TYPE "A" AND TYPE "B" CONSTANT DOWNSTREAM LEVEL CONTROL GATES TYPE "A" FOR OPEN CHANNEL FLOWS F.P.O. TYPE "B" FOR ORIFICE APPLICATIONS WATERMAN
|
|
|
- Kory Blair
- 9 years ago
- Views:
Transcription
1 WATERMAN TYPE "A" AND TYPE "B" CONSTANT DOWNSTREAM LEVEL CONTROL GATES AUTOMATIC NO OPERATOR, NO MOTOR SIMPLE, ACCURATE, FAST AND RELIABLE FOR FLOOD CONTROL FOR WATER MANAGEMENT SYSTEMS FOR IRRIGATION CONSTANT DOWNSTREAM LEVEL CONTROL TYPE "A" FOR OPEN CHANNEL FLOWS F.P.O. TYPE "B" FOR ORIFICE APPLICATIONS 21
2 WATERMAN TYPE "A" AND TYPE "B" CONSTANT DOWNSTREAM LEVEL CONTROL GATES Automatic gates provide constant downstream water level control regardless of upstream level conditions or downstream demands. This remarkably constant control is achieved without any operators, without motors or power supply, and irrespective of upstream level conditions. These Waterman Type "A" and Type "B" gates are designed to respond automatically and instantly to downstream level changes to maintain a constant downstream water level. They are ideally suited for: "Demand control" on open canals Canal and network automation Control of detention basins and reservoirs Flood Control Channel water level maintenance "Constant source" flow for cooling and recirculation systems and water and wastewater treatment facilities. Constant downstream discharge when used with a Waterman baffle distributor Control of head (headbreaking) Type "B" gate located on the outlet of a large storm water detention basin.. Type "A" gate located as a regulator on a small irrigation canal. 22
3 PRINCIPLE OF OPERATION With the downstream water level at the pivot axis, the gate is balanced so that the moment caused by the center of gravity about the hinge is equal to the moment caused by the upthrust of the float. Any change in the water level alters this stability, causing the gate to rotate, thereby increasing or decreasing the discharge to restore the water level to the pivot centerline. If the water level falls, the reduced flotation couple allows the gate to open increasing the discharge into the downstream channel. Conversely, if the water level rises, the increased flotation couple shuts the gate, decreasing the discharge and maintaining the water level at the pivot centerline. TYPE "A" Maximum upstream head 6.5 Ft. for largest gates No breastwall Designed for continuous canal lengths with upstream level variations relatively small. TYPE "B" Maximum upstream head 36 Ft. for largest gates Breastwall or other orifice needed Designed for higher heads and greater upstream level requirements working against breastwall or other opening. GATE CONSTRUCTION The Waterman Type "A" and Type "B" constant downstream level gates basically consist of a radial leaf of trapezoidal shape, a float that is rigidly fixed to the moving frame downstream of the pivot axis, a float shield tank in which the inlet butterfly valve is fixed, a counterweight tank and a frame structure which consists of the main shaft with bearings and beams connecting the float to the gate leaf. The walkway is a standard feature for all larger sizes of Waterman Type "A" and Type "B" gates. Waterman Type "A" gate has a damper on the upstream surface of the leaf and bottom/sides metal seats. Waterman Type "B" gate has an embedded metal intake structure. 23
4 THE WATERMAN TYPE "A" Waterman Type "A" gates are designed to maintain a constant downstream water level irrespective of the upstream variations, provided that the upstream level variations are small enough to be satisfied by a surface gate. Two Type "A" configurations are available. The low head has a wider gate leaf of lesser height, while the high head gate leaf is not as wide, but has greater height. At equal loss of head, a Waterman Type "A" low head gate allows a bigger flow, but the maximum permissible head is less. Cutaway drawing of a Waterman Type "A" gate installation GATE SELECTION Selection is based on the required hydraulic performanance of the installation. The gate to be selected is the smallest one (smallest index number) whose head-discharge curve, represented on the selection charts, encompasses all possible head/discharge operating points which may be encountered for the installation. For example, the following differential the maximum discharge 1 under which 2 must still be delivered. 1 and 2 define point A Maximum head differential 3 and largest discharge 4 to be delivered under this maximum head differential. 3 and 4 define point B See following page. 24
5 TYPE "A" LOW HEAD GATE SELECTION CHART TYPE "A" HIGH HEAD GATE SELECTION CHART 25
6 EXAMPLE I: Water flows from a reservoir to a canal. What gate should be used to control the flow from the reservoir in order to maintain a constant water level in the canal irrespective of the level in the reservoir and irrespective of the water demand? withdrawal rate varies from 15 to 250 cfs level in the reservoir can fluctuate between and ft. desired Constant Level in canal: ft. Point A 1 is defined by: = 0.90 ft cfs Point B 1 is defined by: = 7.00 ft cfs The Type B-16 is the smallest gate whose characteristics encompass A 1 and B 1 and is therefore the gate to be selected. Note that no Type "A" gate will answer the problem: the Type B-21 could, but this gate is much larger than the Type B-16. EXAMPLE II: A control structure is to be installed in a canal to maintain a constant downstream water level irrespective of the discharge in the canal. desired constant downstream level: ft at maximum flow of 100 cfs the water level in the canal upstream of the structure is ft at minimum flow of 30 cfs the water level in the canal upstream of the structure is ft Point A 2 is defined by: = 0.10 ft cfs Point B 2 is defined by: = 3.00 ft 4 30 cfs. The Type A-18, Type A-7, Type B-18 and Type B-21 have characteristics which encompass A 2 and B 2. However, since the Type A- 7 is the smallest, it is the gate to be selected. High Head TYPE A Low Head Overal Dimensions A B* C* D E F R r Jm dm b e g a b c A A A A A A A A A A A A A A A A A A A A DIMENSIONS IN INCHES * Dimensions are approximate and subject to change. 26
