OPTICAL COHERENCE TOMOGRAPHY (OCT) IS AN
|
|
|
- Marilyn Robinson
- 9 years ago
- Views:
Transcription
1 Thickness Profiles of Retinal Layers by Optical Coherence Tomography Image Segmentation AHMET MURAT BAGCI, MAHNAZ SHAHIDI, RASHID ANSARI, MICHAEL BLAIR, NORMAN PAUL BLAIR, AND RUTH ZELKHA PURPOSE: To report an image segmentation algorithm that was developed to provide quantitative thickness measurement of six retinal layers in optical coherence tomography (OCT) images. DESIGN: Prospective cross-sectional study. METHODS: Imaging was performed with time- and spectral-domain OCT instruments in 15 and 10 normal healthy subjects, respectively. A dedicated software algorithm was developed for boundary detection based on a 2-dimensional edge detection scheme, enhancing edges along the retinal depth while suppressing speckle noise. Automated boundary detection and quantitative thickness measurements derived by the algorithm were compared with measurements obtained from boundaries manually marked by three observers. Thickness profiles for six retinal layers were generated in normal subjects. RESULTS: The algorithm identified seven boundaries and measured thickness of six retinal layers: nerve fiber layer, inner plexiform layer and ganglion cell layer, inner nuclear layer, outer plexiform layer, outer nuclear layer and photoreceptor inner segments (ONL PIS), and photoreceptor outer segments (POS). The root mean squared error between the manual and automatic boundary detection ranged between 4 and 9 m. The mean absolute values of differences between automated and manual thickness measurements were between 3 and 4 m, and comparable to interobserver differences. Inner retinal thickness profiles demonstrated minimum thickness at the fovea, corresponding to normal anatomy. The OPL and ONL PIS thickness profiles respectively displayed a minimum and maximum thickness at the fovea. The POS thickness profile was relatively constant along the scan through the fovea. CONCLUSIONS: The application of this image segmentation technique is promising for investigating thickness changes of retinal layers attributable to disease progression and therapeutic intervention. (Am J Ophthalmol 2008;146: by Elsevier Inc. All rights reserved.) Accepted for publication Jun 10, From the Departments of Electrical and Computer Engineering (A.M.B., R.A.); and Ophthalmology and Visual Sciences (M.S., M.B., N.P.B., R.Z.), University of Illinois at Chicago, Chicago, Illinois. Inquiries to Mahnaz Shahidi, Department of Ophthalmology and Visual Sciences, University of Illinois at Chicago, 1855 West Taylor Street, Chicago, IL 60612; [email protected] OPTICAL COHERENCE TOMOGRAPHY (OCT) IS AN imaging modality that provides cross-sectional images of the retina. The commercially available time-domain (TD) OCT instrument provides software for measurement of total retinal thickness, therefore limiting information on the thickness of retinal layers. Thickness measurement of retinal layers is important as it provides useful information for detecting pathologic changes and diagnosing retinal diseases. Recently, various approaches have been described for retinal thickness measurements from OCT images. Ishikawa and associates have described an approach to segment and extract thickness of retinal layers from Stratus and ultra-highresolution OCT images. 1,2 However, thickness measurements of only four layer segments were derived. Koozekanani and associates described a method for extracting the upper and lower retinal boundaries on OCT images with the use of a Markov model. 3 While this algorithm has shown to be robust, it is limited to detection of only two boundaries. Recently, a method based on an extension of the Markov model was reported for analysis of optic nerve head geometry. 4 Determination of retinal nerve fiber layer thickness based on a deformable spline algorithm has also been reported. 5 This algorithm was developed for tracking nerve fiber layer (NFL) in OCT movies and may be inadequate for detecting multiple layers with varying contrast and noise. Several factors reduce the sharpness of retinal layer boundaries in OCT images and prove challenging for continuous edge detection and accurate retinal layer identification. We have developed a new algorithm to automatically detect retinal layer boundaries and measure the thickness of six layers within the retinal tissue. Our method has advantages over previously reported methods because it utilizes a customized filter for edge enhancement and a gray-level mapping technique that overcomes uneven tissue reflectivity and intersubject variations. In this article, we report the application of this method to timeand spectral-domain (SD) OCT images, comparison of automated and manual segmentation, and a normal baseline for thickness of retinal layers. METHODS SUBJECTS: OCT imaging (Stratus time-domain OCT) was performed in one eye of 15 normal subjects, 10 women /08/$ BY ELSEVIER INC. ALL RIGHTS RESERVED. 679 doi: /j.ajo
2 Spectral-domain OCT imaging was performed using an RTVue100 OCT commercial instrument (Optovue, Fremont, California, USA). Thirty-four raster OCT scans (MM5 protocol) were acquired and exported in TIF format. The vertical scan (scan 17) obtained in 10 subjects was analyzed for deriving thickness profiles. Fourteen OCT scans in the foveal and parafoveal areas of one subject were selected for comparing automated and manual boundary detection. The three horizontal scans (scans three, six, and nine of 34) and three vertical scans (scans 14, 17, and 20 of 34) were 640 pixels (2 mm) in depth and 669 pixels (5 mm) in length. The four horizontal scans (scans 23, 25, 26, and 28 of 34) and four vertical scans (scans 29, 31, 32, and 34 of 34) were 640 pixels (2 mm) in depth and 401 pixels (3 mm) in length. The scans had a depth resolution of 3 m/pixel and spatial resolution of 7.5 m/pixel. IMAGE ANALYSIS: A dedicated software program was developed in Matlab (The Mathworks Inc, Natick, Massachusetts, USA) for automated image analysis, without manual processing. The image analysis algorithm 6 segmented the OCT image by the following steps: 1) alignment of A-scans; 2) gray-level mapping; 3) directional filtering; 4) edge detection; and 5) model-based decision making. FIGURE 1. Retinal layer segmentation step of A-scan alignment applied to a typical time-domain optical coherence tomography (TD OCT) image. (Top) Example of a TD OCT image obtained in one of the subjects in the study. (Bottom) OCT image after alignment of A-scans. and five men, six left and nine right eyes. The subjects ages ranged between 42 and 78 years, with an average of years (mean standard deviation [SD]). OCT imaging (RTVue spectral-domain OCT) was performed in one eye of 11 normal subjects, 10 women and one man, six left and five right eyes. The subjects ages ranged between 45 and 75 years, with an average of 56 7 years (mean SD). Three images were obtained in each eye of 10 subjects. The subjects had ophthalmoscopic examination and no abnormalities were identified. IMAGE ACQUISITION: TD OCT imaging was performed using a Stratus OCT commercial instrument (Carl Zeiss Meditec, Dublin, California, USA). Six radial OCT scans, each 6 mm in length, were acquired. Each radial OCT scan was 1024 pixels (2 mm) in depth and 512 pixels (6 mm) in length and thus had a depth resolution of 2 m/pixel and spatial resolution of 12 m/pixel. The vertical (scan one of six) and horizontal (scan four of six) OCT scans were analyzed. The raw grayscale OCT images were exported for analysis. An example of an OCT image is shown in Figure 1. Each cell layer within the retina tissue displays different reflectance properties and produces peaks on a line profile across the retinal depth. Alignment of A-scans. Common reference points in each A-scan were identified using a two-pass edge detection algorithm 6 and A-scans were shifted so that each reference point was at the same level as the neighboring column. At each pass, the images were smoothed using a Gaussian filter, the derivative of the image in the vertical direction (depth) was calculated, single pixel edges were obtained using nonmaximum suppression, and broken edges were eliminated by hysteresis thresholding, similar to Canny edge detection. 