1 Report of technical survey of hull, Construction and installation. File number : Place of survey: Sante Teresa di Gallura, Italy. Craft s name: Winslow Bay Date of survey: and Registration number: T [email protected] Tel Page 1 van 24 file number:
2 Table of content Chapter cover page Table of contents 1. Definitions 2. General data 3. Ship data 4. Craft documents 5. Hull under water 6. Hull above water 7. Deck/superstructure 8. Hull inside 9. Tanks, Galley, and comfort, 10. interior 11. Electric installation 12. Navigation equipment 13. Steering gear 14. Propulsion and engine 15. generator 16. Sea trial 17. Safety and life saving appliances 18. Conclusion 19. Closure 20. Photo s 2. annex - terms and conditions - Hull layout photo s Page 2 van 24 file number:
3 1. Definitions I n this report observations and findings with regard to the survey and the sea trial are sum up in this report. The subheading is as show below. The observations and findings are marked in a 5 point system. The observations are indicative and are not guaranteed. Five (5) good - No remarks new state - No corrective maintenance to be expected within 12 calendar months after inspection - No preventive maintenance is to be expected within 12 calendar months from inspection - apply normal scheduled maintenance. four(4) more than sufficient - Virtually no comments, used condition - No corrective maintenance to be expected within 12 calendar months from inspection - No preventive maintenance is to be expected within six calendar months from inspection - apply normal scheduled maintenance Three (3) sufficient - Several remarks, used condition - No corrective maintenance to be expected within six calendar months from inspection - Preventive maintenance may be expected - apply normal scheduled maintenance Two (2) moderate - Too many comments, worn condition - Corrective maintenance may be necessary - Preventive maintenance necessary - Periodic maintenance necessary but is not enough - Use is possible but is not recommended; it that repair or replacement is recommended - Unsafe situation One(1) bad - Too many comments, unusable state - Corrective maintenance necessary - Preventive maintenance necessary - Periodic maintenance necessary - Before use is in consideration replacement/repair/maintenance should be carried out. - Unsafe situation Some reviews have been answered "Yes/No". In most cases meaning: No ; the evaluated requires no further attention. Yes ; the evaluated requires further attention. NI P ; Not inspected ; present ; not present Page 3 van 24 file number:
4 2. General data Pre- purchase survey Client: The purpose of this survey is to inspect if the craft is in the conditions conform the survey report of Mr. Marco Mureddu signed up on Client of van den Enden Ship Yard Address Industriesweg 43 code/place 5145 PD Waalwijk phone mail owner [email protected] M. Napoleone Address Postal code town Survey carried out by J.P.H.G.van Baars Address Duinweg 131 code/town 1871 AH Schoorl phone / mob. mail certification Place of survey Other Attendees Type of vessel brand/type [email protected] EMCI certified yacht surveyor Sardinië Broker, Claudio Simonazzi Motor Yacht Benetti 66 Delfino boatyard Benetti design Benetti Navali CIN-code Not available ; built before june 1998 registration VG 4739 D Vat Details : Page 4 van 24 file number:
5 3. Ship data dimensions Length: 19,96 Beam: 5.10 Draft: 1.60 Construction year 1969 Material Steel hull and aluminum superstructure Hull number FB 80 carved in aluminum bulkhead in lazarette displacement 65 ton ballast Lead bars behind carpentry. 4. Craft documents Measurement certificate Local registration yes Viareggio Rina certification yes Crew list VAT statement Not present insurance Proof of ownership Not present during survey proof of debt free acquisition Not present during survey For information: if going on information provided by third parties, and may be incorrect or incomplete, van Baars expert recreational craft is not responsible for it, nor for the consequences of this. Page 5 van 24 file number:
6 5. Hull under water/osmosis investigation Value details Stat of Hull underwater 2 Leaks and insufficient material thickness caused by corrosion from the inside, see attachment: hull layout Ultrasonic measurement 2 keel 4 No visual defects Coating system 1 Insufficient protective paint under antifouling Anodes 3 Due to insufficient paint anodes are almost worn after 4 months. Corrosion yes Local. But complete underwater hull must be maintained Damage yes Cooling water intake, bolds are missing propellershafts 4 No deformation Propellershaft bearings 4 Clearing within tolerances Exhaust pipe 3 Corrosion inside and outside. Cooling intake 2 Mounting bolts missing Propellers 4 Little deformation of blade tips. Well within tolerance. bowprop Sternprop Rudders 4 Rudder bearings 4 Heel trim tabs 3 General condition 2 For information: in case of ultra sonic testing the results come from local measuring therefore variables are possible in not measured places. Problems in and/or below the applied paint systems, or other not reachable places, can only be determined after destructive testing. This destructive testing Word does not run in response to this inspection. Page 6 van 24 file number:
7 6. Hull above water value details Coating 2 Many blisters damage yes Big deformation (dent) in the hull on starboard bow Loose layers of paint yes Cracks and blisters in the filler and the paint. Fender rail Non present Too rail Non present bulwark 4 Deck/hull connection 4 General condition 3 In regards with the given defects. For information survey under the applied paint systems and layers of filler can only be adopted after destructive testing. This destructive research is not carried out at the inspection. Page 7 van 24 file number:
8 7. Deck and super structure value details Material 2 Aluminium locally heavily corroded Coating 2 Many loose layers of paint Deck cover 1 teak deck leaking and corrosion traces of the deck below are visible. Construction of deck tools 2 Some deck tools are only connected to the teak. Due to corrosion of the under laying steel deck. Coating superstructure 1 Many heavy blisters Cover of super structure Deck cover rear deck 2 Teak is not water tide. Deckhouse mounting 1 Rivets are gone and corrosion in aluminum as well as steel has affected the construction. Teak cover of this connection is not water tide and leaks are visible on the inside due to this problem. chain locker 1 Due to the construction maintenance is not possible. Corrosion has affected the deck as well as the hull. Steel plating interior must be removed to inspect the hull under this locker. Ultrasonic testing show a very bad condition of the hull underneath the chain locker winch 4 Shutters/window/ports 3 They do show aesthetic defects. Ports are leaking due to defect rubber seal. Window wipe installation 2 Only a centrifuge window present this is insufficient. railing Fly bridge 3 4 Main deck Tender retrieve 3 installation General condition 2 Note: the internal condition of the deck, and superstructure, as well as the connection of the teak deck to the steel are not possible without destructive resurge, this resurge will not be carried out be van Baars Expert recreational craft Page 8 van 24 file number:
9 8. Hull inside value details State of preservation 1 Corrosion and degradation of parts are visual though out the hole bilge of the craft. Degradation of parts yes Frames are affected by corrosion. Visible leak yes Due to hull leaks and leaks in the deck, also leaks from showers and bathrooms. Water in bilge no But during the inspection it was obvious that bilges has been drained shortly before the survey. Long- and cross sectors 2 Constructively ok but corrosion affected many frames. Coating 2 Hull through fittings 3 There where fittings are mounted(storage room) insufficient conservation. Sea cocks 4 2 valves are disconnected therefore blinds should be mounted on these valves. plumbing 2 Partly disconnected and corroded Hose clamps 4 Shutters, Windows, ports 3 Aesthetic defects and ports are not water tide due to defect rubber seal Bilge 1 Heavily corroded Deck-structure connection 1 leaks General condition 2 In regards to the remarked defects. For information: the condition of the hull on the inside, under ballast or in keels, under concrete or other solid materials connected to the hull, are not surveyed without destructive inspection. Destructive inspection is no part of this survey Page 9 van 24 file number:
10 9. Tanks/galley/comfort Value Material details freshwater tank(s) 3 steel All tanks should be opend to inspect the interior. Waste water holding tanks carbon filter Toilet 1 Plumbing corroded and crew cabin toilet not mounted. fridges 3 Working with a central compressor in engine room. icemaker Freezer 3 stove 4 Oven/microwave heating Not tested Boiler/water heater Not tested Fresh water maker 5 Newly installed, installation in unprofessional way. air-conditioning Not tested. 10. Interior Timber work 4 original detail still present Upholstery 4 No major defects detected. Equipment 3 Working Not according modern standard Vessel interior is in sufficient condition the classic and original details work positive for this type of craft. Storage space 4 showers 1 Al bathroom floors are leaking General impression 3 For information: Tanks can are not filled by vanbaars Expert Recreational Craft When a manhole a manhole or inspection hatch on tanks is absence present. Van Baars expert recreational craft can exclusively by endoscopic research inspect the inside of tanks. This gives a limited result (s) found. Therefore A reservation is made. Page 10 van 24 file number:
11 11. Electric installation value details Ship installation 12 volt AC 24 Volt AC 220 volt DC 380 volt DC main switches 3 Capacity of the switch is sufficient for the current installation. When the overall installations is transformed to the modern standards the switches are insufficient. Group switches 4 fuses 3 working old Shore connection 2 No circuit breaker or isolation transformer Solar cels Wind generator Circuit breaker no alternator 4 Ac and DC Generator 4 Onan 12 KVA Charger and 220 Cabin switches 3 Navigation lights 4 Batteries sea tide 4 batteries ventilated 4 Condition of batteries 4 Starter batteries 4 Onan batteries 4 Service batteries Electric wiring 3 Cluttered but functional General condition 3 Note: for wiring and connections that can't be reached or in not accessible space reservation are made. Electrical installation is only evaluated in how far this one works. Page 11 van 24 file number:
12 12. Navigation equipment present tested function brand compass yes yes yes Sestrel VHF/dsc yes yes yes Sailor Rudder indicator yes yes yes Atis No Radio/ssb No Gps No speedo No Navtex No Radar yes No autopilot yes yes yes Neco Depth sounder No Anemometer No Repeaters No Plotter yes No Radio/cd yes yes Yes For information: the assessment "works" is not to say that the designation is correct. Reservation for this part are made. Page 12 van 24 file number:
13 13. Steering gear Wheel/helm 4 Oil leakage yes In Lazaretto Backlash 5 Rudder angel restricted 4 seals 4 cylinders 4 console 4 Rudder Trunk 2 Heavily corroded and leaks detected around the rudder trunk. General condition 3 In regard to mentioned defect Page 13 van 24 file number:
14 14. Propulsion and engine Value details Main engine PS Type 120VA number Construction 4 Solid Flexible 1967 Engine mountings 4 Alignment of engine and propeller shaft good. Crankshaft 2 Seals leaking Engine foundation 4 leak traces yes Water Oil fuel Seals and gaskets leaks. Corrosion traces yes Superficial Reversing gear Hydraulic mechanical Twindisk Cooling system closed Direct indirect Seaweed filter 1 None pressent Air vent 2 Exhaust system 1 wet Dry Isolated with asbestos!!! Exhaust noise 5 Main engine SB Type 12VA Number Construction 4 Solid Flexible 1967 Engine mountings 4 Crankshaft 3 Seal appear to be ok but expectations are that seals must be changed. Engine foundation 4 leak traces yes Water Oil fuel Seals and gaskets leaks. Corrosion traces yes Superficial Reversing gear 4 Hydraulic Mechanic Twindisk Cooling system closed Direct Indirect Seaweed filter 1 None present Air vent 2 Exhaust system 1 wet dry Isolated with asbestos!!! Exhaust noise 5 Fuel tank(s) 3 internal inspection not possible, light corrosion on tanktop. Tank content 4500 litre Installation tank 3 Corrosion and not maintainable due to carpentry. Day tank Not present Water separator 3 On fuel filter Aerate tanks 4 Engine remote control 4 Mechanical by cable and chain. Propeller shaft installation 3 Portside gland is leaking sea water. Page 14 van 24 file number:
15 Fuel valves 4 Closable on deck 4 According to Rina rules General impression 3 engine room Conservation engine 2 room Thrust bearing None present Leakage propeller shaft yes gland Water lubricated Oil lubricated Grease lubricated Air intake 1 Complete corroded. 15.Generator Diesel petrol Power 12 Kva type 12.om DJR # Mounting 4 Flexible mountings 4 Construction 2 Cover show minor defects Leaks yes Seawater intake pump leaks. Cooling 4 Exhaust 3 Constructed out of gas pipes. Corroded inside. Noise 5 Starter battery 5 Information: flexible engine mountings must be audited annually for cracks, we recommend flexible engine mountings to be replaced after 10 years. For rubber seal and cuffs is an annual inspection advisable and replaced as recommended by the manufacturer specifications. Inspections of engines and mechanical parts relate to a moment, there are no guarantees based on the advice of repairs or replacement of parts. Laboratory testing of lubricants does not belong to this inspection. These can be run on demand. Page 15 van 24 file number:
16 16. Sea trial Behaviors and effects to be assessed in a 3 digit from 0 to 3 where: *1 = poor *2 = average *3 = excellent Location Weather visibility Wind force Wind direction Mediterranean sea north of Sardinia Good Good 4 BFT NE value details Bow thruster Stern thruster Steering behavior 2 Vibration 2 Due to solid engine mounting resonance 2 Gear clutch 3 Engine remote control 2 Acoustic alarm 2 Behavior full ahead 1 Did not reach maximum rpm of 2200 Behavior full sb 2 Behavior full port 2 behavior ahead/ astern 3 Maneuverability astern 1 Small rudders, maneuvering must be done with engines. Engine readings during trial Starboard engine Portside engine Oil temp. 78 C 77 C Oil pressure 3.5 bar 4.0 Bar Water temp Gear box pressure Hour according indicator +/ /-2100 Page 16 van 24 file number:
17 17. Safety and lifesaving appliances present Test cert. details Fire extinguishers yes yes Rina Engine room yes yes Rina regulations extinguisher Emergency signals No lifebuoy yes Yes life raft self inflating yes Yes lifejacket Yes first aid kit No Fire alarm /smoke No detectors Burglar alarm No Emergency steering yes In Lazarette anchor yes 2 bow anchors of sufficient weight bilge pumps yes yes Several electric bilge pumps and 1 mechanical pump on main engine. tender yes no On fly bridge Page 17 van 24 file number:
18 18. Conclusion The survey, done by van Baars Expert Recreational Craft of the craft with the details in the pages before, results in the following review: the overall condition and state of maintenance is poor This report of findings is carried out for Client of van den Enden Ship Yards to get a clear picture of the technical state and Construction of the craft. And if the craft is in the state as given by mr. Marco Mureddu During the survey we discovered that the Craft is nowhere near the state as it was mentioned by my colleague mr. Marco Mureddu. Hull outside: During the inspection the hull was painted with 2 layers of antifouling. The protective coating beneath the antifouling is less than 125µ and therefore insufficient to protect the craft against corrosion. The heavily affected anodes (mounted in july 2011) show that electrolyses is a problem. Welds are in good condition as far as visual inspection is possible. In Attachment 1A, you can find the results of the ultrasonic measurements. Here you will find that the maximum material thickness is between less than zero millimeter (leak) and 4.2 millimeters, therefore we can conclude that the craft was originally build of 5 millimeter steel underwater and 4 millimeter freeboard above the waterline. This in contrast with the 7 millimeter. In this attachment we suggested the repairs that have to be made to ensure a minimum hull thickness of 3 millimeters and a 10% margin. Which is required by insurance companies. Repair should be made from steel no less than 5 millimeter thickness. Because corrosion is starting from the inside of the hull and preparation and conservation of the original hull is not possible in the current state we advice to remove old hull material and replace for new. Propeller and propeller shafts are in good condition as far as visual inspection is possible. Also the rudders and flaps are in well working condition. cost planning ,= Leaks occurred during the survey Page 18 van 24 file number:
19 Hull inside: The hull inside is very badly protected against corrosion due to saltwater and bad paint condition the hull material as well as the framework is heavily corroded. Parts of the frame work are completely missing an repairs must be made. The inside of the fuel tanks are not inspected because the manholes are not accessible. Corrosion in the fuel tanks is well possible Cost planning ,= lazarette owners cabin. crew cabin. heavily corroded framework and hull material. Deck and super structure: The connection between deck and superstructure is in a very bad condition. The connection is originally riveted, most rived are no longer connected to the aluminum with loss of constructive strength and leak as a result. The wooden cover of this connection is also detached from the aluminum and the steel deck, with wood rotting as a result. The teak deck has been sanded down with material loss as a result. Rubber seal are partly gone and the teak deck is no longer water tide. Sea water is locked up in between the steel deck and the teak deck cover. Therefore corrosion of the child steel deck is inevitable. Corrosion water is visual all over the gangways. Some deck tools are loose from the constructive steel due to this corrosion. The coating on the aluminum superstructure is bad condition this is partly caused by the defect in the connection with the steel deck. At the foredeck a wooden bench is mounted. This bench is no longer is a usable state and must be renewed. This is also necessary because the teak deck the mounted underneath this bench. Cost planning recovery of the teak deck 60m ,= Cost planning recovery of the deck super structure connection ,= Cost planning repairs of bench ,= Page 19 van 24 file number:
20 problems with the aluminum steel connection wood rotting on the deck. worn and leaking teak deck. wood rotting in the bench on the foredeck. corrosion of the steel deck under the teak. Page 20 van 24 file number:
21 Carpentry and interior: The carpentry and interior show also defects due to leaks from the inside as well is from the outside in. the main problem of the leaks is the connection between the deck and the super structure. Windows shutters and portholes are also no longer water tide. Besides these problems all the bathroom floors are leaking. This results in wood rotting and corrosion of the hull. Therefore these problems should be repaired to prevent further deterioration on the inside. Cost planning repairs bathroom floors ,= Cost planning repairs of portholes 500,= Cost planning repairs of visual defects of carpentry ,= Overall installations: In general the installations are in a condition that can be expected from a craft from this age. There are however some problems. The electric installation is old and is missing an isolation converter to prevent electrolyses. The rest of the electrics is functional but not according to the modern standards which of course can be expected from a craft from this age. All plumbing in the craft is made out of steel pipes. Some emergency repairs have been made. But we advice to remove all the steel plumbing and exchange it for hoses with the right specifications. Cost planning electric installation ,= Cost planning repairs of plumbing 8.500,= Page 21 van 24 file number:
22 Engine room and machinery: During the survey we had the impression that the machinery is maintained reasonable. partly caused by the age of the vessel I discovered the following problems and defects. Gland of portside engine is leaking. Cost planning 250,= Exhaust is covered with highly toxic asbestos! Cost planning 2000,= Crankshaft seal from port side engine is leaking oil. Cost planning 750,= Air intake for the engine room is completely corroded. This makes it possible that seawater and rain can come into the engine room. Cost planning 2000,= Out board cooling water pump of the generator is leaking. Cost planning 250,= Both engines have several leaking gaskets with oil, water and fuel leak as a result. Cost planning 6.500,= Hydraulic helm system is leaking in the after peak(lazarette). Cost planning 275,= Overall engine room ,= Page 22 van 24 file number:
23 asbestos on the exhaust. Air intake corroded steering hydraulics leaking. water pump generator leaking. Page 23 van 24 file number:
24 19. Closure Although the intention of the survey is to give a complete report about the state of the vessel at the moment of the survey and the detected derogations and defects, this report excludes not one unlisted or undetected derogation or defect of the vessel. Therefore should be regarded as not been reviewed, it also should be noticed that on all the services of vanbaars expert recreational craft our terms and conditions apply. This survey is a snapshot, van Baars Expert Recreational craft cannot guaranty that the yacht will stay in the condition as is during the survey. The report is only for the originator of the inspection. No responsibility is accepted for use by third parties or for the benefit of other vessels or parts of it. The pages of this report are marked by a stamp and a signature. Made with best intentions, knowledge and skills. sans préjudice Thus put up, Date: Place: Schoorl Name: Boj van Baars Director of van Baars Expert Recreational Craft Page 24 van 24 file number:
25
Competency Framework for Marine Engineer Class 6. Competency Framework for Marine Engineer Class 6
Table of Contents (MEC 6)... 1 Function: Operate Vessel Machinery and Systems... 1 Diesel engines.... 1 Operational procedures.... 3 Operate and monitor a vessel s engines and auxiliary equipment.... 4
MARKEL AMERICAN INSURANCE COMPANY POWERBOAT SELF SURVEY EVALUATION FORM
Our records reflect that a Condition and Value survey is due for your boat. A Condition and Value survey performed by a competent marine surveyor is the best way to determine if there are any defects or
WELLCRAFT SCARAB WELLCRAFT
WELLCRAFT SCARAB WELLCRAFT Builder: WELLCRAFT Year Built: 1989 Model: High Performance Price: $249,999 USD Off the market LOA: 50' 0" (15.24m) Beam: 9' 4" (2.84m) Min Draft: 2' 2" (0.66m) Max Draft: 3'
Drettmann Explorer Yacht DEY 32
Drettmann Explorer Yacht DEY 32 Short Specifications General The Yacht will be designed and built to provide 10 guest berths in the owner cabin and chartering for a maximum of 10 passengers. The modern
PRICE ON REQUEST VAT NOT PAID FIPA GROUP
1 MAIORA 23 NEW Builder Fipa Group Length Overall 23.60 meters (77ft.5in.) Type Flybridge Motoryacht Beam 5.80 meters (19ft.) Model Maiora 23 Draft 1.60 meters (5ft.4in.) Year NEW (2013 model) Construction
Part 0 - Classification and Surveys Classification and Surveys I-0 2016-01
Code Edition I - Ship Technology Part 0 - Classification and Surveys Classification and Surveys I-0 2016-01 Part 1 - Seagoing Ships Chapter 1 - Hull Structures I-1-1 2016-01 Chapter 1 - Hull Structures
Arcona 410 Juniper. Arcona Yachts UK. Hamble Point Marina, School Lane, Hamble, Southampton, Hampshire SO31 4NB United Kingdom
Arcona 410 Juniper Make: Arcona Model: 410 Length: 12.2 m Price: GBP 225,000 Tax Status: Tax Paid Year: 2011 Condition: Used Draft: 2.2 m Hull Material: Fibreglass (GRP) Designer: Builder: Fuel Type: Location:
POSEIDON ISLA TRAWLERS 2600
POSEIDON ISLA TRAWLERS 2600 Principle Dimensions: LOA: 26.61 m (87 ft 4 in) LWL: 23.90 m (79 ft 5 in) B max: 6.60 m (21 ft 7 in) Draught max: 1.90 m (6 ft 2 in ) D: 3.27 m (10 ft 8 in) Full Displacement:
LEOPARD 27M SPECIFICATIONS
LEOPARD 27M SPECIFICATIONS MODEL: 27m LENGTH: 27m SHIPYARD: Leopard (Arno) BEAM: 6.05m YEAR: 2002 DRAFT: 1.75m ENGINES: MTU 16V2000 M91 DISPLACEMENT: N/A TYPE: 2 x 2.000 hp (1.110h) ACCOMMODATION: 3 cabins
All Marine Solutions
All Marine Solutions PREMIUM MARINE MAINTENANCE, INSTALLATION AND REPAIR Marine Plumbing Marine Water Treatment Bow and Stern Thruster Fibreglass Gelcoat Timber Paint Work Marine Fit-outs SERVICE EXCELLENCE
Report Index PROPERTY DESCRIPTION 1 ELECTRICAL SYSTEM 2 COMMON INTERIOR AREAS 3 INTERIOR ROOMS 6 KITCHEN 8 BATHROOMS 10
Report Index PROPERTY DESCRIPTION 1 ELECTRICAL SYSTEM 2 COMMON INTERIOR AREAS 3 INTERIOR ROOMS 6 KITCHEN 8 BATHROOMS 10 PROPERTY DESCRIPTION PROPERTY INSPECTED: INSPECTION ADDRESS: 4722 Baltimore Avenue
Dit formulier is eigendom van Panta Rhei Brokerage. forepeak with cupboard - u-settee port - bunk on starboard - Layout description
Type / model Van de Stadt Caribbean 40 Description in one sentence Fast and sturdy cruiser for all seas Owners 1 owner Cruising area and voyages St. Malo - Schotland - St. Petersburg Length overall (feet)
Crawford Inspection Services C.C.B. # 76914 www.crawfordinspections.com
Crawford Inspection Services C.C.B. # 76914 www.crawfordinspections.com Portland Area PO Box 665 West Linn, OR 97068 Ph: (503) 650-6957 Salem Area 5434 River Rd. N; #192 Keizer, OR 97303 Ph: (503) 362-5809
LAGOON CATAMARANS PRICE LIST IN EURO A 2016
LAGOON CATAMARANS PRICE LIST IN EURO A 2016 CATAMARANS ENGINES STANDARD BOAT EQUIPMENT PACK * ADDITIONAL EQUIPMENT TRANSPORT LAUNCHING, RIGGING & ANTIFOULING LA-ROCHELLE ** (ATLANTIC) TOTAL PRICE LAGOON
Does Wall Township require an inspection by the building department on resale of a home?
