WARNINGS AND IMPORTANT INFORMATION 3
|
|
|
- Daniel Osborne
- 9 years ago
- Views:
Transcription
1 REGULATORS
2 Table of Contents S AND IMPORTANT INFORMATION 3 CE Certification, Scuba Definitions and Limits 4 EN250: 2000 Regulations 4 Definition of SCUBA 4 Limitations Provided by EN250: Regulator Systems 5 Definition of First Stage 5 Definition of Second Stage 5 Diving with Halcyon Regulators 6 Setting up your Regulators 6 Post Dive 7 Cold Water Use 7 Specifications 8 Halcyon First Stage Features 9 Halcyon Second Stage Features 10 Comparison Chart 11 Regulator Care and Maintenance 11 Storage Guidelines 12 Maintenance 12 Nitrox 12 Use of Nitrox Outside the European Community 12 Use of Nitrox Within the European Community 13 Main Features of Nitrox Dedicated Regulators 13 Nitrox Regulator Use and Maintenance Notes 14 Halcyon Warranty Information 14 2
3 3 S AND IMPORTANT INFORMATION Warning indicates a potentially hazardous situation that, if not avoided, could result in serious injury or death. Caution indicates a potentially hazardous situation that, not avoided, may result in minor or moderate injury. It may also alert against unsafe practices. Before using the equipment, thoroughly read and understand all the instructions and warnings contained in this manual. The equipment is limited to the uses described in this manual. Any other applications of equipment use will require written approval by Halcyon Manufacturing. Halcyon regulators are not intended for use by persons who are untrained and may not know the hazards and risks of scuba diving. CAUTION The content of this manual is based upon the latest information available at the time of printing. Halcyon reserves the right to make changes at any time. Halcyon refuses all responsibility for damages caused by non-compliance with the instructions contained in this manual. These instructions do not extend the warranty or the responsibilities stated by the terms of sale and delivery by Halcyon Manufacturing. CAUTION Should the equipment be serviced or repaired without complying with procedures approved by Halcyon or by untrained personnel not certified by Halcyon, or should it be used in ways and for purposes other than specifically designated, liability for the correct and safe function of the equipment transfers to the owner/user.
4 Diving in cold water requires special equipment and techniques. We strongly recommend you obtain appropriate levels of training from a recognized training agency before diving in cold waters. If the equipment will be used in cold water (temperatures lower than 10 C (50 F)), it will be necessary to use a regulator suited for such temperatures. Halcyon regulators are not medical devices nor intended for medical use. They must not be used to supply treatment oxygen in any medical emergency. CE CERTIFICATION AND SCUBA DEFINITIONS AND LIMITS All Halcyon regulators described in this manual have obtained the CE certification in compliance with European directive 89/686/EEC. Certification tests have been conducted according to the specifications set by the said directive, regulating the conditions for the release on the market and the fundamental safety requirement for category III Personal Protective Equipment (PPE). The applicable CE mark certifies compliance with the fundamental requirements for health and safety. The 0098 number next to the CE marking is the identification code for Germanischer Lloyd, the notified body controlling production compliance with regulations, as per Art. 11 A ED 89/686/EEC. EN250: 2000 Regulations and What They Mean The requirements and tests defined by the EN 250: 2000 aim to ensure a minimum safety level for the operation of underwater breathing equipment. In Europe, the EN 250: 2000 defines the minimum technical standards of acceptance for recreational diving regulators. All HALCYON regulators have successfully passed the certification test required by this standard. Definition of SCUBA According to EN250: 2000 EN250: 2000 defines a SCUBA unit as a self-contained open-circuit underwater breathing apparatus. A SCUBA unit can be composed of component groups. SCUBA minimum required component groups are elements 1) to 5) of the following list: 1. cylinder(s) with valve(s); 2. demand regulator(s); 3. safety device(s); 4. face mask: complete mouthpiece or half-mask for diving or diving helmet; and a 5. carrying system. A SCUBA unit in compliance with the requirements of the EN250 is designed to supply only one diver at a time. If the SCUBA unit is used by more than one diver, simultaneously, breathing and cold water performance may no longer satisfy the requirements set forth by EN250. 4
5 Limitations Provided by EN250: 2000 The SCUBA unit can be comprised of separate components such as: cylinder(s), regulator(s), and submersible pressure gauge. The Halcyon regulators described in this manual can be used with SCUBA components units certified according to directive 89/686/EEC and EN250: The air contained in the cylinder must comply with the requirements for breathable air defined by EN The maximum operating depth is 50 meters (164 ft.) however divers must conform to the limits set by local regulations in force at the diving location. REGULATOR SYSTEMs REGULATORS A regulator system is required to reduce the pressure of the compressed air contained in the cylinder to an ambient pressure in order to supply breathable air when needed. It is also possible to connect pressure gauges (analog or digital), IP inflators to supply buoyancy compensators, dry suits, and other devices to this system. The regulator system is composed of a pressure reduction device and one or more breathing devices. In this manual, the pressure-reducing device and the breathing device will be indicated, respectively, by the terms first stage and second stage. Definition of First Stage A pressure-reducing mechanism that reduces the pressure of the compressed air contained in the cylinder to an intermediate relative pressure of about 9.5bars (138psi). The first stage uses a balanced piston or diaphragm mechanism. All Halcyon first stages are delivered with DIN477/50 screw fittings (300-bar max pressure) for use with up to 40% Nitrox (allowed outside of the European Community). Definition of Second Stage This second stage is supplied with the intermediate pressure coming out of the first stage through the low-pressure hose. The second stage then reduces the pressure to ambient pressure during the inhalation phase. The second stage may be balanced or unbalanced and equipped with an Air Control Vane (A.C.V.). An example of a complete regulator with a DIN first stage: 5 1 First stage with DIN connection 2 Second stage 3 DIN inlet protective cap 4 DIN retaining wheel 5 Rotating swivel 6 High-pressure port 7 Purge button 8 Exhaust deflector 9 Inhalation resistance control 10 A.C.V. control 11 Low-pressure ports Image 1. Regulator diagram
6 All Halcyon regulators can be identified via a serial number. The number is printed on the housing of the second stage and on the metal body of the first stage. Halcyon offers a lifetime warranty to the original owner of all Halcyon regulators. This warranty covers material and manufacturing defects (with the exception of consumable materials such as O-rings, seats, filter, mouthpiece, and low-pressure hoses). In order to maintain this warranty, it is mandatory to perform annual service on the regulator by an Authorized Halcyon Dealer service facility and maintain proof of service records. For details on the warranty, please consult a Halcyon Authorized Dealer. DIVING WITH HALCYON REGULATORS Setting Up Your Regulators Before assembling the SCUBA units, verify that all components comply with local or European standards. Prior to connecting the first stage to the cylinder, verify that the connection is free from dirt (sand, debris) and that the O-ring is undamaged. If using an adapter with your DIN connection, check to see it is free from dirt or debris before fitting it to the cylinder valve. Check that the contact surfaces are in the correct position and then tighten the yoke screw. DIN connection: Screw the first stage connector on the cylinder valve after checking that this is also free from dirt or debris. Before tightening the hand-wheel and while screwing it in, confirm that the threads on the DIN connection and on the valve correspond