7 Gaussian filtering with a larger support provided the two most prominent edges corresponding to the inner limiting membrane (ILM) and retinal pigment epithelium (RPE). The image was aligned according to the RPE boundary, by shifting each A-scan vertically. Because of heavy blurring to suppress noise, these locations were approximate. Therefore, a second pass was performed with a Gaussian filter with a smaller support for more accurate alignment. Only edges that coincided with the first pass were chosen and A-scans were shifted to their final position. The blurring operations were only used to locate the RPE boundary initially, and did not change the pixel intensity values. The image shown in Figure 1, Top was aligned using this algorithm and the output is shown in Figure 1, Bottom. The algorithm then aligns the A-scans according to a finer boundary, namely, the junction between photoreceptor inner and outer segments (IS/OS). Alignment of A-scans was needed for TD OCT images, attributable to eye motion artifacts because of slower image acquisition time, as compared with SD OCT see ( Figure 4, Top row). This alignment step may be eliminated for SD OCT images, since it did not significantly improve images. 680 AMERICAN JOURNAL OF OPHTHALMOLOGY NOVEMBER 2008
3 FIGURE 2. Retinal layer segmentation steps of gray-level mapping and directional filtering applied to a typical TD OCT image. (Top left) Two functions (G 1 and G 2 ) used for gray-level mapping of the image in Figure 1. (Second row, left) Image after gray-level mapping with G 1, depicts boundaries between nerve fiber layer (NFL) and inner plexiform layer and ganglion cell layer (IPL GCL), the junction between photoreceptor inner and outer segments (IS/OS) and retinal pigment epithelium (RPE). (Third row, left) Image after gray-level mapping with G 2, depicts the remaining boundaries. (Top right) Frequency response of a wedge-shaped 2-dimensional directional filter. (Second row, right) Image displayed in second row, left after directional filtering. (Third row, right) Image displayed in third row, left, after directional filtering. The IS/OS interface appears flat, because of the initial alignment step. Gray-Level Mapping. In OCT images, the region between the RPE boundary and ILM contains primarily three stratified brightness levels and six layers. The transitions between these layers produce edges with different strengths. For example, a typical transition from NFL to inner plexiform layer and ganglion cell layer (IPL GCL) represents an approximate change in gray-level value from 1800 to 1100 (12-bit data), whereas a transition from outer plexiform layer (OPL) to outer nuclear layer (ONL) translates to a change in approximate gray-level value from 1200 to 900. The second transition produces a weaker edge. To strengthen the weak edges, an adaptive gray-level mapping using two mapping functions was performed. 6 The parameters that defined the mapping were decided adaptively for each OCT image using the expectation maximization (EM) algorithm. 8 The two mapping functions, G1 and G2, obtained for the image in Figure 1 are plotted in Figure 2, Top right. The boundaries between NFL and IPL GCL, IS/OS interface, and RPE layer were determined with G1(Figure 2, Second row, left), while the remaining boundaries were determined with G2 (Figure 2, Third row, left). The IS/OS interface appears flat, because of the initial alignment step. Directional Filtering. To overcome edge blurring, a 2-dimensional filter with a wedge-shaped pass band was employed. The design of the directional filter banks was based on our previously published method. 9 This filter suppressed the speckle noise that produces high-frequency variances in horizontal direction, while keeping the detail in vertical direction, which contained the boundary information. The filter preserved edges lying within 45 degrees of the horizontal axis, which emphasizes the importance of aligning columns so that boundaries had a slope close to 0 degrees. The frequency response of the filter is shown in Figure 2, Top left. Images following gray-level mapping in Figure 2, Left panels were processed by directional filtering algorithm and displayed in Figure 2, Right panels. Edge Detection. An edge detection kernel based on the first derivative of Gaussian in the vertical direction was used for obtaining candidate contours for boundaries. 6 The edge detection kernel was applied twice. First, the boundaries between each pair of adjacent bright and dark regions, with bright on the anterior, were extracted. In the second pass, boundaries between each pair of adjacent bright and dark regions, with dark on VOL. 146, NO. 5 RETINAL LAYER SEGMENTATION ON OCT IMAGE 681
4 FIGURE 3. Retinal layer segmentation step of edge detection applied to a typical TD OCT image. (Top left) Edge detection following processing steps displayed in Figure 2 with boundary contour overlaid on the original image. Edge detection following processing steps displayed in Figure 2 with boundary contours overlaid on the original image for (Second row, left) bright-to-dark transitions and (Top right) dark-to-bright transitions. (Second row, right) Boundary contours are displayed on the image following edge detection. (Bottom) Boundary lines were connected and the gaps filled according to the model; six retinal layers were segmented and labeled. After RPE boundary detection, the image was aligned again according to the RPE boundary to maintain the curvature of the IS/OS interface. the anterior, were detected. The peak values were marked as edges, using nonmaximum suppression and hysteresis thresholding. 7 At the output of this step, major significant contour segments and their polarities were marked. The output consisted of contour segments with gaps. The contour segments derived by edge detection were overlaid on the original image. Figure 3, Top left displays NFL boundary, and Figure 3, Second row, left and Figure 3, Top right display bright-to-dark transitions and dark-to-bright transitions, respectively. Model-Based Decision Making. The classification and labeling of edges and creation of continuous contours were performed in this step. The marking of ILM and RPE boundaries in the first step was found to be robust. These boundaries were therefore used to serve as reference points. A model that contained the approximate location of each boundary, along with the polarity of the edges that formed the boundary and relative location of boundaries with respect to each other, was used. For any column in the image (along the retinal depth), starting from the top (anterior) we expected to view boundaries between NFL, IPL GCL, inner nuclear layer (INL), OPL, and ONL, which correspond to edges with the polarities ( 1, 1, 1, 1), respectively. The set of contours obtained at the edge detection step that conformed to this particular order were labeled using this model. For a given column in the image, if the polarities of the contours did not match this order, they were not included in the selected contours. This selection was automatic. This method worked well for strong edges, but occasionally (13.3% of TD OCT and 6.6% of SD OCT images) some scattered light on the image was also marked as a boundary pixel. These false positives appeared as discontinuities along the boundary and were removed using a simple median filter. In the final step, the gaps along the boundary attributable to insufficient edge clues were filled. At this point, the model was fine-tuned using edge clues that were already labeled, and the gaps along the boundary were filled in according to the updated model. After RPE boundary detection, the image was aligned again according to the RPE boundary to maintain the curvature of 682 AMERICAN JOURNAL OF OPHTHALMOLOGY NOVEMBER 2008
