FLIGHT SECOND STAGE REGULATOR
|
|
|
- Lenard Casey
- 9 years ago
- Views:
Transcription
1 TECHNICAL SUPPORT FLIGHT SECOND STAGE REGULATOR MAINTENANCE MANUAL FOR AUTHORISED TECHNICIANS Document No. AP4498 Issue 9 28/11/2011 APEKS MARINE EQUIPMENT LTD, NEPTUNE WAY, BLACKBURN, LANCASHIRE. BB1 2BT Tel: 0044 (0) Fax: 0044 (0) [email protected] Web:
2 Amendments record: Amendments and approval of this document can only be carried out by the relevant people listed on the Approved list of signatures, which is listed in the Apeks Quality Manual. To instigate a change, a Task / Change request form, (Form No. DESI/10002 ), must be completed and passed to the relevant person(s) for approval which are listed on the Approved List of Signatures. When approval has been granted and recorded this table can then be completed and the document up issued. Change No. Change Request No. Description & Comments: Change Date New Issue No. Changed By: Approved By: Add details of new O ring pick 16/02/11 06 RH ACD 1158 NA Added note for removing purge clamp ring 16/09/11 07 AB ACD 1175 NA Added Twilight Pt no to Drawing 28/10/11 08 AB ACD 1178 NA Added details of new new silicone seating 28/11/11 09 AB ACD 2
3 Contents Copyright notice...3 Introduction...3 Warnings, Cautions & Notes...3 Scheduled Service...3 General Guidelines...3 General Conventions...4 Disassembly Procedures...4 Inspection PROCEDURES...7 REASSEMBLY PROCEDURES...8 TESTING Table 1 - troublshooting guide Table 2 - Recommended tool list Table 3 - REcommended lubricants and cleaners cleaning and lubrication procedure TABLE 4 -torque specifications Table 5 - test bench specifications Flight exploded parts drawing
4 Copyright notice This manual is copyrighted, all rights reserved. It may not, in whole or in part, be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine readable form without prior consent in writing from Apeks Marine Equipment Ltd. It may not be distributed through the internet or computer bulletin board systems without prior consent from Apeks Marine Equipment Ltd Apeks Marine Equipment Ltd. Introduction Flight Seond Stage Maintenance Manual (AP4498 Issue 9 ) This manual provides factory prescribed procedures for the correct maintenance and repair of the Apeks Flight second stage regulators. It is not intended to be used as an instructional manual for untrained personnel. The procedures outlined within this manual are to be performed only by personnel who have received factory authorised training through an Apeks Service & Repair Seminar. If you do not completely understand all of the procedures outlined in this manual, contact Apeks to speak directly with a Technical Advisor before proceeding any further. Warnings, Cautions & Notes Pay special attention to information provided in warnings, cautions, and notes that are accompanied by one of these symbols: WARNINGS indicate a procedure or situation that may result in serious injury or death if instructions are not followed correctly. CAUTIONS indicate any situation or technique that will result in potential damage to the product, or render the product unsafe if instructions are not followed correctly. NOTES are used to emphasise important points, tips, and reminders. Scheduled Service It is recommended that the Apeks Flight second stage regulators should be examined annually regardless of usage. However, If at all unsure about the correct functioning of the Apeks second stage, then it must be officially inspected immediately. All service and inspection details need to be documented in the Regulator Service Record in the back of the Owner s Manual to keep the Limited Lifetime Warranty in effect. An Official Inspection consists of: 1. A pressurised immersion test of the entire unit to check for air leakage. 2. Checking for stable medium pressure that is within the acceptable range. 3. Checking for opening effort that is within the acceptable range. 4. Checking for smooth operation of the venturi switch. 5. A visual inspection of any filters for debris or discolouration. 6. Pulling back hose protectors and checking that the hoses are secure in the hose crimps. 7. A visual inspection of the exhaust valve(s) to see that they are in good condition and that it is seating against a clean and undamaged surface. 8. A visual inspection of the mouthpiece looking for tears or holes and checking the general condition. 9. A visual inspection of the Slide Locking Ring. Check that the Ring is in good condition with no cracks or splits. Ensure that the two teeth are in good condition and that the Hose Nut cannot be unscrewed without squeezing the Ring. If a regulator fails steps 1,2,3,4 or 9 the entire regulator should be serviced. If a regulator fails 5,7 or 8 it will be up to the technician s discretion whether or not a full service is required. Failure of step 6 requires replacement of the Hose. General Guidelines 1. In order to correctly perform the procedures outlined in this manual, it is important to follow each step exactly in the order given. Read over the entire manual to become familiar with all procedures and to learn which specialty tools and replacement parts will be required before commencing disassembly. Keep the manual open beside you for reference while performing each procedure. Do not rely on memory. 2. All service and repair should be carried out in a work area specifically set up and equipped for the task. Adequate lighting, cleanliness, and easy access to all required tools are essential for an efficient repair facility. 3. During disassembly, reusable components should be segregated and not allowed to intermix with nonreusable parts or parts from other units. Delicate parts, including inlet fittings and valve seats which contain critical sealing surfaces, must be protected and isolated from other parts to prevent damage during the cleaning procedure. 4. Use only genuine Apeks parts provided in the Flight 2nd stage service kit (AP0254). DO NOT attempt to substitute an Apeks part with another manufacturer s, regardless of any similarity in shape or size. 5. Do not attempt to reuse mandatory replacement parts under any circumstances, regardless of the amount of use the product has received since it was manufactured or last serviced. 6. When reassembling, it is important to follow every torque specification prescribed in this manual, using a calibrated torque wrench. Most parts are made of either marine brass or plastic, and can be permanently damaged by undue stress. 4
5 General Conventions Unless otherwise instructed, the following terminology and techniques are assumed: 1. When instructed to remove, unscrew, or loosen a threaded part, turn the part anti-clockwise. 2. When instructed to install, screw in, or tighten a threaded part, turn the part clockwise. 3. When instructed to remove an O Ring, use the pinch method (see figure below) if possible, or use a brass, aluminium or plastic O Ring removal tool. Avoid using hardened steel picks, as they may damage O Ring sealing surfaces. All O Rings that are removed are discarded and replaced with brand new O Rings. NOTE: When servicing flight regulators it is good practice to follow the sequence of operations stated below: 1) Strip down both the 1st stage and 2nd stage 2) Clean and inspect all regulator parts as laid out in the procedures in both manuals. 3) Reassemble the 2nd stage (but do not adjust or set) 4) Reassemble and set the 1st stage (following procedures as laid out in the 1st stage manual) 5) Set the 2nd stage (following procedures as laid out in the manual). The reason for leaving the 2nd stage before setting is to allow the seating area to seat and bed in better, therefore optimising performance and adjustment. Pinch Method Press upwards on sides of O Ring to create a protrusion. Grab O Ring or insert O Ring tool at protrusion. Removal of hose 1. Pull back the Hose Protector, pinch the Locking Slide Ring (19) on the opposing grips, and unscrew the hose from the second stage. Remove the O ring from inside the Hose Swivel. Exercise caution not to scratch the O ring groove. Remove the O ring from the Hose Nut end of the Hose. 4. The following acronyms are used throughout the manual: MP is Medium Pressure; HP is High Pressure; PN is Part Number. 