correctly and are not crossed (see Image 2). In order to obtain the maximum comfort, the low-pressure hose connecting the first stage to the second stage should be horizontal and directed toward the diver s right shoulder. Be sure the SCUBA system is fit properly (refer to the appropriate user instruction guide). After fitting the SCUBA system, be sure the cylinder is secure and can t work its way loose. When opening the valve cylinder the second stage purge button should be slightly depressed, so that the second stage valve is open. This purge procedure should not be used in colder temperatures (lower than 10 C (50 F)) where the gas flow can encourage regulator freezing. Vacuum leak test: With the cylinder valve closed, slowly inhale from the second stage. It should be possible to achieve and maintain a minimal negative pressure without air entering the system. This test must be repeated for all regulator second stages connected to the SCUBA unit in use. High-pressure leak test: Depress the purge slightly while slowly opening the cylinder valve; release the purge and continue opening the valve. With the system pressurized, check for any leaks and read the pressure registered on the pressure gauge. Close the cylinder valve and check the pressure gauge. The displayed pressure should not decrease over the first minute. Image 2. DIN connection to cylinder. Reopen the valve. Check the entire SCUBA unit by performing several complete breathing cycles (deep inhalation/ exhalation) with the cylinder valve open and the second stage mouthpiece in the mouth. Check that all devices connected to the SCUBA unit are operating correctly. For example, check that the buoyancy compensator inflator (or the dry suit inlet valve) is functioning, etc. While opening the cylinder valve, the pressure gauge face should be directed away from all parties to avoid injury in the event of a failure. 6
7 7 Never connect a low-pressure hose to a high-pressure port. These connection threads are different sizes and are not compatible. Do not use adapters of any kind to connect low-pressure devices to high-pressure ports. Doing so could cause serious damage to both the user and equipment. Post Dive Close the cylinder valve and drain the regulator system by pushing on the purge button of each second stage. After the system has been depressurized, disconnect the first stage regulator from the valve. All first stage inlets must be closed with the provided protective caps to avoid the entry of debris, dirt, or moisture (see Image 3). Image 3. Protective cap on DIN inlet Diving in cold water requires special equipment and techniques. Before diving in cold water, we strongly recommend you obtain adequate training from a recognized training agency. Cold Water Use EN250: 2000 norm defines cold waters as those having a temperature lower than 10 C (50 F) and requires that regulators certified for use in such conditions must be tested and approved to work properly in temperatures of 4 C (39 F). If the SCUBA equipment is used in water with a temperature lower than 10 C (50 F), it is important to keep in mind the following: 1. Use only regulators certified in these conditions. Halcyon regulators are certified for use in cold water in accordance with norm EN250: Prior to the dive, keep the regulator in a warm environment before fitting your regulator on the tank. 3. If the regulator is exposed to colder conditions, much lower than 0 C (32 F), set the A.C.V. control on predive to avoid the risk of spontaneous and uncontrolled free-flow. 4. With high air flows, the regulator first stage cools rapidly; therefore avoid high consumption rates during cold water dives. For example, avoid simultaneously using the buoyancy compensator and dry suit inflator and the alternate air source. It s also advised to avoid checking the second stage function via the purge button, unless absolutely necessary. Ensure that the cylinder is filled only with air compliant with norm EN In extremely cold water diving, Halcyon recommends the use of a cylinder equipped with two separate valves, connected to two complete regulators. Do not push down on the purge button in low temperatures, as this may cause a second stage freeze-up.
8 The presence of moisture in the cylinder will cause corrosion of the cylinder and it may cause freezing and subsequent malfunction of the regulator during dives carried out in cold water temperatures (lower than 10 C (50 F)). Cylinders must only be filled with atmospheric compressed air, according to the EN12021 norm. Other gases must comply with the appropriate governing regulations. For example, the use of nitrox in Europe is regulated by EN13949 and EN Cylinders must be transported according to local rules provided for the transport of dangerous goods. Cylinder use is subjected to the laws regulating the use of gases and compressed air. Image 4. Diaphragm first stage regulator 1. H-50D DIN first stage 2. Dry balance chamber 3. Protective cap 4. DIN retaining wheel 5. DIN inlet, with protective cap DIN uses a threaded connection complying with ISO norm (300-bar). YOKE Adapter: Halcyon regulators can be used with a yoke adapter.* This is composed of a yoke and screw and can be used up to 230-bar, according to the ISO norm. *Halcyon does not sell a yoke adapter. The regulators will fit any standard yoke adapter. SPECIFICATIONS The main technical features of Halcyon regulators are detailed below. To verify which of these features apply to any specific first and second stage combination, refer to the tables at the end of this chapter. Halcyon First Stage Features Balanced Piston First stages with air-balanced pistons offer unaffected performance with changing tank pressure and deliver more air to the second stage than any other first stage design. A balanced system has ultra-fast breathing response, instant air-on-demand delivery, and extra high air flow, due to the use of lighter and more sensitive components. 8
9 9 Freeze Resistant Piston Design Halcyon piston regulators are designed with a special heat-retaining cold water piston, featuring a Teflon coated spring to aid in antifreeze protection. These features aid in heat retention from the cooling affects of a gas pressure drop. Rotating Swivel on Piston Configuration Allows optimal hose positioning to reduce jaw fatigue. This feature allows all inter-stage pressure hoses attached with the swivel to rotate in the best possible position for the diver. Balanced Diaphragm Balanced diaphragm first stages isolate the inner mechanism from the surrounding water. Balanced diaphragm first stages allow air to flow through a seat and pin assembly, which is controlled by a loaded diaphragm. This first stage system also resists changes in performance with changing tank pressures because the seat receives equal interstage pressure from both sides. Balanced diaphragm systems deliver a slightly lower flow than piston regulators, which are only noticeable at deeper depths and/or with dense breathing gases such as air. This is due to the smaller diameter air passageways. Dry Balance Chamber - Cold Water Diving The dry chamber prevents water from entering the balancing chamber and ensures the best performance in cold water. In extremely cold water conditions, the formation of ice crystals around the main spring is thus eliminated. High-Pressure Ports Halcyon regulators feature two high-pressure ports, allowing a submersible pressure gauge, computer hose, or transmitter to be positioned on the right or left side of the diver according to preference and/ or correct transmitter orientation. Intermediate-Pressure Ports The availability of at least four intermediate pressure ports enables the connection of equipment such as an octopus second stage, buoyancy compensator, dry suit hose, or other accessories. HF Ports High Flow ports have a 15% higher flow compared to the standard ports, and thus are especially suited to connect the second stages. Halcyon s H-50D has two HF ports, and the H-75P has five HF ports. DIN vs Yoke Connections Halcyon first stages come standard with DIN tank valve connections, that can be converted for use on a yoke tank valve by using a yoke converter. Do not connect an Aura second stage to the central LP port of the swivel turret in the H-75P first stage. The axial-direct high flow could make your Aura second stage not work properly.