7 TYPICAL SPECIFICATION FOR WATERMAN TYPE "A" AUTOMATIC LEVEL CONTROL GATE 1. APPLICABLE PUBLICATIONS. The Steel Structures Painting Council (SSPC) Publications listed below form a part of this specification to the extent referenced. The publications are referred to in the text by the basic designation only SSPC SP 10 Near White Blast Clean SSPC PS (1982) Black (or Dark Red) Coal Tar Epoxy Painting System 2. SUBMITTALS 2.1 Shop Drawings. Shop drawings shall be submitted in accordance with the SPECIAL CLAUSES. Submittals shall include a complete list of equipment and materials, including manufacturer's descriptive and technical literature, performance charts and curves, catalog cuts, and installation instructions. Drawings shall show proposed layout and anchorage of the system and appurtenances, design of structure to receive gates and equipment relationship to other parts of the work including clearances for maintenance and operation. Manufacturer's descriptive data and installation instructions shall be submitted for approval. 2.2 Certificate of Compliance. A certificate of compliance that the gates furnished are in conformance with the drawings and specifications shall be submitted to the project engineer. 2.3 Operating Instructions. The manufacturer shall furnish the engineer with six (6) complete copies of operating characteristics and instructions outlining the step-by-step procedure required for system start-up and system operation. The instructions shall include the manufacturer's name, model number, service manual, parts list, and brief description of all equipment and their basic operating features. 2.4 Maintenance Instructions. The manufacturer shall furnish the engineer with six (6) copies of maintenance instructions listing routine maintenance procedures, possible breakdown and repairs, and troubleshooting guide. 2.5 Spare Parts Data. After approval of the shop drawings, the contractor shall furnish spare parts data for each different item of materials and equipment furnished. Data shall include a complete list of spare parts and supplies, with current unit prices and source of supply. 3. MANUFACTURER'S SERVICES. The Contractor shall obtain the services of a factory field representative experienced in the calibration and balancing of the equipment specified. The representative shall supervise the calibration and balancing of the equipment for proper operation. 4. SHIPMENT AND DELIVERY. Gates shall be shipped from factory in components or sub-assemblies to be bolted together in the field to the exclusion of any field welding. The dimensions of individual components shall be compatible with rail or road transportations clearances. Match marks shall be provided on the heaviest components to facilitate field erection. When shipping and delivering gate components, the gates shall be handled carefully to ensure a sound, undamaged condition. Particular care shall be taken not to damage any coating. 5. MATERIALS. 5.1 General. The automatic level control gate shall be constant downstream level, Waterman Type "A", and be completely self-operating with an integrated float-ballast design. The gate shall be as manufactured by Waterman Industries, Inc.,or an approved equal in quality, characteristics and performance. 5.2 Steel shall be ASTM A
8 TYPICAL SPECIFICATION FOR WATERMAN TYPE "A" AUTOMATIC LEVEL CONTROL GATE (CONTINUED) 5.3 Standard Products. Materials and equipment shall be the standard product of a manufacturer regularly engaged in the manufacture of this type of product and shall essentially duplicate items that have been in satisfactory service for more than five (5) years prior to bid opening. Substitute manufacturer may submit alternate design which has been tested and certified by an independent laboratory. All materials used in construction of the gate shall be new and selected according to the best engineering practice for this type of equipment. Equipment shall be supported by a service organization that is, in the opinion of the engineer, reasonably convenient to the site. 6. OPERATION REQUIREMENTS. The gate shall operate automatically, regulating the downstream water level with no external power, motor or level sensors and hoists, and no manual intervention, under the following conditions: (insert your particulars here, such as elevations, head differential and flows) 6.1 Within the above specified limits, the downstream level shall be controlled irrespective of the upstream level conditions, gate opening and discharge rates. 7. GATE CONSTRUCTION. 7.1 The gates shall be fabricated from materials as per paragraph 5, Materials, and designed to withstand the pressure forced produced by the upstream water level at it's maximum elevation, with no tailwater (and, as the case may be, by the exceptional maximum tailwater level). 7.2 The gates shall mainly consist of a radially shaped faceplate, suitably reinforced and matching trapezoidalshaped sluice way, a framework including the float and ballasting compartments, and two roller bearings enclosed in sealed housings to be anchored in the concrete structure. 7.3 The float ballast compartment shall be protected by a shield specially designed to prevent any silt deposit likely to impair the traveling of the moving assembly. 7.4 The gates shall include an adjustable counterweight, suitable for accurate, sensitive and stable gate operation. The leakage rate in the closed position shall not exceed 3 cfs. The gate shall be carefully checked and adjusted to tolerances required in the factory for straight forward field erection and proper operation. 8.0 SURFACE PREPARATION AND PAINTING. Surface preparation shall consist of near white blast cleaning of all surfaces (SSPC SP-10). Mechanical surfaces shall be protected by appropriate masking. Protective coating shall consist of: a. On machined surfaces, one coat of gasoline-soluble, rust-preventing compound. b. On all other surfaces, including surfaces to be grouted in, two coats of factory applied coal tar epoxy paint (SSPC PS 11.01) for corrosion protection from water and corrosive environment. c. Coating touch-up kit. (Alternate surface preparations and coatings may be specified.) 28
9 THE WATERMAN TYPE "B" AUTOMATIC DOWNSTREAM LEVEL CONTROL GATE Waterman Type "B" gates are designed for sluice installations, usually controlling an orifice set in a breastwall, and permitting a higher upstream head. Cutaway drawing of a Waterman Type "B" gate installation (note breastwall and optional stop gate) Low head Waterman Type "B" gates differ from the high head type by their gate leaf, which is twice as wide. For equal head losses, they have twice the flow capacity as the high head, but the maximum permissible head is reduced by half. GATE SELECTION Selection is based on the required hydraulic performance of the installation. The gate to be selected is the smallest one (smallest index number) whose head-discharge curve, represented on the selection charts, encompasses all possible head/discharge operating points which may be encountered for the installation. For example, the following data are typical and define two significant operating points, A and B: Minimum head differential 1 under which the maximum discharge 2 must be delivered. 1 and 2 define point A. Maximum head differential 3 and largest discharge 4 to be delivered under this maximum head differential. 3 and 4 define point B. See following page. 29