5. Numbers in parentheses reference the key numbers on the exploded parts schematics. For example, in the statement,...remove O ring (11) from..., the number 11 is the key number to the Inlet Fitting O Ring. Disassembly Procedures NOTE: Before performing any disassembly, refer to the exploded parts drawing, which references all mandatory replacement parts. These parts should be replaced with new, and must not be reused under any circumstances - regardless of the age of the regulator or how much use it has received since it was last serviced. CAUTION: Use only a plastic, brass or aluminium O Ring removal tool (PN AT79) when removing O Rings to prevent damage to the sealing surface. Even a small scratch across an O Ring sealing surface could result in leakage. Once an O Ring sealing surface has been damaged, the part must be replaced with new. DO NOT use a dental pick, or any other steel instrument. CAUTION: DO NOT use any tools to remove the Hose. The connection has been designed to be operated by hand only. 2. Pull back the Hose Protector and inspect the Hose Crimps. If either Crimp is damaged or the Hose is pulling out of the crimp then the Hose must be replaced. Removal of Exhaust Tee 3. Place one finger into each side of the Exhaust Tee (8) and squeeze them together. Pull the Exhaust Tee away from the Case (6). 5
6 Removal of Mouthpiece 4. Unfasten the Mouthpiece Clip (12) and pull the Mouthpiece off the Case(6) CAUTION: Take care not to damage or distort the Lever (15) when removing the Venturi Lever (10). DO NOT depress the tab of the Venturi Lever too far, as this will result in permanent deformation. 8. Remove the O ring from the Venturi Lever (10) taking care not to scratch the O ring Groove. 5. To remove the Purge Clamp Ring (1) squeeze at the positions shown on the photo below and turn anti-clockwise. Separate the Purge Clamp Ring (1) from the Front Cover Assy (2) and the Case (6). NOTE: A latex grip glove i.e an Arco Gripz or an equivalent product will aid the removal of the purge ring. 9. Remove the Sliding Locking Ring (19)by pulling in an axial direction away from the case and gently rocking side to side to loosen the component. 6. Locate the three kidney shaped pegs of the AT71 Locking Ring Tool into the slots of the Inner Locking Ring (3). Unscrew the Inner Locking Ring (3). Remove the Friction Ring (4) and the Diaphragm (5) from inside of the Case (6). 10. To remove the inlet fitting (18) use the venturi combination tool (AT77), align the grooves on the tool with those on the fitting and turn in an anti clockwise direction to unscrew. once satisfied that the thread has disengaged, the inlet fitting may require a little pull as the O ring will be holding it in the bore of the case. Once the inlet fitting has been removed from the case, carefully remove the O ring, taking care not to scratch the O ring groove. 7. To remove the Venturi Lever (10) from the Case (6), position the lever vertically as shown below. Locate the venturi lever removal tool (AT77) on the venturi lever side first, then press down on the opposite side to push out the venturi lever. 11. To remove the spindle body (14) from the case (6) use the opposite end of the cracking effort adjuster tool to push it out. WARNING: Do not use any other method or tool to unscrew or tighten the inlet fitting 6
7 12. Carefully remove the Valve Spindle (14) from inside the Case (6). 15. Using an O ring removal tool press the Spindle Adjuster Sleeve (21) out of the Spindle Body (14). 13. Using a 5mm Allen Key unscrew the Valve Seat (17) from the Inlet Fitting (18) and remove the O ring from the Seat. NOTE: There is no need to remove the Micro Adjuster Screw (20) from the Spindle Adjuster Sleeve (21). 16. Fold back the edges of the Exhaust Valve (7) and inspect underneath. The seating surface should be clean and free of damage. Inspect the Exhaust Valve. It should be supple and have well defined edges. If it looks good, there is no need to remove it and it may be reused. If there is any sign of deterioration, it should be replaced. CAUTION: Take care when handling the Valve Seat (17). The sealing face of the Seat must be protected from damage or the regulator will leak. 14. To remove the Lever (15) from the Spindle Body (14) screw the AT48 1st and 2nd stage tool into the spindle to compress the spring. Carefully pull one of the legs out of the Valve Body and then ease the second leg out. Separate the Shuttle Valve assembly (22-26) as shown below, making sure that the O ring (24) is removed from the Shuttle Valve (25). NOTE: If the Exhaust Valve (7) is to be removed, pinch the edge of the Valve and pull the tail through the hole in the Case (6). This Ends Disassembly Before starting reassembly, perform parts cleaning and lubrication according to the procedures outlined in Cleaning & Lubrication on page 16. 7
8 INSPECTION PROCEDURES NOTE: Before performing any reassembly procedures, several parts must be inspected. The following section details the parts and areas that must be checked. The following parts should be checked for cracks, deep scratches, excessive wear and tear and distortion. Sealing faces, grooves and bores should be checked for scratches. Inlet Fitting (18) 1. Inspect the outside of the Inlet Fitting (18), ensure that there are no cracks or scratches. Check that there are no cracks or splits in both of the bores and that the O ring groove is in good condition. Check the condition of both threads, pay particular attention to the fine thread. If in any doubt replace the part. Front Cover Assembly (2) 1. Inspect the back face of the Front Cover Assembly (2), ensure that the Metal Legs of the Decal are pressed firmly down. Check that the Rubber Purge Spring is firmly located around the entire perimeter of the Front Cover. Hose Nut 1. Check the teeth of the Hose Nut, ensure that there are no cracks or scratches and that they are not excessively worn. Check that the threads are in good condition and ensure that the Nut spins freely. Venturi Lever (10) 1. Check that the tab of the Venturi Lever (10) has not been over stressed and that it is level with the rest of the lever. Spindle (14) 1. Check that the Spindle Body (14) is free from scratches, cracks and distortion. Look for excessive wear around the Lever (15) holes. Check that the thread is in good condition. Slide Locking Ring (19) 1. Inspect the teeth of the Slide Locking Ring (19), ensure that they are relatively sharp and not excessively worn. Check that there are no cracks or splits by gently trying to pull apart the flexible ring of the part as shown below. REASSEMBLY PROCEDURES Assembling of the Spindle Body 1. Carefully insert the Spindle Adjuster Sleeve (21) into the Spindle Body (14). Ensure that two legs of the Spindle Adjuster Sleeve correctly line up with the slots in the Body. Check the Spindle Adjuster Sleeve is firmly pressed into the end of the Body. 8
9 2. Install a new lubricated O ring (24) onto the Spring Carrier (22). Check the bore of the Shuttle Valve (25) to ensure that the old O ring has been removed. Insert the Spring Carrier (22) into one end of the Spring (23) and the Shuttle Valve (25) into the other, carefully guiding the end of the Carrier into the bore of the Shuttle valve. 3. Insert the Spring Carrier end of the assembly into the Spindle Body (14). Screw in the AT48 tool to fully compress the Spring until it passes the triangular shaped hole in the Body. (Please note: it may be necessary to do this with the grey silicone seat (26) in place. Insert the feet of the Lever (15) into the gap, this retains the Shuttle Valve inside the Body. NOTE: Please take note of what type of spring carrier is inside the regulator (Dot or No Dot see pictures below) as this will affect the setting procedure. (see 2nd stage opening effort procedure) Dot No Dot CAUTION: Take care not to damage the Silicone seating (26). CAUTION: Ensure that the Lever is not twisted and that legs are parallel. Lever should appear as that shown on the left, not as shown on the right. If necessary, gently squeeze legs together to straighten. NOTE: When fitting the new seat (26) only use the grey silicone seating (pt no129638). Older Flight models may have the standard black rubber seat fitted (pt no AP2034) please discard as these are no longer used on the Flight 2nd stage. Grey Silicone Seat Black Rubber Seat NOTE: Ensure that the Lever has a full range of movement and does not catch on the Valve Spindle Body. Ensure that the spring can be seen through the Valve Spindle Hole. 9
