Cisco Catalyst 6500/6800 Instant Access Fundamentals

Size: px
Start display at page:

Download "Cisco Catalyst 6500/6800 Instant Access Fundamentals"

Transcription

1 Cisco Catalyst 6500/6800 Instant Access Fundamentals Vivek Baveja Technical Marketing Engineer August 28, 2013

2 Catalyst Instant Access Abstract Abstract Cisco Catalyst Instant Access brings fabric extension technology (similar to Data Center FEX) with operational simplicity to the Campus Catalyst Ethernet switching line tailor made to needs of campus/enterprise network deployments. It creates a single network touch point and single configuration across distribution and access layer switches, ultimately driving simplified operations, distribution layer (Catalyst 6500/6800) features at access layer, consistent CLI and lower total cost of ownership (TCO). This session will focus on Instant Access (IA) overview and value proposition, components, features, scale, packet walks, configuration and CLI look and feel, and Instant Access provisioning details. 2

3 Session Objectives At the end of this session participants should understand: Solution Overview, Value proposition, Components of Instant Access solution Internal Architecture of the solution including packet walks. Features and Functionality. Configuration, CLI Look and feel and how to provision Instant Access Solution. 3

4 Presentation Legend Reference Material Standalone Multilayer Switch Virtual Switching System Layer 2 Link Layer 3 Link Fabric Link Catalyst Instant Access 4

5 Catalyst Instant Access Fundamentals Agenda Solution Overview Architectural Details Features Recommended Topologies Configurations and Provisioning Key Takeaways 5

6 Cisco Catalyst Instant Access Standalone VSS Instant Access LACP or PAGP LACP or PAGP VSL LACP or PAGP VSL SDP SRP SCP Access Switch Access Switch Access Switch Access Switch Benefits of Instant Access mplifies Operations via ngle Point of Management, Configuration, Troubleshooting across Distribution & Access Block Catalyst 6500 features at Access Instant Access Client Instant Access Client Consistent Features and Agile Infrastructure across Access layer 6

7 Traditional L2 or L3 Campus Core 94 Total Devices for Image and Configuration Management 168 Access Trunks/Port-Channels 4032 User Ports Considerations: STP Loop Prevention FHRP Tuning CAM/ARP Tuning PIM Tuning/DR priority Routing Protocol Tuning Building 1 Building 2 Building 3 Building 4 94 Separate Configurations of SNMP, NTP, TACACS, Banner, vty, VLAN DB, Mgmt IP/GW, Hostname 7

8 Traditional L2 or L3 Campus with Stacking Core 34 Total Devices for Image and Configuration Management 48 Access Trunks/Port-Channels 4032 User Ports Considerations: STP Loop Prevention FHRP Tuning CAM/ARP Tuning PIM Tuning/DR priority Routing Protocol Tuning Building 1 Building 2 Building 3 Building 4 34 Separate Configurations of SNMP, NTP, TACACS, Banner, vty, VLAN DB, Mgmt IP/GW, Hostname 9

9 VSS Campus with Stacking VSS Core 29 Total Devices for Image and Configuration Management 48 Access Trunks/Port-Channels 4032 User Ports Considerations: STP Loop Prevention FHRP Tuning CAM/ARP Tuning PIM Tuning/DR priority Routing Protocol Tuning Building 1 Building 2 Building 3 Building 4 29 Separate Configurations of SNMP, NTP, TACACS, Banner, vty, VLAN DB, Mgmt IP/GW, Hostname 10

10 Catalyst Instant Access Instant Access Core 5 Total Devices for Image and Configuration Management Automated Trunk Configuration 4032 User Ports Considerations: STP Loop Prevention FHRP Tuning CAM/ARP Tuning PIM Tuning/DR priority Routing Protocol Tuning Building 1 Building 2 Building 3 Building 4 5 Separate Configurations of SNMP, NTP, TACACS, Banner, vty, VLAN DB, Mgmt IP/GW, Hostname 11

11 Catalyst Instant Access Instant Access Core NO Trunks to Configure from Access to Distribution NO Routing Protocols or Spanning-Tree configuration between Access and Distribution NO Configuration or Image Management at Access Building 1 Building 2 Building 3 Building 4 5 Total Devices for Image and Configuration Management Automated Trunk Configuration 4032 User Ports Considerations: STP Loop Prevention FHRP Tuning CAM/ARP Tuning PIM Tuning/DR priority Routing Protocol Tuning 5 Separate Configurations of SNMP, NTP, TACACS, Banner, vty, VLAN DB, Mgmt IP/GW, Hostname 12

12 Catalyst Instant Access Operational mplicity REDUCED TCO ISE Cisco Prime Managed Devices = 20+ Managed Devices = 1 Benefits ngle Point Of Management, Configuration and Troubleshooting Consistent Features at Access 1000 Port Campus Distribution POD Highly Fault Tolerance with Quad- Sup-VSS SSO Agile Infrastructure to add new features uniformly across Access Layer A ngle Image to deploy and manage across Distribution POD 14

13 Distributed Wired Centralized Wired Unified Access Architecture Unified Access One Cisco Prime Management Infrastructure Cisco ISE One Policy Centralized Wireless Distributed Wired and Wireless VSS VSS MA MA MA Traditional Campus Instant Access Campus One Network Wired & Wireless Converged Access

14 Catalyst Instant Access Solution Overview Key Takeaways ngle Point of Management for Distribution Block, One point of Management for 23 Switches (1008 Ports-Phase1) No Configuration at Access Layer No Image Management at Access Layer No STP and Routing Protocols between Access and Distribution Consistent Features at Access with single Image across Traditional Architecture, Converged Access and Instant Access co-exist 16

15 Catalyst Instant Access Fundamentals Agenda Solution Overview Architecture Components Control Plane Data Plane Features Recommended Topologies Configurations and Provisioning Key Takeaways 17

16 Cisco Catalyst Instant Access Components X x10G Virtual Switching System (VSS) X x10G Supervisor 2T Supervisor 2T IA Parent FEX-Fabric IA Client 18

17 Cisco Catalyst Instant Access Components X x10G Catalyst 6500E Catalyst 6807-XL Virtual Switching System (VSS) X x10G Supervisor 2T Catalyst 6880-X Supervisor 2T IA Parent FEX-Fabric IA Client 19

18 Catalyst Instant Access Components ngle Switch VSS Mode ngle Cat6500 Switch configured in VSS Mode switch virtual domain 100 switch mode virtual ngle Switch in VSS Mode as IA Parent Cat6500-VSS#show switch virtual slot-map Virtual Slot to Remote Switch/Physical Slot Mapping Table: Virtual Remote Physical Module Slot No Switch No Slot No Uptime w3d w3d :19:22 20

19 Cisco Catalyst Instant Access Parent Catalyst 6500 Supervisor 2T The Supervisor 2T (hardware & software features) is designed to Scale and Perform in the Core & Distribution Layers 256K - 1M FIB Entries Up to 16K Bridge Domains Up to 128K Logical Interfaces Up to 16K VRF instances Up to 128K IPv4/v6 Multicast routes Native VPLS in Hardware 512K - 1M Flexible Netflow Entries (FnF) SGT & SGACL for Cisco Trustsec (CTS) L2+L3+L4 ACL Support Improved CoPP in Hardware Per-protocol (LIF) Interface Statistics and more 21

20 WS-X G/10G/1G 16 ports SFP+ 10GE (with FourX) Supports integrated DFC4 / DFC4XL Supports VNTAG on all ports Support VSL on all ports Port 5,6, 7,8 Port 13,14, 15,16 CVR-4SFP10G FourX Port 9,10, 11,12 Port 17,18, 19,20 16 x 10G SFP+ adapter (FourX) SFP+ SR, LR, LRM and ER Optics 24

21 Catalyst Instant Access Client: 6848ia Two options: 48 Ports GigE PoE+, 48 Ports GigE 2 x 10G uplink SFP+ Ports Stackable up to 3 clients at FCS 80Gbps Bidirectional Stack Bandwidth ngle Fixed Power Supply and Fixed Fans Operates in Client Mode ONLY Full PoE (15W) across 48 ports Full PoE+ (30W) across 24 ports Includes Stack Module, no licensing required 26

22 Catalyst Instant Access Components Summary X x10G Virtual Switching System (VSS) X x10G Supervisor 2T Supervisor 2T IA Parent FEX-Fabric IA Client 27

23 Catalyst Instant Access Fundamentals Agenda Solution Overview Architecture Components Control Plane Data Plane Features Recommended Topologies Configurations and Provisioning Key Takeaways

24 Catalyst Instant Access Control Plane Behind the Scene 1. 1 Switch Discovery Protocol (SDP) Fabric Link Discovery switchport mode Fex-fabric Switch Discovery Fex associate <Fex-ID> EtherChannel Link Aggregation 2. 2 Switch Registration Protocol (SRP) Exchange Compatibility information IA Client Registration IA Client image management IA Client OIR Stack Member Identification & mgmt 3. 3 Switch Configuration Protocol Configuration Status Statistics 4 4. Inter Card Communication (ICC) for Syslog, QoS, Remote login. 3 Configuration Interface Stats 4 Remote Login Syslog QoS No User Configuration All Magically Happens in background Instantly Instant Access Parent Client ID Image Check VIF ID 29

25 Catalyst Instant Access Fundamentals Agenda Solution Overview Architecture Components Control Plane Data Plane Features Recommended Topologies Configurations and Provisioning Key Takeaways

26 Catalyst Instant Access Data Plane Components Instant Access Parent IA Control Plane IA Client VIF association VNTAG Assignment IA Data Plane MAC Learning and Switching L2 & L3 Features Instant Access Parent IA Client Switch VNTAG Encapsulation QoS 32

27 VNTAG 802.1Qbh Unicast D=1 Unicast to FEX Host Port Multicast P=1 Pointer to Multicast Table on FEX Client DA[6] SA[6] VNTAG[6] 802.1Q[4] Frame Payload. CRC[4] VNTAG ETHER TYPE (0X8926) D[1] P[1] DVIF [12] L[1] R[1] R[1] R[1] SVIF[12] Destination VIF Source VIF Destination bit Pointer bit (multicast) Loopback bit Reserved 33

28 Catalyst Instant Access Local Processing of Remote Ports, How? Ingress Mapping TAG IA Client Interface IA Parent VIF 1 IF 1 VIF 2 IF 2 (VIF 1 ) (VIF 2 ) Automatically assigned One VIF to each host port One VIF to each Etherchannel One VIF to FEX CPU for Control Channel IA Parent VIF = 0 Multicast/Broadcast: Pointer to Replication Table in IA Client F101 Switch-3 IF 1 IF 2 Host-1 Host-2 IA Client Hosts TAG: Virtual NIC Tag VIF Virtual Interface 34