5 FIGURE 4. Retinal layer segmentation method applied to a typical spectral-domain OCT (SD OCT) image. (Top left) Example of a SD OCT image. (Top right) Image after A-scan alignment. (Second row, left) Image after gray-level mapping depicts boundaries between layers. (Second row, right) Image after edge detection for dark-to-bright transitions with boundary contours overlaid on the original image. (Third row, left) Image after gray-level mapping depicts NFL boundaries. (Third row, right) Image after edge detection for bright-to-dark transitions with boundary contours overlaid on the original image. (Bottom) Boundary lines were connected; six retinal layers were segmented. the IS/OS interface. The connected contours are marked on the image in Figure 3, Bottom, which is the final output of the algorithm. DATA ANALYSIS: On each OCT image, seven boundaries were detected automatically by the segmentation algorithm. The same images were evaluated by three observers (M.B., R.Z., and N.B.) by manually drawing the boundaries. ImageJ software (NIH, Bethesda, Maryland, USA) was used to open the images, draw the boundaries, and then save the images. A Matlab program was written to compare images with automatically and manually drawn boundaries. The average root mean squared error (RMSE) values between the manually and automatically marked boundaries were calculated. Thickness profiles for each of the six retinal layers were calculated by first subtracting edge locations along the vertical direction (retinal depth) and then averaging thickness values along the horizontal direction, at an interval of every 200 m. Intrasubject variability (reproducibility) was determined as the SD of three measurements in each subject, averaged over all subjects. Intersubject variability was determined as the mean SD of thickness measurements across all subjects. RESULTS RETINAL LAYER SEGMENTATION: The algorithm used the fact that the inner and OPLs appeared brighter than TABLE 1. Automated and Manual Boundary Detection From Time-Domain Optical Coherence Tomography Images Boundary RMSE ( m) Mean Standard Deviation 1 ILM RPE ILM inner limiting membrane; RMSE root mean squared error; RPE retinal pigment epithelium. Comparison of boundary detection between three observers (N.B., R.Z., and M.B.) and the automated algorithm. The RMSE was calculated and averaged over 15 time-domain optical coherence tomography images. The RMSE averaged over three observers is listed. the inner and ONLs in the OCT image. In addition, NFL, RPE, and IS/OS appeared brighter than the rest of the layers. Overall, the algorithm identified the following six layers on the retinal image: NFL, IPL GCL, INL, OPL, ONL PIS, and photoreceptor outer segments (POS), as marked on the sample OCT scan shown in Figure 3, Bottom. The POS layer was bounded by IS/OS and RPE VOL. 146, NO. 5 RETINAL LAYER SEGMENTATION ON OCT IMAGE 683
6 TABLE 2. Automated and Manual Boundary Detection From Spectral-Domain Optical Coherence Tomography Images TABLE 3. Comparison of Automated and Manual Thickness Measurements Thickness ( m) Mean Standard Deviation Automated Manual RMSE ( m) Mean Standard Deviation Boundary Layer 1 ILM RPE ILM inner limiting membrane; RMSE root mean squared error; RPE retinal pigment epithelium. Comparison of boundary detection between three observers (N.B., R.Z., and M.B.) and the automated algorithm. The RMSE was calculated and averaged over 14 spectral-domain optical coherence tomography images. The RMSE averaged over three observers is listed. NFL IPL GCL INL OPL ONL PIS POS NFL nerve fiber layer; IPL GCL inner plexiform layer and ganglion cell layer; INL inner nuclear layer; OPL outer plexiform layer; ONL PIS outer nuclear layer and photoreceptor inner segments; POS photoreceptor outer segments. Mean and standard deviation of thickness profiles (averaged profiles from time-domain optical coherence tomography images of 15 normal subjects) for six retinal layers. Manual thickness measurements represent average values of three observers. FIGURE 5. Comparison of automated and manual segmentation methods. Comparison of thickness profiles of inner retinal layers in 15 normal healthy subjects, derived from the automated algorithm (solid line) and manual segmentation; data averaged for three observers (symbols). inner boundaries. The processing steps and layer segmentation for SD OCT images are depicted in Figure 4. AUTOMATED AND MANUAL COMPARISON: Seven boundaries were detected automatically by the segmentation algorithm in 15 TD OCT and 14 SD OCT images. The average RMSE between the manual and automatically marked boundaries on TD OCT images are presented in Table 1. The RMSE for detection of boundaries ranged between 3.5 and 9.9 m (TD OCT). The average RMSE between the manual and automatically marked boundaries on SD OCT images are presented in Table 2. The RMSE for detection of boundaries ranged between 4.3 and 8.8 m (SD OCT). For both the TD and SD OCT images, the least RMSE values were measured for detection of the ILM FIGURE 6. Thickness profiles in normal subjects from TD OCT images. Thickness profiles of inner (Top) and outer (Bottom) retinal layers measured from TD OCT image, averaged over 15 normal healthy subjects. Error bars represent standard error of the mean. and IS/OS interfaces. The interface between the OPL and ONL had the largest RMSE value. Thickness profiles of six retinal layers were derived based on automated and manual segmentation of 15 TD OCT 684 AMERICAN JOURNAL OF OPHTHALMOLOGY NOVEMBER 2008
7 FIGURE 7. Thickness profiles in normal subjects from SD OCT images. Thickness profiles of inner (Top) and outer (Bottom) retinal layers measured from SD OCT image, averaged over 10 normal healthy subjects. Error bars represent standard error of the mean. THICKNESS PROFILES IN NORMAL SUBJECTS: Thickness profiles of six retinal layers measured along the 6-mm TD OCT vertical scan, averaged over 15 subjects, are shown in Figure 6. The thickness profiles of the inner retinal layers (NFL, IPL GCL, INL) demonstrated a minimum thickness at the fovea. The maximum thickness of the NFL was 48 m along the 6-mm scan. The thickness of the IPL GCL ranged between 13 and 102 m. The thickness of the INL ranged between 7 and 40 m. The OPL thickness profile displayed a minimum thickness at the fovea and ranged between 16 and 54 m along the 6-mm scan. The ONL PIS thickness ranged between 55 and 132 m and the profile displayed a maximum thickness at the fovea. The OPL was thicker and the ONL PIS layer was thinner superior to the fovea as compared with a similar location inferior to the fovea. The POS thickness profile was relatively constant along the 6-mm scan through the fovea, ranging between 34 and 45 m. Thickness profiles of six retinal layers measured along the 5-mm SD OCT vertical scan, averaged over 10 subjects, are shown in Figure 7. Thickness profiles obtained from SD OCT images displayed similar characteristics to those observed from analysis of TD OCT images. The mean intrasubject thickness measurement variability of NFL, IPL GCL, INL, OPL, ONL PIS, and POS was 3, 6, 4, 5, 4, and 2 m, respectively. The mean intersubject thickness measurement variability of NFL, IPL GCL, INL, OPL, ONL PIS, and POS was 5, 10, 4, 6, 8, and 4 m, respectively. images (vertical scans). All six retinal layers were identified on each scan acquired in each of the 15 eyes. The thickness profiles derived from the automated algorithm (solid line) and manual segmentation, average data from three observers (symbols), are shown in Figure 5. The automated and manual thickness profiles appeared similar. NFL thickness showed an increase superior and inferior to the fovea, as expected. The IPL GCL demonstrated a foveal depression, corresponding to normal anatomy. The mean absolute values of differences between the automated and manual thickness measurements were calculated. Combining measurements from six layers resulted in differences of m (Auto-M.B.), m (Auto-N.B.), and m (Auto-R.Z.). The interobserver differences for six layers were m (M.B.