Monitoring of Cerebral Blood Flow. Transcranial Doppler Laser Doppler Flowmetry Thermal dilution method (Hemedex)
|
|
|
- Ezra Jackson
- 9 years ago
- Views:
Transcription
1 Monitoring of Cerebral Blood Flow Transcranial Doppler Laser Doppler Flowmetry Thermal dilution method (Hemedex)
2 Ultrasound in Tissue Some Facts: blood cell tissue probe ultrasound travels at a constant speed of 1540m/s in tissue. ultrasound is reflected at the boundary of two media. ultrasound is backscattered n heterogenous tissues. the higher the ultrasound fequency the higher the attenuation and the hallower the penetration depth.
3 Doppler Principle in Sonography a ultrasound signal is used to insonate the vessels, e.g. 2MHz. blood cells tissue 2MHz 2.005MHz= 2MHz+5kHz probe this signal is reflected and backscattered from moving objects (e.g. blood cells) with a positive or negative frequency shift. the frequency shift is also called Doppler shift or Doppler signal. the faster the blood cells are moving the higher Doppler shift.
4 Doppler Formula Doppler Frequency Shift: f d = Velocity: 2*f t *v*cos ß v 0 f d : Doppler frequency shift f t : ultrasound frequency, e.g. 2MHz v: velocity of the moving blood cells v 0 : velocity of ultrasound in tissue (1540m/s) ß: angle of insonation v = simplified: v = f d * v 0 *f d 2*f t *cos ß 1540m/s 2*2MHz*1 The Doppler frequency shift is the only variable in the above shown formula, therefore we have a linear relationship between blood flow velocity and Doppler frequency shift.
5 Thanks to Dr.DJ Kim
6 Doppler System Transducer Electronics Signal Processing Computer Audio Doppler Signal: Doppler signal time signal audio output difficult to analize FFT Fast Fourier Transform Spectral Display: frequencies and velocities spectral display parameters like envelope, PI easier to analize
7 Spectral Display, Indices Envelope (maximum frequency follower) systolic peak vlocity Mean Velocity enddiastolic velocity Spectra
8 Pulsatility Indices Vsys Vmean Gosling s Pulsatility Index PI = Vsys-Vdia Vmean Vdia Pourcelot s Resistance Index RI = Vsys-Vdia Vsys
9 MCA Bifurcation
10 Investigation of ICA
11 Cerebrovascular Laboratory Thanks to Dr.P.Smielwski
12 Testing of Cerebrovascular Reactivity using TCD Acetazolamide test Inhibitor of carbonic anhydrase in red cells. Intravenous administration of 1 g of acetazolamide causes normally 30%-60% increase in CBF. Advantages: does not change ABP, does not require patient s co-operation. Disadvantages: 2-h duration of action. Thanks to Dr.P.Smielwski
13 Acetazolamide test DFV FVbas DFV Reactivity = FVbas Normal values : % (Sullivan et al., 1987) Thanks to Dr.P.Smielwski
14 CO 2 reactivity test Change in CO2 concentration of the inspired gas Breath holding Manipulation of ventilation in sedated patients Thanks to Dr.P.Smielwski
15 CO 2 Reactivity Methods of assessment Change in FV to change in PaCO 2 ratio DCO 2 Reactivity = DFV DCO 2 1 FVbas Normal values : %/kpa DFV FVbas Thanks to Dr.P.Smielwski
16 Thanks to Dr.P.Smielwski CO 2 Reactivity Methods of assessment Linear regression Reactivity = 25.1 %/kpa Reactivity = Slope of regr. Reactivity = 7.6 %/kpa Normal values : %/kpa
17 Transient Hyperaemic Response Test Definition Carotid compression Transient hyperaemic response ratio THRR FVS FVS hyperaemia baseline compression release Thanks to Dr.P.Smielwski
18 Transient Hyperaemic Response Test THRT Positive Intact Autoregulation THRT Negative Impaired autoregulation THRR = 1.45 THRR = 0.95 Thanks to Dr.P.Smielwski
19 Transient Hyperaemic Response Test Test repeated at different CO 2 levels Normocapnia Hypercapnia Hypocapnia THRR 1.18 THRR 1.19 THRR 1.05 THRR 1.04 THRR 1.37 THRR sec. Thanks to Dr.P.Smielwski
20 Brain monitoring on NCCU
21 Continuous monitoring of CBF: Hyperaemic waves of ICP
22 Refractory intracranial hypertension:
23 Multimodal CBF monitoring
24 Laser Doppler Flowmetry Figure 1 Basic operating principles of laser Doppler flowmetry. A laser beam is directed to an area of tissue. Upon contact with red blood cells in the target tissue, light waves are reflected and scattered, resulting in broadening of the light wave frequency, which is detected and received by a photodector.