10 Halcyon Second Stage Features Balanced System By using a balanced first stage design, Halcyon is able to use a much lighter spring, decreasing the inhalation resistance and providing a smoother breathing second stage. Diver Adjustable Inhalation Resistance Control Halcyon adjustable second stages have an external control knob acting directly on the spring tension (see Img. 1, point 9 on p. 5). This adjustment allows the diver to adjust the inhalation resistance in order to adapt it to the needs of the dive conditions. Adjusting the control knob (clockwise rotation) causes an increase in inhalation resistance. Adjusting with a counterclockwise rotation reduces the spring tension for lower inhalation effort. Divers may adjust this breathing tension to counteract heavy exertion or conversely the tendency for free flow in certain positions. A higher inhalation resistance does not necessarily imply a lower air consumption, in fact it may even have the opposite effect, due to the higher effort required to trigger the air flow increasing your work of breathing. A.C.V. (Air Control Vane) The Air Control Vane (A.C.V.) directs high-speed air flow over a special vane that creates an area of low pressure inside the second stage housing. This depression pulls the diaphragm inside the housing, maintaining pressure on the valve lever and keeping the valve open without requiring additional effort on the part of the diver. On some Halcyon second stages, the A.C.V. can be adjusted during the dive by changing the position of the flow vane via the knob positioned on the outside of the second stage. On Halcyon second stages not equipped with an external knob, the A.C.V. position is preset to provide high performance while resisting free-flow. This vane can be adjusted by any Halcyon Authorized service technician. Image 5. Second stage Halo Image 6. Second stage Aura 10
11 11 Comparison of Regulator Features The following tables summarize the specific features of Halcyon first and second stages. First Stage H-75P H-50D Technology Piston Air-balanced-flow-through Classic downstream Balanced diaphragm Materials Chrome-plated brass body Cold water Freeze resistant piston Dry chamber Nitrox compatibility Nitrox compatible to 40% from the factory Ports Intermediate-pressure Ports (IP) 5 4 High Flow Ports (HFP) 5 2 High-pressure (HP) Ports 2 2 Swivelling turret with IP Ports Configuration DIN 300-bar (4351-psi) Externally adjustable intermediate pressure Weight DIN 300 (g/oz) 592 / / 22 Air Flow at 200-bar (l/min / SCFM) >8500 / 301 >6500 / 230 Intermediate pressure (bar/psi) / / Second Stage Halo Aura Technology Air-balanced Classic downstream valve Materials Precision-molded carbon fiber & technopolymer housing Nitrox compatible to 40% from the factory Breathing comfort Diver s adjustable inhalation effort Diver s adjustable A.C.V. (Air Control Vane) High comfort orthodontic mouth piece Left and right attachment for extra convenience Weight (g/oz) 158 / / 5.9 Air Flow at 200-bar (l/min / SCFM) Maximum low pressure (bar/psi) 1850 / / / / 203 REGULATOR CARE AND MAINTENANCE Regulators are life-support devices and should be maintained properly. To keep your regulators in top condition, it is important to have a routine of regular care and maintenance. After every dive (salt or fresh water), rinse the regulator with fresh water. This is also important after diving in chlorinated water (such as a pool). It is important to keep water from entering the system while rinsing them. To avoid getting water inside the regulator during post-dive rinsing, consider the following: 1. Ensure that the high-pressure inlet of the first stage regulator is closed with the specially designed protective cap. 2. Verify the anti-set (where applicable) is not engaged. 3. Should water accidentally enter the low-pressure hose, connect the regulator to the cylinder, open the valve, and press the purge button on the second stage until all water has been expelled. 4. Allow your regulator to dry completely, away from heat and direct sunlight, in a well-ventilated, dry place.
12 Regulator Storage Guidelines Prior to storage, engage the anti-set device by slightly depressing and turning the purge button. Only on the Halo second stage (see Image 7). On second stage regulators equipped with an inhalation assistance knob, unscrew the adjustment knob fully. Confirm that the protective cap, on the first stage s high pressure inlet, is in the correct position. Soak the second stage mouthpiece in a disinfecting solution then rinse thoroughly and completely remove the disinfectant before storage. Choose a mild disinfectant to avoid damaging the mouthpiece. Be sure your regulators are completely dry before putting them away. It is best to store regulators in a dry place, away from heat and direct sunlight. Image 7. Anti-set device Repairs and maintenance must be carried out by an Authorized Halcyon Dealer service facility, with the exclusive use of original Halcyon spare parts. Equipment must be serviced by qualified personnel at the prescribed intervals. NITROX Maintenance Maintenance procedures beyond the simple operations described in the preceding paragraph should not be carried out by the user; these should only be conducted by a Halcyon Authorized service technician. A Halcyon authorized technician must verify the correct operation of the regulator every year or every 100 dives, whichever comes first. Conducting an annual service is also mandatory in order to maintain the limited lifetime warranty. Servicing is available through Halcyon Authorized dealers identified by the Authorized Halcyon Dealer sign or by visiting The term nitrox (oxygen-enriched air) defines breathable mixes composed of oxygen and nitrogen and containing oxygen in a percentage higher than 21% (atmospheric air). Higher oxygen concentrations limit the use of these mixes with standard scuba equipment and require the use of materials and procedures that differ from those required by the use of atmospheric air. Use of Nitrox Mixes Outside of the European Community Halcyon regulators are manufactured with materials, assembly procedures, and lubricants that ensure compatibility with gas mixes containing oxygen up to 40%. All Halcyon regulators are distributed with DIN connections. Users are required to follow the same safety procedures that apply to dedicated Nitrox regulators and to comply with the regulations set by each country concerning the use on Nitrox mixes for diving. 12
13 13 If Halcyon regulators have been used with standard compressed air, it will be necessary to perform a new maintenance and cleaning procedure specifically designed for the use of Nitrox mixes and carried out by a Halcyon authorized technician, before using them again with Nitrox. Use of Nitrox Mixes Inside the European Community Within the European Community the use of Nitrox mixes is regulated by norms EN13949 and EN Halcyon has designed and manufactured a special regulator line that complies with the aforementioned regulations. The first and second stage regulators of this line are identified by the marking Nitrox and also marked with special stickers, to allow an immediate identification. These regulators can be used with oxygen-enriched air containing an oxygen concentration higher than 22% and up to 100% (pure oxygen), at a maximum operating pressure of 300 bar (4351 psi). Main Features of Nitrox Dedicated Regulators As required by European Norms, Nitrox first stage regulator connections have been designed and approved to be used exclusively with Nitrox cylinders and cylinder valves, in order to prevent confusion with the corresponding standard-production compressed air regulators. Halcyon Nitrox connections complywith EN (M26x2 connection). In Nitrox first stage regulators, compatibility with high pressure oxygen (higher than 40 bar / 480 psi and up to 300 bar (4351 psi)) is ensured by the choice of special materials used to manufacture seats, O-rings, gaskets and seals used in the high pressure first stage mechanism valves. Components are lubricated with a specific oxygen lubricant. Halcyon Nitrox regulators are assembled in a dedicated area in order to comply with the high cleanliness standards required for oxygen compatibility. Maximum operating depth (MOD) and exposure times to Nitrox (oxygen-enriched air) mixes are dependent upon the oxygen concentration of the mix in use. To prevent severe and potentially lethal injuries, DO NOT dive using Nitrox (oxygen-enriched air) mixes unless you have first obtained adequate training and certification in their use by a recognized certification agency. Do not use silicone grease on silicone components, as this may cause some parts to deform. In addition, do not use silicone grease on components in the high-pressure area of the first stage as this would compromise compatibility with Nitrox mixes.
