Data Mining for Sustainable Data Centers
|
|
|
- Jordan Baldwin
- 10 years ago
- Views:
Transcription
1 Data Mining for Sustainable Data Centers Manish Marwah Senior Research Scientist Hewlett Packard Laboratories 2009 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice
2 Overview Sustainability and Data Centers Data mining applications Chiller operation characterization PV prediction Anomaly detection 2
3 Motivation Industry challenge: Create technologies, IT infrastructure and business models for the low-carbon economy IT industry 2% Total carbon emissions Aviation 2% The footprint of IT will need to be reduced quite significantly in a low-carbon economy. 3 3 June 2013
4 Sustainability sustainable development is development that meets the needs of the present without compromising the ability of future generations to meet their own needs the Brundtland Commission of the United Nations, June 2013
5 Sustainability What do I mean by sustainability? Risk: Ecological Damage Social ( People ) Sustainable Risk: Commercially unfeasibility Economic ( Profit ) Environmental ( Planet ) Risk: Limited Adoption 5 4 June 2013 Figure Credit: A. Agogino, UC Berkeley
6 Environmental Sustainability Impact factors (e.g., carbon, water, toxicity, etc.) Life Cycle View 6 3 June 2013
7 Handheld Notebook Desktop Blade Server Data Center Fraction of Lifecycle Energy Sustainable Data Centers Lifecycle Assessment 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 0% Operational Embedded Ref: IEEE Computer 2009 Results are illustrative only. Actual footprint may differ. 7 3 June 2013
8 Cloud Data Center Supply and Demand Side Q data center Cooling Power Warm Water Air Mixture In Cooling Tower loop W p Switch Gear Makeup Water Return Water Q Cond UPS PDU Computing CHILLER Q Evap W p Chilled Water loop 8 Copyright 2011 Hewlett-Packard Company Chandrakant D. Patel; [email protected] Data Center
9 Power(kW) power (KW) Supply and Demand in a Data Center IT Services PV Onsite Power Grid Biogas PV Supply critical workload non-critical workload cooling power Time(hour) time (hour) Ecosystem of Clients Mechanical Cooling Supply Local Cooling Grid Demand IT Infrastructure Outside Air 9 U Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Ground Loops
10 Sustainable Operation and Management of Chillers using Temporal Data Mining (KDD 09) 10 Data Centers Cooling Infrastructure Problem Statement Prior Work Our Approach Symbolic representation Event encoding Motif mining Sustainability characterization Experimental Results Summary
11 Data Center Cooling Infrastructure Consumes from 1/3 up to 1/2 of total power consumption Cooling Towers Water Return (T in ) Chiller Unit Water Supply (T out ) 11 Computer room air-conditioner (CRAC)
12 Ensemble of Chillers Challenging to operate efficiently Complex physical system Dynamic Heterogeneous Inter-dependencies Many constraints Accurate models not available Rapid cycles undesirable reduce lifespan Domain experts determine settings based on heuristics Can it be automated through a datadriven approach? Chiller Ensemble Which unit to turn ON/OFF? At what utilization? How to handle increase/decrease in cooling load? 12
13 Problem Statement Given the following chiller time series utilization levels power consumption cooling loads Is it possible to determine which operational settings are more energy efficient? And then use this information to advise data center facility operators 13
14 Some Terminology IT cooling load Chiller utilization Chiller power consumption Coefficient of performance (COP) Cooling Load Power consumption 14
15 Prior Work Classical approaches to model time series data Principal component analysis Discrete Fourier transforms Discrete representations: SAX [Keogh et al.] Motifs: Repeating subsequences [Yankov et al.] 15
16 Our approach Goal: Sustainability characterization of multi- variate time series data Chiller utilization data Four Main Steps Symbolic representation Event encoding Motif mining Sustainability Characterization Other discrete data sources can be integrated Multivariate Time Series Data Cluster Analysis Event Encoding Frequent Motif Mining Sustainability characterization of frequent motifs Symbolic representation Transition-event sequence Frequent motifs 16
17 Clustering Individual vector: Utilization across all chiller units Raw Data: Sequence of such vectors Perform k-means clustering Use cluster labels to encode multi-variate time series 17