25 Clinical monitoring of rcbf using LDF
26 Experimental monitoring Thanks to Dr. K.Brady
27 LDF flux during plateau elevation of ICP ABP mmhg ICP mmhg LDF
28 Pulse wave of LDF flux ABP mmhg ICP mmhg LDF LDF
29 LDF during refractory elevation of ICP ABP mmhg LDF ICP mmhg LDF ICP mmhg
30 Hemedex- rcbf measurement using thermal dilution method
31 Thanks to Dr A.Oshorov Changes in Hemedex CBF related to changes in EtCO2 CBF ml/min/100g ICP mmhg PaCO2 mmhg
32 Slow waves in Hemedex CBF and ICP CBF ml/min/100g ICP mmhg Cross-spectrum Coherence ICP-CBF
33 Head injury- CBF fluctuates independently on CPP ABP mmhg ICP mmhg CPP mmhg CBF ml/min/100g
34 But not always: example of homogenous Lassen s curve; 3 days monitoring, TBI Thanks to Dr. N. De Riva Solla
35 Calibration gaps- main source of variation in measured CBF ABP mmhg ICP mmhg CPP mmhg CBF ml/min/100g
36 Typical Thanks to Dr. N. Der Riva Solla
37 Message to take home TCD- non-invasive, indirect and difficult in continuous monitoring TCD- information included in mean velocity and waveform TCD- very good dynamical response LDF- invasive, indirect LDF- rarely used in clinical practice LDF- biological zero Hemedex- invasive, direct Hemedex- lot of fluctuations which seem to be artificial
20. Cerebral Compartmental Compliances
20. Cerebral Compartmental Compliances CBF a (t) Cerebral arterial inflow Cerebral arterial blood volume (C a BV) mean CBF a 0 CBF v (t) Cerebral venous outflow CBV(t) mean CBV + - t t ΔCBV (CBF (t) CBF
Doppler. Doppler. Doppler shift. Doppler Frequency. Doppler shift. Doppler shift. Chapter 19
Doppler Doppler Chapter 19 A moving train with a trumpet player holding the same tone for a very long time travels from your left to your right. The tone changes relative the motion of you (receiver) and
perfusion pressure: Definitions. Implication on management protocols. What happens when CPP is too low, and when it is too high? Non-invasive CPP?
7. Cerebral perfusion pressure: Definitions. Implication on management protocols. What happens when CPP is too low, and when it is too high? Non-invasive CPP? Definitions of CPP Thanks to Dr. E. Schmidt
Pressure reactivity: Relationship between ICP and arterial blood pressure (ABP). Pressure-reactivity index, computational methods. Clinical examples.
Pressure reactivity: Relationship between ICP and arterial blood pressure (ABP). Pressure-reactivity index, computational methods. Clinical examples. Optimization of cerebral perfusion pressure: Relationship
TCD in Intensive Care
TCD in Intensive Care Background: Transcranial Doppler (TCD) ultrasonography is a technique that uses a hand-held Doppler transducer (placed on the surface of the cranial skin) to measure the velocity
Statistical Analysis of Arterial Blood Pressure (ABP), Central Venous. Pressure (CVP), and Intracranial Pressure (ICP)
Statistical Analysis of Arterial Blood Pressure (ABP), Central Venous Pressure (CVP), and Intracranial Pressure (ICP) Heechang Kim, Member, IEEE Portland State University E-mail: [email protected] This
Vascular Laboratory Fundamentals. Robert Mitchell MD, RPVI Duke University Medical Center 5/2/08
Vascular Laboratory Fundamentals Robert Mitchell MD, RPVI Duke University Medical Center 5/2/08 Goals of Lecture Understand basic ultrasound principles Understand normal and abnormal arterial hemodynamics
Clinical Research Software for Intensive Care Monitoring
The past, the present and the future Clinical Research Software for Intensive Care Monitoring Dr Peter Smielewski Dept of Clinical Neurosciences University of Cambridge Disclosure ICM+ software is licensed
10. Monitoring of pressure-volume compensation- VPR and RAP
10. Monitoring of pressure-volume compensation- VPR and RAP Various shapes of Pressure-Volume curves J.Neurosurg 1975, Vol 42 Volume pressure response is proportional to mean ICP but not always Avezaat
Hunting Bats. Diagnostic Ultrasound. Ultrasound Real-time modality
Diagnostik Ultrasound Basic physics, image reconstruction and signal processing Per Åke Olofsson Dpt of Biomedical Engineering, Malmö University Hospital, Sweden Ultrasound Real-time modality 17-WEEK FETAL
13. Volume-pressure infusion tests: Typical patterns of infusion studies in different forms of CSF circulatory disorders.