-N.B.), m (M.B.-R.Z.), and m (N.B.-R.Z.). A comparison of thickness measurements for each layer by automated and manual (average measurements by three observers) segmentation is shown in Table 3. Mean and SD of thickness measurements by automated segmentations closely matched measurements obtained by manual segmentation. The absolute thickness difference ranged between 0 and 5 m. DISCUSSION THE ABILITY TO MEASURE THICKNESS OF RETINAL LAYERS has potential value for early detection of pathologies and disease diagnosis. In this article, a new segmentation algorithm for automated detection of retinal layer boundaries and measurement of thickness of six layers within the retina tissue was presented. The results of automated segmentation corresponded well with normal retinal anatomy and with measurements obtained using manual segmentation by three observers. Thickness profiles for six retinal layers were established in normal healthy subjects at 200- m intervals along a 6-mm vertical distance on the retina. Retinal layer boundary detection by our automated algorithm was similar to manual outlining of the boundaries by human observers. The calculated RMSE was between 3 and 10 m for detection of seven boundaries on both TD and SD OCT images. Thickness profiles derived by the automated algorithm were similar to profiles calculated from manual boundary detection. On average, the difference between automated and manual segmentation was 4.2 m, and almost identical to the difference between manual measurements by three observers ( 4.4 m). Thickness profiles of inner retinal layers (NFL, IPL GCL, INL) displayed a minimum at the center of VOL. 146, NO. 5 RETINAL LAYER SEGMENTATION ON OCT IMAGE 685
8 fovea, corresponding to normal anatomy. At the foveal center, thickness profiles of OPL and ONL PIS displayed a minimum and maximum, respectively. Along the vertical scan, an asymmetry was observed in these layers. The OPL was thicker and the ONL PIS was thinner superior to the fovea as compared with a similar location inferior to the fovea. The thickness asymmetry was observed on original TD and SD OCT vertical scans, even before image processing (Figure 1, Top), but not on horizontal scans. The observed asymmetry in reflectivity superior and inferior to the fovea was more prominent in TD OCT scans. The observed thickness asymmetry may be attributed to image acquisition artifacts or anatomy. Since most histologic studies are based on temporal-nasal sectioning of human retinas, a literature search yielded no reported information with regard to anatomic variations along the superior-inferior axis. Additional studies are needed to investigate the origin of the observed thickness asymmetry. Previously reported edge detection algorithms were implemented on each image column individually to avoid complications attributable to misalignment of A-scans. 3 In contrast, we used the correlation between adjacent A- scans, which increases the effectiveness of edge detection. In previous studies, image noise was reduced by Gaussian filtering 10 and variants of median filtering. 2,3 While these methods are effective in suppressing noise, they also tend to reduce edge sharpness. To overcome edge blurring, we employed a 2-dimensional filter with a wedge-shaped pass band. This filter suppressed the speckle noise that produces high-frequency variances in horizontal direction, while keeping the detail in vertical direction, which contained the boundary information. Additionally, previous studies performed border detection initially on each A-scan individually, which limits the information from adjacent scans. In our algorithm, histogram equalization was performed on each A-scan to overcome uneven tissue reflectivity, which may also cause instability by amplifying the noise. Inhomogeneous retinal pathologies may cause local changes in reflectance from retinal layers, and thereby limit boundary detection. The influence of these changes on our segmentation algorithm and thickness measurements needs further investigation. Future studies are needed to establish the utility of this algorithm for images obtained in patients with retinal pathologies. An important application of this technique is for detection and monitoring of early and uniform changes in thickness of retinal layers. In more advanced disease, the normal stratification of the retinal layers may be lost. The influence of these changes on detection of retinal layer boundaries needs further investigation. In some instances, it may be necessary to measure thickness of combined layers. Since our algorithm determines thickness of six retinal layers, the thickness sum of layers had to be calculated to compare results with previously reported techniques that measure thickness of up to four layers. The inner retina thickness measurements reported previously 10 were m and were consistent with measurements ( m) obtained by our algorithm as sum thickness of NFL IPL GCL INL OPL. The outer retinal thickness measurements reported previously 10 were m, similar to thickness measurements of m derived for ONL PIS by our algorithm. Thickness measurements of NFL and inner retina complex (IRC) were reported to be m and m (reference 2). These values are consistent with thickness measurements of NFL (31 6 m) and IPL GCL INL (98 19 m). However, the previously reported 2 thickness measurement of OPL ( m) based on low-resolution TD images (128 A-scans) are larger than thickness measurements of OPL (32 8 m) in the current study based on high-resolution TD images (512 A-scans). This discrepancy may be attributed to the difference in OCT image resolution. Outer retina complex (ORC) thickness has been reported to be m (reference 2) and m (reference 1), which is lower than the thickness of ONL PIS POS, measured along the 6-mm scan to be in the range of 91 and 177 m ( m) by our algorithm. From histologic studies, 11 POS has been measured to be 20 to 30 m, which is consistent with measurements of 37 4 m (TD OCT) and 35 4 m (SD OCT) in our study. The observed differences in the ORC thickness derived by our algorithm and a previously reported algorithm 2 may be attributable to a dissimilarity in localization of IS/OS interface and RPE. Additionally, in the current study results were obtained from a single OCT image, while thickness was averaged over six radial OCT images and incorporated interpolated point values, in the previous study. In summary, our algorithm has advantages over previously reported methods because it uses a customized filter to enhance edges along the retinal depth while suppressing speckle noise and a gray-level mapping technique to overcome uneven tissue reflectivity and variance across subjects. The application of this technique is promising for investigating thickness changes of retinal layers attributable to disease. THIS STUDY WAS SUPPORTED BY THE DEPARTMENT OF VETERANS AFFAIRS, WASHINGTON, DC, NIH GRANTS EY14275 AND EY01792, Bethesda, Maryland; and an Unrestricted Departmental Grant from Research to Prevent Blindness Inc, New York, New York. The authors indicate no financial conflict of interest. Involved in design and conduct of study (M.S., A.B., R.A.); collection, management, analysis, and interpretation of data (N.B., M.B., R.Z., A.B., R.A., M.S.); and preparation, review, or approval of the manuscript (M.S., N.B., M.B., A.B., R.A.). The study was approved by the University of Illinois at Chicago Institutional Review Board, and proper informed consent was obtained according to the tenets of the Declaration of Helsinki participation in the research and HIPAA compliance was obtained. 686 AMERICAN JOURNAL OF OPHTHALMOLOGY NOVEMBER 2008
9 REFERENCES 1. Chan A, Duker JS, Ishikawa H, Ko TH, Schuman JS, Fujimoto JG. Quantification of photoreceptor layer thickness in normal eyes using optical coherence tomography. Retina 2006;26: Ishikawa H, Stein DM, Wollstein G, Beaton S, Fujimoto JG, Schuman JS. Macular segmentation with optical coherence tomography. Invest Ophthalmol Vis Sci 2005; 46: Koozekanani D, Boyer K, Roberts C. Retinal thickness measurements from optical coherence tomography using a Markov boundary model. IEEE Trans Med Imaging 2001;20: Boyer KL, Herzog A, Roberts C. Automatic recovery of the optic nerve head geometry in optical coherence tomography. IEEE Trans Med Imaging 2006;25: Mujat M, Chan R, Cense B, et al. Retinal nerve fiber layer thickness map determined from optical coherence tomography images. Optics Express 2005;13: Bagci A, Ansari R, Shahidi M. A method for detection of retinal layers by optical coherence tomography image segmentation [conference proceedings]. IEEE/NLM Proc LISSA 2007; Canny J. A computational approach to edge detection. IEEE Trans Pattern Anal Mach Intell 1986;8: Dempster A, Laird N, Rubin D. Maximum likelihood from incomplete data via the EM algorithm. J R Stat Soc 1977; 39: Bagci A, Ansari R, Reynold W. Low-complexity implementation of non-subsampled directional filter banks using polyphase representations and generalized separable processing [conference proceedings]. IEEE Proc EIT 2007: Shahidi M, Wang Z, Zelkha R. Quantitative thickness measurement of retinal layers imaged by optical coherence tomography. Am J Ophthalmol 2005;139: Hoang QV, Linsenmeier RA, Chung CK, Curcio CA. Photoreceptor inner segments in monkey and human retina: mitochondrial density, optics, and regional variation. Vis Neurosci 2002;19: VOL. 146, NO. 5 RETINAL LAYER SEGMENTATION ON OCT IMAGE 687
10 Biosketch Ahmet M. Bagci, MS, received his BS degree in 1999 and MS degree in 2001 in Electrical Engineering from Bilkent University, Ankara, Turkey. Currently, he is a doctoral candidate at the Electrical and Computer Engineering Department at the University of Illinois at Chicago, Chicago, Illinois. Mr Bagci s area of research is signal and image processing, development of algorithms and methods for segmentation of medical images. 687.e1 AMERICAN JOURNAL OF OPHTHALMOLOGY NOVEMBER 2008
Measure of Confidence. Glaucoma Module Premium Edition
Measure of Confidence Glaucoma Module Premium Edition The Changing Face of Glaucoma Practice Literature 1 Leske et al., Arch Ophthalmol 1997; 115:1051-1057 2 Doughty et al., Surv Ophthalmol 2000; 44:367-408
Image Segmentation and Registration
Image Segmentation and Registration Dr. Christine Tanner ([email protected]) Computer Vision Laboratory, ETH Zürich Dr. Verena Kaynig, Machine Learning Laboratory, ETH Zürich Outline Segmentation
Detection and Restoration of Vertical Non-linear Scratches in Digitized Film Sequences
Detection and Restoration of Vertical Non-linear Scratches in Digitized Film Sequences Byoung-moon You 1, Kyung-tack Jung 2, Sang-kook Kim 2, and Doo-sung Hwang 3 1 L&Y Vision Technologies, Inc., Daejeon,
Scatter Plots with Error Bars
Chapter 165 Scatter Plots with Error Bars Introduction The procedure extends the capability of the basic scatter plot by allowing you to plot the variability in Y and X corresponding to each point. Each
Convolution. 1D Formula: 2D Formula: Example on the web: http://www.jhu.edu/~signals/convolve/
Basic Filters (7) Convolution/correlation/Linear filtering Gaussian filters Smoothing and noise reduction First derivatives of Gaussian Second derivative of Gaussian: Laplacian Oriented Gaussian filters
Canny Edge Detection
Canny Edge Detection 09gr820 March 23, 2009 1 Introduction The purpose of edge detection in general is to significantly reduce the amount of data in an image, while preserving the structural properties
Optic Nerve Imaging. Management of Glaucoma
Optic Nerve Imaging in the Diagnosis and Management of Glaucoma Scott D. Smith, MD, MPH Associate Professor of Clinical Ophthalmology Director, Glaucoma Service Columbia University, New York, NY Glaucoma
Diabetic macular edema (DME) is the primary cause of
Retina Fully Software for Retinal Thickness in Eyes With Diabetic Macular Edema From Images Acquired by Cirrus and Spectralis Systems Joo Yong Lee, 1,2 Stephanie J. Chiu, 3 Pratul P. Srinivasan, 3 Joseph
QUALITY TESTING OF WATER PUMP PULLEY USING IMAGE PROCESSING
QUALITY TESTING OF WATER PUMP PULLEY USING IMAGE PROCESSING MRS. A H. TIRMARE 1, MS.R.N.KULKARNI 2, MR. A R. BHOSALE 3 MR. C.S. MORE 4 MR.A.G.NIMBALKAR 5 1, 2 Assistant professor Bharati Vidyapeeth s college
QAV-PET: A Free Software for Quantitative Analysis and Visualization of PET Images
QAV-PET: A Free Software for Quantitative Analysis and Visualization of PET Images Brent Foster, Ulas Bagci, and Daniel J. Mollura 1 Getting Started 1.1 What is QAV-PET used for? Quantitative Analysis
How To Fix Out Of Focus And Blur Images With A Dynamic Template Matching Algorithm
IJSTE - International Journal of Science Technology & Engineering Volume 1 Issue 10 April 2015 ISSN (online): 2349-784X Image Estimation Algorithm for Out of Focus and Blur Images to Retrieve the Barcode
A Novel Method to Improve Resolution of Satellite Images Using DWT and Interpolation
A Novel Method to Improve Resolution of Satellite Images Using DWT and Interpolation S.VENKATA RAMANA ¹, S. NARAYANA REDDY ² M.Tech student, Department of ECE, SVU college of Engineering, Tirupati, 517502,
NEW. CIRRUS HD-OCT 5000/500 Advancing Smart OCT. Imaging Applications: Anterior Segment Glaucoma Retina. International Version
NEW CIRRUS HD-OCT 5000/500 Advancing Smart OCT Imaging Applications: Anterior Segment Glaucoma Retina International Version NEW PanoMap Analysis Wide-field structural damage assessment for glaucoma NEW
2. MATERIALS AND METHODS
Difficulties of T1 brain MRI segmentation techniques M S. Atkins *a, K. Siu a, B. Law a, J. Orchard a, W. Rosenbaum a a School of Computing Science, Simon Fraser University ABSTRACT This paper looks at
Personal Identity Verification (PIV) IMAGE QUALITY SPECIFICATIONS FOR SINGLE FINGER CAPTURE DEVICES
Personal Identity Verification (PIV) IMAGE QUALITY SPECIFICATIONS FOR SINGLE FINGER CAPTURE DEVICES 1.0 SCOPE AND PURPOSE These specifications apply to fingerprint capture devices which scan and capture
OPTICAL COHERENCE TOMOGRAPHY (OCT) IS A
Normative Reference Ranges for the Retinal Nerve Fiber Layer, Macula, and Retinal Layer Thicknesses in Children SUSAN E. YANNI, JINGYUN WANG, CHRISTINA S. CHENG, KELLY I. LOCKE, YUQUAN WEN, DAVID G. BIRCH,
MEASURES OF VARIATION
NORMAL DISTRIBTIONS MEASURES OF VARIATION In statistics, it is important to measure the spread of data. A simple way to measure spread is to find the range. But statisticians want to know if the data are
Morphological segmentation of histology cell images
Morphological segmentation of histology cell images A.Nedzved, S.Ablameyko, I.Pitas Institute of Engineering Cybernetics of the National Academy of Sciences Surganova, 6, 00 Minsk, Belarus E-mail [email protected]
Scanners and How to Use Them
Written by Jonathan Sachs Copyright 1996-1999 Digital Light & Color Introduction A scanner is a device that converts images to a digital file you can use with your computer. There are many different types
How To Understand The Current Of An Optic Nerve Fiber Layer
A Practical Guide for Journal Interpretation of Current of Optical Glaucoma Coherence Practice, Tomography January-April Retinal 2009;3(1):9-13 Nerve Fiber Layer Measurement A Practical Guide for Interpretation
SOCT Copernicus HR Specification
Specification Light Source: SLED Central Wavelength: 850 nm Axial Resolution: 3 µm Transversal Resolution: 12-18 µm Scanning Speed: 52000 A-Scan per second A-Scan Resolution: 1024 points B-Scan Resolution:
Blood Vessel Classification into Arteries and Veins in Retinal Images
Blood Vessel Classification into Arteries and Veins in Retinal Images Claudia Kondermann and Daniel Kondermann a and Michelle Yan b a Interdisciplinary Center for Scientific Computing (IWR), University
The Normative Database for the RTVue. Software version 4.0. Michael J. Sinai, PhD
The Normative Database for the RTVue Software version 4.0 Michael J. Sinai, PhD Glaucoma is a multi-factorial optic neuropathy with characteristic structural changes and subsequent functional impairment.
Lecture 14. Point Spread Function (PSF)
Lecture 14 Point Spread Function (PSF), Modulation Transfer Function (MTF), Signal-to-noise Ratio (SNR), Contrast-to-noise Ratio (CNR), and Receiver Operating Curves (ROC) Point Spread Function (PSF) Recollect
Spectral domain OCT used to view and quantify choroidal vascular congestion in new subretinal fluid following scleral buckling.
Spectral domain OCT used to view and quantify choroidal vascular congestion in new subretinal fluid following scleral buckling. Robert Gizicki MD, Mohamed Haji, Flavio Rezende Retina Service, Hôpital Maisonneuve-Rosemont,
DESCRIPTIVE STATISTICS. The purpose of statistics is to condense raw data to make it easier to answer specific questions; test hypotheses.
DESCRIPTIVE STATISTICS The purpose of statistics is to condense raw data to make it easier to answer specific questions; test hypotheses. DESCRIPTIVE VS. INFERENTIAL STATISTICS Descriptive To organize,
ECE 533 Project Report Ashish Dhawan Aditi R. Ganesan
Handwritten Signature Verification ECE 533 Project Report by Ashish Dhawan Aditi R. Ganesan Contents 1. Abstract 3. 2. Introduction 4. 3. Approach 6. 4. Pre-processing 8. 5. Feature Extraction 9. 6. Verification
Face detection is a process of localizing and extracting the face region from the
Chapter 4 FACE NORMALIZATION 4.1 INTRODUCTION Face detection is a process of localizing and extracting the face region from the background. The detected face varies in rotation, brightness, size, etc.
GE Medical Systems Training in Partnership. Module 8: IQ: Acquisition Time
Module 8: IQ: Acquisition Time IQ : Acquisition Time Objectives...Describe types of data acquisition modes....compute acquisition times for 2D and 3D scans. 2D Acquisitions The 2D mode acquires and reconstructs
Descriptive Statistics
Y520 Robert S Michael Goal: Learn to calculate indicators and construct graphs that summarize and describe a large quantity of values. Using the textbook readings and other resources listed on the web
Drawing a histogram using Excel
Drawing a histogram using Excel STEP 1: Examine the data to decide how many class intervals you need and what the class boundaries should be. (In an assignment you may be told what class boundaries to
Thresholding technique with adaptive window selection for uneven lighting image
Pattern Recognition Letters 26 (2005) 801 808 wwwelseviercom/locate/patrec Thresholding technique with adaptive window selection for uneven lighting image Qingming Huang a, *, Wen Gao a, Wenjian Cai b
Investigation of Color Aliasing of High Spatial Frequencies and Edges for Bayer-Pattern Sensors and Foveon X3 Direct Image Sensors
Investigation of Color Aliasing of High Spatial Frequencies and Edges for Bayer-Pattern Sensors and Foveon X3 Direct Image Sensors Rudolph J. Guttosch Foveon, Inc. Santa Clara, CA Abstract The reproduction
Comparison to other anterior segment imaging devices
found helpful in a number of areas of ophthalmology. However, in the field of anterior segment tumors its usefulness is confined to a subset of tumors that are confined to the iris, hypo pigmented, and
The Visual Cortex 0 http://www.tutis.ca/neuromd/index.htm 20 February 2013
T he Visual Cortex 0 Chapter contents Contents Chapter 2... 0 T he Visual Cortex... 0 Chapter Contents... 1 Introduction... 2 Optic Chiasm... 2 Where do the eye's ganglion cells project to?... 3 To where
Palmprint Recognition. By Sree Rama Murthy kora Praveen Verma Yashwant Kashyap
Palmprint Recognition By Sree Rama Murthy kora Praveen Verma Yashwant Kashyap Palm print Palm Patterns are utilized in many applications: 1. To correlate palm patterns with medical disorders, e.g. genetic
Subjects: Fourteen Princeton undergraduate and graduate students were recruited to
Supplementary Methods Subjects: Fourteen Princeton undergraduate and graduate students were recruited to participate in the study, including 9 females and 5 males. The mean age was 21.4 years, with standard
TEXT-FILLED STACKED AREA GRAPHS Martin Kraus
Martin Kraus Text can add a significant amount of detail and value to an information visualization. In particular, it can integrate more of the data that a visualization is based on, and it can also integrate
Machine Learning for Medical Image Analysis. A. Criminisi & the InnerEye team @ MSRC
Machine Learning for Medical Image Analysis A. Criminisi & the InnerEye team @ MSRC Medical image analysis the goal Automatic, semantic analysis and quantification of what observed in medical scans Brain
Practical Tour of Visual tracking. David Fleet and Allan Jepson January, 2006
Practical Tour of Visual tracking David Fleet and Allan Jepson January, 2006 Designing a Visual Tracker: What is the state? pose and motion (position, velocity, acceleration, ) shape (size, deformation,
Jitter Measurements in Serial Data Signals
Jitter Measurements in Serial Data Signals Michael Schnecker, Product Manager LeCroy Corporation Introduction The increasing speed of serial data transmission systems places greater importance on measuring
Calculation of Minimum Distances. Minimum Distance to Means. Σi i = 1
Minimum Distance to Means Similar to Parallelepiped classifier, but instead of bounding areas, the user supplies spectral class means in n-dimensional space and the algorithm calculates the distance between
COMPARISON OF OBJECT BASED AND PIXEL BASED CLASSIFICATION OF HIGH RESOLUTION SATELLITE IMAGES USING ARTIFICIAL NEURAL NETWORKS
COMPARISON OF OBJECT BASED AND PIXEL BASED CLASSIFICATION OF HIGH RESOLUTION SATELLITE IMAGES USING ARTIFICIAL NEURAL NETWORKS B.K. Mohan and S. N. Ladha Centre for Studies in Resources Engineering IIT
HISTOGRAMS, CUMULATIVE FREQUENCY AND BOX PLOTS
Mathematics Revision Guides Histograms, Cumulative Frequency and Box Plots Page 1 of 25 M.K. HOME TUITION Mathematics Revision Guides Level: GCSE Higher Tier HISTOGRAMS, CUMULATIVE FREQUENCY AND BOX PLOTS
The process components and related data characteristics addressed in this document are:
TM Tech Notes Certainty 3D November 1, 2012 To: General Release From: Ted Knaak Certainty 3D, LLC Re: Structural Wall Monitoring (#1017) rev: A Introduction TopoDOT offers several tools designed specifically
Super-resolution method based on edge feature for high resolution imaging
Science Journal of Circuits, Systems and Signal Processing 2014; 3(6-1): 24-29 Published online December 26, 2014 (http://www.sciencepublishinggroup.com/j/cssp) doi: 10.11648/j.cssp.s.2014030601.14 ISSN:
WE ARE in a time of explosive growth
The Spatial Standard Observer: A new tool for display metrology In the design of displays, beauty is in the eye of the beholder. But until recently, the industry has lacked tools to estimate quality as
What role does the nucleolus have in cell functioning? Glial cells
Nervous System Lab The nervous system of vertebrates can be divided into the central nervous system, which consists of the brain and spinal cord, and the peripheral nervous system, which contains nerves,
High Quality Image Magnification using Cross-Scale Self-Similarity
High Quality Image Magnification using Cross-Scale Self-Similarity André Gooßen 1, Arne Ehlers 1, Thomas Pralow 2, Rolf-Rainer Grigat 1 1 Vision Systems, Hamburg University of Technology, D-21079 Hamburg
Parametric Technology Corporation. Pro/ENGINEER Wildfire 4.0 Tolerance Analysis Extension Powered by CETOL Technology Reference Guide
Parametric Technology Corporation Pro/ENGINEER Wildfire 4.0 Tolerance Analysis Extension Powered by CETOL Technology Reference Guide Copyright 2007 Parametric Technology Corporation. All Rights Reserved.
Multimodal Biometric Recognition Security System
Multimodal Biometric Recognition Security System Anju.M.I, G.Sheeba, G.Sivakami, Monica.J, Savithri.M Department of ECE, New Prince Shri Bhavani College of Engg. & Tech., Chennai, India ABSTRACT: Security
WHITE PAPER. Methods for Measuring Flat Panel Display Defects and Mura as Correlated to Human Visual Perception
Methods for Measuring Flat Panel Display Defects and Mura as Correlated to Human Visual Perception Methods for Measuring Flat Panel Display Defects and Mura as Correlated to Human Visual Perception Abstract
Digital Imaging and Multimedia. Filters. Ahmed Elgammal Dept. of Computer Science Rutgers University
Digital Imaging and Multimedia Filters Ahmed Elgammal Dept. of Computer Science Rutgers University Outlines What are Filters Linear Filters Convolution operation Properties of Linear Filters Application
Fundus Photograph Reading Center
Modified 7-Standard Field Digital Color Fundus Photography (7M-D) 8010 Excelsior Drive, Suite 100, Madison WI 53717 Telephone: (608) 410-0560 Fax: (608) 410-0566 Table of Contents 1. 7M-D Overview... 2
High-accuracy ultrasound target localization for hand-eye calibration between optical tracking systems and three-dimensional ultrasound
High-accuracy ultrasound target localization for hand-eye calibration between optical tracking systems and three-dimensional ultrasound Ralf Bruder 1, Florian Griese 2, Floris Ernst 1, Achim Schweikard
Bildverarbeitung und Mustererkennung Image Processing and Pattern Recognition
Bildverarbeitung und Mustererkennung Image Processing and Pattern Recognition 1. Image Pre-Processing - Pixel Brightness Transformation - Geometric Transformation - Image Denoising 1 1. Image Pre-Processing
An Introduction to Point Pattern Analysis using CrimeStat
Introduction An Introduction to Point Pattern Analysis using CrimeStat Luc Anselin Spatial Analysis Laboratory Department of Agricultural and Consumer Economics University of Illinois, Urbana-Champaign
Comparison of different image compression formats. ECE 533 Project Report Paula Aguilera
Comparison of different image compression formats ECE 533 Project Report Paula Aguilera Introduction: Images are very important documents nowadays; to work with them in some applications they need to be
Tracking Moving Objects In Video Sequences Yiwei Wang, Robert E. Van Dyck, and John F. Doherty Department of Electrical Engineering The Pennsylvania State University University Park, PA16802 Abstract{Object
The Nurse/Technician Role Within the Emerging Ophthalmic Technology - OCTs/B-Scan
The Nurse/Technician Role Within the Emerging Ophthalmic Technology - OCTs/B-Scan Margie V. Wilson, COMT Chief Clinical Supervisor UCSD Shiley Eye Center Thanks, Carol! Unfortunately. I have not financial
Processing the Image or Can you Believe what you see? Light and Color for Nonscientists PHYS 1230
Processing the Image or Can you Believe what you see? Light and Color for Nonscientists PHYS 1230 Optical Illusions http://www.michaelbach.de/ot/mot_mib/index.html Vision We construct images unconsciously
Environmental Remote Sensing GEOG 2021
Environmental Remote Sensing GEOG 2021 Lecture 4 Image classification 2 Purpose categorising data data abstraction / simplification data interpretation mapping for land cover mapping use land cover class
Digital Camera Imaging Evaluation
Digital Camera Imaging Evaluation Presenter/Author J Mazzetta, Electro Optical Industries Coauthors Dennis Caudle, Electro Optical Industries Bob Wageneck, Electro Optical Industries Contact Information
Summarizing and Displaying Categorical Data
Summarizing and Displaying Categorical Data Categorical data can be summarized in a frequency distribution which counts the number of cases, or frequency, that fall into each category, or a relative frequency
EFFECT OF MYOPIC LASIK ON RETINAL NERVE FIBER LAYER THICKNESS- IS IT SAFE OR UNSAFE?
24. Glaucoma: Imaging EFFECT OF MYOPIC LASIK ON RETINAL NERVE FIBER LAYER THICKNESS- IS IT SAFE OR UNSAFE? Chief Author: Dr. Amit porwal 1 Co-Authors: Dr. Kavita Porwal 2, Dr. Puja Rai 1 1. Choithram Netralaya,
ALLEN Mouse Brain Atlas
TECHNICAL WHITE PAPER: QUALITY CONTROL STANDARDS FOR HIGH-THROUGHPUT RNA IN SITU HYBRIDIZATION DATA GENERATION Consistent data quality and internal reproducibility are critical concerns for high-throughput
GelAnalyzer 2010 User s manual. Contents
GelAnalyzer 2010 User s manual Contents 1. Starting GelAnalyzer... 2 2. The main window... 2 3. Create a new analysis... 2 4. The image window... 3 5. Lanes... 3 5.1 Detect lanes automatically... 3 5.2
Pie Charts. proportion of ice-cream flavors sold annually by a given brand. AMS-5: Statistics. Cherry. Cherry. Blueberry. Blueberry. Apple.
Graphical Representations of Data, Mean, Median and Standard Deviation In this class we will consider graphical representations of the distribution of a set of data. The goal is to identify the range of
1) Write the following as an algebraic expression using x as the variable: Triple a number subtracted from the number
1) Write the following as an algebraic expression using x as the variable: Triple a number subtracted from the number A. 3(x - x) B. x 3 x C. 3x - x D. x - 3x 2) Write the following as an algebraic expression
A software tool for Quality Assurance of Computed / Digital Radiography (CR/DR) systems
A software tool for Quality Assurance of Computed / Digital Radiography (CR/DR) systems Nikunj Desai a and Daniel J Valentino a,b a icr Company Inc, 2580 West 237th Street, Torrance, CA 90505, USA b Department
Visual Structure Analysis of Flow Charts in Patent Images
Visual Structure Analysis of Flow Charts in Patent Images Roland Mörzinger, René Schuster, András Horti, and Georg Thallinger JOANNEUM RESEARCH Forschungsgesellschaft mbh DIGITAL - Institute for Information
Digital image processing
746A27 Remote Sensing and GIS Lecture 4 Digital image processing Chandan Roy Guest Lecturer Department of Computer and Information Science Linköping University Digital Image Processing Most of the common
Diagrams and Graphs of Statistical Data
Diagrams and Graphs of Statistical Data One of the most effective and interesting alternative way in which a statistical data may be presented is through diagrams and graphs. There are several ways in
SECTION 2-1: OVERVIEW SECTION 2-2: FREQUENCY DISTRIBUTIONS
SECTION 2-1: OVERVIEW Chapter 2 Describing, Exploring and Comparing Data 19 In this chapter, we will use the capabilities of Excel to help us look more carefully at sets of data. We can do this by re-organizing
Retinal Imaging Biomarkers for Early Diagnosis of Alzheimer s Disease
Retinal Imaging Biomarkers for Early Diagnosis of Alzheimer s Disease Eleonora (Nora) Lad, MD, PhD Assistant Professor of Ophthalmology, Vitreoretinal diseases Duke Center for Macular Diseases Duke University
The Limits of Human Vision
The Limits of Human Vision Michael F. Deering Sun Microsystems ABSTRACT A model of the perception s of the human visual system is presented, resulting in an estimate of approximately 15 million variable
Modelling, Extraction and Description of Intrinsic Cues of High Resolution Satellite Images: Independent Component Analysis based approaches
Modelling, Extraction and Description of Intrinsic Cues of High Resolution Satellite Images: Independent Component Analysis based approaches PhD Thesis by Payam Birjandi Director: Prof. Mihai Datcu Problematic
Microsoft Excel 2010 Charts and Graphs
Microsoft Excel 2010 Charts and Graphs Email: [email protected] Web Page: http://training.health.ufl.edu Microsoft Excel 2010: Charts and Graphs 2.0 hours Topics include data groupings; creating
GeoGebra. 10 lessons. Gerrit Stols
GeoGebra in 10 lessons Gerrit Stols Acknowledgements GeoGebra is dynamic mathematics open source (free) software for learning and teaching mathematics in schools. It was developed by Markus Hohenwarter
Medical Image Processing on the GPU. Past, Present and Future. Anders Eklund, PhD Virginia Tech Carilion Research Institute [email protected].
Medical Image Processing on the GPU Past, Present and Future Anders Eklund, PhD Virginia Tech Carilion Research Institute [email protected] Outline Motivation why do we need GPUs? Past - how was GPU programming
Norbert Schuff Professor of Radiology VA Medical Center and UCSF [email protected]
Norbert Schuff Professor of Radiology Medical Center and UCSF [email protected] Medical Imaging Informatics 2012, N.Schuff Course # 170.03 Slide 1/67 Overview Definitions Role of Segmentation Segmentation
Improvement and storage of conventional mammography images using techniques of digital image processing
BJRS BRAZILIAN JOURNAL OF RADIATION SCIENCES 03-1A (2015) 01-13 Improvement and storage of conventional mammography images using techniques of digital image processing M. M. A. Silva a ; J. W. Vieira b,c
A HYBRID APPROACH FOR AUTOMATED AREA AGGREGATION
A HYBRID APPROACH FOR AUTOMATED AREA AGGREGATION Zeshen Wang ESRI 380 NewYork Street Redlands CA 92373 [email protected] ABSTRACT Automated area aggregation, which is widely needed for mapping both natural
Locating and Decoding EAN-13 Barcodes from Images Captured by Digital Cameras
Locating and Decoding EAN-13 Barcodes from Images Captured by Digital Cameras W3A.5 Douglas Chai and Florian Hock Visual Information Processing Research Group School of Engineering and Mathematics Edith
Mean-Shift Tracking with Random Sampling
1 Mean-Shift Tracking with Random Sampling Alex Po Leung, Shaogang Gong Department of Computer Science Queen Mary, University of London, London, E1 4NS Abstract In this work, boosting the efficiency of
IN current film media, the increase in areal density has
IEEE TRANSACTIONS ON MAGNETICS, VOL. 44, NO. 1, JANUARY 2008 193 A New Read Channel Model for Patterned Media Storage Seyhan Karakulak, Paul H. Siegel, Fellow, IEEE, Jack K. Wolf, Life Fellow, IEEE, and
Spectral Line II. G ij (t) are calibrated as in chapter 5. To calibrated B ij (ν), observe a bright source that is known to be spectrally flat
Spectral Line II: Calibration and Analysis 2 Spectral Line II John Hibbard Bandpass Calibration Flagging Continuum Subtraction Imaging Visualization Analysis Reference: Michael Rupen, Chapter 11 Synthesis
Edge tracking for motion segmentation and depth ordering
Edge tracking for motion segmentation and depth ordering P. Smith, T. Drummond and R. Cipolla Department of Engineering University of Cambridge Cambridge CB2 1PZ,UK {pas1001 twd20 cipolla}@eng.cam.ac.uk
Correction of motion artifacts and scanning beam distortions in 3D ophthalmic optical coherence tomography imaging
Correction of motion artifacts and scanning beam distortions in 3D ophthalmic optical coherence tomography imaging Robert J. Zawadzki* a, Alfred R. Fuller b, Stacey S. Choi a, David F. Wiley b,c, Bernd
Notable near-global DEMs include
Visualisation Developing a very high resolution DEM of South Africa by Adriaan van Niekerk, Stellenbosch University DEMs are used in many applications, including hydrology [1, 2], terrain analysis [3],
Computed Tomography Resolution Enhancement by Integrating High-Resolution 2D X-Ray Images into the CT reconstruction
Digital Industrial Radiology and Computed Tomography (DIR 2015) 22-25 June 2015, Belgium, Ghent - www.ndt.net/app.dir2015 More Info at Open Access Database www.ndt.net/?id=18046 Computed Tomography Resolution
Evaluating System Suitability CE, GC, LC and A/D ChemStation Revisions: A.03.0x- A.08.0x
CE, GC, LC and A/D ChemStation Revisions: A.03.0x- A.08.0x This document is believed to be accurate and up-to-date. However, Agilent Technologies, Inc. cannot assume responsibility for the use of this
Hydrogeological Data Visualization
Conference of Junior Researchers in Civil Engineering 209 Hydrogeological Data Visualization Boglárka Sárközi BME Department of Photogrammetry and Geoinformatics, e-mail: [email protected] Abstract
CR-2 AF and CR-2 PLUS AF Non-Mydriatic cameras. Designed for the highest possible image quality. See the smallest details, don t miss pathology.
CR-2 AF and CR-2 PLUS AF Non-Mydriatic cameras Designed for the highest possible image quality. See the smallest details, don t miss pathology. CR-2 AF Extremely compact and lightweight (just 15 kg) camera:
Age- Related Macular Degeneration
Age- Related Macular Degeneration Age-Related Macular Degeneration (AMD) is the leading cause of blindness in the United States. It is caused by damage to a localized area of the central retina called