18 Some Definitions 18 Event Sequence Episode ( E, t ),( E 1 2, t 2 E i = Event type t i = Time of occurrence Ordered collection of events occurring together Episode occurrence Events same ordering as episode in the data. Motifs Frequently occurring episodes ),...,( E N, t 1 N ( A,1),( B,3),( D,4),( C,6),( A,12),( E,14),( B,15),( D,17),( C,20),( A,21) A B <(A,1), (B,3), (D,4), (C,6), (E,12), (A,14), (B,15), (C,17)> ) C
19 Redescribing time series data Perform run-length encoding: Note transitions from one symbol to another Higher level of abstraction Transition events 19
20 Level-wise (Apriori-based) motif mining Candidate generation followed by counting 20 3 June 2013
21 Multi-variate time-series Methodology Summary Vector representation Clustering Discrete representation of chiller ensemble time-series aabbbbbaaaxaaacccccaaaaabbbbbbaaeaaaaaacccccbggaaa Transition Encoding aabbbbbaaaxaaacccccaaaaabbbbbbaaeaaaaaacccccbggaaa Frequent Episode Mining Occurrence #1 Occurrence #2 Motif ab->ba->ac 21
22 Sustainability characterization of Motifs Average motif COP (coefficient of performance) Indicates cooling efficiency of a chiller unit COP = IT Cooling Load Power consumed Frequency of oscillations of a motif Impacts chiller lifespan Normalized number of mean-crossings 22
23 Experimental Results Data From HP R&D data center in Bangalore 70,000 sq ft 2000 racks of IT equipments Ensemble of five chiller units 3 air cooled chillers 2 water cooled chillers 480 hours of data July 2 7, Nov 27 30, Dec 16 26, motifs found in the data 23
24 A Motif Detailed Example (1/3) Time Series Symbol seq: 11,11,11,8,8,8,8,10,10,10,10,10,10,10,10,10,10,10,10,10,10,10,13,14,12,12,11,11,11 Encoded seq: 11-8, , , , , , Transition Motif: [ 11-8, 8-10, 10-13, 13-14, 14-12, ] Inter-transition gap constraint = 20 min 24
25 A Motif Detailed Example (2/3) Time Series Symbol seq: 11,11,11,8,8,8,10,10,10,10,10,10,10,10,10,10,10,10,10,13,13,14,12,12,11,11,11 Encoded seq: 11-8, , , , , , Transition Motif: [ 11-8, 8-10, 10-13, 13-14, 14-12, ] Inter-transition gap constraint = 20 min 25
26 A Motif Detailed Example (3/3) Time Series Symbol seq: 11,11,11,8,8,8,10,10,10,10,10,10,10,10,10,10,10,10,10,10,13,14,12,12,12,11,11,11 Encoded seq: 11-8, , , , , , Transition Motif: [ 11-8, 8-10, 10-13, 13-14, 14-12, ] Inter-transition gap constraint = 20 min 26
27 Two Interesting Motifs Chiller C1 18% 34% C2 49% 11% C3 44% 0% C4 0% 66% C5 0% 0% C1, C2, C3 Air cooled C4, C5 Water cooled Time (min) Motif 8 Motif 5 Motif 8 Motif 5 COP Units operating 3 air-cooled 2 air-cooled, 1 water cooled 27
28 Potential Savings Annual saving from operating in Motif 5 instead of Motif 8 Cost savings = $40,000 (~10%) Carbon footprint savings = 287,328 kg of CO 2 28
29 Summary Data center chillers consume substantial power Ensemble of chillers part of data center cooling infrastructure are challenging to operate energy efficiently Mine and characterize motifs Symbolic representation Event encoding Motif mining Sustainability characterization Demonstrated our approach on data from a real data center indicates significant potential energy savings 29
30 Chiller COP The Net-Zero Energy Data Center Implementation in Palo Alto PV micro grid Data center Outside air Cooling infrastructure power demand Load (kw) Outside Air Temperature ( C) Data center supply side Data center demand side 30 Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
31 power (KW) power (KW) Power (kw) Power(kW) Net-Zero Energy Methodology and Integration Prediction PV Supply Planning Supply-side Prediction Renewable power prediction Cooling capacity prediction Time(hour) Outside Air Cooling Available Capacity DC Operation Objectives: Net-zero energy operation Maximize use of renewable energy Minimize dependability on Grid IT Demand Prediction Time (hour) critical workload non-critical workload cooling power IT Workload Planning Integrate Supply and Demand Side IT Demand Shaping Power capping time (hour) Verification and Reporting Measurement Verification Execution 1 0 critical workload non-critical workload cooling power renewable supply time (hour) Dynamic IT Provisioning Ref: Z. Liu, Copyright Y. Chen, 2012 C. Bash, Hewlett-Packard A. Wierman, Development D. Gmach, 31 Company, Z. Wang, L.P. M. Marwah, The information C. Hyser, contained "Renewable herein is and subject Cooling to change Aware without notice. Workload Management for Sustainable Data Centers", ACM SIGMETRICS/Performance, June , London, UK. Dynamic Cooling Provisioning
32 CPU Demand (number of CPUs) Power (kw) PV Power (kw) Prediction: Summary PV Supply Prediction Search for most similar days in the recent past Hourly generation estimated from corresponding hours of similar days Ref: P. Chakraborty, M. Marwah, M. Arlitt, N. Ramakrishnan, Fine-grained Photovoltaic Output Prediction Using a Bayesian Ensemble, in Proceedings of the 26th Conference on Artificial Intelligence (AAAI'12), Toronto, Canada, July 2012 Cooling Capacity Prediction End-to-End Energy Modeling actual power predicted power time (hour) Outside Air Cooling Available Capacity Ref: Breen, T.J. et. al. From Chip to Cooling Tower Data Center Modeling: Validation of Multi-Scale Energy Management Model, Proceedings of Itherm, June 2012 IT Workload Prediction Time (hour) predicted workload actual workload Perform a periodicity analysis (e.g., Fast Fourier Transform) Use an auto-regressive model to predict workload from historical data Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice time (hour)
33 Power(kW) Fine grained PV Prediction using Bayesian Ensemble Motivation Integration of renewable sources is an important goal of the smart grid effort PV output is variable and intermittent Knowledge of future PV output enables demand-side management and shaping in data centers Problem addressed PV Supply Predict PV output for the next day Data Time(hour) Historical PV output data for about 9 months from the HPL Palo Alto site Weather data (AAAI 2012)
34 Fine grained PV Prediction using Bayesian Ensemble Approach Extract daily profiles from training data Use ensemble of predictors Naïve Bayes K-NN Motif based Perform Bayesian model averaging Results (AAAI 2012)
35 Fine grained PV Prediction using Bayesian Ensemble Results Error by weather condition Actual versus predicted (AAAI 2012)
36 power (KW) power (KW) Planning: Supply-Side Aware IT Workload Planning Planning Flow Demand Shaping electricity price renewable supply cooling capacity efficiency energy storage IT workload & SLAs goals Demand critical workload non-critical workload cooling power demand shaping Optimal Net Zero Plan critical workload non-critical workload cooling power renewable supply 0.2 Workload Planning time (hour) time (hour) A detailed workload scheduling and capacity allocation plan Workload scheduling plan IT resource and power capacity allocation Cooling micro-grid capacity allocation Overall demand is shaped according to input constraints and operation objectives Satisfy critical workload resource requirements Ref: Z. Liu, Y. Chen, C. Bash, A. Wierman, D. Gmach, Z. Wang, M. Marwah, C. Hyser, "Renewable and Cooling Aware Workload Management for Sustainable Data Centers", ACM SIGMETRICS/Performance, June , London, UK. 36 Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
37 Power and Workload Visualization medium low Before optimization After optimization
38 Some other projects Anomaly detection (SensorKDD 2010) Energy Disaggregation (SDM 2011, AAAI 2013) Automating Life Cycle Assessment (IEEE Computer 2011) Building Energy Management (BuildSys 2011) 38 3 June 2013
39 Anomalous Thermal Behavior Detection using PCA Example: Event (Anomaly) Detection Period of increased energy consumption (17 % increase) Rack D5 Switch turned on Normal energy consumption Network Switch Start: :44:34 End: :58: (SensorKDD 2010)
40 Energy Disaggregation
41 Proposed Variant of Factorial HMM s (SDM 2011)
42 References P. Chakraborty, M. Marwah, M. Arlitt, and N. Ramakrishnan. Fine-grained Photovoltaic Output Prediction using a Bayesian Ensemble, in Proceedings of the 26th Conference on Artificial Intelligence (AAAI'12), Toronto, Canada, 7 pages, July 2012, To appear. Z. Liu, Y. Chen, C. Bash, A. Wierman, D. Gmach, Z. Wang, M. Marwah, C. Hyser, "Renewable and Cooling Aware Workload Management for Sustainable Data Centers", ACM SIGMETRICS/Performance, June , London, UK. Manish Marwah, Amip Shah, Cullen Bash, Chandrakant Patel, Naren Ramakrishnan, "Using Data Mining to Help Design Sustainable Products," IEEE Computer, August 2011 Hyungsul Kim, Manish Marwah, Martin Arlitt, Geoff Lyon and Jiawei Han, "Unsupervised Disaggregation of Low Frequency Power Measurements", SIAM International Conference on Data Mining (SDM 11), Mesa, Arizona, April 28-30, Gowtham Bellala, Manish Marwah, Martin Arlitt, Geoff Lyon, Cullen Bash, "Towards an understanding of campus-scale power consumption." In ACM BuildSys, November 1, 2011, Seattle, WA. Manish Marwah, Ratnesh Sharma, Wilfredo Lugo, Lola Bautista, "Anomalous Thermal Behavior Detection in Data Centers using Hierarchical PCA," in SensorKDD in conjunction with KDD D. Patnaik, M. Marwah, Sharma, Ramakrishna, "Sustainable Operation and Management of Data Center Chillers using Temporal Data Mining," In ACM KDD, June 27 - July 1, 2009, Paris, France. Amip Shah, Tom Christian, Chandrakant D. Patel, Cullen Bash, Ratnesh K. Sharma: Assessing ICT's Environmental Impact. IEEE Computer 42(7): 91-93, July 2009.
Data Mining for Modeling Chiller Systems in Data Centers
Data Mining for Modeling Chiller Systems in Data Centers Debprakash Patnaik 1, Manish Marwah 2, Ratnesh K. Sharma 2, and Naren Ramakrishnan 1 1 Virginia Tech, Blacksburg, VA 24061, USA 2 HP Labs, Palo
Automated Synthesis of Sustainable Data Centers
Automated Synthesis of Sustainable Data Centers Tom Christian, Yuan Chen, Rocky Shih, Ratnesh Sharma, Christopher Hoover, Manish Marwah, Amip Shah, Daniel Gmach Sustainable IT Ecosystem Laboratory Hewlett-Packard
Visual exploration of frequent patterns in multivariate time series
430769IVI0010.1177/1473871611430769Hao et al.information Visualization 2011 Article Visual exploration of frequent patterns in multivariate time series Information Visualization 0(0) 1 13 The Author(s)
Fine-grained Photovoltaic Output Prediction using a Bayesian Ensemble
Fine-grained Photovoltaic Output Prediction using a Bayesian Ensemble Prithwish Chakraborty 1,2, Manish Marwah 3, Martin Arlitt 3, and Naren Ramakrishnan 1,2 1 Department of Computer Science, Virginia
Visual Exploration of Frequent Patterns in Multivariate Time Series
Visual Exploration of Frequent Patterns in Multivariate Time Series Ming C. Hao 1, Manish Marwah 1, Halldór Janetzko 2, Umeshwar Dayal 1, Daniel A. Keim 2, Debprakash Patnaik 3, Naren Ramakrishnan 3 and
Renewable and Cooling Aware Workload Management for Sustainable Data Centers
Renewable and Cooling Aware Workload Management for Sustainable Data Centers Zhenhua Liu, Yuan Chen 2, Cullen Bash 2, Adam Wierman, Daniel Gmach 2, Zhikui Wang 2, Manish Marwah 2, and Chris Hyser 2 California
Data analysis, Visualization and Knowledge Discovery in Sustainable Data Centers
Data analysis, Visualization and Knowledge Discovery in Sustainable Data Centers Manish Marwah, Ratnesh Sharma, Rocky Shih, Chandrakant Patel Hewlett-Packard Laboratories Palo Alto, CA, USA Vaibhav Bhatia,
Data centers & energy: Did we get it backwards? Adam Wierman, Caltech
Data centers & energy: Did we get it backwards? Adam Wierman, Caltech The typical story about energy & data centers: The typical story about energy & data centers: Sustainable data centers Remember: The
Cost Model for Planning, Development and Operation of a Data Center
Cost Model for Planning, Development and Operation of a Data Center Chandrakant D. Patel, Amip J. Shah 1 Internet Systems and Storage Laboratory HP Laboratories Palo Alto HPL-005-107(R.1) June 9, 005*
Algorithms for sustainable data centers
Algorithms for sustainable data centers Adam Wierman (Caltech) Minghong Lin (Caltech) Zhenhua Liu (Caltech) Lachlan Andrew (Swinburne) and many others IT is an energy hog The electricity use of data centers
Stochastic Model Predictive Control for data centers
A data center is a facility that centralizes an organization s IT operations and equipment, and where the organization stores, manages, and disseminates its data. Data centers are the pillar of our IT
Energy Efficient Cloud Computing: Challenges and Solutions
Energy Efficient Cloud Computing: Challenges and Solutions Burak Kantarci and Hussein T. Mouftah School of Electrical Engineering and Computer Science University of Ottawa Ottawa, ON, Canada 08 September
supported Application QoS in Shared Resource Pools
Supporting Application QoS in Shared Resource Pools Jerry Rolia, Ludmila Cherkasova, Martin Arlitt, Vijay Machiraju HP Laboratories Palo Alto HPL-2006-1 December 22, 2005* automation, enterprise applications,
Data Center Optimization Methodology to Maximize the Usage of Locally Produced Renewable Energy
Data Center Optimization Methodology to Maximize the Usage of Locally Produced Renewable Energy Tudor Cioara, Ionut Anghel, Marcel Antal, Sebastian Crisan, Ioan Salomie Computer Science Department Technical
Model-Based Approach for Optimizing a Data Center Centralized Cooling System
Model-Based Approach for Optimizing a Data Center Centralized Cooling System Monem H. Beitelmal, Chandrakant D. Patel Enterprise Software and Systems Laboratory HP Laboratories Palo Alto HPL-6-67 April
Energy Smart Data Center Phase-III R&D. Andrés Márquez. Pacific Northwest National Laboratory
Energy Smart Data Center Phase-III R&D Andrés Márquez Pacific Northwest National Laboratory Overall Task Division Advance spraycooling technology (ISR) Advance 3D chip scale packing technology (Tessera)
Vitocaldens 222-F Compact Gas-Hybrid appliance
Vitocaldens 222-F Compact Gas-Hybrid appliance Heating systems Industrial systems Refrigeration systems 2/3 Vitocaldens 222-F: The future-proof energy-source mix in one appliance Choosing Vitocaldens
Data Center RD&D at EPRI
Data Center RD&D at EPRI Mukesh Khattar Technical Executive Critical facilities Round Table Meeting Palo Alto, CA 16 October 2015 EPRI Focus for Data Centers RD&D Address problems facing the member electric
Solve your IT energy crisis WITH An energy SMArT SoluTIon FroM Dell
Solve your IT energy crisis WITH AN ENERGY SMART SOLUTION FROM DELL overcome DATA center energy challenges IT managers share a common and pressing problem: how to reduce energy consumption and cost without
Data Center Infrastructure Management: ERP for the Data Center Manager
Data Center Infrastructure Management: ERP for the Data Center Manager 1 2 Topics What s DCIM & the ERP Analogy Why DCIM How DCIM Works How DCIM Helps 3 DCIM by Definition DCIM is a system that collects
Control Strategies for Plenum Optimization in Raised Floor Data Centers
Control Strategies for Plenum Optimization in aised Floor Data Centers Keke Chen, Clifford C. Federspiel, David M. Auslander, Cullen E. Bash, Chandrakant D. Patel Enterprise Software and Systems Laboratory
Leveraging Thermal Storage to Cut the Electricity Bill for Datacenter Cooling
Leveraging Thermal Storage to Cut the Electricity Bill for Datacenter Cooling Yefu Wang1, Xiaorui Wang1,2, and Yanwei Zhang1 ABSTRACT The Ohio State University 14 1 1 8 6 4 9 8 Time (1 minuts) 7 6 4 3
Enabling an agile Data Centre in a (Fr)agile market
Enabling an agile Data Centre in a (Fr)agile market Phil Dodsworth Director, Data Centre Solutions 2008 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without
Green HPC - Dynamic Power Management in HPC
Gr eenhpc Dynami cpower Management i nhpc AT ECHNOL OGYWHI T EP APER Green HPC Dynamic Power Management in HPC 2 Green HPC - Dynamic Power Management in HPC Introduction... 3 Green Strategies... 4 Implementation...
Energy Efficient Systems
Energy Efficient Systems Workshop Report (September 2014) Usman Wajid University of Manchester United Kingdom Produced as a result of Workshop on Energy Efficient Systems @ ICT4S conference, Stockholm
Bytes and BTUs: Holistic Approaches to Data Center Energy Efficiency. Steve Hammond NREL
Bytes and BTUs: Holistic Approaches to Data Center Energy Efficiency NREL 1 National Renewable Energy Laboratory Presentation Road Map A Holistic Approach to Efficiency: Power, Packaging, Cooling, Integration
environmental sustainability at HP HP Sustainability Helping Norfolk County Council reduce environmental and expand opportunities
Environmental HP Sustainability sustainability at HP Helping Norfolk County Council reduce environmental Helping impact you and reduce expand environmental opportunities impact and expand opportunities
ICT and the Green Data Centre
ICT and the Green Data Centre Scott McConnell Sales Manager c/o Tanya Duncan MD Interxion Ireland Green Data Centres Our Responsibility Data centre greenhouse gas emissions are projected to quadruple by
Comparative Analysis of EM Clustering Algorithm and Density Based Clustering Algorithm Using WEKA tool.
International Journal of Engineering Research and Development e-issn: 2278-067X, p-issn: 2278-800X, www.ijerd.com Volume 9, Issue 8 (January 2014), PP. 19-24 Comparative Analysis of EM Clustering Algorithm
THE WORLD S MOST EFFICIENT DATA CENTER
THE WORLD S MOST EFFICIENT DATA CENTER HP POD 240a Ed Turkel Manager, WW HPC Marketing Hyperscale Business Unit 2011 Hewlett-Packard Development Company, L.P. The information contained herein is subject
Thermal Management of Datacenter
Thermal Management of Datacenter Qinghui Tang 1 Preliminaries What is data center What is thermal management Why does Intel Care Why Computer Science 2 Typical layout of a datacenter Rack outlet temperature
Page 1. White Paper, December 2012 Gerry Conway. How IT-CMF can increase the Energy Efficiency of Data Centres
Page 1 White Paper, December 2012 Gerry Conway How IT-CMF can increase the Energy Efficiency of Data Centres Abstract Data centres and their management are under increasing pressure; to increase the efficiency
Demand Response in Data Centers Feasibility and Proof of Concept Demonstration
Demand Response in Data Centers Feasibility and Proof of Concept Demonstration Jay Madden, SCE; Mukesh Khattar, EPRI; Henry Wong, Intel; Chris Battista, Calit2 CalPlug Workshop Series #7 University of
DATA CENTER ASSESSMENT SERVICES
DATA CENTER ASSESSMENT SERVICES ig2 Group Inc. is a Data Center Science Company which provides solutions that can help organizations automatically optimize their Data Center performance, from assets to
DataCenter 2020: first results for energy-optimization at existing data centers
DataCenter : first results for energy-optimization at existing data centers July Powered by WHITE PAPER: DataCenter DataCenter : first results for energy-optimization at existing data centers Introduction
Green ICT: Consistent Actions to Reduce Energy Consumption
/ Martin Chaloupek Vienna, 2010 02 22 Green ICT: Consistent Actions to Reduce Energy Consumption Input to Conference Energy Efficiency Chances of Green ICT and Electronics Vienna, 2010 03 05 20010 IBM
Bayesian networks - Time-series models - Apache Spark & Scala
Bayesian networks - Time-series models - Apache Spark & Scala Dr John Sandiford, CTO Bayes Server Data Science London Meetup - November 2014 1 Contents Introduction Bayesian networks Latent variables Anomaly
Harmonizing Global Metrics for Data Center Energy Efficiency
Harmonizing Global Metrics for Data Center Energy Efficiency Dan Azevedo, Symantec Chairman - Metrics & Measurements Work Group Industry Trends Energy Efficient IT The Climate Group: Smarter technology
Comparing the Carbon Footprints of 11G and 12G Rack Servers from Dell
Comparing the Carbon Footprints of 11G and 12G Rack Servers from Dell Markus Stutz, Regulatory Principal Engineer, Environmental Affairs August 2013. Contents Comparing two rack server generations... 4
DATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER
DATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER DATA CENTERS 2009 IT Emissions = Aviation Industry Emissions Nations Largest Commercial Consumers of Electric Power Greenpeace estimates
Setting deadlines and priorities to the tasks to improve energy efficiency in cloud computing
Setting deadlines and priorities to the tasks to improve energy efficiency in cloud computing Problem description Cloud computing is a technology used more and more every day, requiring an important amount
The CEETHERM Data Center Laboratory
The CEETHERM Data Center Laboratory A Platform for Transformative Research on Green Data Centers Yogendra Joshi and Pramod Kumar G.W. Woodruff School of Mechanical Engineering Georgia Institute of Technology
How To Schedule Cloud Computing On A Data Center
An Efficient Scheduling of HPC Applications on Geographically Distributed Cloud Data Centers Aboozar Rajabi 1, Hamid Reza Faragardi 2, Thomas Nolte 2 1 School of Electrical and Computer Engineering, University
Smarter Data Centers. Integrated Data Center Service Management
Smarter Data Centers Integrated Data Center Service Management Approx. 3.500 ton CO² is generated by: Diesel Car-6l /100 km 20.000 km Airplane 5 * Brussels-Barcelona Server, 1.5 A, 24*7*365*3.000 Kwhr
Design Best Practices for Data Centers
Tuesday, 22 September 2009 Design Best Practices for Data Centers Written by Mark Welte Tuesday, 22 September 2009 The data center industry is going through revolutionary changes, due to changing market
Energy Efficient Thermal Management of Data Centers
Energy Efficient Thermal Management of Data Centers Yogendra Joshi l Editors Pramod Kumar Energy Efficient Thermal Management of Data Centers Editors Yogendra Joshi G.W. Woodruff School of Mechanical
FloVENT. Optimizing Data Center Cooling by Simulation. Mechanical Analysis
FloVENT Optimizing Data Center Cooling by Simulation Mechanical Analysis Why Perform Airflow/Thermal Simulation in Data Centers? Why Choose FloVENT for Airflow Simulation in Data Centers? Providing adequate
Direct Fresh Air Free Cooling of Data Centres
White Paper Introduction There have been many different cooling systems deployed in Data Centres in the past to maintain an acceptable environment for the equipment and for Data Centre operatives. The
Energy management White paper. Greening the data center with IBM Tivoli software: an integrated approach to managing energy.
Energy management White paper Greening the data center with IBM Tivoli software: an integrated approach to managing energy. May 2008 2 Contents 3 Key considerations for the green data center 3 Managing
Trends in Data Center Design ASHRAE Leads the Way to Large Energy Savings
Trends in Data Center Design ASHRAE Leads the Way to Large Energy Savings ASHRAE Conference, Denver Otto Van Geet, PE June 24, 2014 NREL/PR-6A40-58902 NREL is a national laboratory of the U.S. Department
Modular Data Centre. Flexible, scalable high performance modular data centre solutions. Data Centre Solutions...energy efficient by design
Data Centre Solutions...energy efficient by design Modular Data Centre Flexible, scalable high performance modular data centre solutions Creating an effective workspace environment The Modular Data Centre
Data Center & IT Infrastructure Optimization. Trends & Best Practices. Mickey Iqbal - IBM Distinguished Engineer. IBM Global Technology Services
Data Center & IT Infrastructure Optimization Trends & Best Practices Mickey Iqbal - IBM Distinguished Engineer IBM Global Technology Services IT Organizations are Challenged by a Set of Operational Issues
Dynamic Virtual Machine Allocation in Cloud Server Facility Systems with Renewable Energy Sources
Dynamic Virtual Machine Allocation in Cloud Server Facility Systems with Renewable Energy Sources Dimitris Hatzopoulos University of Thessaly, Greece Iordanis Koutsopoulos Athens University of Economics
Challenges In Intelligent Management Of Power And Cooling Towards Sustainable Data Centre
Challenges In Intelligent Management Of Power And Cooling Towards Sustainable Data Centre S. Luong 1*, K. Liu 2, James Robey 3 1 Technologies for Sustainable Built Environments, University of Reading,
ENERGY EFFICIENT AND REDUCTION OF POWER COST IN GEOGRAPHICALLY DISTRIBUTED DATA CARDS
ENERGY EFFICIENT AND REDUCTION OF POWER COST IN GEOGRAPHICALLY DISTRIBUTED DATA CARDS M Vishnu Kumar 1, E Vanitha 2 1 PG Student, 2 Assistant Professor, Department of Computer Science and Engineering,
Paul Oliver Sales Director. Paul Oliver, Airedale Tom Absalom, JCA
Paul Oliver Sales Director Paul Oliver, Airedale Tom Absalom, JCA Airedale an overview 25,000m 2 UK premier test centre 450 staff Global distribution A Modine company Modine centre of excellence Airedale
Understanding Power Usage Effectiveness (PUE) & Data Center Infrastructure Management (DCIM)
Understanding Power Usage Effectiveness (PUE) & Data Center Infrastructure Management (DCIM) Salim Janbeh Physical Infrastructure Consultant [email protected] PANDUIT You Can t Manage What You Don t Measure:
Measuring Power in your Data Center: The Roadmap to your PUE and Carbon Footprint
Measuring Power in your Data Center: The Roadmap to your PUE and Carbon Footprint Energy usage in the data center Electricity Transformer/ UPS Air 10% Movement 12% Cooling 25% Lighting, etc. 3% IT Equipment
High-density modular data center making cloud easier. Frank Zheng Huawei
High-density modular data center making cloud easier Frank Zheng Huawei 2012-10-10 Content 1 2 3 4 Cloud s impact to data center Concerns of DC construction 4S DC making cloud easier Success stories Cloud?
OPTIMIZATION OF DATA CENTER CHILLED WATER COOLING SYSTEM ACCORDING TO ANNUAL POWER CONSUMPTION CRITERION
OPTIMIZATION OF DATA CENTER CHILLED WATER COOLING SYSTEM ACCORDING TO ANNUAL POWER CONSUMPTION CRITERION Piotr Kowalski 1, Mieczysław Porowski 2 1 Poznan University of Technology Piotrowo 5 60-695 Poznan,
Energy Efficient Data Centre at Imperial College. M. Okan Kibaroglu IT Production Services Manager Imperial College London.
Energy Efficient Data Centre at Imperial College M. Okan Kibaroglu IT Production Services Manager Imperial College London 3 March 2009 Contents Recognising the Wider Issue Role of IT / Actions at Imperial
Effect of Rack Server Population on Temperatures in Data Centers
Effect of Rack Server Population on Temperatures in Data Centers Rajat Ghosh, Vikneshan Sundaralingam, Yogendra Joshi G.W. Woodruff School of Mechanical Engineering Georgia Institute of Technology, Atlanta,
7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America
7 Best Practices for Increasing Efficiency, Availability and Capacity XXXX XXXXXXXX Liebert North America Emerson Network Power: The global leader in enabling Business-Critical Continuity Automatic Transfer
Clustering Data Streams
Clustering Data Streams Mohamed Elasmar Prashant Thiruvengadachari Javier Salinas Martin [email protected] [email protected] [email protected] Introduction: Data mining is the science of extracting
Guideline for Water and Energy Considerations During Federal Data Center Consolidations
Guideline for Water and Energy Considerations During Federal Data Center Consolidations Prepared for the U.S. Department of Energy Federal Energy Management Program By Lawrence Berkeley National Laboratory
Convergence is accelerating the path to the New Style of Business
Convergence is accelerating the path to the New Style of Business Paul Durzan Vice President Converged Data Center Infrastructure Hewlett Packard Enterprise Copyright 2012 Hewlett-Packard Development Company,
Information Management course
Università degli Studi di Milano Master Degree in Computer Science Information Management course Teacher: Alberto Ceselli Lecture 01 : 06/10/2015 Practical informations: Teacher: Alberto Ceselli ([email protected])
Data Center Infrastructure Management: How to Optimize Data Center Operations
Data Center Infrastructure Management: How to Optimize Data Center Operations Khaled Nassoura, PE [email protected] General Manager Raritan, Inc. Question of the Day Question: Would any CFO run
Is a Data Scientist the New Quant? Stuart Kozola MathWorks
Is a Data Scientist the New Quant? Stuart Kozola MathWorks 2015 The MathWorks, Inc. 1 Facts or information used usually to calculate, analyze, or plan something Information that is produced or stored by
Georges Da Costa IRIT / Toulouse University GreenDays@Lille 29 11 2013. Green Data Centers: The European Sky
Georges Da Costa IRIT / Toulouse University GreenDays@Lille 29 11 2013 Green Data Centers: The European Sky Key concern in Europe EU climate and energy package 20-20-20 targets A 20% reduction in EU greenhouse
End-to-end management
Brochure End-to-end management HP ProLiant servers with Insight Control Make the most of your investments in servers, staff, and facilities The server management challenge Let s face it. Managing servers
ConSil: Low-cost Thermal Mapping of Data Centers
ConSil: Low-cost Thermal Mapping of Data Centers Justin Moore, Jeffrey S. Chase, and Parthasarathy Ranganathan Duke University Hewlett Packard Labs {justin,chase}@cs.duke.edu [email protected]
How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions
Intel Intelligent Power Management Intel How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions Power and cooling savings through the use of Intel
Dallas/Fort Worth International Airport District Energy Plant Upgrades Project Making More with Less Sustainable Communities Conference Dallas, TX
Dallas/Fort Worth International Airport District Energy Plant Upgrades Project Making More with Less Sustainable Communities Conference Dallas, TX March 10, 2009 Agenda DFW Capital Development Program