13. Volume-pressure infusion tests: Typical patterns of infusion studies in different forms of CSF circulatory disorders. Hydrocephalus is far more complex than disorder of CSF circulation CSF circulation
Cerebral blood flow (CBF) is dependent on a number of factors that can broadly be divided into:
Cerebral Blood Flow and Intracranial Pressure Dr Lisa Hill, SpR Anaesthesia, Royal Oldham Hospital, UK. Email [email protected] Dr Carl Gwinnutt, Consultant Neuroanaesthetist, Hope Hospital, UK. The
Doppler Ultrasound in the Management of Fetal Growth Restriction Chukwuma I. Onyeije, M.D. Atlanta Perinatal Associates
Doppler Ultrasound in the Management of Fetal Growth Restriction Chukwuma I. Onyeije, M.D. Atlanta Perinatal Associates 1 For your convenience a copy of this lecture is available for review and download
Biomedical Optics Theory
Introduction Biomedical Optics Theory Diffuse reflectance spectroscopy (DRS) and Laser Doppler Flowmetry (LDF) are booth optical techniques that can quantify a number of microcirculatory parameters. Prof
Ultrasound Technologies. PD1v. vascular pocket doppler. Operating Instructions
Ultrasound Technologies PD1v vascular pocket doppler Operating Instructions Before using your Pocket Doppler for the first time, please read these operating instructions carefully. 1 INTRODUCTION The UltraTec
Applications of Doppler Ultrasound in Fetal Growth Assessment. David Cole
Applications of Doppler Ultrasound in Fetal Growth Assessment David Cole Aims The aim of this presentation is to consider the use of Doppler ultrasound to investigate and monitor those pregnancies at risk
Functional Data Analysis of MALDI TOF Protein Spectra
Functional Data Analysis of MALDI TOF Protein Spectra Dean Billheimer [email protected]. Department of Biostatistics Vanderbilt University Vanderbilt Ingram Cancer Center FDA for MALDI TOF
Principles of Medical Ultrasound. Pai-Chi Li Department of Electrical Engineering National Taiwan University
Principles of Medical Ultrasound Pai-Chi Li Department of Electrical Engineering National Taiwan University What is Medical Ultrasound? Prevention: actions taken to avoid diseases. Diagnosis: the process
THERAPY INTENSITY LEVEL
THERAPY INTENSITY LEVEL TILBasic = TIL Basic. CDE Variable TILBasic = TIL Basic; Global summary measure of Therapy Intensity Level for control of Intracranial Pressure (ICP).. CDE Definition This summary
Spectral Doppler Sonography: Waveform Analysis and Hemodynamic Interpretation
Chapter 4 Spectral Doppler Sonography: Waveform Analysis and Hemodynamic Interpretation Dev Maulik The spectral Doppler power waveform contains an immense amount of hemodynamic information from the sampled
Laerdal Patient Monitor Help Page 1 June 14, 2012, Rev E
Laerdal Patient Monitor Help Page 1 Using the Laerdal Patient Monitor The Laerdal Patient Monitor software is used to simulate a typical Patient Monitor found in hospitals and ambulances. It is made available
Extracranial Cerebrovascular Duplex Ultrasound Evaluation
VASCULAR TECHNOLOGY PROFESSIONAL PERFORMANCE GUIDELINES Extracranial Cerebrovascular Duplex Ultrasound Evaluation This Guideline was prepared by the Professional Guidelines Subcommittee of the Society
Laminar and Turbulent flow. Flow Sensors. Reynolds Number. Thermal flow Sensor. Flow and Flow rate. R = Mass Flow controllers
Flow and Flow rate. Laminar and Turbulent flow Laminar flow: smooth, orderly and regular Mechanical sensors have inertia, which can integrate out small variations due to turbulence Turbulent flow: chaotic
VFI Technology to Change the Way You Work
Technology to Change the Way You Work Vascular Ultrasound Made Easier Vector Flow Imaging VFI VFI is a ground-breaking technology that can revolutionize the workflow for many Doppler ultrasound applications.
