EOM-P2RP 2/00 REPLACES EOM-P2RP 6/99
|
|
|
- Alexander Mosley
- 9 years ago
- Views:
Transcription
1 EOM-P2RP 2/00 REPLACES EOM-P2RP 6/99
2 TABLE OF CONTENTS SECTION # PUMP DESIGNATION SYSTEM... SECTION #2 HOW IT WORKS (PUMP & AIR SYSTEMS)... 2 SECTION #3 CAUTIONS... 3 SECTION #4 DIMENSIONAL DRAWING A. Model P2R PLASTIC... 4 SECTION #5 PERFORMANCE CURVES A. Model P2R PLASTIC Rubber-Fitted... 5 B. Model P2R PLASTIC TPE-Fitted... 5 C. Model P2R PLASTIC Teflon -Fitted... 6 SECTION #6 SUCTION LIFT CURVES & DATA... 6 SECTION #7 INSTALLATION AND OPERATION A. Installation... 7 B. Operation & Maintenance... 8 C. Troubleshooting... 9 SECTION #8 DIRECTIONS FOR DISASSEMBLY/REASSEMBLY A. Model P2R PLASTIC Wetted Path Tools Required, Torque Specs, Cautions... 0 B. Pro-Flo Air Valve/Center Block Disassembly, Cleaning, Inspection... 3 C. Reassembly Hints & Tips... 5 D. Teflon Gasket Kit Installation... 6 SECTION #9 EXPLODED VIEW/PARTS LISTING A. Model P2R PLASTIC Rubber/TPE-Fitted... 8 B. Model P2R PLASTIC Teflon -Fitted SECTION #0 ELASTOMER OPTIONS PAGE # NON Class I & II Ozone U.S. Clean Air Act Amendments of 990 USE Depleting Substances
3 SECTION WILDEN PUMP DESIGNATION SYSTEM P2 / XXXX / XX / XX / XXX / (xxx) MODEL O-RINGS VALVE SEAT VALVE BALLS DIAPHRAGMS AIR VALVE CENTER BLOCK OR CENTER SECTION AIR CHAMBERS OR CENTER SECTION WETTED PARTS SPECIALTY CODE (IF APPLICABLE) In the case where a center section is used instead of a center block and air chambers, the designation will be as follows: Polypropylene = PP MODEL P2 PLASTIC MATERIAL CODES WETTED PARTS K = KYNAR/PVDF P = POLYPROPYLENE AIR CHAMBERS L = ACETAL P = POLYPROPYLENE CENTER SECTION L = ACETAL P = POLYPROPYLENE AIR VALVE L = ACETAL P = POLYPROPYLENE DIAPHRAGMS BN = BUNA-N (Red Dot) ET = TEFLON W/INTEGRAL PISTON FG = SANIFLEX ND = NORDEL (Blue Dot) NE = NEOPRENE (Green Dot) PU = POLYURETHANE TF = TEFLON W/NEOPRENE VT = VITON (Silver or White Dot) WF = WIL-FLEX (Orange) VALVE BALL BN = BUNA-N (Red Dot) FG = SANIFLEX FV = FOOD GRADE VITON ND = NORDEL NE = NEOPRENE PU = POLYURETHANE TF = TEFLON PTFE (White) VT = VITON (Silver or White Dot) WF = WIL-FLEX (Orange) VALVE SEAT K = KYNAR/PVDF P = POLYPROPYLENE VALVE SEAT O-RING BN = BUNA-N FG = SANIFLEX ND = NORDEL PU = POLYURETHANE TV = TEFLON ENCAP. VITON WF = WIL-FLEX *O-RINGS NOT REQUIRED. NOTE: ELASTOMERIC MATERIALS USE COLORED DOTS FOR IDENTIFICATION. Buna-N, Nordel and Viton are registered trademarks of DuPont Dow Elastomers. Teflon is a registered trademark of DuPont.
4 SECTION 2 THE WILDEN PUMP HOW IT WORKS The Wilden diaphragm pump is an air-operated, positive displacement, self-priming pump. These drawings show the flow pattern through the pump upon its initial stroke. It is assumed the pump has no fluid in it prior to its initial stroke. OUTLET OUTLET OUTLET CLOSED OPEN OPEN CLOSED OPEN CLOSED B A B A B A OPEN CLOSED CLOSED OPEN CLOSED OPEN INLET INLET INLET RIGHT STROKE MID STROKE LEFT STROKE FIGURE The air valve directs pressurized air to the back side of diaphragm A. The compressed air is applied directly to the liquid column separated by elastomeric diaphragms. The diaphragm acts as a separation membrane between the compressed air and liquid, balancing the load and removing mechanical stress from the diaphragm. The compressed air moves the diaphragm away from the center block of the pump. The opposite diaphragm is pulled in by the shaft connected to the pressurized diaphragm. Diaphragm B is on its suction stroke; air behind the diaphragm has been forced out to the atmosphere through the exhaust port of the pump. The movement of diaphragm B toward the center block of the pump creates a vacuum within chamber B. Atmospheric pressure forces fluid into the inlet manifold forcing the inlet valve ball off its seat. Liquid is free to move past the inlet valve ball and fill the liquid chamber (see shaded area). FIGURE 2 When the pressurized diaphragm, diaphragm A, reaches the limit of its discharge stroke, the air valve redirects pressurized air to the back side of diaphragm B. The pressurized air forces diaphragm B away from the center block while pulling diaphragm A to the center block. Diaphragm B is now on its discharge stroke. Diaphragm B forces the inlet valve ball onto its seat due to the hydraulic forces developed in the liquid chamber and manifold of the pump. These same hydraulic forces lift the discharge valve ball off its seat, while the opposite discharge valve ball is forced onto its seat, forcing fluid to flow through the pump discharge. The movement of diaphragm A toward the center block of the pump creates a vacuum within liquid chamber A. Atmospheric pressure forces fluid into the inlet manifold of the pump. The inlet valve ball is forced off its seat allowing the fluid being pumped to fill the liquid chamber. FIGURE 3 At completion of the stroke, the air valve again redirects air to the back side of diaphragm A, which starts diaphragm B on its exhaust stroke. As the pump reaches its original starting point, each diaphragm has gone through one exhaust and one discharge stroke. This constitutes one complete pumping cycle. The pump may take several cycles to completely prime depending on the conditions of the application. PRO-FLO AIR DISTRIBUTION SYSTEM OPERATION HOW IT WORKS PILOT SPOOL MAIN SHAFT CENTER SECTION MUFFLER PLATE SMALL END END CAP MUFFLER Figure A AIR VALVE SPOOL LARGE END The Pro-Flo patented air distribution system incorporates three moving parts: the air valve spool, the pilot spool, and the main shaft/diaphragm assembly. The heart of the system is the air valve spool and air valve. As shown in Figure A, this valve design incorporates an unbalanced spool. The smaller end of the spool is pressurized continuously, while the large end is alternately pressurized then exhausted to move the spool. The spool directs pressurized air to one air chamber while exhausting the other. The air causes the main shaft/diaphragm assembly to shift to one side discharging liquid on that side and pulling liquid in on the other side. When the shaft reaches the end of its stroke, the inner piston actuates the pilot spool, which pressurizes and exhausts the large end of the air valve spool. The repositioning of the air valve spool routes the air to the other air chamber. 2
5 SECTION 3 WILDEN MODEL P2R PLASTIC CAUTIONS READ FIRST! TEMPERATURE LIMITS: Polypropylene 0 C to 79 C 32 F to 75 F PVDF 2 C to 07 C 0 F to 225 F Neoprene 7.8 C to 93.3 C 0 F to 200 F Buna-N 2.2 C to 82.2 C 0 F to 80 F Nordel 5. C to 37.8 C 60 F to 280 F Viton 40 C to 76.7 C 40 F to 350 F Wil-Flex 40 C to 07.2 C 40 F to 225 F Polyurethane 2.2 C to 65.6 C 0 F to 50 F Saniflex 28.9 C to 04.4 C 20 F to 220 F Teflon PTFE 4.4 C to 48.9 C 40 F to 300 F CAUTION: When choosing pump materials, be sure to check the temperature limits for all wetted components. Example: Viton has a maximum limit of 76.7 C (350 F ) but polypropylene has a maximum limit of only 79 C (75 F). CAUTION: Maximum temperature limits are based upon mechanical stress only. Certain chemicals will significantly reduce maximum safe operating temperatures. Consult engineering guide for chemical compatibility and temperature limits. CAUTION: Always wear safety glasses when operating pump. If diaphragm rupture occurs, material being pumped may be forced out air exhaust. WARNING: Prevention of static sparking If static sparking occurs, fire or explosion could result. Pump, valves, and containers must be properly grounded when handling flammable fluids and whenever discharge of static electricity is a hazard. CAUTION: Do not exceed 8.6 Bar (25 psig) air supply pressure. CAUTION: Champ series pumps are made of virgin plastic and are not UV stabilized. Direct sunlight for prolonged periods can cause deterioration of plastics. CAUTION: Before any maintenance or repair is attempted, the compressed air line to the pump should be disconnected and all air pressure allowed to bleed from pump. Disconnect all intake, discharge and air lines. Drain the pump by turning it upside down and allowing any fluid to flow into a suitable container. CAUTION: Blow out air line for 0 to 20 seconds before attaching to pump to make sure all pipe line debris is clear. Use an in-line air filter. A5µ (micron) air filter is recommended. NOTE: Tighten clamp bands and retainers prior to installation. Fittings may loosen during transportation. NOTE: When installing Teflon diaphragms, it is important to tighten outer pistons simultaneously (turning in opposite directions) to ensure tight fit. NOTE: Before starting disassembly, mark a line from each liquid chamber to its corresponding air chamber. This line will assist in proper alignment during reassembly. CAUTION: Verify the chemical compatibility of the process and cleaning fluid to the pump s component materials in the Chemical Resistance Guide (see RBG E4). CAUTION: When removing the end cap using compressed air, the air valve end cap may come out with considerable force. Hand protection such as a padded glove or rag should be used to capture the end cap. CAUTION: P2R Teflon -fitted pumps come standard from the factory with expaqnded Teflon gaskets. (See Gasket Kit Installation in Section CAUTION: Do not over-tighten the air inlet reducer bushing. Too much torque on the reducer bushing may damage the air valve muffler plate. Do not exceed.9038 m-n (8 in.-lbs.). 3