Selling your home Does Wall Township require an inspection by the building department on resale of a home? No. We do not require a Certificate of Continued Occupancy on the resale of home. A Smoke Detector,
CODECASA 35M. MATERIAL: Steel hull/ ASKING PRICE: Euro 8 400.000 (ex VAT)
CODECASA 35M BUILDER: Cantieri Codecasa LOA: 115 / 35m YEAR: 2003 BEAM: 23 4 / 7.20m FLAG: Cayman Island SPEED: 15.0 knots maximum ACCOM: Four cabins for ten guests. Three cabins for five crew. MATERIAL:
Trevilling Quay Wadebridge Cornwall PL27 6HF
Power Catamarans Limited Powerglide 46 46 Trevilling Quay Wadebridge Cornwall PL27 6HF Tel:- 01208 814876 Specifications PowerGlide 40 PowerGlide 46 Length Overall 12.2m Beam max 5.05m Depth of Hull amidships
BENETEAU YACHTS PRICE LIST IN EURO 01.2016
BENETEAU YACHTS PRICE LIST IN EURO 01.2016 3/2/2016 BENETEAU CABINS ENGINE STANDARD BOAT TRIM LEVEL * ADDITIONAL EQUIPMENT TRANSPORTATION TO THE SOUTH OF FRANCE INSTALATION OF EQUIPMENT ANTIFOULING PREPARATION
A.1 Obligations and reporting of the gaining Society. Plans to be Submitted by the Owner to the Gaining Society
(Rev.0 July 2009) (Rev.1 June 2012) (Rev.2 Oct 2013) (Rev.3 Jan 2015) (Rev.4 July 2015) (Rev.5 Jan 2016) Procedure for Transfer of Class TABLE OF CONTENTS Procedure for Transfer of Class Application Definitions
Sea Ray 340 Express Cruiser Joan of Art
Sea Ray 340 Express Cruiser Joan of Art Make: Model: Length: Sea Ray 340 Express Cruiser 34 ft Price: $ 15,500 Year: 1985 Engine Make: Crusader Location: Marblehead, OH, United States Boat Name: Hull Material:
AUTOMOBILE MECHANIC STUDENT INTERNSHIP SKILLS LIST Provo School District
AUTOMOBILE MECHANIC STUDENT INTERNSHIP SKILLS LIST Provo School District Repairs and overhauls automobiles, buses, trucks, and other automotive vehicles: Examines vehicle and discusses with customer or
SAILBOAT 2015 ENGINES, OPTIONS AND NEWS
SAILBOAT 2015 ENGINES, OPTIONS AND NEWS 2 A MATTER OF RELIABILITY A MATTER OF RELIABILITY Whether you see sailing as a purely fun and relaxing pastime or as a challenge to conquer sea and wind, you always
BOROUGH OF NATIONAL PARK APPLICATION FOR A CERTIFICATE OF OCCUPANCY FOR CHANGE OF OCCUPANCY ADDRESS OF PROPERTY FOR INSPECTION CURRENT OWNER
BOROUGH OF NATIONAL PARK APPLICATION FOR A CERTIFICATE OF OCCUPANCY FOR CHANGE OF OCCUPANCY ADDRESS OF PROPERTY FOR INSPECTION # BLOCK LOT VACANT YES NO CURRENT OWNER NAME ADDRESS TELEPHONE # PROSPECTIVE
Instruction Manual for Operating Panel 301 and 302
Instruction Manual for Operating Panel 301 and 30 Edition: 1/006 Edition: 1/006 Contents 1 Introduction and Overview........................ 5 1.1 Panel 301 Controls........................................
COMPREHENSIVE PROPERTY INSPECTIONS
COMPREHENSIVE PROPERTY INSPECTIONS Thank you for selecting CPI for your Deficiency Observation. A full home inspection was not performed on this property at the buyers request. This inspection is a limited
VOLVO PENTA DIESEL AND GASOLINE ENGINES LAYING-UP AND LAUNCHING GUIDE
VOLVO PENTA DIESEL AND GASOLINE ENGINES LAYING-UP AND LAUNCHING GUIDE TIME WELL INVESTED This guide covers most of the items to be checked and seen to on your engine and drive when laying up and launching.
www.citiesinspection.com October 5, 2015 Dear Client,
www.citiesinspection.com October 5, 2015 Dear Client, On 9/14/2015, Cities Inspection Service, Inc. completed a building inspection of the property located at 123 Oak Street, Someplace, Minnesota for you.
TECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS PROJECT NAME BIBLO PROJECT NUMBER MY11018 Contents Vessel particulars:... 3 Construction:... 3 Hull construction:... 3 Superstructure construction:... 3 Tank construction:... 3
INSPECITON CERTIFICATE
International Register for Classification of Ships Established 1828 - Registre International de Classification de Navires Fondé en 1828.- MARINE DIVISION DIRECTION MARINE No. TPI-TEC08-06/YY/01 INSPECITON
Trouble Shooting. Pump
Trouble Shooting Pump Trouble Possible Cause Remedy Oil leaking in the area of water pump crankshaft Worn crankshaft seal, bad bearing, grooved shaft, or failure of retainer o-ring. Excessive play on crankshaft
BUILDER Custom Line DESIGN Custom Line. LOA 26.10 mt BEAM 6.93 mt. ACCOMODATION 10 + crew (4) HULL Multiaxial fi berglass
BUILDER Custom Line DESIGN Custom Line YEAR 2007 FLAG U.K. LOA 26.10 mt BEAM 6.93 mt DRAFT 2.16 mt DISPLACEMENT 95.2 t ACCOMODATION 10 + crew (4) HULL Multiaxial fi berglass SPEED 12 (16) knt ENGINES 2
Volvo Penta Installation Check List. D4/D6 with IPS Twin Installation (Version 2.4)
D4/D6 with IPS Twin Installation (Version 2.4) Boat/Vessel Manufacturer: Boat/Vessel Model/Type: Engine Installation/Type: Hull Identification Number: Page 1 of 19 1 Check List Information 1.1 Issuer Inspector
Inspecting to a higher standard.