(Refer Slide Time 1:13 min)
Mechanical Measurements and Metrology Prof. S. P. Venkateshan Department of Mechanical Engineering Indian Institute of Technology, Madras Module - 1 Lecture - 1 Introduction to the Study of Mechanical
BIOMEDICAL ULTRASOUND
BIOMEDICAL ULTRASOUND Goals: To become familiar with: Ultrasound wave Wave propagation and Scattering Mechanisms of Tissue Damage Biomedical Ultrasound Transducers Biomedical Ultrasound Imaging Ultrasonic
ANALYZER BASICS WHAT IS AN FFT SPECTRUM ANALYZER? 2-1
WHAT IS AN FFT SPECTRUM ANALYZER? ANALYZER BASICS The SR760 FFT Spectrum Analyzer takes a time varying input signal, like you would see on an oscilloscope trace, and computes its frequency spectrum. Fourier's
High-Concentration Submicron Particle Size Distribution by Dynamic Light Scattering
High-Concentration Submicron Particle Size Distribution by Dynamic Light Scattering Power spectrum development with heterodyne technology advances biotechnology and nanotechnology measurements. M. N. Trainer
STATISTICAL ANALYSIS OF ULTRASOUND ECHO FOR SKIN LESIONS CLASSIFICATION HANNA PIOTRZKOWSKA, JERZY LITNIEWSKI, ELŻBIETA SZYMAŃSKA *, ANDRZEJ NOWICKI
STATISTICAL ANALYSIS OF ULTRASOUND ECHO FOR SKIN LESIONS CLASSIFICATION HANNA PIOTRZKOWSKA, JERZY LITNIEWSKI, ELŻBIETA SZYMAŃSKA *, ANDRZEJ NOWICKI Institute of Fundamental Technological Research, Department
Functional neuroimaging. Imaging brain function in real time (not just the structure of the brain).
Functional neuroimaging Imaging brain function in real time (not just the structure of the brain). The brain is bloody & electric Blood increase in neuronal activity increase in metabolic demand for glucose
IAC Standards and Guidelines for Vascular Testing Accreditation
IAC Standards and Guidelines for Vascular Testing Accreditation 2015 Intersocietal Accreditation Commission. All Rights Reserved. Table of Contents All entries in Table of Contents are linked to the corresponding
TISSUE MIMICKING GEL QUALITY LE PHANTOM SERIES DESIGN. performance the ultrasound labs ofand. icking material has the same attenuation mim-
QUALITY Tissue Benefits Mimicking of s RMI recognized RMI as the ultrasound standard phantoms for quality are performance the ultrasound labs ofand hospitals, manufacturers. clinics Sophisticated and ultrasound
Physiological Basis of the BOLD Signal. Kerstin Preuschoff Social and Neural systems Lab University of Zurich
Physiological Basis of the BOLD Signal Kerstin Preuschoff Social and Neural systems Lab University of Zurich Source: Arthurs & Boniface, 2002 From Stimulus to Bold Overview Physics of BOLD signal - Magnetic
Testing thermo-acoustic sound generation in water with proton and laser beams
International ARENA Workshop DESY, Zeuthen 17th 19th of May 25 Testing thermo-acoustic sound generation in water with proton and laser beams Kay Graf Universität Erlangen-Nürnberg Physikalisches Institut
Micro-Optical Sensor Use in Boundary Layer Flows with Polymers and Bubbles
2 nd International Symposium on Seawater Drag Reduction Busan, Korea, 23-26 MAY 2005 Micro-Optical Sensor Use in Boundary Layer Flows with Polymers and Bubbles D. Modarress, P. Svitek (Measurement Science
Handbook on the Ultrasonic Examination. Austenitic Welds
Handbook on the Ultrasonic Examination Austenitic Welds The International Institute of Welding Edition Handbook On the Ultrasonic Examination of Austenitic Welds Compiled by COMMISSION V Testing, Measurement,
Vascular Technology (VT) Content Outline Anatomy & physiology 20% Cerebrovascular Cerebrovascular normal anatomy Evaluate the cerebrovascular vessels
Vascular Technology (VT) Content Outline Anatomy & physiology 20% normal anatomy Evaluate the cerebrovascular vessels hemodynamics Evaluate the cerebrovascular vessels for normal perfusion normal anatomy
Duplex Carotid Sonography in Distinguishing Acute Unilateral Atherothrombotic from Cardioembolic Carotid Artery Occlusion
Duplex Carotid Sonography in Distinguishing Acute Unilateral Atherothrombotic from Cardioembolic Carotid Artery Occlusion Kazumi Kimura, Kiminobu Yonemura, Tadashi Terasaki, Yoichiro Hashimoto, and Makoto
Acousto-optic modulator
1 of 3 Acousto-optic modulator F An acousto-optic modulator (AOM), also called a Bragg cell, uses the acousto-optic effect to diffract and shift the frequency of light using sound waves (usually at radio-frequency).