14 nitrox regulator Use and Maintenance Notes Nitrox regulators must be used only with oxygen-enriched air and only in combination with compressors and cylinders specifically dedicated to the use of Nitrox mixes. Breathable air (21% oxygen), even if compliant with European Norm EN12021, can contain a certain amount of hydrocarbons. These can ignite in the presence of a high concentration of oxygen. Should Nitrox regulators be used with compressed air coming from a compressor lubricated with standard oil, they could be contaminated by flammable residues that would make them dangerous when used again with oxygen-enriched air. In case of such a contamination, before using the regulator again with Nitrox, it will be necessary to disassemble it and perform an oxygen-specific cleaning in compliance with special procedures (for instance: CGA G-4.1 protocol or ASTM G93-88 or other officially approved procedures) carried out by a Halcyon certified technician trained in oxygen cleaning and procedures. 1. During routine maintenance procedures, it is required to use only genuine Halcyon components specifically approved for the use with oxygen (seats, O-rings, and lubricant). 2. After use, rinse thoroughly with fresh water, let dry completely before storing in a dry, clean, cool place. 3. Never use solvents as they might damage rubber and plastic components. 4. Slowly open the cylinder valve in order to minimize the risk of ignition of the higher oxygen content mixes. 5. Components requiring lubrication (O-rings, etc.) must be treated only with suitable products. In any case, never use silicone grease on components used in the high-pressure parts of the regulator, doing so would compromise the compatability with Nitrox mixes. Second stage regulators, pressure gauges, consoles, and other accessories used in combination with Nitrox first stage regulators must also be compatible with the use of Nitrox mixes. WARRANTY Halcyon Manufacturing regulators include a limited lifetime warranty to the original owner. This limited lifetime warranty covers material and manufacturing defects excluding consumable parts such as O-rings, seats, filter, mouthpiece, and low-pressure hose, etc. Abuse, neglect, improper use or improper maintenance, unauthorized repairs, modifications, accidents, fire or other casualty are also not covered under this warranty. This warranty does not extend to equipment used for commercial including rental, governmental or military purposes. All warranty requests must be accompanied by proof of original purchase from an Authorized Halcyon Dealer. Be sure to save your sales receipt, and present it whenever returning your regulator for warranty service. Should your Halcyon regulator prove to be defective for any reason (other than those listed above) it will be repaired or replaced (at Halcyon s discretion) free of charge excluding shipping and handling charges. Some states in the U.S. and certain foreign countries do not allow limitations on the duration of implied warranties, so this may not apply to you. This warranty gives you specific legal rights. You may have rights which vary from state to state and country to country. 14
15 15 It is dangerous for untrained and incertitude persons to use the equipment covered by this warranty. Therefore, use of these products by an untrained person renders any and all warranties null and void. Use of scuba equipment by anyone who is not a certified diver, or receiving training through a recognized certification agency, shall render void all warranties, expressed or implied.
16 Halcyon Dive Systems 1110 S. Main St. High Springs, FL USA HALCYON [email protected]
Regulator Owner's Manual
Regulator Owner's Manual Copyright Notice This owner s manual is copyrighted, all rights reserved. It may not, in whole or in part, be copied, photocopied, reproduced, translated, or reduced to any electronic
Regulator Owner s Manual DOC/0258/ENG ISSUE 1
Regulator Owner s Manual DOC/0258/ENG ISSUE 1 Copyright Notice This owner s manual is copyrighted, all rights reserved. It may not, in whole or in part, be copied, photocopied, reproduced, translated or
2012 Aqua Lung International, Inc. Regulator Owner s Manual, P/N 127861 rev. 02/12
R e g u l a t o r O w n e r Ê s M a n u a l Regulator OwnerÊs Manual Copyright This owner s manual is protected by the law of 11 March 1957 concerning literary and artistic property. It may not, in whole
FJ2. 2 Ton Trolley Floor Jack Assembly & Operating Instructions
FJ2 2 Ton Trolley Floor Jack Assembly & Operating Instructions READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT. This manual provides important information on proper operation & maintenance.
Dive Rite 200 & 300 Bar Isolator Manifold Service Manual
Dive Rite 200 & 300 Bar Isolator Manifold Service Manual Principal Photography and Text by Pete Nawrocky Copyright 2003 Lamartek Inc. D/B/A Dive Rite 0 Warning This manual is only to be used as a guide
Regulator Owner s Manual DOC/0258/US ISSUE 9
Regulator Owner s Manual DOC/0258/ ISSUE 9 1 Copyright Notice This owner s manual is copyrighted, all rights reserved. It may not, in whole or in part, be copied, photocopied, reproduced, translated or
Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.
1.0 IMPORTANT RECEIVING INSTRUCTIONS Visually inspect all components for shipping damage. Shipping Damage is not covered by warranty. If shipping damage is found, notify carrier at once. The carrier is
Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.
1.0 IMPORTANT RECEIVING INSTRUCTIONS Visually inspect all components for shipping damage. Shipping Damage is not covered by warranty. If shipping damage is found, notify carrier at once. The carrier is
DON T FORGET TO REGISTER YOUR SPARE AIR ONLINE AT www.spareair.com
DON T FORGET TO REGISTER YOUR SPARE AIR ONLINE AT www.spareair.com IMPORTANT SAFETY PRECAUTIONS WARNING: Do not use product until you have read and understand instructions and precautions. Submersible
Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL
Propane Conversion Kit Supersedes: 145.25-IOM2 (708) Form 145.25-IOM2 (908) PROPANE CONVERSION KIT INSTALLATION MANUAL "LPKIT " - PROPANE CONVERSION KIT Kits are available for field conversion from natural
NITROUS TRANSFER PUMP INSTRUCTIONS
NITROUS TRANSFER PUMP INSTRUCTIONS SAFETY TIPS Never directly inhale nitrous oxide. When inhaled in large quantities, nitrous oxide can cause respiratory ailments or in extreme cases, death by suffocation.
Recreational Nitrox Diving
Recreational Nitrox Diving Avoiding Medical Problems Equipment Considerations Table of Contents Avoiding Medical Problems...1 Equipment Considerations for Nitrox... 13 Index... 23 Introduction This booklet
el-720 Carbon Dioxide Gas Leak Detector User s Guide
el-720 Carbon Dioxide Gas Leak Detector User s Guide Congratulations on the purchase of the AccuTools el-720 Carbon Dioxide Gas Leak Detector, the most technologically advanced instrument of its kind.
15GAL STEEL OIL DRAIN WITH 110V PUMP
15GAL STEEL OIL DRAIN WITH 110V PUMP OWNER S MANUAL WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety
Back Pack Sprayer. Operator's Manual MODELS MS - 40 MS - 50
Back Pack Sprayer Operator's Manual MODELS MS - 40 MS - 50 WARNING DANGER Read rules for safe operation and all instructions carefully. ECHO provides this Operator's Manual which must be read and understood
PET-10 INSTRUCTION MANUAL PRESSURE TANK
INSTRUCTION MANUAL PRESSURE TANK PET-10 This manual contains IMPORTANT WARNINGS and INSTRUCTIONS. Equipment in this manual is exclusively for painting purposes. Do not use for other purposes. The operator
CARING FOR YOUR WATER HEATER
http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html Water Heater Inspections CARING FOR YOUR WATER HEATER Venting System (Direct Vent Only) The venting system should be inspected
WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!
WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU! Atlanta (Monroe) GA 770-267-3787 [email protected] www.gpmhydraulic.com What You Don t Know About Hydraulic Accumulators Can Kill You TABLE OF CONTENTS
PBX Series Quick Fit Connector Bimetallic Steam Traps
6262100/6 IM-P626-01 ST Issue 6 PBX Series Quick Fit Connector Bimetallic Steam Traps Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Commissioning
THE UNIVERSITY OF MAINE COMPRESSED GAS CYLINDERS FOR SCUBA DIVING
THE UNIVERSITY OF MAINE COMPRESSED GAS CYLINDERS FOR SCUBA DIVING Department: The University of Maine Safety and Environmental Management Department Page i TABLE OF CONTENTS Section Title Page 1.0 Purpose
BETTIS CONVERSION INSTRUCTIONS TO CONVERT HD SERIES ACTUATORS TO HD-M3, HD-SR-M3 HD-M3HW OR HD-SR-M3HW SERIES PNEUMATIC ACTUATORS
BETTIS CONVERSION INSTRUCTIONS TO CONVERT HD SERIES ACTUATORS TO HD-M3, HD-SR-M3 HD-M3HW OR HD-SR-M3HW SERIES PNEUMATIC ACTUATORS PART NUMBER: 132581 REVISION: A RELEASE DATE: 24 March 2000 Page 1 of 10
HYDRAULIC LIFT TABLE CART 2200-LB.
HYDRAULIC LIFT TABLE CART 2200-LB. OWNER S MANUAL WARNING: Read carefully and understand all MACHINE ADJUSTMENT AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other
MODEL G300 BRAKE BLEEDER
MODEL G300 BRAKE BLEEDER Installation, Operation & Repair Parts Information Branick Industries, Inc. 4245 Main Avenue P.O. Box 1937 Fargo, North Dakota 58103 REV060616 P/N: 81-0035G 1 THIS PAGE INTENTIONALLY
SBC90. Abrasive Blast Cabinet Assembly & Operating Instructions
SBC90 Abrasive Blast Cabinet Assembly & Operating Instructions READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. This manual provides important
580-6001 INSTALLATION AND OPERATION INSTRUCTIONS NOT FOR OXYGEN OR OTHER OXIDIZING GASES
ADI 3205-A Certified ISO 9001 580-6001 Micron Filter Assembly INSTALLATION AND OPERATION INSTRUCTIONS NOT FOR OXYGEN OR OTHER OXIDIZING GASES Before Installing or Operating, Read and Comply with These
MODELS 93/693 By CO2 SEMI-AUTOMATIC
O p e r a t i o n M a n u a l MODELS 93/693 By CO2 SEMI-AUTOMATIC.177 cal BB (4.5 mm) STEEL AIRGUN SHOT 12gm CO2 cylinder only WARNING: NOT A TOY. ADULT SUPERVISION REQUIRED. MISUSE OR CARELESS USE MAY
Single- and Two- Stage Regulators
Single- and Two- Stage Regulators English Français Español Safety and Operating Instructions Revision: D Issue Date: May 14, 2008 Form No.: 0056-1625 We appreciate your business! Congratulations on your
SCUBA TECHNICIAN COURSES
SCUBA TECHNICIAN COURSES Scuba Equipment Service Technicians are the industry's unsung heroes. As scuba gear essentially allows divers to breathe underwater, the people providing equipment support in the
Installation Manual DIAPHRAGM WELL TANK
Installation Manual DIAPHRAGM WELL TANK IN-LINE SERIES: 2-5 & 7 GALLON VERTICAL SERIES: 14-20-25-32-36-52-65-86-96-119 GALLON HORIZONTAL SERIES: 7-14 & 20 GALLON NO LEAD NO LEAD: The weighted average of
INSPECTION, MAINTENANCE AND RECHARGE SERVICE MANUAL P/N 16303
WATER MIST HAND PORTABLE FIRE EXTINGUISHERS Model B270 ¾ Gallon Model B272 2 ½ Gallon INSPECTION, MAINTENANCE AND RECHARGE SERVICE MANUAL P/N 6303 All fire extinguishers should be installed, inspected
SALTER AIRE Plus COMPRESSOR Model 8350 / 8352 / 8353. Instruction Manual. Page 1 of 9
SALTER AIRE Plus COMPRESSOR Model 8350 / 8352 / 8353 Instruction Manual Page 1 of 9 TABLE OF CONTENTS Introduction...3 Important Safeguards..3 System Components...5 Setup and Operation...5 Setup...5 Operation....6
This leaflet provides information on
This leaflet provides information on the fire and explosion hazards in the use of oxygen. It is for anyone who uses oxygen gas in cylinders. HSE8(rev2) Hazards from oxygen Oxygen gas in cylinders is used
Cylinder HAZMAT & Fill Station Operations Compliance. PSI/PCI, Inc. William L. (Bill) High & Mark A. Gresham
Cylinder HAZMAT & Fill Station Operations Compliance PSI/PCI, Inc. William L. (Bill) High & Mark A. Gresham Purpose of Hazmat Training Ø Department of Transportation (DOT) Code of Federal Regulations requires
Ceiling Mount Air Handler Manual
www.surna.com 303.993.5271 Ceiling Mount Air Handler Manual Models: CMAH12, CMAH18, CMAH24, CMAH30, CMAH36, CMAH48, CMAH60 Revised: September 2014 Table of Contents Warranty Information 4 Limited Warranty
Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.
1.0 IMPPORTANT RECEIVING INSTRUCTIONS Visually inspect all components for shipping damage. Shipping Damage is not covered by warranty. If shipping damage is found, notify carrier at once. The carrier is
SunMaxx Solar Filling Station Operating Instructions
SunMaxx Solar Filling Operating Instructions Content 1. Declaration of conformity... 2 2. Introduction... 2 3. Transportation and unpacking... 4 4. Mounting and commissioning... 5 5. End of operation...
FASCINATION 700 HVLP TANNING PRO SYSTEM USER MANUAL
FASCINATION 700 HVLP TANNING PRO SYSTEM USER MANUAL Congratulations on choosing the Fascination 700 HVLP Tanning Pro System! Your system includes the following items: 1 Fascination 700 HVLP Tanning Pro
Refrigerant Charging Unit ICOGD. 020AH1000 Operating Manual. FR.8.2.4-09 İ-COLD 12.03.2014 Rev. 00
E Refrigerant Charging Unit ICOGD 020AH1000 Operating Manual FR.8.2.4-09 İ-COLD 12.03.2014 Rev. 00 Contents Technical Specifications... 20 Safety... 21 A/C System... 22 Components... 23 Control Panel...
Take care with oxygen Fire and explosion hazards in the use of oxygen
Fire and explosion hazards in the use of oxygen This leaflet provides information on the fire and explosion hazards in the use of oxygen. It is for anyone who uses oxygen gas in cylinders. Hazards from
MODEL J SERIES CONVERTER
3030 S Susan Street, MODEL J SERIES CONVERTER REPAIR KIT INSTRUCTIONS Important: Any maintenance, service or repair should be performed by trained and experienced service technicians. Proper tools and
Compressed Gas Cylinder Program
Department of Environmental Health & Safety Procedures Compressed Gas Cylinder Program March 2010 Compressed Gas Cylinder Program Page 1 of 8 Table of Contents I. Introduction II. III. IV. Policy Scope
TECHNICAL DATA. Dry 122a. November 12, 2013
Dry 122a 1. PRODUCT DESCRIPTION The Viking is a quick-opening device. When installed with the required external Anti-flood Device, the assembly is designed to increase the operating speed of Viking Model
tire inflator with pressure gauge
tire inflator with pressure gauge Model 95583 Assembly And Operation Instructions Due to continuing improvements, actual product may differ slightly from the product described herein. 3491 Mission Oaks
Compressor Service & Maintenance Manual
Compressor Service & Maintenance Manual C Series COMPRESSOR (D)C1103 (D)C1203 (D)C2106 (D)C2206 (D)C3210 Copyright 2006 DCI. All Rights Reserved. 92311, Rev. C, 08/13 1 C1000 Series Service & Maintenance
Joanna Myers QAS 515 April 01, 2006 The Design of Scuba Diving Regulators & Breathing Resistance
Joanna Marie Myers Professor Mr. Jim Clauson California State University, Dominguez Hills QAS 515 April 01, 2006 The Problem The greatest limiting factor in any underwater exertion is the performance of
System Saver 318 Air Compressor for Mack E-Tech and ASET Engines
Maintenance Manual 31 System Saver 318 Air Compressor for Mack E-Tech and ASET Engines Revised 08-05 NON-THROUGH DRIVE THROUGH DRIVE Service Notes About This Manual This manual provides service and repair
12V Portable Diaphragm Compressor Operating and Maintenance Instructions
12V Portable Diaphragm Compressor Operating and Maintenance Instructions (Part No. DC2) Part No. Serial Number Date Purchased Table of Contents Page Safety Messages...2 Guidelines for Product Use...2 Operation
CG-1171-20 PTFE Diaphragm Liquid Transfer Pump
3800 N. Mill Road Vineland, NJ 08360 Phone: 800.843.1794 Fax: 800.922.4361 CG-1171-20 PTFE Diaphragm Liquid Transfer Pump This is the safety alert symbol. It is used to alert you to potential personal
U S E R M A N U A L. (CGA 870 Connection)
U S E R M A N U A L 1900 Series (CGA 870 Connection) SAVE THESE INSTRUCTIONS CAUTION Federal (USA) law restricts this device to sale by or on the order of a physician. 300 Held Drive Tel: (+001) 610-262-6090
Professional Precharged Hunting Rifle
TRIGGER ADJUSTMENT. The trigger is set at the factory, but some aspects can be adjusted to suit individual preferences. 1. This screw adjusts the weight of second stage trigger pull, to increase the weight
OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS. INTRODUCTION...1 Scope...1 Description...1 Valve Identification...
OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS INTRODUCTION...1 Scope...1 Description...1 Valve Identification...2 1.0 VALVE INSTALLATION...2 2.0 VALVE MAINTENANCE...3 Actuator Disassembly...3
Flushing and Cleaning the A/C System
Flushing and Cleaning the A/C System Once an AC system has been contaminated or has suffered a failure, the most important part of the AC service to restore the cooling performance to the system = FLUSHING
DST & UST FIRST STAGE REGULATOR
TECHNICAL SUPPORT DST & UST FIRST STAGE REGULATOR MAINTENANCE MANUAL FOR AUTHORISED TECHNICIANS Document No. AP5824 Issue 3 9/12/2005 APEKS MARINE EQUIPMENT LTD, NEPTUNE WAY, BLACKBURN, LANCASHIRE. BB1
MP-4V Heavy Duty Riveter / 39048
MP-4V Heavy Duty Riveter / 39048 This newly designed heavy-duty air/hydraulic riveter is ergonomically designed with the professional in mind. The light weight 3.7 lbs. well balanced MP-4V includes a Vacuum
San josé OWNER S MANUAL
San josé OWNER S MANUAL Assembling & operating manual San josé 30 mbar - PORTABLE GAS BARBECUE 1. 2. 3. Improper installation, adjustment, alteration, service or maintenance can injury or property damage.
STORED PRESSURE STAINLESS STEEL
STORED PRESSURE STAINLESS STEEL WATER FIRE EXTINGUISHERS Model 240-2-1/2 Gallon OWNER'S SERVICE MANUAL NO. 05601 INSPECTION, MAINTENANCE AND RECHARGE All fire extinguishers should be installed, inspected
Instructions For SF 6 Refill Kit
S&C Vista Underground Distribution Switchgear UnderCover, Vault-Mounted, and Pad-Mounted Styles Instructions For SF 6 Refill Kit TABLE OF CONTENTS Section Page Section Page INTRODUCTION..................................
INSTRUCTIONS FOR USE SAFETY PRINCIPLES, OPERATION AND MAINTENANCE FOR. HYDRAULIC PUMP type HP 03L, 05L, 07L volume 3 l, 5 l, 7 l
BRANO a.s, 747 41 Hradec nad Moravicí Czech Republic tel.:+420/ 553 632 316, 553 632 303 fax:+420/ 553 632 407, 553 632 151 http://www.brano.eu [email protected] INSTRUCTIONS FOR USE SAFETY PRINCIPLES, OPERATION
ECHM Recommendations for Safety in multiplace medical hyperbaric chambers
ECHM Recommendations for Safety in multiplace medical hyperbaric chambers Coordination and Correspondence : D. MATHIEU, Service d'urgence Respiratoire, de Réanimation Médicale et de Médecine hyperbare
INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX
Fan Coil Replacement Coil Kit EBX & EBXX These instructions must be read and understood completely before attempting installation. These instructions covers the installation of replacement coil kit into
Code of Practice for the Manual Handling of Gas Cylinder and exchange of regulators
Code of Practice for the Manual Handling of Gas Cylinder and exchange of regulators General information The Manual Handling Operations Regulations 1992 (updated 1998) came into force in January 1993. The
1 / 4 IN. FFL x 4 FT. 9 IN. 1 / 2 IN. ACME x 4 FT. 9 IN. Gauge Accuracy +/-2% Set includes Quick Disconnect Valves
Specifications Blue (Low) Gauge 0-120 PSI Blue Hose 1 / 4 IN. FFL x 4 FT. 9 IN. Red (High) Gauge 0-500 PSI Red Hose 1 / 4 IN. FFL x 4 FT. 9 IN. Yellow Hose 1 / 2 IN. ACME x 4 FT. 9 IN. Gauge Accuracy +/-2%
National- Spencer Inc.
9-27-2010 National- Spencer Inc. 19.2V HEAVY DUTY GREASE GUN PRODUCT SPECIFICATION Charger Input Power 110 VAC Battery Output Power 19.2V Battery Capacity 1500 MAH Battery Pack Charge Time 1 Hour Maximum
Installation Operation Maintenance Troubleshooting
Installation Operation Maintenance Troubleshooting Version 3, 2.1, June/09 Apr/09 1416 1402 Table of Contents Important information 2 Weights & Dimensions 3 Operator s Instructions 4 Flow Diagram 5 Purging
THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494
THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494 1. BEFORE YOU BEGIN IMPORTANT INSTRUCTIONS READ AND SAVE FOR THE CONSUMER WARNING: Risk of scalding or other severe injury. Before completing installation,
Cylinder Leak- Down Tester
Cylinder Leak- Down Tester Item 94190 INSTRUCTIONS AND PRECAUTIONS Visit our website at: http://www.harborfreight.com When unpacking, make sure that the product is intact and undamaged. If any parts are
CONGRATULATIONS! TABLE OF CONTENTS. 1 Safety Warnings 2 About Your Wheels 3 Setting Up Your Wheels 7 Care and Cleaning 8 Warranty
WHEEL MANUAL CONGRATULATIONS! Congratulations on your purchase of Oval Concepts Wheels. Developed to perform at a high level, it is important that you follow the operation and maintenance instructions
Oxy-Fuel Gas Welding. Given a functional oxy-fuel gas unit, instruction and demonstration of use, each student will be able to:
I. Competencies Oxy-Fuel Gas Welding Given a functional oxy-fuel gas unit, instruction and demonstration of use, each student will be able to: A. Identify the major parts of the oxy-fuel gas unit. B. Pass
SOLSTICETM International Leisure Products, Inc. 191 Rodeo Drive Edgewood, NY 11717 Tel (631)254-2155
SOLSTICETM International Leisure Products, Inc. 191 Rodeo Drive Edgewood, NY 11717 Tel (631)254-2155 Introduction We thank you for your purchase of our SOLSTICE SPORTSTER 265 & 266 series boat. Please
Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer
Overview READ ENTIRE INSTRUCTIONS BEFORE STARTING INSTALLATION PARTS LIST A. Flush valve B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve
Tech. Services: (800) 477-8326 Fax: (800) 765-8326 Order Entry: (800) 541-1418 Fax: (800) 288-7031 Internet Address: http://www.powerteam.
ORIGINAL INSTRUCTIONS Form No.102842 5 SPX Hydraulic Technologies 5885 11th Street Rockford, IL 61109-3699 USA Tech. Services: (800) 477-8326 Fax: (800) 765-8326 Order Entry: (800) 541-1418 Fax: (800)
HOW MUCH FUEL DOES A GAS STOVE CONSUME AND HOW MUCH DOES IT COST TO OPERATE?
WHAT IS A BTU? The standard energy measurement is the BTU (British Thermal Unit). Each BTU unit is determined by the amount of thermal energy required to raise the temperature of one pound of water by
BPW32 DN15, DN20 and DN25 Balanced Pressure Wafer Steam Trap
1263050/6 IM-P126-07 ST Issue 6 BPW32 DN15, DN20 and DN25 Balanced Pressure Wafer Steam Trap Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation
Water Tec of Tucson Water Systems
Water Tec of Tucson Water Systems Water Filter Owner s Manual Water Tec of Tucson www.water-tec.com 4601 S. 3 RD Avenue Tucson, AZ 85714 (520) 790-1512 Fax (520) 745-0549 1 MAIN COMPONENTS Your water treatment
DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual
DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR Installation and Operation Manual 1 ENGLISH Safety Instructions 2 Features 2-3 Specifications 3 Installation 4-5 Wiring Diagrams 6-7 Warranty 8
NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS BEFORE USE GENERAL SAFETY INSTRUCTIONS: ALWAYS OPERATE THE UNIT IN AN UPRIGHT POSITION AND PLACE
Hydraulic Air Riveter. Operation Manual RC197 RC198. Recommend for mass production line industrial area. Page 1
Hydraulic Air Riveter Recommend for mass production line industrial area Operation Manual RC197 RC198 Page 1 CONTENTS 1 Important Safety Rules 2 Tool Specification 2.1 Nomenclature 2.2 Technical Data 3
OPERATOR S MANUAL 18 VOLT, 1 HOUR CHARGER
OPERATOR S MANUAL 18 VOLT, 1 HOUR CHARGER P110 Your battery charger has been engineered and manufactured to Ryobi s high standard for dependability, ease of operation, and operator safety. When properly
Installation Instructions 4508 4508S
SYMPHONY Spread Lavatory Faucet with Speed Connect Drain Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only on American Standard faucets. Speed Connect
Instruction Manual. Alfa Laval SB Membrane Sample Valve ESE02963-EN1 2015-10. www.sks-online.com www.sks-webshop.com.
Instruction Manual Alfa Laval SB Membrane Sample Valve ESE02963-EN1 2015-10 Original manual Table of contents The information herein is correct at the time of issue but may be subject to change without
Rexroth Hydraulic Pump A10VO Series User Manual
Rexroth Hydraulic Pump A10VO Series User Manual Rexroth Hydraulic pump A10VO Series User Manual Revised 5/1/2009 Page 1 of 12 Functional Purpose This pump is preferred over a fixed displacement (gear)
QuickAir - 5, - 10 Minute Emergency Escape Breathing Apparatus. Operating Manual
QuickAir - 5, - 10 Minute Emergency Escape Breathing Apparatus Operating Manual Table of Contents 1 General... 2 1.1 Purpose... 2 1.2 Description... 2 2 Operation... 3 2.1 Pre-donning Inspection... 3 2.1.1
DiscovR R134a Refrigerant Identifier
Model 16009 DiscovR R134a Refrigerant Identifier Operating Manual Table of Contents Safety Precautions... 1 Description... 4 Operating Instructions.... 5 Fault Codes.... 7 Troubleshooting... 7 Replacement
Hydraulic control unit series 0086-372-01
Technical Product Information No. 1290 EN Hydraulic control unit series 0086-372-01 Contents Page About this Technical Product Information (TPI) 2 The ORTLINGHAUS numbering system 2 About the product 3
Threaded Inline Air Heaters
Threaded Inline Air Heaters FOR SAFETY & LONG HEATER LIFE, CAREFULLY READ THIS MANUAL BEFORE USE. Safety SHOCK HAZARD! Only qualified individuals should install this heater and related controls. Follow
INSTRUCTIONS AND PARTS LIST FOR MODEL 70H & 75H HAND-OPERATED HYDRAULIC PRESS
INSTRUCTIONS AND PARTS LIST FOR MODEL 70H & 75H HAND-OPERATED HYDRAULIC PRESS SETTING UP THE PRESS FOR OPERATION For shipping convenience, the gauge, pump handle, hoist crank, screw nose and base angles
MODEL T200-F18 MODEL T125-F18 Finish Nailers
P MODEL T200-F18 MODEL T125-F18 Finish Nailers IMPORTANT! DO NOT DESTROY It is the customer s responsibility to have all operators and service personnel read and understand this manual. OPERATING MANUAL
Understanding Anesthetic Delivery Systems Dean Knoll, CVT, VTS (Anes.) Anesthesia Technician Supervisor University of Wisconsin Madison, WI May 2003
Understanding Anesthetic Delivery Systems Dean Knoll, CVT, VTS (Anes.) Anesthesia Technician Supervisor University of Wisconsin Madison, WI May 2003 Knowing the functions of the anesthetic delivery system
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102 THANK YOU FOR CHOOSING YOUR NEW DEHUMIDIFIER. BEFORE USING THE UNIT READ THESE INSTRUCTIONS FULLY AND RETAIN THEM FOR FUTURE REFERENCE
ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user
For the user Instructions for use ecomax Wall hung room sealed fan assisted condensing boilers ecomax 63/ E ecomax 68/ E ecomax 6/ E ecomax 635 E ecomax 84/ E ecomax 88/ E ecomax 835 E GB Table of contents
Instruction Manual Differential Pressure Transmitter
DE28 Instruction Manual Differential Pressure Transmitter Table of Contents 1. Safety Instructions 2. Intended Applications 3. Product Description and Functions 4. Installation 5. Commissioning 6. Maintenance
8 ton air/hydraulic long ram jack
8 ton air/hydraulic long ram jack Model 94562 Set up and Operating Instructions Visit our website at: http://www.harborfreight.com Read this material before using this product. Failure to do so can result
accidents which arise due to nonobservance and the safety information herein.
20 GALLON COMPRESSOR Model: 7342 CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials such as wood, paint, metal, concrete, cement, or other masonry. This
Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components
Schematic Throttles to reduce high upstream pressure to constant lower downstream pressure Throttles to maintain minimum upstream pressure PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE
FX TYPHOON 12. Table of Contents
Owner s Manual FX TYPHOON 12 Table of Contents Table of Contents Warranty Specifications General Instructions Operating Instructions Loading the Magazine Trigger Adjustments Care & Maintenance Recommended
PC1131 Electric Air Compressor
Senco Products Inc. 8485 Broadwell Road Cincinnati, Ohio 45244 PC1131 Electric Air Compressor Operating Instructions 2006 by Senco Products, Inc. Warnings for the safe use of this tool are included in
HYDRAULIC TABLE CART 500-LB.
HYDRAULIC TABLE CART 500-LB. OWNER S MANUAL WARNING: Read carefully and understand all MACHINE ADJUSTMENT AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic
Cleaning Instructions for Burner, Pilot Assembly, and Emitter Screen. Series: 150000 200605 LP Gas
Cleaning Instructions for Burner, Pilot Assembly, and Emitter Screen Series: 150000 200605 LP Gas Tools needed Bottle brush Non-abrasive scouring pad Small utility brush Heavy-duty pipe cleaners Air hose
In-Line Filters and Coalescers with Automatic Drains
Instructions/Parts In-Line Filters and Coalescers with Automatic Drains 310611G EN Air Filter with Automatic Drain Part No. 22601, Series B Maintenance To maintain maximum filtering efficiency and to avoid
FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION
FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION Caution! UV-radiation of this device is in the range of UV-A (320-400 nm). Direct exposure to eyes shall therefore be avoided. UV protection glasses shall