Inspecting to a higher standard. Rob Hopkin Silver Spring, MD 20902 Monday, June 2, 2014 ProTec Inspection Services Inc. 19736 Selby Ave Poolesville, MD 20837 301-972-8531 www.protec-inspections.com [email protected]
SWAN 46 / 421 Sinaida
SWAN 46 / 421 Sinaida Length overall 14.05 m Length of waterline 12.28 m Beam 4.27 m Draft 1.32/3.40 m (daggerboard) Displacement 14.700 kg Ballast 5630 kg Construction material GRP Engine Volvo Penta,
S/Y SEEWIND VAN DER STADT SEAL 36
This is the perfect boat for someone who wants to travel. Seewind is incredibly well set up for a boat of this size. And she is clean and dry and very sturdy. She can sleep up to 7 people and has a watermaker,
CAPRICE 52 FINLAND/STILL CUSTOM
Page 1 CAPRICE LOA: 51 6 / 51.69m Year: 1996 LWL: 42 7 / 12.97m Beam: 13 9 / 4.19m Draft: 6 10 / 2.08m Displacement 14,469kg / 31,900lb (HL): Ballast: 5,488kg / 12,100lb Hull Material: GRP Engine: 1 x
Rustler 43 Motor Yacht. Beautiful Yachts Beautifully Built
Rustler 43 Motor Yacht Beautiful Yachts Beautifully Built 1. GENERAL DIMENSIONS, WEIGHTS & CAPACITIES 2 HULL, DECK AND SUPERSTRUCTURE 3. ACCOMODATION 3.1 Fwd Master Cabin 3.2 Heads & Shower 3.3 Utility
Lancair Legacy Annual Condition Inspection Checklist
Lancair Legacy Annual Condition Inspection Checklist Performed by: Completion Date: Complete Maintenance/Inspection Item Comments Pre-Inspection Research AD and Service bulletins Inspect entire airframe
Chapter 7 Hydraulic System Troubleshooting
Chapter 7 Hydraulic System Troubleshooting General The following troubleshooting information is provided as a general guide to identify, locate and correct problems that may be experienced with the hydraulic
356 CHECKLIST ELECTRICAL: CHASSIS:
356 CHECKLIST ELECTRICAL: Headlights hi/lo beam Taillights Running lights Turn signals Brake lights License light(s) Fog lights Reverse light Horn Dome lights Dash lights Temp guage Tank level guage Tachometer
MOTOR VEHICLE MECHANIC REPAIR CATEGORIES
Chapter 8: Motor Vehicle Mechanic Repair Categories Page 1 CHAPTER 8 MOTOR VEHICLE MECHANIC REPAIR CATEGORIES Section 8-1 REQUIREMENT Section 10 of the Motor Vehicle Service and Repair Act (MCL 257.1310)
LOA: 23' 0" (7.01m) Beam: 8' 6" (2.59m) Max Draft: 1' 6" (0.46m)
24 SPORT CONTENDER Builder: CONTENDER Year Built: 2014 Model: Center Console LOA: 23' 0" (7.01m) Beam: 8' 6" (2.59m) Max Draft: 1' 6" (0.46m) Price: Price On Application Off the market Location: United
Inspection Item COMMENTS
APPENDIX 9 AFFORDABLE HOUSING PROGRAM INSPECTION CHECKLIST Participating Jurisdiction: Homeowner Name: Assisted Property Address: Date of Physical Inspection of Property: Total Square Footage of Property:
BUILDING DEPARTMENT 8748 W. 82 nd Place - Justice, IL 60458 Phone: (708) 458-2130 Fax: (708) 458-3207
BUILDING DEPARTMENT 8748 W. 82 nd Place - Justice, IL 60458 Phone: (708) 458-2130 Fax: (708) 458-3207 SELF EVALUATION CHECKLIST FOR RESIDENTIAL AND MULTI-FAMILY DWELLING INSPECTIONS The attached checklist
Inspections Standard Operating Procedure 5 Aboveground Storage Tanks
Aboveground Storage Tanks Aboveground Storage Tank Inspection This Standard Operating Procedure describes the steps that campus units that manage aboveground oil storage tanks (ASTs) or containers must
TEN HOT TIPS TO PREPARE YOUR BOAT FOR THE COLD WINTER MONTHS
TEN HOT TIPS TO PREPARE YOUR BOAT FOR THE COLD WINTER MONTHS Preparation Will Help Ensure Trouble Free Boating Next Spring, Say Experts at Sierra International It may seem strange, but winter time off
Building Condition Assessment Report
Building Condition Assessment Report Asset C3c - Oak Terrace Cottage 121 Address Riverview Lands, 2601 Lougheed Highway, Coquitlam, BC. V5C 4J2 Construction Year Size (Gross Floor Area) 1920. 2,553 Sq.Ft.
PUMP MAINTENANCE SCHEDULE AND CHECKLISTS
PUMP MAINTENANCE SCHEDULE AND CHECKLISTS Providing a maintenance schedule defined specifically by run hours or yardage pumped serves only as a general guideline given the large amount of variables a unit
Self-Home Inspection Checklist
To be used as a first home visit for note taking. Visit www.homeinspectiondirect.com for more tips and information about buying a home and hiring a home inspector. This form in no way replaces a professional
Preventative Maintenance Plan. Guide. The Simple, Smart Way To Properly Care For Home Systems And Appliances.
Preventative Maintenance Plan Guide The Simple, Smart Way To Properly Care For Home Systems And Appliances. Protect. Prevent. Preserve. Prolong. What AHS Preventative Maintenance Plans Can Do For Your
Notice to all Ship Owners and Operators; Masters, and Deck Officers of Merchant Ships; Manufacturers, and Suppliers of Voyage Data Recorders.
MARINE GUIDANCE NOTE MGN 272 (M) VOYAGE DATA RECORDER S (VDRs) PERFORMANCE TESTING Notice to all Ship Owners and Operators; Masters, and Deck Officers of Merchant Ships; Manufacturers, and Suppliers of
32 Sedan W W W. H A I N E S M A R I N E. C O. U K
W W W. H A I N E S M A R I N E. C O. U K 32 Sedan 32 Sedan HAINES MARINE Unlike mass production builders Haines combine traditional craftsmanship with modern techniques and will tailor a boat to individual
Topics of the Presentation
Drill Rig Safety Topics of the Presentation Personnel safety and monitoring PPE Health (Drugs and Alcohol) Drill Rig operation Safe set up procedures Safe operation of machine Safety related accidents
OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608
Electric Water Heater OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608 If your water Heater is Damaged or you have questions
Oil and Coolant Circulating Heating System. Model - OCSM
Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine
32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw
,1'8675,$/#*(16(7 6HULHV#'9#448 32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw Generator set consisting of engine and alternator mounted
Home Inspection Report
4949 Brownsboro Rd Suite 293 Louisville, KY 40223 (502) 414-1440 [email protected] Inspected By: William Carter, HI-1956 Home Inspection Report Prepared For: Edward Cullen Property Address:
Preparing Your RV for Winter Storage
Did You Know? Facts from America s RV Expert Terry Cooper the Texas RV Professor Preparing Your RV for Winter Storage Well you have decided to let the wheels sit idle for a little while. Below is a checklist
26 3213.13 Diesel Engine Driven Generators Page 1 of 6
Last Update: December 8, 2014 A. Description of System Consultant s Handbook Page 1 of 6 1. Provide a diesel engine driven electric generating unit, factory assembled, tested and certified to operate at
GAS FLAWLESS - FORM C
DESCRIPTION OF THE VESSEL 1. GENERAL 1.1 Builder and Yard HIGAKI S/Y Hull No. H/N 595 1.2 Year built 2007 1.3 Flag MALTA 1.4 Signal Letters and Normal Station Watched 9HVB8 1.5 Classification Lloyds 1.6
Fire Pump Plan Review March 2010
Fire Pump Plan Review March 2010 Date of Review: / / Permit Number: Business/Building Name: Address of Project: Designer Name: Designer s Phone: Contractor: Contractor s Phone: Occupancy Classification:
CLASSIFICATION NOTES
CLASSIFICATION NOTES Type Approval, Installation and Testing of Water Level Detectors on Bulk Carriers and Single Hold Cargo Ships other than Bulk Carriers General Information This edition of the classification
BARRACUDA YACHT DESIGN
BARRACUDA YACHT DESIGN C/ Alfonso Gómez, 9. 28037 Madrid. Spain. Tel +34 91 4400450 Fax: +34 91 4400454 YACHT DESIGNERS & NAVAL ARCHITECTS www.barracuda-yd.com BARRACUDA 105 32m sloop Akalam Designed by
BUYERS GUIDE. IMPORTANT: Spoken promises are difficult to enforce. Ask the dealer to put all promises in writing. Keep this form.
BUYERS GUIDE IMPORTANT: Spoken promises are difficult to enforce. Ask the dealer to put all promises in writing. Keep this form. VEHICLE MAKE MODEL YEAR VIN NUMBER DEALER STOCK NUMBER (Optional) WARRANTIES
POSEIDON ISLA TRAWLERS 1490
POSEIDON ISLA TRAWLERS 1490 GENERAL CHARACTERISTICS AND MAIN MEASURES Loa 14.95 m Lwl 13.40 m Bmax 4.95 m Draught max 1.50 m Depth 2.15 m Full Displacement 30.0 tonnes Certifications : Built to CE certification
Air Conditioner Water Heater - A Product of HotSpot Energy LLC
Air Conditioner Water Heater - A Product of HotSpot Energy LLC PLEASE READ THIS BEFORE YOU INSTALL THE UNIT 1. This air conditioner must be installed and/or repaired by a qualified technician. If you perform
Detainable and ISM Related Deficiencies noted in PSC inspection report of Class NK & NK-SMC ships in April 2015
Summary 1.Fire detection (Smoke detector on bridge deck - Out of order, Failure in the Smoke Detectors of boilers, service generators and lube. Oil pumps, Fire detection system cannot work during inspection,
Guidance for Reducing Port State Detentions. Pre-Port Arrival Quick Reference
Guidance for Reducing Port State Detentions Pre-Port Arrival Quick Reference Our Mission The mission of ABS is to serve the public interest as well as the needs of our members and clients by promoting
External Visual Inspection Form
Tank ID Code Part 1 (a): Information on Registered Facility Name of Registered Facility: Address: Town: Postal Code: Province: Phone Number: Person Conducting the Inspection: Transport Canada Facility
PREVENTION MAINTENANCE CHECKLIST FOR TRACTORS, TRUCKS, AND AUTOMOBILES
PREVENTION MAINTENANCE CHECKLIST FOR TRACTORS, TRUCKS, AND AUTOMOBILES Farm Machinery Fact Sheet FM-21 By Dr. Von H. Jarrett, Extension Agricultural Engineer Systematic sequence for inspection GASOLINE
U.S. Department of Housing and Urban Development Office of Public and Indian Housing. A Good Place to Live!
U.S. Department of Housing and Urban Development Office of Public and Indian Housing A Good Place to Live! Introduction Having a good place to live is important. Through your Public Housing Agency (or
Rail 001 112 2 Canvas, folding top 001 101 3 Rear panel 001 102 4 Stip in window, left 001 106 dto. right 001 107
U 411 1 Rear view mirror, round, metall 13cm Ø 002 045 2 Raised airintake 002 060 3 Side panelling, front, left 002 030 Side panelling, front, right 002 031 4 Panelling left 002 051 dto. right 002 052
GUIDANCE ON DETENTION AND ACTION TAKEN
1. INTRODUCTION 1.1. General GUIDANCE ON DETENTION AND ACTION TAKEN If deficiencies are found the PSCO must: decide on the appropriate action to be taken. be satisfied that they will be rectified. decide
Gianetti Navetta 26 (GRP) Model: Navetta 26. Price: EUR 1,350,000. Number: 3848414. Prestige Yachts Investment - Jean Lacombe
Gianetti Navetta 26 Make: Gianetti Model: Navetta 26 Length: 25.1 m Price: EUR 1,350,000 Year: 2005 Condition: Used Location: Cote D'Azur, France Hull Material: Number of Engines: 2 Fuel Type: Fibreglass
SOLAR PV SYSTEM MAINTENANCE GUIDE
SOLAR PV SYSTEM MAINTENANCE GUIDE GUYANA HINTERLANDS STAND-ALONE SOLAR PV INSTALLATIONS IMPROVING HEALTH FACILITY INFRASTRUCTURE (IHFI) GUYANA CONTRACT NO. EPP-I-00-03-00008-00, TASK ORDER 07 APRIL 2013
Vision Home Inspection