Introduction to Geiger Counters
Introduction to Geiger Counters A Geiger counter (Geiger-Muller tube) is a device used for the detection and measurement of all types of radiation: alpha, beta and gamma radiation. Basically it consists
PRINCIPLES OF DOPPLER ECHOCARDIOGRAPHY AND THE DOPPLER EXAMINATION #1
PRINCIPLES OF DOPPLER ECHOCARDIOGRAPHY AND THE DOPPLER EXAMINATION #1 Joseph A. Kisslo, MD David B. Adams, RDCS INTRODUCTION Doppler echocardiography is a method for detecting the direction and velocity
Describing Sound Waves. Period. Frequency. Parameters used to completely characterize a sound wave. Chapter 3. Period Frequency Amplitude Power
Parameters used to completely characterize a sound wave Describing Sound Waves Chapter 3 Period Frequency Amplitude Power Intensity Speed Wave Length Period Defined as the time it take one wave vibrate
Radar Systems Engineering Lecture 6 Detection of Signals in Noise
Radar Systems Engineering Lecture 6 Detection of Signals in Noise Dr. Robert M. O Donnell Guest Lecturer Radar Systems Course 1 Detection 1/1/010 Block Diagram of Radar System Target Radar Cross Section
Email: [email protected]
USE OF VIRTUAL INSTRUMENTS IN RADIO AND ATMOSPHERIC EXPERIMENTS P.N. VIJAYAKUMAR, THOMAS JOHN AND S.C. GARG RADIO AND ATMOSPHERIC SCIENCE DIVISION, NATIONAL PHYSICAL LABORATORY, NEW DELHI 110012, INDIA
AN-007 APPLICATION NOTE MEASURING MAXIMUM SUBWOOFER OUTPUT ACCORDING ANSI/CEA-2010 STANDARD INTRODUCTION CEA-2010 (ANSI) TEST PROCEDURE
AUDIOMATICA AN-007 APPLICATION NOTE MEASURING MAXIMUM SUBWOOFER OUTPUT ACCORDING ANSI/CEA-2010 STANDARD by Daniele Ponteggia - [email protected] INTRODUCTION The Consumer Electronics Association (CEA),
Analysis of free reed attack transients
Analysis of free reed attack transients James Cottingham Physics Department, Coe College, Cedar Rapids, Iowa, United States Summary Attack transients of harmonium-type free reeds from American reed organs
SAMSUNG ULTRASOUND RS80A
Samsung Medison is a global leading medical device company. Founded in 1985, the company sells cutting-edge diagnostic ultrasound devices around the world in various medical fields. The company has attracted
Fellow TEE Review Workshop Hemodynamic Calculations 2013. Director, Intraoperative TEE Program. Johns Hopkins School of Medicine
Fellow TEE Review Workshop Hemodynamic Calculations 2013 Mary Beth Brady, MD, FASE Director, Intraoperative TEE Program Johns Hopkins School of Medicine At the conclusion of the workshop, the participants
3. Experimental Results
Experimental study of the wind effect on the focusing of transient wave groups J.P. Giovanangeli 1), C. Kharif 1) and E. Pelinovsky 1,) 1) Institut de Recherche sur les Phénomènes Hors Equilibre, Laboratoire
Drive circuit basics + V. τ e. Industrial Circuits Application Note. Winding resistance and inductance
ndustrial Circuits Application Note Drive circuit basics For a given size of a stepper motor, a limited space is available for the windings. n the process of optimizing a stepper motor drive system, an
NON-DESTRUCTIVE METHODS. CE 165: Concrete Materials and Concrete Construction
NON-DESTRUCTIVE METHODS NON-DESTRUCTIVE METHODS Purpose: quick assessment of the structure Non-Destructive Techniques Many industrialized nations currently dedicate a considerable portion of the construction
Index-Velocity Rating Development for Rapidly Changing Flows in an Irrigation Canal Using Broadband StreamPro ADCP and ChannelMaster H-ADCP
Index-Velocity Rating Development for Rapidly Changing Flows in an Irrigation Canal Using Broadband StreamPro ADCP and ChannelMaster H-ADCP HENING HUANG, RD Instruments, 9855 Businesspark Avenue, San Diego,