10 TYPE "B" LOW HEAD GATE SELECTION CHART TYPE "B" HIGH HEAD GATE SELECTION CHART 30
11 EXAMPLE I: Water flows from a reservoir to a canal. What gate should be used to control the flow from the reservoir in order to maintain a constant water level in the canal irrespective of the level in the reservoir and irrespective of the water demand? withdrawal rate varies from 15 to 250 cfs level in the reservoir can fluctuate between and ft. desired Constant Level in canal: ft. Point A 1 is defined by: = 0.90 ft cfs Point B 1 is defined by: = 7.00 ft cfs EXAMPLE II: A control structure is to be installed in a canal to maintain a constant downstream water level irrespective of the discharge in the canal. desired constant downstream level: ft at maximum flow of 100 cfs the water level in the canal upstream of the structure is ft at minimum flow of 30 cfs the water level in the canal upstream of the structure is ft Point A 1 is defined by: = 0.10 ft cfs Point B 2 is defined by: = 3.00 ft cfs The Type B-16 is the smallest gate whose characteristics encompass A 1 and B 1 and is therefore the gate to be selected. Note that no Type "A" gate will answer the problem: the Type B-21 could, but this gate is much larger than the Type B-16. The Type A-18, Type A-7, Type B-18 and Type B-21 have characteristics which encompass A 2 and B 2. However, since the Type A-7 is the smallest, it is the gate to be selected. High-head and Low-head Waterman Type B Gates from B-1 to B-26 High Head TYPE B Low Head Overal Dimensions Max. Head Opening A* B C R r Jm h L B B B B B B B B B B B B B B B B B B B B B B B B B B DIMENSIONS IN INCHES * Dimensions are approximate and subject to change. 31
12 TYPICAL SPECIFICATION FOR WATERMAN TYPE "B" AUTOMATIC LEVEL CONTROL GATE 1. APPLICABLE PUBLICATIONS. The Steel Structures Painting Council (SSPC) Publications listed below form a part of this specification to the extent referenced. The publications are referred to in the text by the basic designation only SSPC SP 10 SSPC PS Near White Blast Clean (1982) Black (or Dark Red) Coal Tar Epoxy Painting System 2. SUBMITTALS 2.1 Shop Drawings. Shop drawings shall be submitted in accordance with the SPECIAL CLAUSES. Submittals shall include a complete list of equipment and materials, including manufacturer's descriptive and technical literature, performance charts and curves, catalog cuts, and installation instructions. Drawings shall show proposed layout and anchorage of the system and appurtenances, design of structure to receive gates and equipment relationship to other parts of the work including clearances for maintenance and operation. Manufacturer's descriptive data and installation instructions shall be submitted for approval. 2.2 Certificate of Compliance. A certificate of compliance that the gates furnished are in conformance with the drawings and specifications shall be submitted to the project engineer. 2.3 Operating Instructions. The manufacturer shall furnish the engineer with six (6) complete copies of operating characteristics and instructions outlining the step-by-step procedure required for system start-up and system operation. The instructions shall include the manufacturer's name, model number, service manual, parts list, and brief description of all equipment and their basic operating features. 2.4 Maintenance Instructions. The manufacturer shall furnish the engineer with six (6) copies of maintenance instructions listing routine maintenance procedures, possible breakdown and repairs, and troubleshooting guide. 2.5 Spare Parts Data. After approval of the shop drawings, the contractor shall furnish spare parts data for each different item of materials and equipment furnished. Data shall include a complete list of spare parts and supplies, with current unit prices and source of supply. 3. MANUFACTURER'S SERVICES. The Contractor shall obtain the services of a factory field representative experienced in the calibration and balancing of the equipment specified. The representative shall supervise the calibration and balancing of the equipment for proper operation. 4. SHIPMENT AND DELIVERY. Gates shall be shipped from factory in components or sub-assemblies to be bolted together in the field to the exclusion of any field welding. The dimensions of individual components shall be compatible with rail or road transportations clearances. Match marks shall be provided on the heaviest components to facilitate field erection. When shipping and delivering gate components, the gates shall be handled carefully to ensure a sound, undamaged condition. Particular care shall be taken not to damage any coating. 5. MATERIALS. 5.1 General. The automatic level control gate shall be constant downstream level, Waterman Type "B", and be completely self-operating with an integrated float-ballast design. The gate shall be as manufactured by Waterman Industries, Inc., or an approved equal in quality, characteristics and performance. 32
13 TYPICAL SPECIFICATION FOR WATERMAN TYPE "B" AUTOMATIC LEVEL CONTROL GATE (CONTINUED) 5.2 Steel shall be ASTM A Standard Products. Materials and equipment shall be the standard product of a manufacturer regularly engaged in the manufacture of this type of product and shall essentially duplicate items that have been in satisfactory service for more than five (5) years prior to bid opening. Substitute manufacturer may submit alternate design which has been tested and certified by an independent laboratory. All materials used in construction of the gate shall be new and selected according to the best engineering practice for this type of equipment. Equipment shall be supported by a service organization that is, in the opinion of the engineer, reasonably convenient to the site. 6. OPERATION REQUIREMENTS. The gate shall operate automatically, regulating the downstream water level with no external power, motor or level sensors and hoists, and no manual intervention, under the following conditions: (insert your particulars here, such as elevations, head differential and flows) 6.1 Within the above specified limits, the downstream level shall be controlled irrespective of the upstream level conditions, gate opening and discharge rates. 