29 Catalyst Instant Access Packet Walk (IA Client Host Port to IA Parent) MAC + Payload IA Parent VNTAG SVIF = VIF 1 DVIF = 0 MAC + Payload VNTAG SVIF = VIF 1 DVIF = 0 MAC + Payload IF 1 (VIF 1 ) F101 Switch-3 IA Client Host-1 MAC + Payload VNTAG: Virtual NIC Tag VIF Virtual Interface 35

30 Catalyst Instant Access Packet Walk (IA Parent to IA Client Host Port) MAC + Payload VNTAG SVIF = 0, DVIF = VIF 1 IA Parent MAC + Payload VNTAG SVIF = 0, DVIF = VIF 1 MAC + Payload F101 Switch-3 IA Client IF 1 (VIF 1 ) MAC + Payload Host-1 VNTAG: Virtual NIC Tag VIF Virtual Interface 36

31 Catalyst Instant Access Packet Walk (Host 1 to Host 2) SA=MAC1, DA=MAC2+ Payload SA=MAC1, DA=MAC2+ Payload VNTAG SVIF = VIF 1 DVIF = 0 VNTAG SVIF = 0, DVIF = VIF 2 SA=MAC1, DA=MAC2+ Payload SA=MAC1, DA=MAC2+ Payload VNTAG SVIF = VIF 1 DVIF = 0 SA=MAC1, DA=MAC2+ Payload IF 1 (VIF 1 ) F101 Switch-3 IF 2 (VIF 2 ) VNTAG SVIF = 0, DVIF = VIF 2 SA=MAC1, DA=MAC2+ Payload SA=MAC1, DA=MAC2+ Payload Host-1 MAC1 Host-2 MAC2 SA=MAC1, DA=MAC2+ Payload VNTAG: Cisco Virtual Public NIC Tag 37

32 Catalyst Instant Access Packet Walk - Multicast / Broadcast , Incoming Interface: FortyGig 5/1 RPF Neighbor Outgoing interface list: Gigabitethernet 101/1/0/1, Forward/Dense, 0:57:31/0:02:52 Gigabitethernet 101/1/0/2, Forward/Dense, 0:56:55/0:01:28 MAC + Payload VNTAG, P=1 SVIF =0, DVIF = Group VIF MAC + Payload F101 Switch-3 IF 1 IF 2 (VIF 1 ) (VIF 2 ) IA Parent Group VIF Outgoing Interface IA Client IF1, IF2 MAC + Payload Host-1 Host-2 MAC + Payload Hosts VNTAG: Virtual NIC Tag VIF Virtual Interface 38

33 Catalyst Instant Access Architecture Key Takeaways Components Cat6500E & Cat6800 Series Supervisor 2T VSS WS-X G/10G/1G Catalyst Instant Access Client 6848ia Automatic Discovery (SDP), Registration (SRP) and Configuration (SCP) of IA Client VNTag encapsulation of packets on Fabric links between IA Parent and IA Client Local Multicast/Broadcast replication at IA Client 41

34 Catalyst Instant Access Fundamentals Agenda Solution Overview Architecture Features mplicity of Provisioning & Image Management mplification of Configuration QoS Capabilities High Availability Recommended Topologies Configurations and Provisioning Key Takeaways 42

35 Catalyst Instant Access mplicity of Provisioning Automatic-Provisioning on Connection A Client gets automatically discovered and provisioned using IA Control Protocol when connected. Automatic Discovery and Stack Member by Parent via Stack Master F 110 F 111 Pre-Provisioning Provision IA Client and interface Configurations before even physically connecting the IA Client mod provision create fex 111 type C6800IA-48FPD mod provision create fex 111 module 2 type C6800IA-TD 43

36 New Deployment of Instant Access mplicity of Image Management Across Distribution Block One IOS Image across Distribution / Access Block Cat6500 Image and Cat6800ia Image Bundled together as one Image. IA Client image is like a Line card image on Cat6k. Automatic Image Management at Access. Enhanced Fast Software Upgrade(eFSU) supported for Instant Access Rolling Upgrade for each FEX-ID Just Like a Line Card, The Cat6848ia image is managed by VSS System 44

37 New Deployment of Instant Access Automatic Image Provisioning IA Client Image bundled w/ Cat6k. (like a Line card image) VSS Cat6500-VSS#dir microcode: Directory of microcode:/ 0 dr-- <no size> <no date> 1 -r <no date> C2LC 2 -r <no date> C4LC 3 -r <no date> TRIFECTA 4 -r <no date> FEX_C2K 5 -r <no date> LCP_LX r <no date> LCP_LX1000 IF { IA Parent Image version IA Client image version } THEN {Client Upgrade to New Image by IA Parent automatically} Stacking: Stack Master ensures all stack members have correct images efsu Rolling Upgrades: Ability to upgrade IA Clients after ISSU Run Version on Standby slot issu runversion [fex[range] <num all >] 45

38 Catalyst Instant Access Fundamentals Agenda Solution Overview Architecture Features mplicity of Provisioning & Image Management mplification of Configuration QoS Capabilities High Availability Recommended Topologies Configurations and Provisioning Key Takeaways

39 Configuration mplicity Interface Numbering & ngle point of management L2, Trunk Port Fex Fabric interface gig 115/1/0/1 interface gig 115/1/0/2... interface gig 115/1/0/48! interface gig 116/1/0/1 interface gig 116/1/0/48... interface gig 116/2/0/1... interface gig 116/3/0/48 F 115 F 116 interface gig 0/1 interface gig 0/2... interface gig 0/48 interface gig 0/1 interface gig 0/2... interface gig 0/48 47

40 Catalyst Instant Access Features Cat6500 Features at Access Summary Category Switching Layer-2 IPv6 Instant Access POE, POE+, MEC, FlexStack Etherchannel, PAgP, LLDP, STP, GRE Tunneling, MPLS, MPLS-VPN IPv6 First Hop Security, Multicast Routing, QoS, Stateless Auto Config, Layer-3 PBR, EVN, VRF-Lite, PIM SM, WCCPv2, Inter VLAN Routing, ECMP, L3 Routing protocols Security QoS Medianet 802.1x Guest VLAN, ACL, SXP, SGT, SGACL, IP Source Guard, DHCP Snooping, VACL, RACL, PACL, FnF Policing, Marking, Rate Limiting, SRR Mediatrace, Perf-Monitoring 48

41 VLAN 10 Configuration mplicity L2 Across Distribution- Configuration VLAN 110 Configuration done once at Distribution only, No Configuration at Access Layer Hostname B2F2S2 Vlan 10 Hostname B2F2S2 Vlan 110 Vlan 20 Hostname B2F2S2 Vlan 1021 Vlan 120 Vlan 30 Hostname B2F2S2 Desc Mgmt Vlan 1021 Vlan 130 Vlan 40 Ip address Desc Mgmt Vlan 1021 Vlan ! Ip address Desc Mgmt Vlan 1021 interface! Ip address Desc Mgmt Port-channel5 switchport interface trunk Port-channel5! Ip address allowed vlan 10,110 switchport switchport mode trunk trunk allowed interface vlan Port-channel5! 20,120 Interface switchport range TenGigabitEthernet1/2/5-6 mode trunk switchport trunk interface allowed Port-channel5 vlan 30,130 channel-group Interface 4 range mode on TenGigabitEthernet1/2/5-6 switchport mode switchport trunk trunk allowed vlan channel-group 4 mode Interface on range switchport TenGigabitEthernet1/2/5-6 mode trunk channel-group Interface 4 mode on range TenGigabitEthernet1/2/5-6 channel-group 4 mode on VLAN 20 VLAN 120 VLAN 30 L2 Trunk VLAN 130 VLAN 40 VLAN 140 F 116 VLAN 10 VLAN 110 VLAN 30 VLAN 130 F 115 VLAN 10 VLAN 110 VLAN 20 VLAN 120 Vlan 10 Vlan 40 Vlan 110 Vlan 140 VLAN 120 Vlan Desc Mgmt VLAN 140 Ip address ! Interface Port-channel4 Fex associate 104 Switchport mode fex-fabric interface Port-channel Fabric 9 links Fex associate 109 Switchport mode fex-fabric! Interface range Gig 116/1/0/1-24, F /1/0/1-24 Switchport F mode 113 access Span-tree port fast Swichport VLAN 30 access VLAN vlan 10 VLAN 40 VLAN VLAN VLAN 40 Interface gig 1/1> Interface gig 1/3> Interface gig 1/4> Interface gig 1/5> Switchport mode Switchport access mode access Switchport mode access Switchport mode access Switchport access Switchport vlan 10 access vlan 20 Switchport access vlan30 Switchport access vlan40 Span-tree portfast Span-tree portfast Span-tree portfast Span-tree portfast Interface gig 1/2> Interface gig 1/2> Interface gig 1/2> Interface gig 1/2> Switchport mode Switchport access mode access Switchport mode access Switchport mode access Switchport access Switchport vlan 110 access vlan 120 Switchport access vlan Switchport 130 access vlan 140 Span-tree portfast Span-tree portfast Span-tree portfast Span-tree portfast 50

42 Configuration mplicity Flexibility of L2 Across Distribution IA Clients at Access with L2 Broadcast domain across Distribution VLAN 10 VLAN 110 VLAN 20 VLAN 120 VLAN 200 VLAN 30 VLAN 130 VLAN 40 VLAN 140 VLAN 10 VLAN 30 VLAN 110 VLAN 110 Fabric links Fabric links F 116 F 115 F 113 F 114 F 116 F 115 F 113 F 114 VLAN 10 VLAN 110 VLAN 20 VLAN 120 VLAN 30 VLAN 130 VLAN 40 VLAN 140 VLAN 10 VLAN 30 VLAN 110 VLAN 110 VLAN

43 Catalyst Instant Access Fundamentals Agenda Solution Overview Architecture Features mplicity of Provisioning & Image Management mplification of Configuration QoS Capabilities High Availability Recommended Topologies Configurations and Provisioning Key Takeaways

44 IA Client Fabric Link Subscription Ratios VSS Pair at Distribution IA Client Non Stacked VSS VSS Pair at Distribution IA Client Stacked VSS F101 F102 F103 Stack of 3 F101 F102 F IA Client Host Ports Two 10G Fex-Fabric links (MEC) to VSS Pair 2.4 : 1 Subscription Ratio 144 IA Client Host Ports Two 10G Fabric link (MEC) to VSS Pair 7.2: 1 Subscription Ratio Recommended Design 53

45 IA Client Fabric Link Subscription Ratios IA Parent nge Switch VSS Mode IA Client Non Stacked IA Parent ngle Switch VSS Mode IA Client Stacked F101 F102 F103 3 member F101 F102 F103 stack 48 IA Host Ports One 10G Fabric Link 4.8 : 1 Subscription Ratio 144 IA Host Ports One 10G Fabric link 14.4 : 1 Subscription Ratio Not Recommended Design Reduced Redundancy and Lower Bandwidth with ngle Uplinks 54