Optical Fibres. Introduction. Safety precautions. For your safety. For the safety of the apparatus
Please do not remove this manual from from the lab. It is available at www.cm.ph.bham.ac.uk/y2lab Optics Introduction Optical fibres are widely used for transmitting data at high speeds. In this experiment,
Signal to Noise Instrumental Excel Assignment
Signal to Noise Instrumental Excel Assignment Instrumental methods, as all techniques involved in physical measurements, are limited by both the precision and accuracy. The precision and accuracy of a
Introduction to acoustic imaging
Introduction to acoustic imaging Contents 1 Propagation of acoustic waves 3 1.1 Wave types.......................................... 3 1.2 Mathematical formulation.................................. 4 1.3
Ultrasound in Vascular Surgery. Torbjørn Dahl
Ultrasound in Vascular Surgery Torbjørn Dahl 1 The field of vascular surgery Veins dilatation and obstruction (varicose veins and valve dysfunction) Arteries dilatation and narrowing (aneurysms and atherosclerosis)
Steven R. McManus Environmental Product Support Teledyne Isco
Steven R. McManus Environmental Product Support Teledyne Isco Flow Measurement Applications and Technologies. Methods of flow measurement Technologies of flow measurement Flow Rate Applications Channel
Various Technics of Liquids and Solids Level Measurements. (Part 3)
(Part 3) In part one of this series of articles, level measurement using a floating system was discusses and the instruments were recommended for each application. In the second part of these articles,
Realtime FFT processing in Rohde & Schwarz receivers
Realtime FFT in Rohde & Schwarz receivers Radiomonitoring & Radiolocation Application Brochure 01.00 Realtime FFT in Rohde & Schwarz receivers Introduction This application brochure describes the sophisticated
Contents. Introduction. 1. Doppler ultrasound: principles and practice (Colin Deane)
Contents Introduction 1. Doppler ultrasound: principles and practice (Colin Deane) Introduction Basic principles Continuous wave and pulsed wave Ultrasound flow modes Factors affecting the color flow image
Duplication Images in Vascular Sonography
Article Duplication Images in Vascular Sonography Jonathan M. Rubin, MD, PhD, Jing Gao, MD, Keith Hetel, MD, Robert Min, MD Objective. The purpose of this study was to determine the characteristics and
A pulse is a collection of cycles that travel together. the cycles ( on or transmit time), and. the dead time ( off or receive time)
chapter 2 Pulsed Ultrasound In diagnostic ultrasound imaging, short bursts, or pulses, of acoustic energy are used to create anatomic images. Continuous wave sound cannot create anatomic images. Analogy
SR2000 FREQUENCY MONITOR
SR2000 FREQUENCY MONITOR THE FFT SEARCH FUNCTION IN DETAILS FFT Search is a signal search using FFT (Fast Fourier Transform) technology. The FFT search function first appeared with the SR2000 Frequency
Vascular Laboratory Education and Training
Vascular Laboratory Education and Training David L. Dawson, MD, RVT, RPVI Vascular laboratory professionals technologists and physicians have specific knowledge and expertise in the use of non- invasive
Rouleaux flow, Sagittal. Rouleaux flow, transverse. Doppler Overview. Doppler Overview. Why we hate Doppler physics!!
Doppler Technology & Optimization Doppler From A Z Donald T. Milburn, RDCS, RVT, FSDMS Prescott, Az. San Diego local ultrasound society May 12, 2009 Donald T. Milburn, RDCS, RVT, NACT, FSDMS Director,
Switch Mode Power Supply Topologies
Switch Mode Power Supply Topologies The Buck Converter 2008 Microchip Technology Incorporated. All Rights Reserved. WebSeminar Title Slide 1 Welcome to this Web seminar on Switch Mode Power Supply Topologies.