7. GATE CONSTRUCTION. 7.1 The gates shall be fabricated from materials as per paragraph 5, Materials, and designed to withstand the pressure forced produced by the upstream water level at it's maximum elevation, with no tailwater (and, as the case may be, by the exceptional maximum tailwater level). 7.2 The gates shall mainly consist of a radially shaped faceplate, suitably reinforced and matching trapezoidalshaped sluice way, a framework including the float and ballasting compartments, and two roller bearings enclosed in sealed housings to be anchored in the concrete structure. 7.3 The float ballast compartment shall be protected by a shield specially designed to prevent any silt deposit likely to impair the traveling of the moving assembly. 7.4 The gates shall include an adjustable counterweight, suitable for accurate, sensitive and stable gate operation. The leakage rate in the closed position shall not exceed 3 cfs. The gate shall be carefully checked and adjusted to tolerances required in the factory for straight forward field erection and proper operation. 8.0 SURFACE PREPARATION AND PAINTING. Surface preparation shall consist of near white blast cleaning of all surfaces (SSPC SP 10). Mechanical surfaces shall be protected by appropriate masking. Protective coating shall consist of: a. On machined surfaces, one coat of gasoline-soluble, rust-preventing compound. b. On all other surfaces, including surfaces to be grouted in, two coats of factory applied coal tar epoxy paint (SSPC PS 11.01) for corrosion protection from water and corrosive environment. c. Coating touch-up kit. (Alternate surface preparations and coatings may be specified.) 33
14 Control of Detention Basin Outlets: A Typical Application of the WATERMAN TYPE "B" CONSTANT DOWNSTREAM LEVEL GATE NORMAL FLOW CONDITION The Type "B" Gate is fully open and remains conveniently out of the flow. Large cross section area of the sluice minimizes chances of clogging. As long as the runoff does not exceed the downstream canal full capability the detention basin is kept empty, its storage capacity available to its maximum value. FLOOD CONDITION When, and only when, the incoming runoff exceeds the canal capacity does the Type "B" Gate back up the excess flow in the detention basin. Maintaining a constant water line at the head of the canal the Type "B" Gate releases only the discharge that can be handled. Computer? Electronics? Motors? No! Not even a single switch... and yet the sturdy Type "B" Gate does precisely what is required from a detention basin outlet. With the Waterman Type "B" Gates, costly detention basins and draining canals become 100% efficient. TYPE "A" / TYPE "B" Gate Applications Demand Control - The headworks to an open canal can be automated with the use of Waterman Type "A"/Type "B" downstream level control gates providing required flows "on demand." Irrigation Canals - Automatic canal check gates for reliable turnout control at "demand" flows. Flood Control Constant Source Flow Wastewater Treatment - Control of detention basin outlets. Basins are kept empty until the runoff exceeds the downstream canal full capability at which time the Waterman Type "A"/Type "B" gates will back up the flow in the detention basin. The gates release only the discharge that can be handled. - Provides needed supply to cooling water recirculation systems or wet-wells for pump stations. - Flow through the headworks can be equalized during peak and off-peak hours by using a Waterman Type "A"/Type "B" downstream control gate as the main influent gate. During peak flows the excess will be retained upstream of the gate and during off-peak flows the gate would remain open. - By using the Waterman Type "A"/Type "B" gate as a "demand control" device sedimentation basin levels can be automatically regulated during fluctuating flow rates. 34
15 TYPICAL DETENTION BASIN APPLICATION Redbank Creek detention basin. Downstream side of dam showing outlet control structure. Upstream side of dam showing manual sluice gates which are used when complete shut-off is desired. 35
Mechanical Installation
Page -1-1. INTRODUCTION AND PURPOSE 1.1. This specification covers the installation, testing and precommissioning of mechanical equipment. Work is to be performed in conjunction with the manufacturer s
CCU Engineering Specifications. Section 003300 PRECAST CONCRETE PRODUCTS
CCU Engineering Specifications Section 003300 Effective Date: Nov. 1st, 2011 Page 1 of 5 PRECAST CONCRETE PRODUCTS PART 1 - GENERAL The following specification is intended for use for the design, selection
PTS HELICAL PIERS INSTALLATION SPECIFICATIONS NOTICE
FORM A PTS HELICAL PIERS INSTALLATION SPECIFICATIONS NOTICE The following suggested specifications are written as a guide to assist the specifier in writing his own specifications. Specific circumstances
Wastewater Capital Projects Management Standard Construction Specification
CITY AND COUNTY OF DENVER ENGINEERING DIVISION Wastewater Capital Projects Management Standard Construction Specification 10.1 Precast Concrete Pipe 10.1.1 General This section covers material requirements,
SECTION 15076 CEMENT-MORTAR LINED AND COATED STEEL PIPE
SECTION 15076 CEMENT-MORTAR LINED AND COATED (CML&C) STEEL PIPE PART 1 GENERAL 1.01 DESCRIPTION This section designates the requirements for steel pipe fabrication, test in shop, installation of steel
BLADDER SURGE CONTROL SYSTEM
PART I GENERAL 1.01 Description BLADDER SURGE CONTROL SYSTEM This specification describes the requirements for a Bladder Surge Control System. The purpose of the system is to minimize transient pressures
SECTION 02400 - STORM DRAIN SYSTEM
SECTION 02400 - STORM DRAIN SYSTEM CONTENTS: Part 1 - General... 1 1.01 Work Included... 1 1.02 Related Requirements... 1 1.03 Reference Standards... 1 1.04 Quality Assurance... 1 1.05 Measurement And
VXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6
- B 1 Product Detail Engineering Data... B2 Structural Support... B6 Engineering Specifications... B9 - B 2 Engineering Data REMARK: Do not use for construction. Refer to factory certified dimensions &
SUPPLEMENTAL TECHNICAL SPECIFICATIONS BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS
July 14, 2015 1.0 GENERAL BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS This work shall consist of furnishing all materials, equipment, labor, and incidentals necessary for conducting bi-directional
BSM MOTOR DRIVEN CENTRIFUGAL PUMPS
PRINCIPLE OF OPERATION A hydraulically and dynamically balanced impeller with raised vane sections discharges liquid as a result of the centrifugal force developed in rotation. The head developed is entirely
SECTION 15410 GROUND WATER STORAGE TANKS
SECTION 15410 GROUND WATER STORAGE TANKS PART 1 GENERAL.01 SCOPE A. Section Includes Requirements for designing, fabricating, and erecting a welded steel ground storage tank..02 SYSTEM DESCRIPTION A. Design
SECTION 15 AIR RELEASE VALVE ASSEMBLIES. 15-1 General
SECTION 15 AIR RELEASE VALVE ASSEMBLIES 15-1.01 Scope 15-1 General This section describes the requirements for furnishing and installing Air Release Valve Assemblies of the size and type shown on the plans,
PRESSURE REDUCING CONTROL VALVE
Schematics Throttles to reduce high upstream pressure to constant lower downstream pressure Low Flow By-Pass controls at low flows 4 PRESSURE REDUCING CONTROL VALVE with LOW FLOW BY-PASS FEATURE Main Line
SECTION 03400 PRECAST CONCRETE STRUCTURES
SECTION 03400 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes specifications for precast concrete structures, including fabrication and erection. 1.02 REFERENCE STANDARDS A. American Society for
SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS
SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2
Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components
Schematic Throttles to reduce high upstream pressure to constant lower downstream pressure Throttles to maintain minimum upstream pressure PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE
AIR RELEASE, CLEANOUT, AND SEWER MANHOLES
AIR RELEASE, CLEANOUT, AND SEWER MANHOLES **From Hartford IM BLDG(10) DESCRIPTION. This work shall consist of the construction of air release, cleanout, and sanitary sewer manholes; and the furnishing
Outlet stabilization structure
Overview of Sedimentation and Erosion Control Practices Practice no. 6.41 Outlet stabilization structure Erosion at the outlet of channels, culverts, and other structures is common, and can cause structural
SANITARY SEWER SPECIFICATIONS
SANITARY SEWER SPECIFICATIONS OCTOBER 2003 HARVEST-MONROVIA WATER, SEWER, AND FIRE PROTECTION AUTHORITY SECTION 1.00 1.10 Purpose The purpose of this document is to assemble the sewer specifications, policies,
SECTION 33 12 19 FIRE HYDRANTS
SECTION 33 12 19 FIRE HYDRANTS PART 1: GENERAL 1.01 SCOPE A. Fire hydrants. B. Adjustment of fire hydrants and gate valves. 1.02 SUBMITTALS A. Conform to requirements of Section 01 33 00 - Submittals.
Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank
Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank This specification describes requirements for a Diesel Fuel Day Tank System consisting of one or more fuel tanks, an Electronic
Pump Skid Fabrication for Magnetic Coupling. Rick Soltis Chief Mechanic City of Bedford
Pump Skid Fabrication for Magnetic Coupling Rick Soltis Chief Mechanic City of Bedford Contents Magnetic Couplings What They Are, How They Work, Where They re Used Fabrication and Manufacturing of Pump
SECTION 02630 STORM DRAINAGE SYSTEM
SECTION 02630 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes specifications for storm drainage systems including modifications and connections to existing storm drainage systems. 1.02 REFERENCE
STRUCTURES. 1.1. Excavation and backfill for structures should conform to the topic EXCAVATION AND BACKFILL.
STRUCTURES 1. General. Critical structures may impact the integrity of a flood control project in several manners such as the excavation for construction of the structure, the type of foundation, backfill
D Youville College July 31, 2008 New Academic Building Cannon Design Project No. 002935.00
SECTION 22 6119 - COMPRESSED-AIR EQUIPMENT FOR LABORATORY AND HEALTHCARE PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged, oilless scroll air compressors. 1.2 DEFINITIONS A. Actual Air: Air
The Flow Regulator. Flow regulation
Flow regulation Overloading in sewerage works and drainage systems can be avoided by using an attenuation reservoir, or by directing flow to a less sensitive area. Automatic flow control in gravity fed
SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)
APPLICATIONS Process Industry Weak Acids Alkalies Compressed Air Pulp & Paper MODELS ASM - Flanged Connection OPTIONS Control Rods Oil & Gas Water & Waste Pump suction & discharge Sea water Chemical lines
APCO SLOW CLOSING AIR/VACUUM VALVES
BULLETIN 1 JULY 01 APCO SLOW CLOSING AIR/VACUUM VALVES Series 1900 APCO Slow Closing Air/Vacuum s Maximum Air Flow Velocity in Good Pipeline Design The Air/Vacuum operates in the normal fashion allowing
CHAPTER 17: STORM SEWER STANDARDS. 17.00 Introduction. 17.01 Administration. 17.02 Standards 17.1
CHAPTER 17: STORM SEWER STANDARDS 17.00 Introduction 17.01 Administration 17.02 Standards 17.1 17.00 INTRODUCTION The purpose of this chapter is to provide guidance for the design and construction of storm
Emergency Spillways (Sediment basins)
Emergency Spillways (Sediment basins) DRAINAGE CONTROL TECHNIQUE Low Gradient Velocity Control Short-Term Steep Gradient Channel Lining Medium-Long Term Outlet Control Soil Treatment Permanent [1] [1]
Design & Construction Standards, Revised January 2013 5.21.30-1
PART 1 GENERAL 1.01 Scope of Standard A. This standard provides general requirements of The University of Texas at Austin for fire pumps. This document is not intended to serve as a guide specification.
Section 02702 SEWER PIPE INSTALLATION AND TESTING
PART 1 - GENERAL Section 02702 SEWER PIPE INSTALLATION AND TESTING 1-1. SCOPE. This section covers the installation and testing of all sewer pipe furnished under the following specification sections: Concrete
How To Clean Up A Reactor Water Cleanup
General Electric Systems Technology Manual Chapter 2.8 Reactor Water Cleanup System TABLE OF CONTENTS 2.8 REACTOR CLEANUP SYSTEM... 1 2.8.1 Introduction... 2 2.8.2 System Description... 2 2.8.3 Component
The work of this Section includes furnishing and installing Reinforced Concrete Pressure Pipe as shown on the Drawings and as specified.
Section 33 0200- Page 1 of 4 PART 1 - GENERAL 1.1 DESCRIPTION OF WORK The work of this Section includes furnishing and installing Reinforced Concrete Pressure Pipe as shown on the Drawings and as specified.
HYDRAULIC LIFT TABLE CART 2200-LB.
HYDRAULIC LIFT TABLE CART 2200-LB. OWNER S MANUAL WARNING: Read carefully and understand all MACHINE ADJUSTMENT AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other
SELF-INSPECTION PROGRAM FOR FIRE PROTECTION EQUIPMENT
SELF-INSPECTION PROGRAM FOR FIRE PROTECTION EQUIPMENT INTRODUCTION No matter how reliable fire protection equipment may seem, periodic maintenance is needed to ensure proper operation. Fire protection
LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459
SECTION 15459 PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division-1 Specification sections, apply to work
SECTION 33 41 13 PUBLIC STORM UTILITY DRAINAGE PIPING
SECTION 33 41 13 PUBLIC STORM PART 1 - GENERAL 1.01 SECTION INCLUDES A. Storm drainage piping, fittings, and accessories at proposed station areas and locations other than under and immediately adjacent
Broad Crested Weirs. I. Introduction
Lecture 9 Broad Crested Weirs I. Introduction The broad-crested weir is an open-channel flow measurement device which combines hydraulic characteristics of both weirs and flumes Sometimes the name ramp
BERMAD Waterworks. Pressure Relief/Sustaining Valve. 700 Series. Model 730. Features and Benefits. Major Additional Features
Pressure Relief/Sustaining Valve Prioritizing pressure zones Ensuring controlled pipeline fill-up Preventing pipeline emptying Pump overload & cavitation protection Safeguarding pump minimum flow Excessive
DESIGN CLARIFICATION (DC)
DESIGN CLARIFICATION (DC) Owner: Victor Valley Wastewater Reclamation Authority Date: 03/03/2015 Contractor: W M Lyles Carollo Project No.: 8299A.20 Project Name: Subregional WRPs DC No.: 001 DC Title:
PART 1 GENERAL 1.1 SECTION INCLUDES
J-1 Section 09110 Long Form Specification INTERIOR METAL STUD FRAMING This section includes lightweight, usually 0.036 inch (0.9 mm) thick or lighter, non-axial load bearing metal stud framing including
Chapter 9 Sanitary Sewers
Chapter 9 Sanitary Sewers S:/Engineering/Design Standards/Chapter 9 12/29/2014 Section 9.1 Topic General Requirements Chapter 9 Sanitary Sewers Page 9-1 9.2 Plan Submittals 9-1 9.3 Determination of Flow
San Antonio Water System Standard Specifications for Construction ITEM NO. 1100 SLIP-LINING SANITARY SEWERS
ITEM NO. 1100 SLIP-LINING SANITARY SEWERS 1100.1 DESCRIPTION: This item shall consist of slip-lining sanitary sewer pipe, which is accomplished by pulling or pushing liner pipe into existing sewers by
SECTION 11014 WINDOW WASHING SYSTEMS
SECTION 11014 WINDOW WASHING SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section includes, but is not limited to, design and furnishing portable davits, davit sleeves, dvit bases, four (4) removable outriggers,
SECTION 05 42 16 COLD-FORMED METAL DECK FRAMING Elevations Steel Deck Framing by Trex
(Specifier Note: The purpose of this guide specification is to assist the specifier in correctly specifying cold-formed metal deck framing products and execution. The specifier needs to edit the guide
5.23.22 STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL. 1.01 Purpose:
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
Drum Dispensing Stations
Drum Dispensing Stations O Safely Dispense from 55 Gallon Drums over a Spill Compliant Sump. 1-2-and 4 drum models available Drums are securely held on racks by galvanized positioners Sump and frame constructed
LOADING DOCK EQUIPMENT. A. Section 03100 - Concrete Forms and Accessories: Placement of anchors into concrete.
LOADING DOCK EQUIPMENT PART 1 GENERAL 1.1 SECTION INCLUDES A. Loading dock equipment of the following types: 1. Dock lifts. 2. Control stations. 1.2 RELATED SECTIONS A. Section 03100 - Concrete Forms and
Float and Thermostatic Traps Series H, C and X
Hoffman Specialty Installation & Maintenance Instructions HS-(E) and Thermostatic Traps Series H, C and X Series C & NPT Series C NPT Series X NPT Series C NPT Series H Ratings Maximum Max. Operating NPT
ELECTRIC/DIESEL FIRE PUMP CHECK LIST
BUILDING NAME: DESIGNER: SCO REPRESENTATIVE: PUMP MANUF.: LOCATION: INSTALLER: DATE: OWNER NAME: INSTALLATION Certificate for flushing and hydrostatic test furnished Piping been hydrostatically tested
Sports and High Mast Lighting Poles Phone: (866) 474-7200 Fax: (817) 924-7049
Sports and High Mast Lighting Poles 4 High Mast Lighting Poles General American LitePole offers a raising and lowering system that allows for ease of maintaining the lighting system at ground level. Ideal
Texas Commission on Environmental Quality Page 1 Chapter 217 - Design Criteria for Domestic Wastewater Systems
Texas Commission on Environmental Quality Page 1 217.31. Applicability. SUBCHAPTER B: TREATMENT FACILITY DESIGN REQUIREMENTS 217.31-217.39 Effective August 28, 2008 This subchapter details the design values
Flygt Ball Check Valves
4/13 Supersedes: 6/96 The basic purpose of a check valve is to permit flow in one direction, prevent flow in the opposite direction and perform this function automatically and with minimum maintenance.
ball valves Flomite 71 Series 2-way Integral Panel Mount Ball Valves
2-way Integral Panel Mount Ball Valves Used for quick on-off service with a visual indication of flow, HOKE s 2-way ball valves offer orifice sizes up to 0.25 (6.4mm). Flomite valves feature a floating
Special Specification 7021 Water Main and Sewer Line Replacements
Special Specification 7021 Water Main and Sewer Line Replacements 1. DESCRIPTION Furnish, install, or replace water pipe, water valves, water meters and boxes, water service connections, fire hydrant assemblies,
CHAPTER 3 STORM DRAINAGE SYSTEMS
CHAPTER 3 STORM DRAINAGE SYSTEMS 3.7 Storm Drains 3.7.1 Introduction After the tentative locations of inlets, drain pipes, and outfalls with tail-waters have been determined and the inlets sized, the next
SECTION 5 DRAFTING STANDARDS
SECTION 5 DRAFTING STANDARDS 1 SECTION FIVE TABLE OF CONTENTS Description Page TABLE OF CONTENTS... 5-2 GENERAL... 5-3 DRAFTING STANDARDS... 5-5 DRAFTING MINIMUM REQUIREMENTS HANDOUT... 5-8 2 GENERAL 1.
VAG Non-Return Valves
VAG Non-Return Valves VAG SKR Slanted Seat Tilting Disk Check Valve Body Shaft Disk Bearing bush Seat Technical details Nominal pressure PN 10 / PN 16 Nominal diameter DN 200...1200 Fields of application:
MONO BLOCK DIRECTIONAL CONTROL VALVE TS1120TSLB
MONO BLOCK DIRECTIONAL CONTROL VALVE TS112TSLB TS TS212TSTSJB P T TS312TSDTSTKJ TS112TSJB FEATURES: O RG PORTS to eliminate leakage. POWER BEYOND CAPABILITY to fit your multi valve circuits. BUILT ANTI-DROP
Jay R. Smith Mfg. Co.
Jay R. Smith Mfg. Co. Automatic Backwater Valve SMITH CUSTOMER DRIVEN FLOOD-GATE FEATURES Index Page Flood-Gate Features and Applications 2 How Flood-Gate Works 3 Flood-Gate Operation & Approvals 4 Valve
STANDARD SPECIFICATIONS SECTION 03461 PRECAST REINFORCED CONCRETE MANHOLES AND MANHOLE BASES. 1. Structure Earthwork: 02200
STANDARD SPECIFICATIONS SECTION 03461 PRECAST REINFORCED CONCRETE MANHOLES AND MANHOLE BASES PART 1 - GENERAL A. Description This section includes materials, testing, and installation of precast concrete
Storm Drainage Systems 11.9-1
Storm Drainage Systems 11.9-1 11.9 Gutter Flow Calculations 11.9.1 Introduction Gutter flow calculations are necessary in order to relate the quantity of flow (Q) in the curbed channel to the spread of
Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version
instrumentation for fluids Electromagnetic sensor Series FLOMID FX Instructions Manual! Conforms with the Pressure Equipment Directive 97/23/EC. 0830 This equipment is considered as being a pressure accessory
Amendment to OPSS 415 (Nov 2008) Construction Specification for Pipeline and Utility Installation by Tunnelling
Engineering and Construction Services Division Standard Specifications for Sewers and Watermains TS 415 April 2013 Amendment to OPSS 415 (Nov 2008) Construction Specification for Pipeline and Utility Installation
SECTION 807 PUMP STATION REHABILITATION
SECTION 807 PUMP STATION REHABILITATION 807-1 DESCRIPTION: Rehabilitation of pump stations shall be defined as the cleaning, removal, repair and/or replacement of any and/or all components including but
Select Radiators Installation Guide
Select Radiators Installation Guide Table of Contents Informational Symbols...3 Before You Begin...4 Select Rough-In... 5 Connection Installation...6 Optional Piping Arrangements...7 Conventional Wall
SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront
PART 1 GENERAL 1.01 Work Included SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS System 402 Flush-Glazed Screw Spline Storefront A. Furnish and install aluminum architectural storefront system
SECTION 02612 NONREINFORCED CONCRETE SEWER PIPE
SECTION 02612 PART 1 GENERAL 1.1 SUMMARY A. Section Includes: Furnishing and installing nonreinforced concrete sewer pipe. Provide concrete sewer pipe less than 12 inches in diameter, and in other sizes
Wastewater Collection System Supplemental Design Standards for Capital Improvement Program Projects
Wastewater Collection System Supplemental Design Standards for Capital Improvement Program Projects March 2013 i Metropolitan Sewer District of Greater Cincinnati Wastewater Collection System Supplemental
SWIMMING POOL HEAT PUMP
SWIMMING POOL HEAT PUMP Installation & User Manual Model HP40B HP50B HP65B Hayward Pool Products Canada, Inc. T: 1-888-238-7665 www.haywardpool.ca CONTENT I. Application 4 II. Features 4 III. Technical
V47 Series Temperature Actuated Modulating Water Valves
V47 Series Temperature Actuated Modulating Water Valves Master Catalog 125 Valves, Miscellaneous (Other Than Gas) Section V Product Bulletin V47 Issue Date 0286 Application The V47 modulating valves regulate
The checklist utilized by the Authority will be similar to that which is shown below. Project Name: Location: Consulting Engineering Firm:
Page 1 of 6 Section 1. PURPOSE This policy is an Engineering checklist of the Local Review Program for sanitary sewer improvement projects by the Bedford Regional Water Authority ( Authority ). Section
P.A.L. S SPECIFICATIONS
PART 1- GENERAL 1.1 SCOPE To furnish all labor, materials and equipment necessary or required to complete the installation of the lift as indicated on the Drawings and Specifications. This specification
City of San Diego, CWP Guidelines
PART 1 -- GENERAL SECTION 08520-1.1 WORK OF THIS SECTION City of San Diego, CWP Guidelines A. The WORK of this Section includes providing aluminum windows with frames, bracing, glazing attachments, screens,
SECTION 1 GENERAL REQUIREMENTS
Page 1 of 6 SECTION 1 GENERAL REQUIREMENTS 1. SCOPE OF WORK: The work to be performed under the provisions of these documents and the contract based thereon includes furnishing all labor, equipment, materials,
DENVER MODEL 30 X 30 SPECIFICATIONS
DENVER MODEL 30 X 30 SPECIFICATIONS Dimensions: Roof Dimensions 30-0 x 30-0 (4) Columns (Center to Center) 25-6½ x 25-6½ Minimum Clearance 8-0 Roof Height @ Peak Dependent on Col. Ht. Hip Roof 4:12 pitch
Belt and Roller Conveyor for boxes and containers
logiss srl 38068 Rovereto (TN) Italy Viale del Lavoro, 16/E (ZI) Tel. +39 0464 401121 Fax. +39 0464 423077 Mail [email protected] Web Belt and Roller Conveyor for boxes and containers A wide range of
PREPIPED LIQUID FUEL MANIFOLDS PLPM