10 4. Carefully insert a new Silicone Seating (26) into the end of the Shuttle Valve (25).(If not already) CAUTION: Use only the end of your finger to insert the new Silicone seating (26), NOT your finger nail. DO NOT mark the face of the Silicone seating, this will cause the 2nd stage to leak when fully assembled. 7. Install a new Lubricated O ring (11) onto the Inlet Fitting (18). Fitting Spindle Assembly into Case CAUTION: DO NOT use the lever to push the Spindle into the case as this will bend the lever. 8. Screw the Inlet Fitting (18) into the end of the Spindle Body (14) and hand tighten until the grooves line up. Use the venturi combination tool (AT77) 5. Insert the Spindle Body assembly into the Case. Using the opposite end of the cracking effort adjuster tool (AT76) Push the Body firmly into the Case ensuring that there is no gap between the two parts. Ensure that the Lever has a full range of movement and does not catch on the Valve Spindle Body. warning: Only use the venturi combination tool (AT77) to remover or tighten the inlet fitting. Over tightening of this part will result in damage. 9. Align the location splines of the Locking Slide Ring (19) to the grooves on the Inlet Fitting (18) and Case (6). Using the palm of your hand carefully push the Locking Slide Ring (19) fully upto the Case (6) until it clicks. 6. Install a new Lubricated O ring (16) onto the Valve Seat (17). Carefully push the Valve Seat (17) into the smaller diameter bore of the Inlet Fitting (18). Using a 5mm Allen key turn the valve seat counter clockwise until it bottoms out. 10
11 10. While holding the Case (6) at eye level, use a 5mm Allen key to screw the Valve Seat (17) clockwise until the Lever (15) drops just below the rim of the Case. Check by gently flicking the lever, it should bounce and have free movement. The lever should return to its set position, if it sticks then the lever is not square, fitted incorrectly or it is bent. CAUTION: Ensure that the Lever (15) moves freely and sits vertically within the case (6). 11. Refit the Diaphragm (5) into the front of the Case (6). Using your finger carefully work the edges of the Diaphragm into place so it sits evenly in the Case. Insert the Flight Friction Ring (4) into the case. Use the same technique to ensure it sits evenly onto the Diaphragm. FLIGHT Second Stage Regulator Maintenance Manual Final Testing Warning: Compressed air can be highly explosive and is dangerous if misused. Ensure the cylinder valve is opened slowly. Use eye and ear personal protective equipment when performing any tests involving compressed air. Setting the Lever Height NOTE: When fitting the grey silicone seat the lever height can be set higher and more sensitive and will improve the performance of the second stage. This can be done with the new setting tool AT75 marked with B. The older tool should be discarded. CAUTION: The lever setting tool AT75 should only be used during a full rebuild or when the silicone seating has been replaced. It should not be used for re-adjusting the lever height of returning customer second stages. 1. Refit the hose onto the second stage until it stops. DO NOT use any tools as this will damage the connection. Audible clicks should be heard as the hose is screwed into place. Check that the hose cannot be unscrewed without squeezing the Sliding Locking Ring. Warning: Tools are not required for attaching or removing the hose, hand tight is sufficient. 2. Connect the first stage regulator to a calibrated test bench and pressurise the system to 200 (±10) bar. 3. Place the NO GAS FLOW side of the Flight Setting Tool (PN AT75) onto the plastic pad of the Diaphragm (5). Depress the Diaphragm by pushing the tool in until it stops against the Case. If no gas flows from the second stage proceed to step 5. If gas flows from the valve follow step 4. CAUTION: Ensure that the Diaphragm (5) and Flight Friction Ring (4) are seated correctly and are not creased. 12. Refit the locking ring ensuring the 3 small grooves are facing up. (see pic below). Using the AT71 Tool slowly screw the Inner Locking Ring (3) into the Case. Hand tighten only. Once the diaphragm is secure, gently grip the diaphragm pad between the thumb and forefinger, and gently pull from side to side to check the diaphragm is secure. 4. Disconnect the second stage from the hose as shown in step 1 of the disassembly procedure, (excluding O ring removal). Using the Flight Inline Adjuster Tool (PN AT72/F) or 5mm Allen key as appropriate, turn the Valve Seat (17) clockwise by approximately 1/16 of a turn (see step 12 of the disassembly procedure for Ref.). This lowers the lever inside. Repeat step Place the GAS FLOW side of the Flight Setting Tool (PN AT75) onto the plastic pad of the Diaphragm (5) as positioned before. Depress the Diaphragm by pushing the tool in until it stops against the Case. If gas flows from the second stage the lever height inside is correct. However, if no gas flows from the valve this means that the lever is now set too low. Proceed to step 6. 11
12 6. Disconnect the second stage from the hose as shown in step 1 of the disassembly procedure. Using the Flight Inline Adjuster Tool (PN AT72/F) or 5mm Allen key as appropriate, turn the Valve Seat (17) anti- clockwise by approximately 1/16 of a turn (see step 6 of reassembly procedures for Ref.). Repeat step 2. NOTE: It is important to ensure that the rim of the AT71 Flight Setting Tool is concentric with the Case (6). If the Tool is misaligned it will not measure the diaphragm travel correctly and therefore, sensitivity. 7. Place the Front Cover Assembly (2) into the front of the Case (6) as shown below. Fit the Purge Clamp Ring (1) over the top of the Front Cover Assembly (2). Rotate the Purge Clamp Ring (1) clockwise until it firmly clicks into place. Second Stage Opening Effort Test NOTE: Regulators with serial numbers from to will need to be de-pressurised when the second stage opening effort is adjusted, this is to ensure an accurate reading and optimum performance as previously described. These 2nd stages will have a dotted spring carrier fitted. NOTE:When newly built all regulators will also benefit from being left for a minimum of ten minutes before being pressurised and the opening effort set. 1. Insert the Flight Micro Adjuster Tool (AT76) into the open side of the Case (6), making sure that the hexagonal bit engages into the Micro Adjuster Screw (20). Connect the first stage regulator to a calibrated test bench and pressurise the system to 200 (±10) bar. Slowly open the flowmeter control knob (start vacuum) while watching both the magnahelic gauge and the intermediate pressure gauge. 2. When the intermediate pressure begins to drop, indicating the second-stage valve is open, the magnahelic gauge should indicate an opening effort of +1.4 in.h 2 O (3.5mbar) to +1.6 in.h 2 O (4 mbar). If the reading is outside of these specifications, adjust the Micro Adjuster Screw (20), turning anti-clockwise to lower the opening effort or clockwise to increase the opening effort. If this fails to give the correct reading refer to Table 1 - Troubleshooting for corrective actions. External Leak Test 1. After disconnecting the regulator from the flow bench, connect it to a gas cylinder filled to approximately 200 bar. Open the cylinder valve to repressurise the regulator, and submerge the entire system in a test tank of clean water. 2. Observe any bubbles arising from the submerged regulator over a one minute period. The recommended time is necessary due to slower bubble formation that occurs in smaller leaks. Bubbles indicate a leak, which requires the system to be disassembled at the source to check sealing surfaces, assembly sequence and component positioning in order to correct the problem(s). NOTE: Extremely small leaks may be better detected by applying a soap solution or Snoop to the leak area. Bubble streams will indicate the source of the leak. Before disassembling to correct any leaks, rinse the entire regulator thoroughly with fresh water and blow out all residual moisture with filtered, low-pressure air. Disassemble and remedy the problem, referring to Table 1 - Troubleshooting. 12