Module 13 : Measurements on Fiber Optic Systems
Module 13 : Measurements on Fiber Optic Systems Lecture : Measurements on Fiber Optic Systems Objectives In this lecture you will learn the following Measurements on Fiber Optic Systems Attenuation (Loss)
Impact Echo Scanning Technology for Internal Grout Condition Evaluation in Post-Tensioned Bridge Ducts
Impact Echo Scanning Technology for Internal Grout Condition Evaluation in Post-Tensioned Bridge Ducts Yajai Tinkey, Ph.D. Olson Engineering, Wheat Ridge, Colorado Larry D. Olson, P.E. Olson Engineering,
PROCESS PARTICLE COUNTER (PPC) SENSOR/CONTROLLER FOR OPTIMIZING POWER RECOVERY EXPANDER AND GAS TURBINE PERFORMANCE
PROCESS PARTICLE COUNTER (PPC) SENSOR/CONTROLLER FOR OPTIMIZING POWER RECOVERY EXPANDER AND GAS TURBINE PERFORMANCE APPLICATIONS NOTE FOR MEASUREMENTS AT THE ENTRANCE AND EXIT OF A THIRD STAGE SEPARATOR
Development of Optical Wave Microphone Measuring Sound Waves with No Diaphragm
Progress In Electromagnetics Research Symposium Proceedings, Taipei, March 5 8, 3 359 Development of Optical Wave Microphone Measuring Sound Waves with No Diaphragm Yoshito Sonoda, Takashi Samatsu, and
High-Resolution Doppler-Polarimetric FMCW Radar with Dual-Orthogonal Signals
High-Resolution Doppler-Polarimetric FMCW Radar with Dual-Orthogonal Signals Oleg Krasnov, Leo Ligthart, Zhijian Li, Galina Babur, Zongbo Wang, Fred van der Zwan International Research Centre for Telecommunications
Ultrasonic Wave Propagation Review
Ultrasonic Wave Propagation Review Presented by: Sami El-Ali 1 1. Introduction Ultrasonic refers to any study or application of sound waves that are higher frequency than the human audible range. Ultrasonic
Upper Extremity Arterial Duplex Evaluation
VASCULAR TECHNOLOGY PROFESSIONAL PERFORMANCE GUIDELINES Upper Extremity Arterial Duplex Evaluation This Guideline was prepared by the Professional Guidelines Subcommittee of the Society for Vascular Ultrasound
FTIR Instrumentation
FTIR Instrumentation Adopted from the FTIR lab instruction by H.-N. Hsieh, New Jersey Institute of Technology: http://www-ec.njit.edu/~hsieh/ene669/ftir.html 1. IR Instrumentation Two types of instrumentation
Step Response of RC Circuits
Step Response of RC Circuits 1. OBJECTIVES...2 2. REFERENCE...2 3. CIRCUITS...2 4. COMPONENTS AND SPECIFICATIONS...3 QUANTITY...3 DESCRIPTION...3 COMMENTS...3 5. DISCUSSION...3 5.1 SOURCE RESISTANCE...3
MUSIC-like Processing of Pulsed Continuous Wave Signals in Active Sonar Experiments
23rd European Signal Processing Conference EUSIPCO) MUSIC-like Processing of Pulsed Continuous Wave Signals in Active Sonar Experiments Hock Siong LIM hales Research and echnology, Singapore hales Solutions
Scanning Acoustic Microscopy Training
Scanning Acoustic Microscopy Training This presentation and images are copyrighted by Sonix, Inc. They may not be copied, reproduced, modified, published, uploaded, posted, transmitted, or distributed
Vtial sign #1: PULSE. Vital Signs: Assessment and Interpretation. Factors that influence pulse rate: Importance of Vital Signs
Vital Signs: Assessment and Interpretation Elma I. LeDoux, MD, FACP, FACC Associate Professor of Medicine Vtial sign #1: PULSE Reflects heart rate (resting 60-90/min) Should be strong and regular Use 2
Optimizing VCO PLL Evaluations & PLL Synthesizer Designs
Optimizing VCO PLL Evaluations & PLL Synthesizer Designs Today s mobile communications systems demand higher communication quality, higher data rates, higher operation, and more channels per unit bandwidth.