6 SECTION 4A DIMENSIONAL DRAWING WILDEN MODEL P2R PLASTIC CHAMP 6.35 mm (/4") FNPT AIR INLET A L M B N C P D E S U F J G H T C L mm (/2") FNPT AIR EXHAUST K DIMENSIONS P2R (PLASTIC) ITEM METRIC (mm) STANDARD (inch) A /32 B /32 C /6 D /8 E F /32 G /6 H /32 J /32 K /6 L /6 M /32 N /32 P /6 R 9.5 3/8 DIN ANSI S 42.9 RAD. 9/6 RAD. T 57.2 RAD. 2 /8 RAD. U 4.3 DIA. 5/8 DIA. R FLANGE 4
7 Discharge Pressure Discharge Pressure SECTION 5A PERFORMANCE CURVES MODEL P2R PLASTIC RUBBER-FITTED Height mm (4" ) Width mm ( 2 32") Depth mm (9 3 32") Ship Weight...Polypropylene 8.26 kg (8 lbs.) PVDF 0.4 kg (23 lbs.) Air Inlet mm ( 4") Inlet mm (") Outlet mm (") Suction Lift m Dry (8') 8.84 m Wet (29') Displacement per Stroke....3 l (.082 gal.) Max. Flow Rate lpm (37 gpm) Max. Size Solids...(3.8 mm ( 8") Displacement per stroke was calculated at 4.8 Bar (70 psig) air inlet pressure against a 2 Bar (30 psig) head pressure. Example: To pump 68. lpm (8 gpm) against a discharge pressure head of 2.7 Bar (40 psig) requires 4. Bar (60 psig) and 2.9 Nm 3 /h (3 scfm) air consumption. (See dot on chart.) Caution: Do not exceed 8.6 Bar (25 psig) air supply pressure. BAR FEET PSIG GPM [l/min] (0) [7] (20) [34] (30) [5] (40) [68] [9] [38] [57] [76] [95] [4] [33] [5] Water Discharge Flow Rates AIR CONSUMPTION (SCFM) [Nm 3 /h] Flow rates indicated on chart were determined by pumping water. For optimum life and performance, pumps should be specified so that daily operation parameters will fall in the center of the pump performance curve. SECTION 5B PERFORMANCE CURVES MODEL P2R PLASTIC TPE-FITTED Height mm (4") Width mm ( 2 32") Depth mm (9 3 32") Ship Weight...Polypropylene 8.26 kg (8 lbs.) PVDF 0.4 kg (23 lbs.) Air Inlet mm ( 4") Inlet mm (") Outlet mm (") Suction Lift m Dry (8') 8.84 m Wet (29') Displacement per Stroke l (0.04 gal.) Max. Flow Rate lpm (37 gpm) Max. Size Solids mm ( 8" ) Displacement per stroke was calculated at 4.8 Bar (70 psig) air inlet pressure against a 2 Bar (30 psig) head pressure. Example: To pump 68. lpm (8 gpm) against a discharge pressure head of 2.7 Bar (40 psig) requires 4. Bar (60 psig) and 8.59 Nm 3 /h ( scfm) air consumption. (See dot on chart.) Caution: Do not exceed 8.6 Bar (25 psig) air supply pressure. BAR FEET PSIG GPM [l/min] (0) [7] (20) [34] (30) [5] (40) [68] [9] [38] [57] [76] [95] [4] [33] [5] Water Discharge Flow Rates AIR CONSUMPTION (SCFM) [Nm 3 /h] Flow rates indicated on chart were determined by pumping water. For optimum life and performance, pumps should be specified so that daily operation parameters will fall in the center of the pump performance curve. 5
8 Dry Vacuum Discharge Pressure SECTION 5C PERFORMANCE CURVES MODEL P2R PLASTIC TEFLON -FITTED Height mm (4") Width mm ( 2 32") Depth mm (9 3 32") Ship Weight...Polypropylene 8.26 kg (8 lbs.) PVDF 0.4 kg (23 lbs.) Air Inlet mm ( 4") Inlet mm (") Outlet mm (") Suction Lift m Dry (') 8.84 m Wet (29') Displacement per Stroke l (0.06 gal.) Max. Flow Rate lpm (35 gpm) Max. Size Solids mm ( 8") Displacement per stroke was calculated at 4.8 Bar (70 psig) air inlet pressure against a 2 Bar (30 psig) head pressure. Example: To pump 68. lpm (8 gpm) against a discharge pressure head of 2.7 Bar (40 psig) requires 4. Bar (60 psig) and 37.8 Nm 3 /h (22 scfm) air consumption. (See dot on chart.) Caution: Do not exceed 8.6 Bar (25 psig) air supply pressure. SECTION 6 SUCTION LIFT CURVES & DATA Meter FT H 2 O PSIG [BAR] BAR FEET Flow rates indicated on chart were determined by pumping water. For optimum life and performance, pumps should be specified so that daily operation parameters will fall in the center of the pump performance curve. P2R Plastic Suction Lift Capability Teflon Diaphragms PSIG TPE Diaphragms (0) [7] 0 GPM [l/min] (20) [34] (30) [5] (40) [68] Traditional Rubber Diaphragms Water Discharge Flow Rates [.7] [.4] [2] [2.7] [3.4] [4.] [4.8] [5.5] [6.2] [6.9] Inlet Air Pressure AIR CONSUMPTION (SCFM) [Nm 3 /h] [9] [38] [57] [76] [95] [4] [33] [5] Suction lift curves are calibrated for pumps operating at 305 m (,000') above sea level. This chart is meant to be a guide only. There are many variables which can affect your pump s operating characteristics. The number of intake and discharge elbows, viscosity of pumping fluid, elevation (atmospheric pressure) and pipe friction loss all affect the amount of suction lift your pump will attain. 6
9 SECTION 7A INSTALLATION The Pro-Flo model P2R has a 25.4 mm (") inlet and 25.4 mm (") outlet and is designed for flows to lpm (37 gpm). The P2R Champ pump is manufactured with wetted parts of pure, unpigmented PVDF or polypropylene. The P2R Champ is constructed with a polypropylene or acetal center section. A variety of diaphragms and O-rings are available to satisfy temperature, chemical compatibility, abrasion and flex concerns. The suction pipe size should be at least 25.4 mm (") diameter or larger if highly viscous material is being pumped. The suction hose must be non-collapsible, reinforced type as the P2R is capable of pulling a high vacuum. Discharge piping should be at least 25.4 mm ("); larger diameter can be used to reduce friction losses. It is critical that all fittings and connections are airtight or a reduction or loss of pump suction capability will result. INSTALLATION: Months of careful planning, study, and selection efforts can result in unsatisfactory pump performance if installation details are left to chance. Premature failure and long term dissatisfaction can be avoided if reasonable care is exercised throughout the installation process. LOCATION: Noise, safety, and other logistical factors usually dictate where equipment be situated on the production floor. Multiple installations with conflicting requirements can result in congestion of utility areas, leaving few choices for additional pumps. Within the framework of these and other existing conditions, every pump should be located in such a way that five key factors are balanced against each other to maximum advantage. ACCESS: First of all, the location should be accessible. If it s easy to reach the pump, maintenance personnel will have an easier time carrying out routine inspections and adjustments. Should major repairs become necessary, ease of access can play a key role in speeding the repair process and reducing total downtime. AIR SUPPLY: Every pump location should have an air line large enough to supply the volume of air necessary to achieve the desired pumping rate (see Section 5). Use air pressure up to a maximum of 8.6 Bar (25 psi) depending on pumping requirements. For best results, the pumps should use a 5 micron air filter, needle valve and regulator. The use of an air filter before the pump will insure that the majority of any pipeline contaminants will be eliminated. SOLENOID OPERATION: When operation is controlled by a solenoid valve in the air line, three-way valves should be used, thus allowing trapped air to bleed off and improving pump performance. Pumping volume can be set by counting the number of strokes per minute and multiplying by displacement per stroke. Sound levels are reduced below OSHA specifications using the standard Wilden muffler element. Other mufflers can be used but usually reduce pump performance. ELEVATION: Selecting a site that is well within the pump s dynamic lift capability will assure that loss-of-prime troubles will be eliminated. In addition, pump efficiency can be adversely affected if proper attention is not given to site location. PIPING: Final determination of the pump site should not be made until the piping problems of each possible location have been evaluated. The impact of current and future installations should be considered ahead of time to make sure that inadvertent restrictions are not created for any remaining sites. The best choice possible will be a site involving the shortest and straightest hook-up of suction and discharge piping. Unnecessary elbows, bends, and fittings should be avoided. Pipe sizes should be selected so as to keep friction losses within practical limits. All piping should be supported independently of the pump. In addition, the piping should be aligned so as to avoid placing stresses on the pump fittings. Flexible hose can be installed to aid in absorbing the forces created by the natural reciprocating action of the pump. If the pump is to be bolted down to a solid location, a mounting pad placed between the pump and the foundation will assist in minimizing pump vibration. Flexible connections between the pump and rigid piping will also assist in minimizing pump vibration. If quick-closing valves are installed at any point in the discharge system, or if pulsation within a system becomes a problem, a surge suppressor should be installed to protect the pump, piping and gauges from surges and water hammer. The P2R can be installed in submersible applications only when both the wetted and non-wetted portions are compatible with the material being pumped. If the pump is to be used in a submersible application, a hose should be attached to the pump s air and pilot spool exhaust ports and piped above the liquid level. The exhaust area for the pilot spool is designed to be tapped for a 8" NPT fitting. When pumps are installed in applications involving flooded suction or suction head pressures, a gate valve should be installed in the suction line to permit closing of the line for pump service. If the pump is to be used in a self-priming application, be sure that all connections are airtight and that the suction lift is within the model s ability. Note: Materials of construction and elastomer material have an effect on suction lift parameters. Please consult Wilden distributors for specifics. Pumps in service with a positive suction head are most efficient when inlet pressure is limited to.5.7 Bar (7 0 psig). Premature diaphragm failure may occur if positive suction is 0 psig and higher. THE MODEL P2R CHAMP WILL PASS 3.8 MM ( 8") SOLIDS. WHENEVER THE POSSIBILITY EXISTS THAT LARGER SOLID OBJECTS MAY BE SUCKED INTO THE PUMP, A STRAINER SHOULD BE USED ON THE SUCTION LINE. CAUTION: DO NOT EXCEED 8.6 BAR (25 PSIG) AIR SUPPLY PRESSURE. 7
10 SUGGESTED INSTALLATION COMBINATION FILTER & REGULATOR FLEXIBLE CONNECTION GAUGE (OPTIONAL) SHUT OFF VALVE AIR SHUT OFF VALVE NEEDLE VALVE PIPE CONNECTION (STYLE OPTIONAL) EQUALIZER SURGE DAMPENER (OPTIONAL) DISCHARGE MUFFLER SUCTION AIR-OPERATED PUMPS: To stop the pump from operating in an emergency situation, simply close the shut-off valve (user supplied) installed in the air supply line. A properly functioning valve will stop the air supply to the pump, therefore stopping output. This shut-off valve should be located far enough away from the pumping equipment such that it can be reached safely in an emergency situation. NOTE: In the event of a power failure, the shutoff valve should be closed, if the restarting of the pump is not desirable once power is regained. SECTION 7B SUGGESTED OPERATION AND MAINTENANCE INSTRUCTIONS OPERATION: Pump discharge rate can be controlled by limiting the volume and/or pressure of the air supply to the pump (preferred method). An air regulator is used to regulate air pressure. A needle valve is used to regulate volume. Pump discharge rate can also be controlled by throttling the pump discharge by partially closing a valve in the discharge line of the pump. This action increases friction loss which reduces flow rate. This is useful when the need exists to control the pump from a remote location. When the pump discharge pressure equals or exceeds the air supply pressure, the pump will stop; no bypass or pressure relief valve is needed, and pump damage will not occur. The pump has reached a deadhead situation and can be restarted by reducing the fluid discharge pressure or increasing the air inlet pressure. The Wilden P2R pump runs solely on compressed air and does not generate heat, therefore your process fluid temperature will not be affected. RECORDS: When service is required, a record should be made of all necessary repairs and replacements. Over a period of time, such records can become a valuable tool for predicting and preventing future maintenance problems and unscheduled downtime. In addition, accurate records make it possible to identify pumps that are poorly suited to their applications. MAINTENANCE AND INSPECTIONS: Since each application is unique, maintenance schedules may be different for every pump. Frequency of use, line pressure, viscosity and abrasiveness of process fluid all affect the parts life of a Wilden pump. Periodic inspections have been found to offer the best means for preventing unscheduled pump downtime. Personnel familiar with the pump s construction and service should be informed of any abnormalities that are detected during operation. 8
11 SECTION 7C TROUBLESHOOTING Pump will not run or runs slowly.. Ensure that the air inlet pressure is at least.35 Bar (5 psig) above startup pressure and that the differential pressure (the difference between air inlet and liquid discharge pressures) is not less than.7 Bar (0 psig). 2. Check air inlet filter for debris (see recommended installation). 3. Check for extreme air leakage (blow by) which would indicate worn seals/bores in the air valve, pilot spool, main shaft. 4. Disassemble pump and check for obstructions in the air passageways or objects which would obstruct the movement of internal parts. 5. Check for sticking ball check valves. If material being pumped is not compatible with pump elastomers, swelling may occur. Replace ball check valves and seals with proper elastomers. Also, as the check valve balls wear out, they become smaller and can become stuck in the seats. In this case, replace balls and seats. 6. Check for broken inner piston which will cause the air valve spool to be unable to shift. 7. Remove plug from pilot spool exhaust. Pump runs but little or no product flows.. Check for pump cavitation; slow pump speed down to allow thick material to flow into liquid chambers. 2. Verify that vacuum required to lift liquid is not greater than the vapor pressure of the material being pumped (cavitation). 3. Check for sticking ball check valves. If material being pumped is not compatible with pump elastomers, swelling may occur. Replace ball check valves and seals with proper elastomers. Also, as the check valve balls wear out, they become smaller and can become stuck in the seats. In this case, replace balls and seats. Pump air valve freezes.. Check for excessive moisture in compressed air. Either install a dryer or hot air generator for compressed air. Alternatively, a coalescing filter may be used to remove the water from the compressed air in some applications. Air bubbles in pump discharge.. Check for ruptured diaphragm. 2. Check tightness of outer pistons (refer to Section 8C). 3. Check tightness of clamp bands and integrity of O-rings and seals, especially at intake manifold. 4. Ensure pipe connections are airtight. Product comes out air exhaust.. Check for diaphragm rupture. 2. Check tightness of outer pistons to shaft. 9
12 SECTION 8A MODEL P2R PLASTIC DIRECTIONS FOR DISASSEMBLY/REASSEMBLY CAUTION: Before any maintenance or repair is attempted, the compressed air line to the pump should be disconnected and all air pressure allowed to bleed from the pump. Disconnect all intake, discharge, and air lines. Drain the pump by turning it upside down and allowing any fluid to flow into a suitable container. Be aware of any hazardous effects of contact with your process fluid. The Wilden model P2R has a 25.4 mm (") inlet and 25.4 mm (") outlet and is designed for flows up to lpm (37 gpm). The wetted path comes in both PVDF and polypropylene. The single-piece center section, consisting of center block and air chambers, is molded of polypropylene or acetal. The air valve body is manufactured of acetal or polypropylene. All O-rings used in the pump are of a special material and shore hardness that should only be replaced with factory-supplied parts. TOOLS REQUIRED: 2" Box Wrench 2" Socket 2" Socket Drive 2 " Sockets or Adjustable Wrench Adjustable Wrench Vise equipped with soft jaws (such as plywood, plastic or other suitable material) NOTE: The model used for these instructions incorporates rubber diaphragms, balls, and seats. Models with Teflon diaphragms, balls and seats are the same except where noted. DISASSEMBLY: Figure Step. Before starting disassembly, mark a line from each liquid chamber to its corresponding air chamber. This line will assist in proper alignment during reassembly. (Figure ) Step 2. Figure 2 Using a screwdriver or other long, slim object, loosen the top liquid retainers from the liquid chambers. (Figure 2) Step 3. Figure 3 Remove the top liquid retainer to expose the valve balls, valve seats and valve seat O-rings. (Figure 3) 0
13 Step 4. Figure 4 Remove the top liquid retainer and retainer O-rings, discharge valve balls, seats and valve seat O-rings from the liquid chamber and inspect for nicks, gouges, chemical attack or abrasive wear. Replace worn parts with genuine Wilden parts for reliable performance. (Figure 4) Step 5. Figure 5 Using a 2" socket driver, loosen the bottom retainers. (Figure 5) Step 6. Figure 6 Remove the bottom liquid retainer and retainer O-rings, discharge valve balls, seats and valve seat O-rings from the liquid chamber and inspect for nicks, gouges, chemical attack or abrasive wear. Replace worn parts with genuine Wilden parts for reliable performance. (Figure 6) Step 7. Figure 7 With a 2" box wrench, loosen the large clamp bands that secure the liquid chambers to the center section. (Figure 7) Step 8. Figure 8 Rotate the clamp bands so that they can be removed. (Figure 8)
14 Step 9. Figure 9 After clamp bands are removed, pull liquid chambers apart. (Figure 9) Step 0. Figure 0 Remove tee section from liquid chamber and inspect O-rings for signs of wear. Replace worn parts with genuine Wilden parts for reliable performance. (Figure 0) Step. Figure Using two " sockets, remove diaphragm assembly from center section assembly. (Figure ) Step 2. Figure 2 To remove the remaining diaphragm assembly from the shaft, secure shaft with soft jaws (a vise fitted with plywood or other suitable material) to ensure shaft is not nicked, scratched, or gouged. Using an adjustable wrench, remove diaphragm assembly from shaft. Inspect all parts for wear and replace with genuine Wilden parts if necessary. (Figure 2) Step 3. Figure 3 Inspect diaphragms, outer and inner pistons and disc spring (not shown) for signs of wear. Replace with genuine Wilden parts if necessary. 2
15 SECTION 8B PRO-FLO AIR VALVE/CENTER SECTION DISASSEMBLY, CLEANING, INSPECTION AIR VALVE DISASSEMBLY: CAUTION: Before any maintenance or repair is attempted, the compressed air line to the pump should be disconnected and all air pressure allowed to bleed from the pump. Disconnect all intake, discharge, and air lines. Drain the pump by turning it upside down and allowing any fluid to flow into a suitable container. Be aware of hazardous effects of contact with your process fluid. The Wilden Plastic P2 utilizes a revolutionary Pro-Flo air distribution system. A 6.35 mm ( 4") air inlet connects the air supply to the center section. Proprietary composite seals reduce the coefficient of friction and allow the P2 to run lubefree. Constructed of acetal or polypropylene, the Pro-Flo air distribution system is designed to perform in on/off, non-freezing, non-stalling, tough duty applications. TOOLS REQUIRED: 3 6" Hex Head Wrench Snap Ring Pliers O-Ring Pick Step. Figure Loosen the air valve bolts utilizing a 3 6" hex head wrench. (Figure ) Step 2. Figure 2 Remove muffler plate and air valve bolts from air valve assembly (Figure 2) exposing muffler gasket for inspection. Replace if necessary. Step 3. Figure 3 Lift away air valve assembly and remove air valve gasket for inspection (Figure 3). Replace if necessary. Step 4. Figure 4 Remove air valve end cap to expose air valve spool by simply lifting up on end cap once air valve bolts are removed. (Figure 4). 3
16 Step 5. Figure 5 Remove air valve spool from air valve body by threading one air valve bolt into the end of the spool and gently sliding the spool out of the air valve body (Figure 5). Inspect seals for signs of wear and replace entire assembly if necessary. Use caution when handling air valve spool to prevent damaging seals. NOTE: Seals should not be removed from assembly. Seals are not sold separately. Step 6. Figure 6 Remove pilot spool sleeve retaining snap ring on both sides of center section with snap ring pliers (Figure 6). Step 7. Figure 7 Remove pilot spool sleeve from center section (Figure 7). Step 8. Figure 8 With O-ring pick, gently remove pilot spool retaining O-ring (Figure 8). Replace if necessary. Gently remove pilot spool from sleeve and inspect spool and seals for nicks, gouges or other signs of wear. Replace pilot sleeve assembly or outer sleeve O-rings if necessary. NOTE: Seals should not be removed from pilot spool. Seals are not sold separately. Step 9. Figure 9 Check center section Glyd rings for signs of wear. If necessary, remove Glyd rings with O-ring pick and replace. (Figure 9) 4
17 SECTION 8C REASSEMBLY HINTS & TIPS ASSEMBLY: Upon performing applicable maintenance to the air distribution system, the pump can now be reassembled. Please refer to the disassembly instructions for photos and parts placement. To reassemble the pump, follow the disassembly instructions in reverse order. The air distribution system needs to be assembled first, then the diaphragms and finally the wetted path. Please find the applicable torque specifications on this page. The following tips will assist in the assembly process. Clean the inside of the center section shaft bore to ensure no damage is done to new seals. Stainless bolts should be lubed to reduce the possibility of seizing during tightening. Be sure to tighten outer pistons simultaneously on Teflon - fitted pumps to ensure proper torque values. Apply a small amount of Loctite 242 to the shaft interval threads before the diaphragm assembly. Concave side of disc spring in diaphragm assembly faces toward inner piston. MAXIMUM TORQUE SPECIFICATIONS Description of Part Plastic Pumps Air Valve, Pro-Flo 3.05 m-n [27 in.-lbs.] Air Inlet, Reducer Bushing.9038 m-n [8 ft.-lbs.] Outer Piston Rubber- and Teflon -fitted 33.9 m-n [20 ft.-lbs.] Top and Bottom Retainers 4. m-n [25 in.-lbs.] Large Clamp Band Rubber-fitted 0.7 m-n [95 in.-lbs.] Large Clamp Band Teflon -fitted 4. m-n [25 in.-lbs.] 5
18 SECTION 8D GASKET KIT INSTALLATION Teflon -fitted P2R pumps require expanded Teflon material around the diaphragm bead (P/N ). Carefully prepare sealing surfaces by removing all debris and foreign matter from diaphragm bead and all mating surfaces. If necessary, smooth or deburr all sealing surfaces. Mating surfaces must be properly aligned in order to ensure positive sealing characteristics. Step. Figure Gently remove the adhesive covering from the back of the Teflon tape. Ensure that the adhesive strip remains attached to the Teflon tape. Step 2. Figure 2 Starting at any point, place the Teflon tape in the center of the diaphragm bead groove on the liquid chamber and press lightly on the tape to ensure that the adhesive holds it in place during assembly. Do not stretch the tape during placement in center of diaphragm bead groove. Step 3. Figure 3 The ends of the tape should overlap approximately.27 cm ( 2 ) (Figure 3). Proceed to install the Teflon tape on the remaining liquid chamber. 6
19 MAINTENANCE RECORD DATE SERVICE RENDERED SERVICED BY 7
20 SECTION 9A EXPLODED VIEW/PARTS LISTING P2R PLASTIC CHAMP RUBBER- FITTED
21 MODEL P2R PLASTIC RUBBER/TPE-FITTED Qty. P2/ P2/ P2/ P2/ Per PPPP-400 PPPP-402 KPPP-400 KPPP-402 Item Part Description Pump P/N P/N P/N P/N Pro-Flo Air Valve Assembly End Cap O-Ring, End Cap Gasket, Air Valve Screw, HSHC, Air Valve Nut, Hex, 4" Center Section Bushing, Reducer Removable Pilot Sleeve Assembly Glyd Ring II Retaining Ring Muffler Plate Gasket, Muffler Plate Muffler Shaft, Pro-Flo Disc Spring (Belleville Washer) Inner Piston Outer Piston Liquid Chamber Manifold Tee Section Top Retainer Bottom Retainer T-Section O-Ring 4 * * * * 24 Top Retainer O-Ring 2 * * * * 25 Bottom Retainer O-Ring 2 * * * * 26 Diaphragm 2 * * * * 27 Valve Ball 4 * * * * 28 Valve Seat Valve Seat O-Ring 4 * * * * 30 Clamp Band Assembly Clamp Band Bolt 5 6" 8 x 3 4" Clamp Band Nut 5 6" Air Valve Assembly includes items 2 and 3. *Refer to corresponding elastomer chart in Section Specialty Code = P2R Champ -402 Specialty Code = P2R Champ with Teflon PFA coating All boldface items are primary wear parts. 9
22 SECTION 9B EXPLODED VIEW/PARTS LISTING P2R PLASTIC CHAMP TEFLON - FITTED
23 MODEL P2R PLASTIC TEFLON -FITTED Qty. P2/ P2/ P2/ P2/ Per PPPP-400 PPPP-402 KPPP-400 KPPP-402 Item Part Description Pump P/N P/N P/N P/N Pro-Flo Air Valve Assembly End Cap O-Ring, End Cap Gasket, Air Valve Screw, HSHC, Air Valve Nut, Hex, 4" Center Section Bushing, Reducer Removable Pilot Sleeve Assembly Glyd Ring II Retaining Ring Muffler Plate Gasket, Muffler Plate Muffler Shaft, Pro-Flo Disc Spring (Belleville Washer) Inner Piston Outer Piston Liquid Chamber Manifold Tee Section Top Retainer Bottom Retainer T-Section O-Ring Top Retainer O-Ring Bottom Retainer O-Ring Diaphragm Backup Diaphragm Valve Ball Valve Seat Valve Seat O-Ring Clamp Band Assembly Clamp Band Bolt 5 6" 8 x 3 4" Clamp Band Nut 5 6" Air Valve Assembly includes items 2 and 3. *Refer to corresponding elastomer chart in Section Specialty Code = P2R Champ -402 Specialty Code = P2R Champ with Teflon PFA coating All boldface items are primary wear parts. 2
24 SECTION 0A ELASTOMER OPTIONS ELASTOMER OPTIONS FOR MODEL P2R CHAMP PUMPS Color Diaphragm Valve Ball Valve Seat Tee Section Top Retainer Bottom Retainer Material Code P/N (2) P/N (4) O-Ring P/N (4) O-Ring P/N (4) O-Ring P/N (4) O-Ring P/N (4) Polyurethane Natural Buna-N Red Teflon Encapsulated Viton None N/A N/A Neoprene Green N/A N/A N/A N/A Viton Silver N/A N/A N/A N/A Nordel Blue N/A N/A N/A N/A Teflon White N/A N/A N/A N/A Saniflex Off-White N/A N/A N/A N/A Wil-Flex Orange Neoprene Backup Black N/A N/A N/A N/A N/A Saniflex back-up diaphragms, P/N , are available upon request. Please consult your local distributor. 22
25 NOTES
26 NOTES
27
28 Revolutionizing the way you solve your toughest pumping problems Plastic Polypropylene Carbon-Filled Acetal PVDF Teflon PTFE Teflon PFA Metal Aluminum 36 S.S. Cast Iron Hastelloy FDA USDA 3A Teflon PFA Teflon PTFE Van Buren St., Grand Terrace, CA Telephone (909) Fax (909) Your local authorized distributor: Accessories SPCI FCSI Drum Pump Kits Wil-Gard Equalizers APV PRINTED IN THE U.S.A.
300 SERIES 331, 332, 333, 344, 356 AND 367 MODELS
Section: MOYNO 500 PUMPS Page: 1 of 8 Date: March 1, 1998 SERVICE MANUAL MOYNO 500 PUMPS 300 SERIES 331, 332, 333, 344, 356 AND 367 MODELS Mechanical Seal Models Packing Gland Models MODELS DESIGN FEATURES
Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components
Schematic Throttles to reduce high upstream pressure to constant lower downstream pressure Throttles to maintain minimum upstream pressure PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE
Float and Thermostatic Traps Series H, C and X
Hoffman Specialty Installation & Maintenance Instructions HS-(E) and Thermostatic Traps Series H, C and X Series C & NPT Series C NPT Series X NPT Series C NPT Series H Ratings Maximum Max. Operating NPT
PRESSURE REDUCING CONTROL VALVE
Schematics Throttles to reduce high upstream pressure to constant lower downstream pressure Low Flow By-Pass controls at low flows 4 PRESSURE REDUCING CONTROL VALVE with LOW FLOW BY-PASS FEATURE Main Line
Round Housing with Side Ports
Power Steering Steering Control Unit (SCU) Parts and Repair Information 5 Series Steering Control Units 001 Square Housing with Side Ports Round Housing with Side Ports T E L RP Round Housing with End
Table of Contents. Overview 1. Pump Disassembly 2. Control Disassembly / Reassembly 7. Pump Reassembly 13. Adjustment Procedures DR Control 19
Table of Contents Overview 1 Pump Disassembly 2 Control Disassembly / Reassembly 7 Pump Reassembly 13 Adjustment Procedures DR Control 19 Adjustment Procedures DRG Control 20 Adjustment Procedures DFR
STEERING SYSTEM - POWER
STEERING SYSTEM - POWER 1990 Nissan 240SX 1990 STEERING Nissan - Power Rack & Pinion Axxess, Maxima, Pulsar NX, Sentra, Stanza, 240SX, 300ZX DESCRIPTION The power steering system consists of a rack and
Unit: mm(in) Item Standard value Service limit Axle shaft run out - 0.2(0.008)
Rear Wheel/Brake/Suspension 13. Rear Wheel/Brake/Suspension Service Information 13-1 Troubleshooting 13-2 Rear Wheel 13-3 Rear Cushion 13-4 Rear Swing Arm 13-7 Service Information General Safety If the
Installation and Operating Instructions Installation Instructions for SS EPE-316L Series
INSTR3010 0406 Installation and Operating Instructions Installation Instructions for SS EPE-316L Series Congratulations on your purchase of this Aqua-Pure high flow, single housing filtration system. This
BOWIE PUMPS OPERATION - MAINTENANCE
BOWIE PUMPS OPERATION - MAINTENANCE PUMPING PRINCIPLE: The meshing owieeof the gears cause a slight depression, with the resulting enmeshing of the gears causing a vacuum drawing the fluid being pumped
SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)
APPLICATIONS Process Industry Weak Acids Alkalies Compressed Air Pulp & Paper MODELS ASM - Flanged Connection OPTIONS Control Rods Oil & Gas Water & Waste Pump suction & discharge Sea water Chemical lines
NDP-50 Specifications
NDP-50 Specifications Port Dimensions Intake & discharge connection: (164 GPM Max.) Polypropylene (PPG) 2" ANSI B16.5 #150 Kynar (PVDF) 2" ANSI B16.5 #150 Aluminum (ADC-12) 2" ANSI B16.5 #150 (with tapped
Char-Lynn Spool Valve Hydraulic Motors. Repair Information. W Series Geroler Motors
Char-Lynn Spool Valve Hydraulic Motors Repair Information W Series Geroler Motors with Parking Brake 004 Nut Key Ring, Retaining Bearing Ring, Retaining Ring, Retaining Washer (Thick), Pressure Washer,
TYPE E Main Valve Sizes 3 /8 through 12
SD 3001F PRINTED IN U.S.A. SD 3001F/0707 A B TYPE E MAIN VALVE C D E TYPE E Main Valve Sizes 3 /8 through 12 The Spence Type E Main Valve is of normally closed, single seat design featuring packless construction,
Graymills. Air Operated Double Diaphragm Pumps. Operations and Maintenance Instructions
795 08690 GM 12 00 Graymills Air Operated Double Diaphragm Pumps Operations and Maintenance Instructions /S Read all these SAFETY INSTRUCTIONS BEFORE installing or using this equipment. Keep this manual
Char-Lynn Hydraulic Motor. Repair Information. 10 000 Series. October, 1997
Char-Lynn Hydraulic Motor October, 1997 Repair Information Geroler Motor Two Speed 001 27 Retainer inside bore of valve plate bearingless motors only 4 15 16 3 6 35 Parts Drawing 25 2 2 1 19 17 36 40 47
Stainless Steel Single and Dual Circulation Kits
Instruction Sheet P/N 160780 01 Stainless Steel Single and Dual Circulation Kits Introduction The single and dual high-pressure circulation kits allow you to vary and control the circulation rate of coating
Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description
Product Manual CVS Type 67AFR Filter Regulator Introduction This CVS Controls product manual includes instructions for the installation, adjustment, maintenance and parts ordering of the CVS Type 67AFR
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE
DeZURIK 3-20" BAW AWWA BUTTERFLY VALVES WITH TRANSFER MOLDED SEAT
3-20" BAW AWWA BUTTERFLY VALVES WITH TRANSFER MOLDED SEAT Instruction D10386 August 2013 Instructions These instructions provide installation, operation and maintenance information for BAW Butterfly Valves.
IF IT FLOWS THE BOWIE PUMP CAN PUMP IT
IF IT FLOWS THE BOWIE PUMP CAN PUMP IT Bowie Industries, Inc. Bowie, TX 76230 USA Page 1 Bowie Pumps Manual General Pump Information..Page 2 300 Series Pumps.. Page 5 400 Series Pumps.Page 11 500 Series
ENGINE FUEL FUEL FILTER... FUEL HEATER... INJECTOR... SUPPLY PUMP... COMMON RAIL... FUEL PRESSURE LIMITTER...
FUEL FILTER............................ FUEL HEATER.......................... INJECTOR.............................. SUPPLY PUMP.......................... COMMON RAIL.......................... FUEL PRESSURE
For exploded diagram and part number information, refer to the Spare Parts Catalog available on our website at www.rockshox.com.
For exploded diagram and part number information, refer to the Spare Parts Catalog available on our website at www.rockshox.com. Information contained in this publication is subject to change at anytime
Pipe Valves, Fittings and Nipples Pressures to 15,200 psi
Pipe Valves, Fittings and Nipples MAXIMATOR has been designing and manufacturing high pressure equipment for more than thirty years and has a worldwide reputation for quality and reliability, backed by
ALMATEC Series CX CX 10 CX 130
ALMATEC Series CX CX 10 CX 130 Operating and Installation Instructions ought to be studied before installing the pump The ALMATEC Maschinenbau GmbH is certified as a modern, quality-orientated enterprise
Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW
Installation, Operating and Maintenance Instructions 90/4.5.5 Rev. 0 Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW Table of Contents SECTION I... 2 INSTALLATION...
with installation dynafact boost GAUGE this manual is for use with systems 64050-64054
owners manual with installation instructions dynafact boost GAUGE this manual is for use with systems 64050-64054 GENERAL INSTALLATION PRACTICES This manual is an installation guide for all 1. Banks DynaFact
STORAGE, INSTALLATION AND MAINTENANCE PROCEDURES
GATE VALVE O.S. & Y 1.0 Periodic Inspections 1.1 The valve stem packing should be inspected at least monthly. If the stem packing shows signs of leakage, simply tighten the adjusting nuts to compress the
Submersion/Insertion Toroidal Sensor
Instruction Sheet PN 51A-228/rev.P December 2010 Model 228 Submersion/Insertion Toroidal Sensor For additional information, please visit our website at www.emersonprocess.com/raihome/liquid/. CAUTION SENSOR/PROCESS
For exploded diagram and part number information, refer to the Spare Parts Catalog available on our website at www.rockshox.com.
For exploded diagram and part number information, refer to the Spare Parts Catalog available on our website at www.rockshox.com. 2 0 0 5 D U K E A I R X C / S L / R A C E S E R V I C E G U I D E Information
Toroidal Conductivity Sensor
Instruction Sheet PN 51A-/rev.C June 2012 Toroidal Conductivity Sensor For additional information, please visit our website at www.emersonprocess.com/rosemountanalytical.com SPECIFICATIONS Wetted Materials:
Trash Pumps Models: 56200, 562000, 56201, 562001, 56300, 563000, 56301, 563001
Trash Pumps Models: 56200, 562000, 56201, 562001, 56300, 563000, 56301, 563001 Specifically designed pumps for heavy duty applications Handles solids with eas and simple to open and clean Standard roll
Owner s Manual. Models: 2S5P & 3S5P OPERATION AND MAINTENANCE OF SELF-PRIMING CENTRIFUGAL TRASH PUMPS PEDESTAL DRIVE
Owner s Manual Models: 2S5P & 3S5P OPERATION AND MAINTENANCE OF SELF-PRIMING CENTRIFUGAL TRASH PUMPS PEDESTAL DRIVE WARNING!! Installation & Operating Instructions Self-Priming Centrifugal Pump DO NOT
Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation
Instruction Manual 1052 Size 20 Actuator (F & G) Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation Contents Introduction... 1 Scope of manual... 1 Description... 1 Specifications...
OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS. INTRODUCTION...1 Scope...1 Description...1 Valve Identification...
OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS INTRODUCTION...1 Scope...1 Description...1 Valve Identification...2 1.0 VALVE INSTALLATION...2 2.0 VALVE MAINTENANCE...3 Actuator Disassembly...3
Chapter 7 Hydraulic System Troubleshooting
Chapter 7 Hydraulic System Troubleshooting General The following troubleshooting information is provided as a general guide to identify, locate and correct problems that may be experienced with the hydraulic
IMPORTANT DOCUMENTATION DO NOT DISCARD!
PART NO.: 6441-263C SERIES GRT 3 JAW PARALLEL GRIPPERS INFORMATION SHEET IMPORTANT DOCUMENTATION DO NOT DISCARD! Use this information sheet to assist with gripper installation and setup. File with maintenance
RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description
Worldwide Contacts www.tyco-fire.com RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description The TYCO RAPID
Rebuild Instructions for 70001 and 70010 Transmission
Rebuild Instructions for 70001 and 70010 Transmission Brinn, Incorporated 1615 Tech Drive Bay City, MI 48706 Telephone 989.686.8920 Fax 989.686.6520 www.brinninc.com Notice Read all instructions before
PVM Piston Pumps Service Manual
PVM Piston Pumps Service Manual PVM018/020 PVM045/050 PVM057/063 PVM074/081 PVM098/106 PVM131/141 Table of Contents Service Parts Pump Description... 3 Basic pump Pump Operation Controls Types Part Identification...
Dive Rite 200 & 300 Bar Isolator Manifold Service Manual
Dive Rite 200 & 300 Bar Isolator Manifold Service Manual Principal Photography and Text by Pete Nawrocky Copyright 2003 Lamartek Inc. D/B/A Dive Rite 0 Warning This manual is only to be used as a guide
Process Equipment Catalog Pumping Solutions for Process Industries
Process Equipment Catalog Pumping Solutions for Process Industries Proven Quality. Leading Technology. Table of Contents Process Equipment Buyer s Guide Contents Air-Operated Double Diaphragm Pumps Model
Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47)
47 Brakes - Hydraulic Components (Page GR-47) FS III front brake calipers, servicing Front brake caliper piston, removing and installing FN 3 front brake calipers, servicing Front caliper piston, removing
Repair of Hyd-ro-ac Actuators
Repair of Hyd-ro-ac Actuators OVERHAUL INSTRUCTIONS SS-.2A-1V SS-.5A-1V SS-.5A-2V Read the entire contents of these instructions before installing the actuator and before making any connections to the
Rexroth Hydraulic Pump A10VO Series User Manual
Rexroth Hydraulic Pump A10VO Series User Manual Rexroth Hydraulic pump A10VO Series User Manual Revised 5/1/2009 Page 1 of 12 Functional Purpose This pump is preferred over a fixed displacement (gear)
OP300S / OP350 2:1 RATIO TRANSFER PUMP
OP300S / OP350 2:1 RATIO TRANSFER PUMP OPERATING MANUAL WITH PARTS IDENTIFICATION Copyright 2013 International Pump Manufacturing, Inc. This manual contains IMPORTANT WARNINGS and INSTRUCTIONS. Read and
INSTALLATION & OPERATING INSTRUCTIONS
INSTALLATION & OPERATING INSTRUCTIONS WARNING RISK OF ELECTRIC SHOCK. CONNECT ONLY TO A CIRCUIT PROTECTED BY A GROUND-FAULT CIRCUIT-INTERRUPTER. THE UNIT SHOULD BE INSTALLED BY A QUALIFIED SERVICE REPRESENTATIVE.
Voltmaster Trash Pumps Model TSP2, TSP3 and TSP4
Model TSP2, TSP3 and TSP4 Owner s Manual July 2010 Table of Contents 1 Introduction...................................................... 1 1.1 Read before using..............................................
3", 4", 6" & 8" Model H Series Alarm Check Valve Installation and Maintenance Guide
", ", " & " Model H Series Alarm Check Valve Installation and Maintenance Guide 077 AIRPARK DRIVE STANDISH, MICHIGAN PHONE 99-- 00-2-0 FAX 99--92 www.globesprinkler.com OCTOBER 2 C- BULLETIN A.C.V.I.M.,
INSTRUCTIONS AND PARTS LIST FOR MODEL 70H & 75H HAND-OPERATED HYDRAULIC PRESS
INSTRUCTIONS AND PARTS LIST FOR MODEL 70H & 75H HAND-OPERATED HYDRAULIC PRESS SETTING UP THE PRESS FOR OPERATION For shipping convenience, the gauge, pump handle, hoist crank, screw nose and base angles
WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!
WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU! Atlanta (Monroe) GA 770-267-3787 [email protected] www.gpmhydraulic.com What You Don t Know About Hydraulic Accumulators Can Kill You TABLE OF CONTENTS
Your safety and the safety of others are very important.
NATURAL GAS TO PROPANE CONVERSION KIT 090 INSTALLATION INSTRUCTIONS FOR ALTITUDES 0 -,00 FT. ONLY PROPANE CONVERSION KIT SAFETY... INSTALLATION REQUIREMENTS... Tools and Parts... LP Gas Requirements...
Hydraulic Air Riveter. Operation Manual RC197 RC198. Recommend for mass production line industrial area. Page 1
Hydraulic Air Riveter Recommend for mass production line industrial area Operation Manual RC197 RC198 Page 1 CONTENTS 1 Important Safety Rules 2 Tool Specification 2.1 Nomenclature 2.2 Technical Data 3
Volkswagen Jetta, Golf, GTI 1999, 2000 2.8 Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)
17 Engine-Lubrication (Page GR-17) Lubrication system components, removing and installing Oil filter housing, disassembling and assembling Oil pan, removing and installing Oil pressure and oil pressure
Machine needle shut-off nozzle type HP
Machine needle shut-off nozzle type HP pneumatically or hydraulically controlled Index of contents Chapter Page Safety instructions... 2 Installation instructions... 3 - Installation steps... 3 Initial
These features have made Lo Torc valves the choice of high pressure plug value users, worldwide:
LO TORC Plug Valve The high value, dependable performance, and low maintenance requirements of Halliburton Lo Torc valves can help reduce overall operating costs and help cut downtime. These features have
Air Eliminators and Combination Air Eliminators Strainers
Description Air Eliminators and Combination Air Eliminator Strainers are designed to provide separation, elimination and prevention of air in piping systems for a variety of installations and conditions.
This instruction is valid for all ACD pump models shown on page 2
Screw pumps ACD Maintenance and Service Instruction This instruction is valid for all ACD pump models shown on page 2 Contents Page List of components 2 Exploded view/ordering code 3 Service intervals
Instructions Parts List
Instructions Parts List ALUMINUM AND STAINLESS STEEL Husky 590 Air-Operated Diaphragm Pumps 0844ZAG.5 inch AODD pump for fluid transfer applications. For professional use only. See Models on page for a
Powers Controls TH 192 S Single Temperature Room Thermostat
Technical Instructions Document No. 155-065P25 TH 192-1 Powers Controls TH 192 S Single Temperature Room Thermostat 50 60 70 80 TH0355R1 70 80 POWERS Description The TH 192 S thermostats are proportional
Fluid Regulator. Instructions Parts List 306563L LOW PRESSURE
Instructions Parts List LOW PRESSURE Fluid Regulator 306563L For accurate, positive control of fluid pressure to one spray gun, dispensing valve, or atomizing head. For professional use only. 250 psi (18
Tri-Homo Style Operation and Maintenance Instructions
Tri-Homo Style Operation and Maintenance Instructions One Research Drive Stratford, CT 06615 (203) 375-0063 www.sonicmixing.com 1 Installation and Start-up Do not perform following adjustments without
2006 HEADSHOK Service Video #1
LEFTY SPEED DLR DAMPING CARTRIDGE This document explains how to properly remove, disassemble, inspect, reassemble and reinstall the Lefty Speed DLR2 damping cartridge. It is a document to be used in conjunction
Air-Oxygen Blender. Service Manual. Model No. PM5200 Series PM5300 Series (shown)
Service Manual Model No. PM5200 Series PM5300 Series (shown) SAVE THESE INSTRUCTIONS 300 Held Drive Tel: (+001) 610-262-6090 Northampton, PA 18067 USA Fax: (+001) 610-262-6080 www.precisionmedical.com
2" & 3" Poly Wet Seal Pump Instruction Manual
Always place the pump as close to the liquid to be pumped as possible. Keep the suction line short and with few bends. Keep the pump and engine on a level foundation. A poor foundation and a heavy suction
ROUGHNECK II Pumpless Drain
SERVICE BULLETIN SB4027 Rev. I 1/11 For Used Oil Only ROUGHNECK II Pumpless Drain Model #4110-022 FOR USED OIL ONLY (Black) For Antifreeze Only Model #4110-023 FOR USED ANTIFREEZE ONLY (Green) Patent #
INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX
Fan Coil Replacement Coil Kit EBX & EBXX These instructions must be read and understood completely before attempting installation. These instructions covers the installation of replacement coil kit into
2007 Hummer H3. 2007 BRAKES Disc Brakes - H3. Fastener Tightening Specifications Specification Application
2007 BRAKES Disc Brakes - H3 SPECIFICATIONS FASTENER TIGHTENING SPECIFICATIONS Fastener Tightening Specifications Specification Application Metric English Backing Plate Bolts 135 N.m 100 lb ft Brake Hose
Drive shaft, servicing
Volkswagen Passat B6 - Drive shaft, servicing Стр. 1 из 41 40-7 Drive shaft, servicing Drive shafts, overview I - Assembly overview: Drive axle with CV joint VL100 40-7, Drive axle with CV joint VL100,
SunMaxx Solar Filling Station Operating Instructions
SunMaxx Solar Filling Operating Instructions Content 1. Declaration of conformity... 2 2. Introduction... 2 3. Transportation and unpacking... 4 4. Mounting and commissioning... 5 5. End of operation...
Trillium 40 Axis Spring Tensioner Wire Replacement Instructions
Trillium 40 Axis Spring Tensioner Wire Replacement Instructions 1 Overview The objective is to replace the broken axis spring tensioner wire. This requires the following tasks: 1. Remove the seismometer
PBX Series Quick Fit Connector Bimetallic Steam Traps
6262100/6 IM-P626-01 ST Issue 6 PBX Series Quick Fit Connector Bimetallic Steam Traps Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Commissioning
CHROME FRONT BRAKE MASTER CYLINDER KIT
-J075 REV. 009-0-0 CHROME FRONT BRAKE MASTER CYLINDER KIT GENERAL Kit Number 5-99D, 5-99D Models These Chrome Master Cylinder Kits are designed to replace the original equipment front brake master cylinder
WILROY. Operation. Optional Diaphragm Rupture Detection HYDRAULICALLY ACTUATED DIAPHRAGM PUMP
WILROY ATEX Approved HYDRAULICALLY ACTUATED DIAPHRAGM PUMP Williams and Milton Roy have combined technologies to design a pump blending the proven mroy hydraulic by-pass diaphragm design with the Williams
Char-Lynn Hydraulic Motors. Repair Information. W Series Geroler Motors 002, 003. April, 1999
Char-Lynn Hydraulic Motors April, 1999 Repair Information W Series Geroler Motors 002, 003 W Series Geroler Motors Tools Required 5/16 inch Hex Key Bullet for Shaft Installation - Eaton Tool No. 600633
TUTORIAL. REbUILdING. front CALIpER O-RING CONVERSION CORVETTE 1965-82. Part #: HT-1
Part #: HT-1 1965-82 CORVETTE O-RING CONVERSION front CALIpER REbUILdING TUTORIAL Choosing a Brake Caliper Rebuild Kit Standard Lip Seals vs. O-Ring Seals Lip seal design seals are used on 1965-1982 Corvette
NITROUS TRANSFER PUMP INSTRUCTIONS
NITROUS TRANSFER PUMP INSTRUCTIONS SAFETY TIPS Never directly inhale nitrous oxide. When inhaled in large quantities, nitrous oxide can cause respiratory ailments or in extreme cases, death by suffocation.
TECHNICAL DATA. Dry 122a. November 12, 2013
Dry 122a 1. PRODUCT DESCRIPTION The Viking is a quick-opening device. When installed with the required external Anti-flood Device, the assembly is designed to increase the operating speed of Viking Model
GATE VALVES ASAHI AV VALVES. Type P (Standard: Plug) Type S (Soft Seal) Contents. (1) Be sure to read the following warranty clauses of our product 1
Serial No. H-V011-E-11 GATE VALVES Type P (Standard: Plug) Type S (Soft Seal) Contents (1) Be sure to read the following warranty clauses of our product 1 User s Manual (2) General operating instructions
Rental Services Temporary Cooling - Flexible Water Hose
Engineering Bulletin Rental Services Temporary Cooling - Flexible Water Hose September 2006 CHS-PRB007-EN Warnings and Cautions Warnings and Cautions. Notice that warnings and cautions appear at appropriate
Flygt Ball Check Valves
4/13 Supersedes: 6/96 The basic purpose of a check valve is to permit flow in one direction, prevent flow in the opposite direction and perform this function automatically and with minimum maintenance.
CG-1171-20 PTFE Diaphragm Liquid Transfer Pump
3800 N. Mill Road Vineland, NJ 08360 Phone: 800.843.1794 Fax: 800.922.4361 CG-1171-20 PTFE Diaphragm Liquid Transfer Pump This is the safety alert symbol. It is used to alert you to potential personal
Vertical selfpriming Side-Channel Pumps Type WPV
Vertical selfpriming Side-Channel Pumps Type WPV FIELD OF APPLICATION The side-channel pumps are selfpriming and operate more economically (better efficiency) than normal centrifugal pumps when handling
2006 JUDY SERVICE GUIDE
2006 JUDY SERVICE GUIDE For exploded diagram and part number information, refer to the Spare Parts Catalog available on our website at www.rockshox.com. Information contained in this publication is subject
Installation Manual. Solar Pool Heating System. Read the complete manual before beginning the installation
Solar Pool Heating System Installation Manual Read the complete manual before beginning the installation 1. Sizing the System Visit www.techno-solis.com to size the system using the sizing calculator.
TUTORIAL. REbUILdING. REAR CALIpER O-RING CONVERSION CORVETTE 1965-82. Part #: HT-2
Part #: HT-2 1965-82 CORVETTE O-RING CONVERSION REAR CALIpER REbUILdING TUTORIAL Choosing a Brake Caliper Rebuild Kit Standard Lip Seals vs. O-Ring Seals Lip seal design seals are used on 1965-1982 Corvette
5800 Temperature Sensor Cable Assembly
5800 Temperature Sensor Cable Assembly Removal and Replacement Instruction Sheet #60-4702-070 Revision D, January 14, 2013 Overview The 5800 has two refrigeration temperature sensors, one attached to the
ABV20 Air Actuated Boiler Blowdown Valve Installation and Maintenance Instructions
4057250/8 IM-P405-16 AB Issue 8 ABV20 Air Actuated Boiler Blowdown Valve Installation and Maintenance Instructions 1 General safety information 2 General product information 3 Installation 4 Operation
APCO SLOW CLOSING AIR/VACUUM VALVES
BULLETIN 1 JULY 01 APCO SLOW CLOSING AIR/VACUUM VALVES Series 1900 APCO Slow Closing Air/Vacuum s Maximum Air Flow Velocity in Good Pipeline Design The Air/Vacuum operates in the normal fashion allowing
INSTRUCTIONS. FLHR/C/S (Road King) FRONT END LOWERING KIT 1WARNING -J03242 REV. 10-19-04. General. Removal (Left and Right Forks) Kit Number 54614-05
INSTRUCTIONS -J04 REV. 0-9-04 General FLHR/C/S (Road King) FRONT END LOWERING KIT This kit is designed for installation on 00 and later FLHR/C/S Model Motorcycles. Road King models use the conventional
MODEL T200-F18 MODEL T125-F18 Finish Nailers
P MODEL T200-F18 MODEL T125-F18 Finish Nailers IMPORTANT! DO NOT DESTROY It is the customer s responsibility to have all operators and service personnel read and understand this manual. OPERATING MANUAL
Series 30000 Hose Reels
Operating Instructions and Parts List for Series 30000 Hose Reels - MANUAL DRIVEN - - POWER DRIVEN - SAFETY PRECAUTIONS Personal injury and/or equipment damage may result if proper safety precautions are
3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE
4 3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE A. Changing the Control Board B. Replacing a Heating Element C. Thermistor Replacement D. High Limit Switch Replacement E. Level Detector Replacement
Service Manual Rol-Lift
R 2000 Service Manual Rol-Lift Series: T and E Developed by Generic Parts Service This manual is intended for basic service and maintenance of the Rol-Lift pallet jack. The pallet jacks you are servicing
Universal Adjustable Fuel Pressure Regulator
Universal Adjustable Fuel Pressure Regulator Installation Instructions for: Part Numbers 25-302 U.S. Patent # 6,298,828! Due WARNING: to the fact that this installation deals with your fuel system this
Installation, Maintenance, & Repair Series 4000B/LF4000B
Installation, Maintenance, & Repair Series 4000B/LF4000B Reduced Pressure Zone Assemblies Sizes: 1 2" 2" (15 50mm) RP/IS-A-4000B 4000B/LF4000B Size: 3 /4"! WARNING Testing Read this Manual BEFORE using
SureSite Magnetic Liquid Level Indicator
SureSite Magnetic Liquid Level Indicator Instruction Bulletin No. 177664-1 (Rev. E) Section 1: Weldments Thank you for purchasing the GEMS SureSite Magnetic Level Indicator. Please read this document prior
Installation, Operating and Maintenance Instructions for AEON Metal Seated Gate Valve (MSGV) Water
1 Foreword 1.1 Thank you for choosing one of the range of AEON's BS standard valves. For safety purposes, the user shall read this instruction to fully understand the operation of the product. 2 AEON Design
Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat
Document No. 155-068P25 TH 193-4 Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat 50 60 70 80 70 TH0356R1 60 80 POWERS Description The TH 193 HC thermostats are proportional dual
Tech. Services: (800) 477-8326 Fax: (800) 765-8326 Order Entry: (800) 541-1418 Fax: (800) 288-7031 Internet Address: http://www.powerteam.
ORIGINAL INSTRUCTIONS Form No.102842 5 SPX Hydraulic Technologies 5885 11th Street Rockford, IL 61109-3699 USA Tech. Services: (800) 477-8326 Fax: (800) 765-8326 Order Entry: (800) 541-1418 Fax: (800)