13 Final Assembly 1. Install a new lubricated O ring (11) onto the Venturi Lever (10). Align the Venturi Lever in a vertical position with the Case and using the palm of your hand press the lever into place. Ensure that the Venturi Lever rotates freely and feels secure. FLIGHT Second Stage Regulator Maintenance Manual This Ends Reassembly Subjective Breathing Test NOTE: To check that the Diaphragm has sealed correctly, place your thumb over the end of the Inlet Fitting with the hose removed (see paragraph 1 in disassembly to remove and paragraph 1 in final testing to refit). Suck and hold at the mouthpiece port, a vacuum should be held without any leakage. 2. If equipped with a Comfo-bite Mouthpiece, make sure the bridge of the Mouthpiece (13) is facing upward. Stretch the Mouthpiece over the second-stage Mouthpiece outlet port. At the base of the Mouthpiece is a groove for the Mouthpiece Clip (12). Wrap the Clip around the Mouthpiece so that the buckle points toward the Hose. Fasten the Clip, ensuring that the Mouthpiece (13) is securely held in place. 1. Depress the Front Cover Assembly (2) fully to ensure that an adequate volume of air needed to clear the second stage flows through the mouthpiece. Then, inhale slowly but deeply from the mouthpiece. A properly serviced and adjusted regulator should deliver air upon deep inhalation without excessive inhalation effort, freeflow, or fluttering of the second-stage diaphragm. When exhaling, there should be no fluttering or sticking of the exhalation valve. If any of these problems occur, refer to Table 1 - Troubleshooting. 2. With the Venturi Lever set to the + position tap the Front Cover Assembly (2) quickly, this should cause the regulator to freeflow. Stop the freeflow after a couple of seconds by placing a hand over the mouthpiece. 3. Locate the bottom of the Flight Exhaust Tee (8) onto the Case (6). Place a thumb in each exhaust port and push the Tee towards the mouthpiece. Ensure that the Tee fits over the Case and is secure. Taking care not to damage or dislodge the exhaust valve. 13
14 Table 1 - Troubleshooting Guide Symptom Possible Cause Treatment 1. Excessively high first-stage intermediate pressure. 2. Rubber (Black) or Silicone seating (26) damaged or worn. 3. Valve Seat (17) adjusted incorrectly, Lever (15) set too high. 1. Refer to first-stage Troubleshooting Guide. 2. Replace with Silicone Seating. 4. Lever (15) bent. 4. Replace Lever. 3. Reset Seat preliminary settings, and repeat Adjustment Procedures. Leakage or freeflow from Flight Second Stage 5. Valve Seat (17) sealing surface damaged. 5. Replace Valve Seat. 6. Spring (23) damaged. 6. Replace Spring. 7. Shuttle Valve O Ring (24) damaged. 7. Replace O Ring. 8. Shuttle Valve (25) bore damaged. 8. Replace Shuttle Valve. 9. Venturi Lever O Ring (11) damaged. 9. Replace O Ring. Low purge or excessive work of breathing (full cylinder) 1. Low first-stage intermediate pressure. 2. Seat (17) adjusted incorrectly, Lever (15) set too low. 3. Intermediate pressure hose clogged or obstructed. 4. Black rubber seating fitted 5. Lever (15) bent or catching on Valve Spindle (14). 1. Mouthpiece (13) damaged or incorrectly fitted. 1. Refer to first-stage Troubleshooting Guide. 2. Reset Seat preliminary settings, and repeat Adjustment Procedures. 3. Clean or replace Hose. 4. Replace with silicone seating and reset with AT75 setting tool marked with letter B 5. Replace Lever. 1. Replace or re-fit Mouthpiece as appropriate. 2. Diaphragm (5) damaged. 2. Replace Diaphragm. Water entering Flight Second Stage 3. Diaphragm (5) improperly seated in Case (6). 3. Remove Front Cover (4) and Diaphragm Cover (5) properly reassemble Diaphragm (check for distortion). 4. Exhaust Valve (7) damaged. 4. Replace Exhaust Valve. 5. Case (6) damaged. (Check exhaust valve seating surface.) 5. Disassemble and replace Case. 6. Inlet Fitting O Ring (11) damaged. 6. Replace O Ring. 7. Venturi Lever or O Ring (11) damaged. 7. Replace O Ring. 14
15 Table 2 - Recommended Tool List Part No. Description Application AP0430 I.P. test gauge Intermediate pressure testing AT79 O Ring removal pick O Ring removal AT71 Diaphragm Clamp Tool Removal of Composite Diaphragm Clamp/ Locking Ring AT37 5mm Allen key Valve Seat AT75 AT76 Flight Setting Tool Flight Micro Adjuster Tool Setting of Lever height (new issue setting tool will bedenoted with a letter B printed on the face). Setting Micro Adjuster Screw/Removing and Replacing spindle AT77 Venturi Lever Combination Tool Removal of Venturi Lever/Inlet fitting AT72/F Flight inline adjuster tool Lever height setting n/a 230 or 300 Bar diving cylinder AT48 1st and 2nd stage tool Insterting/Removing Lever AP0430 AT79 AT71 AT37 AT48 AT76 AT77 AT72/F AT75 * Tool AT75 will be denoted with a letter B stamped or etched onto the body should you have a tool without the letter B please contact Apeks before performing any adjustments. Notes: 1. Photos not to scale. 2. Actual tools may differ from photos. 15
16 Table 3 - Recommended Lubricants & Cleaners Lubricant / Cleaner Application Source Christo-Lube MCG-111 (Lubricant) All O Ring seals Apeks Marine Equipment Ltd PN AP1495, or Lubrication Technologies 310 Morton Street Jackson, OH 45640, USA (800) CAUTION: Silicone rubber requires no lubrication or preservative treatment. DO NOT apply grease or spray to silicone rubber parts (eg. Diaphragm, Exhaust Valves.) Doing so may cause a chemical breakdown and premature deterioration of the material. Biox (Cleaning agent) White distilled vinegar (100 gr.) (Cleaning agent) Biological immersion fluid for reusable stainless steel and brass parts. Acid bath for reusable stainless steel and brass parts. Solent Divers Ltd Lake Rd, Portsmouth, Hants, PO1 4HH Household grade CAUTION: Do not use muriatic acid for the cleaning of any parts. Even if strongly diluted, muriatic acid can harm chrome plating and may leave a residue that is harmful to O Ring seals and other parts Liquid dishwashing detergent diluted with warm water (Cleaning agent) Degreaser for brass and stainless steel parts; general cleaning solution for plastic and rubber Household grade 16
17 Cleaning & Lubrication Procedure General Cleaning of all Parts 1. Place all components in an ultrasonic cleaning bath containing an appropriate cleaning solution, such as Biox. 2. All plastic and composite components such as the Inlet Fitting and Spindle must be cleaned in soapy water. 3. The components should be cleaned for 6 minutes, depending upon their condition. Longer cleaning times may used if required. 4. Rinse the components in warm fresh water. 5. The components should then be blown dry or left to dry naturally. Lubrication and Dressing All O Rings should be lubricated with Christo-Lube MCG-111. Dress the O Rings with a very light film of grease, and remove any visible excess by running the O Ring between thumb and forefinger. Avoid applying excessive amounts of Christo-Lube grease, as this will attract particulate matter that may cause damage to the O Ring. Enriched Air Nitrox Use - Outside EEC (European Economic Community) Countries Your Apeks regulator has been prepared for use with Enriched Air Nitrox (EAN) where the percentage of oxygen in the EAN does not exceed 40%. This is possible because each regulator is built to a high standard of cleanliness using EAN compatible components and lubricants. In addition, each regulator design has passed stringent adiabatic compression testing to ensure its safety and compatibility with increased percentages of oxygen. If it is your intention to use your new Apeks regulator with Nitrox EAN (O2 not to exceed 40%), it is imperative that you maintain the internal cleanliness of the regulator (see section on Care and Maintenance). If it is your intention to use the regulator interchangeably with breathing air, the breathing air should be oxygen-compatible or hyperfiltered where the condensed hydrocarbons do not exceed 0.1 mg/m3. Your local authorised Apeks dealer can help you determine whether the breathing air that they provide meets this criterion. Standard compressed breathing air meeting the EN standard, often referred to as Grade E in the United States, does not necessarily meet this criterion. Grade E or EN breathing air may contain a certain level of hydrocarbons, including traces of compressor oils that while not considered harmful to breathe, can pose a risk in the presence of elevated oxygen content. Passing hydrocarbons through a valve and regulator creates a cumulative effect where the hydrocarbons build up over time along the internal passageways of the equipment. When these hydrocarbons come into contact with high-pressure oxygen enriched air, they can pose a very real hazard that can lead to combustion. Therefore, if a regulator has had use with Grade E or EN breathing air, it should be returned to an authorised Apeks dealer for overhaul service including oxygen cleaning, prior to being put back into nitrox service. Although second stage components are not exposed to high pressure EAN, Apeks recommends that the same cleaning procedures be followed for the complete regulator. This prevents the possibility of cross contamination and guarantees the cleanliness of the entire regulator. Enriched Air Nitrox Use Inside EEC (European Economic Community ) countries EN and EN13949 In CEE countries, diving with Nitrox/O2 is controlled by Standards EN Respiratory protective devices - Gas cylinder valves - Part 3: Outlet connections for diving gases Nitrox and oxygen - and EN Respiratory equipment - Open circuit self-contained diving apparatus for use with compressed Nitrox and oxygen - requirements, testing, marking. NOTE : Apeks offers a range of regulators designed and manufactured specially for use with oxygen-enriched mixtures, over 21% and up to 100% oxygen. This range has been certified according to the EN and EN standards and meets the requirements of the adiabatic compression tests. They have received CE certification for this type. For further information on this range, contact your Apeks specialist centre. WARNING : These regulators fitted with special connections should be used only with complementary equipment (tank valves, tanks, pressure gauges, etc.) designed and prepared for use with an oxygen-enriched mixture. These items are marked Nitrox/O2. WARNING: If the regulator that you use is fitted with a yoke or DIN connection, it is designed for use only with compressed breathing air (21% oxygen and 79% nitrogen) which meets the EN standard. DO NOT USE this equipment with other mixtures or with gases containing more than 21% oxygen. Disregarding this rule could result in serious injury or death caused by fire or explosion. Every Nitrox/O2 regulator is assembled in a clean workshop, using compatible components and special lubricants. It is important to maintain the interior of the regulator in a clean state. Breathing air used in the production of a mixture should be oxygen compatible and double filtered with a hydrocarbon content not greater than 0.1 mg/m3. WARNING: Please check the regulations regarding Nitrox in your particular country as this may differ from Apeks standard policy. 17
18 Table 4 - Torque Specifications Part Number Description / Key Number Torque n/a n/a n/a Table 5 - Test Bench Specifications Test condition acceptable range Opening Effort External Leak High Pressure > 50 bar gauge Medium pressure 9.5±0.5 bar High Pressure > 50 bar gauge Medium Pressure 9.5±0.5 bar +1.4 to +1.6 in. H 2 0 (3.5 to 4.0 mbar) No Leaks allowed 18
19 FLIGHT 2nd STAGE Exploded Parts Diagram * All marked items must be replaced when serviced. 1 AP7589 Purge Clamp Ring Pewter AP7596/Y Apeks A Insert Logo Yellow AP7589/F Purge Clamp Ring Female 10 AP7579 Flight Venturi Lever AP7589/G Purge Clamp Ring Green 11* AP1267 O Ring AP7589/Nitrox Purge Clamp Ring Nitrox 12 APF Mouthpiece Clip AP7589/Y/M Purge Clamp Ring Male Octo 13 AP5324 Comforbite Mouthpiece AP7589/Y/F Purge Clamp Ring Female Octo AP1434/G Mouthpiece Green AP7589/TL Purge Clamp Ring Twilight APF Small Mouthpiece 2 AP0175/MALE Front Cover Assy 14 AP7581 Flight Spindle Body AP0175/F Front Cover Assy Female 15 AP2035 Lever AP0175/T Front Cover Assy Green 16* AP1154 O Ring AP0175-O Front Cover Assy Female Octo 17 AP7563 Valve Seat AP0175/TL Front Cover Assy Twilight 18 AP7586 Inlet Fitting 3 AP7577 Inner Locking Ring 19 AP7595 Locking Slide Ring 4 AP7592 Flight Friction Ring 20 AP7570 Micro Adjuster Screw Diaphragm 21 AP7582 Spindle Adjuster Sleeve 6 AP7590 Flight Case 22 AP7584 Spring Carrier 7 AP6223 Exhaust Valve 23 AP2021 Spring 8 AP7578 Flight Exhaust Tee 24* AP5711 O Ring 9 AP7596/B Apeks A Insert Logo Black 25 AP5707 Shuttle Valve AP7596/P Apeks A Insert Logo Pink 26* Silicone Seating (Grey) AP7596/G Apeks A Insert Logo Green 19
20 20
21 TECHNICAL SUPPORT FLIGHT SECOND STAGE REGULATOR MAINTENANCE Manual FOR AUTHORISED TECHNICIANS Apeks Marine Equpment Ltd Neptune Way, Blackburn, Lancs, England, BB1 2BT
DST & UST FIRST STAGE REGULATOR
TECHNICAL SUPPORT DST & UST FIRST STAGE REGULATOR MAINTENANCE MANUAL FOR AUTHORISED TECHNICIANS Document No. AP5824 Issue 3 9/12/2005 APEKS MARINE EQUIPMENT LTD, NEPTUNE WAY, BLACKBURN, LANCASHIRE. BB1
Apeks Second Stage Regulator Service & Repair Manual. for Authorized Sea Quest Service Centers. 2000 Sea Quest, Inc.
Apeks Second Stage Regulator Service & Repair Manual for Authorized Sea Quest Service Centers 2000 Sea Quest, Inc. Contents Introduction... 3 Safety Precautions... 3 General Procedures... 3 Maintenance
Dive Rite 200 & 300 Bar Isolator Manifold Service Manual
Dive Rite 200 & 300 Bar Isolator Manifold Service Manual Principal Photography and Text by Pete Nawrocky Copyright 2003 Lamartek Inc. D/B/A Dive Rite 0 Warning This manual is only to be used as a guide
APEKS TX 50 TECHNICAL MANUAL. Regulator REV 07/09
APEKS TX 50 Regulator TECHNICAL MANUAL REV 07/09 2 TX50 Technical Manual COPYRIGHT NOTICE This manual is copyrighted, all rights reserved. It may not, in whole or in part, be copied, photocopied, reproduced,
758 Heavy-duty Ratchet Guy Wire Cutter
INSTRUCTION MANUAL 758 Heavy-duty Ratchet Guy Wire Cutter Read and understand all of the instructions and safety information in this manual before operating or servicing this tool. Register this product
Installation Instructions 4508 4508S
SYMPHONY Spread Lavatory Faucet with Speed Connect Drain Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only on American Standard faucets. Speed Connect
MODEL G300 BRAKE BLEEDER
MODEL G300 BRAKE BLEEDER Installation, Operation & Repair Parts Information Branick Industries, Inc. 4245 Main Avenue P.O. Box 1937 Fargo, North Dakota 58103 REV060616 P/N: 81-0035G 1 THIS PAGE INTENTIONALLY
Regulator Owner s Manual DOC/0258/ENG ISSUE 1
Regulator Owner s Manual DOC/0258/ENG ISSUE 1 Copyright Notice This owner s manual is copyrighted, all rights reserved. It may not, in whole or in part, be copied, photocopied, reproduced, translated or
POWERLINE INFLATOR with DUAL-VALVE
Technical MAINTENANCE Manual POWERLINE INFLATOR with DUAL-VALVE 2 Contents Copyright notice...3 Introduction...3 Warnings, Cautions & Notes...3 Scheduled Service...3 General Guidelines...3 General Conventions...3
CONGRATULATIONS! TABLE OF CONTENTS. 1 Safety Warnings 2 About Your Wheels 3 Setting Up Your Wheels 7 Care and Cleaning 8 Warranty
WHEEL MANUAL CONGRATULATIONS! Congratulations on your purchase of Oval Concepts Wheels. Developed to perform at a high level, it is important that you follow the operation and maintenance instructions
San josé OWNER S MANUAL
San josé OWNER S MANUAL Assembling & operating manual San josé 30 mbar - PORTABLE GAS BARBECUE 1. 2. 3. Improper installation, adjustment, alteration, service or maintenance can injury or property damage.