Space Environment and Satellite Systems: Removing Clutter from Ground-to-Satellite Signals. Sigrid Close
Space Environment and Satellite Systems: Removing Clutter from Ground-to-Satellite Signals Sigrid Close Background Overview RF propagation through ionosphere can be problematic Goals Traditionally too
Phased Array Ultrasonic Inspection Of 25%Cr Super Duplex Stainless Steel. On Subsea Manifold Piping Girth Welds In Lieu Of Radiography
National Seminar & Exhibition on Non-Destructive Evaluation, NDE 2014, Pune, December 4-6, 2014 (NDE-India 2014) Vol.20 No.6 (June 2015) - The e-journal of Nondestructive Testing - ISSN 1435-4934 www.ndt.net/?id=17866
Advancements in High Frequency, High Resolution Acoustic Micro Imaging for Thin Silicon Applications
Advancements in High Frequency, High Resolution Acoustic Micro Imaging for Thin Silicon Applications Janet E. Semmens Sonoscan, Inc. 2149 E. Pratt Boulevard Elk Grove Village, IL 60007 USA Phone: (847)
Ralph L. Brooker, Member, IEEE. Andrew Corporation, Alexandria, VA 22314, USA
Spectral-Null Pulse Waveform For Characterizing Gain and Phase Distortion in Devices with Uncorrelated Frequency Translation or Limited CW Power Capability Ralph L. Brooker, Member, IEEE Andrew Corporation,
The Fourier Analysis Tool in Microsoft Excel
The Fourier Analysis Tool in Microsoft Excel Douglas A. Kerr Issue March 4, 2009 ABSTRACT AD ITRODUCTIO The spreadsheet application Microsoft Excel includes a tool that will calculate the discrete Fourier
Extended spectral coverage of BWO combined with frequency multipliers
Extended spectral coverage of BWO combined with frequency multipliers Walter C. Hurlbut, Vladimir G. Kozlov, Microtech Instruments, Inc. (United States) Abstract: Solid state frequency multipliers extend
Ultrasound. for Vascular Access and Regional Anesthesia. Brian A. Pollard, md, med
Ultrasound Guidance for Vascular Access and Regional Anesthesia Brian A. Pollard, md, med ULTRASOUND GUIDANCE for Vascular Access and Regional Anesthesia Brian A. Pollard BSc, MD, MEd, FRCPC www.usrabook.com
Linear Parameter Measurement (LPM)
(LPM) Module of the R&D SYSTEM FEATURES Identifies linear transducer model Measures suspension creep LS-fitting in impedance LS-fitting in displacement (optional) Single-step measurement with laser sensor
RF-thermal-structural-RF coupled analysis on the travelling wave disk-loaded accelerating structure
RF-thermal-structural-RF coupled analysis on the travelling wave disk-loaded accelerating structure PEI Shi-Lun( 裴 士 伦 ) 1) CHI Yun-Long( 池 云 龙 ) ZHANG Jing-Ru( 张 敬 如 ) HOU Mi( 侯 汨 ) LI Xiao-Ping( 李 小
Samsung Ultrasound H60
Samsung Medison is a global leading medical devices company. Founded in 1985, the company now sells cutting-edge medical devices including diagnostic ultrasound, digital X-ray and blood analyzer around
Trace Gas Exchange Measurements with Standard Infrared Analyzers
Practical Environmental Measurement Methods Trace Gas Exchange Measurements with Standard Infrared Analyzers Last change of document: February 23, 2007 Supervisor: Charles Robert Room no: S 4381 ph: 4352
Subclavian Steal Syndrome By Marta Thorup
Subclavian Steal Syndrome By Marta Thorup Definition Subclavian steal syndrome (SSS), is a constellation of signs and symptoms that arise from retrograde flow of blood in the vertebral artery, due to proximal
Line Reactors and AC Drives
Line Reactors and AC Drives Rockwell Automation Mequon Wisconsin Quite often, line and load reactors are installed on AC drives without a solid understanding of why or what the positive and negative consequences
Ny teknologi: Fagdagene ved St. Olavs Hospital Lasse Løvstakken Dept. Circulation and Medical Imaging 11.06.2010
1 Ny teknologi: Ultralyd måler m blodstrøm Fagdagene ved St. Olavs Hospital Lasse Løvstakken Dept. Circulation and Medical Imaging 11.06.2010 2 Conventional imaging methods of blood flow using ultrasound
8.1 Radio Emission from Solar System objects
8.1 Radio Emission from Solar System objects 8.1.1 Moon and Terrestrial planets At visible wavelengths all the emission seen from these objects is due to light reflected from the sun. However at radio
Self-Mixing Laser Diode Vibrometer with Wide Dynamic Range
Self-Mixing Laser Diode Vibrometer with Wide Dynamic Range G. Giuliani,, S. Donati, L. Monti -, Italy Outline Conventional Laser vibrometry (LDV) Self-mixing interferometry Self-mixing vibrometer Principle: