption of USB communications, such as: "Error receiving status: Error reading from <device USB <address>. The I/O operation has been aborted because of either a thread exit or an application request. The license is invalid." Windows Application and System Event Logs may include error messages related to: - Chromeleon - The disk I/O system - W32time - And other functions Remedial Action This indicates that the Instrument Controller PC entered Standby or Hibernate mode while Chromeleon was operating instruments / collected data. Follow sections and to disable (USB) power management. Page 52
58 7 Configuring Chromeleon 7 This chapter describes configuration steps that are likely to be performed for most stand-alone Chromeleon installations. Note: You need Windows (local) administrator privileges and/or the appropriate Chromeleon privileges to perform most of the tasks described in this chapter. Note: The paths mentioned in this chapter contain folders that are hidden by default. If you do not see them, follow instructions in Windows Help on how to display hidden files and folders. Starting Points for Configuring Chromeleon 7 You can start all configuration work for Chromeleon 7.2 from two starting points: from the Chromeleon Services Manager, which is a Chromeleon tool that appears minimized as the Chromeleon Tray Icon in the Notification Area of the Windows Taskbar, and from the Administration Console, which is a Chromeleon tool that can be started via the Start menu Chromeleon Services Manager The Chromeleon Services Manager (the window in the top half of Figure 7): Page 53
59 Chromeleon 7 shows the overall status of Chromeleon s service components (Figure 7B), and provides a starting point for instrument control related configuration work (Figure 7C,D,E). Tip: You can read more about the Chromeleon services in the Glossary. Figure 7: Chromeleon Services Manager and Tray Icon The Services Manager is usually started automatically, and it appears minimized as the Chromeleon Tray Icon (Figure 7A) next to the clock in the Notification Area (also called System Tray ) of the Windows Taskbar. To open the Services Manager window, click (or right-click) the Chromeleon Tray Icon, Figure 7A. Page 54
60 If the Chromeleon Tray Icon is not present, you can start the Services Manager by selecting Start > All Programs > Chromeleon 7 > Services Manager. Closing the Services Manager window minimizes it again to the Chromeleon Tray Icon Chromeleon Tray Icon The Chromeleon Tray Icon (Figure 7A) appears next to the clock in the Notification Area (also called System Tray) of the Windows Taskbar. It is the minimized version of the Services Manager. It has the following functionality: It provides an easy way to open the Services Manager window (via a click or a right-click on the Tray Icon). The Tray Icon and its tool tip (Figure 7F) show the status of the Instrument Controller Service. Its context menu provides a shortcut for starting/stopping the Instrument Controller Service (Figure 7C ) and launching the Instrument Configuration Manager (Figure 7D ). If the Chromeleon Tray Icon is not present in the Notification Area, start it by clicking Start > All Programs > Chromeleon 7 > Services Manager. Page 55
61 7.1.3 Chromeleon Administration Console The Chromeleon Administration Console (Figure 8) provides the starting point for most administrative tasks in Chromeleon, such as: managing licenses scheduling data transfer between Data Vaults, for example for archiving purposes managing Chromeleon Users, Groups and Privileges configuring Global Policies, for example enabling User Mode monitoring Discovery that is checking which resources (Instruments and Data Vaults) are available in a Chromeleon Domain managing Data Vaults installed on the Local Machine Tip: Some of these features are only available in a networked installation and are therefore not covered in this document. Contact your local Thermo Fisher Scientific sales organization for Dionex Chromatography software to learn more about the advantages a networked Chromeleon installation may bring to your laboratory. Page 56
62 Figure 8: Chromeleon Administration Console with (A) various nodes in the navigation area on the left, and (B) work area on the right To open the Chromeleon Administration Console select Start > All Programs > Chromeleon 7 > Administration Console. 7.2 Configuring Instruments / Modules After the USB software for the module has been installed (see section 6.1), install and configure the module in Chromeleon: 1. Start the Instrument Controller Service either by rightclicking the Chromeleon Tray Icon (Figure 7A) and choosing Start Chromeleon Instrument Controller (Figure 7C ), or from the Services Manager (Figure 7C). The Chromeleon Tray Icon changes to indicate that the Instrument Controller Service is starting. Wait until the Instrument Controller Service is running idle. If the Chromeleon Tray Icon is not on the Taskbar, click Start > All Programs > Chromeleon 7 > Services Manager to open the Services Manager and click Start Instrument Controller. Page 57
63 2. Start the Chromeleon Instrument Configuration Manager: Choose Configure Instruments either after right-clicking the Chromeleon Tray Icon (Figure 7D ) or in the Services Manager (Figure 7D). (If the Services Manager window is open, you can now close it. Note that closing the Services Manager does not stop the Instrument Controller Service.) 3. If necessary, click the plus sign next to the PC s name to display the items underneath (Figure 9A). 4. Select the Instrument to which the module will be assigned, or create a new Instrument. To create a new instrument, on the Edit menu, click Add Instrument, or click the corresponding icon in the Toolbar, Figure 9B. 5. Click Add Module on the Edit menu, or click the corresponding icon in the Toolbar, Figure 9C. 6. On the Manufacturers list (Figure 9D), click Thermo Scientific and on the Modules list (Figure 9E), click the module. 7. Chromeleon connects to the module, transfers the settings from the module to Chromeleon, and automatically sets the options on the configuration dialog pages (Figure 9F) accordingly. Confirm the related message with OK. Tip: Most modules are connected via a USB interface. The USB address is then used by Chromeleon to detect a module. The USB address typically contains the serial number of the module, allowing you to distinguish between modules Page 58
64 when two or more identical modules are present (such as two pumps of the same model). Click Browse and double-click on the USB number. Only the USB addresses of corresponding modules are shown; for example, when adding a UV detector only the address(es) of the UV detector(s) are shown. 8. On each configuration page, verify that the settings are correct and define additional settings if needed. For assistance, press F1. 9. On the File menu, click Save Instrument Configuration, or click the corresponding icon in the Toolbar, Figure 9G. Close the Instrument Configuration Manager. Figure 9: Using the Instrument Configuration Manager Page 59
65 7.3 Enabling Automatic Start of the Instrument Controller Service On PCs that are physically connected to instruments (Chromeleon Workstations and Instrument Controller Stations ), especially if they are controlled remotely from another PC with Chromeleon (a Remote Client station), Thermo Fisher Scientific recommends starting the Instrument Controller Service every time the computer is started. Tip: If the PC is not connected physically to instruments (Chromeleon Data Client and Remote Client stations), you should not follow these steps, which would result in using additional PC resources unnecessarily. To enable automatic start of the Instrument Controller Service 1. Open the Services Manager by clicking the Chromeleon Tray Icon (in the Notification Area of the taskbar), or by clicking: Start > All Programs > Chromeleon 7 > Services Manager. 2. Select the Start service at system start check box, Figure 7E. 3. To start the service this time, click the Start Instrument Controller button in the Services Manager, Figure 7C. 4. Close the Services Manager. Page 60
66 7.4 Configuring Data Vaults Tip: The Chromeleon Client Online Help contains a chapter about Backing Up Chromeleon Data, see Chromeleon 7 Help > Administrating Chromeleon Default Data Vault, XVault, and Default Location During the software installation, a Standard Data Vault called ChromeleonLocal is automatically generated (in the corresponding sub-folder) in the default location (see below). During the installation another local Data Vault (an XVault ) will be created. This is a special Data Vault that stores a cached copy of the running Sequence. The purpose of the XVault is to keep instruments running and data accessible for processing during network outages, but it is an essential part of stand-alone installations as well. The XVault is hidden. Tip: The default Standard Data Vault and the XVault needs no configuration. The default location for Standard Data Vaults is: Windows XP C:\Documents and Settings\All Users\Application Data\ Dionex\Chromeleon\DataVaults\<data vault name> Windows Vista / Windows 7 C:\ProgramData\Dionex\Chromeleon\DataVaults\<data vault name> Page 61
67 7.4.2 The Data Vault Manager The Data Vault Manager is a Chromeleon tool that helps you with the following tasks: Creating a new Data Vault (see section 7.4.3) You may want to create a new Data Vault if, for example: You want to have Data Vaults with and without Data Audit Trails / versioning, You want to separate data at a high level (note that you can also separate data in various folders inside the same Data Vault, and you can specify different access rights/privileges for different folders), You want to move (archive) some data from your live Data Vault to save space there. Note: The database part of a Standard Data Vault has a 10 GB size limit. (The database holds sample information, the methods, and the Audit Trails, but not the raw data). Tip: Do not create too many Data Vaults. Running Queries (searching for data) is more efficient if the data is not scattered across many different Data Vaults, because Queries can only work in one Data Vault at a time. Mounting a Chromeleon 6 Datasource (see section 7.4.4) You may want to mount Chromeleon 6 Datasources (read-only!) that exist locally or on the network. Page 62
68 Dismounting / Mounting a Chromeleon 7 Data Vault The Discovery Service finds Chromeleon 7 Data Vaults in the network automatically. Manual dismounting / mounting is only necessary for advanced administrative tasks like moving or renaming a Data Vault. These are not covered in this document. To start the Data Vault Manager: 1. Open the Administration Console, click the Local Machine node in the navigation area (Figure 10A) then click Manage Data Vaults in the work area (Figure 10B). 2. Alternatively, click Start > All Programs > Chromeleon 7 > Data Vault Manager. 3. The Data Vault Manager opens in a separate window (Figure 10C). Figure 10: Starting the Data Vault Manager Page 63
69 7.4.3 Creating a Standard Data Vault 1. Start the Data Vault Manager as described above. 2. In the Data Vault Manager window, click Create, Figure 10D 3. Choose the Create standard data vault option in the Wizard that opens, Figure 11A. Click Next. 4. Enter a name for the new Data Vault, Figure 11B. Click Finish A B C Figure 11: Creating a Standard Data Vault Page 64
70 Note: Thermo Fisher Scientific recommends keeping the default path (Figure 11C). This has the following advantages: a) Ensures automatic protection of the Data Vault via standard Windows user rights. b) Allows easy backup of all your data from a single location (see Chromeleon 7 Help > Administrating Chromeleon > Backing Up Data). If you create the Data Vault in another location, such as on another hard drive, you must take care of protecting the Data Vault by configuring Windows user rights like this: Deny access for ordinary users, Grant access for SQL Server and LocalSystem accounts Mounting Chromeleon 6 Datasources If you install Chromeleon 7 on a PC where CM 6 is already installed, your mounted Chromeleon 6 Datasources will automatically become available (read only) in Chromeleon 7. For connecting other Chromeleon 6 Datasources, follow the steps below. To mount a Chromeleon 6 Datasource: 1. Start the Data Vault Manager as described in section In the Data Vault Manager, click Chromeleon 6, (Figure 10E) Note: When you try to access a Chromeleon 6 Datasource where access control is enabled, you have to provide a valid Chromeleon 6 user ID and password. Page 65
71 3. Click Browse (Figure 12A) or Datasource manager (Figure 12B) in the dialog that opens 4. Follow familiar Chromeleon 6 steps A B Figure 12: Initial steps for mounting Chromeleon 6 Datasources Note: Chromeleon 7 actually utilizes the same Registry keys for storing Datasource connection data as Chromeleon 6 does. For Common Datasources: HKEY_LOCAL_MACHINE\Software\Dionex\Chromeleon\Datas ources\... For not common Datasources: HKEY_CURRENT_USER\Software\Dionex\Chromeleon\Dataso urces\... Consequently, when Chromeleon 6 is installed on the same PC, changes in Chromeleon 7 and Chromeleon 6 mutually affect each other. Page 66
72 7.5 Enabling and Configuring User Management When User Mode is enabled, a logon is required to open Chromeleon. In addition, you can configure which resources (such as data and instruments) certain users are allowed to work with (Access Groups), and what they are allowed to do (Roles). Two basic steps are necessary to start working with User Mode: 1. Enable User Mode. In the Administration Console ( section 7.1.3), select the Global Policies node (Figure 13A). On the Security tab, select the User mode enabled option (Figure 13B). Click Save Changes (Figure 13C). In the confirmation dialog, enter the credentials of a Chromeleon user that has the privilege to Manage Global Policies (Figure 13D). For the default credentials, see the Note below. 2. Configure User Mode In the Administration Console expand the User Database node and use the sub-nodes to configure User Management (Figure 14A). Page 67
73 Figure 13: Enabling User Mode Figure 14: The Chromeleon Administration Console provides the nodes for configuring User Management Page 68
74 Note: The default User Name and Password are cmadmin and admin, respectively. You should not delete the cmadmin User and you should keep the Full Access role assigned to it. You should change the password, write it down and store it at a safe location. You can then use this account for emergency situations, such as when ordinary administrators forget their passwords or lock themselves out from certain areas. Figure 14 shows a typical window for configuring Roles. Tip: To learn more about how to create user accounts, define Access Groups and Roles, please refer to the Administrating Chromeleon > User Management chapter in the Chromeleon 7 Help. You can also access context sensitive Help pages by pressing F1 when working with the Administration Console. Tip: There is an example user database on the installation disk: \Contributed Content\User Management Templates. The user database is an encrypted XML file (UserDb.EXML). It is stored in the following location (neither the location nor the file name can be changed): Windows XP C:\Documents and Settings\All Users\ Application Data\ Dionex\Chromeleon\ Windows Vista / Windows 7 C:\ProgramData\Dionex\Chromeleon\ Page 69
75 7.6 Licensing The license is normally activated already during the software installation process, as described in section 5.2. Section 5.5 describes how to Activate a license when the License Setup step was skipped during the software installation Update the license for an existing installation (for example after purchasing new licensed features for an existing installation) Page 70
76 8 Removing Chromeleon 7 from a PC Removing Chromeleon from your computer consists of the following stages: Uninstalling Chromeleon 7 Uninstall Chromeleon7 Shared Components Uninstalling third-party software Removing Chromeleon 7 data Note: You must log on with local administrator privileges to Windows to perform some of the steps in this chapter. Note: The paths mentioned in this chapter contain folders that are hidden by default. If you do not see them, follow instructions in Windows Help on how to display hidden files and folders. 8.1 Uninstalling Chromeleon 7 You can remove the Chromeleon program files from your computer by following the instructions below. Tip: These steps only remove the software components. All your data and settings will be preserved. This has the advantage that you can safely uninstall the software without affecting your data for example, to fix a broken installation. Page 71
77 1. In the Windows Control Panel, click Add or Remove Programs. (Windows XP) or Programs and Features (Windows Vista / Windows 7). 2. Select Chromeleon7 Shared Components from the list of currently installed programs and click Remove (Windows XP) or right-click and select Uninstall (Windows Vista / Windows 7). 3. Select Dionex Chromeleon 7.2 from the list of currently installed programs and click Remove (Windows XP) or rightclick and select Uninstall (Windows Vista / Windows 7). 4. Follow the on-screen instructions to remove Chromeleon If the wizard asks so, reboot your computer. 8.2 Uninstalling Third-Party Software Chromeleon relies on several third-party software components (see section 2.6), which are installed during the setup process (see section 5.6.3). However, to avoid problems with software installed after Chromeleon, most of them are not removed automatically when uninstalling Chromeleon 7. You can remove most of these software components manually following steps similar to removing Chromeleon 7 (see section 8.1). Caution: The software components listed below may be used by various applications on your computer, not only Chromeleon 7. Removing them may corrupt those applications! Page 72
78 The following components will not be removed by the Chromeleon 7 uninstall process: Windows Installer Microsoft.NET Framework Microsoft SQL Server Express WibuKey Software Amyuni PDF Converter The uninstall process will attempt to remove the following components: Microsoft Visual C++ Redistributable MSXML Redistributable These will be removed if Windows determines that they were only used by Chromeleon Removing Chromeleon 7 Data Caution: The following steps will delete all locally stored Chromeleon data (including chromatograms, custom epanels, Instrument Configuration, User Database, etc) from the PC! If you want to save the data, follow the steps in section Administrating Chromeleon > Backing Up Data of the Chromeleon 7 Help before you continue. Page 73
79 Reboot the computer (or stop the SQL Server (SQLEXPRESS) service), then delete the following folder: Windows XP C:\Documents and Settings\All Users\Application Data\ Dionex\Chromeleon\ Windows Vista / Windows 7 C:\ProgramData\Dionex\Chromeleon Note: If you created local Data Vaults in locations other than the default path, you will have to delete these separately. Page 74
80 Index.NET Framework 13, 44 Administration Console 58 Administrator Privilege 26, 51, 55, 74 Agilent Instrument Control Framework 15 Amyuni PDF Converter 14, 48 Automatic Service Start 62 Backup 64, 69 Chromeleon Administration Console 58 Data Vault Manager 65 Installation Qualification 33 Instrument Configuration Manager 59 Services Manager 55, 59 Tray Icon 57 User Manager 70 Chromeleon 6 Compatibility with ~ 22 Installing Chromeleon 7 in Presence of ~ 25 Mounting Datasource 69 Compatibility Chromeleon 6 Data 23 Chromeleon 6 Software 22 Chromeleon 7 Data 24 Chromeleon 7 Software 22, 24 PeakNet 6 Data 23 PeakNet 6 Software 22 Data Vault 64 Creating 68 Data Vault Manager 65 Database Support 11 Datasource Mounting 69 Default Data Vault 64 Documentation Conventions 1 Overview 2 Dongle 3, 5 Firewall Settings 18 Firmware Requirements 5 Found New Hardware Wizard 52 Hardware Installation 50 Hardware Requirements 6 ICF (Agilent) 15 Installation Configuration 59 Hardware 50 Software 25 USB Modules 50, 51 Installation Path 29 Installation Qualification (IQ) 33 Instrument Configuration Manager 59 Instrument Controller Service 62 Instruments Supported 5 Key Code 5 LC Driver Package (Agilent) 15 License Activation 36 License File 4, 5 License Key 3, 5 License Update 36 Page 75
81 Licensing Requirements 3 Microsoft Visual C++ 14 Microsoft Visual C++ 47 Modules Supported 5 Mounting Chromeleon 6 Datasource 69 MSXML 14, 48 Operating System Requirements 8 PC Requirements 6 PDF Converter 14, 48 PeakNet 6 Compatibility 22 Power Management USB 20 Windows 20 Removing Chromeleon 7 Data 76 Chromeleon 7 Software 74 Third-party Software 75 Requirements 3 Database 11 Firmware 5 License 3 Operating System 8 PC Hardware 6 Third-Party Software 12 Third-Party Software for Instrument Control 14 Rheodyne MXII Series Valves 15 Security Updates 9 Services Manager 55, 59 Software Installation 25 SQL Server Express 11, 13, 46 Supported Instruments 5 Supported Modules 5 System Requirements 3 Third-Party Software For Instrument Control14, 33 Installing 44 Requirements 12 Third-Party Software for Instrument Control 33 Tray Icon 57 Troubleshooting Hardware Installation 52 Software Installation 41 Uninstall Chromeleon / PeakNet 6 Software 26 Chromeleon 7 Software 74 Third-party Software 75 USB Installation 50, 51 USB Power Management 20 User Manager 70 User Mode 70 Visual C++ 14 Visual C++ 47 Waters Acquity 16 WibuKey Software 48 WIBU-KEY Software 14 Windows Security Updates 9 Service Packs 8 Windows 7 8 Windows Vista 8 Windows XP 8 Windows Installer 12, 44 XVault 64 Page 76
82 Australia Austria Belgium Brazil China Denmark France Germany India Italy Japan Korea Netherlands Singapore Sweden Switzerland Taiwan UK/Ireland USA and Canada
Installation Guide Chromeleon 7
Chromeleon 7 for Stand-alone Installation Thermo Scientific Dionex Chromeleon Software Version 7.1 SR2 September 2012 Doc. No. 7829.0003, Rev. 2.2 Table of Contents Table of Contents 1 About the Documentation
Installation Instructions Release Version 15.0 January 30 th, 2011
Release Version 15.0 January 30 th, 2011 ARGUS Software: ARGUS Valuation - DCF The contents of this document are considered proprietary by ARGUS Software, the information enclosed and any portion thereof
UNICORN 6.4. Administration and Technical Manual
UNICORN 6.4 Administration and Technical Manual Page intentionally left blank Table of Contents Table of Contents 1 Introduction... 1.1 Administrator functions overview... 1.2 Network terms and concepts...
Emonitor INSTALLATION MANUAL INSTALLING EMONITOR SOFTWARE WITH A GUPTA SINGLE USER DATABASE
Emonitor INSTALLATION MANUAL INSTALLING EMONITOR SOFTWARE WITH A GUPTA SINGLE USER DATABASE PUBLICATION EMONTR-IN001G-EN-E December, 2013 Supersedes Publication EMONTR-IN001F-EN-E Contact Rockwell Customer
UNICORN 7.0. Administration and Technical Manual
UNICORN 7.0 Administration and Technical Manual Page intentionally left blank Table of Contents Table of Contents 1 Introduction... 1.1 Administrator functions overview... 1.2 Network terms and concepts...
AVG 8.5 Anti-Virus Network Edition
AVG 8.5 Anti-Virus Network Edition User Manual Document revision 85.2 (23. 4. 2009) Copyright AVG Technologies CZ, s.r.o. All rights reserved. All other trademarks are the property of their respective
Contents. 1 Introduction 3 1.1 Purpose... 3 1.2 Target audience... 3 1.3 Overview... 3
Contents 1 Introduction 3 1.1 Purpose............................................ 3 1.2 Target audience........................................ 3 1.3 Overview...........................................
Topaz Installation Sheet
Topaz Installation Sheet P/N 460924001E ISS 08FEB12 Content Introduction... 3 Recommended minimum requirements... 3 Setup for Internet Explorer:... 4 Topaz installation... 10 Technical support... 14 Copyright
User Manual. Onsight Management Suite Version 5.1. Another Innovation by Librestream
User Manual Onsight Management Suite Version 5.1 Another Innovation by Librestream Doc #: 400075-06 May 2012 Information in this document is subject to change without notice. Reproduction in any manner
Diamond II v2.3 Service Pack 4 Installation Manual
Diamond II v2.3 Service Pack 4 Installation Manual P/N 460987001B ISS 26APR11 Copyright Disclaimer Trademarks and patents Intended use Software license agreement FCC compliance Certification and compliance
Metalogix SharePoint Backup. Advanced Installation Guide. Publication Date: August 24, 2015
Metalogix SharePoint Backup Publication Date: August 24, 2015 All Rights Reserved. This software is protected by copyright law and international treaties. Unauthorized reproduction or distribution of this
GE Healthcare Life Sciences UNICORN 5.31. Administration and Technical Manual
GE Healthcare Life Sciences UNICORN 5.31 Administration and Technical Manual Table of Contents Table of Contents 1 Network setup... 1.1 Network terms and concepts... 1.2 Network environment... 1.3 UNICORN
DOCSVAULT Document Management System for everyone
Installation Guide DOCSVAULT Document Management System for everyone 9 v Desktop and Web Client v On Premises Solution v Intelligent Data Capture v Email Automation v Workflow & Record Retention Installing
Imaging Computing Server User Guide
Imaging Computing Server User Guide PerkinElmer, Viscount Centre II, University of Warwick Science Park, Millburn Hill Road, Coventry, CV4 7HS T +44 (0) 24 7669 2229 F +44 (0) 24 7669 0091 E [email protected]
Image Assistant. User Guide. Image Assistant. Laplink Software, Inc. User Guide. The ONLY Way to Restore an Old Image to a New PC!
1 Image Assistant Laplink Software, Inc. Customer Service/Technical Support: Web: http://www.laplink.com/help E-mail: [email protected] Laplink Software, Inc. 14335 NE 24th Street, Suite 201
Partner. Sage Pastel. Accounting. Installation Guide
Sage Pastel Accounting Partner Installation Guide Sage Pastel: +27 11 304 3000 Sage Pastel Intl: +27 11 304 3400 www.pastel.co.za www.sagepastel.com [email protected] [email protected] Sage Pastel Accounting
2. Installation and System requirements
RELEASE NOTES F-Secure Anti-Virus for Windows Servers Version 9.00 build 333 Copyright 1993-2010 F-Secure Corporation. All Rights Reserved. Portions Copyright 2004 BackWeb Technologies Inc. This product
SOFTWARE INSTALLATION INSTRUCTIONS
AUDITGARD LGA Electronic Combination Lock SOFTWARE INSTALLATION INSTRUCTIONS Implementation Package The AuditGard Software implementation package includes: 707013 AuditGard Software Install CD 42145 Programming/Audit
Installation Assistance... 3. Windows/Microsoft Updates... 3. Updating from Spectra 7.0.1 or 7.1... 4. Upgrading from Spectra 6.x...
Spectra 7.1.1/Access 2010 Windows Upgrade Installation Instructions Installation Assistance... 3 Windows/Microsoft Updates... 3 Updating from Spectra 7.0.1 or 7.1... 4 Important Notices... 4 Downloading
VERITAS Backup Exec TM 10.0 for Windows Servers
VERITAS Backup Exec TM 10.0 for Windows Servers Quick Installation Guide N134418 July 2004 Disclaimer The information contained in this publication is subject to change without notice. VERITAS Software
Table of Contents. Introduction...9. Installation...17. Program Tour...31. The Program Components...10 Main Program Features...11
2011 AdRem Software, Inc. This document is written by AdRem Software and represents the views and opinions of AdRem Software regarding its content, as of the date the document was issued. The information
Nexio Connectus with Nexio G-Scribe
Nexio Connectus with Nexio G-Scribe 2.1.2 3/20/2014 Edition: A 2.1.2 Publication Information 2014 Imagine Communications. Proprietary and Confidential. Imagine Communications considers this document and
Manuals for This Product
Installation Guide Manuals for This Product Manuals for this product have the following structure. Read the manual according to your purpose for using this product. Disc Guides with this symbol are PDF
Spector 360 Deployment Guide. Version 7
Spector 360 Deployment Guide Version 7 December 11, 2009 Table of Contents Deployment Guide...1 Spector 360 DeploymentGuide... 1 Installing Spector 360... 3 Installing Spector 360 Servers (Details)...
Core Protection for Virtual Machines 1
Core Protection for Virtual Machines 1 Comprehensive Threat Protection for Virtual Environments. Installation Guide e Endpoint Security Trend Micro Incorporated reserves the right to make changes to this
ESET REMOTE ADMINISTRATOR. Migration guide
ESET REMOTE ADMINISTRATOR Migration guide ESET REMOTE ADMINISTRATOR migration guide Copyright 2012 by ESET, spol. s r.o. ESET REMOTE ADMINISTRATOR was developed by ESET, spol. s r.o. For more information
MGC WebCommander Web Server Manager
MGC WebCommander Web Server Manager Installation and Configuration Guide Version 8.0 Copyright 2006 Polycom, Inc. All Rights Reserved Catalog No. DOC2138B Version 8.0 Proprietary and Confidential The information
GUARD1 PLUS SE Administrator's Manual
GUARD1 PLUS SE Administrator's Manual Version 4.4 30700 Bainbridge Road Solon, Ohio 44139 Phone 216-595-0890 Fax 216-595-0991 [email protected] www.guard1.com i 2010 TimeKeeping Systems, Inc. GUARD1 PLUS
A+ Guide to Software: Managing, Maintaining, and Troubleshooting, 5e. Chapter 3 Installing Windows
: Managing, Maintaining, and Troubleshooting, 5e Chapter 3 Installing Windows Objectives How to plan a Windows installation How to install Windows Vista How to install Windows XP How to install Windows
Administration guide. Host software WinCCU Installation. Complete gas volume and energy data management
Administration guide Host software WinCCU Installation Complete gas volume and energy data management Contents 1 Introduction... 1 Safety first... 1 Warning... 1 Typographic conventions... 1 Product versioning...
ProSystem fx Workpaper Manager. Installation Guide
ProSystem fx Workpaper Manager Installation Guide July 2014 Copyright 2014, CCH INCORPORATED, a part of Wolters Kluwer. All Rights Reserved. Material in this publication may not be reproduced or transmitted,
Additional Requirements for ARES-G2 / RSA-G2. One Ethernet 10 Base T/100 Base TX network card required for communication with the instrument.
TA Instruments TRIOS Software Installation Instructions Installation Requirements Your TRIOS Instrument Control software includes all the components necessary to install or update the TRIOS software, as
http://docs.trendmicro.com
Trend Micro Incorporated reserves the right to make changes to this document and to the products described herein without notice. Before installing and using the product, please review the readme files,
Virtual CD v10. Network Management Server Manual. H+H Software GmbH
Virtual CD v10 Network Management Server Manual H+H Software GmbH Table of Contents Table of Contents Introduction 1 Legal Notices... 2 What Virtual CD NMS can do for you... 3 New Features in Virtual
MAS 90. Installation and System Administrator's Guide 4WIN1010-02/04
MAS 90 Installation and System Administrator's Guide 4WIN1010-02/04 Copyright 1998-2004 Best Software, Inc. All rights reserved. Rev 02 Contents Chapter 1 Introduction 1 How to Use This Manual 1 Graphic
SOS Suite Installation Guide
SOS Suite Installation Guide rev. 8/31/2010 Contents Overview Upgrading from SOS 2009 and Older Pre-Installation Recommendations Network Installations System Requirements Preparing for Installation Installing
Introduction 1-1 Installing FAS 500 Asset Accounting the First Time 2-1 Installing FAS 500 Asset Accounting: Upgrading from a Prior Version 3-1
Contents 1. Introduction 1-1 Supported Operating Environments................ 1-1 System Requirements............................. 1-2 Security Requirements........................ 1-3 Installing Server
Novell ZENworks Asset Management 7.5
Novell ZENworks Asset Management 7.5 w w w. n o v e l l. c o m October 2006 INSTALLATION GUIDE Table Of Contents 1. Installation Overview... 1 If you are upgrading... 1 Installation Choices... 1 ZENworks
Installation Instruction STATISTICA Enterprise Small Business
Installation Instruction STATISTICA Enterprise Small Business Notes: ❶ The installation of STATISTICA Enterprise Small Business entails two parts: a) a server installation, and b) workstation installations
How To Install Database Oasis On A Computer Or Computer (For Free)
INSTALLATION INSTRUCTIONS Table of Contents Installation Instructions 1 Table of Contents 1 System Requirements 2 Installation 3 Selecting where to Install the Professional Server 3 Installing Prerequisites
AXIS Camera Station Quick Installation Guide
AXIS Camera Station Quick Installation Guide Copyright Axis Communications AB April 2005 Rev. 3.5 Part Number 23997 1 Table of Contents Regulatory Information.................................. 3 AXIS Camera
ProSystem fx Engagement. Installation Guide
ProSystem fx Engagement Installation Guide October 2013 Copyright 2013, CCH INCORPORATED and/or its affiliates. All Rights Reserved. Material in this publication may not be reproduced or transmitted, in
Portions of this product were created using LEADTOOLS 1991-2009 LEAD Technologies, Inc. ALL RIGHTS RESERVED.
Installation Guide Lenel OnGuard 2009 Installation Guide, product version 6.3. This guide is item number DOC-110, revision 1.038, May 2009 Copyright 1992-2009 Lenel Systems International, Inc. Information
COMBOGARDPRO. 39E Electronic Combination Lock SOFTWARE INSTALLATION INSTRUCTIONS
COMBOGARDPRO 39E Electronic Combination Lock SOFTWARE INSTALLATION INSTRUCTIONS IMPLEMENTATION PACKAGE The ComboGard Pro Software implementation package includes: 707012 ComboGard Pro Software Install
Ontrack PowerControls V7.2 for Exchange ReadMe
Ontrack PowerControls V7.2 for Exchange ReadMe Contents About the Free Trial System Requirements Mailbox Creation Wizard Installing Ontrack PowerControls Uninstalling Ontrack PowerControls Upgrading Ontrack
ProSystem fx Engagement Installation Guide
ProSystem fx Engagement Installation Guide August 2011 Copyright 2011 CCH INCORPORATED. A Wolters Kluwer business. All Rights Reserved. Material in this publication may not be reproduced or transmitted,
Installation Instruction STATISTICA Enterprise Server
Installation Instruction STATISTICA Enterprise Server Notes: ❶ The installation of STATISTICA Enterprise Server entails two parts: a) a server installation, and b) workstation installations on each of
Embarcadero Performance Center 2.7 Installation Guide
Embarcadero Performance Center 2.7 Installation Guide Copyright 1994-2009 Embarcadero Technologies, Inc. Embarcadero Technologies, Inc. 100 California Street, 12th Floor San Francisco, CA 94111 U.S.A.
Upgrading Client Security and Policy Manager in 4 easy steps
Page 1 of 13 F-Secure White Paper Upgrading Client Security and Policy Manager in 4 easy steps Purpose This white paper describes how to easily upgrade your existing environment running Client Security
Sage ERP MAS 90 Sage ERP MAS 200 Sage ERP MAS 200 SQL. Installation and System Administrator's Guide 4MASIN450-08
Sage ERP MAS 90 Sage ERP MAS 200 Sage ERP MAS 200 SQL Installation and System Administrator's Guide 4MASIN450-08 2011 Sage Software, Inc. All rights reserved. Sage, the Sage logos and the Sage product
INSTALL AND CONFIGURATION GUIDE. Atlas 5.1 for Microsoft Dynamics AX
INSTALL AND CONFIGURATION GUIDE Atlas 5.1 for Microsoft Dynamics AX COPYRIGHT NOTICE Copyright 2012, Globe Software Pty Ltd, All rights reserved. Trademarks Dynamics AX, IntelliMorph, and X++ have been
VERITAS Backup Exec 9.1 for Windows Servers Quick Installation Guide
VERITAS Backup Exec 9.1 for Windows Servers Quick Installation Guide N109548 Disclaimer The information contained in this publication is subject to change without notice. VERITAS Software Corporation makes
ArcGIS 9. Installation Guide: Workgroup for Microsoft SQL Server Express
ArcGIS 9 Installation Guide: Workgroup for Microsoft SQL Server Express Copyright 2006 ESRI All Rights Reserved. Printed in the United States of America. The information contained in this document is the
Proteome Discoverer Version 1.4
Xcalibur Proteome Discoverer Version 1.4 Installation Guide XCALI-97507 Revision A December 2012 2012 Thermo Fisher Scientific Inc. All rights reserved. Xcalibur is a registered trademark of Thermo Fisher
Xactimate v.27 Network Installation
Xactimate v.27 Network Installation Requirements Like all networked software applications, Xactimate Version 27 must be installed on a workstation connected to a network that has been properly set up and
ilaw Installation Procedure
ilaw Installation Procedure This guide will provide a reference for a full installation of ilaw Case Management Software. Contents ilaw Overview How ilaw works Installing ilaw Server on a PC Installing
MRI Commercial. MRI Residential. CRE Manager. Windows Version 4.0 Installation Guide
MRI Commercial MRI Residential CRE Manager Windows Version 4.0 Installation Guide Stock Number: IG40WIN March 2007 2007 Intuit Inc. Any unauthorized use or reproduction of this documentation is strictly
Version Eight. Installation Guide
Version Eight Installation Guide CaseWare IDEA Inc. is a privately held software development and marketing company, with offices in Toronto and Ottawa, Canada, related companies in The Netherlands and
CODESOFT Installation Scenarios
CODESOFT Installation Scenarios NOTES: CODESOFT is a separate install from existing versions of CODESOFT. You will need to make note of your current settings (default directories, etc.) so you can duplicate
StruxureWare Power Monitoring 7.0.1
StruxureWare Power Monitoring 7.0.1 Installation Guide 7EN02-0308-01 07/2012 Contents Safety information 5 Introduction 7 Summary of topics in this guide 7 Supported operating systems and SQL Server editions
FedEx Ship Manager Software. Installation Guide
FedEx Ship Manager Software Installation Guide Before you start Check here to see that your PC has what it needs to run FedEx Ship Manager Software: Minimum System and Hardware Requirements Intel Pentium
e-dpp 4.0.2 May 2013 Quick Installation Guide Microsoft Windows 2003 Server, XP, Vista, 7 Access Database
e-dpp 4.0.2 May 2013 Microsoft Windows 2003 Server, XP, Vista, 7 Access Database ELTECHS Engineering and Consulting Co., Ltd., Japan www.eltechs.co.jp Tel No. +81 (47) 490-1010 Fax No. +81 (47) 490-1011
STATISTICA VERSION 12 STATISTICA ENTERPRISE SMALL BUSINESS INSTALLATION INSTRUCTIONS
STATISTICA VERSION 12 STATISTICA ENTERPRISE SMALL BUSINESS INSTALLATION INSTRUCTIONS Notes 1. The installation of STATISTICA Enterprise Small Business entails two parts: a) a server installation, and b)
http://docs.trendmicro.com
Trend Micro Incorporated reserves the right to make changes to this document and to the products described herein without notice. Before installing and using the product, please review the readme files,
StrikeRisk v6.0 IEC/EN 62305-2 Risk Management Software Getting Started
StrikeRisk v6.0 IEC/EN 62305-2 Risk Management Software Getting Started Contents StrikeRisk v6.0 Introduction 1/1 1 Installing StrikeRisk System requirements Installing StrikeRisk Installation troubleshooting
Sage 100 ERP. Installation and System Administrator s Guide
Sage 100 ERP Installation and System Administrator s Guide This is a publication of Sage Software, Inc. Version 2014 Copyright 2013 Sage Software, Inc. All rights reserved. Sage, the Sage logos, and the
2014 Electrical Server Installation Guide
2014 Electrical Server Installation Guide TITLE: 2014 Electrical Server Installation Guide DATE: September 2013 SUBJECT: ABSTRACT: Installation guide for SolidWorks Electrical 2014 on the server Guide
VERSION NINE. Be A Better Auditor. You Have The Knowledge. We Have The Tools. INSTALLATION GUIDE
VERSION NINE Be A Better Auditor. You Have The Knowledge. We Have The Tools. INSTALLATION GUIDE Copyright October 2012 (v9.0) CaseWare IDEA Inc. All rights reserved. This manual and the data files are
Portions of this product were created using LEADTOOLS 1991-2010 LEAD Technologies, Inc. ALL RIGHTS RESERVED.
Installation Guide Lenel OnGuard 2010 Installation Guide, product version 6.4. This guide is item number DOC-110, revision 1.045, May 2010 Copyright 1995-2010 Lenel Systems International, Inc. Information
Installation Guide for Pulse on Windows Server 2012
MadCap Software Installation Guide for Pulse on Windows Server 2012 Pulse Copyright 2014 MadCap Software. All rights reserved. Information in this document is subject to change without notice. The software
Table of Contents. FleetSoft Installation Guide
FleetSoft Installation Guide Table of Contents FleetSoft Installation Guide... 1 Minimum System Requirements... 2 Installation Notes... 3 Frequently Asked Questions... 4 Deployment Overview... 6 Automating
Server Sentinel Client Workstation
Server Sentinel Client Workstation Installation and Reinstallation Guide Server Sentinel 4.4.3 and Higher April 2008 . unisys imagine it. done. Server Sentinel Client Workstation Installation and Reinstallation
Guide to Installing BBL Crystal MIND on Windows 7
Guide to Installing BBL Crystal MIND on Windows 7 Introduction The BBL Crystal MIND software can not be directly installed on the Microsoft Windows 7 platform, however it can be installed and run via XP
Design Better Products. SolidWorks 2009. SolidWorks Enterprise PDM Installation Guide
Design Better Products SolidWorks 2009 SolidWorks Enterprise PDM Installation Guide 1995-2008, Dassault Systèmes Dassault Systèmes SolidWorks Corporation, a Dassault Systèmes S.A. company. 300 Baker Avenue
Contents. Hardware Configuration... 27 Uninstalling Shortcuts Black...29
Contents Getting Started...1 Check your Computer meets the Minimum Requirements... 1 Ensure your Computer is Running in Normal Sized Fonts... 7 Ensure your Regional Settings are Correct... 9 Reboot your
Legal Notes. Regarding Trademarks. 2013 KYOCERA Document Solutions Inc.
Legal Notes Unauthorized reproduction of all or part of this guide is prohibited. The information in this guide is subject to change without notice. We cannot be held liable for any problems arising from
Installation Guide for Workstations
Installation Guide for Workstations Copyright 1998-2005, E-Z Data, Inc. All Rights Reserved. No part of this documentation may be copied, reproduced, or translated in any form without the prior written
Installing GFI MailSecurity
Installing GFI MailSecurity Introduction This chapter explains how to install and configure GFI MailSecurity. You can install GFI MailSecurity directly on your mail server or you can choose to install
Reporting for Contact Center Setup and Operations Guide. BCM Contact Center
Reporting for Contact Center Setup and Operations Guide BCM Contact Center Document Number: NN40040-302 Document Status: Standard Document Version: 04.00 Part Code: N0060637 Date: June 2006 Copyright 2005
@ptitude Observer. Installation Manual. Part No. 32170700 Revision G
Part No. 32170700 Revision G Installation Manual Copyright 2012 by SKF Reliability Systems All rights reserved. Aurorum 30, 977 75 Lulea Sweden Telephone: +46 (0) 31 337 10 00, Fax: +46 (0) 920 134 40
Symantec AntiVirus Corporate Edition Patch Update
Symantec AntiVirus Corporate Edition Patch Update Symantec AntiVirus Corporate Edition Update Documentation version 10.0.1.1007 Copyright 2005 Symantec Corporation. All rights reserved. Symantec, the Symantec
Migrating MSDE to Microsoft SQL 2008 R2 Express
How To Updated: 11/11/2011 2011 Shelby Systems, Inc. All Rights Reserved Other brand and product names are trademarks or registered trademarks of the respective holders. If you are still on MSDE 2000,
MS SQL Installation Guide
MS SQL Installation Guide Microsoft SQL Database For Debtors Manager Table of contents 1. Overview 2. Minimum server installation requirements for MS SQL 3. Installing MS SQL on your server 4. Installing
TECHNICAL SUPPORT GUIDE
TECHNICAL SUPPORT GUIDE INTRODUCTION This document has been developed to provide a guideline for assisting our clients and their technicians with a standard Console Gateway Live configuration. IS THIS
Networking Best Practices Guide. Version 6.5
Networking Best Practices Guide Version 6.5 Summer 2010 Copyright: 2010, CCH, a Wolters Kluwer business. All rights reserved. Material in this publication may not be reproduced or transmitted in any form
BCA Software Installation and Troubleshooting Guide
BCA Software Installation and Troubleshooting Guide This document contains four components: Prerequisites provides the list of prerequisites and system requirements to successfully install and run the
FAS Asset Accounting FAS CIP Accounting FAS Asset Inventory SQL Server Installation & Administration Guide Version 2011.1
FAS Asset Accounting FAS CIP Accounting FAS Asset Inventory SQL Server Installation & Administration Guide Version 2011.1 2011 Sage Software, Inc. All rights reserved. Published by Sage 2325 Dulles Corner
Administrator Manual Across Personal Edition v6 (Revision: February 4, 2015)
Administrator Manual Across Personal Edition v6 (Revision: February 4, 2015) Copyright 2004-2015 Across Systems GmbH The contents of this document may not be copied or made available to third parties in
Mobility Services Platform 3.1.1 Software Installation Guide
Mobility Services Platform 3.1.1 Software Installation Guide Mobility Services Platform 3.1.1 Software Installation Guide 72E-100159-04 Revision D January 2008 2007 by Motorola, Inc. All rights reserved.
Dell Statistica 13.0. Statistica Enterprise Installation Instructions
Dell Statistica 13.0 2015 Dell Inc. ALL RIGHTS RESERVED. This guide contains proprietary information protected by copyright. The software described in this guide is furnished under a software license or
WhatsUp Gold v16.3 Installation and Configuration Guide
WhatsUp Gold v16.3 Installation and Configuration Guide Contents Installing and Configuring WhatsUp Gold using WhatsUp Setup Installation Overview... 1 Overview... 1 Security considerations... 2 Standard
HP Business Availability Center
HP Business Availability Center for the Windows and Solaris operating systems Software Version: 8.05 Business Process Monitor Administration Document Release Date:September 2010 Software Release Date:
Getting Started with. Ascent Capture Internet Server 5. 10300260-000 Revision A
Ascent Capture Internet Server 5 Getting Started with Ascent Capture Internet Server 5 10300260-000 Revision A Copyright Copyright 2001 Kofax Image Products. All Rights Reserved. Printed in USA. The information
TECHNICAL DOCUMENTATION SPECOPS DEPLOY / APP 4.7 DOCUMENTATION
TECHNICAL DOCUMENTATION SPECOPS DEPLOY / APP 4.7 DOCUMENTATION Contents 1. Getting Started... 4 1.1 Specops Deploy Supported Configurations... 4 2. Specops Deploy and Active Directory...5 3. Specops Deploy
InventoryControl for use with QuoteWerks Quick Start Guide
InventoryControl for use with QuoteWerks Quick Start Guide Copyright 2013 Wasp Barcode Technologies 1400 10 th St. Plano, TX 75074 All Rights Reserved STATEMENTS IN THIS DOCUMENT REGARDING THIRD PARTY
Symantec Backup Exec 12.5 for Windows Servers. Quick Installation Guide
Symantec Backup Exec 12.5 for Windows Servers Quick Installation Guide 13897290 Installing Backup Exec This document includes the following topics: System requirements Before you install About the Backup
Important. Please read this User s Manual carefully to familiarize yourself with safe and effective usage.
Important Please read this User s Manual carefully to familiarize yourself with safe and effective usage. About This Manual This manual describes how to install and configure RadiNET Pro Gateway and RadiCS
LockView 4.3.1 CompX Database & Network Configuration & Installation Manual
LockView 4.3.1 CompX Database & Network Configuration & Installation Manual Table of Contents CompX Database & Network Configuration & Installation Manual Introduction... 4 Installation Requirements...
User Guide. Windows 8 Upgrade Assistant. Laplink Software, Inc. MN-PCM-UpgdAssist-EN-08 (REV. 10/2012)
1 Windows 8 Upgrade Assistant User Guide Laplink Software, Inc. For technical support issues or questions, please visit: http://www.laplink.com/contact For other inquiries, please see contact details below:
U90Ladder / VisiLogic /UniLogic and software utilities system requirements. Contents
U90Ladder / VisiLogic /UniLogic and software utilities system requirements Contents Minimum System Requirements... Error! Bookmark not defined. UniLogic Installation... 3 Firmware Update and Management...