PREPIPED LIQUID FUEL MANIFOLDS PLPM INSTRUCTIONS WARNING These instructions are intended for use only by experienced, qualified combustion start-up personnel. Adjustment of this equipment and its components,
ROOF TOP MOUNTED Air Handler Specification
ROOF TOP MOUNTED Air Handler Specification PART 1: GENERAL (Model RT) Mechanical Specification 1.01 WORK INCLUDED A. Provide complete air handling unit(s) suitable for outdoor installation. Contractor
pvc well casing & drop pipe
CertainTeed pvc well casing & drop pipe PVC Well Products Sure Fit PVC well casing and drop pipe have gained broad acceptance since their introduction almost 40 years ago. Today, due to its outstanding
Standard Hydraulic Piping Flushing Procedure
Page 1 of 6 1.0 Scope This procedure covers the minimum technical requirements for cleaning and flushing of Hydraulic and Piping, and related accessories. 2.0 Introduction In hydraulic fluid power systems,
10 TON HYDRAULIC PRESS
10 TON HYDRAULIC PRESS Model Nos. CSA10F and CSA10B OPERATING & MAINTENANCE INSTRUCTIONS 0200 SPARE PARTS and SERVICING Please contact your nearest dealer, or CLARKE International, on one of the following
HYDROMATRIX Jebel Aulia - Sudan
HYDROMATRIX Jebel Aulia - Sudan www.andritz.com HYDROMATRIX - Concept Jebel Aulia - Sudan HYDROMATRIX is a new concept of hydraulic energy generation, which has been developed by an American engineer in
MONO BLOCK DIRECTIONAL CONTROL VALVE TS
SHIPPING: 2332 S 25TH STREET (ZIP 6815) MAILING: P.O. BOX #669 OMAHA, NE 6816 PHONE: (42) 344-4434 FAX: (42) 341-5419 HTTP://WWW.BRAND-HYD.COM MONO BLOCK DIRECTIONAL CONTROL VALVE TS TS312TSDTSTKJB TS2
Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description
Product Manual CVS Type 67AFR Filter Regulator Introduction This CVS Controls product manual includes instructions for the installation, adjustment, maintenance and parts ordering of the CVS Type 67AFR
Roped Hydraulic Residential Elevator Specifications
January 1, 2004 Roped Hydraulic Residential Elevator Specifications P.O. Box 749, 5191 Stump Rd., Plumsteadville, PA 18949 Toll Free: 888-443-2800, Phone: 215-766-3380, Fax: 215-766-3385 CONTENTS Part
SECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS
SECTION 15750 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for roof mounted, self-contained units, with electric cooling, and electric or reverse refrigeration cycle (heat pump) heating
Power consumption (kw)
OS Series Series description LIT OS systems are applied to wastewater disinfection. The models of this series were developed on base of high-efficiency low-pressure amalgam lamps and have all components
COUNTERBALANCE VALVES
COUNTERBALANCE VALVES Introduction They are modulating valves which allow free flow into the actuator and then block the reverse flow until they feel a pilot pressure inversely proportional to the load
Installation Manual DIAPHRAGM WELL TANK
Installation Manual DIAPHRAGM WELL TANK Safety Instructions Installation Warranty IN-LINE SERIES: 2-5 & 7 GALLON HORIZONTAL SERIES: 7-14 & 20 GALLON VERTICAL SERIES: 14-20-32-36-52-86-96-119 GALLON KEEP
CHAPTER 6 - SANITARY SEWER
CHAPTER 6 - SANITARY SEWER 6.1 GENERAL This section covers the requirements for PVC plastic sewer pipe materials and installation in sanitary sewer construction. 6.2 PIPE PVC gravity sewer pipe and fittings
Index 11.1. Page. Pumping Systems...11.2-11.4 Intensifiers...11.5 Gas Boosters...11.6-11.7 High Pressure Generators...11.8-11.9
Pumping Systems, Intensifiers, Gas Boosters and High Pressure Generators High Pressure Equipment Company produces a number of components and systems for general industrial, elevated pressure applications.
DIVISION OF WATER QUALITY CONSTRUCTION GRANTS & LOANS SECTION FAST TRACK AUDIT CHECKLIST
DIVISION OF WATER QUALITY CONSTRUCTION GRANTS & LOANS SECTION FAST TRACK AUDIT CHECKLIST CERTIFICATION 1. Did the engineer submit a certificate of completion utilizing the appropriate page of the issued
VdS 2100-09en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS 2100-09en : 2011-05 (01)
VdS Guidelines for water extinguishing systems VdS 2100-09en Requirements and test methods VdS 2100-09en : 2011-05 (01) Publishing house: VdS Schadenverhütung GmbH Amsterdamer Str. 172-174 50735 Köln,
2010 Residential Water Heater Replacement Check List
2010 Residential Water Heater Replacement Check List The intent of this check list is to provide installers a general reference for the enforcement of code requirements in the Greater San Diego Area. This
SECTION 6 SANITARY SEWER MAIN 6.01 SCOPE
6.01 SCOPE The work covered by this section of the specifications consists of the furnishing of all plant, labor, materials, equipment and supervision and performing all operations involved in the construction
The Piping System Model a New Life Cycle Document. Elements of the Piping System Model
Piping System Model as a Life Cycle Document White Paper Introduction When designing piping systems, a variety of documents are created providing the details necessary to design, purchase, build, and test
DIVISION 2 - SEWERAGE AND DRAINAGE SECTION 02720 - STORM DRAIN SYSTEMS PART 1 - GENERAL
DIVISION 2 - SEWERAGE AND DRAINAGE SECTION 02720 - STORM DRAIN SYSTEMS PART 1 - GENERAL 1.01 DESCRIPTION A. Furnish and install all storm drains, including manholes, inlets, service lines and other appurtenant