tire inflator with pressure gauge
tire inflator with pressure gauge Model 95583 Assembly And Operation Instructions Due to continuing improvements, actual product may differ slightly from the product described herein. 3491 Mission Oaks
Cleaning Instructions for Burner, Pilot Assembly, and Emitter Screen. Series: 150000 200605 LP Gas
Cleaning Instructions for Burner, Pilot Assembly, and Emitter Screen Series: 150000 200605 LP Gas Tools needed Bottle brush Non-abrasive scouring pad Small utility brush Heavy-duty pipe cleaners Air hose
Unit: mm(in) Item Standard value Service limit Axle shaft run out - 0.2(0.008)
Rear Wheel/Brake/Suspension 13. Rear Wheel/Brake/Suspension Service Information 13-1 Troubleshooting 13-2 Rear Wheel 13-3 Rear Cushion 13-4 Rear Swing Arm 13-7 Service Information General Safety If the
Air-Oxygen Blender. Service Manual. Model No. PM5200 Series PM5300 Series (shown)
Service Manual Model No. PM5200 Series PM5300 Series (shown) SAVE THESE INSTRUCTIONS 300 Held Drive Tel: (+001) 610-262-6090 Northampton, PA 18067 USA Fax: (+001) 610-262-6080 www.precisionmedical.com
10 TON HYDRAULIC PRESS
10 TON HYDRAULIC PRESS Model Nos. CSA10F and CSA10B OPERATING & MAINTENANCE INSTRUCTIONS 0200 SPARE PARTS and SERVICING Please contact your nearest dealer, or CLARKE International, on one of the following
Professional Precharged Hunting Rifle
TRIGGER ADJUSTMENT. The trigger is set at the factory, but some aspects can be adjusted to suit individual preferences. 1. This screw adjusts the weight of second stage trigger pull, to increase the weight
This instruction is valid for all ACD pump models shown on page 2
Screw pumps ACD Maintenance and Service Instruction This instruction is valid for all ACD pump models shown on page 2 Contents Page List of components 2 Exploded view/ordering code 3 Service intervals
WARNINGS AND IMPORTANT INFORMATION 3
REGULATORS Table of Contents S AND IMPORTANT INFORMATION 3 CE Certification, Scuba Definitions and Limits 4 EN250: 2000 Regulations 4 Definition of SCUBA 4 Limitations Provided by EN250: 2000 5 Regulator
Lenntech. 1000 psi End port pressure vessels 2.5. User s Guide to: Phoenix Vessel Technology Limited. Model number: 1503
1 User s Guide to: Phoenix Vessel Technology Limited 1000 psi End port pressure vessels 2.5. Model number: 1503 Lenntech [email protected] Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 Phoenix
PET-10 INSTRUCTION MANUAL PRESSURE TANK
INSTRUCTION MANUAL PRESSURE TANK PET-10 This manual contains IMPORTANT WARNINGS and INSTRUCTIONS. Equipment in this manual is exclusively for painting purposes. Do not use for other purposes. The operator
Cleaning Instructions, Pilot Replacement and Valve Change. Model No.: 233010 Natural Gas
Cleaning Instructions, Pilot Replacement and Valve Change Model No.: 233010 Natural Gas 8mm open-end wrench 9mm open-end wrench 10mm open-end wrench 12mm open-end wrench 13mm open-end wrench Phillips screw
Rebuild Instructions for 70001 and 70010 Transmission
Rebuild Instructions for 70001 and 70010 Transmission Brinn, Incorporated 1615 Tech Drive Bay City, MI 48706 Telephone 989.686.8920 Fax 989.686.6520 www.brinninc.com Notice Read all instructions before
Auto-belay Cable Replacement Process
Auto-belay Cable Replacement Process Version 2.00 WARNING: The air pressure in the auto-belay system is what causes the cable to be retracted when releasing the cable or climbing the wall with the cable
Front brakes (FN- 3), servicing
j a t Front brakes (FN- 3), servicing 46-1 Front brakes, servicing Note: Install complete repair kit. After replacing brake pads and before moving vehicle, depress brake pedal several times firmly to properly
BACKPACK SPRAYERS. MODEL NOS: KSP16 & KSP20 Part Nos: 3402270 & 3402275 OPERATING & MAINTENANCE INSTRUCTIONS GC04/12
BACKPACK SPRAYERS MODEL NOS: KSP16 & KSP20 Part Nos: 3402270 & 3402275 OPERATING & MAINTENANCE INSTRUCTIONS GC04/12 INTRODUCTION Thank you for purchasing this CLARKE Sprayer, designed for use only with
300 SERIES 331, 332, 333, 344, 356 AND 367 MODELS
Section: MOYNO 500 PUMPS Page: 1 of 8 Date: March 1, 1998 SERVICE MANUAL MOYNO 500 PUMPS 300 SERIES 331, 332, 333, 344, 356 AND 367 MODELS Mechanical Seal Models Packing Gland Models MODELS DESIGN FEATURES
MODEL J SERIES CONVERTER
3030 S Susan Street, MODEL J SERIES CONVERTER REPAIR KIT INSTRUCTIONS Important: Any maintenance, service or repair should be performed by trained and experienced service technicians. Proper tools and
2012 Aqua Lung International, Inc. Regulator Owner s Manual, P/N 127861 rev. 02/12
R e g u l a t o r O w n e r Ê s M a n u a l Regulator OwnerÊs Manual Copyright This owner s manual is protected by the law of 11 March 1957 concerning literary and artistic property. It may not, in whole
#12 Professional Meat Grinders
#12 Professional Meat Grinders MG-203100 (52021040) Manual Instruction Thank you, and congratulations on purchasing the Non-corrosive electric meat grinder. Your grinder comes complete with everything
Regulator Owner s Manual DOC/0258/US ISSUE 9
Regulator Owner s Manual DOC/0258/ ISSUE 9 1 Copyright Notice This owner s manual is copyrighted, all rights reserved. It may not, in whole or in part, be copied, photocopied, reproduced, translated or
TECHNICAL BULLETIN. Meritor WABCO Cab Leveling Valves and Chassis Leveling Valves. How the Cab Leveling and Chassis Leveling Valves Work
Revised 02-00 TECHNICAL BULLETIN Meritor WABCO Cab Leveling Valves and Chassis Leveling Valves This technical bulletin covers both cab and chassis leveling valves manufactured by Meritor WABCO. While the
Assembly and Usage Instructions
Assembly and Usage Instructions A Product 5885 West Van Horn Tavern Road Columbia, MO 65203 www.caldwellshooting.com Instruction #1001667 Limited Warranty Every Caldwell product is warrantied to be free
Instruction Manual. Alfa Laval SB Membrane Sample Valve ESE02963-EN1 2015-10. www.sks-online.com www.sks-webshop.com.
Instruction Manual Alfa Laval SB Membrane Sample Valve ESE02963-EN1 2015-10 Original manual Table of contents The information herein is correct at the time of issue but may be subject to change without
SCREAMIN' EAGLE "HEAVY BREATHER" PERFORMANCE AIR CLEANER KIT
REV. 05-04- SCREAMIN' EAGLE "HEAVY BREATHER" PERFORMANCE AIR CLEANER KIT GENERAL Kit Numbers 95-08B, 9006-09B, 876-0A Models For model fitment information, see the P&A Retail Catalog or the Parts and Accessories
DANGER DANGER. General Information. Safety Is Your Responsibility. Ordering Parts. Contact Information
Safety Safety Is Your Responsibility DANGER To avoid personal injury or death, carefully read and understand all instructions pertaining to the Anthony Liftgates product. Do not attempt to install, operate,
Drive shaft, servicing
Volkswagen Passat B6 - Drive shaft, servicing Стр. 1 из 41 40-7 Drive shaft, servicing Drive shafts, overview I - Assembly overview: Drive axle with CV joint VL100 40-7, Drive axle with CV joint VL100,
Stainless Steel Single and Dual Circulation Kits
Instruction Sheet P/N 160780 01 Stainless Steel Single and Dual Circulation Kits Introduction The single and dual high-pressure circulation kits allow you to vary and control the circulation rate of coating
INSTRUCTIONS. FLHR/C/S (Road King) FRONT END LOWERING KIT 1WARNING -J03242 REV. 10-19-04. General. Removal (Left and Right Forks) Kit Number 54614-05
INSTRUCTIONS -J04 REV. 0-9-04 General FLHR/C/S (Road King) FRONT END LOWERING KIT This kit is designed for installation on 00 and later FLHR/C/S Model Motorcycles. Road King models use the conventional
S&G Model 2937 Group 1 Combination Lock
Installation and Combination Changing Instructions S&G Model 2937 Group 1 Combination Lock NOTE: READ COMPLETE INSTRUCTIONS BEFORE INSTALLATION These instructions should be followed when installing the
1.8 CRANKSHAFT OIL SEALS
SERIES 60 SERVICE MANUAL 1.8 CRANKSHAFT OIL SEALS An oil seal is fitted between each end of the crankshaft and the bores of the flywheel housing and gear case cover to retain the lubricating oil in the
Back Pack Sprayer. Operator's Manual MODELS MS - 40 MS - 50
Back Pack Sprayer Operator's Manual MODELS MS - 40 MS - 50 WARNING DANGER Read rules for safe operation and all instructions carefully. ECHO provides this Operator's Manual which must be read and understood
OWNER S MANUAL Table Tennis Table Patent Pending
OWNER S MANUAL Table Tennis Table Patent Pending Be sure to write your model number and serial number here for future reference. You can find these numbers printed on the bottom of the table. MODEL # T8179
Trillium 40 Axis Spring Tensioner Wire Replacement Instructions
Trillium 40 Axis Spring Tensioner Wire Replacement Instructions 1 Overview The objective is to replace the broken axis spring tensioner wire. This requires the following tasks: 1. Remove the seismometer
ARVINMERITOR UNITIZED FRONT WHEEL HUB INSPECTION AND MAINTENANCE
SERVICE BULLETIN (Also applies to Mack Trucks Australia) NUMBER: SB-423-002 DATE: 8/23/02 MODEL: All with FF981 Front Axle ARVINMERITOR UNITIZED FRONT WHEEL HUB INSPECTION AND MAINTENANCE The ArvinMeritor
Not required for most applications Not required for most applications High pressure (12-803 provided) High pressure (12-803 provided)
ELECTRIC FUEL PUMPS P/N 12-801-1, 712-801-1, 12-802-1, 712-802-1, 12-815-1, & 712-815-1 FUEL PRESSURE REGULATORS P/N 12-803, 12-501, 12-804, 12-500, & 15812NOS Installation Instructions THESE INSTRUCTIONS
Installation, Operating and Maintenance Instructions for AEON Metal Seated Gate Valve (MSGV) Water
1 Foreword 1.1 Thank you for choosing one of the range of AEON's BS standard valves. For safety purposes, the user shall read this instruction to fully understand the operation of the product. 2 AEON Design
Rear wheel brakes, servicing. Стр. 1 из 45. Note:
Volkswagen Touareg - Rear wheel brakes, servicing Стр. 1 из 45 46-2 Rear wheel brakes, servicing Rear brakes, FN 44 brake caliper, servicing Note: After replacing brake pads, depress brake pedal firmly
AXLE SHAFTS - FRONT. 1998 Pontiac Bonneville MODEL IDENTIFICATION DESCRIPTION & OPERATION TROUBLE SHOOTING REMOVAL & INSTALLATION
AXLE SHAFTS - FRONT 1998 Pontiac Bonneville 1998-99 DRIVE AXLES FWD Axle Shafts - Cars - "C", "G" & "H" Bodies GM Aurora, Bonneville, Eighty Eight, LeSabre, LSS, Park Avenue, Regency, Riviera MODEL IDENTIFICATION
Round Housing with Side Ports
Power Steering Steering Control Unit (SCU) Parts and Repair Information 5 Series Steering Control Units 001 Square Housing with Side Ports Round Housing with Side Ports T E L RP Round Housing with End
WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!
WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU! Atlanta (Monroe) GA 770-267-3787 [email protected] www.gpmhydraulic.com What You Don t Know About Hydraulic Accumulators Can Kill You TABLE OF CONTENTS
Trunnion-Design Ball Valves
Trunnion-Design Ball Valves 12" 20" (DN 300 500) Series 7150 12" (DN 300) Series 730S 12" 20" (DN 300 500) Series 7300 14" 24" (DN 350 600) Series 9150 14" 24" (DN 350 600) Series 9300 Installation, Maintenance
Tech. Services: (800) 477-8326 Fax: (800) 765-8326 Order Entry: (800) 541-1418 Fax: (800) 288-7031 Internet Address: http://www.powerteam.
ORIGINAL INSTRUCTIONS Form No.102842 5 SPX Hydraulic Technologies 5885 11th Street Rockford, IL 61109-3699 USA Tech. Services: (800) 477-8326 Fax: (800) 765-8326 Order Entry: (800) 541-1418 Fax: (800)
HYDRAULIC LIFT TABLE CART 2200-LB.
HYDRAULIC LIFT TABLE CART 2200-LB. OWNER S MANUAL WARNING: Read carefully and understand all MACHINE ADJUSTMENT AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other
Owner s Manual Read and keep this manual. Patents World Wide
Owner s Manual Read and keep this manual. Patents World Wide S & S Industries, Inc., Sarasota, FL, USA www.trail-gator.com Copyright 2008 All Rights Reserved The following manual is provided to assist
15GAL STEEL OIL DRAIN WITH 110V PUMP
15GAL STEEL OIL DRAIN WITH 110V PUMP OWNER S MANUAL WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety
orlando OWNER S MANUAL
orlando OWNER S MANUAL 2 Assembling & operating manual Orlando 30 mbar - PORTABLE GAS BARBECUE 1. 2. 3. Improper installation, adjustment, alteration, service or maintenance can injury or property damage.
IMPORTANT DOCUMENTATION DO NOT DISCARD!
PART NO.: 6441-263C SERIES GRT 3 JAW PARALLEL GRIPPERS INFORMATION SHEET IMPORTANT DOCUMENTATION DO NOT DISCARD! Use this information sheet to assist with gripper installation and setup. File with maintenance
123 Industrial Loop Road Paynesville, MN 56362 Phone: 1-800-864-1649 www.master-mfg.com
123 Industrial Loop Road Paynesville, MN 56362 Phone: 1-800-864-1649 www.master-mfg.com INTRODUCTION The purpose of this manual is to assist you in the assembly, operation and maintenance of your sprayer
STEERING HANDLEBAR/FRONT WHEEL/ FRONT SHOCK ABSORBER
14 14 STEERING HANDLEBAR/FRONT WHEEL/ SCHEMATIC DRAWING ------------------------------------------------- 14-1 SERVICE INFORMATION------------------------------------------------ 14-2 TROUBLESHOOTING-----------------------------------------------------
REPAIR INSTRUCTIONS UNDER BODY CYLINDER (UM, UL)
Table of contents 1. Introduction... 3 1.1. Scope of use... 3 1.2. General remarks... 3 1.3. Contact Hyva... 3 1.4. Precautions... 4 1.5. Spare parts... 4 1.5.1. Prior to use... 4 1.6. Recycling and Reuse
SCREAMIN' EAGLE "HEAVY BREATHER" PERFORMANCE AIR CLEANER KIT
REV. 2015-04-23 SCREAMIN' EAGLE "HEAVY BREATHER" PERFORMANCE AIR CLEANER KIT GENERAL Kit Numbers 29299-08, 29098-09 Models For model fitment information, see the P&A Retail Catalog or the Parts and Accessories
Char-Lynn Hydraulic Motor. Repair Information. 10 000 Series. October, 1997
Char-Lynn Hydraulic Motor October, 1997 Repair Information Geroler Motor Two Speed 001 27 Retainer inside bore of valve plate bearingless motors only 4 15 16 3 6 35 Parts Drawing 25 2 2 1 19 17 36 40 47
Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47)
47 Brakes - Hydraulic Components (Page GR-47) FS III front brake calipers, servicing Front brake caliper piston, removing and installing FN 3 front brake calipers, servicing Front caliper piston, removing
REPAIR AND MAINTENANCE MANUAL
REPAIR AND MAINTENANCE MANUAL Professional Pest Control Application Equipment Prime Line Sprayers B&G Equipment Company 135 Region South Drive, Jackson, GA 30233 800.544.8811 Phone 678.688.5601 Fax 678.688.5633
Manual for GlobePharma Mini-Press II Rotary Tablet Press
1 of 13 Preparing the Rotary Press 1. Make sure the rotary press is unplugged. 2. Open the bottom cabinet of the rotary press and take out the grey tool kit, and the beige box of punches and dies. 3. Take
SAFETY & OPERATING INSTRUCTIONS
SAFETY & OPERATING INSTRUCTIONS EDLUND TOMATO LASER, Models ETL -316, -140 & -380 READ AND UNDERSTAND THIS MANUAL AND ALL INSTRUCTIONS BEFORE OPERATING THIS SLICER. 159 Industrial Parkway, Burlington,
STORAGE, INSTALLATION AND MAINTENANCE PROCEDURES
GATE VALVE O.S. & Y 1.0 Periodic Inspections 1.1 The valve stem packing should be inspected at least monthly. If the stem packing shows signs of leakage, simply tighten the adjusting nuts to compress the
2006 HEADSHOK Service Video #1
LEFTY SPEED DLR DAMPING CARTRIDGE This document explains how to properly remove, disassemble, inspect, reassemble and reinstall the Lefty Speed DLR2 damping cartridge. It is a document to be used in conjunction
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE
INSTALLATION & OPERATING INSTRUCTIONS
INSTALLATION & OPERATING INSTRUCTIONS WARNING RISK OF ELECTRIC SHOCK. CONNECT ONLY TO A CIRCUIT PROTECTED BY A GROUND-FAULT CIRCUIT-INTERRUPTER. THE UNIT SHOULD BE INSTALLED BY A QUALIFIED SERVICE REPRESENTATIVE.
Code of Practice for the Manual Handling of Gas Cylinder and exchange of regulators
Code of Practice for the Manual Handling of Gas Cylinder and exchange of regulators General information The Manual Handling Operations Regulations 1992 (updated 1998) came into force in January 1993. The
Float and Thermostatic Traps Series H, C and X
Hoffman Specialty Installation & Maintenance Instructions HS-(E) and Thermostatic Traps Series H, C and X Series C & NPT Series C NPT Series X NPT Series C NPT Series H Ratings Maximum Max. Operating NPT
HT-0095 Mini PV Receptacles 22-32 AWG Crimping Hand Tool. Tool P/N HT-0095
HT-0095 Mini PV Receptacles 22-32 AWG Crimping Hand Tool Tool P/N HT-0095 FCI MANUAL P/N 415988-001 Issued: Date (03/12/99) Page 1 of 18 HT-0095 Issued: Date (03/12/99) Page 2 of 18 Introduction Table
Char-Lynn Spool Valve Hydraulic Motors. Repair Information. W Series Geroler Motors
Char-Lynn Spool Valve Hydraulic Motors Repair Information W Series Geroler Motors with Parking Brake 004 Nut Key Ring, Retaining Bearing Ring, Retaining Ring, Retaining Washer (Thick), Pressure Washer,
TOYOTA Tundra 2007 - BACK-UP CAMERA SYSTEM Preparation
Preparation Part Number(s): PT233-34070, PT923-35070-11, PT923-35070-43 NOTE: Part number of this accessory may not be the same as part number shown. Back Up Monitor Kit Contents PT923-35070-11 / PT923-35070-43
Tri-Homo Style Operation and Maintenance Instructions
Tri-Homo Style Operation and Maintenance Instructions One Research Drive Stratford, CT 06615 (203) 375-0063 www.sonicmixing.com 1 Installation and Start-up Do not perform following adjustments without
OPERATION AND MAINTENANCE MANUAL 5-1/4 B-84-B-5 FIRE HYDRANT
OPERATION AND MAINTENANCE MANUAL 5-1/4 B-84-B-5 FIRE HYDRANT INDEX AMERICAN - DARLING 5-1/4 IN. B-84-B-5 FIRE HYDRANT OPERATION AND MAINTENANCE MANUAL OPERATION AND MAINTENANCE REPAIRS Operation and Maintenance...
INSTALLATION MANUAL MODEL RP-100
INSTALLATION MANUAL FOR 24 VALVE 5.9L CUMMINS POWERED DODGE TRUCKS 2003 THROUGH 2004.5 MODEL RP-100 READ THESE INSTRUCTIONS THOROUGHLY BEFORE BEGINNING INSTALLATION 5400 BUSINESS 50 WEST SUITE 8 573 635-0555
Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer
Overview READ ENTIRE INSTRUCTIONS BEFORE STARTING INSTALLATION PARTS LIST A. Flush valve B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve
Installation and Operating Instructions Installation Instructions for SS EPE-316L Series
INSTR3010 0406 Installation and Operating Instructions Installation Instructions for SS EPE-316L Series Congratulations on your purchase of this Aqua-Pure high flow, single housing filtration system. This
DeZURIK 3-20" BAW AWWA BUTTERFLY VALVES WITH TRANSFER MOLDED SEAT
3-20" BAW AWWA BUTTERFLY VALVES WITH TRANSFER MOLDED SEAT Instruction D10386 August 2013 Instructions These instructions provide installation, operation and maintenance information for BAW Butterfly Valves.
HAND PUMP OPERATION, SERVICE AND PARTS INSTRUCTION MANUAL
OPERATION, SERVICE AND PARTS INSTRUCTION MANUAL 767 HAND PUMP Read and understand this material before operating or servicing this equipment. Failure to understand how to safely operate this tool could
TUTORIAL. REbUILdING. front CALIpER O-RING CONVERSION CORVETTE 1965-82. Part #: HT-1
Part #: HT-1 1965-82 CORVETTE O-RING CONVERSION front CALIpER REbUILdING TUTORIAL Choosing a Brake Caliper Rebuild Kit Standard Lip Seals vs. O-Ring Seals Lip seal design seals are used on 1965-1982 Corvette
http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html
http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html TECHNICAL SERVICE DEPARTMENT Removal, Cleaning, & Reinstallation of the Burner Assembly For models 74 & GT199 Required tools -
Cleaning Instructions for Burner, Pilot Assembly, and Emitter Screen Series: 220000-450000
Cleaning Instructions for Burner, Pilot Assembly, and Emitter Screen Series: 220000-450000 10 mm open end wrench 12 mm open end wrench 9/16 open end wrench 5/8 open end wrench 11/16 open end wrench 9/16
POSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT
POSEION 2-29, 2-25 & 2-22 POSEION 2-29, 2-25 & 2-22 XT Repair Manual Index A. Safety precautions 3 B. Technical data 4 C. Structure 5-6. Service / Repair 7-23 E. Tools 24 F. Function 25-26 G. Electric
Model MS-41BP 4G/ 15L. WARNING Carefully Read These Instructions Before Use 013529 R0514
Backpack Sprayer Use and Care Manual Model MS-41BP 4G/ 15L WARNING Carefully Read These Instructions Before Use 013529 R0514 WARNING WARNING: Improper use or failure to follow instructions can result in
CHROME FRONT BRAKE MASTER CYLINDER KIT
-J075 REV. 009-0-0 CHROME FRONT BRAKE MASTER CYLINDER KIT GENERAL Kit Number 5-99D, 5-99D Models These Chrome Master Cylinder Kits are designed to replace the original equipment front brake master cylinder
BETTIS CONVERSION INSTRUCTIONS TO CONVERT HD SERIES ACTUATORS TO HD-M3, HD-SR-M3 HD-M3HW OR HD-SR-M3HW SERIES PNEUMATIC ACTUATORS
BETTIS CONVERSION INSTRUCTIONS TO CONVERT HD SERIES ACTUATORS TO HD-M3, HD-SR-M3 HD-M3HW OR HD-SR-M3HW SERIES PNEUMATIC ACTUATORS PART NUMBER: 132581 REVISION: A RELEASE DATE: 24 March 2000 Page 1 of 10
This is the civilian transfer case with the cooling loop only found in the driven gear half of the front case.
INTRODUCTION The Transfer case used in the AMG Hummer is a New Venture Gear, model 242. This case has been in use for the H-1/Hummer since the early 1990 s. There have been modifications to the internal
Instructions for Using the Watch Works Tool Kit to Change a Watch Battery
Instructions for Using the Watch Works Tool Kit to Change a Watch Battery Click on this link http://www.allamericanwatches.com/site/626101/product/e2306-a to purchase the Watch Battery Replacement Tool
Strut Spring Compressor
Strut Spring Compressor Item 43753 Read this material before using this product. Failure to do so can result in serious injury. SAVE THIS MANUAL. When unpacking, make sure that the product is intact and
SET-UP AND INSTALLATION FOR LEAD SCREW CARTRIDGE ASSEMBLY
SET-UP AND INSTALLATION FOR LEAD SCREW CARTRIDGE ASSEMBLY 82-13-1 O-Ring (Rear) The Lead Screw Assembly is shipped separately. Note: Install Electrical and Pneumatic Circuitry. Be Sure electrical and pneumatic
SHOT BLAST CABINET MODEL NO: CSB20B
SHOT BLAST CABINET MODEL NO: CSB20B PART NO: 7640110 USER INSTRUCTIONS GC0216 INTRODUCTION Thank you for purchasing this CLARKE Shot Blast Cabinet which is designed for professional workshop use. Before
MODEL T200-F18 MODEL T125-F18 Finish Nailers
P MODEL T200-F18 MODEL T125-F18 Finish Nailers IMPORTANT! DO NOT DESTROY It is the customer s responsibility to have all operators and service personnel read and understand this manual. OPERATING MANUAL
SBC90. Abrasive Blast Cabinet Assembly & Operating Instructions
SBC90 Abrasive Blast Cabinet Assembly & Operating Instructions READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. This manual provides important
INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX
Fan Coil Replacement Coil Kit EBX & EBXX These instructions must be read and understood completely before attempting installation. These instructions covers the installation of replacement coil kit into
Flat Bottom Long Ram Hydraulic Jack
Flat Bottom Long Ram Hydraulic Jack 3 Ton 8 Ton 36468 36469 ASSEMBLY & OPERATING INSTRUCTIONS 349 Mission Oaks Blvd., Camarillo, CA 930 Visit our Web site at http://www.harborfreight.com TO PREVENT SERIOUS