Vision Home Inspection 324 Rams Run Shepherdsville KY 40165-7877 Inspector: James McFadden Property Inspection Report Client(s): Property address: Inspection date: View report summary This report is the
File Number MDRA C20 MANUAL of PROCEDURES for INSPECTION of COMPOSITE AMATEUR-BUILT AIRCRAFT, INSPECTION AND TECHNICAL INFORMATION RECORD
File Number MDRA C20 MANUAL of PROCEDURES for INSPECTION of COMPOSITE AMATEUR-BUILT AIRCRAFT, INSPECTION AND TECHNICAL INFORMATION RECORD GENERAL Section 1.4 FINAL INSPECTION 1. Have all re-inspection
Inspection Report. Dream Home Inspections. www.timinspects.com. 415 Second Ave. Frisco CO 80443-1789 (970) 368-2668
Inspection Report Property Address: 123 Dream Home Way Frisco, CO 80443 Prepared for: Inspector: Tim Nixon Tim Nixon Inspection date: 3/28/2014 1 of 9 General Information Property Information Address:
REGISTRATION OF INTEREST
A B C Adhesives and Sealants Advertising Air Cargo Transport Air Conditioners Air Conditioning Installation or Maintenance or Repair Services Air Filters Ambulance Services Arborist Services Architectural
Flood Rescue Emergency Services First Responders Coast Guard Police
RESCUE RESCUE RESCUE Flood Rescue Emergency Services First Responders Coast Guard Police Sealegs amphibious marine craft give rescue and patrol organizations unique multi-role capabilities which cannot
OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS
Manual No. BLWR043 Rev. 4 September 2012 OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS CVF-8AC CVF-8AC50 CVF-6ACAN CVF-15ACAN CVF-25ACAN CVF-8A15KIT CVF-8A25KIT MODELS: CVF-8DC CVF-6DCAN CVF-15DCAN CVF-25DCAN
T.D. Vinette North Shore Periploi
Make: Model: Length: T.D. Vinette North Shore 34 ft Price: $ 29,900 Year: 1977 Engine Make: Perkins Location: T.D. Vinette North Shore Periploi Alpena, MI, United States Boat Name: Hull Material: Draft:
Hydraulic Trouble Shooting
Hydraulic Trouble Shooting Hydraulic systems can be very simple, such as a hand pump pumping up a small hydraulic jack, or very complex, with several pumps, complex valving, accumulators, and many cylinders
SAILboat 2014 ENGINES, OPTIONS AND NEWS
SAILboat 2014 ENGINES, OPTIONS AND NEWS 2 3 Whether you see sailing as a purely fun and relaxing pastime or as a challenge to conquer sea and wind, you always need to trust your equipment. That is why
DESTROKED. Circuits that will be run through the Ford PCM and Ford Engine Harness
DESTROKED Thank you for your interest in Destroked. Please read through this overview to get a good idea of what is involved in your Cummins conversion project. Circuits that will be run through the Ford
Factory owners must ensure the boiler is:
Factory owners must ensure the boiler is: * Registered with the Boilers and Pressure Vessels Division, Labour Department * Examined by an appointed examiner and has a valid certificate of fitness * Supervised
PROPERTY INSPECTION REPORT
(850) 297-1998 1716 Monticello Dr Tallahassee, Florida 32303 PROPERTY INSPECTION REPORT THIS INSPECTION IS A DETAILED LISTING OF AREAS VISUALLY INSPECTED AT:, Tallahassee FL Client Tallahassee, FL 32304
Volkswagen Jetta, Golf, GTI 1999, 2000 2.8 Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)
17 Engine-Lubrication (Page GR-17) Lubrication system components, removing and installing Oil filter housing, disassembling and assembling Oil pan, removing and installing Oil pressure and oil pressure
Chris Craft Commander
Chris Craft Commander Make: Model: Length: Chris Craft Commander 36 ft Price: $ 35,000 Year: 1973 Engine Make: Ford Location: Cape Coral, FL, United States Hull Material: Draft: Number of Engines: 2 Fuel
SECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS
SECTION 15750 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for roof mounted, self-contained units, with electric cooling, and electric or reverse refrigeration cycle (heat pump) heating
PROPERTY INSPECTION OR ASSESSMENT OF DAMAGES
PROPERTY INSPECTION OR ASSESSMENT OF DAMAGES ADDRESS: 123 MAIN ST MIAMI, FL CLIENT: BUYER ID No: 2014193 DATE: 5/13/2014 INSPECTION OR ASSESSMENT BY: GAIA CONSTRUCTION INC. CGC 1516136 FLORIDA HI-2792
Total Home Inspection Checklist
Total Home Inspection Checklist Use a checklist like this to make sure that you are looking at all parts of the house. Check off those items that are in good condition and make notes about those that are
Technical Guide 08/15/14
Technical Guide 08/15/14 1 Table of Contents Contact information.3 Identifying your system..4-8 Model Number Serial number location Parts of your fuel system..9-14 Fuel pump diagram Wire harness schematics
32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw
,QGXVWULDO#*HQHUDWRU 32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw Generator set consisting of engine and alternator mounted
Jobson THE RIGHT CONTACT
THE RIGHT CONTACT Jobson Italia srl was set up in 1990. The following services are rendered 365 days a year, 24 hours a day: Stocking and trading of spare parts: Main Engines, auxiliary engines, pumps,
MISCELLANEOUS ELECTRICAL JOBS REQUIRING PERMITS
MISCELLANEOUS ELECTRICAL JOBS REQUIRING PERMITS 01. SAFETY INSPECTION of service equipment at FPL Power Source 02. Construction GFI power outlets (Temp Pole for Construction) 03. 90 day temporary power
products 22 º C Ventilation Air Conditioning Refrigeration Energy & Cost Saving Products Inside PROVIDED BY HEINEN & HOPMAN
products > Energy & Cost Saving Products OUTSIDE 35 C HUMIDITY 90% 22 º C Inside PROVIDED BY HEINEN & HOPMAN Heating Ventilation Air Conditioning Refrigeration HVAC energy & COST SAVING POSSIBILITIES A
Finding and Fixing Leaks
Finding and Fixing Leaks Where did all that water go? Could we have splashed all that water out of the tub? These are all common thoughts that can run through your mind when you open up the hot tub cover
Kobelco Extended Warranty Program. www.kobelco-europe.com
Kobelco Extended Warranty Program www.kobelco-europe.com Kobelco Extended Warranty is a convenient, value added way to give your Kobelco customers added security and peace of mind. Benefits of the Kobelco
BELZONA KNOW-HOW VALVES, PIPES AND FITTINGS BELZONA VPF SYSTEM SELECTOR BELZONA KNOW-HOW FOR VALVES, PIPES AND FITTINGS
KNOW-HOW FOR THE REPAIR, RENOVATION AND RECLAMATION OF VALVES, PIPES AND FITTINGS B E L Z O N A V P F VPF SYSTEM SELECTOR FOR VALVES, PIPES AND FITTINGS SYSTEM Belzona VPF-1 Belzona VPF-2 Belzona VPF-3