46 Catalyst Instant Access QoS IA Client Fabric Link IA Parent Trust DSCP/COS 4 Queues on Host Ports downstream 4 Queues on Fabric Upstream DSCP/COS Queue Map Classification Marking/Remarking Policing Aggregate Microflow 8 Queues Downlink Shaping & Queuing on Fabric Link not supported 56

47 Catalyst Instant Access QoS Ingress IA Client Host Port Over Fabric Link. IA Client Fabric Link IA Parent Data Data BPDU COS 5 COS 3 IA Control Traffic Queues (1P3Q3T) Priority (1) Standard Q (2) Standard Q (3) Standard Q (4) Trust DSCP at IA Host Port DSCP/COS to Output Q Map 1 Priority Queue 3 Standard Queue Shared Queue Marking/Re-Marking at IA Parent Policing at IA Parent 57

48 Catalyst Instant Access QoS Egress IA Parent to IA Client over Fabric Link IA Client Fabric Link IA Parent Trust DSCP/COS Map Table at IA Parent Dscp-outputq-threshold map: DSCP = d1d2 d1 :d : : : : : : DSCP 40: d1 = 4, d2 = 0 6 : DSCP 16: d1 = 1, d2 = 6 Queues 1P7Q4T Priority (1) Standard Q (2) Standard Q (3) Standard Q (4) Standard Q (5) Standard Q (6) Standard Q (7) IA Control Traffic Data Data BPDU DSCP 40 DSCP 16 58

49 Catalyst Instant Access QoS Egress IA Client Host Ports IA Client Fabric Link IA Parent Queues (1P3Q3T) Priority (1) Standard Q (2) Standard Q (3) Standard Q (4) Data Data DSCP 40 DSCP 16 Queues 1P7Q4T Priority (1) Standard Q (2) Standard Q (3) Standard Q (4) Trust DSCP/COS 1P3QT3 Egress Host Port Shared Standard Q (5) Standard Q (6) Standard Q (7) 59

50 IA Client Port QOS with Fabric Link EtherChannels To Network VSS F101 ngle FEX Intf Multiple Physical paths End User Traffic From Network VSS F101 End User Traffic End user traffic for FEX port Gig 102/1/0/48 IA Client Default load balance: src-mac IA Parent Default load balance: src-dst-ip Global load-balance changes applied to IA Client module as well. IA Client port : Service Policies applied Controller distributes policies to all Fabric links Ingress and Egress policies Policy Statistics Aggregated by Controller 60

51 EtherChannel Load Balance at IA Parent Both ends of the FEX fabric Etherchannel will use the same port-channel distribution algorithm, to the extent this is supported by the FEX hardware. Cat6500-VSS(config)#port-channel load-balance? dst-ip Dst IP Addr dst-mac Dst Mac Addr dst-mixed-ip-port Dst IP Addr and TCP/UDP Port dst-port Dst TCP/UDP Port mpls Load Balancing for MPLS packets src-dst-ip Src XOR Dst IP Addr IA Client Port Channel Load Balance Hash src-dst-mac Src XOR Dst Mac Addr dst-ip Dst IP Addr src-dst-mixed-ip-port Src XOR Dst IP Addr and TCP/UDP Port dst-mac Dst Mac Addr src-dst-port Src XOR Dst TCP/UDP Port src-dst-ip Src XOR Dst IP Addr src-ip Src IP Addr src-dst-mac Src XOR Dst Mac Addr src-mac Src Mac Addr src-ip Src IP Addr src-mixed-ip-port Src IP Addr and TCP/UDP Port src-mac Src Mac Addr src-port Src TCP/UDP Port vlan-dst-ip Vlan, Dst IP Addr vlan-dst-mixed-ip-port Vlan, Dst IP Addr and TCP/UDP Port vlan-src-dst-ip Vlan, Src XOR Dst IP Addr vlan-src-dst-mixed-ip-port Vlan, Src XOR Dst IP Addr and TCP/UDP Port vlan-src-ip Vlan, Src IP Addr vlan-src-mixed-ip-port Vlan, Src IP Addr and TCP/UDP Port 61

52 Catalyst Instant Access Fundamentals Agenda Solution Overview Architecture Features mplicity of Provisioning & Image Management mplification of Configuration QoS Capabilities High Availability Recommended Topologies Configurations and Provisioning Key Takeaways

53 Catalyst Instant Access High Availability. L3 Fabric F 113 F 114 VSS / VSS Quad-Sup SSO EtherChannel Load Balancing Up to 6 10G in MEC Bundle Load Sharing Ca6k Hash Algorithms Up to 3 Stack Members 80G stack bandwidth between stack members EtherChannel Across Stack Members Up to 6 10G into One EtherChannels Dual Active detection on fabric links Upto 8 Host Port Etherchannels Host Port EtherChannel Across Stack Members Master Failure will not reset Etherchannel 63

54 Instant Access: VSS Dual Active Detection Enhanced PAgP Enhanced SDP (Fabric Link Discovery Protocol) Switch 1 Switch 2 Switch 1 Switch 2 Active Hot Standby Active Hot Standby Requires epagp capable neighbor : 3750: 12.2(46)SE 4500: 12.2(44)SE 6500: 12.2(33)SXH1 Sub-second convergence Cat6500-VSS#show fex dual-active FEX dual-active detection enabled: Yes Requires esdp Neighbor: Catalyst 6800ia: 15.1(2)SY Channel Group 16 (FEX 132) Dual Active detection capable: Yes switch 1 member port state: Te1/2/5 - Interface Up. state: bound Sub-second convergence Te1/2/13 - Interface Up. state: bound switch 2 member port state: Te2/2/5 - Interface Up. state: bound SDP Satellite Cisco Discover Public Protocol Te2/2/13 - Interface Up. state: bound 64 64

55 Catalyst Instant Access EFSU A = Active S=Standby LC=Line Card Old Code Newer Code A LC1 LC2 LC3 S LC1 LC2 LC3 issu load version A LC1 LC2 LC3 S LC1 LC2 LC3 issu run version S LC1 LC2 LC3 A LC1 LC2 LC3 issu run version fex 103 S A 101 F 102 F 103 F 101 F 102 F 103 F 101 F 102 F 103 LC1 LC1 LC2 LC2 LC3 LC3 S LC1 LC2 LC3 A LC1 LC2 LC3 issu commit version S LC1 LC2 LC3 A LC1 LC2 LC3 issu accept version S LC1 LC2 LC3 A LC1 LC2 LC3 F 101 F 102 F 103 issu run version fex 102, 101 F 101 F 102 F 103 F 101 F 102 F 103 F 101 F 102 F 103 Rolling upgrade across FEX-ID s 65

56 Catalyst Instant Access Capabilities Key Takeaways Auto Provisioning and Pre-Provisioning Support ngle Image across Distribution Block ngle Configuration for Distribution Block Catalyst 6500 Features at Access EFSU for IA Clients 67

57 Catalyst Instant Access Fundamentals Agenda Solution Overview Architecture Features Recommended Topologies Distribution VSS Stacking IDF Scenarios Fabric Link Connectivity Host Port Etherchannel Configurations and Provisioning Key Takeaways ACCESS DISTRIBUTION 68

58 Catalyst Instant Access VSS Pair as IA Parent Recommended Recommended ngle Switch VSS Mode VSS Pair VSS Quad-Sup SSO ngle Cat6500 Switch configured in VSS Mode with One Active and One Standby Supervisor FEX ID is mapped to a Virtual Slot High Availability with a Supervisor in each Chassis. MEC across VSS Pair HA with 2 Supervisors in each chassis in SSO Mode Hyper High Availability 69

59 Catalyst Instant Access Fundamentals Agenda Solution Overview Architecture Key Capabilities Recommended Topologies Distribution VSS Stacking IDF Scenarios Fabric Link Connectivity Host Port Etherchannel Configurations and Provisioning Key Takeaways ACCESS DISTRIBUTION 70

60 Catalyst Instant Access Phase 1 Scalability Maximum Client Node User Ports 1008 Maximum FEX ID s 12 Maximum Client Switches 21 Client Node ID is a single client or a stack. If using individual clients max of 12 switches supported. Maximum Clients in Stack 3 Maximum User Ports in Stack 144 Most optimum where IDF has 96 or greater ngle Client IDF s support fewer overall ports # of IDFs # of Ports/IDF # of Clients in a Stack # of Access Ports

61 Catalyst Instant Access (Phase 1) Stacking Scenario s Stack of 3 (Phase 1) Max FEX-ID 12 7 Nodes of 144 ports each = 1008 FEX 101 FEX 102 FEX 103 FEX 104 FEX 105 FEX 106 FEX Nodes of 96 ports each + 1 Node of 48 port = 1008 FEX 101 FEX 102 FEX 103 FEX 104 FEX 105 FEX 106 FEX 107 FEX 108 FEX 109 FEX 110 FEX

62 Catalyst Instant Access (Phase 1) Stacking Scenario s Stack of 3 (Phase 1) Max FEX-ID Nodes of 48 ports each = 576 ports FEX 101 FEX 102 FEX 103 FEX 104 FEX 105 FEX 106 FEX 107 FEX 108 FEX 109 FEX 110 FEX 111 FEX 112 Max 21 Stacks Switches = 1008 ports. FEX 101 FEX 102 FEX 103 FEX 104 FEX 105 FEX 106 FEX 107 FEX 108 FEX

63 Catalyst Instant Access Fundamentals Agenda Solution Overview Architecture Key Capabilities Recommended Topologies Distribution VSS Stacking IDF Scenarios Fabric Link Connectivity Host Port Etherchannel Configurations and Provisioning Key Takeaways ACCESS DISTRIBUTION

64 Catalyst Instant Access Fabric Link Connectivity Scenarios Dual Homed to VSS Pair Recommended Design Dual Homed to VSS Pair Dual Homed across Stack Members Up to 6 uplinks(60g) MEC across Client to Parent 75

65 Catalyst Instant Access Fabric Link Connectivity Scenarios ngle Homed to VSS Pair Possible but Not Recommended ngle homed to VSS pair ngle Homed upto 6 links in MEC Across Stack members 76

66 Catalyst Instant Access Fabric Link Connectivity Scenarios ngle Switch VSS Mode Possible but Not Recommended ngle Homed to Switch 1 in VSS mode Dual Homed to ngle Switch in VSS mode Up to 6 links in MEC homed to ngle Switch in VSS Mode 77

67 Catalyst Instant Access Fundamentals Agenda Solution Overview Architecture Key Capabilities Recommended Topologies Distribution VSS Stacking IDF Scenarios Fabric Link Connectivity Host Port Etherchannel Configurations and Provisioning Key Takeaways ACCESS DISTRIBUTION

68 Catalyst Instant Access Host Port Connectivity Options. (Supported FCS +) Host ngle Homed End devices to IA Client dual homed to VSS Pair MEC at IA Ports across Stack Members 79

69 Catalyst Instant Access Recommended Topologies Key Takeaways VSS Pair at Distribution 21 Switches in Stacked mode to achieve 1008 port scale Upto 6 MEC (60Gbps) across from Stack to IA Parent Fabric Link MEC across Stack Members Host Port Ether Channel across Stack Members Host Port EtherChannel across FEX Stacks (FEX-ID) not supported. 82

70 Catalyst Instant Access Fundamentals Agenda Solution Overview Architecture Features Recommended Topologies Configuration and Provisioning Provisioning of IA CLI look and Feel: Configuration, Verification & Troubleshooting Key Takeaways

71 Catalyst Instant Access Cat6500 VSS Configuration Switch 1 Configuration redundancy mode sso! switch virtual domain 100 switch 1! interface Port-channel1 switch virtual link 1 interface ten 1/5/4 channel-group 1 mode on interface ten 1/1/1 channel-group 1 mode on! switch convert mode virtual Switch 1 Switch 2 Cat6500-VSS#show switch virtual Switch mode VSS Verification Virtual switch domain number : 100 Local switch number : 1 VSS Configurations Guide talyst6500/ios/12.2sx/configuration/guide/vss.ht ml Switch 2 Configuration redundancy mode sso! : Virtual Switch switch virtual domain 100 Switch 2 Local switch operational role: Virtual Switch Active Peer switch number : 2 Peer switch operational role : Virtual Switch Standby! interface Port-channel2 switch virtual link 2 interface ten 2/5/4 Channel-group 2 mode on interface ten 2/1/1 channel-group 2 mode on! switch convert mode virtual 84

72 Catalyst Instant Access ngle Switch VSS Mode Switch 1 Configuration redundancy mode sso! switch virtual domain 100 switch 1! switch convert mode virtual Switch 1 VSS Configurations Guide 85

73 Catalyst Instant Access Provisioning Automatic Discovery of IA Client. Step 1 interface Port-channel20 switchport switchport mode fex-fabric fex associate 118 Step 2 interface range TenGig1/2/5, TenGig2/2/5 switchport channel-group 20 mode on The Discovery process starts automatically once the FEX-Fabric is configured on downlinks to IA Client No Console Access Required to Instant Access Client Provisioning 87

74 Catalyst Instant Access Provisioning Automatic Discovery and Provisioning of IA Client Cat6500-VSS#show fex 118 detail FEX: 118 Description: FEX0118 state: online FEX version: 15.0(2.0.51)UCP Extender Model: WS-C2960X-48FPD-L, Extender Serial: FHH1707P00S FCP ready: yes Image Version Check: overridden Fabric Portchannel Ports: 2 Fabric port for control traffic: Te1/2/5 Fabric interface state: Po20 - Interface Up. Te1/2/5 - Interface Up. state: bound Te2/2/5 - Interface Up. state: bound Cat6500-VSS#show run fex 118 Current configuration : bytes! interface GigabitEthernet118/1/0/1 88

75 Catalyst Instant Access Provisioning Pre-Provisioning of IA Client Pre-Provisioning Switch and host port configuration before the IA Switch is physically connected can be done very similar to a line card Pre Provisioning Pre-Provisioning of IA Client Cat6500-VSS#mod provision create fex 121 type C6800IA-48FPD FEX 121 slot 1 module provisioning entry added. Pre-Provisioning a Stack Member to Existing FEX-ID Cat6500-VSS#mod provision create fex 121 type C6800IA-48FPD slot 2 FEX 121 slot 2 module provisioning entry added. Cat6500-VSS#show switch virtual slot-map Virtual Slot to Remote Switch/Physical Slot Mapping Table: Virtual Remote Physical Module Slot No Switch No Slot No Uptime

76 Catalyst Instant Access Provisioning Pre Provisioning of Host Port Configuration Once the FEX-ID is provisioned, the Host Port Interface can be configured like Any regular interface in Cat6500 Cat6500-VSS#show run fex 121 Building configuration... Current configuration : 5564 bytes! interface GigabitEthernet121/1/0/1 switchport mode access... FEX 121 Pre Provision any IA Client Host Port like a regular port ahead. Cat6500-VSS#conf t Enter configuration commands, one per line. End with CNTL/Z. Cat6500-VSS(config)#int Gig 121/1/0/24 Cat6500-VSS(config-if)#description To Printer Bldg3,4th Floor. Cat6500-VSS(config-if)#switchport access vlan

77 Catalyst Instant Access Provisioning mplicity of adding a Stack Member Plug and Play Cat6500-VSS#show mod fex 118 Switch Number: 118 Role: FEX Mod Ports Card Type Model Serial No C6800IA 48GFPwr 2SFP Fullers_48FullPwr FHH1707P00S Cat6500-VSS# *Apr 3 19:37:58.026: %SATMGR -SW1-5-FEX_MODULE_ONLINE: FEX 118, module 2 online Cat6500-VSS# *Apr 3 19:37:58.030: %OIR-SW1-6-INSREM: Switch 118 Physical Slot 2 - Module Type LINE_CARD inserted Fex 118 Module 2: Passed Online Diagnostics *Apr 3 19:38:12.178: %OIR-SW1-6-SP_INSCARD: Card inserted in Switch_number = 118, physical slot 2, interfaces are now online Cat6500-VSS#show mod fex 118 Switch Number: 118 Role: FEX Mod Ports Card Type Model Serial No C6800IA 48GFPwr 2SFP Fullers_48FullPwr FHH1707P00S 2 48 C6800IA 48GFPwr 2SFP Fullers_48FullPwr FHH1707P010 Stack Member automatically Discovered and associated to FEX like a Line Card 91

78 Catalyst Instant Access Provisioning mplicity of Adding Additional Uplinks Cat6500-VSS#show fex 118 detail FEX: 118 Description: FEX0118 state: online <Snip> Fabric Portchannel Ports: 2 Fabric port for control traffic: Te1/2/5 Fabric interface state: Po20 - Interface Up. Te1/2/5 - Interface Up. state: bound Te2/2/5 - Interface Up. state: bound Cat6500-VSS(config)#int range TenGig1/2/13, TenGig2/2/13 Cat6500-VSS(config-if-range)#channel-group 20 mode on Cat6500-VSS#show fex 118 detail FEX: 118 Description: FEX0118 state: online <Snip> Fabric Portchannel Ports: 4 Fabric port for control traffic: Te1/2/5 Fabric interface state: Po20 - Interface Up. Te1/2/5 - Interface Up. state: bound Te1/2/13 - Interface Up. state: bound Te2/2/5 - Interface Up. state: bound Te2/2/13 - Interface Up Cisco state: and/or its bound affiliates. All rights reserved. Just Bundling to fex-fabric Port Channel on Parent, No Configuration at IA Client 92

79 Catalyst Instant Access Fundamentals Agenda Solution Overview Architecture Features Recommended Topologies Configuration and Provisioning Provisioning of IA CLI look and Feel: Configuration, Verification & Troubleshooting Key Takeaways

80 Catalyst Instant Access Host Port: Interface Naming Convention <Interface-type>/<fex-id>/<module>/<submode>/<port> FEX ID Stack Sub Module FEX Port interface GigabitEthernet 118/1/0/1 interface GigabitEthernet 118/2/0/1 94

81 CLI Look and Feel Configuration Ease Interface range command Cat6500-VSS(config)#int range Gig 132/1/0/1-48, Gig132/2/0/1-48 Cat6500-VSS(config-if-range)# Show run for IA Client Cat6500-VSS#show run fex 132 Building configuration... Current configuration : bytes! interface GigabitEthernet132/1/0/1 switchport access vlan 10! interface GigabitEthernet132/1/0/2 switchport access vlan 10 95

82 CLI Look and Feel Location Check FEX Status, Hardware Details, Location Cat6500-VSS#show fex FEX FEX FEX FEX Number Description State Model Serial Bldg-3-Conf-R online WS-C2960X-48FPD-L FHH1707P02S 132 BLDG 3 IDF 2. online WS-C2960X-48FPD-L FHH1707P03S Cat6500-VSS(config)#fex 132 Cat6500-VSS(config-fex)#location? additional-location-information Set additional location, CA Type 22 civic-location-id Civic location information custom-location-id Custom location information geo-location-id Geo location information Cat6500-VSS(config-if)#location civic-location-id fex port-location? 96

83 CLI Look and Feel Verification Check FEX Status, Hardware Details, Location for specific FEX-ID, Fabric Links State. Cat6500-VSS#show fex 118 FEX: 118 Description: Bldg-3-Conf-Rm state: online FEX version: 15.0(2.0.51)UCP Extender Model: WS-C6800ia-48FPD-L, Extender Serial: FHH1707P00S FCP ready: no Image Version Check: overridden Fabric Portchannel Ports: 2 Fabric port for control traffic: Te2/2/5 Fabric interface state: Po12 - Interface Up. Te1/2/5 - Interface Up. state: bound Te2/2/5 - Interface Up. state: bound Cat6500-VSS#show interface fex-fabric Fabric Fabric Port FEX FEX FEX Port State Uplink Model Serial Te1/2/5 bound 0 WS -C6800ia-48FPD-L FHH1707P00S 117 Te1/2/13 bound 1 WS -C6800ia-48FPD-L FHH1707P01S 132 Te2/2/5 bound 0 WS -C6800ia-48FPD-L FHH1707P00S 118 Te2/2/13 bound 1 WS -C6800ia-48FPD-L FHH1707P03S 97

84 CLI Look and Feel Verification and Troubleshooting Cat6500-VSS#show module fex Switch Number: 132 Role: FEX Mod Ports Card Type Model Serial No C6800IA 48GFPwr 2SFP Fullers_48FullPwr FHH1707P00S 2 48 C6800IA 48GFPwr 2SFP Fullers_48FullPwr FHH1707P010 Cat6500-VSS#show environment status fex all Fex 132 Fan 1 FEX 132 Fan 1 type: FEX 132 Fan 1 mode: Auto Fex 132 fan-tray 1 fan-fail: OK Fex 132 Fan 2 FEX 132 Fan 2 type: FEX 132 Fan 2 mode: Auto Fex 132 fan-tray 2 fan-fail: OK FEX 132 module 1 cooling requirement: 84 cfm FEX 132 module 2 cooling requirement: 84 cfm Fex 132 module 1 outlet temperature: 45C Fex 132 module 2 outlet temperature: 2013 Cisco and/or 52C its affiliates. All rights reserved. 98

85 CLI Look and Feel Host Port details Cat6500-VSS#show int gig 132/1/0/1 GigabitEthernet132/1/0/1 is up, line protocol is up (connected) Hardware is C6k 1000Mb 802.3, address is 0022.bdf (bia 0022.bdf4.6601) MTU 1500 bytes, BW Kbit, DLY 10 usec, reliability 255/255, txload 1/255, rxload 1/255 Encapsulation ARPA, loopback not set Show interface Gig 132/1/0/1? Keepalive set (10 sec) Full-duplex, 1000Mb/s, media type is 10/100/1000BaseT accounting input flow-control is off, output flow-control is unsupported Counters Clock mode is auto description ARP type: ARPA, ARP Timeout 04:00:00 history Last input never, output never, output hang never Last clearing of "show interface" counters 1d17h precedence Input queue: 0/2000/0/0 (size/max/drops/flushes); Total output status drops: 0 Queueing strategy: fifo summary Output queue: 0/40 (size/max) 5 minute input rate 0 bits/sec, 0 packets/sec Transceiver 5 minute output rate 1000 bits/sec, 1 packets/sec users 0 packets input, 0 bytes, 0 no buffer Vlan Received 0 broadcasts (0 multicasts) 0 runts, 0 giants, 0 throttles... 0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored 0 watchdog, 0 multicast, 0 pause input 99

86 CLI Look and Feel Troubleshooting Fabric UpLinks from IA Client Cat6500-VSS#attach fex Open To troubleshoot on IA Client Uplink - interface stats, transceiver details- Attach to IA Client attach <fex-id> FEX-132# FEX-132#show int tengigabitethernet 1/0/1 TenGigabitEthernet1/0/1 is up, line protocol is up (connected) Hardware is Ten Gigabit Ethernet, address is 0022.bdf (bia 0022.bdf4.6633) MTU 9198 bytes, BW Kbit/sec, DLY 10 usec, reliability 255/255, txload 1/255, rxload 1/255 Encapsulation ARPA, loopback not set Keepalive not set Full-duplex, 10Gb/s, link type is auto, media type is SFP-10GBase-SR input flow-control is off, output flow-control is unsupported ARP type: ARPA, ARP Timeout 04:00:00 Last input never, output never, output hang never Last clearing of "show interface" counters never Input queue: 0/75/0/0 (size/max/drops/flushes); Total output drops: 0 Queueing strategy: fifo Output queue: 0/40 (size/max) 5 minute input rate 4000 bits/sec, 3 packets/sec 5 minute output rate 0 bits/sec, 0 packets/sec packets input, bytes, 0 no buffer 100

87 CLI Look and Feel Troubleshooting Fabric Up Links from IA Client FEX-132#show int ten 1/0/2 transceiver ITU Channel not available (Wavelength not available), Transceiver is internally calibrated. If device is externally calibrated, only calibrated values are printed. ++ : high alarm, + : high warning, - : low warning, -- : low alarm. NA or N/A: not applicable, Tx: transmit, Rx: receive. ma: milliamperes, dbm: decibels (milliwatts). Optical Optical Temperature Voltage Tx Power Rx Power Port (Celsius) (Volts) (dbm) (dbm) Te1/0/

88 Key Takeaways. Benefits ngle Point of Management mplified Operations Feature Consistency at Access Layer Components Cat 6500E / C Sup2T VSS/ VSS Quad-Sup SSO + X G mode, Cat6848ia Supports SR, LR, ER 10G SFP+ optics Configurations Consistent w/ Data Center FEX CLI Features Stacking, POE/POE+, All Cat6500 features available at Access Layer Layer 2, Layer 3, IPv6, MPLS, Centralized Application Visibility and Control w/ Flexible NetFlow, mplified Network Security, 2013 Cisco and/or Network its affiliates. All Virtualization rights reserved. deployment. 102

89 Cisco Catalyst Instant Access Summary mplified Configuration and Deployment ngle point of Management Plug and Play Provisioning No Image Management at Access Cat6500 Features consistent across Distribution and Access mplifying Networks Reducing TCO 103

90 Thank You

91 Comparison to Nexus FEX 105

Configuring the Switch for the Firewall Services Module

Configuring the Switch for the Firewall Services Module CHAPTER 2 Configuring the Switch for the Firewall Services Module This chapter describes how to configure the Catalyst 6500 series switch or the Cisco 7600 series router for use with the FWSM. Before completing

More information

- EtherChannel - Port Aggregation

- EtherChannel - Port Aggregation 1 Port Aggregation - EtherChannel - A network will often span across multiple switches. Trunk ports are usually used to connect switches together. There are two issues with using only a single physical

More information

Configuring Link Aggregation

Configuring Link Aggregation 10 CHAPTER This chapter describes how to configure link aggregation for the ML-Series cards, both EtherChannel and packet-over-sonet/sdh (POS) channel. For additional information about the Cisco IOS commands

More information

6/8/2011. Document ID: 12023. Contents. Introduction. Prerequisites. Requirements. Components Used. Conventions. Introduction

6/8/2011. Document ID: 12023. Contents. Introduction. Prerequisites. Requirements. Components Used. Conventions. Introduction Page 1 of 9 Products & Services Understanding EtherChannel Load Balancing and Redundancy on Catalyst Switches Document ID: 12023 Contents Introduction Prerequisites Requirements Components Used Conventions

More information

Configuring EtherChannels

Configuring EtherChannels CHAPTER 12 This chapter describes how to configure EtherChannels on the Cisco 7600 series router Layer 2 or Layer 3 LAN ports. For complete syntax and usage information for the commands used in this chapter,

More information

How To Balance On A Cisco Catalyst Switch With The Etherchannel On A Fast Ipv2 (Powerline) On A Microsoft Ipv1 (Powergen) On An Ipv3 (Powergadget) On Ipv4

How To Balance On A Cisco Catalyst Switch With The Etherchannel On A Fast Ipv2 (Powerline) On A Microsoft Ipv1 (Powergen) On An Ipv3 (Powergadget) On Ipv4 Cisco - Understanding EtherChannel Load Balancing and Redundancy on Catalyst Switch...Page 1 of 10 Understanding EtherChannel Load Balancing and Redundancy on Catalyst Switches Document ID: 12023 Contents

More information

Cisco Integrators Cisco Partners installing and implementing the Cisco Catalyst 6500 Series Switches

Cisco Integrators Cisco Partners installing and implementing the Cisco Catalyst 6500 Series Switches Implementing Cisco Catalyst 6500 Series Switches (RSCAT6K) Fast Lane is proud to be once again on the cutting edge with this intensive 3-day Authorized course on the latest features and functionality of

More information

Migrate from Cisco Catalyst 6500 Series Switches to Cisco Nexus 9000 Series Switches

Migrate from Cisco Catalyst 6500 Series Switches to Cisco Nexus 9000 Series Switches Migration Guide Migrate from Cisco Catalyst 6500 Series Switches to Cisco Nexus 9000 Series Switches Migration Guide November 2013 2013 Cisco and/or its affiliates. All rights reserved. This document is

More information

Catalyst update & Local Manufactory

Catalyst update & Local Manufactory Catalyst update & Local Manufactory Agenda Unified Access Catalyst 2960 (PLUS / S / SF / X / XR) Catalyst 3560X / 3650 / 3750X / 3850 Catalyst 4500 Catalyst 6800 Fabricação nacional Cisco EnergyWise Cisco

More information

Chapter 2 Lab 2-2, Configuring EtherChannel Instructor Version

Chapter 2 Lab 2-2, Configuring EtherChannel Instructor Version Chapter 2 Lab 2-2, Configuring EtherChannel Instructor Version Topology Objective Background Configure EtherChannel. Four switches have just been installed. The distribution layer switches are Catalyst

More information

Configuring IPS High Bandwidth Using EtherChannel Load Balancing

Configuring IPS High Bandwidth Using EtherChannel Load Balancing Configuring IPS High Bandwidth Using EtherChannel Load Balancing This guide helps you to understand and deploy the high bandwidth features available with IPS v5.1 when used in conjunction with the EtherChannel

More information

Cisco Catalyst 4500-X Series Switch Family

Cisco Catalyst 4500-X Series Switch Family Product Bulletin Cisco Catalyst 4500-X Series Fixed 10 Gigabit Ethernet Aggregation Switch PB696811 Overview Cisco Catalyst 4500-X Series Switch (Figure 1) is a fixed aggregation switch that delivers best-in-class

More information

Virtual PortChannel Quick Configuration Guide

Virtual PortChannel Quick Configuration Guide Virtual PortChannel Quick Configuration Guide Overview A virtual PortChannel (vpc) allows links that are physically connected to two different Cisco Nexus 5000 Series devices to appear as a single PortChannel

More information

CT5760 Controller and Catalyst 3850 Switch Configuration Example

CT5760 Controller and Catalyst 3850 Switch Configuration Example CT5760 Controller and Catalyst 3850 Switch Configuration Example Document ID: 116342 Contributed by Antoine KMEID and Serge Yasmine, Cisco TAC Engineers. Aug 13, 2013 Contents Introduction Prerequisites

More information

Configuring InterVLAN Routing and ISL/802.1Q Trunking on Catalyst 2900XL/3500XL/2940/2950/2970 Series Switches Using an External Router

Configuring InterVLAN Routing and ISL/802.1Q Trunking on Catalyst 2900XL/3500XL/2940/2950/2970 Series Switches Using an External Router Configuring InterVLAN Routing and ISL/802.1Q Trunking on Catalyst 2900XL/3500XL/2940/2950/2970 Series Switches Using an External Router Document ID: 14976 Introduction Before You Begin Conventions Prerequisites

More information

How To Set Up A Virtual Network On Vsphere 5.0.5.2 (Vsphere) On A 2Nd Generation Vmkernel (Vklan) On An Ipv5 Vklan (Vmklan)

How To Set Up A Virtual Network On Vsphere 5.0.5.2 (Vsphere) On A 2Nd Generation Vmkernel (Vklan) On An Ipv5 Vklan (Vmklan) Best Practices for Virtual Networking Karim Elatov Technical Support Engineer, GSS 2009 VMware Inc. All rights reserved Agenda Best Practices for Virtual Networking Virtual Network Overview vswitch Configurations

More information

Alexander Paul [email protected] IBM Certified Advanced Technical Expert (C.A.T.E.) for Power Systems Certified Cisco Systems Instructor CCSI #32044

Alexander Paul paulalex@de.ibm.com IBM Certified Advanced Technical Expert (C.A.T.E.) for Power Systems Certified Cisco Systems Instructor CCSI #32044 Network Virtualization Deep dive and Network Troubleshooting in a virtualized Environment Alexander Paul [email protected] IBM Certified Advanced Technical Expert (C.A.T.E.) for Power Systems Certified

More information

20 GE + 4 GE Combo SFP + 2 10G Slots L3 Managed Stackable Switch

20 GE + 4 GE Combo SFP + 2 10G Slots L3 Managed Stackable Switch GTL-2691 Version: 1 Modules are to be ordered separately. 20 GE + 4 GE Combo SFP + 2 10G Slots L3 Managed Stackable Switch The LevelOne GEL-2691 is a Layer 3 Managed switch with 24 x 1000Base-T ports associated

More information

> Avaya / Cisco Interoperability Technical Configuration Guide. Ethernet Routing Switch

> Avaya / Cisco Interoperability Technical Configuration Guide. Ethernet Routing Switch Ethernet Routing Switch IP Phones Engineering > Avaya Data Solutions Document Date: April 6, 2010 Document Number: NN48500-588 Document Version: 2.0 Abstract The purpose of this TCG is to show some of

More information

Chapter 3. Enterprise Campus Network Design

Chapter 3. Enterprise Campus Network Design Chapter 3 Enterprise Campus Network Design 1 Overview The network foundation hosting these technologies for an emerging enterprise should be efficient, highly available, scalable, and manageable. This

More information

IMPLEMENTING CISCO SWITCHED NETWORKS V2.0 (SWITCH)

IMPLEMENTING CISCO SWITCHED NETWORKS V2.0 (SWITCH) IMPLEMENTING CISCO SWITCHED NETWORKS V2.0 (SWITCH) COURSE OVERVIEW: Implementing Cisco Switched Networks (SWITCH) v2.0 is a five-day instructor-led training course developed to help students prepare for

More information

VSS-Enabled Campus Best Practice Configuration Example

VSS-Enabled Campus Best Practice Configuration Example APPENDIXA VSS-Enabled Campus Best Practice Configuration Example Figure A-1 illustrates the baseline best practice configuration required to set up basic VSS enabled network. The circle indicates the essential

More information

Feature Support Cisco 2960 Cisco 2960S Brocade ICX 6450 Brocade ICX 6430 1 GE SFP, 2 10GE SFP+, 4 1GE SFP, 2 DUAL PURPOSE PORTS, 1GE OR SFP

Feature Support Cisco 2960 Cisco 2960S Brocade ICX 6450 Brocade ICX 6430 1 GE SFP, 2 10GE SFP+, 4 1GE SFP, 2 DUAL PURPOSE PORTS, 1GE OR SFP Feature Support Cisco 2960 Cisco 2960S Brocade ICX 6450 Brocade ICX 6430 Uplinks 1 GE SFP, 2 10GE SFP+, 4 1GE SFP, 2 DUAL PURPOSE PORTS, 1GE OR SFP 40G Stack bandwidth via std 10G ports 2x10G* Fiber aggregation

More information

Configuring EtherChannels

Configuring EtherChannels 25 CHAPTER This chapter describes how to configure EtherChannel interfaces. For complete syntax and usage information for the commands used in this chapter, refer to the Catalyst 2950 Desktop Switch Command

More information

Chapter 4: Spanning Tree Design Guidelines for Cisco NX-OS Software and Virtual PortChannels

Chapter 4: Spanning Tree Design Guidelines for Cisco NX-OS Software and Virtual PortChannels Design Guide Chapter 4: Spanning Tree Design Guidelines for Cisco NX-OS Software and Virtual PortChannels 2012 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.

More information

Configuring EtherChannel and 802.1Q Trunking Between Catalyst L2 Fixed Configuration Switches and Catalyst Switches Running CatOS

Configuring EtherChannel and 802.1Q Trunking Between Catalyst L2 Fixed Configuration Switches and Catalyst Switches Running CatOS Configuring EtherChannel and 802.1Q Trunking Between Catalyst L2 Fixed Configuration Switches and Catalyst Switches Running CatOS Document ID: 23408 Contents Introduction Prerequisites Requirements Components

More information

Application Note Gigabit Ethernet Port Modes

Application Note Gigabit Ethernet Port Modes Application Note Gigabit Ethernet Port Modes Application Note Gigabit Ethernet Port Modes Table of Contents Description... 3 Benefits... 4 Theory of Operation... 4 Interaction with Other Features... 7

More information

TP-LINK. JetStream 28-Port Gigabit Stackable L3 Managed Switch. Overview. Datasheet T3700G-28TQ. www.tp-link.com

TP-LINK. JetStream 28-Port Gigabit Stackable L3 Managed Switch. Overview. Datasheet T3700G-28TQ. www.tp-link.com TP-LINK JetStream 28-Port Gigabit Stackable L3 Managed Switch Overview TP-LINK s is an L3 managed switch designed to build a highly accessible, scalable, and robust network. The switch is equipped with

More information

- Switch Port Configuration -

- Switch Port Configuration - 1 Cisco Operating Systems - Switch Port Configuration - Cisco offers two brands of network switches: Catalyst Cisco s flagship switching platform, with a large selection of models spanning access, distribution,

More information

RESILIENT NETWORK DESIGN

RESILIENT NETWORK DESIGN Matěj Grégr RESILIENT NETWORK DESIGN 1/36 2011 Brno University of Technology, Faculty of Information Technology, Matěj Grégr, [email protected] Campus Best Practices - Resilient network design Campus

More information

Virtual Private LAN Service on Cisco Catalyst 6500/6800 Supervisor Engine 2T

Virtual Private LAN Service on Cisco Catalyst 6500/6800 Supervisor Engine 2T White Paper Virtual Private LAN Service on Cisco Catalyst 6500/6800 Supervisor Engine 2T Introduction to Virtual Private LAN Service The Cisco Catalyst 6500/6800 Series Supervisor Engine 2T supports virtual

More information

EX 3500 ETHERNET SWITCH

EX 3500 ETHERNET SWITCH PRODUCT SPEC SHEET EX 3500 ETHERNET SWITCH EX 3500 ETHERNET SWITCH EQUIPPED THE WIRED ETHERNET SWITCH FOR UNIFIED WIRED-WIRELESS NETWORKS GET ALL THE WIRED NETWORKING FEATURES YOU NEED, PLUS THE SIMPLICITY

More information

LINK AGGREGATION INTEROPERABILITY OF THE DELL POWERCONNECT 6200 SERIES

LINK AGGREGATION INTEROPERABILITY OF THE DELL POWERCONNECT 6200 SERIES LINK AGGREGATION INTEROPERABILITY OF THE DELL POWERCONNECT 6200 SERIES WITH CISCO IOS OR CISCO CATOS BASED SWITCHES By Bruce Holmes CONTENTS INTRODUCTION 3 LINK AGGREGATION WITH GIGABIT ETHERNET CISCO

More information

Configuring LACP (802.3ad) Between a Catalyst 6500/6000 and a Catalyst 4500/4000

Configuring LACP (802.3ad) Between a Catalyst 6500/6000 and a Catalyst 4500/4000 Configuring LACP (802.3ad) Between a Catalyst 6500/6000 and a Catalyst 4500/4000 Document ID: 19642 Contents Introduction Before You Begin Conventions Prerequisites Components Used Background Theory Difference

More information

Implementing Cisco Data Center Unified Fabric Course DCUFI v5.0; 5 Days, Instructor-led

Implementing Cisco Data Center Unified Fabric Course DCUFI v5.0; 5 Days, Instructor-led Implementing Cisco Data Center Unified Fabric Course DCUFI v5.0; 5 Days, Instructor-led Course Description The Implementing Cisco Data Center Unified Fabric (DCUFI) v5.0 is a five-day instructor-led training

More information

Configuring Flexible NetFlow

Configuring Flexible NetFlow CHAPTER 62 Note Flexible NetFlow is only supported on Supervisor Engine 7-E, Supervisor Engine 7L-E, and Catalyst 4500X. Flow is defined as a unique set of key fields attributes, which might include fields

More information

Cisco IOS Software Release 15.0(1)SY1 New Features and Hardware Support

Cisco IOS Software Release 15.0(1)SY1 New Features and Hardware Support Product Bulletin Cisco IOS Software Release 15.0(1)SY1 New Features and Hardware Support PB696622 Cisco IOS Software Release 15.0(1)SY1 supports Cisco Catalyst 6500 Series Supervisor Engine 2T only. Release

More information

Using MLAG in Dell Networks

Using MLAG in Dell Networks dd version Using MLAG in Dell Networks A deployment guide for Dell Networking switches (version ) Dell Engineering March 04 January 04 A Dell Deployment and Configuration Guide Revisions Date Description

More information

How To Switch In Sonicos Enhanced 5.7.7 (Sonicwall) On A 2400Mmi 2400Mm2 (Solarwall Nametra) (Soulwall 2400Mm1) (Network) (

How To Switch In Sonicos Enhanced 5.7.7 (Sonicwall) On A 2400Mmi 2400Mm2 (Solarwall Nametra) (Soulwall 2400Mm1) (Network) ( You can read the recommendations in the user, the technical or the installation for SONICWALL SWITCHING NSA 2400MX IN SONICOS ENHANCED 5.7. You'll find the answers to all your questions on the SONICWALL

More information

Lab Testing Summary Report

Lab Testing Summary Report Lab Testing Summary Report January 2015 Report SR140730F Product Category: Supervisor Engine Vendor Tested: Product Tested: Catalyst 4500E Supervisor Engine 8-E Key findings and conclusions: Tests achieved

More information

High Performance 10Gigabit Ethernet Switch

High Performance 10Gigabit Ethernet Switch BDCOM S3900 Switch High Performance 10Gigabit Ethernet Switch BDCOM S3900 is a standard L3 congestion-less switch series, which are capable of multi-layer switching and wire-speed route forwarding. Its

More information

Cisco 7600 Series Routers Cisco 7600 Series: Ethernet Services 20G Line Cards for Carrier Ethernet

Cisco 7600 Series Routers Cisco 7600 Series: Ethernet Services 20G Line Cards for Carrier Ethernet . Data Sheet Cisco 7600 Series Routers Cisco 7600 Series: Ethernet Services 20G Line Cards for Carrier Ethernet The Cisco 7600 Series Ethernet Services 20 Gbps (ES20) Line Cards utilize an extensible design

More information

Cisco Certified Network Associate Exam. Operation of IP Data Networks. LAN Switching Technologies. IP addressing (IPv4 / IPv6)

Cisco Certified Network Associate Exam. Operation of IP Data Networks. LAN Switching Technologies. IP addressing (IPv4 / IPv6) Cisco Certified Network Associate Exam Exam Number 200-120 CCNA Associated Certifications CCNA Routing and Switching Operation of IP Data Networks Operation of IP Data Networks Recognize the purpose and

More information

Lab 7-1 Configuring Switches for IP Telephony Support

Lab 7-1 Configuring Switches for IP Telephony Support Lab 7-1 Configuring Switches for IP Telephony Support Learning Objectives Configure auto QoS to support IP phones Configure CoS override for data frames Configure the distribution layer to trust access

More information

INDIAN INSTITUTE OF TECHNOLOGY BOMBAY MATERIALS MANAGEMENT DIVISION : (+91 22) 2576 8800 (DR)

INDIAN INSTITUTE OF TECHNOLOGY BOMBAY MATERIALS MANAGEMENT DIVISION : (+91 22) 2576 8800 (DR) Item CORE SWITCH: 24 Ports Item Description 1)General requirements: Switch- modular operating system, non-blocking wire speed performance. Switch solution-capable of providing complete redundancy by using

More information

Configuring NetFlow-lite

Configuring NetFlow-lite CHAPTER 55 Note NetFlow-lite is only supported on Catalyst 4948E Ethernet Switch. This chapter describes how to configure NetFlow-lite on the Catalyst 4948E switch. NetFlow-lite provides traffic monitoring

More information

20 GE PoE-Plus + 4 GE PoE-Plus Combo SFP + 2 GE SFP L2 Managed Switch, 370W

20 GE PoE-Plus + 4 GE PoE-Plus Combo SFP + 2 GE SFP L2 Managed Switch, 370W GEP-2672 Version: 1 20 GE PoE-Plus + 4 GE PoE-Plus Combo SFP + 2 GE SFP L2 Managed Switch, 370W The LevelOne GEP-2672 is a Layer 2 Managed switch with 24 x 1000Base-T PoE-Plus ports associated with 4 x

More information

How To Configure Link Aggregation On Supermicro Switch 2 And 3 (Lan) On A Microsoft Vlan 2 And Vlan 3 (Vlan) (Lan 2) (Vlans) (Lummer) (Powerline) (

How To Configure Link Aggregation On Supermicro Switch 2 And 3 (Lan) On A Microsoft Vlan 2 And Vlan 3 (Vlan) (Lan 2) (Vlans) (Lummer) (Powerline) ( L2 / L3 Switches Link Aggregation Configuration Guide Revision 1.0 The information in this USER S MANUAL has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility

More information

Link Aggregation Interoperability of the Dell PowerConnect 5316M with Cisco IOS or Cisco CatOS based Switches. By Bruce Holmes

Link Aggregation Interoperability of the Dell PowerConnect 5316M with Cisco IOS or Cisco CatOS based Switches. By Bruce Holmes Link Aggregation Interoperability of the Dell PowerConnect 5316M with Cisco IOS or Cisco CatOS based Switches By Bruce Holmes August 2005 Contents Introduction...3 Link Aggregation with Gigabit Ethernet

More information

Expert Reference Series of White Papers. VMware vsphere Distributed Switches

Expert Reference Series of White Papers. VMware vsphere Distributed Switches Expert Reference Series of White Papers VMware vsphere Distributed Switches [email protected] www.globalknowledge.net VMware vsphere Distributed Switches Rebecca Fitzhugh, VCAP-DCA, VCAP-DCD, VCAP-CIA,

More information

Chapter 7 Lab 7-1, Configuring Switches for IP Telephony Support

Chapter 7 Lab 7-1, Configuring Switches for IP Telephony Support Chapter 7 Lab 7-1, Configuring Switches for IP Telephony Support Topology Objectives Background Configure auto QoS to support IP phones. Configure CoS override for data frames. Configure the distribution

More information

Network Virtualization with the Cisco Catalyst 6500/6800 Supervisor Engine 2T

Network Virtualization with the Cisco Catalyst 6500/6800 Supervisor Engine 2T White Paper Network Virtualization with the Cisco Catalyst 6500/6800 Supervisor Engine 2T Introduction Network virtualization is a cost-efficient way to provide traffic separation. A virtualized network

More information

DCS-3950-52C Fast Ethernet Intelligent Access Switch Datasheet

DCS-3950-52C Fast Ethernet Intelligent Access Switch Datasheet DCS-3950-52C Fast Ethernet Intelligent Access Switch Datasheet DCS-3950-52C Product Overview DCS-3950-52C switch is Fast Ethernet intelligent security access switch for carrier and MAN networks. It supports

More information

48 GE PoE-Plus + 2 GE SFP L2 Managed Switch, 375W

48 GE PoE-Plus + 2 GE SFP L2 Managed Switch, 375W GEP-5070 Version: 1 48 GE PoE-Plus + 2 GE SFP L2 Managed Switch, 375W The LevelOne GEP-5070 is an intelligent L2 Managed Switch with 48 x 1000Base-T PoE-Plus ports and 2 x 100/1000BASE-X SFP (Small Form

More information

Configure IOS Catalyst Switches to Connect Cisco IP Phones Configuration Example

Configure IOS Catalyst Switches to Connect Cisco IP Phones Configuration Example Configure IOS Catalyst Switches to Connect Cisco IP Phones Configuration Example Document ID: 69632 Introduction Prerequisites Requirements Components Used Conventions Background Information Configure

More information

"Charting the Course...

Charting the Course... Description "Charting the Course... Course Summary Interconnecting Cisco Networking Devices: Accelerated (CCNAX), is a course consisting of ICND1 and ICND2 content in its entirety, but with the content

More information

Layer 3 Network + Dedicated Internet Connectivity

Layer 3 Network + Dedicated Internet Connectivity Layer 3 Network + Dedicated Internet Connectivity Client: One of the IT Departments in a Northern State Customer's requirement: The customer wanted to establish CAN connectivity (Campus Area Network) for

More information

DCS-3950-28CT-POE fully loaded AT PoE Switch Datasheet

DCS-3950-28CT-POE fully loaded AT PoE Switch Datasheet DCS-3950-28CT-POE fully loaded AT PoE Switch Datasheet DCS-3950-28CT-POE Product Overview DCS-3950-28CT-POE is fully loaded PoE switch for carrier and enterprises. It supports comprehensive QoS, enhanced

More information

How To Learn Cisco Cisco Ios And Cisco Vlan

How To Learn Cisco Cisco Ios And Cisco Vlan Interconnecting Cisco Networking Devices: Accelerated Course CCNAX v2.0; 5 Days, Instructor-led Course Description Interconnecting Cisco Networking Devices: Accelerated (CCNAX) v2.0 is a 60-hour instructor-led

More information

Course Contents CCNP (CISco certified network professional)

Course Contents CCNP (CISco certified network professional) Course Contents CCNP (CISco certified network professional) CCNP Route (642-902) EIGRP Chapter: EIGRP Overview and Neighbor Relationships EIGRP Neighborships Neighborship over WANs EIGRP Topology, Routes,

More information

Analysis of Basic Quality of Service Mechanism for Voice over IP In Hamdard University Network Campus

Analysis of Basic Quality of Service Mechanism for Voice over IP In Hamdard University Network Campus Analysis of Basic Quality of Service Mechanism for Voice over IP In Hamdard University Network Campus Shahbaz Akhatar Siddiqui Student MS (Telecom) Hamdard University Karachi Junior Lecturer in National

More information

CCNA R&S: Introduction to Networks. Chapter 5: Ethernet

CCNA R&S: Introduction to Networks. Chapter 5: Ethernet CCNA R&S: Introduction to Networks Chapter 5: Ethernet 5.0.1.1 Introduction The OSI physical layer provides the means to transport the bits that make up a data link layer frame across the network media.

More information

PA-MC-T3 Multi-Channel T3 Synchronous Serial Port Adapter Enhancement

PA-MC-T3 Multi-Channel T3 Synchronous Serial Port Adapter Enhancement PA-MC-T3 Multi-Channel T3 Synchronous Serial Port Adapter Enhancement This feature module describes the PA-MC-T3 Multi-Channel T3 port adapter (PA-MC-T3 [=]), which can now be configured as either customer

More information

NX-OS and Cisco Nexus Switching

NX-OS and Cisco Nexus Switching NX-OS and Cisco Nexus Switching Next-Generation Data Center Architectures Kevin Corbin, CCIE No. 11577 Ron Fuller, CCIE No. 5851 David Jansen, CCIE No. 5952 Cisco Press 800 East 96th Street Indianapolis,

More information

40 Gigabit Ethernet on Cisco Catalyst 6500 Series Switches: How It Works

40 Gigabit Ethernet on Cisco Catalyst 6500 Series Switches: How It Works White Paper 40 Gigabit Ethernet on Cisco Catalyst 6500 Series Switches: How It Works Sridhar Subramanian, Technical Marketing Engineer, Cisco Shawn Wargo, Technical Marketing Engineer, Cisco White Paper

More information

Link Aggregation Interoperability of the Dell PowerConnect M6220 with Cisco IOS or Cisco CatOS Based Switches

Link Aggregation Interoperability of the Dell PowerConnect M6220 with Cisco IOS or Cisco CatOS Based Switches Link Aggregation Interoperability of the Dell PowerConnect M6220 with Cisco IOS or Cisco CatOS Based Switches By Bruce Holmes Introduction This paper describes how to configure the Dell PowerConnect 6220M

More information

Configuring Redundancy

Configuring Redundancy 7 CHAPTER This chapter describes how to configure redundancy and contains these sections: Configuring Fault Tolerance, page 7-1 Configuring HSRP, page 7-5 Configuring Interface and Device Tracking, page

More information

16-PORT POWER OVER ETHERNET WEB SMART SWITCH

16-PORT POWER OVER ETHERNET WEB SMART SWITCH 16-PORT POWER OVER ETHERNET WEB SMART SWITCH User s Manual (DN-95312) - 0 - Content Web Smart Switch Configure login ---------------------------------- 2 Administrator Authentication Configuration ---------------------------------------------

More information

Multiprotocol Label Switching Load Balancing

Multiprotocol Label Switching Load Balancing Multiprotocol Label Switching Load Balancing First Published: July 2013 The Cisco ME 3800 and ME 3600 switches support IPv4 and IPv6 load balancing at the LER and LSR. Effective with Cisco IOS Release

More information

ALLNET ALL-SG8926PM Layer 2 FULL Management 24 Port Giga PoE Current Sharing Switch IEEE802.3at/af

ALLNET ALL-SG8926PM Layer 2 FULL Management 24 Port Giga PoE Current Sharing Switch IEEE802.3at/af ALLNET ALL-SG8926PM Layer 2 FULL Management 24 Port Giga PoE Current Sharing Switch IEEE802.3at/af 24-Port Giga PoE Current Sharing 500W PoE Budget IPv6 and IPv4 Dual Protocol SNMP v1/v2c/v3 SSH version

More information

Objectives. The Role of Redundancy in a Switched Network. Layer 2 Loops. Broadcast Storms. More problems with Layer 2 loops

Objectives. The Role of Redundancy in a Switched Network. Layer 2 Loops. Broadcast Storms. More problems with Layer 2 loops ITE I Chapter 6 2006 Cisco Systems, Inc. All rights reserved. Cisco Public 1 Objectives Implement Spanning Tree Protocols LAN Switching and Wireless Chapter 5 Explain the role of redundancy in a converged

More information

LiveAction Application Note

LiveAction Application Note LiveAction Application Note Layer 2 Monitoring and Host Location Using LiveAction to monitor and identify inter-/intra-switch VLAN configurations, and locating workstations within the network infrastructure.

More information

Virtual Networking Features of the VMware vnetwork Distributed Switch and Cisco Nexus 1000V Series Switches

Virtual Networking Features of the VMware vnetwork Distributed Switch and Cisco Nexus 1000V Series Switches Virtual Networking Features of the vnetwork Distributed Switch and Cisco Nexus 1000V Series Switches What You Will Learn With the introduction of ESX, many virtualization administrators are managing virtual

More information

Lab 5.3.5 Configuring Basic Router Settings with the Cisco IOS CLI

Lab 5.3.5 Configuring Basic Router Settings with the Cisco IOS CLI Lab 5.3.5 Configuring Basic Router Settings with the Cisco IOS CLI Device Host Name Interface IP Address Subnet Mask R1 R1 Serial 0/0/0 (DCE) 172.17.0.1 255.255.0.0 FastEthernet 0/0 172.16.0.1 255.255.0.0

More information

BLADE PVST+ Spanning Tree and Interoperability with Cisco

BLADE PVST+ Spanning Tree and Interoperability with Cisco BLADE PVST+ Spanning Tree and Interoperability with Cisco Technical Brief Industry-standard PVST+ Spanning Tree Protocol with Cisco interoperability Introduction...1 Spanning Tree Protocol (IEEE 802.1d)...1

More information

CMA5000 SPECIFICATIONS. 5710 Gigabit Ethernet Module

CMA5000 SPECIFICATIONS. 5710 Gigabit Ethernet Module CMA5000 5710 Gigabit Ethernet Module SPECIFICATIONS General Description The CMA5710 Gigabit Ethernet application is a single slot module that can be used in any CMA 5000. The Gigabit Ethernet test module

More information

Expert Reference Series of White Papers. Planning for the Redeployment of Technical Personnel in the Modern Data Center

Expert Reference Series of White Papers. Planning for the Redeployment of Technical Personnel in the Modern Data Center Expert Reference Series of White Papers Planning for the Redeployment of Technical Personnel in the Modern Data Center [email protected] www.globalknowledge.net Planning for the Redeployment of

More information

TP-LINK. 24-Port Gigabit L2 Managed Switch with 4 SFP Slots. Overview. Datasheet TL-SG5428. www.tp-link.com

TP-LINK. 24-Port Gigabit L2 Managed Switch with 4 SFP Slots. Overview. Datasheet TL-SG5428. www.tp-link.com TP-LINK TM 24-Port Gigabit L2 Managed Switch with 4 SFP Slots Overview Designed for workgroups and departments, from TP-LINK provides full set of layer 2 management features. It delivers maximum throughput

More information

TP-LINK. 24-Port 10/100Mbps + 4-Port Gigabit L2 Managed Switch. Overview. Datasheet TL-SL5428E. www.tp-link.com

TP-LINK. 24-Port 10/100Mbps + 4-Port Gigabit L2 Managed Switch. Overview. Datasheet TL-SL5428E. www.tp-link.com TP-LINK 24-Port 10/100Mbps + 4-Port Gigabit L2 Managed Switch Overview TP-LINK JetStream L2 managed switch provides high performance, enterprise-level QoS, advanced security strategies and rich layer 2

More information

CCT vs. CCENT Skill Set Comparison

CCT vs. CCENT Skill Set Comparison Operation of IP Data Networks Recognize the purpose and functions of various network devices such as Routers, Switches, Bridges and Hubs Select the components required to meet a given network specification

More information

Juniper / Cisco Interoperability Tests. August 2014

Juniper / Cisco Interoperability Tests. August 2014 Juniper / Cisco Interoperability Tests August 2014 Executive Summary Juniper Networks commissioned Network Test to assess interoperability, with an emphasis on data center connectivity, between Juniper

More information

Configuring IPsec VPN Fragmentation and MTU

Configuring IPsec VPN Fragmentation and MTU CHAPTER 5 This chapter provides information about configuring IPsec VPN fragmentation and the maximum transmission unit (MTU). It includes the following sections: Understanding IPsec VPN Fragmentation

More information

Cisco Catalyst 2960-S FlexStack: Description, Usage, and Best Practices

Cisco Catalyst 2960-S FlexStack: Description, Usage, and Best Practices Cisco Catalyst 2960-S FlexStack: Description, Usage, and Best Practices Introduction Cisco FlexStack stacking for Cisco Catalyst 2960-S Series Switches provides a true stacking solution with all switches

More information

ZyXEL GS2210-8HP V4.10(AASQ.1)C0 Release Note/Manual Supplement

ZyXEL GS2210-8HP V4.10(AASQ.1)C0 Release Note/Manual Supplement ZyXEL GS2210-8HP V4.10(AASQ.1)C0 Release Note/Manual Supplement Date: May. 5, 2015 This document describes the features in the GS2210-8HP product for its 4.10(AASQ.1)C0 release. Support Platforms: ZyXEL

More information

Nutanix Tech Note. VMware vsphere Networking on Nutanix

Nutanix Tech Note. VMware vsphere Networking on Nutanix Nutanix Tech Note VMware vsphere Networking on Nutanix Nutanix Virtual Computing Platform is engineered from the ground up for virtualization and cloud environments. This Tech Note describes vsphere networking

More information

Cisco Unified Access Technology Overview: Converged Access

Cisco Unified Access Technology Overview: Converged Access White Paper Cisco Unified Access Technology Overview: Converged Access Introduction Today, less than 1 percent of things in the physical world are network connected. In the near future the growth of the

More information

CHAPTER 10 LAN REDUNDANCY. Scaling Networks

CHAPTER 10 LAN REDUNDANCY. Scaling Networks CHAPTER 10 LAN REDUNDANCY Scaling Networks CHAPTER 10 10.0 Introduction 10.1 Spanning Tree Concepts 10.2 Varieties of Spanning Tree Protocols 10.3 Spanning Tree Configuration 10.4 First-Hop Redundancy

More information

APOSTILA DE REDES DE COMPUTADORES PARTE VI SWITCH

APOSTILA DE REDES DE COMPUTADORES PARTE VI SWITCH APOSTILA DE REDES DE COMPUTADORES PARTE VI SWITCH 1 1. Criando um Banner de Login REDE DE COMPUTADORES VI SALESIANO#conf t SALESIANO(config)#banner motd c Enter TEXT message. End with the character 'c'.

More information

Ethernet Storage Best Practices

Ethernet Storage Best Practices Technical Report Ethernet Storage Best Practices David Klem, Trey Layton, Frank Pleshe, NetApp January 2010 TR-3802 TABLE OF CONTENTS 1 INTRODUCTION... 3 2 USING VLANS FOR TRAFFIC SEPARATION... 3 2.1 VLAN

More information

TP-LINK. 24-Port Gigabit L2 Managed PoE Switch with 4 Combo SFP Slots. Overview. Datasheet TL-SG3424P. www.tp-link.com

TP-LINK. 24-Port Gigabit L2 Managed PoE Switch with 4 Combo SFP Slots. Overview. Datasheet TL-SG3424P. www.tp-link.com TP-LINK TM 24-Port Gigabit L2 Managed PoE Switch with 4 Combo SFP Slots Overview The provides 24 10/100/1000Mbps ports that supports 802.3at/af-compliant PoE, with a total PoE power supply up to 320W,

More information

Configuring QoS and Per Port Per VLAN QoS

Configuring QoS and Per Port Per VLAN QoS 27 CHAPTER This chapter describes how to configure quality of service (QoS) by using automatic QoS (auto-qos) commands or by using standard QoS commands on a Catalyst 45 series switch. It also describes

More information

Cisco Nexus 5548UP. Switch Configuration Guide for Dell PS Series SANs. A Dell Deployment and Configuration Guide

Cisco Nexus 5548UP. Switch Configuration Guide for Dell PS Series SANs. A Dell Deployment and Configuration Guide Cisco Nexus 5548UP Switch Configuration Guide for Dell PS Series SANs Dell Storage Engineering October 2015 A Dell Deployment and Configuration Guide Revisions Date February 2013 October 2013 March 2014

More information

Design and Configuration Guide: Best Practices for Virtual Port Channels (vpc) on Cisco Nexus 7000 Series Switches

Design and Configuration Guide: Best Practices for Virtual Port Channels (vpc) on Cisco Nexus 7000 Series Switches Guide Design and Configuration Guide: Best Practices for Virtual Port Channels (vpc) on Cisco Nexus 7000 Series Switches Revised: November 2015 2015-2016 Cisco and/or its affiliates. All rights reserved.

More information

hp ProLiant network adapter teaming

hp ProLiant network adapter teaming hp networking june 2003 hp ProLiant network adapter teaming technical white paper table of contents introduction 2 executive summary 2 overview of network addressing 2 layer 2 vs. layer 3 addressing 2

More information

TP-LINK. 24-Port Gigabit Smart PoE Switch with 4 Combo SFP Slots. Overview. Datasheet TL-SG2424P. www.tp-link.com

TP-LINK. 24-Port Gigabit Smart PoE Switch with 4 Combo SFP Slots. Overview. Datasheet TL-SG2424P. www.tp-link.com Power Budget TP-LINK 24-Port Gigabit Smart PoE Switch with 4 Combo SFP Slots Overview The provides 24 10/100/1000Mbps ports that supports 802.3at/af-compliant PoE, with a total PoE power supply up to 180W,

More information

VMDC 3.0 Design Overview

VMDC 3.0 Design Overview CHAPTER 2 The Virtual Multiservice Data Center architecture is based on foundation principles of design in modularity, high availability, differentiated service support, secure multi-tenancy, and automated

More information

The Basics. Configuring Campus Switches to Support Voice

The Basics. Configuring Campus Switches to Support Voice Configuring Campus Switches to Support Voice BCMSN Module 7 1 The Basics VoIP is a technology that digitizes sound, divides that sound into packets, and transmits those packets over an IP network. VoIP

More information

TP-LINK 24-Port Gigabit L2 Managed Switch with 4 SFP Slots

TP-LINK 24-Port Gigabit L2 Managed Switch with 4 SFP Slots NEW TP-LINK 24-Port Gigabit L2 Managed Switch with 4 SFP Slots TM NEW Overview Designed for workgroups and departments, from TP-LINK provides full set of layer 2 management features. It delivers maximum

More information

Cisco 7600 Series Route Switch Processor 720

Cisco 7600 Series Route Switch Processor 720 Cisco 7600 Series Route Switch Processor 720 Product Overview The Cisco 7600 Series Route Switch Processor 720 (RSP 720) is specifically designed to deliver high scalability, performance, and fast convergence

More information

JetNet 5428Gv2. Features. Industrial 24FE+4G Gigabit Managed Ethernet Switch INDUSTRIAL ETHERNET RACKMOUNT SWITCH

JetNet 5428Gv2. Features. Industrial 24FE+4G Gigabit Managed Ethernet Switch INDUSTRIAL ETHERNET RACKMOUNT SWITCH INDUSTRIAL ETHERNET RACKMOUNT SWITCH Industrial 24FE+4G Gigabit Managed Ethernet Switch JetNet 5428Gv2 The JetNet 5428G is a 19-inch Gigabit Layer 2+ Industrial switch, equipped with 24 100 Base-TX ports

More information